Deesys Total Products Guide: Digital Power Protective Relay
Deesys Total Products Guide: Digital Power Protective Relay
디지털
Digital 전력보호
Power 계전기기
Protective Relay
Venture Company
KEPCO Venture
Digital Multi-Power Protective Relay
Nuclear electrical Power Quality Meter
Manufacturer’ s
Communication for Electrical protection System
ISO9001 - Digital Protective Relay
KSA9001
Digital Type Protective Relay
KSC 1303: Panel Meter Marine Type Protective Relay
KSC1706 : C.T/P.T
Digital Earth Leakage Detector and Relay
Korea Fire Equipment
Inspection Corp.
Earth Leakage Ground Fault Relay
Low Voltage Zero Phase Sequence Current Transformer
Germanischer
Lloyd Motor Protective Relay
Induction Type Protective Relay
TUV Product Service GMBH
Panel Board Meter
JIS C 1102
Current and Voltage Transformer
Insulator
Korean Agency for
Technology and Standards
DEESYS
TOTAL PRODUCTS GUIDE
Digital Power Protective Relay
인사말
Introduction
디이시스(주)는 전력보호계전기기 전문 생산업체로 D2K Series 라는 각종 Digital 계전기 및 집합형 누전경보기를 국내 최초로 개발 완료하여 특허출원을
완료하였습니다. 최근 전기 누전으로 인한 화재 및 인명, 재산의 피해를 사전에 예방하여 주는 소방법을 근거로 개발된 Digital 계전기 및 누전경보기 제품
은, 산업발전에 따라 전기 사용량이 증대되고 전력계통이 복잡 다양화 됨에 따라 전기로 인한 재해가 증가되고 있는 시점에 전력보호계전기기의 기능을
Up-grade하여 기기 한 대로 8회로에서 32회로까지의 다양한 모델을 선택함으로서 설치 면적을 최소화 하였으며, 기존의 기기와도 호환이 가능하여 개
보수 비용이 절감될 수 있는 획기적인 제품입니다. 기능, 설치, 운영면에서 보면, 현재 변전소의 무인화 및 원격 감시 시스템에 적용되고 있으며, 고기능
화 및 정보 전송의 간소화 등의 기술적 발전을 이룬 차세대형 배전감시 Digital 보호계전기기로서 최근의 수요, 공급의 확대로 많은 건축물의 전기사고로
인한 피해로 부터 인명, 재산을 보호하는 큰 역활을 담당하고 있습니다.
연혁
History 수상실적
Awards
79. 3대연전자 주식회사 창립 86. 9 유망 중소기업 선정 제일은행
79. 7소방용 기계기구 제조허가 취득 92. 2 신기술개발표창 한국전기공업협동조합
82. 6제조업 허가 96. 5 품질관리대상수상 한국소방검정공사
86. 9유망 중소기업 선정 97. 2 우수 수출업체 표창 한국전기공업협동조합
88 10
한국 전기공업 협동조합 가입 98. 3 조세의 날 표창 경인지방국세청장
91. 4한국 전기공업 진흥회 가입 98. 5 수출 및 신기술 개발표창 산업자원부장관
92. 5계량기 제조업 허가 취득 98. 9 유망 VENTURE 기업 선정 경기지방 중소기업청
한국 산업기술진흥회 가입 99. 1 기술경쟁력 우수기업 선정 중소기업청
94. 1 계전기 말레이시아 및 동남아시아 수출 00. 5 유망 전력 VENTURE기업 선정 한국전력공사
4 일본 Mitsubishi(주) 부품 공급계약 체결 00. 11 2000년 전기공업 수출부문 수상 국무총리
10 김포공장 신축 준공-본사 및 공장 01. 10 2001년 전기공업 수상 산업자원부장관
96. 3 기업부설연구소 설치 02. 7 수출 및 신제품 개발표창 행정자치부장관
97. 3 복합형 전력용 변환기 개발 (한국전기연구소)
97. 12 DIGITAL 과전류 및 지락과전류 계전기 개발
99. 7 대한전기학회 특별회원 (대한전기학회)
00. 4 상호변경 대연전자(주)→디이시스(주)
01. 1 NPTC 한학연 회원사
5 변성기 공장 신축
02. 5 일본 KAWAMURA 전기(주) 수출공급
03. 4 대한전기협회 회원 가입
04. 4 대표이사 변경 (대표이사 유병국)
07. 2 디지털 계전기 개발 출시
인증현황
Certificate
80. 3 누전경보기(ELD, ELR) 형식승인 한국소방검정공사 02. 5 EM우수품질인증 기술표준원
93. 3 KS C 1303 지시전기계기인증 한국표준협회 03. 11 CE 인증(디지탈 복합형계전기 EMC) TUV(독일)
95. 4 ISO 9002인증 한국품질인증원 04. 3 CE 인증(디지탈 복합형계전기 안전 TUV(독일)
97. 6 ISO 9001인증 한국생산성본부
98. 7 ELD, ELR 신제품 형식승인 한국소방검정공사
98. 9 원자력 (KEPIC-EN) 자격인증 대한전기협회
99. 9 KS C 1706 계기용 변성기 인증 한국표준협회
99. 1 GL선급협회 PFR인증 GL선급협회(독일)
00. 5 CE 인증(디지탈 계전기) TUV(독일)
01. 6 디지털 누전경보기 형식승인 한국소방검정공사
02. 3 JIS C 1102 지시전기계기인증 본공업규격
인증서
Certification
Digital Electric & Electronic system
누전경보기, 지락계전기
Analog Type ELR, GFR
과전류 및 지락과전류 계전기 OCR & OCGR 재폐로 계전기 Reclosing Relay
Digital Electric & Electronic system
유도형 전력보호계전기
Induction Protective Relay
지시계기 메터
Panel Board Meter
모터 보호 계전기
Motor Protective Relay
4E 모터보호계전기 3E 모터보호계전기
디지털형 전력보호 계전기
Digital Type Power Protective Relay
전력용 직류 / 교류 변환기
Power transducer
단품형 변환기
Single Type Transducer
※진동이 많은 장소에서 사용되는 경우 제품의 일부 부품이 공진이 발생되어 �단자BOLT는 적절한 공구에 의한 적합한 토크로 단단히 죄어
주세요.
소손될 우려가 있으며, 또한 오차나 기기변동이 발생할 경우가 있으므로, 방
M4나사 : 0.98~1.47N/m
진처리를 하거나 설치장소를 변경하시기 바랍니다.
■설치에 관한 사항
●제작을 오랜기간 바르게 사용하기 위해서는 일상점검을 하십시오 ●장시간 보관하는 경우는 다음과 같은 장소를 피해주십시오.
�제품에 손상이 없는가? 고장 및 명단축의 원인이 될수 있습니다.
�동작이나 지시에 이상(입력에 대응하지 않는 동작이나 지시) �주의 온도가 -20~60℃의 범위를 넘는 장소.
이 없는가? �일평균 온도가 35℃를 넘는 장소.
�설치 또는 단자대의 결선에 느슨함이 없는가? �습도가 90% RH 이상으로 결로하는 장소.
※감전을 방지하기 위해서는 반드시 정전상태에서 행해주십시오. �먼지, 폐식성가스, 염분, 연기가 많은 장소.
�진동, 충격이 많은 장소.
●COVER는 대전방지처리를 했으므로 청결유지는 다음 사항을 �비, 수분, 자외선, 일광이 직접 닿는 장소.
지켜주세요.(특히 지시전기계기)
●관리는 전원을 끄고, 배선을 빼고, 비닐 봉투나 상자등에 넣
�덮개표면의 더러운 것은 부드러운 헝겊으로
어서 보관하시기 바랍니다.
가볍게 두들겨 제거하십시오. 또, 심하게
더러울 경우는 교환을 하는 것이 좋습니다. ■ 폐기에 관한 사항
D2K-MPRO
Digital Multi-Power
Protective Relay
■ Intelligent Electronic Device
[OCR 50/51, OCGR(50/51N), UVR(21), OVR(59)
OVGR(64G), SGR(67G), DOCR/DOCGR(67N)]
D2K-MPRO
전자화 배전반 종합 보호 계전기
D2K-MPRO Digital Multi-Power Protective Relay
MODEL D2K-MPRO
특징 Features
MPRO는 고신뢰성의 디지털 보호계전기능, 정밀한 계측기능 및 차단 MPRO is a IED(Inteligent Electronic Device) that provides a
기 제어기능을 수행하고, 중앙감시시스템과의 다양한 인터페이스를 통 solution for high reliable multi purpose digital protective relay,
한 원방감시제어가 가능하며 고기능의 전자식 배전반 Solution을 가능 precise measurement and circuit breaker controls, remote
하게 하는 IED(Intelligent Electronic Device)입니다. 또한 직접접지 controls interfacing with a central detective system, and a high
또는 비접지 계통에서도 적용되며 중소용량의 발전소가 연계된 계통에 performance distributing board. This works with or without
서 방향성(Directional OCR) 선택/동작시도 적용할 수 있습니다. grounding, or directional OCR in a small power plant.
Specificatain
사용주파수 50/60(Hz)
CT 5(A)
정격 전류
ZCT(1차/2차) 200/1.5(mA)
PT 100(V)
정격 전압
GPT 190(V)
AC/DC 110~250(V)
상 태입력 2.5VA 이하
사용온도 -20~60℃
사용 온도
사용온도및 습도 보관온도 -25~70℃
습 도 일평균30~80%
절연 저항
뇌 임펄스 내전압
과부하 내량 IEC60255-6규격 적용
1MHz Burst
내환경 성능 Electrostatic Discharge
IEC60255-22, IEC61000-4
EMC Fast Transient 규격 적용
Sureg
RF Interface
EMI IEC60255-22-3규격 적용
진동 및 충격 EC60255-22-3규격 적용
Front plate
Operation status
- Run
- System fail
Local/Remote mode
User interface(Terminal Port) - LED or button
- RS-232C
- Optical port(option)
Power On/Off button
- On(red)
Communication status User function key - Off(green)
- display communication - measured data display
status with mater (refer - relay setting
to the back) - communication parameter setting
- Tx(green)/Rx(red) - event setting
- addition function setting
� I -1K �+ C ×
T= a
tp
10
a K C
Specificatain
동착치 동작시간
계전기능 동작구분 특성
설정범위 설정단위(Step) 설정범위(Lever) 설정단위(Step)
순시 5~80A, Block �
1 A� 40ms 이하
OCR 반한시, 강반한시
(50/51) 한시 0.2~16A. OFF 0.1
�A� 0.2~50.0 0.2 초반한시
*정한시
순시 3~40A. OFF 0.5
�A� 40ms 이하 순시
OCGR 반한시, 강반한시
(50/51N) 한시 0.2~5A. OFF 0.1
�A� 0.1~50.0 0.2 초반한시
*정한시
순시 5~80A. OFF �
1 A� 40ms 이하 순시
반한시, 강반한시
한시 0.2~16A. OFF 0.1
�A� 0.2~50.0 0.2 초반한시
DOCR
*정한시
기준위상각 0~90(1。
단위 설정)
동작위상각 ±60~±90(1。
단위 설정)
UVR(27) 한시 (0.1~1)×110
�V� 1.0
�%� 0.2~50.0 0.2 반한시, 정한시
OVR(59) 한시 (1.1~1.4)×110
�V� 1.0
�%� 0.2~50.0 0.2 반한시, 정한시
OVGR(64) 한시 (0.05~0.4)×190
�V� 1.0
�%� 0.2~50.0 0.2 반한시, 정한시
전류 1~10
�mA� 0.1
�mA�
0.2~50.0 0.2 정한시
SGR 전압 (0.05~0.4)×190
�V� 1.0
�%�
(67G) 기준위상각 0~90(1。
단위 설정)
동작위상각 ±60~90(1。
단위 설정)
순시 3~40A. OFF 0.5
�A� 40ms 이하 반한시, 강반한시
DOCGR 한시 0.2~5A. OFF 0.1
�A� 0.1~50.0 0.2 초반한시 *정한시
(67N) 기준위상각 0~90(1。
단위 설정)
동작위상각 ±60~90(1。
단위 설정)
Characteristic Curves
Control
제어출력 출력단자 용량 비고
Communication
통신 Protocol
∙DNP3.0 Eather-net (TCP/IP)
∙ModBus
∙IEC60870-5
∙LonWorks
∙BACnet
Metering
계측사양
표 시 오 차 비 고
Load Profile
항목 관리 전기량 기록용량
Fault Memory
운전정보기록
항목 관리데이터 기록용량
고장 파형 데이터 고장 발생 시각 최근 고장 파형 4회
각 상전류, 전압 파형 (128Cycle 샘플 데이터/1회)
영상전류, 영상전압 파형
Menu Specification
표준 RS-232C 사용
통신속도 : 9,600 - 38,400bps 설정가능
● 계측치 / DI 상태표시
● 차단기 상태표시
● Polling주기 조절에 의한
자동 갱신기능
● 에러 및 통신상황 표시
● 통신 Transaction View
● 설정 계전기 동작 특성 확인
● 입력 신호에 따른 동작시간 계산확인
● 동작 시간 배수 변경
● 동작 특성 변경
● 계전요소별 설정값 표시
● 설정치 자동 갱신
● 설정치 변경 화면 활성
● 계전요소별 설정값 변경 기능
● 기본 설정값 복원 기능
● 설정 최대 및 최소값 준수
Menu Specification
● 최근 고장의 상세 정보 표시
● 실시간 자동 갱신 기능
● 고장파형 선택
● 파형 읽기/삭제
● 고장파형 파일 저장 기능
● 고장파형 분석
● 고장정보 표시
● 영역별 탐색/확대 기능
● 파형별 컬러 지정
● 파형 복합 기능
● 채널 선택 기능
● 2개 이상의 파형 비교 기능
Wiring
EXternal Wiring(3P4W)
EXternal Wiring(3P3W)
Dimension
Front View
Side View
Cutting View
Rear View
D2K-MNET
Power Quality Meter
■D2K-MNET Power Quality Meter
D2K-MNET
원격 감시제어용 종합메터
D2K-MNET Power Quality Meter
Introduction
D2K MNET
D2K MNET은 전형적인 Power Meter를 뛰어넘어 혁신적으로 디자인 되었으며, 컨셉화 되어졌습니다. 또한 D2K MNET은 작아지고, 전자적으로
진보했으며, 프로그램이 가능한 종합 측정 장비입니다. D2K MNETⅢ는 미래의 전기적 측정방법의 여러가지 요구에 대한 해답이 될 것입니다.
D2K MNET의 Concept은 몇가지 아래와 같은 원칙을 기본으로 디자인 되었습니다.
Parameters Conversion
Microprocessor가 내장된 D2K MNET은 modicon사의 Modbus� 시스텀을 기본으로 제공합니다. 이는 제품의 정보 표시창으로부터 읽어들일
수 있는 30가지 이상의 정보보다 더 많은 90가지 이상의 정보를 PC를 통하여 감시 제어 할 수 있는 기능을 제공합니다.
Features
● 90가지 이상의 전력 및 에너지 정보표시 ■ 0.15% 이내의 오차
● 공장과 건물의 자동화 ■ 최대 수요전력의 통제
● Modbus protocol 탑재 ■ 모든 셋팅값과 데이터의 저장
● 최대 600V 사용가능 ■ 광범위한 Selftest
● True RMS 변화가능 ■ Low input burden 0.1VA (5A /120V)
● 순시 최대값, 최소값 표시기능 ■ 폭넓은 제어전원 사용 (80~260V AC/DC)
● 선명하고 긴 수명의 VFD채용 ■ 간략화된 제품의 구성
● RTC 내장(Real Time Clock) ■ DIN & ANSI 에 적합한 Cutout
● P.T / C.T 비율 설정가능 ■ 2kV RMS input / output / power 의 절연
● Factory & Building Automation (FA & BA) ● Memory for all setup and energy data
D2K MNET은 AC Switch-gear 혹은 공장 전력분배 시스템에 광 전원공급이 중단되어도 D2K MNET은 측정된 Wall-Hopur, 최대
범위하고 쉽게 적용이 가능하여 공장과 건물의 자동화로의 발전을 수요전력, 날짜와 시간, PT/CT비, 시스템설정값, 표시설정값, 통신
도와줍니다. 관련 데이터등의 모든 값을 메모리에 저장하여 안전하게 보관합니
● PLC Modbus Compatible 다.
Modbus communications protocol 은 D2K MNET과 ● Field Programmability
Programmable Logic Controller(PLC) 혹은 다른 thirdparty 의 D2K MNET은 CT/PT비, Modbus @ address, 통신속도, parity,
Modbus 호환 모니터링 프로그램, 컨트롤 시스템간의 데이터를 효 display등을 전면의 버튼을 이용하거나 통신포트를 이용하여 PC에
율적으로 변환합니다. 또한 IPC-based centralized master 서 현장의 조건에 맞도록 설정이 가능합니다.
display software 를 쉽게 채용할 수 있는 모니터링 시스템을 채용 ● Accuracy up to 0.15%
하였습니다. 더욱 발전된 conversion,“ sampling 그리고 software 보상기술
● Built-in Real Time Clock 로 전압과 전류는 0.15% 이하, 전력은 0.25%이하의 오차율을 실현
D2K MNET은 실시간 타이머(Real Time Clock)를 내장하여 최대/ 하였습니다. PC를 통하여 감시 제어할 수 있는 기능을 제공합니다.
최소 에너지값을 기록할 수 있으며, 수요전력 Sampling(Display)
Time을 설정 할 수 있습니다. (15/30Minute)
DMM -5.0A - H - 1 - 1
Wiring
1 : 1P2W
Current Input 2 : 1P3W
1.0A 3 : 3P3W
5.0A 4: 3P4W
Specification
● Accuracy : Corresponding to each auto-range scale ● Accuracy performance range for WH / VarH / PF
● VL1 / VL2 / VL3 : Line to line voltage Cos Θ : 1-0.5 for WH / PF
VP1 / VP2 / VP3 : Line to neutral voltage Sin Θ : 1-0.5 for VarH
● PF1 / PF2 / PF3 : Related conversion elements Voltage � 75V, Current � 0.5A
● IO (neutral current, only for 3 phase 4 wires) ● Phase rotation
SEQ POST : positive sequence
SEQ NEG : negative sequence
RTC
● Burden
Maximun deviation 5 sec in 24 hours
Voltage < 0.4VA at 600V
Time for year / month / date / hour/ minute / sec
< 0.04VA at 150V
Current < 0.1VA at 5A
Dielectric strength
IEC 255-5
Overload rating
2KV AC rms 1 minute between input / output /power
Current voltage
2 X rated continuous 750V continuous
Impulse and surge test
10 X rated 30 seconds 1000V 10 seconds
ANSI / IEEE C37.90.1-1989(3KV) SWC test
25 X rated 2 seconds 1200V 3 seconds
IEC 255-22-1 class III SWC test
50 X rated 1 sceonds
IEC 255-22-4 class Ⅳ (IEC 801-4) SWC test
IEC 255-5 1.2 50us (5KV) impulse test
Measured system
● Suitable for 3 phase 4 wires / 3 phase 3 wires/ single
Stability
phase 2 & 3 wires / 3 phase balance
Temperature range - 24 to +55 ?C
● Select by input wiring & software configuration
Maximum 100 ppm / ?C
Long term stability 0.15% drift maximum per year
Programmability
● Software accessible / password lock
Operation condition
● System selection :
Temperature range - 25 to + 60 ?C,
3 phase 4 wires/ 3 phase 3 wires /
RH 20 - 95% non-condensed
1 phase 2 & 3 wires / 3 phase balance
● PT: 1 - 5000.0 ; CT : 1 - 2000.0
Power supply
● Readout display control
AC 80-260V, 40-70 Hz, DC 80 - 330V
5 or 4 digit / auto scan or manual selection / scanning
DC 20-60v (option)
time
Dissipation maximum 12VA for AC and 6 watts for DC
● Maximum demand 1 - 60 min
● Maximum and minimum of instant measurement
● Communication
baud rate 1200/ 2400/ 4800/ 9600/ 19200
parity (even or odd) / None
Address setting 1 -254
● Calibration
software with password lock
● Memory
all of energy date and status setting
The D2K-MNET PC TOOL a utility program that can help user to connect to“D2K-MNET Power Meter”rapidly. The D2K-MNET PC
TOOL, provided with every D2K-MNET meter , allows easy access to all meter setup information and actual values via a personal
computer running Windows 95/98 and one of the PC’s communication ports-COM1 or COM2. The user can:
HC 6000
SCADA DCS System PC Tool
System PLC
RTU
Test set
Communication Wiring
Computer
RS485
D- D+
Ground shield at SCADA/
Up to 32 devices, PLC/Computer only
maximum 4000 feet (one end grounding) Shield
ZT(*)
R
R = 120 ohm
C C = 1000pF
3 Phase 3 Wires Unbalance Load 1 Phase 2 Wires / 3 Phase 4 Wire balance Load
AS AL BS BL CS CL PA PB PC PN FG Power AS AL BS BL CS CL PA PB PC PN FG Power
_ _
+~ - +~ -
L1 L1
L2 L2
L3
Source Load Source Load
3 Phase 3 Wires Balance Load (1) 3 Phase 3 Wires Unbalance Load (3CT)
AS AL BS BL CS CL PA PB PC PN FG Power AS AL BS BL CS CL PA PB PC PN FG Power
_ _
+~ - +~ -
L1 L1
L2 L2
L3
L3
Source Load Source Load
AS AL BS BL CS CL PA PB PC PN FG Power
Standard Option
_
+~ -
D+ D- Com RxD TxD SG
L1 RS485 X Y Z RS232 X Y Z
L2
Load
L3
Source
Communication for
Electrical Protection system
-Digital Protective Relay
■3 Phase Digital Over Current and Earth Fault Relay [50/51, 50N/51N]
D2K-OG50
과전류 & 지락과전류계전기
D2K-OG50 Series 3-Phase Over Current and Earth Relay[50/51,50/51N]
MODEL D2K-MOG50
Features
Display Mode
Monitoring and Protocol
각 상의 현재 상태전류를 기준으로 하여 A, B, C, N상의 전류상태 사고파형을 저장함으로서 Event Monitoring이 실시간 가능합니다.
를 실시간으로 LCD(Liquid Cristal Display)표시창에 표시합니다. Digital Relay는 Setting Range가 광범위하여 어떠한 상황에서도
정정이 가능하고, 자동화 설비를 위하여 DNP3.0 또는 호환 및 신
뢰성이 높은 Modbus 프로토콜을 적용 하였으며 수용가 요구시 제
공됩니다. 이 계전기는 수용가의 목적에 따라 기능 및 정정 범위를
변경하여 공급 할 수도 있습니다.
Keypad and Communication Fault Event Monitoring
모든 정정치 및 Data는 전면부의 Keypad 또는 RS 232 Port로 PC Fault Event 파형을 72Cycle까지 저장 할 수 있어 사고 분석을 용
와 연결하여 Control 할수 있으며, 후면의 RS485 Port를 이용하여 이하게 하고 특히 무인화 시스템에 적용됩니다.
중앙 Control system에서도 릴레이의 모든 기능을 점검 할 수 있
습니다.
Fault Memory [Memory view]
사고 Data의 횟수는 10회까지 Memory한다.
∙Fault current
∙Fault time
∙Fault phase
∙Fault date
∙Fault type
Eather-net (TCP/IP)
통신사양
통신속도(Comm Speed) : 19,200bps
통신거리(Comm Length) : 1.2km
통신방식(Comm Port) : RS232/485
최대노드수(Max. node) : 64Set
Read Write
�Current display(pr.se) �Current set
�Setting position �Time Lever set
�Fault current(se) �CT ratio(pri/sed)set
�Fault time �Frequency set
�Fault phase �Operatung curve set
�System state check �Communication set
�Date and time
Specification
Model ▶D2K-OG50
Part Name OCEF Three Phase - Over Current and Earth Fault Relay
Model D2K-OG50
Standard code IEC 255, KEMC 1120, and KEPCO
Element Overcurrent (50/51) 3Phase, Earth Fault(50N/51N)
Aux. power AC 110/120V and DC 110/125V ±30%, 9W(Non oper) 16W(Oper)
Rating AC 5A, 50/60㎐
Burden OC/EF 0.3VA
Overcurrent : 0.2~15A(0.1A step)
OC Instantaneous : 5~80A (1A step)
Time lever : 0.1~15(0.1 step) Inst Time 40ms
Setting range
Overcurrent : 0.1~5A(0.1A step)
EF Instantaneous : 3~40A (1A step)
Time lever : 0.1~15(0.1 step)
장강반한시(LT-VI), 반한시(N-IN), 강반한시(V-IN), 초반한시(E-IN) IEC std.
Time curve
반한시(NIES), 강반한시(VIES) KEPCO std.
Resetting value Set of > 95%
Reset time 50ms±25ms
Degree protection IP52
Short current 80 In
Communication RS232(Front view), RS485(Reare view)
Key-pad Mode, ESC, Enter, Direction Key(�,�,�,�)
RUN(Green) : C.P.U Error 동작상태 감시 및 전원감시
COMM(Yellow) : 깜박일때 신호 출력 중
Indicator Pick-up(Red) : Pick-up 과부하 동작시 점등
ERR(Red) : 내부회로 및 소자 불량시 점등
R.S.T.N : 동작 상표시 INST : 단락상태 표시등
10회 Memory 기능 및 사고선로별 회로표시 (선입선출방법,“1”
이 최근 사고를 뜻함
Fault Memory
Memory event recording time 1.2sec
Reset Auto Reset, Indicator(Manual Reset)
Operating temperature -10~60℃
Temperature
Storage temperature -20~70℃
Mounting Flush mounted type
Make AC 250V 15A 0.5sec(L/R=0), DC 125V 30A 0.5sec
Contact capacity
Break AC 250V 3A 0.5sec(L/R=0), DC 125V 30A 0.5sec
Main trip 2a CPU Error : SCADA 1a, alarm 1a
Output capacity OC과부하 : SCADA 1a, alarm 1a OC단락 : SCADA 1a, alarm 1a
EF과부하 : SCADA 1a, alarm 1a EF단락 : SCADA 1a, alarm 1a
Life time 기계적 수명 : 10×106 / 전기적 수명 : 2×105
Withstand voltage 2㎸ for 1minute between all terminal
Lightning impulse withstand voltage 1.2㎲/50㎲ 5㎸ Positive/Negative electrodes, 3times
Surge transient 2.5㎸/1㎒ (IEC255-4)
Electromagnetic fild 5W transceiver 150㎒-400㎒/0.3m (IEC 1000-4-3 c1.2)
Transient Bust immunity Aux. power. contacts. current-4㎸ (IEC 255-22-4)
Electrostatic discharge 8㎸ in air, 6㎸ by contacting
Vibration Vibration frequency : 16.7㎐ Double amplitude:0.4㎜ Direction:horizontal, vertical, transverse
Shock acceleration : 50G Shock application direction:horizontal, vertical, transverse
Shock
Shock times : 3 times
Front View
LED Indicator
Display CPU(RUN)Error check & Aux.
General Setting Power
Level Setting point Pick-up indicator
Fault check System Error indicator
Communication Fault indicator
Self test mode Comm. conection indicator
Menu Specification
Start on display Fault Check Mode
�CPU RESET S/W를 입력하거나 전원을 ON/OFF 하면 초기상태가 Fault current, time, phase
됩니다. �[MEMORY VIEW] Mode가 나올때까지 MODE Key를 입력합니다.
Setting View
�[Setting view] Mode가 나올때까지 Mode Key를 입력합니다.
표시기능
Pickup LED
OC 또는 EF 요소중 전류치가 정정값에 접근하면 이 PICKUP LED가
깜박거리고 지속으로 켜지면 아래와 같이 Display합니다.
(OC-A Phase)
RUN LED
AUX, Power가 정상적이면 녹색 LED가 점등됩니다.
ERR LED
SYSTEM에 이상이 있거나 CPU ERROR가 발생하면 점등됩니다.
COMM LED
외부 기기와 접속하여 통신중 일때 점등됩니다.
이 계전기는 7가지의 반한시 요소, 정한시 요소를 내장한 계전기로 특성 선택시 다음과 같이 선택 할 수 있으며 국제규격 IEC표준과
KEPCO 사양을 채택 하였습니다.
6
A ∙LT-VI(장강반한시)=
I
×Tap (IEC)
( )-1
Ip
0.11 Tap
B ∙N-IN(반한시)= (
I 0.02
+ 0.42 )×
10
(KEPCO)
( ) -1
Ip
39.85 Tap
C ∙V-IN(강반한시)= (
I 1.95
+1.084 )×
10
(KEPCO)
( ) -1
Ip
0.24
D ∙N-IN반한시)= (
I 0.4
+0.12 )×Tap(IEC)
( ) -1
Ip
1.6
E ∙V-IN(강반한시)= (
I
+0.04 )×Tap(IEC)
( )-1
Ip
8
F ∙E-IN(초반한시)=
I
×Tap(IEC)
( )-1
Ip
G ∙DT(정한시) = Tap(IEC)
Tap:Time lever, I:Fault current(CT 2’
ry), Ip:Current set. value
Wiring
Terminal arrangement
Dimension
Digital Protective
Relay
■Reclosing Relay [79]
D RC-O41
자동재폐로계전기
Reclosing Relay[79]
Feature
The auto-reclosing relay is designed with micro processor
based electronic CPU. Which can be applied for any
distribution line either coordinating with synchronizing relay or
bus voltage supervising relay. As setting range is wide, the
reclosing relay may coordinate with other protective relay or
system easily. Since the relay has a self checking funtion. It
can be shown the error message on the front plate of the
relay as soon as detected. There is a delay timer with which
discrepancy time between main and aux. contact of circuit
Specification breaker can be adjusted.
Model Application
�DRC-041(Draw out type) The relay is applied for 3 phase reclosing system up to
154kV transmission network. The relay has input for
Rating synchronizing relay or bus voltage relay where need for
�Aux. Power : DC110/125V(+100%, -20%) network operation or bus voltage supervision.
Setting Range Insulation
�Prepare Time : 30+(5, 10, 20, 40, 75) ∑ (5Sec step, �2kV, 50/60Hz for 1Min
30~180Sec) �Between all terminals Connected for together and Earth
�Reclaim Time : 20+(10, 20, 40, 80, 130) ∑ (10Sec step,
20~300Sec) Impulse Withstand
�Waiting Time : 1, 2, 3, 4, 5, 8, +∑ (1Sec step, 1~20Sec) �5kV, 1.2/50㎲
�T1 Time : 0.1, 0.2, 0.4, 0.8, 1.5, +∑ (0.1Sec step, 0~3.0Sec) �Between all terminals Connected for together and Earth
�T2 Time : 1, 2, 3, 4, 8, 15 +∑ (1Sec step, 0~30Sec) Time Chart(four times reclaim success)
�T3 Time : 5, 10, 15, 30, 60 +∑ (5Sec step, 0~120Sec)
Input Contact
�25-a : Synchro Relay (Normal "a")
�M/L : Manual Locking
�63CB : Circuit breaker Pressure
�50/51-a : Relay Contact
�43RC : Reclosing switch ON/OFF
�CB-a : Circuit breaker“a”Contact
Output Contact
�79B : OTLC Blocking
�79M : Reclosing signal (During Reclosing pulse with)
�79S : 50 Relay Blocking (During Reclosing pulse with)
�79C : Relay Error (C.P.U, Power)
�79F : Lock out (Fail) Continuous
Counter Indicator
�Cumulative number of reclosing Commands, up to 999
적용 Application
이 3상 일괄 투입형 자동 재폐로 계전기는 154급 이하 방사상 선로에 The three phase auto-reclosing relay is for radial
사용할 수 있으며, 동기 계전기와 조합하여 동기 조건이 맞을 경우 투 transmission line below 160kv system. It can be
입 할수 있는 기능도 내장되어 있습니다. 동기 조건이 필요 없는 선로 coordinated with synchronizing relay for check live-line
and live-bus or voltage detecting relay for main bus
에서는 모선전압 감시 계전기와 조합하여 모선이 이상 없을 시 투입 voltage.
조건을 만족하도록 하는 기능으로 사용됩니다.
명판 Front plate
-기능 다이얼 : 정상 운전시 이 다이얼은 COUNT에 놓습니다. 릴레이 - Menu Dial : The dial pointer will be set at COUNT for
가 동작하면 동작 횟수에 따라 1st LED/ 2nd LED/ 3rd LED 순으 normal use. Accumulated reclosed times are summed on
로 켜집니다. 이 LED는 RESET을 누르면 꺼집니다. Pt-Rt-Wt-T1- the display While reclosing is performing. 1st LED-2nd
LED-3rd LED is/are lighted in order whenever succeeding.
T2-T3 순으로 돌리면 그 위치에서 Setting 값을 확인 할 수 있습니다. The LEDs are off by RESET Button. By turning the dial, Pt-
-디스플레이 기능 : 기능 다이얼을 COUNT에 놓아두면 재폐로 총 누 Rt-Wt-T1-T2-T3. Preset value is shown on the display.
계 횟수를 지시합니다. - COUNT ERASE : The button is for erasing of cumulated
-COUNT ERASE Button을 누르면 디스플레이의 누계 횟수가 지워집 recolsed times.
- POWER LED(Green) : The LED is lighted during Aux. power
니다.
ON. If the LED is off caused by CPU Error, press RESET,
-POWER LED(Green) : Aux power가 정상이면 항시 켜져 있습니다. The POWER LED will be ON. If not, the relay have to be
만약 CPU 에러에 의한 꺼짐 상태라면, RESET를 누르면 복귀합니다. checked in detail by specialist.
만약 복귀되지 않을 경우 전문가에 의한 내부점검이 필요합니다. - SUCCESS LED(Green) : If reclosing is performed
-SUCCESS LED(Green) : 재폐로가 성공적으로 완료되면 커집니다. successfully, the LED is lighted. The LED is ON, until next
performing.
이 LED는 다음 재폐로 신호가 들어 올 때까지 켜져 있습니다.
- FAIL LED(Green) : The LED is lighted when auto reclosing
-FAIL LED(Red) : 재폐로를 실패하면 켜집니다. is failed.
-PREPARE LED(Yellow) : 재폐로를 수행 중에 켜집니다. - PREPARE LED(Yellow) : The LED is lighted under
-25-a LED(Green) : 동기 조건이 맞았을 시 켜집니다. performing reclosing funtion.
-Pt dip swith : 초기 준비 시간을 설정합니다. - 25-a LED(Green) : The LED is lighted when synchronizing
condition is OK.
-Rt dip swith : 리클레임 타임을 설정합니다.
- Pt : Preparing time set switch
-Wt dip swith : 웨이팅 타임을 설정합니다. - Rt : Reclaim time set switch
-T1/T2/T3 dip swith : 1,2,3차 재폐로 시간을 설정합니다. Dips with - Wt : Waiting time set switch
의 타임 정정값을 0(off)으로 놓으면 PASS기능을 합니다. 예를 들면 - T1/T2/T3 : reclosing time set switches. If set value is 0,
T3의 모든 swith 를 off로 놓으면 3회 재폐로는 수행되지 않습니다. then the Tx will be passed.
- NORMAL/LOCK : NORMAL means reclosing function in ON,
-NORMAL/LOCK Switch : NORMAL측으로 놓으면 재폐로 기능 적
while LOCK is off for the reclosing function.
용이며 LOCK측으로 놓으면 재폐로 기능을 off합니다. - RESET : After reclosing fail or one cycle of reclosing
-RESET : 재폐로 실패시 이 Button을 눌러 주어야 다음 사고시 재폐 function, the RESET will return all initial condition of the
로 기능을 수행합니다. reclosing relay for next performance.
-CPU RESET : CPU에러 발생시도 POWER LED가 DC전원 상실시 - CPU RESET : If CPU Error occurs, the POWER LED is off,
the LED is on by pressing the CPU RESET. If the LED is
와 같이 꺼집니다. 이때 이Button 을 누르면 복귀됩니다. 만일 전원
not ON, the relay have to be checked in detail by a
이 정상이면서 복귀되지 않는다면 릴레이의 자체를 점검해야 합니다. specialist.
- TEST : Pressing one time, Performing 1st reclosing function.
Pressing second(third) time with in reclaim time set,
※ 자체 재폐로 시험 방법
performing 2nd(3rd) time reclosing function. After three
재폐로 연동시험을 가상적으로 수행할시 과전류부(OC)는 순시로 설정하고 지락요소(EF)의 순시를
Lock 시킨후 한시로 동작할 수 있도록 설정한 후 재폐로 계전기와 연동시험을 하면됩니다. times performing. FAIL LED will be lighted by pressing one
1회 재폐로 OCR부의 순시로 동작 more time(4th). For initial condition, press RESET.
2회 재폐로GR부의 한시동작(시간 : 정한시-DEF- / 동작시간Lever : 최소
DRC-041 DRC-041
Connection
FEEDER PROTECTION & RECLOSING
NOTEl
① : 재폐로 신호(100mS) ② : Trip Signal
1. LPS - 모선 LINE 전압활선 및 Synchro Relay Contact-Nomal Close
2. 43RC - 재폐로 사용 및 잠금 Switch(Normal Close)
3. 79SX - 순시 Blocking용 Aux, Relay, 79FX-Lock Out용 Aux, Relay, 79PX - Preparing Completed, 28RX - OCR System Error,
79CX - Red System Error
4. 외부신호중 사용하지 않는 다음의 신호는 (+)에 연결한다.〔 20-a(Terminal- 1번 단자), 60CB-a(Terminal- 3번 단자)〕
디지털형 계전기
Digital Over Current and Earth Fault Relay [50/51X3, 50/51N]
Front View
Menu Specification
3. 조작부
� 이 디지털 계전기는 직접접지 또는 저항접지 개통인 배전선로
보호 및 수용가의 수전 변전소의 feeder 보호용에 적용할 수 있 � 셋팅 및 상태를 확인하기위한 조작시 사용되는 버튼
- MODE : MAIN SETUP을 진입하기위해 사용된다.
습니다. 이 릴레이는 다기능 / 광범위의 정정이 가능하므로 설계 - ENTER : SETTING된 값을 확정할 때 사용된다.
단계에서 정확하게 정정치를 계산하지 않아도 되므로, 릴레이 선 - ESC : 설정값을 취소하거나 상위메뉴로 빠져나오기위해 사용
택이 용이합니다. 된다.
- ▲, ▼, ◀, ▶버튼 : MENU를 스크롤하거나 선정값을 조정, 커서
의 위치변경에 사용된다.
4. CPU RESET
� CPU를 RESET할 때 사용한다. 단, 설정된값과 저장된 데이터는
지워지지 않는다.
5. CLEAR / VIEW
� LAMP의 RESET 및 LCD의 BACKLIGHT를 동작시킬때 사용된다.
- 1회 누름 : LCD의 BACKLIGHT 동작
- 2회 누름 : BACKLIGHT동작후 LAMP CLEAR
[ M A I N M E N U ]
4 . S E L F T E S T
5 . S E C U R I T Y S E T
1. TOC/IOC(OC)
1. SYSTEM SETUP [ T O C / I O C ] [ O C ]
- RELAY의 통신 및 CT비 등의 설정을 할 수 있다. T O C [ X . X ] L O C K ? [ N ]
I O C [ X ] L O C K ? [ N ]
2. OPERATING SETUP
- OC 및 OG관련 동작치 및 동작시간(커브)를 설정 할 수 있다.
▶ TOC : 과전류 설정항목이며 방향키(▲, ▼)를 이용하여 원하는
3. FAULT MEMORY 값을 설정한다.
- 최근 사고기록을 10개까지 확인할 수 있다. ▶ LOCK : 방항키(▲, ▼)를 이용하여 Y, N 값을 설정할 수 있다.
Y로 설정시 TOC는 동작 하지 않는다.
4. SELF TEST ▶ IOC: 순시전류 설정항목이며 방향키(▲, ▼)를 이용하여 원하는
- LAMP 및 RELAY 의 동작을 TEST할 수 있다. 값을 설정한다.
▶ LOCK : 방항키(▲, ▼)를 이용하여 Y, N 값을 설정할 수 있다.
5. SECURITY Y로 설정시 IOC는 동작 하지 않는다.
- PASSWORD 를 설정할 수 있다.
2. LEVER / CURVE(OC)
System Setup
[ L E V E R / C U R V E ] [ O C ]
� SYSTEM SETUP 상세 메뉴 L E V E R [ X . X ]
C U R V E [ N I ]
F R E Q U E N C Y [ X X ] H z
D E V I C E I D [ X X ]
C O M M S P E E D [ 1 9 2 0 0 ]
▶ LEVER : OC에서 설정된 이상의 값이 입력시에 동작시간을 설
C / T R A T I O [ X X X X ] / 5 A
정하는 항목이며 방향키(▲, ▼, ◀, ▶)를 이용하여 원
하는 값을 설정한다.
▶ CURVE : 방향키(▲, ▼)를 이용하여 DT, NI, VI, EI 값을 설정할
1. FREQUENCY 수 있다.
- 입력 전류의 주파수를 조정한다. - DT : Definite Time
▶ 방향키 (▲, ▼)를 이용하여 50 / 60Hz로 조정 할 수 있다. - NI : Normal Inverse
- VI : Very Inverse
2. DEVICE ID - EI : Extremely Inverse
▶ 방향키 (▲, ▼, ◀, ▶)를 이용하여 원하는 설정값을 입력한다.
3. TOC/IOC(OG)
3. COMM SPEED [ T O C / I O C ] [ O G ]
- RS 485 통신 사용시, 통신의 속도를 조정한다. T O C [ X . X ] L O C K ? [ N ]
▶ 방향키 (▲, ▼)를 이용하여 9600bps / 19200bps 설정이 I O C [ X ] L O C K ? [ N ]
가능하다.
[ L E V E R / C U R V E ] [ O C ] 1. TEST LAMP
L E V E R [ X . X ] ▶ 전면부의 L.E.D 불량여부를 검사하는 메뉴이다.
C U R V E [ N I ]
[ L E M P T E S T ]
[ E N T E R ] T O A L L L A M P
[ E S C ] T O Q U I T L E S T
▶ LEVER : TOC에서 설정된 이상의 값이 입력시에 동작시간을
설정하는 항목이며 방향키(▲, ▼, ◀, ▶)를 이용하여
원하는 값을 설정한다.
▶ CURVE : 방향키(▲, ▼)를 이용하여 DT, NI, VI, EI 값을 설정할 - 위의 메뉴상태에서 ENTER KEY를 누르면 전면부의 모든
수 있다. L.E.D가 점등하며, ESC KEY를 누르면 상위메뉴로 빠져나온다.
- DT : Definite Time
- NI : Normal Inverse 2. TEST RELAY
- VI : Very Inverse
- EI : Extremely Inverse [ R E L A Y T E S T ]
[ L E F T ] T O 0 C T R I P
[ R I G H T ] T O E F T R I P
FAULT MEMOY [ E S C ] t o Q U I T T E S T
�FAULT MEMORY 상세 메뉴
- 위의상태에서 LEFT KEY(◀)를 누르면 OC RELAY가 TRIP하
[ F A U L T M E M O R Y ] 며, RIGHT KEY(▶)를 누르면 EF RELAY가 TRIP한다.
1 . F A U L T R E C O R D ESC KEY를 누르면 상위메뉴로 빠져나온다.
2 . C L E A R F A U L T M E M
3. TEST SWITCH
1. FAULT RECORD [ S W I T C H T E S T ]
[ ] < - h e r e
[ F A U L T V I E W ] P r e s s & c h e c k s w i t c h
N 0 : 0 1 o f 1 0 r e c o r d s [ E S C ] t o Q U I T T E S T
P h a s e : X A m p : X X X . X
T y p e : x x x x C y c : x x x x x x - 위의 메뉴상태에서 각 Key를 누르면[ ]부분에 눌러진 Key의 값
이 표시된다. CPU RESET과 MODE KEY를 제외한 각 키의 불
▶ 사고전류 입력된후 TRIP이 되면 최고 10회까지 사고내용이 량여부를 확인 할 수 있다.
저장된다. ESC KEY를 누르면 상위메뉴로 빠져나온다.
▶ FAULT RECORD 선택시 나타나는 세부설정 항목
SECURITY SET
- NO : 기록값의 번호, 빠를수록 최근의 사고 기록이며 10개의
데이터 초과시 가장 나중값이 지워지며 다시 기록된다. � SECURITY SET 상세메뉴
- Phase : 사고발생 상을 표시한다. R, S, T상중 가장 먼저
TRIP이 발생한 사고상을 표시해준다. [ S E C U R I T Y P A S S W O R D ]
- Amp : 사고발생시 입력된 사고전류의 크기를 표시해준다. P A S S W O R D [ * * * * ]
- Type : 사고의 종류를 표시한다. 한시사고(Time)와 순시사고
(Inst)를 표시해준다. s e t ’ 0 0 0 0 ’ t o d i s a b l e
- Cyc : 사고전류 입력시(Pickup)에서 Relay Trip까지의
시간을 Cycle로 표시해준다. 1. SECURITY PASSWORD
▶ 제품의 PASSWORD를 설정하는 부분이다.
2. CLEAR FAULT MEM - 패스워드를 사용하지 않는 경우 :“000” 로 설정한다.
- 패스워드를 사용하는 경우 :“0001” ~”9999”사이의 숫자를
[ F A U L T C L E A R ] 입력한다.
C L E A R F A U L T R E C ? [ N ] [패스워드가 활성화 되고하면 MODE번튼을 누를 때 마다 패스
워드를 묻게 된다.]
- 패스워드를 잃어버렸을 경우 :“1183” 을 입력 한다.
[1183을 입력할 경우 패스워드가“0000”으로 초기화 된다.]
▶ 방향키(▲, ▼)를 이용하여 Y, N을 선택 할 수 있으며 Y선택시 저
장되어진 모든 사고 데이터가 삭제된다.
RATING
Rated Current AC 5A
Frequency 50/60Hz ± 5%
Burden OC 0.5VA, EF 0.2VA
Element (50/51) 3PHASE, 50N/51N
Standard Code IEC 255, KEMC 1120
Auxiliary Voltage AC/DC 80~260V
Memory Up to 10 records of Fault data
Communication RS-485 Mod-bus Protocol(9600/ 19200bps)
Ambient Temperature -10。~ 60。(with no icing)
CONTACT
AC 240V 10A 0.5sec (R/L=0ms)
Make
DC 1000W 0.5sec (R/L=0ms)
Capacity
AC 240V 3A 0.5sec (R/L=0ms)
Break
DC 30W 0.5sec (R/L=0ms)
INSULATION
Dielectric Withstacd 2KV for 1minute between all terminal
Insulation Resistance �100MΪ (DC 500V Megger)
Lightning Impulse Witihstand 5KV 1.2㎲ /50㎲ Positive/Negative 3Times
Surge Transient 2.5KV 1MHz/ 200Ϊ
CURRENT SETTING
Over Current : 0.2 ~ 15A (0.1A step)
OC
Type1 Insttantaneous : 5.0 ~ 80A (1A step)
Standard Over Current : 0.2 ~ 5A (0.1A step)
EF
Instantaneous : 1.0 ~ 40A (1A step)
OPERATING TIME
NI 300% : 6.30sec / 700% : 3.53sec
Over Current
VI 300% : 6.75sec / 700% : 2.25se
[LEVER 10]
EI 300% : 10.0sec / 700% : 1.67sec
NI 300% : 3.15sec / 700% : 1.76sec
Earth Fault
VI 300% : 3.37sec / 700% : 1.12sec
[LEVER 5]
EI 300% : 5.0sec / 700% : 0.83sec
TIME SETTING & CURVE (IEC 255-3)
OC / EF Lever 0.1 ~ 40 Lever (0.1 step)
Instantaneous Time Less than 50ms
0.14 tp
Normal inverse Time t = �
I 0.02 -1 10
13.5 tp I:%Current
Very inverse Time t = �
I - 1 10 (80% � 0.8)
80 tp (120% � 1.2)
Extremely Inverse Time t = 2 � tp : Time Lever
I - 1 10
Definite Time t = tp
■ Block diagram
■ Wiring
■ Terminal arrangement
(%)CURRENT (%)CURRENT
(%)CURRENT (%)CURRENT
Front View
Menu Specification
5. CLEAR / VIEW
� LAMP의 RESET 및 LCD의 BACKLIGHT를 동작시킬때 사용된
다.
- 1회 누름 : LCD의 BACKLIGHT 동작
- 2회 누름 : BACKLIGHT동작후 LAMP CLEAR
42 DEESYS TOTAL PRODUCTS GUIDE
Digital Over & Under Voltage Relay [59/27]3
Menu Specification
Main Menu OPERATING SETUP
� 전원 투입시 초기화면 � 전원 투입시 초기화면
[ O P E R A T I N G S E T U P ]
1 . O V E R V O L T A G E
3 P H A S E O V E R &
2 . L E V E R / C U R V E ( O V )
U N D E R V O L T A G E
3 . U N D E R V O L T A G E
v . X X
4 . L E V E R / C U R V E ( U V )
� MODE 버튼을 누른후 나타나는 MENU 화면
[ M A I N M E N U ]
1 . S Y S T E M S E T U P
2 . O P E R A T I N G S E T U P
3 . F A U L T M E M O R Y
1. OVER VOLTAGE
[ O V E R V O L T A G E ]
[ M A I N M E N U ] O V [ X . X ] L O C K ? [ N ]
4 . S E L F T E S T
4. SELF TEST
- LAMP 및 RELAY 의 동작을 TEST할 수 있다.
▶ LEVER : OV에서 설정된 이상의 값이 입력시에 동작시간을 설
정하는 항목이며 방향키(▲, ▼, ◀, ▶)를 이용하여 원
하는 값을 설정한다.
▶ CURVE : 방향키(▲, ▼)를 이용하여 DT, NI 값을 설정할 수 있
다.
System Setup - DT : Definite Time
� SYSTEM SETUP 상세 메뉴 - NI : Normal Inverse
F R E Q U E N C Y [ X X ] H z 3. UNDER VOLTAGE
D E V I C E I D [ X X ]
C O M M S P E E D [ 1 9 2 0 0 ] [ T U V / I U V ] [ U V ]
T U V [ X . X ] L O C K ? [ N ]
I U V [ X . X ] L O C K ? [ N ]
1. FREQUENCY
- 입력 전압 및 전류의 주파수를 조정한다.
▶ 방향키 (▲, ▼)를 이용하여 50 / 60Hz로 조정 할 수 있다.
▶ TUV : 부족전압 설정항목이며 방향키(▲, ▼)를 이용하여 원하
는 값을 설정한다.
2. DEVICE
▶ 방향키 (▲, ▼, ◀, ▶)를 이용하여 원하는 설정값을 입력한다.
▶ LOCK : 방향키 (▲, ▼)를 이용하여 Y, N값을 설정할 수 있다.
Y로 설정시 TUV는 동작 하지 않는다.
3. COMM SPEED
- RS 485 통신 사용시, 통신의 속도를 조정한다.
▶ 방향키 (▲, ▼)를 이용하여 9600bps / 19200bps 설정이
가능하다.
[ L A M P T E S T ]
▶ LEVER : TUV에서 설정된 이상의 값이 입력시에 동작시간을
[ E N T E R } T O A L L L A M P
설정하는 항목이며 방향키(▲, ▼, ◀, ▶)를 이용하여
[ E S C ] T O Q U I T T E S T
원하는 값을 설정한다.
▶ CURVE : 방향키(▲, ▼)를 이용하여 DT, NI 값을 설정할 수 있
다.
- DT : Definite Time - 위의 메뉴상태에서 ENTER KEY를 누르면 전면부의 모든
- NI : Normal Inverse L.E.D가 점등하며, ESC KEY를 누르면 상위메뉴로 빠져나온다.
2. TEST RELATY
FAULT MEMOY
[ R E L A Y T E S T ]
� FAULT MEMORY 상세 메뉴 [ L E F T ] T O 0 V T R I P
[ R I G H T ] T O U V T R I P
[ F A U L T M E M O R Y ] [ E S C ] t o Q U I T T E S T
1 . F A U L T R E C O R D
2 . C L E A R F A U L T M E M
- 위의상태에서 LEFT KEY(◀)를 누르면 OV RELAY가 TRIP하
며, RIGHT KEY(▶)를 누르면 UV RELAY가 TRIP한다.
ESC KEY를 누르면 상위메뉴로 빠져나온다.
1. FAULT RECORD
▶ 사고전압이 입력된후 TRIP이 되면 최고 10회까지 사고내용이
3. TEST SWITCH
저장된다.
▶ FAULT RECORD 선택시 나타나는 세부설정 항목 [ S W I T C H T E S T ]
[ ] < - h e r e
[ F A U L T V I E W ] P r e s s & c h e c k s w i t c h
N 0 : 0 1 o f 1 0 r e c o r d s [ E S C ] t o Q U I T T E S T
P h a s e : X V O L T : X X X . X
T y p e : x x x x C y c : x x x x x x
- 위의 메뉴상태에서 각 Key를 누르면[ ]부분에 눌러진 Key의 값
이 표시된다. CPU RESET과 MODE KEY를 제외한 각 키의 불
- NO : 기록값의 번호, 빠를수록 최근의 사고 기록이며 10개의
량 여부를 확인 할 수 있다.
데이터 초과시 가장 나중값이 지워지며 다시 기록된다.
ESC KEY를 누르면 상위메뉴로 빠져나온다.
- Phase : 사고발생 상을 표시한다. R, S, T상중 가장 먼저
TRIP이 발생한 사고상을 표시해준다.
- Volt : 사고발생시 입력된 사고 전압의 크기를 표시해준다. SECURITY SET
- Type : 사고의 종류를 표시한다. 과전압/ 부족전압을 표시해
� SECURITY SET 상세메뉴
준다.
- Cyc : 사고전압 입력시(Pickup)부터 Relay Trip까지의 시간 [ S E C U R I T Y P A S S W O R D ]
을 Cycle로 표시해준다. P A S S W O R D [ * * * * ]
[ F A U L T C L E A R ]
C L E A R F A U L T R E C ? [ N ] 1. SECURITY PASSWORD
▶ 제품의 PASSWORD를 설정하는 부분이다.
- 패스워드를 사용하지 않는 경우 :“0000” 로 설정한다.
- 패스워드를 사용하는 경우 :“0001” ~”9999”사이의 숫자를
입력한다.
▶ 방향키(▲, ▼)를 이용하여 Y, N을 선택 할 수 있으며 Y선택시 저
[패스워드가 활성화 되고나면 MODE번튼을 누를 때 마다 패스
장되어진 모든 사고 데이터가 삭제된다.
워드를 묻게 된다.]
- 패스워드를 잃어버렸을 경우 :“1183” 을 입력 한다.
[1183을 입력할 경우 패스워드가“0000”으로 초기화 된다.]
RATING
Frequency 50/60Hz ± 5%
CONTACT
INSULATION
Dielectric Withstand 2KV for 1minute between all terminal & case earth
VOLTAGE SETTING
OPERATING TIME
■ Block diagram
■ Wiring
■ Terminal arrangement
12.15 tp
t= ( +0.35) ×
V 2-1 10
P1
Cap. Rated
(KVA) (A) 0.01s 0.05s 0.1s 0.5s 1s 5s several ten times of rated currents, it would, at the peak of
20 1.7 28.3 16.8 12.8 5.7 4.2 1.9 flowing time 1~2Hz, take 2 seconds to 3 seconds for getting
30 2.6 43.3 25.7 19.6 8.8 6.4 2.9 returned to rated currents. This is what we call "excitation in-
50 4.4 64.8 4.05 21.4 14.2 10.1 4.7 rush currents and currents protective coordination between
75 6.6 76.0 47.5 36.8 16.6 11.9 6.6
oil filled transformer
DOG-M51D
특징 Feature
이 다기능 과전류 계전기는 마이크로 프로세서 기술을 적용한 계전기 The multi-OCR is a microprocessor based digital type
로서 3상 과전류 요소와 접지 과전류 요소를 가진 계전기입니다. protective relay that has 3 phases overcurrent and ground
OCR과 OCGR는 독립적으로 정정 가능합니다. 보호협조는 (1)반한시, overcurrent element which are provided with inverse, very
강반한시, 초강반한시, 중 1개 요소와 순시 요소 또는 (2)정한시 적용 inverse, extremely inverse, and definite time, curkes. OCR
할 수 있습니다. 본 릴레이는 마이크로 프로세서 칩 및 A/D 컨버터등 and GOCR can set the functions independently. The relay
최첨단 기술의 적용으로 기존의 기계식이나 정지형 보다 월등히 정밀 may be supplied in drawout type case or fixed type case
하고 정확히 동작합니다. according to customer's requirement. Its protceting
coordination is configured with (1) one of time inverse
curvesand instananuouse setting, or (2) definite time setting.
The relay works more precisely and correctly than
electmechanical type or static type, because of appling
advanced digital converting technology.
적용 Application
이 다기능 계전기는 직접접지 또는 저항접지 계통인 배전선로 보호 및 The relay is suitable for solid or resistance grounded
수용가의 수전 변전소의 feeder 보호용에 적용 할 수 있습니다. 계전 distribution feeder of utility company or cosumer's substation.
기는 다기능/광범위 정정이 가능하므로, 설계단계에서 정확하게 정정 Since the relay has multi-funtions and wide range settings. it
치를 계산하지 않아도 되므로, 계전기 선택이 용이합니다. is no necessary for engineer to calculate in detail at the
beginning of design.
Front plate
Specifications
Indication
Earth N ●
Fault Instantaneous ● ●
Is=2+1.0+2.0=5(A)
※ Lock위치로 ON-setting하면 ON기능이
동작하지 않습니다.
Ts=0.25+0.25+0.5+1.0+1.5+2.5+4.0
=10 lever
Is=2+1.0+2.0=5(A)
※ Lock위치로 ON-setting하면 ON기능이 If the dip switch is set on lock position, the instantaneous
동작하지 않습니다. function is not operated.
Block diagram
Block diagram
Terminal arrangment
Terminal arrangement
DOC-M32D , DOC-M42D
특징 Characteristics
기능 Function
C.P.U를 내장하여 고신뢰도 및 정확도를 만족시키기 위해 MICOM화 Computerized by having C. P. U built-in the function to
하였습니다. Digital방식에 의한 고정밀화로 기능에 안정성을 실현하였 high reliability and accuracy and stabilized sopisticated
습니다. 자기감시기능을 채택하여 고장유무상태를 보다 신뢰성있게 향 function through digital system.
상 시켰습니다. Multi function으로 표시 및 다기능에 충실하였습니다. Easy detection of malfunction with self-checking set.
Convenient operation, based on multifunction. As target
표시선택 was installed, overload and short circuit can be clearly
상시부하전류가 계측이 되어 Metering의 표시가 가능합니다. 정정치의 detected phase by phase.
식별이 가능하여 setting후 정확한 위치가 표시됩니다. 유도 원판형의
Display
회전표시에 대응하는 동작상태의 time counter가 표시되어 동작상태의 Convenient meter scale indicates the load state of currents
확인이 가능합니다. passing all the time. Setting value of operating current is clearly
구조 discernable and correct position, also detectable after setting.
EMC에 대응하여 case구조 및 내부회로를 특수설계하여 고신뢰성을 With time counter setting it can surely confirm operating
확보하였습니다. condition. Based on test SW, easy check-up can be
인출, 비인출형 구조로 되어있어 시공 및 현장 시험시 편리합니다. performed.
계전기 인출시 CT회로 개방에 대한 대책이(Short bar)되어있어 CT의 Construction
소손을 방지할 수 있습니다. Case construction corresponding to EMC and inner circuit
was specifically designed for ensuring high reliability.
Drawout and non-draw out type was so well constructed
that setting and field test can be conveniently performed.
Front plate When drawing out, short bar keeps CT circuits from burning
down.
Specifications
●MODEL Indicator
DOC-M32(Non Draw out) 2 phase Operating start LED(Red)
DOC-M32D(Draw out) 2 phase CPU RUN LED(Gre)
DOC-M42(Non Draw out) 3 phase Operating LED(Red)
DOC-M42D(Draw out) 3 phase ●Operating time
●Rating Over Current Lever #10
Rated current AC 5A Normal inverse time 300% 6.3 sec
Frequency 60/50㎐±5% 700% 3.5 sec
Auxiliary Voltage AC/DC 110V(86~260V) Very inverse time 300% 6.75 sec
Ambient temperature -10℃ to 60℃(with no 700% 2.25 sec
icing) Extremely inverse time 300% 10 sec
●Current setting 700% 1.67 sec
Overcurrent range 2~10A Lock(Steps of Instantaneous time 300%
0.5A) Degree Protection IP52
Instantaneous range 20~80A Lock(Steps of Thermal Withstand Capability for 1s 80xIn Continuously
5A) 3xIn
3.5 120
6 137 4 137 3 137
1,000
4.5 154
3.5 160
5 171
4 122
3 137
1,500 6 137 4.5 137
5 153 3.5 160
Wiring
Terminal Arrangement
Non draw out Draw out Non draw out Draw out
Dimension
Case : ABS 난연성(Non flamable)
Digital type draw out Color : Black(N1.5) Cutting Size: 165 X 122mm
DCG-M22D
특징 Feature
이 접지 과전류 계전기는 마이크로 프로세서 기술을 적용한 접지 요소 The OCGR is a microprocessor based digital type protective
를 가진 계전기 입니다. 보호협조를 위하여 relay that has ground overcurrent detecting elements. For
1. 반한시, 강반한시, 초반한시 곡선중 1요소와 순시요소를 조합하여 protecting coordination, it could be applied with:
정정하거나 1. Instant. GOC with one of normal inverse, very inverse, and
2. 정한시 요소를 단독으로 적용 할 수 있도록 선택 할 수 있습니다. extremely inverse curves or
이 계전기는 A/D컨버터 및 CPU를 내장하고 있기 때문에 일반 정 2. Alone with definite time
지형이나 기계식에 비하여 월등히 정확하고 신속하게 동작합니다. Since a fault level is treated by A/D converter and
calculated by CPU, the fault detected, is more correct and
precise than E/M type or static type.
적용 Application
이 접지 과전류 계전기는 직접접지 또는 저항접지계통에 적용 할 수 The OCGR is applied to solid ground or resistance ground
있으며, 정정범위가 넓어 설계단계에서도 리레이 선택이 용이 합니다. network. More-over the relay could be chosen at the
begining of design stage, since its adjustable range is
wider than other relays.
Front plate
Specification
◆MODEL ◆Operating time
DCG-M22(Non Draw out) Over Current Lever #10
DCG-M22D(Draw out) Normal inverse time 300% 6.3 sec
◆Rating 700% 3.5 sec
Rated current AC 5A Very inverse time 300% 6.75 sec
Frequency 60/50㎐±5% 700% 2.25 sec
Auxiliary Voltage AC/DC 110V(86~260V) Extremely inverse time 300% 10 sec
Ambient temperature -10℃ to 60℃(with no icing) 700% 1.67 sec
Instantaneous time Iess then 0.04 sec(200%
◆Current setting
overcurrent)
Overcurrent range 0.2~2A Lock(Steps of 0.05A)
Degree Protection IP52
Instantaneous range 1~40A(Steps of 0.5A)
Thermal Withstand Capability for 1s 80xIn Continuously
◆Time setting & curve IEC 255 3xIn
Overcurrent time lever 0.25~40(Steps of 0.25)
◆Vibration resistance
Instantaneous Less than 40ms(over
Malfunction 10㎐ 5mm double
200%)
amplitude 30s each in X
0.14 tp and Y directions
∙Normal inverse time NI= 0.02-1 �10
16.7㎐ 2.5mm double
13.5 tp amplitude 600s each in
∙Very inverse time VI= �
-1 10 X,Y, and Z directions
80 tp
∙Extremely inverse time EI= 2-1 � ◆Shock resistance
10
Destruction; 300㎨(approx. 30G) 3
tp
∙Definite time DE= 2 � time each in 3
10
directions
Resetting Value > 95% ◆Insulation to IEC 255
Reset time < 100ms Dielectric withstand 2㎸ for 1 minute
◆Burden between all terminals
Overcurrent 0.5VA and case earth
Aux Voltage 12VA(AC),6W(DC) Insulation resistance at 500V >100㏁
Impluse Voltage Withstand 5kV-1.2/50 ㎲
◆Contact
Surge transient simulator 2.5kV 1MHz/200Ϊ
Output Relay Trip 1c, Alarm 1a
Weight 2.0kg
Trip & Alam contact capacity
Make AC 240V 10A(L/R=0ms)
DC 1000W 0.5Sec(L/R=0ms)
Break AC 240V 3A(L/R=0ms)
DC 30W 0.5Sec(L/R=0ms)
Indicator
Operating start LED(Red)
Operating LED(Gre)
Wiring
Terminal arrangement
DOU-M22D
[ 1∅ ] [ 3∅ ]
특징 Characteristics
● 종래의 과전압, 부족전압을 별도의 계전기로 사용하던 것을 과, 부 ● Up to now OVR and UVR relays were separately set and
족 전압을 1대의 계전기에 내장하였습니다. also operated but they are compacted in one relay unit.
● 고정밀 기능과 다기능의 조합으로 보호협조 및 수배전단의 적용에 So very convenient for handling too.
최적입니다. ● As assembled with state of art and multifunctions, it is most
● 계전기 전면에 정밀 Volt meter가 설치되어 있어 계측용으로 가능 suitable and applicable to protective coordination.
합니다. ● Volt meter being installed, it can be used fer measuring
● 전자식 동작표시기 및 LED가 부착되어 있어 정전 및 사고상태의 ● Electronic indicator target accurately show the troubles
판별이 명확히 표시됩니다. and surely indicate electric trouble.
Front plate
Specifications
◆MODEL ◆Operating time
DOU-M22(Non Draw out) Over Voltage Inverse or definite time
DOU-M22D(Draw out) Under Voltage Inverse or definite time
Degree Protection IP 52
◆Rating
Rated Voltage AC 110V ◆Vibration resistance
Frequency 60/50㎐±5% Malfunction 10㎐ 5mm double
Auxiliary Voltage AC/DC 110V(80~260V) amplitude 30s each in X
Ambient temperature -10℃ to 60℃(with no icing) and Y directions
16.7㎐ 2.5mm double
◆Voltage setting amplitude 600s each in
Over Voltage range 115~150V/(Steps of 5V) X,Y, and Z directions
Under Voltage range 20~100V/(Steps of 5V)
◆Shock resistance
◆Time setting & Curve Definite time or Inverse time Destruction; 300㎨ (approx. 30G)
Over Voltage time lever 0.05~10.3(steps of 0.05) 3 time each in 3
0.05±25ms, 0.1~10S±10% directions
Under Voltage time lever 0.05~10.3(steps of 0.05)
0.05±25ms, 0.1~10S±10% ◆Insulation to IEC 255
Under Voltage Instantaneous 20~80V(Steps of 5V) Dielectric withstand 2kV for 1 minute
Resetting Value OV:V<95%, UV:V> 105% between all terminals
Reset time < 100ms and case earth
Insulation resistance at 500V >100㏁
◆Burden Impluse Voltage Withstand 5kV-1.2/50 ㎲
Over Voltage Less than 2VA Surge transient simulator 2.5kV 1MHz/200Ϊ
Under Voltage Less than 2VA Weight 2.0kg
Aux. Voltage 12VA(AC), 6W(DC)
◆Contact
Out put Relay OV : 1C / UV : 1C
Trip & contact capacity
Make AC 240V 10A(L/R=0ms)
DC 1000W
0.5Sec(L/R=0ms)
Break AC 240V 3A(L/R=0ms)
DC 30W
0.5Sec(L/R=0ms)
◆Indicator
Operating start LED(Red)
Operating LED(Red)
Specifications
◆Rating ◆Indicator
Rated Voltage AC 110V Operating start LED(Red)
Frequency 60/50㎐±5% Operating(Trip) LED(manual Reset)
Auxiliary Voltage AC/DC 110V(80~260V)
Ambient temperature -10℃ to 60℃(with noicing) ◆Operating time
Over Voltage
◆Voltage setting Under Voltage Inverse or definite time
Over Voltage range 100~160V/(steps of 5V) Degree Protection IP 52
Under Voltage range 50~120V/(steps of 5V)
◆Vibration resistance
◆Time setting & Curve Malfunction 10㎐ 5mm double
Over Voltage time INST. 0.1~10(steps of 0.1)±10% amplitude 30s each in X
Under Voltage time INST. 0.1~10(steps of 0.1)±10% and Y directions
Instantaneous time Less than 60ms 16.7㎐ 2.5mm double
Reset Value OV:V<95%, UV:V> 105% amplitude 600s each in
Reset time Less than 100ms X,Y, and Z directions
Block diagram
Wiring
V-Connection 110V
Y-Connection 110V
Terminal Arrangement
Demension
Case : ABS 난연성(Non flamable)
Digital type draw out Color : Black(N1.5) Cutting Size: 165 X 122mm
DOV-M15D, DUV-M20D
개요 Introduction
이상 전압에는 발전기의 고장으로 인해 전압의 급상승과 정전시 또는 In abnormal voltage condition, voltage shall be dropped
단락시에 전압이 저하됩니다. 전압계전기는 교류회로의 전압변동에 대 because of sudden increasing voltage due to generator's
응하여 전압을 미리 정정하여 놓고 정정치 이상이 되면 검출하여 동작 fault and power off or short circuit time.
하는 계전기 입니다. Normally, voltage relay setting shall be done priorly against
the voltage variation.
When voltage become over the setting value, voltage relay
shall be operated.
특징 Characteristics
● 고정밀 반도체로 내부회로를 구성하여 반영구적으로 사용이 가능 ● Control voltage is obtained from power transformer
하며 진동이나 충격에 오동작할 염려가 없습니다. secondary without requiring any separate source of power
● A/D Converter 회로를 구성하여 입력전압을 FND로 Display supply that system configuration wiring and handling are
함으로 Volt Meter 대용으로 사용 가능합니다. convenient.
● 사고를 정확하게 표시하는 Target을 부착하였습니다. ● Internal circuit constructed of semiconductors offer
● 소비 전력이 적어서 PT의 부담이 적어도 되므로 경제적입니다. semipermanent sevice life without worries for
malfunctioning caused by mechanical vibration and
shocks.
Front plate ● A/D converter circuit offers digital display of input
voltages(substitutes AC voltmeter)
● Target shall show the fault condition accurately.
● Due to low power consumption and low burden of PT, this
relay is economical.
Specifications
● Model ● Indicator
DOV-M15(Non Draw out) Operating start LED(Red)
DOV-M15D(Draw out) Operating(trip) Target(Manual Reset)
DUV-M20(Non Draw out)
DUV-M20D(Draw out) ● Operating time
Over Voltage Inverse or definite time
● Rating Under Voltage
Rated Voltage AC 110V Degree Protection IP 52
Frequency 60/50㎐±5%
Auxiliary Voltage AC/DC 110V(80~260V) ● Vibration resistance
Ambient temperature -10℃ to 60℃(with no icing) Malfunction 10Hz 5mm double
amplitude 30s each in X
● Voltage setting and Y directions
Over Voltage range 115~150V/(steps of 5V) 16.7Hz 2.5mm double
Under Voltage range 20~100V/(steps of 5V) amplitude 600s each in
Under voltage 20~80V/(steps of 5V) X,Y, and Z directions
instantaneous range
Shock resistance
● Time setting & Curve Definite time or Inverse time Destruction; 300㎨(approx. 30G) 3
Over Voltage time 0.05~10.3(steps of 0.05) time each in 3
Under Voltage time 0.05~10.3(steps of 0.05) directions
0.05±25ms, 0.1~10S±10%
Instantaneous time Less than 60ms Insulation to IEC 255
Reset value OV:V<95%, UV:V> 105% Dielectric withstand 2kV for 1 minute
Reset time Less than 100ms between all terminals
and case earth
● Burden Insulation resistance at 500V >100㏁
Over Voltage Less than 2VA Impluse Voltage Withstand 5kV-1.2/50 ㎲
Under Voltage Less than 2VA Surge transient simulator 2.5kV 1MHz/200Ϊ
Aux. Voltage 12VA(AC), 6W(DC) Weight 2.0kg
● Contact
Out put Relay Trip 1c, Alarm 1a
Trip & contact capacity
Make AC 240V 10A(L/R=0ms)
DC 1000W 0.5Sec(L/R=0ms)
Break AC 240V 3A(L/R=0ms)
DC 30W 0.5Sec(L/R=0ms)
Block diagram
Wiring
Non draw out Draw out
Terminal Arrangement
Non draw out Draw out
Dimension
Case : ABS 난연성(Non flamable)
Digital type draw out Color : Black(N1.5) Cutting Size: 165 X 122mm
DVG-M11D
특징 Characteristics
● 본 계전기는 수배전단의 비접지방식의 전력계통에 사용되는 지락과 ● The relay is used in non-grounded power system of
전압계전기로 GPT를 이용하여 지락사고시 CB를 TRIP시키는데 사 distribution lines of power station for the purpose of
용되는 계전기입니다. tripping circuit breaker through the use of GPT.
● 지락시 GPT의 3차측에서(a,f간) 유기된 지락전압을 이용하여 동작 ● As it is operated by detecting ground fault from third end
하는 계전기로 cable의 정전용량에 대해 오동작 우려가 없습니다. of GPT, no concen for malfunction caused by static
● 소비전력이 적어 PT의 부담이 작아도 되므로 경제적입니다. capacity of cable to ground.
● 동작특성에 대한 구성은 정밀급 반도체로 구성되어 있어 오차범위 ● It is enconomical to use as modest power dissipation
가 적습니다. formal PT. Accordingly smaller current limiting resistor(W)
● 계전기가 동작되면 전자 동작표시가(Target)가 있어 사고후의 상태 will be required.
를 알수 있습니다. ● Since the operation is highly sensitive, it is adequate for
use in detection grounding fault of generators.
● Target shall show the fault condition accurately.
Front plate
Specifications
● Indicator
Operating start LED(Red)
Operating(trip) Target(Manual Reset)
Dimension
Block diagram
Terminal arrangement
DDG-M22D
특징 Characteristics
비접지계의 지락보호 방식으로 사용되는 지락방향계전기는 배전계통의 Directional ground relay being non-grounded type ground
1선지락시에 발생하는 영상전압과 영상전류로 동작하는 계전기입니다. protection is activated by zero phase sequence
voltage(tertiary voltage of GPT installed on bus line) and zero
● 왜파에 대해서도 정확히 동작할 수 있도록 입력부에 정밀도 Filter phase sequence current (secondary current of ZCT installed
회로를 내장하였습니다. on each phase)
● 영상전압(Vo) 입력부의 부담을 적게 하였으므로 부담이 적은 접지
용변압기 (G.P.T)한대로도 많은 계전기를 동시에 수용할 수 있습니 ● A precision fillter circuit is employed at input end for
다. accurate determination of the detection even when signal
wave form is distorted.
● 고속 및 시간 정정탭이 설치되어 후비보호협조가 가능합니다. ● Since the burden of zero phase sequence voltage (Vo)
input end is minimized, any single unit of small capacity
ground potential transformer (GPT) can support several or
more relays at one time.
● Taps provided for time limit setting offer convenient means
of reserver protection.
Front plate
1. Display
2. Io Element(G.V.T)
3. Time Elemnent
4. Vo Elemnent
5. Angle Elemnent
6. Vo Value Indicator
7. Io Value Indicator
8. CPU RUN Indicator
9. Power Indicator
10. Monitor Select S/W
11. Setting Check S/W
12. Test S/W
13. Frequency Select
14. Pick-up Indicator
15. Trip Indicator
16. Reset S/W
Specifications
● Model ● Contact
DDG-M22(Non Draw out) Out put Relay Trip 1c, Alarm 1a
DDG-M22D(Draw out) Trip & Alarm contact capacity
● Rating Make AC 240V 10A(L/R=0ms)
GPT input AC 110/190 DC 1000W 0.5Sec(L/R=0ms)
ZCT 200㎃/100㎷ Break AC 240V 3A(L/R=0ms)
Frequency 50/60Hz±5% DC 30W 0.5Sec(L/R=0ms)
Auxiliary Voltage AC/DC 110V(86~260V) ● Indicator
Ambient temperature -10℃ to 60℃(with no icing) Operating(trip) LED
● Current setting ● Vibration resistance
Operating Malfunction 10㎐ 5mm double amplitude 30s
Current Setting tap(lo) 0.1-1.0A(0.1A step)±10% each in X and Y directions
Voltage Setting tap(Vo) 5~82.5V(steps of 2.5V) 16.7㎐ 2.5mm double amplitude
Characteristic angle 0~180。 (steps of 5。 ) 600s each in X,Y, and Z
Zone of operating ±90(Error±10。 )(lead) directions
● Time setting Curve ● Shock resistance
Operating Destruction; 300㎨(approx. 30G) 3 time each
Time tap 0.05~10s (steps of 0.05 sec) in 3 directions
Resetting Value >95% ● Insulation to IEC 255
Reset time <100ms Dielectric withstand 2kV for 1 minute between all
● Burden terminals and case earth
G. P. T terminal(G1, G2) Less than 1VA Insulation resistance at 500V >100㏁
Aux. Voltage 8VA(AC) Impluse Voltage Withstand 5kV-1.2/50 ㎲
Surge transient simulator 2.5kV 1MHz/200Ϊ
Weight 2.2kg
Wiring
Non draw out Draw out
Terminal arrangement
Non draw out Draw out
HZR . HZS TYPE Sophisticated ZCT for supporting Ground fault relay
● 사용시 안정성을 추구하였고, 종래의 ZCT보다 저가품으로 설계되
었습니다.
● 사용전류 범위가 광폭형으로 설계되어 Cable 작업시 편리한 구조
로 되어 있습니다.
● 경구조물로 되어 있어 판넬 취부에 용이하고, Cable 선정에 따라
다른 종의 영상변류기가 구비되어 있습니다.
Specifications
Dimension
Item A B C D E F G H Hole(∅)
HZR-050 50 25 131 100 122 7 32 36 6
HZR-065 65 26 143 114 133 7 39 37 6
HZR-080 80 34 174 160 180 7 40 40 6
HZR-100 100 38 203 160 180 7 40 40 6
HZR-120 120 45 225 180 210 16 55 35 10
HZR-150 150 45 260 180 210 16 55 35 10
HZR-200 200 53 310 260 286 10 70 35 10
Specila Specification
Epoxy 65∅,120∅
HGR,DGR
Mold 150∅,200∅
특징 Characteristics
● 전력계통의 전압결상 및 반상 기능으로 후비보호에 최적이며 전압 ●The relay is best suitable for back up protection reserve
검출을 이용하여 구동시키므로 결선이 간편하고 고압 및 저압에 사 against loss and damage caused by open phase in power
용되는 계전기 (PT 2차 사용) system and applicable to both high and low voltage without
● 결상이 되면 동작표시기(LED)가 설치되어 있어 사고의 판별이 명확 requiring power source. It offers wiring convenience since it
히 구분됩니다. is driven by detecting voltage
● 계전기는 3상 입력 전압이 있어야 정상동작 합니다. ●When a phase open is detected, indicator lamp(LED) is
turned on for the phase line so that the fault line is
identified visibly.
●It will not operate when 3 phase line power is not available.
Specifications
● Burden
Rated burden 1VA
● Contact
Out put Relay Trip-1c Alarm-1c
Trip & Alarm contact capacity
Make AC 240V 10A(L/R=0ms)
DC 1000W 0.5Sec(L/R=0ms)
Break AC 240V 3A(L/R=0ms)
DC 30W 0.5Sec(L/R=0ms)
● Indicator
Operating RVS LED(YEL)
Trip LED(RED)
Resetting Manual Reset(Indicator)
Block diagram
Wiring
Terminal arrangement
DHG-021ND
특징 Characteristics
비접지식에 사용되는 고압 지락계전기는 공장 또는 고압설비 및 기기 H. V ground relay is applied for protection of factories. HV
의 지락 사고를 신속히 검출하는 무방향성 지락계전기로서 영상 변류 heavy-duty facilities or the relative apparatus, detecting
기와 조합하여 사용되는 계전기입니다. instantly earth-fault. This non-directional relay is inconbination
● 고조파 및 Surge의 영향을 받지 않는다. with ZCT
● 자체 스위치 시스템에 있어 계전기의 정상상태 확인이 가능합니다. ● Free from high frequency or surge.
● 동작표시가 부착되어 있어 사고후 판별이 가능합니다. ● With self checking switch set, normal operation can be
● 인출형이 가능하여 점검 및 보수가 편리합니다. easily confirmed at any operation at any time, if need.
● Indicator can detect any wrong-operation after earth fault.
● Easy check-up and maintainance.
Specifications
지락사고 검출방법에는 사용하는 계전기에 따라 The designation of relay varies as follows according to
① 지락전류 검출방식 detecting method.
영상변류기 + 지락과전류 계전기 + 지락계전장치 ① GR Detection:
② 영상전압검출방식 : 지락과전압계전기 ZCT + OCGR + GR apparatus
③ 위상검출방식: 지락방향계전기의 방법이 있으나 변압기 2차측은 평 ② GPT Detection : OVGR Relay
상 배전길이가 짧고 Feeder수가작은 것에는 ①,② ③ Phase Detection ; DGR Relay
의 방법으로 검출하면 된다. 특히 전압측의 비접지 Where distribution line is very short and the number of
방식에서는 접지보상용 콘덴서의 적용이 필수적이다. feeder is small too. (1),(2) methods are applicable and
2lt suitable. Especially, in non grounding mode is required to
∴ 콘덴서계산식 C = (F)
2πf √
3V apply the condenser of zero-phase detction unit
lt : 계전기 정정치 2lt
∴ Condenser C = (F)
2πf √
3V(A)
fc √3V(A)
∴ 완전지락시 계산식은 lg = 2π
lt : Relay setting value
fc √3V(A)
∴ Ground Fault lg = 2π
수용가 구내에 대지간 정전용량이 적으면 고압기기 등의 보호(미소자 Conisidering that once electrostatic capacity in between
락 전류에서 동작시키면 피해가 적다.) 를 생각하여 최소탭으로 놓는 service area in consumer end is small, and high voltage
것이 좋다. 그러나 구내에 고압케이블 배선이 많고. 100m 를 넘을 경 device shall be protected small, and high voltage device shall
우에는 현행 KS의 제품은 비방향성이므로 200mA탭 이하에서는 수용 be protected(operation in tiny earth fault causes little
가 구내가 아니고, 구외의 (ZCT부터 전원측) 배선의 지락사고를 불필 damage)keeping tiny tap in minimum will be suitable. But
요하게 동작되는 경우가 있다. 배전선의 미소지락 사고등으로 가끔 관 when there are high voltage wiring in service area, ground
계없는 수용가측에서 정전이 되는 불편을 주고, 이와 같은 경우에는 fault can frequently occur. Accordingly, consumer end is
탭을 1~2단계 높여서 400mA~600mA로 하면 불필요동작을 하지 troubled with power cut-off, due to tiny fault of power
않게 된다. 고압기기와의 보호관계상수용가 지락계전장치의 탭을 distribution. In such case, tap shall be raised 1~2 steps to as
200mA로 놓을 경우 혹은 600mA, 800mA등 최고 탭에 대해서도 협 much as 400mA~600mA. Poor coordination continues
조가 안되는 경우에는 비접지식의 것으로, 방향성을 갖는 것을 사용하 caused by max tap, in non-grounding directional relay DDG-
면 불필요한 동작이 없고 충분히 만족을 시킬 수 있다. 이런 경우에는 M22 will get into normal role.
방향성계전기인 DDG-M22형을 사용하면 된다.
norminal area for 0.2A setting for 0.4A setting Voltage Item norminal JISC3606(CV)
(㎟) (m) (m) (㎟) ㎌/㎞
8 135 270 8 0.63
14 115 230 14 0.78
22 0.90
22 100 200 38 1.11
38 85 170 3.3KV 3Core 60 1.14
(3 ∅3W) 100 1.41
60 70 140 150 1.62
100 60 120 200 1.65
250 1.77
150 50 100
8 0.63
200 50 100 14 0.75
250 47 95 22 0.84
38 0.99
(CV cable 6,600) 6.6KV 3Core 60 1.17
(3 ∅3W) 100 1.41
150 1.65
200 1.62
250 1.65
● 지락보호에 대해서도 과전류계전기와 같이 전력회사의 보호방식에 ● For the protection of ground fault, as in overcurrent relay,
대응하여 수용가측에서는 시한협조 및 지락전류 협조를 가질 필요 consumer shall have time and ground fault coordination
가 있다. corresponding with suppliers protective measures
● 특히 파급사고의 대부분이 지락사고에 따른 것이다. 그러므로, 적어 ● Most of ground faults are caused by influension effect.
도 ZCT부터 부하측에서 발생하는 것은 모두 수용가 측에서 차단하 There fore consumers shall take action to break down
는 것이 필요하다. grounding from the ZCT burden
● 운용상에 있어서는 전력회사와 충분히 연락을 취하여 협의할 필요 ● For the managing ground fault, consumer ends shall
가 있다. coordinate fully enough with power supplier.
● 일반적으로는 현행의 수용가용 고압지락계전장치는 한시적으로는 ● As a rule HVGR which consumer use, operates timely
문제가 없고 감도전류치를 적절히 선정하는데 따라서 대개의 경우 without any hitch. By choosing sensitivity properly. HVGR
배전용 변전소의 지락보호계전 장치와 협조가 된다. coordinates smoothly with, protective ground relay in
distribution purposed-power plant.
지락보호 구성 Construction
● 지락보호를 하는데 있어서의 방식은 방향을 선택하여 차단하는 ● In protection of ground fault, there are two kinds of relay :
DGR이 있으며, GPT의 영상 전압만으로 동작하는 OVGR이 있다. DGR for directional Selection and OVGR toroperating with
● OVGR은 전압요소에 따라서만 동작하기 때문에 보통 과전류계전기 Zero voltage from G. P. T.
와 같이 동작전압치는 가변되는 탭(일반적으로 25~60V)과 동작시 ● OVGR operates in accordance with voltage and time
간을 변경하는 레버가 있어 가변이 가능하다. adustable Knob, each.
● 지락계전장치의 감도는 JIS (고압지락계전장치)에서는 200mA, ● High voltage ground relay shell be provided as following
400mA, 600mA 3점의 절체탭을 반드시 구비하여야 한다. (연속 sensitivity Tap according to JIS 200mA, 400mA, 600mA
절체는 안된다.) ● The setting taps shell be fixed taps, not be linear sliding
● 예를 들면 235mA 또는 422mA와 같이 슬라이드 저항 등으로 미 type like 235 or 422 instead of 200mA or 400mA.
소한 변화를 주는 것은 JIS에서는 불가로 되어 있다. 연속가변이 아 ● Operating time : Overcurrent Setting Valus 130%-
닌 탭을 부가하여도 관계없다. 0.1~0.3secs, 400%-0.1~0.2secs. Based on the above
● 동작시간은 과전류정정치의 130%에서 0.1~0.3초, 400%에서 characteristics. HGR seems to be inverse time
0.1~0.2초로 되어 있다. 이 특성에서보면 반한시 특성을 가지고 있 characteristic. But it is definite time characteristic.
는 것 같이 보이나 실제는 정한시에 가깝다.
Block diagram
Wiring
Terminal arrangement
Dimension
● Digital type non draw out / Static type DGR, POR, HGR
선박용 계전기
VOLT/Hz, PFR, PSI, SYNC
선박용 3-Phase Voltage and Frequency Relay
DFV-011
특징
단상 전압 및 주파수 계전기로 High-Low setting이 가능하고 한
Unit에 내장되어 있어 전압과 주파수 콘트롤이 동시에 가능합니다.
Specification
DFR-021
특징
3상에 흐르는 부하전류를 검출하여 정상상태에서 불평형 및 결상상태가 될 시
즉시 정밀차단하여 모터의 소손을 미연에 방지, 보호하는 계전기로 전류검출
컨버터를 조합하여 사용하는 결상계전기 입니다.
Specification
Part Name 3-Phase Phase Fall Relay
Style 매입형(Flush mounted type)
Type DFR-021
Connection 외부 CT사용, Current converter(MCT와 조합사용)
Input CT : AC5A(2차), Burden : 0.3VA
Aux. Power Voltage : AC110V, AC220V, Frequency : 50/60㎐
Aux. Power burden 7VA
Current set range AC 1~80 or 64~160A (1’
ry current of MCT 3∅)
Operating time Less than 4sec
Accuracy ±10%
Contact AC 110V 5A 30min (cos∅=1.0)
Operating temperature -10~60℃ RH < 95%
Temperature
Storage temperature -20~+70℃
Vibration Vibration frequency:16.7㎐ Double amplitude:0.4㎜ Direction:horizontal, vertical, transverse
Shock acceleration:50G Shock application direction:horizontal, vertical, transverse
Shock
Shock times : 3 times
Weight 0.5㎏
DPS-011
Feature
3상의 상위상을 감지하는 표시기로 3상위상이 정상이면 녹색(Green)
Lamp가 점등 되고 위상이 바뀌면 적색(Red) Lamp가 점등되어 정상
상태의 위상을 판별하는 표시기입니다.
Specification
DVF-011
Operation/Starting Rotation
O㎐<S㎐ � (LED)
O㎐>S㎐ � (LED)
Feature
본 Meter는 processor를 이용하여 Starting Generator의 주파수를 Operating Generator의 주파수보다 대기중인 Starting Generator의
자동 판별하여 동작하며 Starting Generator의 위상에 대하여 정확한 주파수가 높을 경우 지침(Lamp)은 SLOW 방향으로 회전하고
동작이 이루어집니다. Operating Generator의 주파수보다 Starting Generator의 주파수가
Starting Generator의 주파수가 Operating Generator 주파수보다 높으면 지침 (Lamp)은 FAST 방향으로 회전합니다.
±3Hz를 벗어난 범위에서는 지침(Lamp)이 빠르게 회전합니다. Starting Generator와 Bus의 주파수 및 위상이 같게 되면 지침
Metor의 지침(Lamp)이 움직이기 시작하는 주파수 범위는 Operating (Lamp)의 위치는 Meter 위 부분의 Marking지점(lamp)에 위치 하게
Generator의 정격 주파수의 ±3Hz 이내에야 합니다. 되는 상 동기 검출기입니다.
Specification
Dimension
DFV-011
DFR-021
DPS-011
DVF-011
ELD
누전경보기(Digital, Analog, MICOM)
D2K-ED Series Earth Leakage Detector & Relay
Feature
누전경보기설치대상물
● 소방법 시행령 제 24조 2항, 3항에 의거
누전으로인한 화재 및 재해발생예방에 경보기를 설치해야할 소방대상물
교류600V미만의 교류 전원에서의 전기설비 절연불량으로 인한 누전을 영상 변류기를 통하여 동작하는 다기능 다회로의 누전으로인한 화재발생 예방
누전경보 시스템이다. 입력의 신호중에 혼입된 각종 Noise 및 고조파를 Analog Filter 및 Digital Filter를 통하여 정상적인 신호로 변환하여 판독하므
로 정밀한 동작을 구현한다. 또한 16Bit Micro Processor를 이용하여 고속처리 및 RS-485통신기능을 부가하여 원격에서 계전기를 제어 감시할 수
있다.
1대의 누전경보 및 계전기로 8회로, 16회로, 24회로, 32회로까지 감시 및 보호할 수 있다. 기본형은 8회로로 구성되며 8회로를 내장된 별도의 Module
을 이용하면 최대 32회로까지 연결시킬 수 있다. 8회로는 기존의 경보기제품과 동일한 Case에 내장되어 호환이 가능하며 16회로, 24회로 및 32회로
는 19inch Rack의 2/3 크기의 Case를 사용한다. 누전경보 동작시 년/월/일/시/분/초 단위까지 기억되므로 사고 발생시 경보기에서 사고의 순서를 10
개 까지 확인 할 수 있어 누전으로 인한 화재감시등의 평가 수단으로 이용될 수 있다.
Display Mode
Fault Memory
고감도의 누전부터 대전류의 누전까지 정정할 수 있도록 광범위한 누전전류 Tap을 구비하고 있고, 순간 누전상태 및 동작지연 시간을 적절하게 보호협조
할 수 있도록 Time Delay 기능을 구비하고 있다.
Eather-net (TCP/IP)
Fault event
- current : 8ch, 16ch, 24ch, 32ch
- data : date, time, circuit
D2K-ED08(8circuit)
D2K-ED24(24circuit)
D2K-ED16(16circuit)
D2K-ED32(32circuit)
Front View
LED indicator
CPU(RUN)Error check
Display Auto/Manual Set
General Setting Buzzer On/Off Set
Level Setting point Communication con.
Fault check ZCT connection check
Communication Pick-up/system check
Self test mode
Key part
Key Part Up↔Down menu
Top menu modekey Right↔Left menu
Escape Key menu
Cursor menu key
Reset
Lamp and CPU reset
Menu Specification
Start on display Display Mode
- 제어전원이 인가되거나 “CPU Reset” Key를 누르면 Back - Fd(Feeder) : 감시회로
Light와 함께 아래의 Logo 화면이 5초정도 Display된 후 다음 - SC : Set Current
상태인 Display On / Off Mode나 상태 Display Mode로 자동 - ST : Set Time(Delay)
이동된다. - Curr(Current) : 현재 누전량 표시
- Default : Display On Mode - F(Fault 상태) : 누전 동작을 표시한다. (×표시)
- 상기 상태는 Scrolling하고 있으며 Up/Down 방향 Key(↑,↓)를
D E E s y s 1회 누를 때마다 1Line씩 이동된다.
D 2 K - E D S e r i e s
F d - S C - - S T - C u r r F
V 1 . 0 0 0 1 0 . 2 5 0 . 3 s 0 . 2 0
0 2 0 . 1 2 0 . 2 s 0 . 1 0
Display On Mode 0 3 0 . 4 7 0 . 7 s 0 . 7 2
- 다음의 Display 값이 5초 정도 지속된 후 다음 Mode(상태
Display Mode)로 자동 이동한다. Top menu
- 상태 Display Mode에서“MODE”Key를 누르면 다음과 같이
Top Menu가 Display 된다. 10초 이내에 아무런 Key 입력이
D i s p l a y O n M o d e
없으면 상태 Display Mode로 전환된다.
2 0 0 0 0 1 0 1 1 2 : 1 5 : 3 6
T T O P M E N U
1 . G e n e r a l S e t �
Fault가 발생된 경우 2 . L e v e l S e t
- Display On / Off Mode에 관계없이 Fault 발생시에는 다음과 ㅁ3 . F a u l t C h e c k
같이 Display 한다.
- Fault Memory창으로 이동하며 최대 10회까지 저장된다.
-“Esc”Key를 누르면 상태 Display Mode로 됨
F a u l t
F D C u r r D a t e T i m e
0 3 0 . 7 2 0 1 0 7 1 7 : 3 6
ㅁ0 9 1 . 6 3 0 1 0 7 1 7 : 3 6
Sub Menu
General Set
Display On / Off Mode 설정, Buzzer On / Off 설정,
Reset Auto / Manual 설정 / Memory Erase/ Date / Time Set
Level Set
동작 전류 및 Delay Time 설정
Fault Check
누전 발생시 Fault 확인 (누전된 Feeder, 누전 전류, 누전 발생 시
간)
Communication
통신에 관계된 항목의 설정
Test
자체동작 시험에 관한 항복 설정
System Menu
G e n e r a l S e t C u r r e n t S e t [ 0 . 5 ] A
1 . D i s p l a y [ O n ] � D e l a y T i m e [ 0 . 2 ] s
2 . B u z z e r [ O n ] A r e Y o u S u r e . ? ( Y )
ㅁ3 . R e s e t S e t [ A u t o ] Y E S : U P N O : D O W N
● Communication
M e m o r y E r a s e [ N ]
∙Top Menu에서 4. Comm set에 Cursor를 위치한 후 Enter를
Y E S : U P N O : D O W N 누르면 다음과 같이 Display 한다.
●“Each”
로 개별 설정할 경우
C O M M S E T M O D E
1 . P o r t N o . [ 0 0 ] �
S E T M O D E ( I / d t ) 2 . B a u d r a t e [ 1 9 2 0 0 ]
0 1 A [ 0 . 5 ] D t [ 0 . 2 ] ㅁ3 . P a r i t y [ E v e n ]
0 2 A [ 0 . 5 ] D t [ 0 . 2 ]
ㅁ0 3 A [ 0 . 5 ] D t [ 0 . 2 ] �
● Port No
∙각가의 Feeder에 누전 및 지락 전류를 Up/Down 방향 Key를
이용하여 입력하고 Dt는 Mode Key를 입력하고 Up/Down 방향 C o m m P o r t N o . [ 0 1 ]
Key를 이용하여 값을 설정한다. Display된 Feeder의 정정을 완 ( 1 - 1 6 )
료하면 마지막 Line 끝에 Cursor를 위치한 후 좌측 방향 Key를 H I : U P L O W : D O W N
눌러 Feeder가 Scroll 되도록 하여 Setting을 한다.
∙같은 방법으로 각 Feeder를 입력한 후 Enter Key를 누르면 다 ∙Up / Down 방향 Key를 누르면 Come Port를 설정할 수 있습
음과 같이 Display 된다. 니다.
∙Port 값이 Save 되면 위 Sub Menu로 이동한다.
S E T M O D E ( I / d t )
A r e Y o u S u r e . ? ( Y ) \ ● Baud rate
Y E S : U P N O : D O W N ∙19,200bps로 고정되어 있습니다.
T1~T8 : “a”
접점
Tcom : Common 접점
PP PN : AC 110/220V(DC110V)Aux, Power
Ta Tb Tc : 일괄 Alarm 접점
E : 외함 접지단자(E3)
Z1~Z8 : ZCT 각회로 단자(각회로와 동일함)
Zcom : ZCT 공통단자
ABG : 통신(RS-485)단자
DA: (+), DB(-), DG(통신접지), 통신용접지는 외함 접지단자와
분리하십시요.
Wiring
T1~T32 : “a”
접점(각회로와 동일함)
Tcom : Common 접점
PP PN : AC 110/220V(DC110V)Aux, Power
Ta Tb Tc : 일괄 Alarm 접점
E : 외함 접지단자(E3)
Z1~Z32 : ZCT 각회로 단자
Zcom : ZCT 공통단자
ABG : 통신(RS-485)단자
DA: (+), DB(-), G(통신접지), 통신용접지는
외함 접지단자와 분리하십시요.
Dimension
�8C
누전경보기 지락검출계전기
(Analog/MICOM) (Analog/MICOM)
-Theaters, Stadiums
-Dorm Inatories All lines below same as above All lines below same as above
-Hospitals
-Kindergartens
-Bathhouseds
-Passenger’
s waiting rooms
-Multi-family housings of 4 stories and up All lines below same as above All lines below same as above
-Schools
-Exhibition halls
-Garages All lines below same as above All lines below same as above
-Hangars
DED-M10
특징 Features
1. 집합형 누전 경보기는 다회로의 누전을 동시에 감지하여 경보 또는 1. Multi type earth leakage detector has alarm or CB trip
차단기를 Trip시키는 기능으로 구성되어 있습니다. function with detecting multi circuit leakage.
2. MCU (A/D converter)내장을 주회로에 장착하여 선로 점검에 필 2. As equipped with MCU(A/D converter) at main circuit, it is
요한 기능을 디지털로 표지하여 주는 다기능 누전 경보기입니다. multi function earth leakage alarm unit with digital display
3. 고장 선로 및 누전 전류량을 연산하여 DISPLAY 에 표시, 확인할 for detection circuit.
수 있고, 복구 조치에도 용이 합니다. 3. Available to check leakage current armount and leakage
4. 자기 감시 기능을 수용하여 동작에 안정성을 기하였으며 다양한 lines.
LED 표시 기능으로 수신기의 동작 상태를 쉽게 판별할 수 있습니 4. As equipped with self detecting system, easy to check
다. operation condition stably with various LED indication
5. 자체 시험 스위치 및 도통 스위치를 사용하며 자체적으로 내부회로 function.
를 검사할 수 있습니다. 5. Self detecting and checking system make it be easy to
inspect internal circuit.
Front plate
Performance Features
1. Being a set type leakage detector, it sets and monitors 5) Leakage level indicator displays lever of leakage in
plural number of line circuits simultaneously and features a mA nuit.
combination of power supply and alarm system in a unit. Note 1 : When Cont/Auto switch is set to auto. position,
2. According to line monitoring instruction from MCU, it warning lamp(Yellow LED) will blink and when
monitors all lines hooked simultaneously. the leakage stops, all warnings and alarm will
3. In case leakage is developed in any monitored line, the be canceled.
residual current transformer generates voltage which is Note 2 : When buzzer on/off switch is set to off position,
fed to the leakage detection circuit of receiver as an input. warning lamp(Yellow LED)will blink and will not
4. The input is amplified and then fed to MCU for processing. alarm if the leakage exceeds the critereon.
5. At MCU, amplified input is converted by A/D converter 6. Clarification of warning indications in case two or more
for comparison against the voltage one of selected lines is leaking concurrently, the leaking line indicator
sensitivity. And if a ratio higher than predetermined value lamps of such line will all light concorrently, but the
is obtained, warnings become activated as follows ; leaking line number indicator and leaking level indicator
1) Alarm lamp(Red LED) turns on. will display the value of first detected line only. Leaking
2) Buzzer-alarm. level of other lines can be checked by pressing the line
3) Leakage fault line indicator lamp(Red LED) of subject test switch(Tact type).
line turns on. 7. Reset if Cont/Auto switch remains after the leakage is
4) Leaking line number is circuit indicator. removed, reset to cont, position.
경보기를 설치하기전 다음 사항을 점검하여, 경보기의 기능을 확인 5. 다음은 회로시험 및 ZCT 도통 스위치를 회로별로 눌러 회로 시
하시기 바랍니다. 험을 합니다. 각 회로별 스위치를 누르면 회로별 누전표시 LED
와 경보 LED가 점등되고 누전회로 표시 디지탈에는 해당회로,
1. 수신부의 P0, P1 단자에 전원 전압(AC220V)을 연결하십시오. 만 누전량 표시 디지탈에는 999 를 표시합니다. 개별 시험 후 복
약 AC 110V를 사용하실 경우 뒷면의 슬라이드 스위치를 AC 귀 S/W를 눌러 초기상태 복구시키십시오.
110V로 전환 조정하여 사용하십시오.
6. 지속/자동 S/W를 자동(LED 점멸상태), 부져 On/Off S/W를
2. 전원을 연결한 후, 뒷면의 On/Off 스위치를 On으로 설정하면 전 Off(LED 점멸상태)로 설정하고 5항의 시험을 행하십시오. 이때
원 투입상태 (전원 LED 점등)가 됩니다. 부져는 울리지 않고 모든 표시 장치는 자동으로 환원됩니다.
(주의 : ZCT 도통 LED(황색)는 회로별 단자에 ZCT를 접속한 후
3. 회로검사 스위치(TACT)를 눌러 디지털 표시를 점검합니다. 스위 도통 스위치를 눌러야 점등합니다.)
치를 누를 때마다 누전 회로 표시가 1회로씩 순차적으로 변환되
고 누전량은 000 을 표시합니다. 스위치를 누르지 않고 약 5 7. 이상의 시험이 끝나면 On/Off를 Off로 한 후 전원을 제거하십시오.
초가 경과하면 자동으로 표시가 소멸됩니다.
The following points should be checked before installation continuity indicator lamp(Yellow LED) At that times the
to ensure operability. display of leaking line indicator changes the display
sequence by with steps by one at each time when the
1. Connect control power(AC 220V) to terminals P0 and P1 switch is pressed and leakage level indicator will
of ELD(Note: Since the control power is set to AC220V at unchange to show Adn thus check of digital segment is
factory on delivery, convert slide switch on the back of accomplished.
ELD to AC110V if it is used AC110V for control power)
5. Check lines by pressing line test and ZCT continuity
2. After connecting control power to the terminals, set switch. When line test switch is pressed, line leakage
power on/off switch to "on" position to energize the indicator LED and alarm LED turn on. And leaking line
detector(Red LED turns on). number indicator will display leaking current of subject
line number. After checking all items, return in initial
3. Check digital display of leaking line number indicator stage by pressing the return s/w
and leaking level indicator by pressing line test
switch(Tact type). Every time the switch is pressed the 6. Repeat checks of paragraph 5. set Cont/Auto switch to
line number on display advances to very next higher Auto. Position(LED blinks) and buzzer on/off switch to
number in burn and the leakage level indicator will off(LED blinks). At this time, the buzzer does not sound
display zeros. After an elapse of about 5 minutes without and all indicators return to automatically.(Note: ZCT
additional pressing, the indications will disapear continuity indicator LED (Yellow) will turn on only when
automatically. ZCT is connected before the continuity test is performed.)
4. Check intenral circuits by pressing selftest switch. If the 7. After completion of all check ups in preceeding
switch is pressed, all displays and alarms turn back paragraphs, set the power on/off switch to 'off' and take
initial stage automatically one by one except the off control power from the terminals.
1. 설치하고자 하는 장소에 수신기의 치수에 맞게 제작 설치합니다. 1. Arrange a mounting panel suitable to the receiver and
2. 경계선로에 ZCT를 선정합니다. install it on the desired location
1)부하용량에 맞게 ZCT를 선정합니다. 2. Install ZCT on lines to monitor.
2)대전류 모선 혹은 강한 자장으로부터 10cm 이상의 위치에 설치 1) Select ZCT of adequate capacity for each line.
하여 주십시오. 2) install ZCT lotated at 10cm or more distance current
3) 단상,3상 구별없이 부하 선로에 설치합니다. bus or strong magnet field
4) 3상 4선식인 경우도 중성선을 포함 4선을 모두 ZCT에 관통시 3) Install ZCT on load side whether the power supply is
킵니다. single phase or 3 phase.
3. 수신기 뒷면 단자 결선 4) In case of 3 phase 4 line system. all 4 lines including
1) 변류기측 2개의 단자 중(단자의 극성구별은 없음) 1개는 수신부 the neutral should go through the ZCT.
각 회로 단자 ①. ②, ③, ④, ⑤, ⑥, ⑦, ⑧, ⑨, ⑩에 결선하고, 3. Connections to terminals on back of receiver
1개의 단자는 공통단자로 수신부 ⓩ 공통단자에 연결합니다. 1) The one terminal of ZCT,s two terminals (not distinction
2)단자 Ta,Tc(무전압접점)는 외부에 부져를 설치시 연결합니다. of the polarity) should be connected to line terminals ①,
3)단자(E)는 접지단자로 배전반 그라운드로 연결하십시요. ②, ③, ④, ⑤, ⑥, ⑦, ⑧, ⑨, ,⑩ and the other terminal
4. 수신기의 전원은 다른 회로 전원과 병렬로 연결하지 마시고 분기이 which is the common shall be to common terminal ⓩ of
전의 별도 전원을 사용해야합니다. the receiver.
2) The Terminal Ta and Tc(no voltage contacts) are used
when a buzzer is installed on the outside.
3) The terminal E for grounding should be connected to
the grounding terminal of distribution board.
4. The control power of receiver should be connected an
independent source which is not distributed from main
source
1. 전원등이 점등되었는지 확인합니다. 1. Check whether the power lamp is turned on or not
2. 회로 시험 및 ZCT도통 스위치를 약 1초간 눌러 각 회로별 동작상 2. Press circuit test switch and ZCT continuity switch
태 및 해당회로의 ZCT 도통 LED가 점등되는지 확인합니다. during about one second and Check whether circuits
만약 점등되지 않을 시에는 해당 단자의 연결상태를 점검하시기 바 are in normal status and ZCT continuity indicator lamp
랍니다. turns on. If the lamp do not turn on, please check up
3. 복귀 스위치를 눌러 수신부의 전기능을 초기감시상태로 환원시킵니 the connection of respective terminals.
다. 3. Please Initialize entire receiver function by pressing
4. 회로 검사 스위치를 눌러 각 회로의 누전량을 확인하시기 바랍니다. reset button.
5. 회로에 기준치 이상의 누전이 발생했을 시, 누전회로 표시 디지털과 4. Check levels of leakage on each circuit by pressing
누전량 표시 디지털에는 최초의 누전 전류값이 표시되고 회로별 누 circuit test switch.
전 표시등에는 고장 회로가 전부 점등됩니다. 5. In case of a leakage exceeding the criterea, leaking
6. 회로의 누전량이 1.0A를 초과할 경우에는 999 를 표시합니다. circuit number indicator and leakage level digital
indicator will display the first detected leaking circuit
number and its level of leakage while leakage fault
indicator lamps will indicate leaking lines individually.
6. If the leakage level exceeds 1.0A, the 999 will display
on the leakage level indicator.
DED-A10
동작 특성 설명 Performance Features
전기적 환경에 대한 서지보호 대책으로 전자기 적합성 시험을 필한 제 1. In case of leakage, output voltage that is induced in the
품으로 어느 환경에서나 사용가능하며 전기적 환경에 대응할수 있는 current transformer is storaged to leakage detection circuit.
회로를 추가하여 제작된 제품입니다. 2. Receiver adjusts input voltage deriving to leakage to
sensitivity scale for comparison with the criterion. And if the
1. 선로에 누전이 발생하면 해당 선로 변류기의 출력 전압이 누전 검출 value is determined to be exceeding the criterion, it
회로에 입력되어 집니다. generates warning and alarm as follows.
2. 수신부는 누전 검출 전압을 감도 조정 회로에 의해 재조정한 뒤, 비 1) The alarm lamp(Red LED) turns on.
교 판정을 하고 기준치 이상이 되면 다음과 같이 경보 표시 합니다. 2) The buzzer sound on to sign the fault.
① 경보등(적색 LED)을 점등합니다. Note : If buzzer on/off switch is set to off, position buzzer
② 부져를 동작시켜 경보합니다. on/off lamp will blink without sounding.
(주의 : 부져 on/off 스위치를 off로 설정하였을 경우에, 부져 3) Leaking circuit indicator lamp (Red LED) of the
(on/off 주의) 등이 점멸하고 부져는 동작하지 않습니다.) applicable circuit turns on or off.
③회로별 누전 표시등(적색 LED)의 해당 회로가 점등됩니다. Note : If Continue / Auto switch is set to Auto position,
(주의 : 지속/자동 스위치를 자동으로 설정하였을 경우에는 지속/ continue / Auto warning lamp will blink. When the
자동주의 등이 점멸하고, 누전이 복구되거나 없어졌을 때 자동적 leakage is stopped or the circuit is recovered to
으로 위 ①,②항의 경보표시가 소멸됩니다. normal state, the alarms of subparagraphs 1) and 2)
3. 복귀(Reset) will automatically disappear.
선로의 누전상태를 보수한 후 지속/ 자동 스위치가 지속으로 설정 3. Reset
되어 있을 경우에는 복귀 스위치를 눌러 수신부의 기능을 초기 상 If Continue / Auto switch is set to continue position, press
태로 환원합니다. reset button to initiaize receiver function as soon as the
leakage defect is removed.
※ 경보기를 설치하기전 다음 사항을 점검하여, 경보기의 기능을 확인 Note : Check following items to ensure normal function of the
하시기 바랍니다. device before installation
1. 수신부의 P0,P1 단자에 전원 전압(AC 220V)를 연결하고 뒷면의 전 1. Connect power line (AC 220V) to terminals P0 and P1 of
원 on/off 스위치를 on으로 설정하십시요. the receiver and set power on/off switch to on position.
(경보기의 전원 전압은 공장 출하시 설정치가 AC 220V입니다. 만 (The power is set to AC 220V at factory for delivery. If AC
약 AC 110V를 사용하실 경우 뒷면의 슬라이드 스위치를 AC 110V 110V is used, set the position of selector switch to AC
로 전환 조정하여 사용하십시오.) 110V position.)
2. 전원등 (녹색 LED)이 정상적으로 점등되면, 회로 시험 및 ZCT 도 2. When power lamp (Green LED) is turned on to indicate
통 스위치를 회로별로 눌러 회로시험을 합니다. 각 회로별 스위치 normal status, carry out circuit tests by pressing circuit test
를 누르면 회로별 누전 표시 LED와 경보 LED가 점등되고 경보음 switch and act continuity switch for each circuit. When
이 울립니다. 개별 시험후 복귀 스위치를 눌러 초기상태로 복귀시키 circuit test switch of a line is pressed, leakage indicator
십시요. LED and warning LED of the circuit turn on with alarm.
When the test is over, intialize all the funclion by pressing
3. 2의 시험을 지속/자동 스위치를 자동에, 부져 on/off S/W를 off로 reset button.
설정하고 재차 행하십시요. 이때 부져는 울리지 않고 모든 표시장치
는 자동으로 환원됩니다. 3. Repeat the testing explained in above paragraph 2 with
(주의: ZCT 도통 LED는 회로별 단자에 ZCT를 접속한 후 도통 스 Cont/Auto switch that is set to Auto position and buzzer
위치를 눌러야 점등합니다.) on/off switch that is set to off position. In this instance.
/and buzzer will not sound and all the indicators will return
4. 이상의 시험이 끝나면 뒷면의 on/off 스위치를 off 상태로 전환한후 to normal status automatically.
전원을 제거하십시요. (Note : ZCT continuity LED will light only when ZCT is
connected to circuit terminals and continuity test switch is
pressed).
1. 전원등이 점등되었는지 확인합니다. 1. Check whether power supply lamp is turned on or not
2. 회로시험 및 ZCT 도통 스위치를 눌러 각 회로별 동작상태 및 해당 2. Press circuit test switch and ZCT continuity switch. And
회로의 ZCT도통 LED가 점등되는지 확인합니다. 만약 점등되지 않 check whether if circuit state indicator lamp and ZCT
을 시에는 해당 단자의 연결상태를 점검하시기 바랍니다. continuity indicator lamp of the circuit turn on. If no, check
connections of terminals.
3. 복귀 스위치를 눌러 수신부의 전기능을 초기감시상태로 환원시킵니
다. 3. Initialize the performance of receiver by pressing reset
button.
Specification
Features
1. Multi-ground fault relay(GFR) is multi-functional and is able to detect multiple ground faults of monitoring circuit and is displayed
leakage in the circuit and fault current when earthing.
2. It is installed 8 bit MCU with A/D conventer and is configured to perform advanced functions for high relability.
3. It is a collective device that is intergrated many ground fault detector of conventional single unit.
4. It is capable to detect from minor grounding fault current(0.1A) to medium level fault current (10A)
5. It is configured to have operating time taps for adjustment of time setting is easy for protection coordination of distribution circuit
6. As wide display and indicators, it is able to enhance checking up and performance.
7. Watch dog function assures error - free operation.
8. The memory stores the last record of ground fault current of each circuit to facilitate following up in the event of accidents.
9. The ABS casing newly adopted offers improved durability and extended life of product.
10. All GFRs are tested EMC to ensures and high frequency & surge do not interfere design performance of GFR.
Front plate
※ 주의사항
∙DGF-M10T, M05T 제품은 Breaker 차단용으로 Aux, Relay Board와 조합하여 사용하십시요.
∙DGF-M10, M05 제품은 경보 또는 Breaker 차단용을 위한 내장형으로 Aux, Relay Board 사용이 불필요합니다.
Outline Information
1. 집합형 누전 검출계전기는 여러 회로를 집합하여 동시에 감시하 6. 표시확인 : 두개이상의 선로에 지락사고가 발생하였을 경우, 회로
며 지락전류량 표시와 사고전류량 표시기능이 함께 내장된 계전 별 지락사고 표시등은 전부 점등하지만 지락선로표시 디지털과
기입니다. 지락전류량 표시 디지털에는 가장 먼저 지락사고가 발생한 선로
의 값만 표시합니다.
2. MCU의 선로감시 명령에 의해 모든 경계선로를 동시에 감시합니 다른 선로의 값을 확인하고자 할 때에는 회로검사 스위치를 눌러
다. 각 회로의 지락전류량을 점검할 수 있습니다. 만약 자동복구 상
태에서 이미 사고전류량이 소멸된 경우에는 HOLD CHECK 스위
3. 경계선로에 지락전류가 발생하면 영상변류기에서 전압이 출력되 치를 눌러 메모리된 사고전류량을 확인할 수 있습니다.
어 계전기의 지락전류검출회로에 입력됩니다.
7. 복귀(RESET) : 선로의 사고를 보수한후 자동/수동 스위치가 수동
4. 입력전압은 증폭처리된후 중앙처리장치에 입력됩니다. 으로 설정되어 있을 경우에는 사고 표시가 지속되므로 복귀스위
치를 눌러 계전기의 기능을 환원시켜야 합니다.
5. 중앙처리장치는 증폭된 입력전압을 A/D로 변환하고 감도전류설
정값과 비교하여 설정값 이상이 될 때 다음과 같이 동작합니다.
① 동작시간정정치가 경과한후 해당회로의 지락 사고표시등이 점
등됩니다.
② 해당회로의 REPLAY가 동작합니다.
③ 지락전류량 표시디지털에 지락전류량이 숫자로 표시됩니다.
※ 주의 : 자동/수동 스위치를 자동으로 설정하였을 경우 적색
LED가 점등되고 지락전류가 소멸될 경우 자동적으로
발생한 모든 동작표시가 없어집니다.
동작특성
1. Multi-ground fault relay monitors a number of circuits 6. Identification of indications : When leakages occur in
collectively and carries built-in functional arrangement for plural number of circuits on sometime, ground fault
ground leakage level indication and fault current level indicator lamps for applicable circuits will light up at
indication. once. But ground fault circuit number indicator and
ground fault current level indicator will display the value
2. It performs monitoring of all circuits consequently by the of first circuit detected. The values of other fault circuits
command of MCU. can be checked by pressing circuit test button of
respective circuit. If it is the auto reset mode, fault
3. In case a ground fault current developed, it induces a current has been cleared. Such fault current can be
voltage in ZCT which is fed to ground fault current read out from the memory by pressing hold check
detection circuit as an input. button.
4. After Input signal(voltage) is amplified, and then it is 7. Reset If Auto/Manual switch is set to manual position
supplied to CPU for processing. after the ground fault is repaired, press reset button to
initialize the performance or else fault indication will be
5. CPU converts input by A/D converter for comparison to kept on.
set value of sensing current. And, if it is found more
exceeding the setting value, it is performed as followings.
1) Turns on ground fault indicator lamp upon the elapse
of setting interval of operating time.
2) Activates GFR or the circuit.
3) Indicates level of ground fault current on ground fault
current indicator in numeral value.
※Note : If Auto/Manual switch is set to Auto position the
warning lamp(Red LED) turns on, and the fault is
repaired, all operating indication of the circuit
will disappear automatically.
(계전기를 설치하기전 다음 사항을 점검하여 계전기의 기능을 확인 5. 지락감도설정 확인스위치를 눌러 각 회로의 감도전류설정을 확인
하시기 바랍니다.) 하십시요.
1. 계전기의 P0, P1 단자에 전원전압(AC 110V 또는 220V)를 연결하 6. 회로별 자체시험스위치를 눌러 계전기의 내부회로를 점검합니다.
십시오. 스위치를 누르면 해당 회로의 RELAY와 지락사고등(RED LED)
(주의: 계전기의 전원전압은 공장출하 설정치가 AC 220V입니다. 이 동작되며 지락전류표시 디지털에 20.5 를 표시하여 각 회로
AC 110V를 사용하실 경우 뒷면의 슬라이드 스위치를 AC110V로 의 이상유무를 확인합니다. (디지털 표시는 가상의 지락상태를 표
전환 조정하여 사용하십시요.) 시하며, ZCT의 연결이 안된 상태에서의 숫자임)
2. 전원을 연결하면 전원등(GREEN LED)이 점등되어 전원 투입상 7. 자동/수동 스위치를 수동으로 설정하고 6. 항의 시험을 다시 행하
태임을 알립니다. 십시요.
3. 회로검사 스위치를 눌러 디지털표시를 점검합니다. 8. 이상의 시험이 끝나면 복귀스위치를 눌러 계전기를 초기상태로
스위치를 누를때마다 회로표시가 1회로씩 순차적으로 변환되고 환원시킵니다.
지락전류량은 888 을 표시합니다.
스위치를 누르지 않고 약 25초가 경과하면 자동으로 표시가 소멸
됩니다.
Check up following points befor installation in order to 6. Check up internal circuits by pressing self- test button of
ensure satisfactory performance of GFR. each circuit.
If the button is pressed of a circuit, relay of the circuit
1. Connect AC 220V power lines to terminals Po and P1 of and ground fault indicator lamp(RED LED) and circuit
GFR. indicator relay activate to show status of circuits.(The
※Note : Operating power is set to AC 220V at factory value of digital display represent assumed state of
when delivered. If AC 110V is used, slide the grounding fault).
power voltage selector switch to AC 110V
position. 7. Carry out the test of item 6 after auto/manual switch is
set mannual position.
2. When the power os connected, power lamp(Green LED)
turns on to indicate power suppy. 8. Return to the initial status by pressing the reset switch
after finishing the above test.
3. Check up digital displays by pressing circuit test switch.
The circuit number on display changes by advancing
one circuit at each of pressing the button and ground
fault current level indicator will remain displaying
888 all the while of testing. After an elapse of about
25 seconds or so without pressing test button further, the
indication will disappear automatically.
② 대전류모선 혹은 강한 자장으로부터 10Cm 이상의 위치에 설 ② 계전기의 ⓐ~ⓘ 단자는 외부 릴레이 접점(a접점), COM 단자
치하여 주십시요. 는 외부 릴레이 공통 접점(c접점)으로 차단기구제어, 외부 경
보용 부져 및 중앙감시반 누전사고표시장치에 이용됩니다.
③ 단상/3상 구별없이 부하선로에 설치합니다.
③ Ta, Tc 단자는 외보용 INDICATOR(부져, LAMP) 사용 접점
④ 회로별 자체시험스위치를 눌러 계전기와 ZCT와의 단선유무를 입니다.
검사합니다.
④ 단자(E)는 접지단자로 배전반 그라운드로 연결합니다.
정격전압 5% 이내에서 ZCT가 계전기에 정상적으로 연결되어 있
을 시에는 지락전류량 표시디지털에 18미만의 숫자를 DIGTAL로 ⑤ 계전기의 전원은 다른 회로전원과 병렬로 연결하지 마시고 분
표시하고 단선시에는 18이상 숫자를 표시하였을 경우 수신기는 기이전의 별도 전원을 사용하십시요.
정상입니다.
1. Fabricate relay mounting panel of a suitable size and fix ② With GFR, terminals ⓐ through ⓙ are‘a’contacts for
it on which GFR be installed. Then install ZCT on the external relays, and terminal COM is ‘contact’ for
circuits being monitored. external relays. The terminals could be used for
control of circuit breakers, external alarm buzzer, and
① Install ZCT of adequatable for the load (For selection leakage fault in dication on central control board.
of ZCT specification and current rating. use ZCT
manufactured by us for ELD.) ③ Terminals Ta and Tc are provided to use the
contacts for external indicators(buzzer, lamp).
② Ensuring GFR is in stalled at 10cm or more distance
where there are large current bus and strong magnet ④ Terminal (E) is for grounding which is connedted to
field. the ground terminal of distribution board. (Refer to
external wiring diagram for connections).
③ Install GFR on load circuit of single phase and three
phase power without exception. ⑤ The control power of relay should be connected an
independent sonrce which is not distributed from
④ check confinuity between GFR and ZCT by pressing main source.
self-test button of each circuit line. The receiver is in
nomal status if ground fault current level indicator
shows a value in numerals Below of 18 if the
connection of GFR and ZCT is correctly made, and a
value of 18 if they are disconnected.
Contact output type(Alarm & CB Contacts) Signal output type(CB Trip Contacts)
Aux relay board is a power relay which controls output power according to
the input signals of industrial uses, and consists of set type relays controlling
MCCB or MC coils.
Features
�Ensure to use Aux Relays (DRB-010. 005) when DGF-M10, M05 are used to
drive MCCB and trip rather than the using them as central control board lamp
indication.
�It is insulated completely between and among input, output, and power lines.
�Single board is capable to control 5or 10 circuits
�Formerly exposed aux relays are now internally located in order to prevent
mal-functioning caused by moisture hazardous to insulation.
Specification
특징 Features
이 정지형 접지검출계전기(GFR)는 ZCT(영상변류기)와 조합하여 접지 The static GFR with a sensor(Toroidal CT) is for ground
전류를 검출하며, 그 고장회로의 차단기를 차단하거나 경보를 울리게 fault current detection and has an output contact for a fault
할 수 있도록 출력접점을 내장하고 있습니다. 이 사양서에 표시된 동 circuit trip. The relay is combined with a sensor which is
작전류란 ZCT의 1차에 흐르는 전류를 의미합니다. 즉 이 ZCT 1차에 calibrated as a set. The operating current in the
흐르는 전류를 기준으로 정정해야 하는데 이와 같이 정정된 전류가 specification means 1ry current of the CT. While the 1ry
ZCT 1차에 흐르고, 설정된 시간이 지나면 계전기의 출력(트립용 또는 current is reached at set value. the output of the relay is
경보용) 접점이 붙게 됩니다. closed.
센서 ZCT의 2차는 GFR과 직접 연결되므로 발주시 한 조로 주문하는 Since the 2ry output of the sensor is connected to the input
것이 바람직 합니다. 모델“F-xx는 배전반 표면 부착용(플래쉬 마운팅 of the relay. it is recommended that the relay with a sensing
타입)이며, P-xx는 판넬 내장형으로 수분리형입니다. 자세한 내용은 CT has to be ordered as a set. Model.“-F□□”is for semi-
이 매뉴얼의 관련 부분을 참조하시기 바랍니다. flush mounting type and“-P□□”is for pin type with a base
socket. Refer to the drawings in the instruction for more
information.
이 접지계전기(GFR)는 비접지 회로망에서 회로에 흐르는 영상전류(Io) The GFR may be applied where fault circuits should be cut
및 접지시 모선측에 발생하는 대지간 불평형 캐패시터 성분에 의한 전 off detecting current, lo and unbalanced current. Ic in the
류(Ic)가 ZCT를 통하여 흐르는 량을 감지하여 검출하는 방식입니다. non-grounding network. Capacitive components existing in
평상시 평형을 이루고 있던 3상간의 대지간 평형 정전용량이 일선 지 the bus side from ZCT is balanced between earth and three
락으로 인하여 깨지면서 대지간 캐패시터 성분에 의한 불평형 전류가 phase conductors at the normal condition. The balanced
발생 되는데 이 전류가 ZCT를 통하여 흐르게 됩니다. 접지전류(Io + capacitive components of three phases are broken as soon
Ic)정정 및 동작시간 정정은 명판위에 있는 로타리 스위치로 설정 할 as for one of three phases being grounded. And then the
수 있습니다. 이 로타리 스위치의 <LOCK> 위치에 맞추어 놓으면 이 capacitive current becomes to flow thru the ZCT. The fault
기능은 작동하지 않습니다. 기능중 Manual(수동) 및 Auto.(자동) 선택 current(lo + lc) can be set by rotary switches on the front
스위치가 있으며, Manual로 선택하면 접지 현상이 제거되어도 계전기 plate of the relay. Time delay function is selected by the time
의 접점은 운전원이 RESET 스위치를 누를 때까지 지속적으로 붙어 switch as well. By turning to <LOCK> of the rotary switches for
있으며, AUTO로 선택하면 계전기에 접지가 제거되면 자동으로 출력 operating current and/or operating time, the function(s) can
접점이 복귀됩니다. be disabled. Reset function for output contact can be
selected either on Manual or on Auto.
1. 전류정정 탭 1. Current Set : There is a 9 step switch on the front plate for
0.1-0. 3-0. 5-1-3-5-7-10(A)-LOCK(총 9단계) current set. One of 8 step(0.1, 0.3, 0.5, 1, 3. 5.
7. 10(A)) and lock, can be selected.
2. 동작시간 탭
Inst.(순시)-0. 1-0. 3-0. 5-0. 7-1-2-3-LOCK(총 9단계) 2. Time Set : There is a 9 step switch on the front plate for
time set. a Instant set. 7 steps of delay time and
3. Power LED a Lock set.
보조전원이 공급되어 있으면 Power LED(초록)이 켜져 있습니다.
3. Power LED(Green) is lighted while aux. power is ON.
4. Trip LED
출력 접점이 출력 되면 Trip LED(적)이 켜집니다. 4. Trip LED(Red) is Lighted when any fault occurs and the
output contact(terminal Ta and Tc) is closed at a same
5. Manual/Auto time.
이 선택 스위치로 출력 접점을 유지하거나 자동 복귀할 수 있게 합
니다. Manual로 선택한 경우. 접지로 인하여 출력 접점이 붙었을 5. Manual/Auto switch can be selected either Manual or Auto
경우 RESET 스위치를 누르지 않는한 지속적으로 붙어있게 됩니다. for reset. “Maunal” means for manual reset of output
Auto로 선택한 경우 접지 상태가 제거되면 즉시 출력 접점도 자동 contact by pressing reset button and “Auto” means for
복귀됩니다. automatic reset of output contact as soon as the fault
current cleared.
6. RESET 스위치는 동작 표시 LED 및 출력 접점을 복귀하는데 사용
합니다.(Manual 선택시) 6. Reset button is used for resetting TRIP LED and an output
contact when Manual/ Auto switch has been turned to
7. TEST 버튼은 출력 접점 이상 유무를 확인하고자 할 때나 수동 시 Manual.
험용으로 사용됩니다.
주의: 정상 운전시 이 TEST 버튼을 누르면 접점 S.W가 Manual에 7. Test button is used for self-circuit test. If the button is
있을 때에는 접점이 계속 유지되므로 반드시 Reset S.W 눌 pressed manually, the output contact(a) is closed and TRIP
러 주십시오. LED is lighted simultaneously.
Note : Do not press the <Test> button during in service. Main
CB may be opened
2. 단자 1-3 에 보조 전원 AC110/220V를 연결한다. 2. Terminal 1 & 3 for AC 220V or terminal 1 & 2 for AC 110
aux. power is connected to a source.
3. 단상 전원의 1선만을 ZCT를 통과하게 하고 전원에 연결한다.
3. One line with an A-meter from current source is
4. 계전기에서 전류 탭은 10A에 동작 시간 탭은 0.1초에 설정한다. installed through the sensor CT.
5. 보조전원을 켜고, POWER LED가 켜졌는지를 확인한다. 4. GFR is set at 10A tap with current dial and 0.1 sec. tap
with time dial on the front plate.
6. 전류 발생 장치를 이용하여 ZCT 1차에 12A를 맞춘다.
5. Aux. power switch is "ON". Then the power LED on the
7. 전류 발생 장치에서 전류 스위치를 순간적으로 ON한다. 이 때 전류 front plate may be lighted.
가 12A가 흘렀는지 확인하고 타임 카운터가 0.1초 10%범위내에서
정지되었는지. 그리고 TRIP LED가 들어왔는지 확인한다. 6. Current through the sensor CT is set 12A (120% of set
value) using current source.
8. RESET 스위치를 누르면 트립표시용 LED가 복귀한다. 만약 AUTO
로 선택했을 경우는 출력접점은 전류 OFF와 동시에 자동 복귀되고 7. Switch current source instantaneously and watch
트립표시 LED도 자동 복귀됩니다. through-current on A-meter whether 120% of set value
is flowed. Then, confirm time on the time counter if it is
9. 다른 정정치에서도 위와 동일한 방법으로 시험 할 수 있다. counted 0.1±10%sec. (±10% of time set value) and if the
trip LED is lighted.
Dimension
1,2 : AC110V/120V
1,3 : AC220V/240V
4,5,6 : a,b,c - Contact
Low Voltage
Zero-Phase Sequence
Current Transformer
■Zero Phase Sequence Current Transformer [ZR, ZS, ZB, SZR-Series]
■Zero Phase Sequence Current Transformer [ZB-Series]
■Cable & Busbar Through Type [ZR, ZS, ZB, SZR-Series]
■Busbar Mold Type Zero Phase Sequence Current Transformer [3∅ 3W]
■Busbar Mold Type Zero Phase Sequence Current Transformer [3∅ 4W]
■How to Installation and Inspection
ZCT
영상변류기(ZR, ZB, ZS)
Zero-Phase Sequence Current Transforme [ZR, ZS, ZB, SZR-Series]
Ordering Procedure
ZR - O3O
025-25∅
050-50∅ ZR
HZR-for High Voltage Ralay HZR
065-65∅
SZR
080-80∅
100-100∅
SZR-for High sensitivity &
120-120∅
Static type Directional Ground Relay
150-150∅
200-200∅
150-150㎜ ZS
250-250㎜
600-600A
ZB4-Busbar mold type(4 wire)
800-800A
※ 주 의 : 상기 Series ZCT는 2차 출력이 전압형으로 ELD 및 Static Type ZB3
1000-1000A ZB4
Realy에 적용할 수 있는 특성을 갖고 있으며 유도형 계전기에는
적용이 불가합니다. 1200-1200A
※ Note : Because the above ZCT is voltage type on 2ry
output and has characteristics applicable with ELD 1400-1400A
and static type relay, it is impossible to apply for
1600-1600A
induction type relay.
Specifications
ZR-025
80 25 38 8 5.5 109 0.4
SZR-025 ZR,SZR type
ZR-030 200㎃/100㎷
100 30 60 14 8 109 0.5
SZR-030 (75~125㎷ at 2㏀)
ZR-050
250 50 150 80 38 109 0.7
SZR-050
Cable ZR-065
400 65 325 150 100 109 0.9
Through SZR-065
Type ZR-080
600 80 400 250 200 109 1.5
SZR-080
ZR-100 SZR Type
SZR-100 800 100 500 325 250 30㎃/50㎷ 109 2.2
ZR-120
1000 120 - 850 725 109 3.4
SZR-120
ZR-150
1400 150 - 1000 850 109 4.0
SZR-150
ZR-200
2000 200 - 109 7.5
SZR-200
Busbar ZS-150 400 30×150 ※6T×25 109 2.8
through ZS-200 400 30×200 - ※6T×25 109 3.5
type ZS-250 600 30×250 - ※6T×25 109 3.8
영상변류기(Z.C.T)동작원리
Specifications
Model Rated Current(A) Busbar Size(㎜) Zero phase current ratio Pri./Sec Dimension(page) Weight(㎏)
ZB3-400 110 4.3
400 6T×50
ZB4-400 111 7.4
ZB3-600 110 4.3
600 6T×50
ZB4-600 111 7.4
ZB3-800 110 6.6
800 6T×75
ZB4-800 111 8.8
ZB3-1000 200㎃/100㎷ 110 8.0
1000 8T×75
ZB4-1000 (75~125㎷ at 2㏀) 111 11.0
ZB3-1200
1200 8T×100 110 12.4
ZB4-1200
ZB3-1400
1400 10T×100 110 15.0
ZB4-1400
ZB3-1600
1600 10T×100 110 15.0
ZB4-1600
Round type
UNIT(m/m)
Model-No A B C D E F G H
ZR/SZR-025 25 25 87 95 110 9 30 20
ZR/SZR/HZR-030 30 25 108 100 114 7 32 32
ZR/SZR/HZR-050 50 25 131 100 122 7 32 36
ZR/SZR/HZR-065 65 26 143 114 133 7 39 37
ZR/SZR/HZR-080 80 34 174 160 180 7 40 40
ZR/SZR/HZR-100 100 38 203 160 180 7 40 40
UNIT(m/m)
Model-No A B C D E F G H Hole(�)
ZR/HZR 120 45 225 180 210 20 55 35 10
ZR/HZR 150 45 260 180 210 20 55 35 10
ZR/HZR 200 53 310 260 286 10 70 35 10
Square type
UNIT(m/m)
Model-No A B C D E F G H I
ZS-150 50 150 50 250 50 30 50 130 51
ZS-200 50 200 50 300 50 30 50 130 51
ZS-250 50 255 50 350 50 30 50 130 51
● 400-600A(80�)
Model-No A B C D E F G H I J Hole(�)
ZB3-400 50 6 300 100 100 200 160 40 188 195 6
ZB3-600 60 6 300 100 100 200 160 40 188 195 6
800-1000A(100�)
Model-No A B C D E F G H I J Hole(�)
ZB3-800 75 6 320 100 100 200 160 40 215 230 6
ZB3-1000 75 8 320 100 100 200 160 40 215 230 6
1200A(150�)
Model-No A B C D E F G H I J Hole(�)
ZB3-1200 100 8 330 140 140 280 180 35 210 260 10
1400-1600A(150�)
Model-No A B C D E F G H I J Hole(�)
ZB3-1400 100 10 350 140 140 280 180 35 210 260 10
ZB3-1600 100 10 350 140 140 280 180 35 210 260 10
400-600A(120�)
Model-No A B C D E F G H I J K Hole(�)
ZB4-400 50 180 6 35 300 100 100 100 300 210 225 10
ZB4-600 50 180 6 35 300 100 100 100 300 210 225 10
800-1000A(150�)
Model-No A B C D E F G H I J K Hole(�)
ZB4-800 75 180 6 35 320 100 100 100 300 210 260 10
ZB4-1000 75 180 8 35 320 100 100 100 300 210 260 10
Note : In case of leakage indication appears in plural at a time. check if wiring connetion is wrongly done as drawn example.
In case that circuit NO 2 is leakaged, it is normal to indicate NO 2 circuit signal only. But because common wire is not
connected to No1~No5 circuit, so No1~No5 circuits are indicated leakage singal simunltaneously.
(How to check)check the resistance between common wire and No 1 circuit~No 10 circuit. It is 30~70Ω on normal condition
and is infinity in disconnection condition.
Note : Incorrect installation of ZCT may result in malfunctioning of relay. Please refer to follwing wiring diagrams
2) Because of load current on neutral line, the current between A- 2) Cut off line B and provide class 2 grounding as required for
B cause erro operation. The relay may not activate relay ZCT.
operation in cases of leakage.
3) As load current is divided between A and B grounding, it will 3) Earth the wires before ZCT to (the side of power source).
cause missing operation in case of leakage.
4) When neutral line and distribution board line are jointly 4) Provide class 3 grounding seperately for neutral line and
connected to ZCT. malfunction will be introduced as the example distribution board each
of 3) above.
6) Occurrence of leakage will not activate relay operation. 6) Grounding of frame should be installed after(in the down stream)
the ZCT connection point.
Even if grounding is intentionally made to frame to frame, the leakage Note : The frames are transformer casing, cubicle enclosure, and
flows directly into to casing grounding without going through ZCT. structural steel frames.
MPR(4E,3E)
모터보호계전기(4E, 3E)
Motor Protective Relay
정지형 Motor-Relay의 개요 Static type Motor-Relay
● MOTOR RELAY라 함은 많은 종류가 있으나 산업설비의 전력용으 �MOTOR relays ranging wide in types refer to those relays
로서 가장 많이 사용되고 있는 것은 3상유도전동기이며 이것을 보 purposed to protect three phase induction motors that are
호하는 것을 모터 RELAY라 합니다. 모터의 보호는 중요하며 이상 prime source of motive power at most industrial facilities.
을 빨리 감지하여 부하의 피해를 최소한으로 막고 모터의 수명 및 Motor protection by means of earlier detection of fault
파손을 방지하여야 합니다. status to minimize overload damage is important for long
● 모터의 소형화, 경량화 됨에 따라 보호하는 모터 RELAY에도 고성 motor life and avoiding damages.
능, 고신뢰도가 요구되어 종래의 단순한 썸머 RELAY형에서 정지 �Ensuring with the trends of motors becoming compact and
형으로 변형되어 가고 있습니다. light-weighted, motor protection relays (MPR) being required
of high performance and reliability are featuring static state
a change from the conventional simple thermal relay
structure.
(Fig1) (Fig3)
그림2와 같이 변류기를 사용하지 아니하고 전압방식으로 결상을 검출 As shown in Fig. 2, open phase is detectable by voltage
하는 방식도 있으나 결상검출의 접속점부터 MOTOR까지는 검출이 안 method without requiring use of a current transformer. The
되며 전원측 결상이라 하여도 MOTOR의 부하가 경부하 상태의 운전 method does not, however, offer ability to detect open phase
중이면 MOTOR에는 단자전압이 걸려 있기 때문에 결상이 검출이 되 status between detector contact point to motor. In case of line
지 않는 경우가 있기 때문에 전류검출방식의 결상을 검출하는 것이 가 side open phase, terminal voltage exists if the motor is
장 바람직합니다. running with light load that open phase may not be
● 과전류 요소 만으로는 결상시 모터의 소손을 방지하지 못하는 경우 detectable. For this above reason, the current detections
가 있어 결상요소가 필요합니다. method is desirable.
● 경부하 시에는 결상이 되어도 과전류라고 할수 있는 전류가 흐르지 �Since over current measure alone may not always be able
못하므로 결상검출이 되지 않습니다. 이상을 신속히 검출하기 위하 to prevent motor burning, consideration of open phase
여는 결상요소가 필요합니다. measure will be necessary.
● 결상검출 방식은 전압 방식도 있으나 전류방식이 가장 유리합니다. �In case of running with light load, the current in phase fault
may not be large enough to be detected as over current
that status of open phase may not be detected. For this
반(역)상 검출요소(Reverse phase)
reason, application of open phase measures for prompt
● 3상유도전동기는 상순이 바뀌게 되면 모터의 회전방향이 반대로 됩 detection of phase fault will be necessary.
니다. 모터가 잠깐이라도 반대를 돌게되면 모터의 부하에 치명적인 �For this reason, use of current detection method will be
영향을 끼칠수 있습니다. most advantageous although voltage detection method is
● 그러므로 모터의 상순이 역으로 되면 즉시 검출하여 차단시키는 반 available too.
상요소가 필요합니다.
● 이 경우에는 모터의 3상 전압을 검출하여 모터의 역회전을 방지합 Element for open phase
니다.
● 그림3의 경우 마그네트 전에 반상을 접속했을 경우 반상 상태가 되 �Changes in phase sequence of three phase motor would
면 모터를 기동시키기 전에 검출하게 됩니다. reverse the direction of rotation. Revers rotation even for a
● 그러기 때문에 이 경우는 절대로 모터의 기동전에 검출하므로 안전 short time would be detrimental to the lead critically.
하게 됩니다. �Reverse phase performance for immediate detection and
● 특히 전원이 이동될 경우의 모터는 접속변경이 많으므로 이 경우에 instantaneous circuit breaking is essential whenever the
는 필히 부착하는 것이 바람직합니다. phase is reversed.
�Reverse roation is preventable by three phase voltage
Phase reverse detecting mathode(Fig2) detection.
�As shown is Flg 3. reversed phase can be detected before
starting the motor if the detector is connected before the
magnetic switch.
�The connection as such assures complete safety as it
detects reversal factor absolutely before starting.
�When power cource is changed. Installation of the detector
is highly desirable because wiring of motor may be
misconnected very often.
20A 8A 8V
40A 16A 8V
80A 32A 8V
과부하요소(OVER LOAD)
● MCT에서 반환된 DC전압을 통하여 MOTOR RELAY의 입력에
서 받아 과부하 검출이 시작됩니다. 이때 전류 정정탭에 정해져
있는 설정치이상 흐르게 되면 동작이 시작됩니다.
● 과부하 상태가 되면 시간정정에 맞는 반한시성으로 동작됩니다.
이때의 과전류 동작시간은 전류정정치의 600%의 과전류가 흐
를경우 1~40초 범위로 변화시킬 수 있습니다.
● 동작이 되면 출력 RELAY는 HOLDING 됩니다.
Fig7
반상요소
모터의 역회전을 방지키 위한 반상보호로 구성되어 전원전압(3상)을 Reverse phase
이용하여 구동시킵니다.
The relay is featured for reverse phase protection circuit and
● 전원전압의 V.W상을 이용하여 자체 MOTOR RELAY에 POWER
driven by line voltage(3�)
를 공급합니다.
�Driving power is supplied to motor relay through using of
● 과부하, 결상은 MCT(CONVERTER)를 이용하여 3E RELAY가
U-V phase of line voltage.
동작되나, 반상 검출상태는 3상의 전압을 이용하여 동작됩니다.
�In case wiring connection to W phase terminal is removed,
overload and open phase elements are activated but
reverse phase element does not.
�In case of over load and open phase, 3E relay is activated
by the power from MCT and in case of reverse phase, it is
operated by 3 phase power.
● 결선시 과부하 및 결상 방법은 MCT에서 검출된 DC �, � 전압을 �Since 3E relay is operated by power of DC voltage
가지고 3E RELAY를 동작시키므로 반상 검출이 필요치 않을 경우 detected at MCT for overload and open phase detection,
에는 U상의 결선이 필요하지 않습니다. connection of W phase is not necessary unless reverse
● M.G COIL과 계전기 V.W 전원은 동일 전원 상에 연결하는 것이 phase detection is intended.
좋습니다. �It is perferrable for MG coil and U-V ends of relay to share
● 진상용 콘덴서는 CONVERTER보다 전단에 설치하십시오. 후단에 same power source.
넣게 될 경우 3E RELAY의 전류 SETTING시에 콘덴서의 전류를 �Phase advance capacitor should be tapped on before
합성하여 정정해야 합니다. converter (at upstream). If tapped on after (close to load
● CURRENT CONVERTERDML 결선시에 �와 �의 극성을 정확히 end) the load, set current of 3E relay should include
RELAY와 결선하여 주십시오. capacitor current.
● 3E RELAY 결선시 MOTORDML 전원전압(3 ) 과 3E RELAY의 �For connection of relay to current converter, polarity of DC
전원이 U.V.W에 3� 전압이 결선되므로 사양선택시 주의하십시오. current should not be reversed.
● CONVERTER 1차측에 변류기(CT) 2차측을 이용할 경우에는 �Since three phase line voltage is connected to motor and
MCT-31을 사용해야 합니다. U-V-W phase of same line voltage is connected to 3E
relay, selection of relay should be carefully made to desired
specifications.
�When an use of CT output for converter input is intended,
MCT-31 should be used.
100 60 70 100 60 70
R:S:T=1:0.6:0.7 ( =1. =0.6, =0.7 ) R:S:T=1:0.6:0.7 ( =1. =0.6, =0.7 )
100 100 100 100 100 100
으므로 아래 표를 이용하여 부하의 불평형률에 대한(%)를 구할 수 있습니다. that unbalance ratio in percentage can be read from the table
이때 불평형률은 36%를 알 수 있습니다. at right. In the case of this example. unbalance ratio is 36% as
read from the table.
Unbalance Ratio(%)
1.0 1.0 1.0 0
1.0 0.9 0.8 12
1.0 0.8 0.7 24
1.0 0.7 0.6 36
1.0 0.6 0.65 39
1.0 0.5 0.65 51
1.0 0.4 0.75 55
1.0 0.3 0.8 66
1.0 0.2 0.85 77
1.0 0.1 0.9 95
Feature Feature
1. 3상 유도전동기가 확실하게 보호되며 과부하 결상(단상운전)및 반상 1. Protection for 3 phase motor with certain in any cases :
(역상)을 4E일 경우 지락까지 신속히 검출하여 모터의 소손을 방지 over load, single phase operating, reverse, even earth fault.
합니다. 2. Wide range of current setting and time setting in one unit.
2. 광범위한 전류정정과 시간정정을 1대로서 가능합니다. 3. Input circuit is equipped with "surge" protection circuit for
3. 입력회로에“Surge” 방지회로가 있어서 오동작의 염려가 없습니다. no error
4. 반도체 H-IC회로로서 기기오차는 물론 반영구적으로 사용할 수 있 4. Built in semiconductor H-IC circuit : And strong against
습니다. shock and vibration.
5. D4E형은 ZCT(영상변류기)를 이용하여 지락으로 인한 사고를 방지 5. D4E type protects motor from earth fault with ZCT
할 수 있습니다.
Products
Deseription 3E 4E
Cirult voltage Less than AC 600V(3∅) Primary voltgae
Rated current AC 1-80A to 64-160A, Primary current
Motor rating
Rated voltage AC 110V, AC 220V, Ac 380V(3∅)
Extent voltage 85%~110% of Rated voltage
Frequency 50/60㎐ common
Contact capacity AC 125V 10A, AC 250V 6A(cos∅=1.0), DC 30V 5A, AC 250V 3A(cos∅=0.4)
Control power AC 110V, 220V, 380V AC 110V, 220V
Power consumption
VA 3.5VA 7VA 10VA
Operating value Operation 115% of current set value(105~125%)
Operating time curve Inverse Inverse, Definite(Ground)
When over load 600% of current set Inverse:Same as 3E
Element of over load Operating time Operating time tap×1(1~10sec) Ground Fault : More than
Operating time tap×4(4~40sec) Current set value
Reset More than 100% of current set value
Operating value Less than 75% of current set value
Unbalance factor H(high sensitivity set)35±10%, L(Low sensitivity)65±10%
Element of open phase Operating time Less than 4 sec
Value of Operation Less than 80% rated voltage
Operating time Less than 1 sec
Starting Lock Starting holdtime 5sec/10sec/15sec
ON(operating) OFF(Non operating)
SL(start lock) Ambient temperature
Operating value:±10%(-10℃~+50℃), operating time:±20%
∙primary-case
Insulation resistance More than 10㏁
∙secondary-case
∙primary-case
AC 2000V 1 min
Dielectric strength ∙secondary-case
∙Mutually dry contact : AC 1000V 1min
1.2/50㎲ positive, negative polarity : 3 times
Impulse wave withstand voltage Electric circuit to case : 5㎸
Aux power to terminal : 4.5㎸
Over load P’
ry current circuit Multiple 20 of current set value
Factor Control power circuit Multiple 1.15 of rated voltage(3 Hours)
Vibration strength Viabration frequency 16:7㎐, amplitude 4㎜
Mechanical shock resistance 500㎨ (50g)
Operating current
In case setting current 16A
16 X 1,15=18.4
Overload current become
18.4A, operating start.
Manual(3E, 4E RELAY)
※ 취급상 주의 상항(Remark)
■ Reted current and penetrating turns(table 1)
1-2.5 8
2-5 4
4.-10 2
more than 8 1
취급상 주의 상황 Remark
1. 정격전류와 도체관통회수의 관계는 동작 특성상 대단히 중요함으로 1. Refer to above table 1 and decide penetration turn
상기 표1을 참고하시어 필히 지켜주시기 바랍니다. according to the using ampere carafully
2. 정격전류가 1-80A는 MCT-31을 사용하고 64-160A는 MCT-32를 2. In case of rated current 1-80A, MCT-31 can be used, and
사용하여 주십시요. in case of 64~160A, MCT-32 can be used.
3. MCT에 도체관통회수는 정격전류에 따라서 표1에 표시된 회수로 3 3. MCT penetrating wiring turns refer to table 1 and bind the
선과 다같이 같은 방향으로 설치하여 주십시요. 3 wire(3�) to same direction.
4. 고압 및 대용량의 전동기의 경우는 시판되고 있는 변류기의 2차측 4. In case high voltage and big capacity motor, normal CT'S
을 MCT에 관통시켜주십시요. secondary side should be penetrated through the MCT.
5. 3E,4E,REALY의 경우 3�전압을 정확한 상순으로 3�모두 결선하 5. In case of 3E, 4E relay, connect all the 3 phase wire to
십시요.(U.V.W) normal phase process(U, V, W).
MCT Dimension
MCT와 3E, 4E RELAY와의 극성 (+,-) 확인 MCT and 3E, 4E relay polarity(+,-) confrmation
OCR시험(TEST)보턴을 누른다. 지락 TEST 보턴을 누른다 Press OCR test button Press earth fault test
(정상시간 이상)(3E) (4E) (over setting time)(3E) butto(4E)
동작한다. Operate
정상 Normal
8. 지락전류정정 및 시험방법(4E relay) 8. How to set earth fault current and test (4E relay)
(1) 감도전류는 0.1, 0.2, 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, Lock(A) (1) Sensible current is 0.1, 0.2, 0.3, 0.5, 0.7, 1.0, 1.5, 2.0,
9Tap 입니다. Lock(A) 9taps
(2) 시간은 0.1, 0.2, 0.3, 0.5, 0.7, 1.0, 2.0, 5.0 Lock(sec) (2) Time is0.1, 0.2 0.3 0.5 0.7 1.0 1.5 2.0, 5.0 Lock(sec)
9Tap 입니다. 9taps
(3) 전류와 시간동작 후 GR TEST 보턴을 누르면 Setting 시간과 (3) After current and time setting by the pressing GR test
동일하게 동작합니다. button, it operate according to setting time.
(4) OCR동작시 OC LED가 켜지고 (4) In case operating OCR, OC LED is on and in case
GR동작시 GR LED가 켜집니다. operating GR, GR LED is on
(5) 동작후 RESET 보턴을 눌러 정상위치를 확인하지 않으면 모터 (5) Without confirmation of normal position by pressing
의 기동시 기동이 되지 않습니다. reset button, motor can't start.
(6) ZCT는 모터의 용량에 맞게 주문하시면 됩니다. (6) ZCT can be ordered with suitable capacity.
Dimension (4E)
Casing : 난연성(Non-flamable)
color : Black(N1.5)
UNIT(m/m)
Model-No A B C D E F G H
ZR/SZR-025 25 25 87 95 110 9 30 20
Dimension
[D3E]-매입형(Flush mounted)
Casing : 난연성(Non-flamable)
color : Black(N1.5)
Casing : 난연성(Non-flamable)
color : Black(N1.5)
Transducer
전력용 변환기(일반형)
Description
�DEESYS transducers are designed to accept AC current and Voltage input and provide DC proportional current and
voltage output with high accuracy.
�DEESYS transducers are compact instruments that have outstanding overload and temperature performance.
�DEESYS transducers provide high capability for long distance transmission of output, micro processing equipment and
other converters.
General specification
Head Specification
Auxiliary power AC 110/220V(±10%), 50/60㎐(1.5VA)
Input burden Less than current 0.5VA, Voltage 0.6VA
Input over capability Current rated : 1.2 In continuous
2 In 10sec
10 In 3sec
Voltage rated : 1.2Vn continuous
Description
DEESYS Voltage transducers have good linearity and low ripple output.
The elements are totally isolated among input, output, power and others to case. This voltage transducer provide proportional
DC current and voltage output which are not influenced by any load resistance, even under very low load condition, accurate
output is available with quick response.
Transducers are designed to respond to the voltage value of input but calibrated to root mean square (RMS) reading of pure
sinusoid.
■ Output Linearity
■ 3 Element ■ 1 Element
Connection diagram
■ 3 Element ■ 1 Element
Description
DEESYS Current transducers have good linearity and low ripple output.
The elements are totally isolated among input, output, power and others to case. This ampere transducer provide proportional DC
current and voltage output which are not influence by any load resistance, even under very low load condition, accurate output is
available with quick response.
Transducers are designed to respond to the current value of input but calibrated to root mean square (RMS) reading of pure
sinusoid.
■ Output Linearity
■ 3 Element ■ 1 Element
Connection diagram
■ 3 Element ■ 1 Element
Description
DEESYS Watt transducer are designed to accept DC voltage or current and provide output(VI cos�) with high accuracy and quick
response.
Internal circuit are composed entirely of high quality components and power calibration equipment for measuring exact power
energy.
∙HZ
1.60HZ
2.50HZ
■ Output Linearity
■ 3 Element
Connection diagram
■ DWT-3�3W
■ DWT-3�4W
Optional output P△, which in modulated according to the conversion method of watt and var transducer, are proportional to input
current l△ and input voltage V△.
1
Pw= ∫
T
T
O
V(t)I(t)dt
Pw=VI cosφ[watt]
Pr=VI sinφ[var]
Transducer's output linearity is depend on the transformer's primary and secondary turn ratio and phase stability. Especially under the
low load transducer should be designed to maintain the linearity within 5%~10% range, which influence transducer output complience
error.
= 1.666kW
Conversion Table
Description
DEESYS Var transducer are designed to accept DC voltage or current and provide output(VI sin∅) with high accuracy and quick
response.
Internal circuit are composed entirely of high quality components and power calibration equipment for measuring exact reactive
power.
∙HZ
1.60HZ
2.50HZ
Output Linearity
Connection diagram
DRT-3∅4W
Description
DEESYS watt/watt hour transducer are designed to measure the power and energy with various functions simultanously.
Output is adopted time division multiplication method using the R.C.
Watt hour output shall be provided various pulses according to the user's purpose and usage.
∙HZ
1. 60HZ
2. 50HZ
Output Linearity
Connection diagram
DWW-3∅4W
Description
DEESYS var/var hour transducer are designed to measure the power and energy with various functions simultanously.
Output is adopted time division multiplication method using the R.C.
Var hour output shall be provided various pulses according to the user's purpose and usage.
∙INPUT(I)
1. 0~5A 2. 0~1A 3. Option Output/Load resistance
∙INPUT(V)
1. 0~110V or 190√3 2. 0~220V or 380√3
3. Option Output Load Compliance Ϊ
0~20mA �500
∙OUTPUT(DC)
1. DC 4~20mA 2. DC 0~20mA 4~20mA �500
3. DC 0~1mA 4. DC 1~5V 5. Option 0~1mA �10K
1~5V �1K
∙OUTPUT(Pulse)
1. 1Pulse/Var hour
2. 1Pulse/10Var hour
3. 10Pulse/Var hour
4. Option
∙HZ
1. 60HZ
2. 50HZ
Output Linearity
Connection diagram
DRR-3∅4W
Description
DEESYS power factor and phase angle transducer measure the load power factor and phase angle between one voltage and
current.
According to the load condition, model shall be devided two types balance and unbalance. Balanco type's external wiring is simple.
Output Linearity
Connection diagram
Description
DEESYS frequency transducers are demonstrated in a narrow frequency band and very suitable to detect the deviation from center
frequency.
∙HZ
1. 60HZ(55HZ~65HZ)
2. 50HZ(45HZ~55HZ)
Output Linearity
Connection diagram
Description
DEESYS Analog to pulse transducers are designed to accept analog input and provide pulse output proportionally, suitable to
measure the current consumption and total integration of various process.
Model Output
∙CLASS : 0.25 DAP-
DAP-12 1000Pulse/Hour
DAP-22 1000Pulse/Hour
DAP-32 1000Pulse/Hour
∙DEESYS ANALOG TO DAP-42 1000Pulse/Hour
PULSE T/D
DAP-52 1000Pulse/Hour
∙INPUT(V)
Order made is avaliable except for standard products.
1. DC 4~20mA
2. DC 0~20mA
3. DC 0~1mA Output/Load resistance
4. DC 0~5V
5. DC 0~10V Output Load Compliance Ϊ
6. Option
0~20mA �500
4~20mA �500
∙OUTPUT 0~1mA �10K
1. 100Pulse/Hour
1~5V �1K
2. 1000Pulse/Hour
3. 10000Pulse/Hour
4. Option Output linearity
Description
DEESYS Zero sequence voltage(V0) transducers, when ground fault occur, detect the abnormal electric potential and convert to DC
output for measuring,
∙OUTPUT
Output/Load resistance
1. DC 4~20mA
2. DC 0~20mA Output Load Compliance Ϊ
3. DC 0~1mA 0~20mA �500
4. DC 1~5V 4~20mA �500
5. Option
0~1mA �10K
∙HZ 1~5V �1K
1. 60HZ
2. 50HZ Output linearity
Description
DEESYS DCmV transducers are designed to accept shunt secondary input for measuring the DC big current. DC volt transducers
convert DC source to DC current or lower voltage for measuring.
∙INPUT(V0)
1. DC 0~50mV, 2. DC 0~100mV
Output/Load resistance
3. DC 0~110V, 4. DC 0~120V
5. DC 0~150V, 6. DC 0~300V
7. ±50mV[-50mV(4mA) 0mV(12mA)+50mV(20mA)] Output Load Compliance Ϊ
8. Option
0~20mA �500
∙OUTPUT 4~20mA �500
1. DC 4~20mA 2. DC 0~20mA 2~10V �2K
3. DC 2~10V 4. DC 1~5V
5. 0~10V 6. Option 1~5V �1K
∙HZ
1. 60HZ Output linearity
2. 50HZ
Description
DEESYS Isolator transducer is used for isolating DC circuit and among various senser insulation, converting DC input to other
DC input.
Temperature tranducers(RTD) which utilize the resistance variation are designed to accept temperature measure resistance meter
output and provide proportional temperature output.
Induction Type
Protective Relay
■Induction Protective Relay
■Induction Type Over Current Relay [OCR] 50/51
■Induction Type Ground Over Current Relay [50N/51N]
■Induction Type Over, Under Voltage Relay [59] [27] [64]
■Induction Type Directional(Selective) Ground Relay [67]
유도형 계전기
OCR, OCGR, OVR,
UVR, OVGR, SGR
D OC - A - CID4
CO(OCR) for distribution C - Normal open contact
CO(OCR) for receiving I - With instantaneous unit(Non symbol has no IIT coil)
CG(OCGR) for distribution H - With holding coil
DEESYS
CG(OCGR) for receiving D - Drawout case(Non symbol D is non drawout type)
5 - 0.5-2.5A(OCGR)
4 - 4 ‐12A (According to ordering for
3 - 3 - 9A OCR setting other current taps)
2 - 2 - 6A
A - Inverse
B - Very inverse
LA-Long time(inverse)
�Voltage relay
D OV CD1
OV(OVR) C - Normal open contact
UV(UVR) O - Normal colsed contact
VG(OVGR) D - Draw out case (Non symbol D is Non drawout type)
DEESYS
1 - 110V
2 - 220V
16 - 110V(60~90V)
26 - 220V(160~190V) (According to ordering for
9 - 190V setting other voltage taps)
15 - 15V
8 - 8V
5 - 5.5V
D SG C D1
SG(SGR)
DEESYS
For DCO type characteristic of protective coordination For DOC type characteristic of protective coordination
�DCO Type
Time Rating Tap Operating Burden
IIT Unit Burden ICS Unit Weight
Charact- Type Model No Range
A Hz (A) (VA) ICS ICS+IIT (DC A) (Kg)
eristics (A)
C4 4-12 10 5.5
Non- 5
DCO-A C3 3-9 8 5.0 1.0 3.0
Drawout
C2 3 2-6 12 4.0
C D4 4-12 10 5.5
5 0.5/2.0
Drawout DCO-A C D3 3-9 8 5.0 4.0
0.1/1.0
Inverse C D2 3 60Hz 2-6 12 4.0
CI 4 4-12 20-80 10 5.5 12
Non- 5
DCO-A CI 3 3-9 20-80 8 5.0 14 1.0 3.0
Drawout
CI 2 3 2-6 20-80 12 4.0 24
CID 4 4-12 20-80 10 5.5 12
5 0.5/2.0
Drawout DCO-A CID 3 3-9 20-80 8 5.0 14 4.0
0.1/1.0
CID 2 3 2-6 20-80 12 4.0 24
C4 4-12 10 5.5
Non- 5
DCO-B C3 3-9 7 5.0 1.0 3.0
Drawout
C2 3 2-6 12 4.0
C D4 4-12 10 5.5
5 0.5/2.0
Drawout DCO-B C D3 3-9 7 5.0 4.0
0.1/1.0
Very C D2 3 60Hz 2-6 12 4.0
Inverse CI 4 4-12 20-80 10 5.5 12
Non- 5
DCO-B CI 3 3-9 20-80 7 5.0 14 1.0 3.0
Drawout
CI 2 3 2-6 20-80 12 4.0 24
CID 4 4-12 20-80 10 5.5 12
5 0.5/2.0
Drawout DCO-B CID 3 3-9 20-80 7 4.0 14 4.0
0.1/1.0
CID 2 3 2-6 20-80 12 5.0 24
�DOC Type
Time Rating Tap Operating Burden
IIT Unit Burden ICS Unit Weight
Charact- Type Model No Range
A Hz (A) (VA) ICS ICS+IIT (DC A) (Kg)
eristics (A)
C4 4-12 5.0 2.8
Non- 5
DOC-B C3 3-9 7.0 2.0 1.0 3.0
Drawout
C2 3 2-6 4.0 1.8
CD4 4-12 5.0 2.8
5 0.5/2.0
Drawout DOC-B CD3 3-9 7.0 2.0 3.8
0.1/1.0
Very CD2 3 60Hz 2-6 4.0 1.8
Inverse CI4 4-12 20-80 5.0 2.8 9
Non- 5
DOC-B CI3 3-9 20-80 7.0 2.0 12 1.0 3.0
Drawout
CI2 3 2-6 20-80 4.0 1.8 14
CID4 4-12 20-80 5.0 2.8 9
5 0.5/2.0
Drawout DOC-B CID3 3-9 20-80 7.0 2.0 12 3.8
0.1/1.0
CID2 3 2-6 20-80 4.0 1.8 14
*DOC-B : Very Inverse *2-6:2-2.5-3-3.5-4-5-6 *3-9:3-4-5-6-7-8-9 *4-12:4-5-6-7-8-10-12
Specification
inertia current setting minimun time setting 1000% of tap #10 value operating time : over 80% of nominal
characteristics operating time
temperature below ±20% in -20℃ ~ +60℃ (operating time : measuring in 300 % of input current)
characteristics
overload Two times during 0.25 second in twenty times (100A) of rated current
characteristics (operating value and time : minimun tap)
Vibration In case of two times of vibration to each direction 4 front and left. above and below) in frequeney
characteristics 16.7hz. with 0.4mm in condition of 80% value of minimun seifty operating current. all part of relay should be good
Impacting
In case of impacting two times 30g weight to allparts. all parts of relay should be good
characteristics
Insulation resistor over 10MΪ by DC 500V Megger in condition of all circuit to cubicle, contact to contact. and circuit to circuit
AC 2000 1 minute common frequency in condition of all circuit to case. circuit to circuit
Dielectric voltage
AC 1000 1 minute common frequency in condition of contact to contact
Main Contact AC 220/10A
contact capacity AC 110/15A
Contacting time : 0.5 sec
For incoming
1 X5
TAP ≒ X 1.5
CT
순시전류정정
변압기의 도입여자전류로 오동작하지 않도록 변압기
용량에서 계산되는 전류치의 1,000~1,500%로 조정합니다.
1 X5
TAP ≒ X 10~16
CT
N
tN- × t10
10
Error= ×100(%)
● TRIP부 전류 증가방법 T10
계전기 동작(TRIP)시 ICS(동작표시기겸 보조접촉기)를 확실하게 동 T10 : Rating operating time
작 시키기 위해 ICS 정격의 2~3배의 전류가 흐를수 있도록 차단용 tN : measuring operating time of operating time lever(n)
AUX. RELAY 또는 52TC 의 임피던스를 적절히 조정할 필요가 있 N : Locating of operating time lever(tap)
습니다.
도 9-1과 같이 Coil과 병렬로 저항(R)을 접속하여 ICS에 흐르는 전
류를 조정합니다.
예) TC=1.5A DC110v의 경우 그림 9-1과 같이 Relay 2대가 동시
● How to increase current of trip coil
에 동작되는 사례도 발생됩니다. 따라서 저항 R값을 정격으로
Fig 9-1
사용하십시오.
110V
R= =27.5�25Ϊ, 100W
2A×2
110V
R= =27.5�25Ϊ, 100W
2A×2
DCG/DOG type
DCG/DOG형 지락과전류 계전기는 소세력 유도원판형으로서 주로 변류기 DCG/DOG type ground over current relay is induction rotary disk
의 잔류회로에 사용되며 지락 및 단락사고 보호용으로 사용된다. type that is operated in remained circuit current of current
transformer.
Specification
(fig 13)
DOV/DUV type
DOV, DUV형 전압계전기는 교류회로의 이상전압을 검출하여 송배전선과
기기의 손상을 방지하는 단상 유도 원판형 전압계전기입니다.
Features
Specification
Refer to characteristics wave of tested operating time(Fig14) Refer to characteristics wave of tested operating time(Fig15)
Self temperature At min tap Lever#1 The operating erro between The operating error will be ±5% of setting tap
rising normal condition and self temperature value
characteristics rising condition will be ±5% of setting tap value
1. operting value:Min TAP.Lever #1 1. operting value:Min TAP.Lever #1
-10℃, 50℃ Error ±10% -10℃, 50℃ Error ± 7%
2. operating time:MinTAP, Lever #10 2. operating time:MinTAP, Lever #10
Temperature
Input Operating time(SEC) Input Operating time(SEC)
characteristics
120% 26.6 ± 30% 80% 20.7 ± 30%
130% 17.7 ± 37% 0% 7.4 ± 15%
150% 9.84 ± 32%
DSG type
DSG형 방향지락 계전기는 비접지 계통의 고압배전 및 수전단의 지락 DSG type directional ground relay will be used for ground
보호용으로 사용되며 보호구간내에 cable과 대지간 충전전류가 클 경 fault protection of high voltage distribution and receiving line
우(예:cable이 길때) 에 적용됩니다. 모선(Main)에서 나와있는 다수의 in non-grounding system.
회선중 사고 회선만 선택 판별하여 차단시켜 정전사고 파급을 최소화 In case of discharging much current between cable and
할수 있습니다. earth in portection area, this relay will be applied. This relay
※ 접지 변압기 (GPT:3’ry 190 or 110V)및 영상 변류기 will select the fault line among many feeder lines of main bus
※ (ZCT:200/1.5mA) 조합하여 사용하십시오. and shut down the fault line. And then the fault will be
본 catalog 191page 참고 minimum
※ 본 계전기는 고감도형으로 배전반의 진동과 충격에 의해 오동작 �Ground transformer (GPT 3ry 190V or 110V) and zero phase
할 수 있습니다. 따라서 진동, 충격이 발생 할 수 있는 장소에서 current transformer(ZCT:200/1.5㎃)should be used for
는 DVG형 OVGR과 조합하여 사용하십시오. coordination.
�This relay may be misoperated by vibration and impact of
switchgear because it is very precious.
�In condition of being used in place of happening vibration
and impact, it should be used with over of DVG type.
Specification
�SGR
Rating
ICS Unit Weight
Type Model No Zero Phase Zero Phase Operating Current Burden
(DCA) (Kg)
Voltage(V) 1’
ry current
CD 1 110 34
Drawout DSG 150㎃ 0.5/2.0 4.5
CD 9 190 36
200(㎃)
Drawout C 1 110 Voltage:190V, Current:200㎃ 34
DSG 1.0 3.5
Non- C9 190 Phase angle:LEAD37。 36
Connection diagram
Connection diagram
Name of parts
How to drawout
A,B) release the cover handle of. E) take out the relay unit with drawout pin smoothly
C) Take over the dwawout pin located in each side of case. F) The relay unit will be seperated from the case
D) Take out drawout socket. ※ for assembling the relay, please reverse the process
Dimension
판넬용
지지전기계기(각형, 광각형)
Ordering procedure
Standard specification
Full Scale 1 1.2 1.3 1.4 1.5 2 2.4 2.5 3 3.8 4 4.5 4.8 5 6 5.2 7.5 8 9 31.2 1.6
Divisions 50 24 26 28 30 40 48 50 30 38 40 45 48 50 30 52 37.5 40 45 31.2 32
※ Actural full scale in the value of 10n times of table value.
※1 ※2 ※3
Full Scale 1 1.2 1.5 2 2.4 2.5 3 4 4.5 5 6 7 7.5 7.5 8 8 9
Divisions 20 24 30 20 24 25 30 20 22.5 25 30 35 37.5 15 40 16 45
※ Actural full scale in the value of 10n times of table value.
※ Remark ※1.2 in applicated for S8 type
※ Remark ※3 is applicated only for type S10
S7 type S4 type
Specification
※ 주문시 Hz 선택
특징 Features
1. Motor 회로에 사용시 기동전류를 감안하여 정격 전류치의 1. Select the 150~330% over scale meter of rating current
150~300%에 해당하는 초과눈금 계기를 사용하십시오. due to starting current of motor if it is used in motor circuit.
2. 선로전압(측정대상 전압)이 300V를 초과 할시는 계기용 PT를 조합 2. Combine the P.T for meter if the voltage of circuit
하여 사용하십시오. (Measuring voltafe) is over 300V
3. Panel 에 취부하기가 편리합니다. 3. It is very easy to install the meter on panel
■ S7형은“ㄷ” 형 Band를 이용 Nut로 조여 취부합니다. ■ In case of S7 type. it can be installed by ㄷ type band.
■ S4형은 판 Spring (SUS)이 부착되어 있어 CUT부위에 밀어 넣 ■ In case of S4 type. if can be installed easing by pushing
으면 간단히 취부됩니다. on the cut hole with plate spring (SUS)
Dimension
“W”type “S”type
Specification
특징 Characteristics
●AC Amperemeter ■ AC Amperemeter
1. 전류가 5A를 초과할 경우에는 정격 2차 전류가 5A(1A) 인 계기 1. Combine C.T of rating 2ry current 5A(1A) for meter if
current of case it in over 5A
용 변류기(C.T)를 조합하여 사용하십시오. 2. Combine P.T & C.T for meter in order to insulate the
2. 회로전압이 500V를 초과하고 전류가 5A 이하인 회로의 경우에 circuit if voltage of circuit over 500V and current of
circuit is below 5A.
도 확실한 절연을 위해 계기용 변류기를 조합하여 사용하십시오. 3. Select 150~500% over scale meter of rating current
3. 전동기 사용시 전류계의 Full Scale를 Motor의 기동전류를 감안 due to starting current of motor if it in for motor circuit.
하여 정격전류치의 150~500%에 해당하는 초과눈금 계기를 사 ■ DC Amperemeter
1. In case of below 30A current. the shunt installed in the
용하십시오. (초과 눈금의 오차는 ±10%입니다.) meter. But in case of over 30A current. the shunt in not
installed in the meter. please connect the shunt (50mA)
●DC Amperemeter outside.
1. 30A 이하인 전류에서는 자체 Meter에 분류기(Shunt)가 내장되 2. When you connect the shunt. connect the shunt on the
어 있어 필요없으나 30A 이상의 전류에서는 외부에 minus side.
Shunt(50mV)를 연결하여 사용하십시오.
2. Shunt 결선시 마이너스(-)측에 설치하십시오.
■ AC Ammeter ■ DC Ammeter
“W”type “S”type
Specification
Type Size Rating Freq(Hz) VA Class Weight(Kg)
W8-VA 150, 300V 50/60 0.5
80X80mm 1.0 or 1.5 0.33
W8-VD 150, 300V - 1KΩ/V
W11-VA 150, 300V 50/60 0.5
110X110mm 1.0 or 1.5 0.45
W11-VD 150, 300V - 1KΩ/V
S8-VA 150, 300V 50/60 5.0(0.5)
80X80mm 2.5 0.18
S8-VD 150, 300V - 1KΩ/V
S10-VA 150, 300V 50/60 5.0(0.5)
100X84mm 1.5 0.20
S10-VD 150, 300V - 1KΩ/V
※ VA: AC, VD: DC, W:Wide Angle Types, S: Square Type ※ The value of ( ) in for rectifier type ※ 주문시 Hz 선택
Characteristics
●AC Voltmeter ■ AC Meter
1. 입력전압이 AC 300V이상의 회로에는 150V전압계를 P.T와 조 1. Combine P.T with 150V meter if input voltage in over
합하여 사용하십시오.(600V 전압계는 주문에 의함) AC 300V circuit.
예) meter scale 0~9.000V. Input range 0~150V EX) meter scale 0~9000V. input range 0~150V
P.T ratio 6.600/110V P.T ratio 6.600/110V
●DC Voltmeter ■ DC Meter
1. 입력전압이 DC 750V 이상의 경우에는 외부 배율기를 부착 사용 1. Connect the multiplier outside in case of over DC 750V
하십시오. of input voltage.
2. 배율기는 (+)측에 결선 하십시오. 2. Connect the multiplier on pluse side.
3. DC Voltmeter의 전류감도는 1mA(1KΩ/V)입니다. 3. The current sensitivity of DC voltmeter in 1mA (1KΪ/V)
Ex) Choose of Meter
ex1) 3P 3W (In case of 6.6KV line) ex) 3P 4W (In case of 22.9KV line)
full scale value (V):9KV full scale value (V):31.2KV
P.T ratio:6.6KV/110V P.T ratio:22.9KV/110V
9KV 31.2KV
MAX. input range= =150V MAX. input range= =150V
6.6KV/110V 22.9KV/110V
■ DC Voltmeter ■ AC Voltmeter
“W”type “S”type
Specification
Characteristics
1. 정격을 초과하여 사용할 시에는 AC 110V, 5A 의 정격을 초과하여 1. Combine AC 110V P.T & AC 5A CT in case of over rating
사용시 PT, CT는 조합하여 사용하십시오. value.
2. 동작전압범위는 정격전압의 ±10% 이내입니다. 2. Allowance of operating voltage is ± 10% of rating voltage.
3. 최대 눈금은 위의 Standard Full Scale Table을 참조하여 사용하 3. For max scale. refer to the above Standard Full Scale
십시오. Table.
4. Watt Meter Transducer는 내부(INT.) 또는 외부(EXT.)형 2종류가 4. Watt Meter Transducer is internal type and external type.
있습니다. 5. In case of 3�4W voltage in phase voltage(Vι/ √ 3)
5. 3상 4선의 경우 상전압 (Vι /√
3 )으로 표시합니다. MAX. scale value
6. Calibrating Watt =
MAX. scale value PT ratio × CT ratio
6. 교 정 전 력 =
PT ratio × CT ratio
ex) 3P 3W ex1) 3P 4W
full scale wattmeter : 600KW full scale wattmeter : 2000KW
=
P.T ratio : 3300V/110V P.T ratio : 22900V 190V
C.T ratio : 100A/5A √
3 √
3
C.T ratio : 50A/5A
600KW 2000KW
calibrating watts = = 1.0KW calibrating watts = = 1.666KW
(3300/110)X(100/5) 22900V 190V
( √
3 √
3
) X (50/5A)
“W”type “S”type
Specification
example scale
Characteristics
1. 정격을 초과하여 사용할 시에는 AC 110V, 5A의 PT, CT를 조합하 1. Combine AC 110V P,T & AC 5A C.T in case of over rating
여 사용하십시오. value.
2. 동작전압범위는 정격전압의 ± 10% 이내입니다. 2. Allowance of operating voltage is ± 10% of rating voltage.
3. 최대 눈금은 위의 Standard Full scale Table 을 참조하여 사용하 3. For max scale. refer to the above standard full scale table.
십시오. 4. Var meter Transducer is internal type and external type.
4. Var meter Transducer는 내부(INT.) 또는 외부(EXT.)형 2종류가 5. In case of 3�4W. the voltage in phase voltage (Vι/√ 3 )
있습니다. 6. Select 1/2 or 1/3 or 1/4 value of total load capacity for max
5. 3상 4선의 경우 상전압( √ 3 )으로 표시합니다. scale.
6. 최대 눈금은 전부하용량의 1/2, 1/3, 1/4 로 선택하여 사용하십시오. MAX. scale value
7. Calibrating Watt =
MAX. scale value PT ratio × CT ratio
6. 교 정 전 력 =
PT ratio × CT ratio
ex) 3P 3W ex1) 3P 4W
full scale varmeter : 300KVar full scale Var meter : 1000KVar
P.T ratio : 3300V/110V P.T ratio : 22900V 190V
C.T ratio : 100A/5A √3 √3
C.T ratio : 50A/5A
300KVar 1000KVar
calibrating Var = = 0.5KVar calibrating Var = = 0.833KVar
(3300/110)X(100/5) 22900V 190V
( √ 3 √3
) X (50/5A)
“W”type “S”type
Specification
1. 정격을 초과하여 사용할 시에는 AC 110V, 5A의 PT, CT를 조합하 1. Combine AC 110V. PT & AC 5A C.T in case of over rating
여 사용하십시오. value
2. 동작전압범위는 정격전압의 ±10%이내입니다. 2. Allowance of operating voltage is ± 10% of rating voltage.
3. Power Factor meter, Transducer는 내부(INT.) 외부 (EXT.) 형 3. Power Factor meter. Transducer can be classified 2type
2종류가 있고 Balance형과 Unblance형으로 구분합니다. (internal and external) and it can be classified 2 type
4. 3상 4선의 경우 상전압(Vι /√ 3 )으로 표시합니다. (Balance and unbalance)
5. 2차 정격전류 5A의 10%인 소부하의 경우는 역률의 정상지시를 기 4. In case of 3�4W, voltage is phase voltage (Vι /√ 3)
대할수 없으며 정격전류의 1/3 이상이 되어야 정확한 오차가 보증 5. On over 1/3 value of rating current. it is certified the error
됩니다. correctly because it is not expected normal indication of
6. 역률계의 Standard scale의 LEAD 0.5~1.0 ~ 0.5 LAG입니다. power factor in case of 10% load of rating 2ry current 5A.
6. The standard scale of power factor meter is Lead
0.5~1.0~0.5 lag
“W”type “S”type
Specification
Characteristics
1. 주파수의 Standard full scale은 45Hz~55Hz, 55Hz~65Hz 2종 1. Standard full scale of frequency meter in 2 types :
류가 있습니다. 45HZ~55HZ and 55HZ~65HZ
2. 정격전압을 초과할 경우는 외부 P.T를 조합하여 사용하십시오. 2. Combine P.T in outside in case of over the rating voltage.
3. 동작전압의 범위는 AC 110V: 80~120V, AC220V: 160~240V입 3. Allowance of operating voltage in 80~120V for AC 110V
니다. and 160~240V for AC 220V
4. 주파수 METER의 Pointer는 Needle type입니다. 4. Pointer of power factor meter in needle type.
Feature
The Vo meter is a electronic type for demand Vo. which is
displayed by 3 digit FND window on the lower part of the
meter with mechanical type indicatior for real time Vo value.
Comparing with mechanical type. the Electronic Vo meter no
slip error against inertia moment of indicating needle set.
적용 Application
이 Vo메타는 1선 지락시 접지 전류량이 작아 전류요소로 접지 상태를 The Vo meter is application for detecting zero sequence
파악 할 수 없는 장소에 전원측 PT의 2차측을 Open-Delta 결선하여 voltage on the distribution line which has small ground
이 메타에 연결, 사용합니다. current. As soon as one phase is grounded by fault. zero
phase sequence voltage is generated, For the purpose, the
meter would be connected with Open-Delta circuit of 3 phase
PT secondary.
사용법 Description
1. 아래의 결선도에서와 같이 결선합니다. 1. To connect a meter as shown below
2. 외장형 재충전용 밧데리를 메터에 연결합니다. 2. To connect the meter with external rechargeable battery
3. To enerzise source PT
3. 3상 전원을 살립니다.
4. The wide range analog indicator will indicate real time Vo
4. 선로에 영상 전압이 발생하면 광각형 지시계기에 현재의 영상 전압 voltage. If any on the line. The indicating value will move
을 지시합니다. 이 값은 현재의 값이므로 선로의 상태 변경에 따라 according to real time line situation,
변합니다. 5. The demand value on the Display with 3 digit FND located
5. 영상 전압의 크기가 최대값이 되면 그 값은 3digit Display에 나타 lower part of the front plate of the meter, is shown a fixed
나며 EPROM에 저장 됩니다. 최대값이 되면 갱신 될 때 마다 peak vaule. The value is stored in a EEPROM in the meter.
Whenever new peak vaule is generated, the vaule is
Display 값은 상향 지시 합니다.
renewed instead of the old data.
6. 표시된 최대치는 Display 오른 쪽에 있는 Reset Button 을 누르면 6. The Display is errassed by pressing reset button on the
영구히 지워 집니다. right side of the Display.
7. 영상전압이 10V 미만에서는 최대치를 표시하지 않습니다. 7. Demand display is designed to be indicated to be
indicated for higher than 10Volt.
사양
Item Model Rating Full Scall Accuracy Aux.Power Freq. Burden Weight
(AC) (%) (AC) (Hz) (VA) (Kg)
Vo Meter W11 DVA 110/190 150/259 1.5 at FS 110V/190V 60 0.5 1.0
Feature
The Ao meter is a electronic type for demand Ao. which is
displayed by 3digit FND window on the lower part of the
meter with mechanical type indicatior for real time Ao value.
Comparing with mechanical type, the Electronic Ao meter no
slip error against inertia moment of indicating needle set.
적용 Application
이 Io메타는 계통사고 또는 비정상시 발생하는 영상전류를 측정하는 The lo meter is applied for detecting zero sequence current
메타로, 직접 접지 또는 저항접지 계통에 적용하며 ZCT 또는 3 CT의 on the distribution live which is ground solidly or with
중성선에 연결하여 사용합니다. resistance. As soon as one phase is grounded by fault. zero
phase sequence current is generated. For the purpose. the
meter would be connected with a ZCT or neutral line of 3 CT
connection.
사용법 Description
1. 아래의 결선도에서와 같이 결선 합니다. 1. To connect a meter as shown below.
2. 외장형 재충전용 밧데리를 메터에 연결합니다. 2. To Connect the meter with external rechargeable battery
3. To be flow unbalanced current at the relay terminal as the
3. 3상 전원을 투입시킵니다. below diagram.
4. 선로에 영상 전류가 발생하면 광각형 지시계기에 현재의 영상 전류 4. The wide range analog indicator will indicate real time lo
를 지시합니다. 이 값은 현재의 값이므로 선로의 상태 변화에 따라 current. The indicating value will move according to real
항상 변합니다. time unbalanced line current.
5. The demand value on the Display with 3 digit FND located
5. 영상 전류의 크기가 최대값이 되면 그 값은 3 Digit Display에 타
lower part of the front plate of the meter, is shown a fixed
나나며 EEPROM에 저장 됩니다. 최대값이 되면 갱신 될 때 마다 peak value. The value is stored in a EEPROM in the meter.
Display 값은 갱신된 값을 지시합니다. Whenever new peak value is generated. the value is
6. 표시된 최대치는 Display 오른쪽에 있는 Reset Button을 누르면 renewed instead of the old data.
6. The Display is errassed by pressing reset button on the
영구히 지워집니다.
right side of the Display.
사양
Item Model Rating Full Scall Accuracy Aux.Power Freq. Burden Weight
(A) (A) (%) (AC) (Hz) (VA) (Kg)
Ao Meter W11 DAA 1 or 5 1 or 5 1.5 at FS 110V/190V 60 0.5 1.0
※주문시 ㎐ 선택
Dimension
UNIT : m/m
Dimension
UNIT : m/m
특징 Model
Specification
Wiring
Dimension
General Specification
Insulation Temperature
� Insulation resistance at DC500V 100MΪ � Operating temperature : 0~ 50℃
� Withstand voltage 2KV for 1 minuts between all terminals � Storage temperature : -20 ~ +70℃
� Lightning impulse voltage 1.2/50μ
s 4.5kV
Example of Application
Front view
Ordering Code
D
Digital Meter D : Direct(직가) 01 : Ampere-(19.99A,199.99A, 1999A중 선택)
A : analog(입력) 02 : Volt-AC0~500V(500V이상의 경우는 보조 PT사용)
9:W96mmXH48mm 03 : DC 1㎃~10A(F.S지정)
04 : DC 50㎃~350V(F.S지정)
AA : AC Ammeter(A) 05 : DC 4~20㎃(With TD-F.S는 주문에 의함)
AV : AC Voltmeter(V) 06 : DC 4~20㎃(With TD-F.S는 Program 방식)
DA : DC Ammeter(A)
DV : DC Voltmeter(V)
WT : Watt(W)
VR : var(var)
PF : PowerFactor(cosφ)
HZ : Frequency(㎐)
(50,60㎐선정)
WH : kWhr meter
VH : kVarh meter
AC Ammeter
Ordering Procedure
AC Voltmeter
Ordering Procedure
Ordering Procedure
DC Voltmeter
Ordering Procedure
Ordering Procedure
P.F의 극성 표시는“-”
만 표시됩니다.
Ordering Procedure
Ordering Procedure
Wiring
Ampere Volt
●DR CT 1차 도체 관통회수에 따른 전류비와 1차도체 단면적 ●Current ratio and across area of 1ry conductor
다음 표는 정격 1차 전류와 1차 도체 관통회수 및 관통가능한 600V According to turn of DR. CT 1ry conductor Follwing table
비닐 전선(600V Ⅳ 전선)의 최대공칭 단면적을 기재하였습니다. is discribed the trun rating 1ry current, 1ry conductor and
이 표의 값은 주위온도 40℃에서 전선의 허용 전류를 표시하였습니다. the cross area of 600V vinyl wire(6000.I Wire)
The allownace current of wire is the value at amboent
temperaure 40℃ discribed.
Unit : mm
Primary Dimension
Primary Dimension Type
Type current(A) A B C D E F G H(∅)
curreent A B D
40~150 80 100 60 125 100 25 3.2 6
(20~75)
DRW-15 80 100 90 DRB-1 200~300
5~30 80 100 60 135 105 30 6 10
DRBD-1 (100~150)
DRW-40 100 118 102 400~500
(200~250) 80 100 60 155 115 30 6 12
40~150
(20~75) 100 118 70 135 110 25 3.2 6
DRB-2 200~300
100 118 70 145 115 30 6 10
DRBD-2 (100~150)
400~500
(200~250) 100 118 70 165 130 40 6 12
Dimension
Type
A B C D
DS-1, DSD-1 44 110 80 10
DS-2, DSD-2 65 115 65 11
DS-3, DSD-3 85 135 70 13
DS-4, DSD-4 105 155 85 22
DS-5, DSD-5 130 212 126 41
DS-6, DSD-6 160 260 180 75
DS CT is designed how to install the busbar is very
easy being used the installing metal. Busbar.
●Specification
DP-50
50 2.5
DP-50F
220
DP-100 110
1.2Vn
V.T 380 or 100 3.2
cont
DP-100F 190
440
DP-200
- - 200 5.8
DP-200F
DGP-100
1.0 50 50/60 3.2
※ 주의 : 3차 권선의 open terminal 간의 부담이 DGP-100F
정격 부단보다 많이 작게되면 잔류전압이
발생되어 계전기의 오동작 원인이 될 수도 DGP-200
있습니다. 220 3 190/ 3 100 5.8
사용부담을 정격 부담의 100~70%가 되도록하여 주 DGP-200F 1.2Vn
시기 바랍니다.
GPT 380 3 or cont
※ Note : It the burden of 3ry winding open DGP-100T 100
terinal is less than rating burden. 1.9Vn
190/3 50 3.2
It may be the reason of relay 440 3 110/ 3 30s
DGP-100TF 3.0C
malfunction due to remaining
or 3P
voltage. DGP-200T 200
Please select the pit that applieable burden
of PT will be 100~70% of rating burden. 110/3 100 5.8
DGP-200TF 3.0C
●Dimension
Model A B C D E
DP-50 100 102 30 75 77
DP-100/DGP-100 118 112 33 75 73
DP-200/DGP-200 166 126 37 82 142
∙Color : Brown
∙Resin : Lupoy Non-flamable (case)
∙Mold : Epoxy
Specification
Type Specificaton
Standard KS C-1706
Max. Voltage 3.45kV/7.2KV
Rated Burden 15, 40VA
Accuracy Class 1.0/10P10
Frequency 50/60HZ
Rating
Model Primary(A) Secondary(A) Class(%) Burden(VA) Over Current Over curr.strength Weight(kg)
AHB-1 1.0 40 -
5~300 5 40 times 4.0
AHB-1R ※ 1.0/10P10 15 n〉
10
Dimension
Model Primary(A) A B C D E F
AHB-1
5~300 187 100 110 35 66 4
AHB-1R ※
∙Color : Brown
∙Resin : Lupoy Non-flamable(case)
∙Mold : Epoxy
Unit: mm
Model A B C D E
AHS-1/AHSD-1 146 145 92.5 10 65
AHS-2/AHSD-2 186 155 97.5 20 105
Type Specificaton
Standard KS C-1706
Max. Voltage 3.45kV/7.2KV
Rated Burden 15, 40VA
Accuracy Class 1.0/10P10
Frequency 50/60HZ
Model 1ry current(A) 2ry current(A) Class(%) Burden(VA) Over Current consrant Over curr.strength Weight(kg)
AHS-1 300~600 40 -
5 or 1 1.0
AHS-2 750~2000 40 -
40 times 5.0
※
AHS-1R 400~600 15 n〉
10
5 or 1 1.0/10P10
AHS-2R ※ 750~2000 15 n〉
10
*R: For Protective Relay
Model 1ry current(A) 2ry current(A) Class(%) Burden(VA) Over Current consrant Over curr.strength Weight(kg)
400~600
AHSD-1 1.0 40 - 5.0
200~300
800~2000 5 or 1
AHSD-2 1.0 40 - 5.0
400~1000
400~600 40 times
AHSD-1R※ 1.0/10P10 15 n〉
10, n〉
5 5.0
200~300
800~2000 5 or 1
AHSD-2R※ 1.0/10P10 15 n〉
10, n〉
5 5.0
400~1000
∙Color : Brown
∙Resin : Lupoy Non-flamable (case)
∙Mold : Epoxy
Type A B C D E F
AHP-1 125 160 223 107 55 87
AHP-2
138 160 223 107 55 98
AHP-3
Specification
Type Specificaton
Standard KS C-1706
Max. Voltage 3.45kV/7.2kV
PRI. Voltage 3,300 or 6,600V
Accuracy Class 1.0/ 3.0
Frequency 50/60HZ
Secondary Voltage 110V
Rating(Single ratio)
∙Color : Brown
∙Resin : Lupoy Non-flamable (case)
∙Mold : Epoxy
Type A B C D E F
AHGP-2 125 160 223 107 55 87
AHGP-3 138 160 223 107 55 98
Specification
Type Specificaton
Standard KS C-1706
Max. Voltage 3.45kV/7.2KV
PRI. Voltage 3,300/ 6,600V
Accuracy Class 1.0/3G
Frequency 50/60HZ
Secondary, third Voltage 110/3. 190/3
Rating(Single ratio)
Class(%) Burden(VA)
Model 1ry Voltage(V) 2ry Voltage(V) 3ry Voltage(V) Weight(kg)
2ry 3ry 2ry 3ry
3300/√3 or 190/√3 190/ 3
AHGP-2 1.0 3G 50 100 8
6600/√3 110/√3 110/ 3
3300/√3 or 190/√3 190/ 3
AHGP-3 1.0 3G 100 200 10
6600/√3 110/√3 110/ 3
※ 주의 : 3차 권선의 open단자간의 사용부담이 정격 부담보다 작게되면 잔류전압이 발생되어 계전기의 오동작 원이이 될 수도 있습니다.
사용부담을 정격부담의 100~70%가 되도록하여 주시기 바랍니다.
※ Note : It the burden of 3ry winding open terminal is less than rating burden. It may be the reason of realy malfunction due to remaining voltage
please select the pit applieable burden of P.T will be 100~70% of rating burden.
DEESYS TOTAL PRODUCTS GUIDE 239
Round Type Zero Phase Sequence Current Transformer [3.45-7.2kV]
Dimension
Type A B C D
ZT-1 177 70 175 95
ZT-2 220 110 220 120
Specification
Type Specificaton
Standard KS C-1706
Rated Impedance 10Ω(P.F : 0.5LAG)
Accuracy Class “L”CLASS
Frequency 50/60HZ
Rating(Single ratio)
Model Rated current(A) Zero phase 1ry(mA) Zero phase 2ry(mA) error(mA) burden(Ω)
ZT-1 5~300 200 1.5 1.5 (1.0-2.0) 10(PF : 0.5LAG)
ZT-2 400~1200 200 1.5 1.5 (1.0-2.0) 10(PF : 0.5LAG)
unit: mm
30
2-M6 DP7
Rating
∙분전반, 배전반 제어반 등의 절연을 위하여 사용되는 EPOXY 수지로 된 절연지지 애자로 저압회로에 사용됩니다.
unit: mm
2-M10 DP14
Rating
∙분전반, 배전반 제어반 등의 절연을 위하여 사용되는 EPOXY 수지로 된 절연지지 애자로 고압회로에 사용됩니다.
∙전기적, 기계적 내구성이 우수합니다.
unit: mm
Rating
∙분전반, 배전반 제어반 등의 절연을 위하여 사용되는 EPOXY 수지로 된 절연지지 애자로 고압회로에 사용됩니다.
∙전기적, 기계적 내구성이 우수합니다.
unit: mm
LGD-9075 LGD-9085
Rating
∙분전반, 배전반 제어반 등의 절연을 위하여 사용되는 EPOXY 수지로 된 절연지지 애자로 고압회로에 사용됩니다.
∙전기적, 기계적 내구성이 우수합니다.
unit: mm
※액상
Rating
∙분전반, 배전반 제어반 등의 절연을 위하여 사용되는 EPOXY 수지로 된 절연지지 애자로 특고압회로에 사용됩니다.
∙전기적, 기계적 내구성이 우수합니다.
unit: mm
Rating
∙분전반, 배전반 제어반 등의 절연을 위하여 사용되는 EPOXY 수지로 된 절연지지 애자로 고압회로에 사용됩니다.
∙전기적, 기계적 내구성이 우수합니다.
unit: mm
LGD-280100 LGD-310115
Rating
Dimension
Division A B C D E F H Type
Rating(DC A)
10~100 130 26 75 103 150 17 13 DST-1
120~200 139 30 75 103 160 24 17 DST-2
220~300 139 30 75 103 160 24 17 DST-3
● DST-4~7(400~750A) ● DST-10~30(1000~3000A)
Dimension
TYPE DST-4 DST-5 DST-6 DST-7 DST-10 DST-12 DST-15 DST-20 DST-25 DST-30
Rating(DC A) 400 500 600 750 1000 1200 1500 2000 2500 3000
Division
A 40 50 50 60 70 80 90 100 100 100
● DST-40(4000A) ● DST-50(5000A)
한류저항은 GPT 3차측, a, f간에 접속되어 사고시 1차측 중성선에 흐르는 전류(lg)를 조정하여
(통상 380mA) 유효 전류를 발생시켜 지락계전기 및 영상전압계를 동직시킵니다. 또한 GPT 3차
측(OPEN DELTA)에 발생하는 제3고조파 및 이상전위 발생을 억제시켜 줍니다.
Current limit resistor(CLR) will make the grounding relay and zero voltage meter
operate due to the current which in a djusted primary neutral side current when
fault. And it will be connected with 3ry side of GPT between terminal “a” and
terminal “f” and then it restrains the 3ry harm once voltage and abnormal potential.
Specification
※ Remark : 1. If max 3ry voltage of GPT is on CLR during 1 minute over, the 6.600V 1 9
R= × × = 25(Ω)
CLR may be fired. √3 602 0.38
2. In case og low voltage G.P.T. Please adjust the value of CLR
to 100~70% loading value of rating burden on GPT 3ry open Ig : Ground Fault Current
terminal. E1 : GPT 1ry voltage
n : Voltage Ratio = Winding Ratio
※ 비고 : 1. GPT의 최고전압이 1분이상 인가되면 CLR이 소손될 우려가 있습니다. R : Limting Resister(Ϊ )
2. 저압 GPT인 경우 3차 정격부담의 70~100%가 되도록 CLR 저항값을 조정
해서 사용하시기 바랍니다.
Dimension
Unit : mm