Buidling System Design

You might also like

Download as txt, pdf, or txt
Download as txt, pdf, or txt
You are on page 1of 2

A.

MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE FOLLOWING


BUILDING CODES: AC1-318-83 AND NSCP - 2015 ED.
B. IN THE INTERPRETAITONS OF THESE DRAWING. INDICATED DIMENSIONS OR SIZES SHALL NOT
BE SCALED FOR CONSTRUCTION PURPOSES, UNLESS OTHERWISE NOTED. ALL DIMENSIONS ARE TO
ROUGH CONCRETE SURFACES.
C. MINIMUM CONCRETE PROTECTION OF REINFORMCING BARS SHALL BE 0.075 METER CLEAR FOR
CONCRETE DEPOSITED AGAINSE THE GROUND, AND 0.05 METER CLEAR FOR CONCRETE DEPOSITED
AGAINST THE FORMWORK.
D. BACKFILL SHALL BE PLACED IN LAYERS NOT EXCEEDONG 0.15M OR AT FLOOR LINE METERS
IN DEPTH. EACH LAYER MUST BE MOISTENED AS DIRECTED AND DIRECTLY COMPACTED BEFORE
PLACING THE NEXT LAYER.

FOUNDATION
A.ALL FOOTING ARE DESIGNED BASED ON THE ALLOWABLE SOIL BEARING CAPACITY OF 150 KPA.
IF MARKED DIFFERENCE IS OBTAINED OR ENCOUNTERED DURING CONSTRUCTION, THE STRUCTURAL
ENGINEER SHOULD BE INFORMED SO THAT APPROPRIATE CHANGES CAN BE MADE.

CONCRETE
DESIGN WORKING STRESSES FOR CONCRETE ARE BASED ON THE FOLLOWING TWENTY EIGHT(28)
DAYS ULTIMATE COMPRESSIVE STRENGTH.
CAST-IN-PLACE SLABS, CONVENTIONAL BEAMS,COLUMNS,WALLS, STAIRS FOOTING UNLESS
OTHERWISE SPECIFIED.

SLAB ON FILL
f'c = 21.0 MPa
Vc = 17.5 MPa

REIFORCEMENT
ALL MILD REINFORCEMENTS SHALL BE NEW BULLET STEEL
PS GRADE 415 - 25MM 0 BAR TO 16 0 BAR
PS GRADE 275-12MM 0 BAR TO 10MM O BAR

CONCRETE BEAMS
A. UNLESS OTHERWISE NOTED IN THE PLANS, CAMBER ALL REINFORCED CONCRETE BEAM AND
GILDERS ATA LEAST 6MM FOR EVERY 4.00 METERS OF SPAN EXCEPT CANTILEVERS WHICH SHALL
BE 18MM FOR EVERY 3.00 METERS OF SPAN.
B. IF THERE ARE TWO(2) LAYERS OF REINFORCING BARS, USE 25MM DIA. SEPARATORS SPACED
AT 1.00 M O.C
C. IF BEAM REINFORCING BAR END IN THE WALL, THE CLEAR DISTANCE FROM THE BAR TO THE
FARTHER FACE OF THE WALL SHALL NOT BE LESS THAN 5X OF DIAMETER THE REINFORCING BAR
SHALL TERMIANTE ON A STANDARD 90 DEGREES HOOK.
D. WHEN BEAM CROSSES A GILDER, REST BEAM BARS ON TOP OF GILDER BARS.
E. LENGTH OF CUT-OFFS AND CLEARANCES SHALL BE AS SHOWN UNLESS OTHERWISE INDICATED
ON PLANS.

CONSTRUCTION COLUMNS
1. CONSTRUCTION JOINTS IN COLUMNS SHALL BE LOCATED AT THE TOP OF THE PEDESTRAL OR
FOOTING AT MID- HEIGHT OF COLUMN.
2. ALL TIES SHALL BE FASTENED TO COLUMN VERICAL REINFORCEMENT BY MEANS OF WIRES AT
INTERSECTION POINTS OF TIES AND COLUMN REBARS.
3. NOT MORE THAN ONE-HALF (1/2) OF TOTAL NUMBER OF BARS SHALL BE SPLICED AT THE
SAME LEVEL.
4. LEAP WELDED SPLICES MAY BE USED. THE CAPACITY OF THE WELD PROVIED SHALL BE 125%
LARGER THAN THE TENSILE CAPACITY OF BIGGER BARS BEING SPLICED ARE ALLOWED UNLESS
OTHERWISE PERMITTED BY THE STRUCTURAL ENGINEER.

CONCRETE WALLS
A. UNLESS OTHERWISE INDICATED IN THE PLAN. THE R.C. WALL HORIZONTAL BARS SHALL
ENCLOSE THE VERTICAL BARS.
B. REINFORCING BARS SHALL BE 0.03M CLEAR FROM THE FACE OF THE WALL EXCEPT IN 0.1M
WALL WHERE THEY SHALL BE AT THE CENTER.
C. CARRY VERICAL BARS,0.60M ABOVE FLOOR LEVEL TO PROVIDE FOR SPLCIES WHEN NECESSARY
ELSEWHERE STOP AT 0.05M BELOW THE TOP OF THE SLAB.
D. HORIZONTAL AND VERTICAL BARS, IF NECESSARY SHALL BE SPLICED BY LAPPING A
DISTANCE EQUAL TO 24 0 AND WIRED SECURELY WITH #16 G.I WIRE PROVIDED THAT SPLICES
IN ADJACENT BARS ARE STAGGERED AT LEAST 1.50 METERS ON CENTERS.

CONSTRUCTION JOINTS
A. CONSTRUCTION JOINTS SHALL BE NEAR THE MIDDLE OF SPAN, BEAM OR GILDERS
INTERSECTION, THE CONSTRUCTION JOINTS ON THE GIRDER SHALL BE OFFSET A DISTANCE
EQUAL TO TWICE THE WIDTH OF THE BEAM DIAGONAL BARS SHALL BE PROVIDED TO RESIST 100%
SHEAR AT THE CONSTRUCTION JOINTS.
B. WHERE JOINTS ARE TO BE MADE, THE SURFACE OF CONCRETE SHALL BE THOROUGHLY CLEANED
AND ALL LAITANCE AND STANDING WATER REMOVED. VERTICAL JOINTS SHALL BE THROUGHLY
WETTED AND COATED WITH NEAT CEMENT. GROUT IMMEDIATELY BEFORE PLACING A NEW
CONCRETE.
C. TYPICAL DETAILS OF SLAB AND BEAM CONSTRUCTION JOINTS SHALL BE SHOWN.

STRUCTURAL STEEL
A. STRUCTUAL FRAME SHALL BE A36 STRUCTURAL STEE (fy - 250 MPa)
B. SHOP DRAWINGS OF ALL STRUCTURAL STEEL SHALL BE SUBMITTED TO THE STRUCTURAL
ENGINEER FOR THE APPROVAL PRIOR TO FABRICATION AND ERECTION.

CONCRETE SLABS
A. IF SLABS ARE REINFORCED BOTH WAYS, THE SHORT SPAN BOTTOM BARS SHALL BE PLACED
BELOW LONG SPAN AND TOP BARS, VICE VERSA
B. LENGTH OF BAR CUT-OFFS SHALL BE SHOWN.

REMOVAL OF FORMS
STRIPPING OF FORMS SHALL BE AS FOLLOWS
1. FOUNDATION - DAYS
2. COLUMNS - 3 DAYS
3. BEAMS AND GILDERS - 21 DAYS
4. BEARINGS AND RETAINING WALLS - 3 DAYS
5. SLABS - 12 DAYS
6. CANTILEVER BEAMS AND SLABS - 28 DYAS

ABBREVIATIONS
F - FOOTING
C - COLUMNS
GB - GRADE BEAM
B - BEAM
S - SLAB

3484 - ce 3211, 3485 - ce 3211D, 3486- ce 3221,3487- ce 3221D, 3488- ce 3231, 3489-
ce 3231L, 3492-ce 4111, 3447 - cfe 106A

As an instalock player, i acknowledge the fact that my teammates have to pick


around my instalock. Therefore i have to tell y'all that i will not 1. Complain
about my team. 2. Complain about bottom fragging teammates. 3. Try my very hardest
with this team. Dedicate the next 30+ minutes of my life to my team and my
teammates only. I'll PROMISE YOU i will be trying my HARDEST! And I hope it goes
both ways. Also, I would be lying to you if i promise to topfrag, but i can promise
i'll try my hardest

You might also like