XR DETAIL

TYPICAL END DETAIL


OF R.C.C WALL.
TYPICAL SLAB OR BEAM
CONSTRUCTION JOINT

DETAIL AROUND OPENINGS


IN R.C.C WALLS OR SLABS.
SECTION 1 TYPICAL CONSTRUCTION JOINT
TYP. DETAIL OF SOLID SUNK SLABS BETWEEN WALL & FOUNDATION
TYPICAL WALL CONSTRUCTION JOINT

TYP.DETAIL OF WATER PROOFING


TYPICAL DETAILS FOR WALLS OPENING SECTION-A AT RETAINING WALL & PILE CAPS

TYP. SEPTIC TANK SLAB PLAN

SECTION-A
TYP. BEAM SECTION. TYP. ARCH DETAIL /
EXTRA CONC. DETAIL.

TYP. DETAIL OF BLOCK WORK


BELOW TIE BEAM TYP. TOP OF COLUMN DETAIL

A/C VENTILATION & PIPE TYP. A/C BASE DETAIL


SHAFT DETAIL (ROOF)
TYP. SOLID SLAB REINF. IN PLAN
TYP. DETAIL OF FOOTINGS

SCHEDULE OF LINTELS

TYP. SLEEVE THROUGH CONC. BEAM


(NOT TYP. FOR JOIST) TYP. R.C.C WALL INTERSECTION TYP. R.C.C WALL CORNER

TYP. DETAIL OF CONT. SOLID SLABS

TYP. DETAIL OF REINF. FOR SIMPLY SUPPORTED


TYP. DETAIL OF CONTINUOUS BEAM
SOLID SLAB RESTING ON BEAM OR WALL
SECTION B

SPIRAL STAIR PLAN

SECTIONAL ELEVATION

TYPICAL THREAD

SPIRAL STAIR PLAN

ELEVATION SECTION A
FOUNDATION
TYPICAL DETAIL OF CAT LADDER
5600 1800 1847 1800 5400 100

100
3800
1800

STAIRCASE DETAIL
4200
1500

COLUMN DETAILS
6450

C1
2050

C2
1500
700

C3

COLUMN AXIS LAYOUT


(SCALE-1:150)

C4
5600 1800 1847 1800 5400 100

100
3800
1800
4200
1500
6450
2050
1500
700

REVISED

COLUMN AXIS LAYOUT


(SCALE-1:150)
5600 1800 1847 1800 5400 100

100
3800
1800
4200
1500
6450
2050
1500
700

REVISED

COLUMN AXIS LAYOUT


(SCALE-1:150)
3900
SECTION A-A
SCALE 1:50
700 1500 2050 6450 1500 4200 1800 3800 100 5600
1800
1847
1800
5400
100
5600 1800 1847 1800 5400 100

100
+0.65 m.
+0.65 m. S.S.L.
S.S.L. +0.65 m.

3800
S.S.L.
+0.65 m.
S.S.L.

1800

+0.65 m.
S.S.L.
4200

+0.65 m.
S.S.L.

STAIRCASE DETAIL
1500

+0.65 m.
+0.65 m. S.S.L.
S.S.L.
6450

+0.65 m.
S.S.L.

+0.65 m.
2050

S.S.L. +0.65 m.
S.S.L.
1500
700

PC

TIE BEAM LAYOUT


(SCALE-1:150)
5600 1800 1847 1800 5400 100

100
3800
1800

+14.45m.
S.S.L.
4200

+14.15m.
S.S.L.
1500
6450
2050
1500
700

UPPER ROOF SLAB LAYOUT


(SCALE-1:100)
(AT +2.424m. LVL.)

(AT +3.803m. LVL.)


+2.424m.
LANDING S.L

1600

1600

1600
C C C C
- 1550 2150 1550 - - -
2150 1550

1750

4000
1750

2050
2100

2100
1750

1750
425 900 425 425 900 425

100

300
600

+0.65m. +5.05m.
1750 F.F.L S.S.L
HALL

4 4

GROUND FLOOR PLAN FIRST FLOOR PLAN


STAIR CASE DETAIL - VILLA (Scale: 1:50) STAIR CASE DETAIL - VILLA (Scale: 1:50)
+3.870m
+4.120m +3.730m N.G.L.
N.G.L. N.G.L.

+3.600m
N.G.L.

+3.610m
N.G.L.
SECTION - 1

+3.790m
N.G.L.

+3.680m
N.G.L.

CONTRACTOR HAS TO CONFIRM W/AUTHORITY


01 02 +3.610m FOR FINAL GATE LEVEL PRIOR TO START ANY
+3.550m N.G.L. CONSTRUCTION ACTIVITY
N.G.L.

+3.520m
N.G.L.

+3.640m * NO EXCAVATION ALLOWED BENEATH ANY NEIGHBORING FOUNDATION


* IN CASE A DIFFERENCE IN LEVEL IS ENCOUNTERED BEYOND 1.2 METER
N.G.L. +3.500m
+3.550m THE CONSULTANT HAS TO SUBMIT A RETAINING WALL DESIGN FOR APPROVAL
N.G.L. N.G.L. * FORMATION LEVEL OF BOUNDARY WALL, FOUNDATION SHALL BE AT A MINIMUM
OF -1.0 METER BELOW NATURAL GROUND LEVEL

SECTION - 2