NOTES:-

1. ALL DIMENSIONS ARE IN MM (U.N.O).


2. GRADE OF CONCRETE SHALL BE M20.
3. HYSD BARS CONFORMING TO IS:1786 (GRADE Fe500) / TMT BARS.
4. LAP LENGTH SHALL BE 50 TIMES BAR DIA AND LAPS SHALL BE
STAGGERED.
5. LAP SPLICES SHALL NOT BE PROVIDED.
a). WITHIN JOINT.
b). WITHIN A DISTANCE OF 2d FROM JOINT FACE.
c). CLOSE TO SUPPORT FOR TOP BARS AND CLOSE TO MID SECTION
FOR BOTTOM BARS.
6. CONCRETE CLEAR COVER TO MAIN RFT. SHALL BE AS FOLLOWS :-
COLUMNS = 40MM ALL SIDES.
FOOTING = 50MM AT BOTTOM & SIDES.
BEAMS = 25MM AT TOP, BOTTOM & SIDES.
BEDROOM O4 SLAB = 20 MM AT TOP & BOTTOM.
PUJA
7. THIS DRAWING SHALL BE READ ALONG WITH THE ARCHITECTURAL
AND OTHER RELATED DRAWINGS.
BALCONY
8. THIS DRAWING SHALL NOT BE SCALED OFF.
9. CLEAR COVER TO REINFORCEMENT NEAREST TO THE FACE OF A

LOW HEIGHT CABINET


MEMBER SHOULD BE AS FOLLOWS :-
EXISTING (a) LONGITUDINAL BAR IN BEAM : 25MM
WELL (b) SLAB: NOT LESS THAN 15MM
TOILET 925 [3'] (c) FOR A LONGITUDINAL REINFORCING BAR IN A COLUMN:40MM
SKYLIGHT
(d) FOOTINGS : NOT LESS THAN 50MM
10. ALL BENT UP BARS SHALL BE BENT AT 45 AND AT L/4 FROM
DRESS
CONTINUOUS EDGES AND T L/7 FROM CENTER OF SIMPLY SUPPORTED
EDGES.
DRESS 11. ALL BENT UP BARS OVER CONTINUOUS SUPPORTS IN BEAMS SHALL
ROAD FOYER
BE EXTENDED BY L/4 OR Ld ( WHICHEVER IS GREATER ) IN TO ADJOINING
TOILET SPAN. ( WHERE Ld IS DEVELOPMENT LENGTH OF THE PARTICULAR BAR.)
12. ALL BENT UP BARS OVER CONTINUOUS SUPPORTS IN SLABS SHALL
TV UNIT BE EXTENDED BY L/3 OR Ld ( WHICHEVER IS GREATER) INTO THE ADJOINING
DINING TABLE SPAN.
13. TOP REINFORCEMENT OF ALL CANTILEVER BEAMS , SLABS AND
DRESS DRESS CROOKED BEAMS SHALL BE TAKEN BY Ld INTO THE COLUMNS OR INTO THE
THIS DOCUMENT IS THE PROPERTY OF KRIBAL ASSOCIATES. ANY IMITATION/REPRODUCTION OF THIS IS NOT PERMITTED WITHOUT PRIOR WRITTEN CONSENT FROM THE OWNER OF THE DOCUMENT.

BALCONY ADJOINING BEAMS OR SLABS. EXTRA TOP SHALL BE PROVIDED FOR


BEDROOM O3 CANTILEVER PART.
STORE 14. NO CONCRETE WORK SHALL COMMENCE TILL ALL REINFORCEMENT
BEDROOM O1 BEDROOM 02
DETAILS ARE APPROVED BY US AND CHECKED BY THE SITE ENGINEER-IN
CHARGE APPOINTED BY THE OWNER.
15. ONLY ORDINARY PORTLAND CEMENT ( O.P.C ) OF 43 GRADE /53
GRADE OF APPROVED MAKE SHALL BE USED FOR R.C.C WORK.
KITCHEN 16. DISCREPANCIES, IF ANY SHALL BE BROUGHT TO THE NOTICE OF THE
STRUCTURAL CONSULTANT BEFORE COMMENCING THE WORK.
17. ALL MATERIALS USED FOR CONCRETING WORK, i.e., FINE AGGREGATE
TOILET TOILET
( SAND )COARSE AGGREGATE AND WATER SHALL CONFORM WITH LATEST I.
RF S. CODE OF PRACTICE.
18. DE-SHUTTERING :-
(a) WALLS , COLUMNS AND VERTICAL FACES OF ALL STRUCTURAL
MEMBERS: 24 TO 28 HOURS AS MAY BE DECIDED BY THE ENGINEER - IN -
CHARGE
(b) SLABS ( PROPS LEFT UNDER ) : 3 DAYS

GF PLAN (c)
(d)
BEAMS SOFFITS ( PROPS LEFT UNDER ) : 7 DAYS
REMOVAL OF PROPS UNDER SLABS;
1, SPANNING UP TO 4.5 M : 7 DAYS
2, SPANNING OVER 4.5 M : 14 DAYS
(e) REMOVAL OF PROPS UNDER BEAMS AND ARCHES;
1, SPANNING UP TO 6 M : 14 DAYS
2, SPANNING OVER 6 M : 21 DAYS

BEDROOM O7
BALCONY

01 03/08/2022 SECOND ISSUE AD

00 27/07/2022 FIRST ISSUE AD

TOILET 925 [3']


REV. DATE BY
DESCRIPTION
SKYLIGHT

DRESS
PROJECT:-
PASSAGE
DRESS G+1 RESIDENTIAL AT SEONI. RAIPUR

TOILET

ARCHITECT:-
DRESS DRESS YND STUDIO
BALCONY
BEDROOM O6
BEDROOM O5 OPEN TERRACE

TV UNIT
LIVING AREA

STORE ROOM

TOILET TOILET KRIBAL ASSOCIATES


STRUCTURAL CONSULTANT
428, GOLDEN TRADE CENTRE
NEW RAJENDRA NAGAR
FF PLAN RAIPUR (C.G)
PH: 9713711228
N
DRAWING TITLE COLUMN W E

DWG NO. 02
LAYOUT-ARCHITECTURE S

DRAWN BY GANESH THORAT NTS DATE 27/07/2022


DESIGNED & ABHINAV DAGA REV. NO. 01 SHEET NO. 01
CHECKED BY

You might also like