SP Folder Fap Eng

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

SP

SP Battery Range

FIAMM.COM
T HE S P R A N G E I S D E S I G N E D T O S AT I S F Y A W I D E
R A N G E O F A P P L I C AT I O N S R E Q U I R I N G H I G H L E V E L O F
MAIN APPLICATIONS:

S E C U R I T Y A N D R E L I A B I L I T Y.

SP BATTERIES OFFER GOOD PERFORMANCE WITH ANY


DISCHARGE PROFILE. SP BLOCS CAN BE INSTALLED IN
CABINETS OR RACKS. SP USES PROVEN VRLA TECHNOLOGY SECURITY SYSTEMS AND
WITH 99% INTERNAL RECOMBINATION EFFICIENCY, IS EMERGENCY LIGHTING
NON-SPILLABLE AND MAINTENANCE FREE THEREFORE
REQUIRES NO TOPPING UP OF ELECTROLYTE DURING ITS
FLOAT-LIFE. SP RANGE IS NON-HAZARDOUS FOR AIR/SEA/
RAIL/ROAD TRANSPORTATION AND IS 100% RECYCLABLE.
SP HAS A SELF-DISCHARGE RATE LESS THAN 2% PER
MONTH, GUARANTEEING LONG SHELF-LIFE.

RE NE WABLE E NE RGY

LI GHT T RACT I ON

LE I SU RE

SPECIFICATIONS
Special lead calcium tin alloy grid, designed to resist corrosion and provide short recharge time

VRLA AGM technology using low resistance high microporous fiberglass separators

Leak resistant post seal, threaded female M5/M6/M8 terminals with high conductivity and maximum torque resistance

One-way safety relief valves allow gas to escape and prevent the ingress of oxygen.
Flame arrestors prevent sparks or flames entering the battery

ABS flame retardant (V0 grade) designed for superior mechanical strength

Heat sealed box to lid weld for superior integrity

Installation in any orientation (excluding permanently inverted)


TECHNOLOGY

Terminal Pillar Internal Strap

Separators
Negative Flat Plate

The image is for illustrative purposes only.

F I A M M S P R A N G E U S E A G M ( A B S O R B E D G L A S S M AT ) T E C H N O L O G Y. T H E E L E C T R O LY T E I S
A B S O R B E D I N F I B E R G L A S S S E PA R AT O R S W I T H 9 9 % I N T E R N A L G A S R E C O M B I N AT I O N E F F I C I E N C Y.
BLOCS ARE GRANTS NON-SPILLABLE AND MAINTENANCE FREE THEREFORE REQUIRES NO
T O P P I N G U P O F E L E C T R O LY T E D U R I N G I T S W H O L E L I F E . L O W S E L F - D I S C H A R G E A L L O W S
6 MONTHS SHELF LIFE.

CAPACITY SHORT CIRCUIT INTERNAL


NOMINAL NOMINAL DIMENSIONS (mm) TYPICAL
BATTERY (Ah) CURRENT RESISTANCE TERMINAL
VOLTAGE WEIGHT
TYPE TYPE
(V) 20 hrs to 1.75 VPC (kg)
at 20°C
IEC 60896-21-22 IEC 60896 21-22 Length Width Height Tot. Height

12SP26 12 26 630 19.5 166 175 125 125 9.0 Female M6

12SP33 12 33 925 13.5 196 130 159 164 11.5 Female M6

12SP42 12 42 1332 9.4 197 165 170 170 13.5 Female M6

12SP55 12 55 1400 8.9 229 138 207 212 18.2 Female M6

12SP70 12 70 2688 4.6 272 166 191 195 22.4 Female M8

12SP72 12 70 1530 8.5 350 166 175 175 22.6 Female M8

12SP80 12 80 2333 5.3 259 168 209 213 25.3 Female M8

12SP100 12 100 2479 5.1 329 172 214 221 32.0 Female M8

12SP120 12 120 2858 4.5 407 173 220 225 37.7 Female M8

12SP135 12 135 2920 4.3 345 172 276 281 46.3 Female M8

12SP150 12 150 3002 4.2 483 170 220 220 44.6 Female M8

12SP210 12 205 4100 3.0 522 238 219 224 61.5 Female M8

12SP240 12 240 4300 2.8 520 269 203 208 71.0 Female M8

ELECTRICAL CHARACTERISTICS STANDARDS


Float Voltage: 2.26 V/cell at 25°C IEC 60896 Part 21 - VRLA methods of testing
Boost Voltage: 2.40 V/cell IEC 60896 Part 22 - VRLA requirements
Float Voltage Compensation with Temperature: -2.5 mV/cell/°C Eurobat “10-12 years LONG LIFE”
Self-Discharge at 25°C: <2%/month UL Recognized

FIAMM Energy Techology reserves the right to change or revise without notice any information or detail given in this publication SP Battery Range_2019_03
CERTIFICATIONS
ISO 9001
Quality Management System

ISO 14001
Environmental Management System

OHSAS 18001
Workplace Safety & Health

DISCHARGE CURVES at different current / final voltage (at 25°C)

2.2

2.1
Battery Voltage (V/cell)

2.0

1.9

1.8
0.10 C

1.7 0.37 C
0.50 C
1.0 C
1.6 1.5 C

1.5
1 10 100 1.000 10.000
Discharge time (min)
The above discharge curves are typical. For more detailed information please see the specific product sheets.

TYPICAL CHARGE CURVES STORAGE


Battery Voltage and Charge Time for Standby Use (at 25°C) Capacity loss during storage at various temperatures

[A] [V/Cell] [%]


2.4 140 100
Charging Current

Charging Voltage

The battery can be


2.2 120 used without
refreshing charge

Remaining Capacity (%)


2.0 100 90
Recharged Capacity

Refreshing charge at
2.4 Vpc for 24 hours
1.8 80 (at 20-25°C) must be
applied as soon as
possible
1.6 60 80
0.10 C10 5°C
Refreshing charge of
40 2.4 Vpc may be
insufficient to recover 20°C
0.05 C10 the battery capacity. 30°C
40°C
20 It is important to 70
avoid this area <80%

0 0 0
0 5 10 15 20 [hours] 0 2 4 6 8 10 12
Storage Time (months)
Voltage 100% Recharged 100% Current 100%
50% Capacity 50% 50%

FIAMM Asia Pacific PTE LTD infostandby.asia@fiamm.com


3B Toh Guan Road East #01-00 www.fiamm.com
608833 Singapore - Republic of Singapore
Tel. +65 68676150
Fax +65 68626550

A Hitachi Group Company youtube.com/user/FIAMMvideo

You might also like