BENEFITS
BENEFITS
Current Table
Daikin RA-Product Energy Efficiency Upgradation & Energy
Saving Trend 2010~2024
1.5 TR-5 Star
Lowest APC 667.36
Units /Year 1600
7 Efficiency Trend Daikin RA Product 35%
Hrs
6.2
1.5 TR Lowest 5.8 30%
6
APC 1118.58 60 % More
5 25%
5 Units /Year 1600 Energy
4.5
Hrs 29% 24% 20% Efficient
3.8
4
3.3
3.6 3.5 3.6 3.5 Products Vs
3.1 3.15 15%
2012-2013
3 9%
3% 10%
2% 9%
2
5%
1 0%
0 -5%
2010-11 2012-13 2014-2015 2016-2017 2018-22 2022-2024
5 Star EER/ISEER 5 Star -Daikin %
YEAR 2010-11 2012-13 2014-2015 2016-2017 2018-22 2022-2024
5-Star EER/ISEER as per
Min BEE Requirement 3.1 3.3 3.5 3.5 4.5 5
5 Star -Daikin 3.15 3.6 3.6 3.8 5.8 6.2
% 2% 9% 3% 9% 29% 24%
Global Cooling Prize Award (GCP)
Daikin Entry
Holistic approach that look at equipment lifecycle to optimize efficiency and
low environment impact
• Multi split (Connect 2 IDU to 1 ODU): Optimize refrigerant flow via
refrigerant control technology to precisely modulate the IDU Capacity.
Achieved
• Evaporative cooling method: Implement control technology to automate
ISEER-7.20
water spray under the high ambient condition. Heat of vaporization shall in GCP
be used to lower the temperature of ODU intake air. ISEER
• Low GWP HFO-1234ze(E) has been proposed for this system. 44% 7.20
Higher
ISEER
Award Ceremony:
Daikin & Nikken Sekki won the GCP Prize on 29th April 2021 ISEER
5
TECHNOLOGCALLY
DAIKIN HERITAGE COMFORT HEALTH SAFETY SMART LOOKS
SUPERIOR
Swing compressor is a
modified advance type of
Rotary Compressor:
It saves electricity for lower
pressure return during compression
Conventional Inv AC
Widest Range
Daikin 6Hz 10Hz 15Hz 20Hz 50Hz 75Hz 100Hz 110Hz 120Hz 150Hz
o 5 in 1 Cooling
Daikin’s Variable
Benefit
o
o
Expandable AC
Convertible AC = Speed Inverter
AC (Automatic)
o Adjustable AC
• Faster Cooling
C-1 frequency range -- 12~150 Hz
• Fully Automatic no Manual operation C-2 Frequency range-- 6~130 Hz
• Optimum Cooling & Maximum User Comfort Patented Swing Compressor
Critical Components & Refrigerants which contributes in energy efficiency
Daikin Patented Swing Compressor Technology which ensures less noise, Daikin uses rare earth magnet “Neodymium Magnet” which is 10 times
less wear and tear and above all high energy efficiency. stronger than Ferrite Magnet what others using,
1. Larger surface area and hence better heat Stator part Heat transfer coil:
transfer Distributed roll
Current New
2. Oscillatory movement, of refrigerant increasing
its travel time in the pipe
3. Making the AC design sturdy for increased
durability
4. Achieving High ISEER or COP for better heat Concentrated roll
dissipation
Distributed roll The heat loss is
5. Installing more number of ACs in the same space
because of smaller foot print Concentrated roll reduced
Unique Technology & Feature Ensures consistent performance
SENSING TECHNOLOGY
Dual sensors and individual airflow direction control automatically provide optimal control of airflow.
The temperature near the person is automatically calculated by detecting the temperature of the floor and
presence of people.
Benefits
Reduce Wastage of Cooling and
Energy Saving.
Approx. Approx.
Moisture removal Vs
840ml/h 50ml/h
Benefits
Better Cleaning of Heat Exchanger ensures better airflow
throughout the year. Benefits
Airflow remains the same even after a long duration of use. Reduce Wastage of Cooling and Energy Saving
Consistence performance of Air conditioners
Unique Technology & Feature Ensures consistent performance
Benefits
Reduce Wastage of Cooling and Energy Saving
Uninterrupted Sleep during sleeping time
Benefits As per BEE every 1°C Temperature setting will ensure
Ensure check & Tracking of Estimated Power approx. 6% Of Energy Saving
Consumption in %
Ensure Monitoring of AC uses based on inside and
ambient load condition.
X'tensive Range : VRV Outdoor Unit
VRV X (Top Discharge) VRV S (Side Discharge)
Higher capacity up to 60 HP, enhancing its suitability for
Large-Sized Buildings
33.92*
According to a survey by
Daikin (based on Air
Conditioning Network
Service System Data)
Integrated Energy Efficiency Ratio (IEER)
addresses the actual efficiency of HVAC
equipment that operates at different load
levels.
This ratio accounts for both full load and part
load efficiencies.
• Utilizing new technologies, Daikin’s VRV X series enhance energy efficiency during low loads.
X'tra Power Savings
Energy Saving VRT Smart Control Software Technology
Cooling Operation:
Evaporating temperature (Te) ↑
(Energy Saving)
X'tra Power Savings
Energy Saving VRT Smart Control Software Technology
VRT smart control also controls the airflow rate of indoor units
automatically*, to attain detailed energy-saving control.
* Airflow rate should be set to “Auto ”.
X'tra Power Savings
New Scroll Compressor
Conventional
• Movable scroll is pressed New intermediate pressure
by the pressure difference mechanism
between high and low Force pressing the movable
pressures. scroll is optimized according
• The force pressing the to the operating conditions.
movable scroll decreases Behavior of movable scroll
during low-load operation, has been stabilized to
resulting in compression increase efficiency during
leakage from movable low-load operation.
parts.
Refrigerant leakage is
minimized during low-load
operation :
Operation loss due to
refrigerant leakage is reduced
by the proprietary back
pressure control mechanism
to ensure stable low-load
operation.
X'tra Power Savings
Inverter Compressor : Motor ODU DC Fan Motor
Low RPM Motor DC ODU Fan motor with 9 steps automatic control
50% stronger magnetic force & higher rotation efficiency of Allows fine rotation control, reducing energy consumption &
rotor improving the Operational efficiency by 40% compared to AC
motor at lower speeds as shown in graph below.
Reluctance DC Motor for Compressor Neodymium Magnets • Allows fine rotation control, reducing
• Energy saving by generating more power with a energy consumption.
10 times stronger than
smaller electric current than conventional standard ferrite magnets & • Operational efficiency improved by 40%
motors. enhances the compressor compared to AC motor which are
• Neodymium magnet generates strong magnetic performance noticeable at lower speeds.
field & high torque resulting on high efficiency.
• Approximately 20% improvement in frequency
at low frequencies
Ferrite Neodymium
Magnet Magnet
Design Flexibility
VRV air cooled air conditioning system is VRV water cooled system is designed to exchange heat
designed to exchange heat recovered from recovered from indoors with water from the cooling tower.
indoors with outdoor air. Additional cooling tower need to be installed.
VRV IDU's with Sensing Panel
Presence of people & floor temperature can be detected to provide comfort & energy savings
Off Timer
• Turns off the air conditioner after a preset period of time.
• Period can be preset from 30 to 180 minutes in 10-minute
increments.
Energy Savings : Centralized Control System
Precise energy management through REIRI
Improve operational cost & On-the-go
Easy access, monitor & control the VRV and connected devices anytime, from
efficiency, while reducing the
anywhere with Reiri Mobile App
management cost
Prevent unnecessary energy waste
Turn on & off all HVAC & connected devices when necessary
Flagship Model
ReiriOffice
Touch ReiriOffice ReiriOffice Multi-site ReiriOffice Plus
DCPF04
DCPF01 DCPF10 DCPF05
With successful launch of Star Labelling program in which RAMA collaborated with BEE in developing and implementation of
the program and the upgrades in tables subsequently. RAMA advocates to look at alternatives for energy efficiency/saving to
meet the NDC goals. One such initiative which is implemented is adoption 24 Degree Centigrade as default temperature. Apart
from reduction in energy consumptions through new equipment, RAMA is proposing to BEE to develop replacement policy for
old inefficient ACs that are 10 years plus old. This will have multiple benefits to all the stake holders