Super-Efficient AC’s & Its features

3rd August, 2022

Gaurav Mehtani - Daikin


Room AC and Lcom Range
BEE Regulation Journey : Star Rating Update
CURRENT BEE STAR RATING ISEER TABLE Now SHIFT TO NEW ISEER TABLE w.e.f 1st July-2022
The objective of a BEE’s Standards & Labeling Program is to provide the consumer an informed choice about the energy saving
and thereby, the cost saving of appliances.
In order to meet the consumer requirement, BEE (Bureau of Energy Efficiency) keeps on improving the labeling standards. Initially,
they changed and merged the rating methodology for Inverter & Fixed Speed air conditioners by introducing ISEER (Indian
Seasonal Energy Efficiency Ratio) in 2018 and now, changed the ISEER TABLE w.e.f 1st July 2022 as given in next slide.

BENEFITS

Benefits of Star Labelling


 Star rating schemes allow us to compare the operating cost and
environmental performance of similar products.
 This allows us to make better choices and see the potential ongoing
future costs and greenhouse gas impacts our decisions may have.
 Energy labels, on the other hand, are the informative labels affixed to
manufactured products in order to provide consumers with the data
necessary for making informed purchases.
BEE Regulation Journey : Star Rating Update
CURRENT BEE STAR RATING ISEER TABLE Now SHIFT TO NEW ISEER TABLE w.e.f 1st July-2022
The objective of a BEE’s Standards & Labeling Program is to provide the consumer an informed choice about the energy saving
and thereby, the cost saving of appliances.
In order to meet the consumer requirement, BEE (Bureau of Energy Efficiency) keeps on improving the labeling standards. Initially,
they changed and merged the rating methodology for Inverter & Fixed Speed air conditioners by introducing ISEER (Indian
Seasonal Energy Efficiency Ratio) in 2018 and now, changed the ISEER TABLE w.e.f 1st July 2022 as given in next slide.

BENEFITS

Benefits of Star Labelling


 Star rating schemes allow us to compare the operating cost and
environmental performance of similar products.
 This allows us to make better choices and see the potential ongoing
future costs and greenhouse gas impacts our decisions may have.
 Energy labels, on the other hand, are the informative labels affixed to
manufactured products in order to provide consumers with the data
necessary for making informed purchases.
BEE Regulation : Star Rating Update 2009~2024
2009-2011 2014-2015 1st January-2018 to 30th June -2022

2016-2017 1st July-2022 to 31st December 2024


2012-2013

Daikin’s all Star Rated


Products has 24 Deg
Default temperature
Setting

Current Table
Daikin RA-Product Energy Efficiency Upgradation & Energy
Saving Trend 2010~2024
1.5 TR-5 Star
Lowest APC 667.36
Units /Year 1600
7 Efficiency Trend Daikin RA Product 35%
Hrs
6.2
1.5 TR Lowest 5.8 30%
6
APC 1118.58 60 % More
5 25%
5 Units /Year 1600 Energy
4.5
Hrs 29% 24% 20% Efficient
3.8
4
3.3
3.6 3.5 3.6 3.5 Products Vs
3.1 3.15 15%
2012-2013
3 9%
3% 10%
2% 9%
2
5%

1 0%

0 -5%
2010-11 2012-13 2014-2015 2016-2017 2018-22 2022-2024
5 Star EER/ISEER 5 Star -Daikin %
YEAR 2010-11 2012-13 2014-2015 2016-2017 2018-22 2022-2024
5-Star EER/ISEER as per
Min BEE Requirement 3.1 3.3 3.5 3.5 4.5 5
5 Star -Daikin 3.15 3.6 3.6 3.8 5.8 6.2
% 2% 9% 3% 9% 29% 24%
Global Cooling Prize Award (GCP)
Daikin Entry
Holistic approach that look at equipment lifecycle to optimize efficiency and
low environment impact
• Multi split (Connect 2 IDU to 1 ODU): Optimize refrigerant flow via
refrigerant control technology to precisely modulate the IDU Capacity.
Achieved
• Evaporative cooling method: Implement control technology to automate
ISEER-7.20
water spray under the high ambient condition. Heat of vaporization shall in GCP
be used to lower the temperature of ODU intake air. ISEER
• Low GWP HFO-1234ze(E) has been proposed for this system. 44% 7.20
Higher
ISEER
Award Ceremony:
Daikin & Nikken Sekki won the GCP Prize on 29th April 2021 ISEER
5

ISEER-5 Min-5 Star as per BEE till Dec-2024

Energy Saving Co2 emission reduction of cost saving


Technologically Superior & ‘Value for Money’ Product

TECHNOLOGCALLY
DAIKIN HERITAGE COMFORT HEALTH SAFETY SMART LOOKS
SUPERIOR

•Patented Swing •World’s Leading Air •COANDA Airflow


•Patented Streamer •Stabilizer Inside •Elegant & pleasing double
Compressor Technology Conditioning Company from •Smell proof operation
•Reluctance DC motor Japan •Good sleep OFF timer discharge technology •Stabilizer Free louvers
•Variable Speed Inverter •ON/OFF timer
AC(Fully Automatic) •97 Years of customers trust •Eco friendly Refrigerant R- •Super PCB •Triple Display
•Temperature Display
•Dew Clean Technology •True-Feel 32 •Slim & Compact IDU & ODU
•Power supply at ODU
•Highest ISEER & High •Innovators - Leader in •Power Chill
Ambient Working Inverter technology - Energy •Advance PM 1 & PM 2.5 •Anti -Corrosion Treatment •Matte & Glossy finish
•Longer Air throw
•Intelligent Eye saving and Comfort; R – 32;
•Quiet Operation filters •Curved & edge designs
•Automatic Error Code VRV •Quality Control Order (QCO)
•Econo Mode
•Wi-Fi Enabled smart AC •Anti Microbial Filter
•Higher Moisture Removal
with voice command
•Backlit Operation •TAD Filter
•Inner grooved Copper
Condenser & Evaporator •3-D Air Flow
•Winner of Global Cooling
Prize

o Daikin is world’s leading Air-conditioning Company from Japan


o An Air-conditioning specialist, Daikin is the only air-conditioning company in the world which makes its own Air Conditioners ,compressors
and own refrigerant R-32
Unique Technology which contributes in energy efficiency
Patented Swing Compressor

Energy-savings with improvement in compression efficiency

Swing compressor is a
modified advance type of
Rotary Compressor:
 It saves electricity for lower
pressure return during compression

 Quiet and efficient for low friction


and vibration (better than rotary
compressor)
Adopted cylinder structure - less liable to heat
 Patented by Daikin - no other AC
transfer loss and deformation during operation manufacturer can use the same
Variable Speed Inverter AC (Automatic)
Daikin Inverter is true inverter AC, Daikin DC inverter models are equipped with the reluctance DC motor for compressor. The reluctance DC motor uses two different types of
torque, neodymium magnet and reluctance torque. This motor saves energy by generating more power with a smaller electric current than AC or conventional DC motors.
Swing Compressor Technology have Variable Speed automatic compressors with wider rotational frequency range, these wide frequency range ensures faster cooling and more
efficiency. It constantly adjusts the compressor’s speed to maintain desired levels of temperature and assured energy savings – both power and electricity bills.

Swing bush Refrigerant


Piston

Conventional Inv AC
Widest Range
Daikin 6Hz 10Hz 15Hz 20Hz 50Hz 75Hz 100Hz 110Hz 120Hz 150Hz

o 5 in 1 Cooling
Daikin’s Variable

Benefit
o
o
Expandable AC
Convertible AC = Speed Inverter
AC (Automatic)
o Adjustable AC
• Faster Cooling
C-1 frequency range -- 12~150 Hz
• Fully Automatic no Manual operation C-2 Frequency range-- 6~130 Hz
• Optimum Cooling & Maximum User Comfort Patented Swing Compressor
Critical Components & Refrigerants which contributes in energy efficiency

1 Swing Compressor 3 Neodymium Magnet

Daikin Patented Swing Compressor Technology which ensures less noise, Daikin uses rare earth magnet “Neodymium Magnet” which is 10 times
less wear and tear and above all high energy efficiency. stronger than Ferrite Magnet what others using,

2 Super PCB 4 R-32 Advantage

Daikin patented R-32 Refrigerant which is a single refrigerant


gives Daikin machines a unique edge over others- Refrigeration Cycle
 R-32 is Environment-Friendly(Zero ODP)
700 Volt  1/3RD Global Warming Potential
 75% less carbon dioxide emissions R410A Capacity
R32 Capacity (1.6 times)
 Better Life cycle climate performance
 15.3% more cooling as compared to R410A
Super PCB design to ensure safety of  30% refrigerant charging volume as compared to R410A &
the electrical parts and smooth R22
inverter operation leads to energy  5% more power savings compared to R-410A
saving too .  Better Performance at higher temperature a
Critical Components enhances Energy Efficiency
5 Inner grooved copper pipe 6 IDU & ODU DC Motor -improvement in Motor Efficiency

Daikin uses inner grooved copper pipe in condenser & evaporator


Reluctance DC Motor
Plain copper pipe Inner Grooved copper pipe
Rotor part Neodymium
Current New magnet: Changed
to 6 pieces from
earlier 4 pieces -
Rotation of motor
gets more
smooth.
Inner grooved copper pipe helps in: Neodymium magnet

1. Larger surface area and hence better heat Stator part Heat transfer coil:
transfer Distributed roll
Current New
2. Oscillatory movement, of refrigerant increasing
its travel time in the pipe
3. Making the AC design sturdy for increased
durability
4. Achieving High ISEER or COP for better heat Concentrated roll
dissipation
Distributed roll The heat loss is
5. Installing more number of ACs in the same space
because of smaller foot print Concentrated roll reduced
Unique Technology & Feature Ensures consistent performance
SENSING TECHNOLOGY

Dual sensors and individual airflow direction control automatically provide optimal control of airflow.
The temperature near the person is automatically calculated by detecting the temperature of the floor and
presence of people.

Benefits
 Reduce Wastage of Cooling and
Energy Saving.

 Over Cooling can be prevented

 Saves Energy based on the location of


people and floor temperature.

 flaps are controlled to deliver optimal


airflow when the room is unoccupied
 The system automatically saves
energy by detecting whether or not the
room is occupied
Unique Technology & Feature Ensures consistent performance

Dew Clean Technology Intelligent Eye –an Energy Saving feature

Approx. Approx.
Moisture removal Vs
840ml/h 50ml/h
Benefits
 Better Cleaning of Heat Exchanger ensures better airflow
throughout the year. Benefits
 Airflow remains the same even after a long duration of use.  Reduce Wastage of Cooling and Energy Saving
 Consistence performance of Air conditioners
Unique Technology & Feature Ensures consistent performance

Triple Display Function Good Sleep Off Timer-Saves Energy


Complete monitoring & control in the hands of consumer

Benefits
 Reduce Wastage of Cooling and Energy Saving
 Uninterrupted Sleep during sleeping time
Benefits  As per BEE every 1°C Temperature setting will ensure
 Ensure check & Tracking of Estimated Power approx. 6% Of Energy Saving
Consumption in %
 Ensure Monitoring of AC uses based on inside and
ambient load condition.
X'tensive Range : VRV Outdoor Unit
VRV X (Top Discharge) VRV S (Side Discharge)
Higher capacity up to 60 HP, enhancing its suitability for
Large-Sized Buildings

• 8 Base Models to get different Capacity Combination


• Available with 2 HP incremental capacity to suit various
requirement
• Both Cooling Only / Heat Pump series available

4, 5HP- 1Ø 6HP- 1Ø, 8HP- 3Ø 10/12HP - 3Ø


Dimensions Dimensions Dimensions
(HxWxD) : 990 (HxWxD) : 870 x (HxWxD) : 1627
x 940 x 320 1100 x 460 x 940 x 460

Cool Only & Heat Pump Series


X'tra Power Savings
Increased Efficiency during low load operation
• Key to innovative energy savings is to increase efficiency during low-load operation.
• Using data gathered from actual operation, Daikin discovered that air conditioning systems
operate at a load factor of 50% or less for 70% of their annual operation period.
IEER
up to

33.92*
According to a survey by
Daikin (based on Air
Conditioning Network
Service System Data)
Integrated Energy Efficiency Ratio (IEER)
addresses the actual efficiency of HVAC
equipment that operates at different load
levels.
This ratio accounts for both full load and part
load efficiencies.

IEER = (0.020 x A) + (0.617 x B) + (0.238 x C) + (0.125 x D)


A = EER@100%, B = EER@75%,
C = EER@50%, D = EER@25%

* Varies from model to model

• Utilizing new technologies, Daikin’s VRV X series enhance energy efficiency during low loads.
X'tra Power Savings
Energy Saving VRT Smart Control Software Technology

VRT adjusts refrigerant temperature according


to individual building & climate requirement, thus VAV (variable air volume) controls the
further improving the annual energy efficiency airflow rate of indoor units automatically,
while maintaining comfort conditions. to attain detailed energy-saving control.

VRT + VAV = VRT Smart


X'tra Power Savings
Variable Refrigerant Temperature
VRT automatically adjusts refrigerant temperature to individual building and climate requirement.

Cooling Operation:
Evaporating temperature (Te) ↑

Less Compressor Work

(Energy Saving)
X'tra Power Savings
Energy Saving VRT Smart Control Software Technology

Overview of VRT Smart


Control (system control flow)

Different automatic energy-saving


refrigerant control is applied
depending on the connected indoor
units.

VRT smart control also controls the airflow rate of indoor units
automatically*, to attain detailed energy-saving control.
* Airflow rate should be set to “Auto ”.
X'tra Power Savings
New Scroll Compressor
Conventional
• Movable scroll is pressed New intermediate pressure
by the pressure difference mechanism
between high and low Force pressing the movable
pressures. scroll is optimized according
• The force pressing the to the operating conditions.
movable scroll decreases Behavior of movable scroll
during low-load operation, has been stabilized to
resulting in compression increase efficiency during
leakage from movable low-load operation.
parts.
Refrigerant leakage is
minimized during low-load
operation :
Operation loss due to
refrigerant leakage is reduced
by the proprietary back
pressure control mechanism
to ensure stable low-load
operation.
X'tra Power Savings
Inverter Compressor : Motor ODU DC Fan Motor
Low RPM Motor DC ODU Fan motor with 9 steps automatic control
50% stronger magnetic force & higher rotation efficiency of Allows fine rotation control, reducing energy consumption &
rotor improving the Operational efficiency by 40% compared to AC
motor at lower speeds as shown in graph below.

4-pole Motor 6-pole Motor

1480 RPM 960 RPM

2% higher efficiency in part load condition!


Design Flexibility
Flexibility to connect Type Capacity Range
Ceiling Mounted Cassette (Compact Multi Flow) 0.8 ~ 2.0 HP
• multiple type of indoor units which opens the door to stylish,
quiet units matching the interiors. Ceiling Mounted Cassette (Round Flow) 1.0 ~ 6.0 HP
• multiple IDU’s up to 64 units with a single Outdoor Unit. Ceiling Mounted Cassette (Round Flow
1.0 ~ 5.0 HP
w/Sensing Panel)
• Area treatment equipment (OAPU, HRV) can be connected
Ceiling Mounted Cassette (Double Flow) 0.8 ~ 6.0 HP
• PM2.5 filtration available in various type of IDU’s
Ceiling Mounted Cassette Corner 1.25 ~ 2.5 HP
Slim Ceiling Mounted Duct 0.8 ~ 2.5 HP
Ceiling Mounted Duct 0.8 ~ 10.0 HP
Ceiling Mounted Duct (Mid static) 1.6 ~ 4.0 HP
Clean Room AC 1.6 ~ 2.5 HP
Wall Mounted 0.8 ~ 2.5 HP
Ceiling Suspended 1.25 ~ 5.6 HP
Floor Standing 0.8 ~ 2.5 HP
Concealed Floor Standing 0.8 ~ 2.5 HP
Floor Standing Duct 5.0 ~ 20.0 HP
Design Flexibility
Connection Ratio
X'tra Power Savings
Highly Efficient Swing / Scroll Compressors DC Fan Motor

Reluctance DC Motor for Compressor Neodymium Magnets • Allows fine rotation control, reducing
• Energy saving by generating more power with a energy consumption.
10 times stronger than
smaller electric current than conventional standard ferrite magnets & • Operational efficiency improved by 40%
motors. enhances the compressor compared to AC motor which are
• Neodymium magnet generates strong magnetic performance noticeable at lower speeds.
field & high torque resulting on high efficiency.
• Approximately 20% improvement in frequency
at low frequencies

Ferrite Neodymium
Magnet Magnet
Design Flexibility

Offers broad design flexibility with


• long refrigerant piping lengths and
• Multiple indoor unit combinations,
which provides generous freedom for office and shop
design both inside and outside.

As many as 19 indoor units can be connected to a


single outdoor unit.

VRV S provides the long piping length possibility of


150 m, with a total piping length of 300 m.
VRV Water Cooled
Individual air conditioning system that utilizes water as a heat source
VRV IV W Line Up
6 ~ 12 HP 14 ~ 24 HP 26 ~ 36 HP
VRV Air Cooled vs Water Cooled
VRV Air Cooled (VRV X / VRV S) VRV Water Cooled (VRV W IV)

VRV air cooled air conditioning system is VRV water cooled system is designed to exchange heat
designed to exchange heat recovered from recovered from indoors with water from the cooling tower.
indoors with outdoor air. Additional cooling tower need to be installed.
VRV IDU's with Sensing Panel
Presence of people & floor temperature can be detected to provide comfort & energy savings

• Sensing sensor low mode : Set


temperature is shifted automatically if the
room is unoccupied leading to energy savings.
• Sensing sensor stop mode : When there
are no people in a room, the system stops
automatically & saves energy
• Floor temperature is detected and over
cooling prevented : Temp. near the person
is automatically calculated by detecting the
temperature of the floor. Energy is saved,
because area around the feet doesn’t get too
cold.
• Auto Airflow Function
• Comfort to the entire room with even
temperatures and no cold air pockets at
floor level
Energy Savings : Individual Control System
Set Point Range Set
• Saves energy by limiting the min. and max. set temperature.
• Avoids excessive cooling or heating.
• Function is convenient when the remote controller is installed at
a place where any number of people may operate it.

Set Point Auto Reset


• Even if the set temperature is changed, it returns to the preset
temperature after a preset period of time.
• Period selectable from 30 min/60 min/90 min/120 min.

Off Timer
• Turns off the air conditioner after a preset period of time.
• Period can be preset from 30 to 180 minutes in 10-minute
increments.
Energy Savings : Centralized Control System
Precise energy management through REIRI
Improve operational cost & On-the-go
Easy access, monitor & control the VRV and connected devices anytime, from
efficiency, while reducing the
anywhere with Reiri Mobile App
management cost
Prevent unnecessary energy waste
Turn on & off all HVAC & connected devices when necessary

Schedule program to operate designated


management points and different areas

Setback to keep indoor temperature within setpoint and limit


energy consumption during absence

Interlock more management points of one area,


with condition and automate next action

Visualizing energy consumption to increase energy saving


Easily identify which energy consumed area that need to be improved
Comprehensive range of Reiri

Flagship Model
ReiriOffice
Touch ReiriOffice ReiriOffice Multi-site ReiriOffice Plus
DCPF04
DCPF01 DCPF10 DCPF05

ReiriHome ReirHome Lite ReiriHotel ReiriResort


DCPH01 DCPH02 DCPL01 DCPR01
Market transformation strategy Proposal – Industry to
Government

With successful launch of Star Labelling program in which RAMA collaborated with BEE in developing and implementation of
the program and the upgrades in tables subsequently. RAMA advocates to look at alternatives for energy efficiency/saving to
meet the NDC goals. One such initiative which is implemented is adoption 24 Degree Centigrade as default temperature. Apart
from reduction in energy consumptions through new equipment, RAMA is proposing to BEE to develop replacement policy for
old inefficient ACs that are 10 years plus old. This will have multiple benefits to all the stake holders

 Reduction in cost of energy bill annually


 Lower cost of service/maintenance/part replacement
 Reduction in carbon footprint which will help in contributing to meet NDC
 Meet the E waste targets as well establish the chain of recycling
 Growth for industry and thus bringing economy of scale to launch affordable AC
 Provide scale to bring competitiveness in conjunction with PLI scheme to create exports opportunities
 Encourage Make in India initiative of Government of India, establish competitive supply chain in India
 Additional revenue in form of GST to government
 Create employment across supply chain
 Encourage to MSME for local production of AC parts
Daikin Environmental Visit 2050
Gaurav Mehtani – Daikin
gaurav.mehtani@daikinindia.com
9711058337