Quick Atr Reset - Versão 1

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 44

[2]

[3]
ADC…………………………………………………………………..6
ADC 1+2…………………………………………………………..…7
AHRS………………………………………………………………...8
AHRS 1+2…………………………………………………………...9
AHRS NOT ALIGN…………………………………………………9
ALT DISAGREE…………………………………………………..10
ATT DISAGREE……….……………………………….………....11
AVNX CPM1……………………………………………………….12
AVNX CPM1+IOM22................................................................13
AVNX CPM1+IOM23................................................................14
AVNX CPM2.............................................................................15
AVNX CPM2+IOM12................................................................16
AVNX CPM2+IOM13................................................................17
AVNX IOM 12+13.....................................................................18
AVNX IOM 12+22.....................................................................18
AVNX IOM 12+23.....................................................................19
AVNX IOM 12+23.....................................................................19
AVNX IOM 13+23.....................................................................20
AVNX IOM 22+23.....................................................................20
AVNX IOM DC 12.....................................................................21
AVNX IOM DC 13.....................................................................21
AVNX IOM DC 22.....................................................................22
AVNX IOM DC 23.....................................................................22
AVNX SGL SWITCH……………………………………………...23
BAD CONF………………………………………………………...24
DATALINK…………………………………………………………24
DME LOSS………………………………………………………...25
FWS SGL CH……………………………………………………...26
GPWS………………………………………………………………26
HDG DISAGREE………………………………………………….27
HF.............................................................................................28
HF EMITTING……………………………………………………...29
IAS DISAGREE........................................................................30
MFC 1A....................................................................................30
MFC 1A + 1B............................................................................31

[4]
MFC 1A + 2A………………………………………………………31
MFC 1A + 2B FAULT………………………………………….....32
MFC 1B……………………………………………………....…….32
MFC 1B + 2A………………………………………………………33
MFC 1B + 2B...…….………………………………………...……33
MFC 2A…….………………………………………………………34
MFC 2A + 2B………………………………………………...……34
MFC 2B…………………………………………………………….35
RAD-ALT………………………………………………………..…36
RAD-ALT LOSS…………………………………………….........37
RMS………………………………………………………..............38
SGL DME……………………………………………................…39
TCAS……………………………………………………………….40
TERRAIN…………………………………………………….........41
VHF…………………………………………………………………42
XPDR……………………………………………………………….43
Flight attendant Panel……….................................................44

[5]
MESSAGE DISPLAYED ON EWD: ADC

ALERT DESCRIPTION: ONE ADC FAIL

MAINTENANCE ACTION:
Open during 5 sec. then close C/B MFC/1A AUX/ADC1 HOT
SPLY (B1) and PRIM REF/ADC1/ICP CAPT EMER SPLY (D5)
(21VU) to reset ADC1.

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM/REPORT/TEST/ADC1.

Open during 5 sec. then close C/B PRIM REF/ADC2/ICP F/O


GND SPLY (B5) (21VU) to reset ADC2.

Perform a system test.


On MCDU go to ACMS/AVS/CMS/SYSTEM
REPORT/TEST/ADC2.

IF THE ALERT PERSISTS, PERFORM TSM 34-10

Quick reference:
Minimum Equipment List MEL 34-11-01

[6]
MESSAGE DISPLAYED ON EWD: ADC 1+2

ALERT DESCRIPTION: ADC 1+2 LOSS

MAINTENANCE ACTION: Refer to ADC/ONE ADC FAIL.

IF THE ALERT PERSISTS, PERFORM TSM 34-10

Quick reference: go to page number “6”

[7]
MESSAGE DISPLAYED ON EWD: AHRS

ALERT DESCRIPTION: ONE AHRS FAIL

MAINTENANCE ACTION:
Open during 5 sec. then close C/B ATT/HDG/AHRS1 NORM
SPLY (D3) and ATT/HDG/AHRS1 AUX SPLY (C3) (21VU) to
reset AHRS1.

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM/REPORT/TEST/AHRS1.

Open during 5 sec. then close C/B ATT/HDG/AHRS2 AUX


SPLY-GND (D4) and ATT/HDG/AHRS2 NORM SPLY (C4)
(21VU) to reset AHRS2.

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/AHRS2.

IF THE ALERT PERSISTS, PERFORM TSM 34-10

Quick reference:
Minimum Equipment List MEL 34-20-1

[8]
MESSAGE DISPLAYED ON EWD: AHRS 1+2

ALERT DESCRIPTION: AHRS 1+2 LOSS

MAINTENANCE ACTION: Refer to AHRS/ONE AHRS FAIL.

IF THE ALERT PERSISTS, PERFORM TSM 34-25

Quick reference: go to page number “8”

MESSAGE DISPLAYED ON EWD: AHRS NOT ALIGN

ALERT DESCRIPTION: AHRS NOT ALIGN

MAINTENANCE ACTION:
Parking brake engaged, open during 5 sec. then close C/B
ATT/HDG/AHRS1 NORM SPLY (D3),
ATT/HDG/AHRS1 AUX SPLY (C3),
ATT/HDG/AHRS2 AUX SPLY-GND (D4) and
ATT/HDG/AHRS2 NORM SPLY (C4) (21VU).

NOTE: the aircraft must be stabilized on ground during at least


one minute before to perform the system test.

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/AHRS1
then AHRS2.

IF THE ALERT PERSISTS, PERFORM TSM 34-25

Quick reference:
Minimum Equipment List MEL 34-20-1

[9]
MESSAGE DISPLAYED ON EWD: ALT DISAGREE

ALERT DESCRIPTION: ALTITUDE DISAGREE

MAINTENANCE ACTION:
Open during 5 sec. then close C/B
MFC/1A AUX/ADC1 HOT SPLY (B1),
PRIM REF/ADC1/ICP CAPT EMER SPLY (D5) and
PRIM REF/ADC2/ICP F/O GND SPLY (B5) (21VU).

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/ADC1
then ADC2.

IF THE ALERT PERSISTS, PERFORM TSM 34-11

Quick reference:
Minimum Equipment List MEL 34-20-1

[ 10 ]
MESSAGE DISPLAYED ON EWD: ATT DISAGREE

ALERT DESCRIPTION: ATTITUDE DISAGREE

MAINTENANCE ACTION:
Open during 5 sec. then close C/B
ATT/HDG/AHRS1 NORM SPLY (D3),
ATT/HDG/AHRS1 AUX SPLY (C3),
ATT/HDG/AHRS2 AUX SPLY-GND (D4) and
ATT/HDG/AHRS2 NORM SPLY (C4) (21VU).

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/AHRS1
then AHRS2.

IF THE ALERT PERSISTS, PERFORM TSM 34-25

Quick reference:
Minimum Equipment List MEL 34-20-1

[ 11 ]
MESSAGE DISPLAYED ON EWD: AVNX CPM1

ALERT DESCRIPTION: AVNX CPM 1 LOSS

MAINTENANCE ACTION:
Parking brake or Gustlock engaged and engines 1 and 2 off.
Open during 5 sec. then close C/B CAC/CPM1/IOM-S1 (D6)
(21VU) to reset CPM1.

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM
REPORT/TEST/CAC1/CPM1.

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference:
Minimum Equipment List MEL 42-11-2

[ 12 ]
MESSAGE DISPLAYED ON EWD: AVNX CPM1+IOM22

ALERT DESCRIPTION: AVNX CPM 1 + IOM 22 LOSS

MAINTENANCE ACTION:
Parking brake or Gustlock engaged and engines 1 and 2 off.
Open during 5 sec. then close C/B CAC/CPM1/IOM-S1 (D6)
(21VU) to reset CPM1.

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM
REPORT/TEST/CAC1/CPM1.

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference:
Minimum Equipment List MEL 42-11-2

[ 13 ]
MESSAGE DISPLAYED ON EWD: AVNX CPM1+IOM23

ALERT DESCRIPTION: AVNX CPM 1 + IOM 23 LOSS

MAINTENANCE ACTION:
Parking brake or Gustlock engaged and engines 1 and 2 off.
Open during 5 sec. then close C/B CAC/CPM1/IOM-S1 (D6)
(21VU) to reset CPM1.

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM
REPORT/TEST/CAC1/CPM1.

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference:
Minimum Equipment List MEL 42-11-2

[ 14 ]
MESSAGE DISPLAYED ON EWD: AVNX CPM2

ALERT DESCRIPTION: AVNX CPM 2 LOSS

MAINTENANCE ACTION:
Parking brake or Gustlock engaged and engines 1 and 2 off.
Open during 5 sec. then close C/B CAC/CPM2/IOM-S2 NORM
SPLY (C6) (21VU) to reset CPM2.

Perform a system test.


On MCDU go to
ACMS/AVS/SYSTEM REPORT/TEST/CAC2/CPM2.

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference:
Minimum Equipment List MEL NO GO item

[ 15 ]
MESSAGE DISPLAYED ON EWD: AVNX CPM2+IOM12

ALERT DESCRIPTION: AVNX CPM 2 + IOM 12 LOSS

MAINTENANCE ACTION:
Parking brake or Gustlock engaged and engines 1 and 2 off.
Open during 5 sec. then close C/B CAC/CPM2/IOM-S2 NORM
SPLY (C6) (21VU) to reset CPM2.

Perform a system test.


On MCDU go to
ACMS/AVS/SYSTEM REPORT/TEST/CAC2/CPM2.

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference:
Minimum Equipment List MEL NO GO item

[ 16 ]
MESSAGE DISPLAYED ON EWD: AVNX CPM2+IOM13

ALERT DESCRIPTION: AVNX CPM 2 + IOM 13 LOSS

MAINTENANCE ACTION:
Parking brake or Gustlock engaged and engines 1 and 2 off.
Open during 5 sec. then close C/B CAC/CPM2/IOM-S2 NORM
SPLY (C6) (21VU) to reset CPM2.

Perform a system test.


On MCDU go to
ACMS/AVS/SYSTEM REPORT/TEST/CAC2/CPM2.

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference:
Minimum Equipment List MEL NO GO item

[ 17 ]
MESSAGE DISPLAYED ON EWD: AVNX IOM 12+13

ALERT DESCRIPTION: AVNX IOM 12 + 13 LOSS

MAINTENANCE ACTION: Refer to AVNX IOM DC 12 and to


AVNX IOM DC 13.

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference: go to page number “21”

MESSAGE DISPLAYED ON EWD: AVNX IOM 12+22

ALERT DESCRIPTION: AVNX IOM 12 + 22 LOSS

MAINTENANCE ACTION: Refer to AVNX IOM DC 12 and to


AVNX IOM DC 22.

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference: go to pages number “21 and 22”

[ 18 ]
MESSAGE DISPLAYED ON EWD: AVNX IOM 12+23

ALERT DESCRIPTION: AVNX IOM 12 + 23 LOSS

MAINTENANCE ACTION: Refer to AVNX IOM DC 12 and to


AVNX IOM DC 23.

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference: go to pages number “21 and 22”

MESSAGE DISPLAYED ON EWD: AVNX IOM 13+22

ALERT DESCRIPTION: AVNX IOM 13 + 22 LOSS

MAINTENANCE ACTION: Refer to AVNX IOM DC 13 and to


AVNX IOM DC 22.

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference: go to page number “21 and 22”

[ 19 ]
MESSAGE DISPLAYED ON EWD: AVNX IOM 13+23

ALERT DESCRIPTION: AVNX IOM 13 + 23 LOSS

MAINTENANCE ACTION: Refer to AVNX IOM DC 13 and to


AVNX IOM DC 23.

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference: go to pages number “21 and 22”

MESSAGE DISPLAYED ON EWD: AVNX IOM 22+23

ALERT DESCRIPTION: AVNX IOM 22 + 23 LOSS

MAINTENANCE ACTION: Refer to AVNX IOM DC 22 and to


AVNX IOM DC 23.

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference: go to page number “22”

[ 20 ]
MESSAGE DISPLAYED ON EWD: AVNX IOM DC 12

ALERT DESCRIPTION: AVNX IOM 12 LOSS

MAINTENANCE ACTION: Open during 5 sec. then close C/B


CAC/IOM-DC/12 (D8) (21VU).

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference:
Minimum Equipment List MEL NO GO item

MESSAGE DISPLAYED ON EWD: AVNX IOM DC 13

ALERT DESCRIPTION: AVNX IOM 13 LOSS

MAINTENANCE ACTION: Open during 5 sec. then close C/B


CAC/CPM1/IOM-S1 (D6) and CAC/IOM-DC/12 (D8) (21VU).

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference:
Minimum Equipment List MEL NO GO item

[ 21 ]
MESSAGE DISPLAYED ON EWD: AVNX IOM DC 22

ALERT DESCRIPTION: AVNX IOM 22 LOSS

MAINTENANCE ACTION: Open during 5 sec. then close C/B


CAC/IOM-DC/22 (C8) (21VU).

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference:
Minimum Equipment List MEL NO GO item

MESSAGE DISPLAYED ON EWD: AVNX IOM DC 23

ALERT DESCRIPTION: AVNX IOM 23 LOSS

MAINTENANCE ACTION: Open during 5 sec. then close C/B


CAC/IOM-DC/23 (C9) (21VU).

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference:
Minimum Equipment List MEL NO GO item

[ 22 ]
MESSAGE DISPLAYED ON EWD: AVNX SGL SWITCH

ALERT DESCRIPTION: AVNX SGL SWITCH

MAINTENANCE ACTION:
Parking brake or Gustlock engaged and engines 1 and 2 off.
Open during 5 sec. then close C/B
CAC/IOM-DC/12 (D8),
CAC/IOM-DC/22 (C8),
CAC/IOM-DC/13 (D9) and
CAC/IOM-DC/23 (C9) (21VU).

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/SWM1.

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/SWM2.

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference:
Minimum Equipment List MEL NO GO item

[ 23 ]
MESSAGE DISPLAYED ON EWD: BAD CONF

ALERT DESCRIPTION: None

MAINTENANCE ACTION: Switch off during 5 sec. then switch


on the DU1 and DU5.

IF THE ALERT PERSISTS, PERFORM TSM 31-63

Quick reference:
Minimum Equipment List MEL 31-60-1

MESSAGE DISPLAYED ON EWD: DATALINK

ALERT DESCRIPTION: None

MAINTENANCE ACTION:
Open during 5 sec. then close C/B COM/ACARS CMU (B16)
(21VU).

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/CMU.

IF THE ALERT PERSISTS, PERFORM TSM 23-24

Quick reference:
Minimum Equipment List MEL 23-24-1

[ 24 ]
MESSAGE DISPLAYED ON EWD: DME LOSS

ALERT DESCRIPTION: None

MAINTENANCE ACTION:
Open during 5 sec. then close C/B NAV/COM/SURV/DME1
(D17) (21VU) to reset DME1.

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/DME1.

Open during 5 sec. then close C/B NAV/COM/SURV/DME2


(C17) (21VU) to reset DME2.

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/DME2.

IF THE ALERT PERSISTS, PERFORM TSM 34-51

Quick reference:
Minimum Equipment List MEL 34-51-1

[ 25 ]
MESSAGE DISPLAYED ON EWD: FWS SGL CH

ALERT DESCRIPTION: AVNX FWS SGL CH

MAINTENANCE ACTION:
Make sure that parking brake is "ON" (or Gustlock engaged)
and engines 1 and 2 off.

Open during 5 sec. then close C/B CAC/CPM1/IOM-S1 (D6)


(21VU) to reset CPM1.
Open during 5 sec. then close C/B CAC/CPM2/IOM-S2 NORM
SPLY (C6) (21VU) to reset CPM2.

IF THE ALERT PERSISTS, PERFORM TSM 42-11

Quick reference:
Minimum Equipment List MEL NO GO item

MESSAGE DISPLAYED ON EWD: GPWS

ALERT DESCRIPTION: None

MAINTENANCE ACTION:
Open C/B SUR/T2CAS/T-R (A22) (21VU) during 5 sec. then
close it to reset computer T2CAS.

Perform a system test.


On MCDU go to
ACMS/AVS/SYSTEM REPORT/TEST/XPDR1/T2CAS.

IF THE ALERT PERSISTS, PERFORM TSM 34-48

Quick reference:
Minimum Equipment List MEL 34-48-2

[ 26 ]
MESSAGE DISPLAYED ON EWD: HDG DISAGREE

ALERT DESCRIPTION: HEADING DISAGREE

MAINTENANCE ACTION:
Open during 5 sec. then close C/B
ATT/HDG/AHRS1 NORM SPLY (D3),
ATT/HDG/AHRS1 AUX SPLY (C3),
ATT/HDG/AHRS2 AUX SPLY-GND (D4) and
ATT/HDG/AHRS2 NORM SPLY (C4) (21VU).

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/AHRS1
then AHRS2.

IF THE ALERT PERSISTS, PERFORM TSM 34-25

Quick reference:
Minimum Equipment List MEL 34-20-1

[ 27 ]
MESSAGE DISPLAYED ON EWD: HF

ALERT DESCRIPTION: None

MAINTENANCE ACTION:
Open during 5 sec. then close C/B HF1/T-R () to reset HF1.

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/HF1.

Open during 5 sec. then close C/B HF2/T-R () to reset HF2.

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/HF2.

IF THE ALERT PERSISTS, PERFORM TSM 23-11

Quick reference:
Minimum Equipment List MEL 23-11-1

[ 28 ]
MESSAGE DISPLAYED ON EWD: HF EMITTING

ALERT DESCRIPTION: None

MAINTENANCE ACTION:
Open during 5 sec. then close C/B HF1/T-R () to reset HF1.

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/HF1.

Open during 5 sec. then close C/B HF2/T-R () to reset HF2.

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/HF2.

IF THE ALERT PERSISTS, PERFORM TSM 23-11

Quick reference:
Minimum Equipment List MEL 23-11-1

[ 29 ]
MESSAGE DISPLAYED ON EWD: IAS DISAGREE

ALERT DESCRIPTION: IAS DISAGREE

MAINTENANCE ACTION:
Open during 5 sec. then close C/B PRIM REF/ADC1/ICP CAPT
EMER SPLY (D5) and PRIM REF/ADC2/ICP F/O GND SPLY
(B5) (21VU).

Perform a system test.


On MCDU go to
ACMS/AVS/SYSTEM REPORT/TEST/ADC1 then ADC2.

IF THE ALERT PERSISTS, PERFORM TSM 34-11

Quick reference:
Minimum Equipment List MEL 34-13-1

MESSAGE DISPLAYED ON EWD: MFC 1A

ALERT DESCRIPTION: MFC 1A FAULT

MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/1A,
P/BSW – MFC/1B and P/BSW – MFC/2B, wait 5 sec.
Then press P/BSW – MFC/1B and P/BSW – MFC/2B and when
they stop to flash, press P/BSW – MFC/1A.

IF THE ALERT PERSISTS, PERFORM TSM 31-48

Quick reference:
Minimum Equipment List MEL NO GO ITEM

[ 30 ]
MESSAGE DISPLAYED ON EWD: MFC 1A + 1B

ALERT DESCRIPTION: MFC 1A + 1B FAULT

MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/1A,
P/BSW – MFC/1B and P/BSW – MFC/2B, wait 5 sec.
Then press P/BSW – MFC/2B and when it stop to flash, press
P/BSW – MFC/1A and P/BSW – MFC/1B.

IF THE ALERT PERSISTS, PERFORM TSM 31-48

Quick reference:
Minimum Equipment List MEL NO GO ITEM

MESSAGE DISPLAYED ON EWD: MFC 1A + 2A

ALERT DESCRIPTION: MFC 1A + 2A FAULT

MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/1A,
P/BSW – MFC/2A, P/BSW – MFC/1B and P/BSW – MFC/2B,
wait 5 sec.
Then press P/BSW – MFC/1B and P/BSW – MFC/2B and when
they stop to flash, press P/BSW – MFC/1A and P/BSW –
MFC/2A.

IF THE ALERT PERSISTS, PERFORM TSM 31-48

Quick reference:
Minimum Equipment List MEL NO GO ITEM

[ 31 ]
MESSAGE DISPLAYED ON EWD: MFC 1A + 2B

ALERT DESCRIPTION: MFC 1A + 2B FAULT

MAINTENANCE ACTION:

On panel 25VU, depress the pushbuttons P/BSW – MFC/1A,


P/BSW – MFC/2B and P/BSW – MFC/1B, wait 5 sec.
Then press P/BSW – MFC/1B and when it stop to flash, press
P/BSW – MFC/1A and P/BSW – MFC/2B.

IF THE ALERT PERSISTS, PERFORM TSM 31-48

Quick reference:
Minimum Equipment List MEL NO GO ITEM

MESSAGE DISPLAYED ON EWD: MFC 1B

ALERT DESCRIPTION: MFC 1B FAULT

MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/1B
and P/BSW – MFC/2B, wait 5 sec.
Then press P/BSW – MFC/2B and when it stop to flash, press
P/BSW – MFC/1B.

IF THE ALERT PERSISTS, PERFORM TSM 31-48

Quick reference:
Minimum Equipment List MEL NO GO ITEM

[ 32 ]
MESSAGE DISPLAYED ON EWD: MFC 1B + 2A

ALERT DESCRIPTION: MFC 1B + 2A FAULT

MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/1B,
P/BSW – MFC/2B, P/BSW – MFC/2B, wait 5 sec.
Then press P/BSW – MFC/2B and when it stop to flash, press
P/BSW – MFC/1B and P/BSW – MFC/2B.

IF THE ALERT PERSISTS, PERFORM TSM 31-48

Quick reference:
Minimum Equipment List MEL NO GO ITEM

MESSAGE DISPLAYED ON EWD: MFC 1B + 2B

ALERT DESCRIPTION: MFC 1B + 2B FAULT

MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/1B,
P/BSW – MFC/2B, P/BSW – MFC/1A and P/BSW – MFC/2B,
wait 5 sec.
Then press P/BSW – MFC/1A and P/BSW – MFC/2B and when
they stop to flash, press P/BSW – MFC/1B and P/BSW –
MFC/2B.

IF THE ALERT PERSISTS, PERFORM TSM 31-48

Quick reference:
Minimum Equipment List MEL NO GO ITEM

[ 33 ]
MESSAGE DISPLAYED ON EWD: MFC 2A

ALERT DESCRIPTION: MFC 2A FAULT

MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/2B,
P/BSW – MFC/1B and P/BSW – MFC/2B, wait 5 sec.
Then press P/BSW – MFC/1B and P/BSW – MFC/2B and when
they stop to flash, press P/BSW – MFC/2B.

IF THE ALERT PERSISTS, PERFORM TSM 31-48

Quick reference:
Minimum Equipment List MEL NO GO ITEM

MESSAGE DISPLAYED ON EWD: MFC 2A + 2B

ALERT DESCRIPTION: MFC 2A + 2B FAULT

MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/2B,
P/BSW – MFC/2B and P/BSW – MFC/1B, wait 5 sec.
Then press P/BSW – MFC/1B and when it stop to flash, press
P/BSW – MFC/2B and P/BSW – MFC/2B.

IF THE ALERT PERSISTS, PERFORM TSM 31-48

Quick reference:
Minimum Equipment List MEL NO GO ITEM

[ 34 ]
MESSAGE DISPLAYED ON EWD: MFC 2B

ALERT DESCRIPTION: MFC 2B FAULT

MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/2B
and P/BSW – MFC/1B, wait 5 sec.
Then press P/BSW – MFC/1B and when it stop to flash, press
P/BSW – MFC/2B.

IF THE ALERT PERSISTS, PERFORM TSM 31-48

Quick reference:
Minimum Equipment List MEL NO GO ITEM

[ 35 ]
MESSAGE DISPLAYED ON EWD: RAD-ALT

ALERT DESCRIPTION: ONE RAD-ALT FAIL

MAINTENANCE ACTION:
Open during 5 sec. then close C/B NAV/COM/SUR/RA1 (D21)
(21VU).

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/RA1.

If mod. 05967 is installed, open during 5 sec. then close C/B


NAV/COM/SUR/RA2 (C21) (21VU).

Perform a system test.


On MCDU go to ACMS/AVS/SYSTEM REPORT/TEST/RA2.

IF THE ALERT PERSISTS, PERFORM TSM 34-42

Quick reference:
Minimum Equipment List MEL 34-42-1

[ 36 ]
MESSAGE DISPLAYED ON EWD: RAD-ALT LOSS

ALERT DESCRIPTION: RAD-ALT LOSS

MAINTENANCE ACTION:
Open during 5 sec. then close C/B (D21) (21VU).

Perform a system test.


On MCDU go to ACMS/AVS/”SYSTEM REPORT/TEST”/RA1.

If mod. 05967 is installed, open during 5 sec. then close C/B


(C21) (21VU).

Perform a system test.


On MCDU go to ACMS/AVS/”SYSTEM REPORT/TEST”/RA2.

IF THE ALERT PERSISTS, PERFORM TSM 34-42

Quick reference:
Minimum Equipment List MEL 34-42-1

[ 37 ]
MESSAGE DISPLAYED ON EWD: RMS

ALERT DESCRIPTION: None

MAINTENANCE ACTION:
Switch off DU2 during 5 sec. then switch on DU2. On MCDU go
to ACMS/AVS/CMS//SYSTEM REPORT/TEST/DU2.
Switch off DU4 during 5 sec. then switch on DU4. On MCDU go
to ACMS/AVS/CMS//SYSTEM REPORT/TEST/DU4.

NOTE: when DU2 or DU4 is switched off, RMS 1+2 can be


displayed on EWD alert window.

IF THE ALERT PERSISTS, PERFORM TSM 31-63

Quick reference:
Minimum Equipment List MEL 31-60-1

[ 38 ]
MESSAGE DISPLAYED ON EWD: SGL DME

ALERT DESCRIPTION: None

MAINTENANCE ACTION:
Open during 5 sec. then close C/B (17D) (21VU) to reset
DME1.
Perform a system test.
On MCDU go to ACMS/AVS/”SYSTEM REPORT/TEST”/DME1.

Open during 5 sec. then close C/B (17C) (21VU) to reset


DME2.
Perform a system test.
On MCDU go to ACMS/AVS/”SYSTEM REPORT/TEST”/DME2.

IF THE ALERT PERSISTS, PERFORM TSM 34-51

Quick reference:
Minimum Equipment List MEL 34-51-1

[ 39 ]
MESSAGE DISPLAYED ON EWD: TCAS

ALERT DESCRIPTION: None

MAINTENANCE ACTION:
Open during 5 sec. then close C/B (A22) (21VU) to reset
computer T2CAS.

Perform a system test.


On MCDU go to
ACMS/AVS/”SYSTEM REPORT/TEST”/XPDR1/T2CAS.

IF THE ALERT PERSISTS, PERFORM TSM 34-43

Quick reference:
Minimum Equipment List MEL 34-57-1

[ 40 ]
MESSAGE DISPLAYED ON EWD: TERRAIN

ALERT DESCRIPTION: None

MAINTENANCE ACTION:
Open during 5 sec. then close C/B (A22) (21VU) to reset
computer T2CAS.

Perform a system test.


On MCDU go to
ACMS/AVS/”SYSTEM REPORT/TEST”/XPDR1/T2CAS.

IF THE ALERT PERSISTS, PERFORM TSM 34-48

Quick reference:
Minimum Equipment List MEL 34-57-1

[ 41 ]
MESSAGE DISPLAYED ON EWD: VHF

ALERT DESCRIPTION: None

MAINTENANCE ACTION:
Open during 5 sec. then close C/B (20D) (21VU) to reset VHF1.
Perform a system test.
On MCDU go to ACMS/AVS/”SYSTEM REPORT/TEST”/VHF1.

Open during 5 sec. then close C/B (20C) (21VU) to reset VHF2.
Perform a system test.
On MCDU go to ACMS/AVS/”SYSTEM REPORT/TEST”/VHF2.

Open during 5 sec. then close C/B (20B) (21VU) to reset VHF3.
Perform a system test.
On MCDU go to ACMS/AVS/”SYSTEM REPORT/TEST”/VHF3.

IF THE ALERT PERSISTS, PERFORM TSM 23-12

Quick reference:
Minimum Equipment List MEL 23-12-1

[ 42 ]
MESSAGE DISPLAYED ON EWD: XPDR

ALERT DESCRIPTION: None

MAINTENANCE ACTION:
Open during 5 sec. then close C/B (19D) (21VU) to reset
XPDR1.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM REPORT/TEST”/XPDR1/T2CAS.

Open during 5 sec. then close C/B (19C) (21VU) to reset


XPDR2.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM REPORT/TEST”/XPDR2/T2CAS.

IF THE ALERT PERSISTS, PERFORM TSM 34-52

Quick reference:
Minimum Equipment List MEL 34-57-1

[ 43 ]
MESSAGE DISPLAYED ON EWD: Flight attendant Panel

ALERT DESCRIPTION: Panel frozen

MAINTENANCE ACTION:
Open during 5 sec. then close C/B (K25) and (K24) (122VU) or
press the reset pushbutton located on the front face of the FAP
to reset it.

IF THE ALERT PERSISTS, PERFORM

Quick reference:
Minimum Equipment List MEL

[ 44 ]

You might also like