CENTRIFUGAL PUMP DATA SHEET FOR HORIZONTAL PUMPS AND VERTICAL IN-LINE PUMPS
REVISION DESCRIPTION

NOTE: BY MANUFACTURER OF PUMPS PER ASME B 73.1 OR B 73.2


INDICATES INFORMATION TO BE COMPLETED BY PURCHASER; BY MANUFACTURER OF PUMPS OR PUMPS PER 31-SAMSS-004
CONSTRUCTION DATA (CONT'D) CONSTRUCTION DATA (CONT'D)
FORCES AND MOMENTS STUFFING BOX DATA
/ ALLOWABLE FORCES AND MOMENTS
TOP NOZZLE SIDE NOZZLE END NOZZLE EACH NOZZLE INBOARD / OUTBOARD

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
Fx 800 LB Fx 1050 LB Fx LB Mx 500/900 LB.FT INSIDE DIAMETER IN 1.97
Fy 1350 LB Fy 1240 LB Fy LB My 550/450 LB.FT DEPTH IN 1.38
Fz 3000 LB Fz 1250 LB Fz LB Mz 510/450 LB.FT DISTANCE FACE OF STUFFING BOX
DATE

BI-10-09003

MISC CONNECTIONS QTY. SIZE TYPE FLANGE TO NEAREST OBSTRUCTION IN 2.24


JOB ORDER/EWO NO.

LUBE OIL INLET NA NA NA


LUBE OIL OUTLET NA NA NA
SEAL LIQUID INLET NA NA NA IMPELLER DATA
REV. NO.

SEAL (PLAN 61) LIQUID DRAIN 1 1/2" 150# RF FIRST FOLLOW


CASING DRAIN(S) 1 1/2" 150# RF NUMBER OF STAGES SINGLE STAGE STAGE

VENTS SELF - - / ACTUAL DIAMETER IN 4.37


COOLING WATER NA NA NA / MAXIMUM DIAMETER IN 6
STUFFING BOX NA NA NA / MINIMUM DIAMETER IN 4
BY/DATE
OTHER

BALANCE DRUM NA NA NA SINGLE / DOUBLE SUCTION SINGLE


DRAIN & VENT INDIVIDUALLY PIPED WITH BLOCK VALVES TO TERMINATE / EYE AREA IMPELLER SQ.IN 4.7
O
AT EDGE OF BASE PLATE IN COMMON AREA YES NO VANE ANGLE AT IMP. EXIT -
FLANGE RATING 2" NPTF in CLASS / NUMBER OF VANES 5
ACTUAL PERIPHERAL SPEED FT/S 67.07664
OPERATIONS/DATE

PRESSURES MAX.ALLOW.PERIPH.SP'D AT FLOW TEMP. FT/S 92.09607


MAX. ALLOW. / PATTERN NUMBER -
WORK. PRESS. HYDROST.
/ PRECISION CAST YES - NO NO
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)

TEST PRESS
O
/ PRESSURES AT Amb F / CUT WATER DIAMETER IN 6.31
CASE PSIG 232 348 SPECIFIC SPEED 1273
JACKETS PSIG / SUCTION SPECIFIC SPEED AT 3% DH 9029
COILS PSIG WIDTH. IMPELLER DISCH. IN 0.4
CONST. AGENCY/DATE

DUAL MECH. UNDER / OVER FILING / V-CUT YES / NO NO


SEAL PSIG WEARING RINGS:
IMPELLER YES NO
SHAFT DATA CASE YES NO
SHAFT DIAMETER AT MECH. SEAL SLEEVE IN 1.13 ELEMENT DIAMETER CLEARANCE
SHAFT DIAMETER AT BEARINGS IN 1.58 FRONT IMPELLER WEAR RING NA
SHAFT DIAMETER AT 1ST STAGE IMPELLER IN 0.75 BACK IMPELLER WEAR RING NA
BEARING SPAN IN 3.66 CENTER BUSHING
CERTIFIED/DATE

STATIC SHAFT DEFLECTION IN 0.002 THROTTLE/BALANCE DRUM


DESIGN CERTIFICATION

SHAFT SEALING
(DESIGN AGENCY)

PACKED STUFFING BOX PACKING MAT'L. NA 1st STAGE IMPELLER INLET GEOMETRY
PROVIDED WITH LANTERN RING: YES NO
SEALING ARRANGEMENT THROUGH SEALING
DEAD ENDED
ENGG./DATE

FLUSH WITH LIQUID PUMPED GREASE


FOREIGN LIQUID BLEED OFF
MECHANICAL SEAL API CODE - (Note M4) C1A1A (1CW-FX)
ap
/ MAKE JOHN CRANE
/ MANUFACTURER MAT'L CODE X P147 1 X D86 H 316/HC ah
/ MODEL 5610VQ SINGLE CARTRIDGE
/ API CODE MAT'L 3RD LETTER BSTFN
IS COVERED, FOR ALL APPROVAL AND

4TH LETTER
CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER DRAWING

Dh1

Dh2
Dsl
Dp

5TH LETTER
d

PIPING FOR PRIMARY SEAL API FIG. D-2 PLAN 11 / 61 (Note M4) Dp = NA IN

PIPING FOR THROTTLE BUSHING OR Dsl = NA IN (IF APPLICABLE)

AUXILIARY SEAL API FIG. D-3 PLAN Dh1 = NA IN


REVISION VALIDATION

COOLING WATER PIPING, API FIG. D-4 PLAN Dh2 = NA IN

CYCLONE SEPARATOR YES NO d = NA IN

FLOW ORIFICE IN SEAL FLUSH SUPPLY LINE YES NO ap = NA DEGREES

SEAL LEAKAGE PIPING WITH ORIFICE YES NO ah = NA DEGREES


COMPLETION CERTIFICATE NO.

BUFFER LIQUID SYSTEM YES NO

METHANOL DRIP SYSTEM YES NO

/ REQUIRED: PRESSURE PSIG; FLOW USGPM


THIS REVISION NO.

CARTRIDGE DESIGN YES NO

MECHANICAL DATA SHEET FOR MEG PIPELINE CORROSION INHIBITORDWG.


UNLOADING
TYPE PUMP
PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.

T70-G-0008 A/B - MEG PL CORROSION INHIBITOR UNLOADING PUMPS DAT


INLET FACILITIES - PACKAGE 9 T70 G CE-795877 3 B
TANAJIB SAUDI ARABIA
# SULZER CONFIDENTIAL EKRD/2741-2-0915.XLS
Saudi Aramco 2741-ENG (09/2015)

SAUDI ARABIAN OIL COMPANY

THIS REVISION IS NOT TO BE USED FOR


CONSTRUCTION UNTIL CERTIFIED AND
CENTRIFUGAL PUMP DATA SHEET FOR HORIZONTAL PUMPS AND VERTICAL IN-LINE PUMPS
NOTE: BY MANUFACTURER OF PUMPS PER ASME B 73.1 OR B 73.2

INDICATES INFORMATION TO BE COMPLETED BY PURCHASER; BY MANUFACTURER OF PUMPS OR PUMPS PER 31-SAMSS-004

DATED
PURCHASERS REFERENCES SITE CONDITIONS

APPLICABLE TO: PROPOSALS PURCHASE AS BUILT INDOOR OUTDOOR (Note M8) UNDER ROOF
REVISION DESCRIPTION

ON SHORE COASTAL OFF SHORE

/ PUMP MFR SULZER SAUDI PUMP COMPANY LIMITED ELECTRICAL AREA CLASS 1 , DIV. 2 , GROUP IIA/IIB, T3
/ SIZE & TYPE SPCP 3x1.5x6
/ SERIAL NO. S8212446 & S8212447 PERFORMANCE DATA
DRIVER TYPE ELECTRIC MOTOR PERFORMANCE
THIS DATA SHEET COVER 2 (Note P6) PUMP(S)

PUMP MARK NO(S). T70 -G- 0008 A - -G- / / RATED SPEED RPM 3515
BI-10-09003
DATE

T70 -G- 0008 B - -G- / / DRIVER NAME PLATE POWER RATING HP 7.5
JOB ORDER/EWO NO.

/ PUMPS OF IDENTICAL TYPE & SIZE IN OPERATION RPM 3560

-G- - -G- / / PERFORMANCE AT 100% 120%


REV. NO.

MIN. CONT.STABLE NORMAL


-G- - -G- FLOW FLOW OF RATED
CAPACITY
DRIVER DATA SHEET REFER TO SHEETS 9 & 10
GEAR UNIT DATA SHEET TOTAL DIFF. HEAD Ft 77.08 70.3 70.3 66.07
LUBE OIL SYST DATA SHEET EFFICIENCY % 24.4 36.47 36.47 38.63
SAFETY INSTRUCTION SHEET REQUIRED POWER HP 3.76 4.41 4.41 4.7
BY/DATE
OTHER

LCC EF $/kW NPSH REQ'D FOR:

3% DH 1st STAGE ON H2O Ft 6.92 7.34 7.34 7.58

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
40,000 HRS LIQ'D PUMPED Ft NA NA NA NA
SERVICE
/ SHUT-OFF HEAD AT ACTUAL IMP. DIAM. Ft 83.74
OPERATIONS/DATE

MEG PIPELINE CORROSION INHIBITOR


PUMP FUNCTION AT MAX. IMP. DIAM. Ft 159
UNLOADING PUMP
CONTINUOUS INTERMITTENT STANDY BY CAPACITY AT END OF CURVE USGPM 166.1

ATTENDED UNATTENDED CAPACITY AT BEST EFFICIENCY POINT USGPM 127.7


INDIVIDUALLY IN SERIES IN PARALLEL TOT.DIFF. HEAD AT END OF CURVE Ft 47.08
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)

UPSTREAM OF PUMP NO(S) -G- RATIO. SHUT-OFF HEAD/RATED HEAD 1.191180654

-G- RATIO. END OF CURVE CAPACITY/RATED CAP. 1.451136364


DOWNSTREAM OF PUMP NO(S) -G- MINIMUM CONTINUOUS STABLE FLOW USGPM 43.8

-G- MINIMUM CONTINUOUS THERMAL FLOW USGPM NA


CONST. AGENCY/ DATE

MAXIMUM OPERATING TIME AT SHUT-OFF SEC 30

FIRST CRIT. SPEED; DRY RPM 24556

LIQUID CHARACTERISTICS FIRST CRIT. SPEED; WET RPM NA

MAX. ALLOWABLE SPEED RPM 3600


CORROSION INHIBITOR
LIQUID PUMPED TDS NONE PPM MAX. POWER FULL CURVE ACTUAL IMP. DIAM. HP 5.53
(Note P11)
O
NORMAL FLOW TEMPERATURE F 120 POWER AT SHUT-OFF HEAD HP 2.99
O
MAX. FLOW TEMPERATURE F 120 PERFORMANCE WITH MAX. AND

RELATIVE DENSITY AT NORMAL FLOW TEMP. 1.03 MIN. IMPELLER DIAMETERS


CERTIFIED/DATE

VISCOSITY AT FLOW TEMP. CS / CP / SSU 100 MAX. MIN.


VAPOR PRESSURE AT NORMAL TOT.DIFF. HEAD AT RATED CAPACITY Ft 143.8 57.67
DESIGN CERTIFICATION

FLOW TEMP. PSIA 1.5 EFFICIENCY AT RATED CAPACITY % 35.57 36.41


(DESIGN AGENCY)

V.P. AT MAX. FLOW TEMP. PSIA 1.5 REQUIRED POWER AT RATED CAP. HP 9.25 3.62
TSS NONE 300 (NOTE M10) PPM UNKNOWN MAX. REQUIRED POWER FULL CURVE HP 13.14 4.38

CHARACTER OF PULPY GRITTY HARD SOFT


SOLIDS: INTERMEDIATE TRANSMISSION
ENGG./DATE

GAS IN FLUID: NONE VOL. % UNKNOWN / GEAR BOX RATIO NA


PRINCIPAL CORROSIVES: NONE / HYDR. COUPL. SPEED RANGE NA % NA % OF DRIVER SPEED

pH 5.5-6.5 CI NONE PPM

CONSTRUCTION DATA
PUMP TYPE
OPERATING CONDITIONS HORIZONTAL (BET. BRGS) / OVERHUNG

/ VERT. IN-LINE INTEGRAL SHAFT

CAPACITY (Note P5,P7) NORMAL USGPM 88 CASING MOUNT: CENTERLINE FLANGE CENTERLINE
IS COVERED, FOR ALL APPROVAL

RATED USGPM 88 FOOT

RATED TOTAL DIFFERENTIAL HEAD Ft 70.3 VERT. IN-LINE IN-LINE CASE SUPPORTED
AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER

NPSH AVAILABLE AT SUCTION FLG. CASING SPLIT AXIAL RADIAL

AT RATED CAPACITY Ft 25 (Note P3) CASING TYPE DOUBLE VOLUTE SINGLE VOLUTE
REVISION VALIDATION

AT 120% OF RATED CAPACITY Ft 24 (Note P4) DIFFUSOR STAGGER

VISC. CORR. FACTOR CQ; CH; CE 0.92 0.93 0.67 SELF PRIMING / YES / NO
DRAWING COMPLETION CERTIFICATE NO.

RATED SUCTION PRESSURE PSIA 14.1 DIR. OF ROT. / / CCW / / CW

MAX. SUCT. PR. AT RATED CAP. PSIA 128 (VIEWED FROM DRIVER)

MAX. SUCT. PR. AT SHUT-OFF PSIA 130 PUMP NOZZLES


TOTAL DIFFERENTIAL PRESSURE PSI 31.4 SIZE RATING FACING LOCATION

RATED DISCHARGE PRESSURE PSIA 45.5 / SUCTION 3" 150# RF SIDE


THIS REVISION NO.

MAX. DISCH. PR. AT RATED CAP. PSIA 162 / DISCHARGE 1.5" 150# RF TOP
HYDRAULIC POWER HP 1.6
MECHANICAL DATA SHEET FOR MEG PIPELINE CORROSION INHIBITOR UNLOADING
DWG. TYPE PUMP
PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.

T70-G-0008 A/B - MEG PL CORROSION INHIBITOR UNLOADING PUMPS DAT


INLET FACILITIES - PACKAGE 9 T70 G CE-795877 2 B
TANAJIB SAUDI ARABIA
EKRD/2741-1-0915.XLS
SULZER CONFIDENTIAL
#
SAUDI ARABIAN OIL COMPANY

THIS REVISION IS NOT TO BE USED FOR


CONSTRUCTION UNTIL CERTIFIED AND
CENTRIFUGAL PUMP DATA SHEET FOR HORIZONTAL PUMPS AND VERTICAL IN-LINE PUMPS
NOTE: BY MANUFACTURER OF PUMPS PER ASME B 73.1 OR B 73.2

INDICATES INFORMATION TO BE COMPLETED BY PURCHASER; BY MANUFACTURER OF PUMPS OR PUMPS PER 31-SAMSS-004

CONSTRUCTION DATA (CONT'D) CONSTRUCTION DATA (CONT'D)

DATED
BEARINGS AND LUBRICATION COUPLING
BEARING TYPE RADIAL THRUST / MAKE JOHN CRANE MODEL TDKS SIZE 95.3MM

SLEEVE SUPPLIED BY: SULZER SAUDI PUMP COMPANY LIMITED


ANTI-FRICTION TYPE
REVISION DESCRIPTION

TILTING PAD DIAPHRAGM OR DISC PACK

LUBRICATION METHOD RADIAL THRUST RIGID ADJUSTABLE

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
GREASE CLOSE COUPLED

RING-OIL CONSTANT LEVEL ELASTOMERIC

/ LUBRICATOR, MAKE TRICO HYDRAULIC FIT KEYED

OIL BATH WITH EXT'L CIRCULATION SPACER: YES, 3.75 IN NO


FORCED FEED COUPLING GUARD PARTIALLY ENCLOSED COMPLETELY ENCLOSED
BI-10-09003

OIL MIST PUMP SHAFT END CYLINDRICAL TAPERED


DATE

LUBE OIL PIPING TO AND MOUNT COUPLING HALF: PUMP YES NO


JOB ORDER/EWO NO.

FROM BEARINGS YES NO DRIVER HALF YES NO. IF SHIPPED TO DRIVER SUPPLIER
LUBE OIL PIPING UP TO L.O. SYSTEM YES NO PILOT BORED COMPLETELY MACHINED
REV. NO.

TERMINATION WITH FLANGED

CONNECTIONS AT RADIAL COUPLING BASE PLATE


PLANE YES NO
SIGHT FLOW INDICATOR IN EACH BASE PLATE OIL FIELD SKID
BY/DATE
OTHER

RETURN BRANCH MAKE MODEL SUPPLIED BY SULZER SAUDI PUMP COMPANY LIMITED
THRUST BEARING LOADS: TO ACCOMMODATE: DRIVER GEAR PUMP

MAX. ALLOWABLE AXIAL FORCE: N L.O. AND/OR S.O. SYSTEM MOUNTED ON BASE OFF BASE
DESIGN AXIAL FORCE: N DESIGNED FOR INSTALLATION ON:
CONCRETE FOUNDATION STEEL PLATFORM
OPERATIONS/DATE

LUBRICANTS DRILLED FOR DRIVER YES NO GEAR YES NO

BEARING LUBRICANT ISO GRADE 46 (Note M11) HORIZONTAL ALIGNMENT JACKSCREWS YES NO

OIL PER 26-SAMSS-088 GREASE PER 26-SAMSS-054


REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)

FLOW OR SUPPLY HEAT MAX. OIL MATERIALS OF CONSTRUCTION


CAPACITY PRESSURE REMOVAL OUTL. TP. MATERIALS TO BE IN ACC. WITH CODE HSI (Note M16)
O
GPM/USGAL PSIG BTU/MIN F OF STD. DRAWING AD-036821
CONST. AGENCY/DATE

INB. BRG. NA NA NA NA VENDOR TO COMPLETE FOLLOWING MAT'L LISTING

OUTB. BRG. NA NA NA NA / 1 CASING ASTM ASTM A351 Gr CF3M


THRUST BRG. NA NA NA NA 2 IMPELLER(S) ASTM ASTM A 743 CF3M
NA NA NA NA 3 CASE WEAR RINGS ASTM N/A
NA NA NA NA 4 IMPELLER WEAR RINGS ASTM N/A
TOTAL 5 SHAFT ASTM ASTM A 276 XM19
LUBE OIL SYSTEM SUPPLIED BY: PUMP VENDOR 6 SHAFT SLEEVES ASTM N/A
OTHER 7 THROAT BUSHINGS ASTM A276-S21800
CERTIFIED/DATE

IN ACCORDANCE WITH DATA SHEET FORM 8004-ENG 8 INTERSTAGE SLEEVES ASTM N/A
YES, DRAWING NO. NO 9 INTERSTAGE BUSHINGS ASTM N/A
DESIGN CERTIFICATION

10 LANTERN RING (PACKED PUMPS) ASTM NA


(DESIGN AGENCY)

11 GLAND / MECH. SEAL FLANGE ASTM In Seal Dwg


COOLING 12 BEARING BRACKETS ASTM A216 Gr. WCB
BEARING COOLING 13 1 NON-WETTED STUDS / NUTS ASTM A193 B7 / A194 2H
NON-CIRCULATING SYSTEM BY: 2 WETTED FASTENERS ASTM
ENGG./DATE

SHAFT MOUNTED FAN JACKETED BEARING HOUSING 14 PIPING: PIPE / FITTINGS ASTM A312 TP316L / A182 F316L

COILS IN BEARING HOUSING 15 BASE PLATE ASTM A 36


16 MECH. SEAL SPRINGS ASTM In Seal Dwg
EXTERNAL CIRCULATING SYSTEM 17 MECH. SEAL OTHER METAL PARTS ASTM In Seal Dwg
OIL COOLING BY: 18 ASTM
LIQ. PUMPED FOREIGN LIQ. AIR NONE 19 ASTM
STUFFING BOX COOLING YES NO

PEDESTAL COOLING YES NO NOISE SPECIFICATION


COOLING PIPING FOR REFER SHEET 11
IS COVERED, FOR ALL APPROVAL

AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER

BEARINGS STUF. BOX PEDESTALS SEAL COOLER

IN ACCORDANCE WITH API-610. FIG. D-4. PLAN MAXIMUM ALLOWABLE SOUND LEVEL

BY PURCHASER AT 3 FT. DISTANCE < 85 dBA


REVISION VALIDATION

COOLANT DATA MANUFACTURER GUARANTEED

BRG STUF PEDES- SEAL PUMP dBA


DRAWING COMPLETION CERTIFICATE NO.

HSG BOX TAL COOLER DRIVER dBA

TOTAL FLOW USGPM NA NA NA NA OTHER dBA

INLET PRESS. PSIG NA NA NA NA COMPLETE TRAIN 79 dBA


O
TEMP. INLET F NA NA NA NA
O
TEMP. OUTLET F NA NA NA NA
THIS REVISION NO.

COOLING MEDUIM NA NA NA NA

MECHANICAL DATA SHEET FOR MEG PIPELINE CORROSION INHIBITOR


DWG. TYPE UNLOADING
PLANT NO. PUMP
INDEX DRAWING NO. SHT.NO. REV.NO

T70-G-0008 A/B - MEG PL CORROSION INHIBITOR UNLOADING PUMPS


DAT
INLET FACILITIES - PACKAGE 9 T70 G CE-795877 4 B
TANAJIB SAUDI ARABIA
EKRD/2741-3-0915.XLS
SULZER CONFIDENTIAL
#
Saudi Aramco 2741-ENG (09/2015)

THIS REVISION IS NOT TO BE USED


SAUDI ARABIAN OIL COMPANY

FOR CONSTRUCTION UNTIL


CERTIFIED AND DATED
CENTRIFUGAL PUMP DATA SHEET FOR HORIZONTAL PUMPS AND VERTICAL IN-LINE PUMPS
NOTE: BY MANUFACTURER OF PUMPS PER ASME B 73.1 OR B 73.2

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
REVISION DESCRIPTION

INDICATES INFORMATION TO BE COMPLETED BY PURCHASER; BY MANUFACTURER OF PUMPS OR PUMPS PER 31-SAMSS-004


UTILITIES (Note M6) INSPECTION AND TESTS (Note M5)

OBSER'D
CERT'D
WITN'D

NONE
ELECTRIC POWER AVAILABLE VENDOR'S STANDARD SHOP TEST
AC PHASE AS FOLLOWS
VOLTS
DC HZ HYDROSTATIC TEST
MAIN ELECTRIC DRIVER AC 460 3 / 60 WATER KEROSENE
CONTROLS AND PROTECTION RUNNING TEST
PERFORMANCE TEST
BI-10-09003
DATE

AIR AVAILABLE MEASURE DP ACROSS STUFFING BOX


JOB ORDER/EWO NO.

PSIG NPSH TEST (Note M19)


CONTROLS AND PROTECTION DISMANTLING (Note M20)
RADIOGRAPHIC INSPECTION IMPELLER
REV. NO.

DYE PENETRANT EXAMINATION IMPELLER


AVAIL INLET OUTLET REQ'D DYNAMIC BALANCE IMPELLER(S)
PSIG O O O
AVAIL COOLING F F F DYNAMIC BALANCE ROTOR
WATER 80 102 130 DYNAMIC BALANCE COUPLING
BY/DATE
OTHER

VIBRATION, MEASUREMENTS
WELL WATER TREATED WATER SEA WATER TESTS TO BE CARRIED WITH:
ONCE THROUGH SYSTEM CLOSED LOOP SYSTEM ACTUAL DRIVER MANUFACTURER'S DRIVER (Note M21)
AT RATED SPEED DERATED SPEED: RPM
OPERATIONS/DATE

INSTRUMENTATION & CONTROLS


DRAWINGS AND OTHER DATA (Note M12)
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)

TEMPERATURE RADIAL THRUST CASING


MONITORING BEARINGS BEARINGS THERMOWELL MANUFACTURER'S DRAWING OR DOCUMENT

YES REQUIRED
PROVISIONS ONLY YES NO
DIMENSIONAL DRAWING OF
CONST. AGENCY/DATE

O
ALARM SETTING F COMPLETELY ASSEMBLED UNIT
O
SHUTDOWN SETTING F OPER. & MAINT. INSTRUCTIONS
CROSS SECT. DRW. WITH PART NO'S.
VIBRATION / DISPLACEMENT MONITORING MECHANICAL SEAL DRAWING
BILLS OF MATERIALS
POSITION RADIAL BRG'S THRUST BRG. BRG. HSG COMPLETED PUMP DATA SHEET
TYPE PROXIMITY PROXIMITY SEISMIC AUXILIARY PIPING DWG.
CERTIFIED TEST CURVE & DATA
YES RECOMMENDED SPARES LIST
PROVISIONS ONLY INSTR. WIRING DIAGRAM
CERTIFIED/DATE

SPEED TORQUE CURVE


ALARM / SHUTDOWN COLD ALIGNMENT CURVE
DESIGN CERTIFICATION

SETTING: MILS P-P / DATA L. & T. VIBR. ANALYSIS


(DESIGN AGENCY)

MILS P-P /
IN / SEC RMS /

SEISMIC PNEUMATIC MISCELLANEOUS


ELECTRICAL

PROXIMITY PAINTING
ENGG./DATE

SHAFT SEAL LEAKAGE CONTROL: YES NO


ELECTRICAL PNEUMATIC BUYER'S PAINT SPECIFICATION: SAES-H-001 / SAES-H-101V
/ PRES. SWITCH MAKE MODEL VENDOR'S STANDARD:
/ PRESSURE SETTING *SHUTDOWN* PSIG
LEVEL SWITCH MAKE MODEL
/ TIME DELAY SETTING CONTR.ORIFICE IN SPECIFICATION
AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER
IS COVERED, FOR ALL APPROVAL

MASSES PUMPS TO BE IN ACCORDANCE WITH:

31-SAMSS-004
/ PUMP LBS 243 ASME B 73.1 ASME B 73.2
REVISION VALIDATION

DRAWING COMPLETION CERTIFICATE NO.

PUMP ROTATING ASSEMBLY LBS 88 OR ISO 2858 & ISO 5199


CASING (UPPER HALF) LBS INCLUDED
BASEPLATE LBS 1653
COUPLING LBS 77
DRIVER LBS 178
DRIVER ROTATING ASSEMBLY LBS INCLUDED
TOTAL MASS LBS 2248
THIS REVISION NO.

MECHANICAL DATA SHEET FOR MEG PIPELINE CORROSIONDWG.


INHIBITOR
TYPE UNLOADING
PLANT NO. INDEXPUMP DRAWING NO. SHT.NO. REV.NO.

T70-G-0008 A/B - MEG PL CORROSION INHIBITOR UNLOADING PUMPS DAT

INLET FACILITIES - PACKAGE 9 T70 G CE-795877 5 B


TANAJIB SAUDI ARABIA
# SULZER CONFIDENTIAL EKRD/2741-4-0915.XLS
Saudi Aramco 2616-ENG (11/2010)

SAUDI ARABIAN OIL COMPANY

UNTIL CERTIFIED AND DATED


THIS REVISION IS NOT TO BE
USED FOR CONSTRUCTION
REVISION DESCRIPTION NOTES: (P-NOTES: BY PROCESS ; M-NOTES: BY MECHANICAL)

P1. PUMPING SYSTEM DESIGN PRESSURE / TEMPERATURE: 155 psig / 180 ºF. MDMT: 34ºF.

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
P2. APPLICABLE PFD & P&ID DOCUMENT NUMBERS ARE T70-A-PFD-CA-789871-002 & T70-A-PID-CA-789950-007 RESPECTIVELY

P3. REPORTED NPSHA APPLIES AT PUMP CENTRE LINE (ASSUMED AS 2.5 Ft) AND DOES NOT INCLUDE ANY MARGIN. VENDOR TO ENSURE
NPSHA EXCEEDS NPSH3 BY AT LEAST 3.28FT AT RATED FLOW.

P4. REPORTED NPSHa APPLIES AT PUMP CL (ASSUMED TO BE 2.5 FT) AND DOES NOT INCLUDE ANY MARGIN. VENDOR TO ENSURE NPSHA
EXCEEDS NPSH3. NO MARGIN IS REQUIRED WHEN CONSIDERING NPSH3 AT 120% OF RATED CAPACITY
DATE

BI-10-09003

P5. PUMP TURNDOWN IS NOT CONSIDERED AS THIS IS AN UNLOADING PUMP AND IN INTERMITTENT SERVICE.
JOB ORDER/EWO NO.

P6. 2 X 100 % PUMPS SHALL BE PROVIDED.


REV. NO.

P7 NO DESIGN MARGIN IS APPLIED TO THIS PUMP AS IT OPERATES IN INTERMITTENT SERVICE

P8 PUMP MOTOR TO BE DESIGNED FOR OPEN DISCHARGE VALVE.

P9. DELETED.
BY/DATE
OTHER

P10. DELETED.

P11. PUMPED FLUID IS CORROSION INHIBITOR. FLUID PROPERTIES TO BE CONFIRMED BY SUPPLIER.


OPERATIONS/DATE

P12. PUMP TO BE CONSIDERED AS FRICTION DOMINATED.

P13. MIN. FLOW TO BE CONSIDERED EQUAL TO NORMAL FLOW, AS THIS PUMP OPERATES IN INTERMITTENT SERVICE AT CONSTANT RATE.
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)

P14. PUMP SHUT-OFF HEAD SHALL NOT EXCEED 125% OF SPECIFIED DIFFERENTIAL HEAD AT RATED FLOW INCLUSIVE OF ALL API TOLERANCES

P15. FLUID PROPERTIES PROVIDED ARE AT 120 DEG F.


CONST. AGENCY/DATE

M1. MAXIMUM ALLOWABLE SOUND LEVEL FOR PUMP / MOTOR SET SHALL NOT EXCEED 85 dB(A) AT A DISTANCE OF 3.28 Ft.

M2. DELETED

M3. IN HAZARDOUS, FLAMABLE OR TOXIC SERVICE, MECHANICAL SEALS SHALL BE IN ACCORDANCE WITH 31-SAMSS-012.
CERTIFIED/DATE

M4. VENDOR SHALL REVIEW SEAL SELECTION MADE IN DATASHEET.


DESIGN CERTIFICATION

M5. TESTING SHALL BE AS PER 175-310500.


(DESIGN AGENCY)

M6. FOR SITE DATA AND UTILITIES REFER TO BEDD DOCUMENT NO.T80-A-DAT-CE-796542

M7. VENDOR TO COMPLETE ALL DATA FOR THE EQUIPMENT PROPOSED.


ENGG./DATE

M8. EQUIPMENT LOCATION WILL BE SUBJECTED TO DIRECT SUNLIGHT, HUMIDITY TO 100% AND SAND / DUST STORMS. I.E., HIGHLY
CORROSIVE ENVIRONMENT CLASSIFICATION (SEVERE FOR ELECTRICAL EQUIPMENT).

M9. MANUFACTURER STANDARD FOR EXTERNAL COATING IS ACCEPTABLE PROVIDED THAT VENDOR COATING IS SUITABLE FOR
ENVIRONMENTAL CONDITIONS OF THE SITE. AS A MINIMUM, THE COATING SYSTEM SHALL BE EQUIVALENT TO ISO 12944-5,
CORROSION CATEGORY C5-M HIGH DURABILITY FOR OFFSHORE (EQUIVALENT TO Cx IN ISO 12944-2:2017) AND C5-I
HIGH DURABILITY FOR ONSHORE (EQUIVALENT TO C5 IN ISO 12944-2:2017). THE PRIMER BINDER SHALL BE EPOXY OR ETHYL
SILICATE EXCEPT WHERE ALTERNATOVES ARE APPROVED FOR HIGH TEMPERATURES.
THE VENDOR’S PAINTING PROCEDURES SHALL BE ISSUED FOR CONTRACTOR/COMPANY REVIEW AND APPROVAL.
IS COVERED, FOR ALL APPROVAL

AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER

STAINLESS STEEL SHALL BE PAINTED IN ACCORDANCE WITH SAES-H-001 - SYSTEM APCS-1B UP TO 248°F OR APCS-11C
FOR HIGHER TEMPERATURES.
GALVANISED CARBON STEELS SHALL BE PAINTED IN ACCORDANCE WITH SAES-H-001.
REVISION VALIDATION

M10. PUMPS SHALL BE DESIGNED FOR A MINIMUM SUSPENDED SOLIDS OF 0.03% (300 PPM) BY WEIGHT.
DRAWING COMPLETION CERTIFICATE NO.

ACCORDING TO SECTION 4.1.1.11 OF SAES-G-005

M11. ISO GRADE 46 OIL SHALL BE USED FOR BEARING LUBRICATION.

M12. DOCUMENTS AND DATA SHALL BE AS PER NMR SA 7902.


THIS REVISION NO.

MECHANICAL DATA SHEET FOR MEG PIPELINE CORROSIONDWG.


INHIBITOR
TYPE UNLOADING
PLANT NO. PUMP
INDEX DRAWING NO. SHT.NO REV.NO.

T70-G-0008 A/B - MEG PL CORROSION INHIBITOR UNLOADING PUMPSDAT

INLET FACILITIES - PACKAGE 9 T70 G CE-795877 6 B


TANAJIB SAUDI ARABIA
EKRD/2616-1110.XLS
# SULZER CONFIDENTIAL
Saudi Aramco 2616-ENG (11/2010)

SAUDI ARABIAN OIL COMPANY

UNTIL CERTIFIED AND DATED


THIS REVISION IS NOT TO BE
USED FOR CONSTRUCTION
REVISION DESCRIPTION NOTES: (P-NOTES: BY PROCESS ; M-NOTES: BY MECHANICAL)

M13. DELETED.

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
M14. DELETED.

M15. DELETED.

M16. SS 316 L REQUIRED FOR THIS SERVICE. PMI CHECK IS REQUIRED FOR PUMP ALLOY COMPONENTS.

M18. HAZARDOUS AREA CLASIFFICATION IS: CLASS 1, ZONE 2, GROUP IIA/IIB, CLASS T3.
DATE

BI-10-09003

M19. NPSH TESTING IS REQUIRED ON ALL IDENTICAL PUMPS WHEN MARGIN BETWEEN NPSHA AND NPSH3 IS LESS THAN 3.3 FEET
JOB ORDER/EWO NO.

AT 120% OF THE RATED FLOW. OTHERWISE ONLY ONE PUMP REQUIRES NPSH TESTING

M20. PUMP SHALL BE DISMANTLED TO INVESTIGATE THE CAUSE OF ANY UNSATISFACTORY PERFORMANCE, NPSH, OR RUNNING TESTS
REV. NO.

M21. TEST SHALL BE PERFORMED WITH CALIBRATED DRIVERS


BY/DATE
OTHER

OPERATIONS/DATE
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)
CONST. AGENCY/DATE
CERTIFIED/DATE
DESIGN CERTIFICATION
(DESIGN AGENCY)
ENGG./DATE
IS COVERED, FOR ALL APPROVAL

AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER


REVISION VALIDATION

DRAWING COMPLETION CERTIFICATE NO.


THIS REVISION NO.

MECHANICAL DATA SHEET FOR MEG PIPELINE CORROSION INHIBITOR


DWG.UNLOADING
TYPE PUMP
PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.

T70-G-0008 A/B - MEG PL CORROSION INHIBITOR UNLOADING PUMPSDAT

INLET FACILITIES - PACKAGE 9 T70 G CE-795877 7 B


TANAJIB SAUDI ARABIA