Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

OTDR report

Job info
Job ID : Reason :
Contractor : NOVKER Operator A :
Customer : Operator B :
Test date : 10-Nov-19 (9:07:52 AM GMT+7:00) File : Kabel eks1 C1-1550.sor

Cable info
Fiber ID : Cable ID :
Location A : Location B :
Cable mfr. : Type :
Subset ID : Color ID :

Link measurements
Span loss : 2.723 dB Avg. splice loss : 0.144 dB
Span length : 11.2752 km Max. splice loss : 0.296 dB
Average loss : 0.241 dB/km Span ORL : <30.82 dB

OTDR trace

dB

25.00

20.00
1

2
15.00 34
5

10.00
6

5.00

0.00
5 10 15 20 25 30 km

Signature : _________________________ Date : 12-Dec-19


EXFO E. O. Engineering Inc. Page 1 / 2
OTDR report
Events table
No. Loc. Event type Loss Refl. Att. Cumul.
(km) (dB) (dB) (dB/km) (dB)

1 0.0000 Launch Level 0.000 0.000


Fiber Section (3.0368 km) 0.550 0.181 0.550
2 3.0368 Non-Reflective Fault 0.242 0.792
Fiber Section (2.7427 km) 0.540 0.197 1.332
3 5.7795 Non-Reflective Fault 0.146 1.478
Fiber Section (0.2144 km) 0.099 0.460 1.577
4 5.9940 Non-Reflective Fault 0.296 1.873
Fiber Section (1.2662 km) 0.215 0.170 2.088
5 7.2601 Non-Reflective Fault -0.108 1.980
Fiber Section (4.0150 km) 0.743 0.185 2.723
6 11.2752 Reflective Fault 0.000 66.3 2.723

Marker info
A : 0.0000 km, 0.000 dB B : 0.0000 km, 0.000 dB
a : 0.0000 km, 0.000 dB b : 0.0000 km, 0.000 dB
A to B distance : 0.0000 km, 0.000 dB A to B ORL : *****
3-pt. reflectance : ***** A to B LSA att. : -0.000 dB/km
4-pt. Ev. loss : 0.000 dB

Test and cable setup


Wavelength : 1550 nm (SM-9µm) Acq. time : 10 s
Filename : Kabel eks1 C1-1550.sor Pulse width : 500 ns
Hardware : Helix factor : 0.00 %
Serial number : Splice loss threshold : 0.100 dB
Software : N/A Reflectance threshold : -40.0 dB
Range : 33.4600 km End-of-fiber threshold : 10.000 dB
IOR : 1.468000
RBS : -80.00

Signature : _________________________ Date : 12-Dec-19