Brebes N TO N PJG C2

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

OTDR report

Job info
Job ID : Reason :
Contractor : NOVKER Operator A :
Customer : Operator B :
Test date : 10-Nov-19 (8:38:23 AM GMT+7:00) File : N TO N PJG C2-1550.sor

Cable info
Fiber ID : Cable ID :
Location A : Location B :
Cable mfr. : Type :
Subset ID : Color ID :

Link measurements
Span loss : 2.634 dB Avg. splice loss : 0.359 dB
Span length : 11.4140 km Max. splice loss : 0.405 dB
Average loss : 0.231 dB/km Span ORL : <30.66 dB

OTDR trace

dB

25.00

20.00
1

2
15.00 3
4

10.00

5.00

0.00
5 10 15 20 25 30 km

Signature : _________________________ Date : 12-Dec-19


EXFO E. O. Engineering Inc. Page 1 / 2
OTDR report
Events table
No. Loc. Event type Loss Refl. Att. Cumul.
(km) (dB) (dB) (dB/km) (dB)

1 0.0000 Launch Level 0.000 0.000


Fiber Section (3.1450 km) 0.500 0.159 0.500
2 3.1450 Non-Reflective Fault 0.313 0.813
Fiber Section (2.7325 km) 0.519 0.190 1.332
3 5.8775 Non-Reflective Fault 0.405 1.737
Fiber Section (5.5365 km) 0.897 0.162 2.634
4 11.4140 Reflective Fault 0.000 63.0 2.634

Marker info
A : 0.0020 km, 12.652 dB B : 0.0041 km, 23.701 dB
a : 0.0000 km, 0.000 dB b : 0.0061 km, 23.701 dB
A to B distance : 0.0020 km, -11.049 dB A to B ORL : *****
3-pt. reflectance : -42.8 dB A to B LSA att. : -5410.252 dB/km
4-pt. Ev. loss : -23.701 dB

Test and cable setup


Wavelength : 1550 nm (SM-9µm) Acq. time : 10 s
Filename : N TO N PJG C2-1550.sor Pulse width : 500 ns
Hardware : Helix factor : 0.00 %
Serial number : Splice loss threshold : 0.100 dB
Software : N/A Reflectance threshold : -40.0 dB
Range : 33.4600 km End-of-fiber threshold : 10.000 dB
IOR : 1.468000
RBS : -80.00

Signature : _________________________ Date : 12-Dec-19


EXFO E. O. Engineering Inc. Page 2 / 2