Professional Documents
Culture Documents
Chapter 3 - Maintenance Management
Chapter 3 - Maintenance Management
Chapter 3 - Maintenance Management
Presented by
Amir Farid Omar
09 DECEMBER 2018
Content
• INTRODUCTION
• THE MAINTENANCE POLICY & STRATEGY
• MAINTENANCE METHODS & PLANNING
• PERMITS AND APPROVALS
• INSPECTIONS
• BUILDING SERVICES ENGINEERING INSTALLATIONS
• MANUALS, REGISTERS AND INVENTORIES
• MAINTENANCE MANUALS
INTRODUCTION TO MAINTENANCE
First, some questions
1 What is maintenance?
2 Why is maintenance done?
3 What happens if we don’t do
maintenance?
Definition
Maintenance
: the upkeep of property or equipment – Merriam Webster
Scheduling
: to appoint, assign, or designate for a fixed time – Merriam Webster
: a list of planned activities or things to be done showing the times or dates when
they are intended to happen or be done - Cambridge
Definition
Other definitions (from IFMA):-
Planned Unplanned
Preventive Corrective
Periodic Emergency
Cyclic Breakdown
Proactive Reactive
Why is maintenance required?
•to preserve assets
If one asks the
•for business to continue
‘Management’
•to comply with regulations
level…
Movement/drift •••Common
Applicable
Airborneitems
also are
dust and
to
electronics
glands, seals, bearings,
particles necessitates
•contactors,
maintenance,
Contributes fluidse.g. filters
towards
Environment •‘looseness’
Certain equipment
•••Cleaning
Also partsisthat
Condensation necessary
come
also a for
into
generates waste or by-
certain
•contact
factor
Fatigue,items
with heat
vibration andto
products that needs
Waste creation friction
••Also necessary
be removed to
Corrosion, erosion,
‘control’
scaling, the environment
chemical
• Examples are like cooling
Cleaning the equipment is in
towers
Why do things break down?
Human Related Not Human Related
(CONTROLLABLE) (UNCONTROLLABLE)
Neglect
Abuse
Mal-operation
Sabotage
Unscheduled maintenance costs
Part/component Hire backup
repair/replace equipment
SHE/insurance
Revenue/penalty premium
MAINTENANCE STRATEGY
WHAT IS MAINTENANCE POLICY
is a set of administrative, technical and managerial actions to apply
during the life cycle of a equipment, used to guide maintenance
management decision making towards retaining certain operation
conditions of a machine or dedicated to restoring the machine to said
conditions
Maintenance Strategy
Unscheduled Scheduled Maintenance
2 Corrective Maintenance
5 Operation Activities
Best Maintenance Practices
Identify Asset/Sub-Assets
Step 2 : Carry Out Equipment Create & Test Asset Codes
Label Assets/Sub-Assets
Audit Update Database
Estimate availability
Step 3 : Carry Out Reliability & Estimate reliability
Criticality Audit Analysis –FMECA.FMEA,etc
Maintenance history
Setting Up Maintenance Program
Condition Based Monitoring
Step 4: Select Appropriate Inspection Task
Maintenance Strategy/Task Preventive Maintenance
Corrective Maintenance
Review
Step 7 Operations
Step 4,5
Monitor KPI
Step 6
MAINTENANCE METHODS & PLANNING
Planned Preventive Maintenance
Maintenance performed over fixed intervals
3
The required staff qualifications and skills, which can
be gained through training.
PPM requirement
The factors that affect the efficiency of this type of
maintenance:
PM Work
Order Closing Corrective Yes
Comply? Need
Action
Yes No Repair?
No
Verification of Check and Monitoring
work done Test Run
Corrective
Record Maintenance
Keeping Works
PM Checklist Example
PPM SOP & Checklist
•What is SOP?
1. Fault detection.
2. Fault isolation.
3. Fault elimination.
4. Verification of fault elimination.
Verification of repair.
Predictive Maintenance (PdM)
Predictive maintenance is a set of activities that detect
changes in the physical condition of equipment (signs of
failure) in order to carry out the appropriate maintenance
work for maximising the service life of equipment without
increasing the risk of failure.
Thermography
Vibration Monitoring
Oil Analysis
Ultrasound/Acoustic
Inspections
Vibration Monitoring
• Determining equipment condition via analysis
of vibration
• Requires equipment that can generate Fast
Fourier Transform (FFT) spectrum
• Data analysis required to diagnose
• Good for rotating equipment (non
reciprocating). Generally not for hydraulic
systems
Vibration Monitoring
Vibration Monitoring
General parameters observed
Imbalance
Misalignment
Shaft/bearing status
Mechanical looseness
Misalignment example
Vibration levels – a guide
Vibration Reading Severity Level Action Needed
(mm/sec)
worsening
7.6 to 15.1 Alarm Determine cause and
take action
Moisture/cold
area detection
Ultrasound/Acoustic Monitoring
•Detection of problem
areas by noise
•Some equipment can
translate inaudible sound
to audible
•Also for leak detection
•Trained personnel
required Electronic stethoscope
Oil Analysis
• Method of determining equipment health by analysis
of lubricant
• Mostly a chemical process and requires a laboratory
or purchase of expensive equipment
• Periodic sampling is required
• Trending provides insight on equipment state
• Primarily used for equipment with large oil sumps
(lube, hydraulic, reciprocating eqpt, etc)
Oil Analysis – Principles
3 main areas
73
OBJECTIVE
▪ To highlight discrepancies
74
FCA PROCESS
75
The condition assessment
METHOD OF ASSESSMENT AND INFORMATION GATHERING
76
Facility Condition Audit – Methodology
Deployment of our audit team to gather data &
information related to the facility
77
Method of Identifying Building Damages
• Walk-About inspections
• Building Surveying exercise
• Technical Testing on specific
equipment/building structure
78
Facility Condition Audit – Audit Requirement
▪ Liaison Officer throughout the Audit
79
Facility Condition Audit – Scope of Audit
Typical Scope of Services Customisable for the Audit:
▪ Documentation Audit
80
Evaluation Criteria
1 EXCELLENT
A facility with risk assessment to the
defects less than 25%
< 25%
5 Very Poor
A facility with risk assessment to the
defects more than 75%
75%
Facility Condition Audit – Critical Success Factor
83
Facility Condition Audit – Sample Report
Report Contents
84
4.0 Facility Condition Assessment
Sample Report
85
Facility Condition Audit – Sample Report
▪
Detailed Findings
Category A
Location: Ground Floor – Podium/ Mall
MECH-0415
Evaluation Item: Passenger Lift (Glass Lift)
Observation: 1 unit lift was found not functioning due to the failure of landing door contact
and PMA is not available.
Defect Category: A
▪ Category B
Location: Level 1 – MSB Room (Sharing)
MECH-0415
Evaluation Item: CO2 Panel
Defect Category: B
86
Summary of Approaches to Maintenance
Unscheduled Scheduled Maintenance
Similarly in any other country, certain laws, regulations and statutes are relevant for the facility
management industry.
An Act is a bill that has been passed by both houses of the parliament, or a legislative body. An
ordinance is a legal order made by a local council or state.
➢ Uniform Building By-Laws 1984 - It comprises a set of rules that specify the minimum
acceptable level of safety for constructed objects such as building and non-building structures.
90
➢ Occupational Safety and Health Act 514, 1994 - Legislation was made
considering the fact that the Factory and Machinery Act 1967 only covers
occupational safety and health in the manufacturing, mining, quarrying
and construction industries, whereas the other industries are not covered.
➢ Factories and Machinery Act 139, 1967 - Provides control with respect to
matters relating to the safety, health and welfare of persons in their
working spaces as well as the registration and inspection of applicable
machinery.
91
➢ Fire Services Act 341, 1988 - Provision for the effective and efficient
functioning of the Fire Services Department, for the protection of persons
and property from fire risks and for purposes connected therewith.
➢ Street Drainage and Building Act 133, 1974 - Covers the maintenance
and repair of public streets and buildings including aspects such as
regulating the naming, numbering, signs and related services such as fire
hydrants etc. The act also regulates and clarifies the need for proper drainage
system and associated penalties.
➢ Water Services Industry Act 655, 2006 - This act deals with the licensees
in the provision public water supply. Matters relating to safety, maintenance
and other obligations are also addressed.
92
➢ Sewerage Services Act 508, 1993 - Consolidates the laws relating to
sewerage systems and sewerage services for the purpose of improving
sanitation, the environment as well as promoting public health.
➢ Gas Supply Act 501, 1993 - Provides for the licensing of the supply of gas
to consumers via pipelines, the prices, control of gas pipelines and
installations relating to safety.
It also specifies that only competent persons are allowed to maintain the gas
supply equipment.
93
Role and Function of Relevant Authority
Fire and Rescue Department (Bomba)
Energy Commission
The Energy Commission (Suruhanjaya Tenaga, ST) is the regulator for the
electricity and gas supply industry entrusted with powers provided in the
Energy Commission Act 2001 and the other related Acts
❖Economic Regulation
❖Technical Regulation
❖Safety Regulation
96
Application Procedures and Requirements
In FM, the main responsibility in the early stage of providing services is to
check the availability of the certificates for the relevant plant and machinery
for a particular site.
97
98
Tuan,
Merujuk kepada perkara diatas, kami ingin memaklumkan kepada pihak tuan bahawa perakuan kelayakan mesin angkat
yang bernombor pendaftaran seperti tertera diatas di bangunan kami sudah tamat tempoh pada ______hb______2011.
Oleh yang demikian, kami berharap pihak tuan akan membuat persediaan yang diperlukan untuk pembaharuan perakuan
kelayakan berkenaan. Bersama ini disertakan salinan sijil perakuan kelayakan mesin angkat berkenaan untuk rujukan pihak
tuan.
Yang benar,
(Nama Syarikat)
Regulation & Standards
Tenaga Nasional Bhd (TNB)
Jabatan Bomba Dan Penyelamat (JBPM)
Lembaga Air Perak (LAP)
Jabatan Kesihatan & Keselamatan Pekerja (JKKP)
Uniform Building By Law
Uniform Building By-Laws 1984
Fire Mode Operation and Smoke Control (AS 1668 Part 1 – Fire
Precaution in Building with Air Handling System)
National Fire Protection Associated (NFPA 12) and BS5306 Part 4 for
gas type extinguishing system.
Nasional Fire Protection Association (NFPA2001) for clean agent for
electronic-sensitive room
B.S 5306 : Part 1 and BS (EN) 671 : hydraulic Hose Reels System
B.S 5306 : Part 2 : 1990 and The Loss Prevention Council Rules for
Automatic Sprinkler Installations.
B.S 5839 Part 1,2,3 & 4 and EN 54 for Automatic Fire Detection and
Alarm system
B.S 5306 Part 3 for fire extinguisher
NFPA 96 and 17A for Wet Chemical System
BUILDING SERVICES ENGINEERING
INSTALLATIONS
ELECTRICAL INSTALLATION SYSTEM
The electrical system and services
Pentadbiran
Blok
Dewan Makan
Akademik
Library
Keselamatan
Surau
Dewan Makan
Pusat Pelajar
Keselamatan Asrama
FIRE ALARM SCHEMATIC
Hosereel System
Hosereel System
Structured
Efficient
Comprehensive
Faster
module
• Retrieval and updating of room or space datasheet, room reservation
Space Management management & infra
• Data display includes rooms finishes, assets, and utilities.
module
g. Space Tagging
• Signage/Sticker
Ciri-ciri Penomboran
SPACE MANAGEMENT MODULES
Q 03 01 A 01 001 /0
Menunjukkan Simpanan
Nombor Pecahan
Menunjukkan
Nombor Bilik
Menunjukkan Aras
Menunjukkan Blok
Evaluate of WR against No
Scope of Works.
Customer will be given a
Work Request (WR) Ref. Inform requestor
No.
Yes