GuideGuideGuideGuide
Page 2 / 51
Calculate
BasicSkills Plant Self-Assessment
Plant name :
Score
Excellence
Operational objective: safe operations, run according to Lafarge recommandations and best practices, in collaboration with other plant departments and
well documentated.
Some drillings with chemical data is Drilling and geological data are A block model not older than five
Geological data are missing. There
existing but not complete. available but not fully updated. years is based on reliable drill data
Data about long term is no reliable drilling campaign and
Geological studies are partly Topography is done. The block and geological information. It is used
reserves / Block model topography. Chemical data are too
existing. Block model is not reliable model can be used but is not very regularly. Topography is not older
doubtfull to build a block model.
because of missing/doubtfull data. accurate. than 1 year.
P1
A drilling protocole is systematically
There are well-defined practices
procedure. There is no optimisation small number of criterias. There is requirements & costs, cost effective
Equipment selection reliability (RF>= 86, 87) Equipment
to minimize downtime and to no formal studies to help select the repair strategy and after-sale
is choosen taking into account rock
lengthen equipment life. equipment. service, life expectancy, re-sale
properties, capacity and size for
value) and that you could share with
output material according to the
other plants.
Quality Control plan.
All
Choose the appropriate No stock pile logic defined in Regular checks are run to control
unformal way, subcontractors are crusher and prehomo piles is
PROPORTIONING
method for pile common in anticipation, no control the adequate proportioning and
not involved, few controls are run adjusted according to complexity (1
All
P1
Guidelines and procedures for
The capacity of equipment is no Best practices for each equipment Best practices and guidelines per
efficient blending versus equipment
Mgrs
adjusted to the need and/or Best are known but not completely equipment are used. Most of the
Benchs are not completely Full protection from the crest of the
Benchs are not securised and securised and maintenance of roads bench. Roads and sign roads Local legislations or documentations
Road construction and maintenance is done from time to is not very regularly done. (speed limits) are constantly are systematically applied and all
conditions time. Recommandations are not Recommandations of the maintened. Recommandations of recommandations of the Geo. Guide
applied. Geomining Guide are known but not the Geo. Guide are respected and too.
always applied. local legislation is applied.
Stakeholders Noise is not monitored or there are Some actions are done to reduce Detonating cords are avoided or
conveyors for full compliance with
relationships/ Noise complaints from stakeholders. noice but not systematically. covered if you have to use them.
legislation and good stakeholders
Closest neighbours are informed
relationships.
about blast campaigns.
P1
Rehabilitation plan is partly The Lafarge rehabilitation policy as
A rehabilitation plan which takes into
Mgrs
There is no formalised rehabilitation formalized but local legislations and explained in SQRP and Geomining
composition.
Chemical analysis of drilling cutting
Continuous corrections are done
Loading and feeding are not done Some chemical analysis are done are sufficient to be representative for
Quality Control of according precise chemical analysis
according to the composition of the and give indications for loading and the blast material. These analyses
blasted material to optimize the quality and regularity
blast material. feeding but they are approximative. define loading sequences and feed
of the crusher feed.
to crusher.
The QC plan is in line with the Compoptim or a similar mix
Quality Control plan exist but is not
QC in feed to the There is no formalized Quality blending rules and the composition calculation tool is used to set targets
fully applied. It is updated only from
crusher Control plan dedicated to this point. specifications, is rigurously applied for composition of material after the
time to time.
and regularly updated. crusher
Your block model and geological deposit, property limits, mining rights
Block model doesn't exist or is not A block model is generated and up-
data are not complete enough to and methods, transportation and
Long term mining plan usefull. Guidelines for future dated every 5 years, with support
have a good vision of your long term crushing system, reclamation plan
exploitation are not defined. from Technical Center specialists.
exploitation. and cost, clinker quality and cost
Engineers/ Managers
for the calculation and but it is not a rule. Simulation tools about the calculation results, key-
tools. Several of them are used used. Simulations are regularly
common tools for are used from time to time. functions are fully aware of the
giving slightly different results. done.
optimisation standard tools and documentation.
products.
Identify the main drivers They are identified thanks to Level C + potential risks have been
Documents with best and worse
(plant specific) for They are not identified. rigourous studies run jointly by all identified: what can happen in
scenarios have been written.
optimisation departments process with new tests, products?
1/2
You have an approximative idea on You have procedures for Risk management is included in the
Anticipate impacts on
All
There is no anticipation. fineness impacts but you haven't acceptance of raw material to avoid procedure and control chart has
fineness
formalized them. problem linked to fineness. been implemented.
IMPACTS ON PRODUCTION
Analyse emission impacts Some analysis are run but only in You try constinuously to reduce
There are regular emission control
All
(checked with legal There is no precise analysis. case of major incident (in particular if emission impacts (even though you
charts and environmental reports.
constrains) there no strong legal constrains) respect legal constrains).
impacts lead to new instructions for before burning but after, in case of external laboratory and control chart experts are done when necessary.
operations incident for parameter which influence the
burnability is implemented.
IMPACT
There is some procedures but there
Procedures for checking You have implemented a control
is no systematic control of You have procedure to check your
All and maintain reliability of loop to improve continuously
There is no procedure. equipment. Ponctual actions are raw mix about sampling system
dosing, testing and reliability of dosing, testing and
done to correct errors. There is no (accurate dosing).
mixing equipment mixing.
real improvement approach.
Storage capacity and You have an approximative idea on There is a calibration sheet, a Storage is optimized. Specific
IMPACTS ON PRODUCTION
Tech
logistic management They is no precise anticipation storage situation but you don't delivery and storage plan so that the solutions heve been implemented to
related to (silos, about the storage of raw materials. formalized logistical aspects linked material is in right amount, in right improve the storage conditions
deposit…) to it. time and in right place. according local conditions.
handling of raw materials/ between Quality and Production systematically taken to optimise
Quality on that point. Nothing is is written about the fluctuation of kiln
raw meal. teams. A short report is written. homogeneisation and handling.
formalized. feed & raw mix composition
checking the compliance to targets.
enough to efficiently adjust control chart is implemented to according to the temperature profile
alkalies ratio, liquid complete. They are erratic.
production factors . adjust production factors. (t°, lenght of burning zone).
phase)
modulis/drivers to control and only few indications are given to pertinent calculation and be able to
raw mix. Information given to what has the biggest influrnce on
the clinker quality the production team. give the best indications to the
production team could be more your process.
production team.
useful.
Establish corrective You use statistical tools but and documentation of actions for of actions are formalized to improve
Statistics skills are missing. Trend
Mgr
actions thanks to corrective actions are not systematic quick corrective actions with a reactivity of production team and
analysis are not run.
statistical control tools or badly communicated. shorter range than daily. They use consequently the efficiency of
control charts. corrective actions.
Some corrective actions are run but Procedures are formalized including
Set points, targets and There is no specific procedure if
you don't formalize a complete time schedule and techical center You have implemented a continuous
Mgr
plan actions if they are targets for raw mix quality are not
action plan. Targets are not up- reports are used (feasability, simix improvement process.
not reached reached, or they are not applied.
2/2
dated document…).
corrections.
Raw mix line compliance Local laws and legal affairs are not Local laws are known and legal Local laws are mastered and evolution concerning raw mix and
with local laws a major issue at the plant level. affairs are followed. communicated to concerned teams. preventive actions to avoid legal
problems.
Basic Skills Self-Assessment Grid
Operate with stable stable conditions but do not follow load, clinker cooler bed depth, hood systematically detected and
Operators are not able to maintain
conditions and optimize operating guidelines aimed at pressure, oxygen, calcination, ID fan analysed. Control charts and
stable conditions (kiln cycling).
KILN OPERATIONS
performance. maximizing production and meeting outlet pressure, free lime). Incidents procedures are regularly reviewed
quality targets. are analysed during reliability and improved accordingly.
meetings. Procedures and charts
are available.
air, hot spots, build-ups, Routine inspections are made, but Regular inspections are made, and Detailed checklists are used and
spillages, leakages, flap There are no routine inspections. observations are not recorded and inspection routes are defined. work orders are automatically
condition, vibrations, noices, checklists are not formalized. Checklists are available and used. generated.
dedusting system, etc.)
1/3
internally: all measurements, technical references on the full kiln
Engineer
Process incident Operators can only solve incidents equipment back to target range in
to an update of procedures /
management (hot spots, Nobody is able to solve incidents with the help of management. There optimal time by using available tools
recommandation trees. Operators
cyclone blockages, rings, without the help of TC. are no procedures or tools to help like BP, Les Cas. Procedures /
are trained to solve incidents on a
build ups) them. recommandation trees are available
kiln simultor.
in the plant.
There is an SOP for emergency
shutdown (power failure, PLC
Operators are able to implement the
Operators Operators are able to manage an failure, electrical distribution failure)
SOP in case of emergency
Emergency procedures and cooling emergency shutdown, but there is in order to secure equipment. There
Controlled and emergency shutdown without external help (e.g.
procedures are not followed and not no written procedure. Cooling are cooling procedures including
shutdown they have sufficient electrical
formalized. program is followed but not turning schedule and temperature
background/training, know how to
formalized by a written document. curve for kiln, cooler grate
reboot the PLC).
protection, burner pipe protection, ID
fans.
Routine inspections
There are routine inspections but There are regular inspections, and Detailed checklists are used and
(spillages, leakages, weigh
There are no routine inspections. observations are not recorded and inspections routes are defined. work orders are automatically
feeder cleanliness, belt
checklists are not formalized. Checklists are available and used. generated.
tracking, etc)
Shutdown inspections
(liners, diaphragms, There are regular inspections and
Operators
2/3
The annual mill audit is done
completely internally: all tests, The TC is only consulted for
inspections, calibrations, analyses of technical references concerning the
Engineer
Audits are done but the plant needs trends and flow sheets, reporting, triennial mill audit; otherwise, all
Audits (annual and Audits are not regularly done and/or
external help to perform them (even etc (as per the BP "Ball mill analyses and evaluations are
triennial) are not performed by the plant team.
for short, annual mill audit). optimisation and performance") are mastered at plant level. Audit follow-
performed and mastered by the up has already led to significant
plant team. The triennial mill audit is improvements at the plant.
done with help from TC.
Test results are properly translated
All operators & technicians
Translation of test results into into operational parameters. Even if
understand perfectly the link
Take appropriate corrective operational parameters is under expert software is usually used for
Operators
between tests results and
actions for kiln or mill Corrective actions for kiln or mill control only if an expert software corrective actions (QMC, Lucie),
operations (eg: if blaine too high,
operations based on results operations are not appropriate and system (QMC, Lucie) is in use. operators are able to react
what action should be taken on
(feeders, separator speed, are not under control. Some tools exist for calculation and appropriately in case of sofware
separator and why?), and they are
QUALITY
etc.) decision making (charts, tables), but breakdown by using calculation and
involved in Quality Management
they are not always used. decision making tools (charts,
System.
tables, decision tree).
Use of alternative fuels is planned in The plant can use any kind of fuel,
Alternative fuels are regularly and
Fuels management (relevant Alternative fuels are used without advance in the production plan. Raw as per the ressource recovery lever.
properly dosed; some raw mix
MANAGE
Regulations on emissions are not and emissions are monitored, but Emissions are fully controlled. There Specific tools or management
Emissions management
All
really considered. Emissions are not the plant doesn't yet comply with is a real commitment within the plant systems have been implemented to
S
Safety pep talk There are no safety pep talks. to time (for example in case of each shift. All recommandations/
3/3
responds to requests and chooses
incident). remarks are written down in a
points to be mentionned at the
dedicated notebook.
monthly safety meeting.
Basic Skills Self-Assessment Grid
Operational objective: properly conduct all major operations to guarantee constant flow and prevent most blockages under the safest conditions
Spillage is usually detected and monitored continuously. Transport Precise criteria have been
Transport equipment (belts, equipment pressure levels are equipment is inspected by production determined at plant level to identify
chain-supported, air, elevators, Spillage is not usually detected. checked from time to time. and maintenance teams on a when cleaning is necessary.
drag chains) Procedures do not exist or are not scheduled basis to avoid spillages Continuous improvement process is
applied. (belt alignment, belt cleaning device, implemented to minimize spillages.
bucket elevators recycling, etc).
There is no risk analysis done at risk analysis is done, taking into All the concerned persons are
Some risk analyses are performed
plant level. Risks associated with account specific risks such as involved in the risk analysis.
Risk analysis but not systematically and/or all risks
certain cleaning devices are not temperature, burying, suffocation, Significant actions have already been
are not taken into account.
precisely known. falls, dust inhalation, electrical injury, taken to reduce the identified risks.
reduced visibility.
WORK PREPARATION
Prevention plan There is no prevention plan. reduce them. All concerned before admission to the plant and
all risks are analysed and/or are not
operators are systematically briefed they involved in the prevention plan.
fully communicated to operators.
on potential hazards, receive safety
training and have regular medical
checkups.
Safe work permit Safe work permits are not delivered. not systematically and/or they are not before any intervention and signed
also specifc requirements, air
complete. by the responsible person and the
monitoring, emergency numbers, etc.
concerned operators.
WORK PREPARATION
All unnecessary equipment is
removed and protection installed to
prevent fires due to spillage of hot
materials. Suitable work platforms
Procedures exist and are applied, but are installed according to After each operation a debriefing is
Critical areas are not fully secured.
some hazardous points remain within procedures. Access to equipment is organised in view of improved
All
Cleaning plan for regular A schedule exists but does not take A cleaning plan exists and is The frequency of cleaning operations
Mgrs
in pre-heaters are executed without regular basis, but procedures are describing the operations and safety Root cause analysis involving
Pre-heaters (cyclone written procedures, and only from only partly written. Cyclone risks. All actions mentionned in the operators is carried out for all near
blockages) time to time. Cyclone blockages are blockages are cleared according the BP "Clearing Cyclone Blockages" misses. Safety procedures and
not cleared according the BP BP "Clearing cyclone Blockages" but (part 9, page 7) are taken for every training are adjusted accordingly.
"Clearing cyclone Blockages". there are no adapted procedures operation of blockage clearance, and
available in the plant. are included in procedures available
in the plant.
Release to production production once the cleaning is always formalised by a written (door closed, dampers, guards are in
formally defined in a procedure.
finished. document. All aspects are not always place) and before tests of the
communicated. installation. All useful information is
systematically communicated.
Basic Skills Self-Assessment Grid
Identification of a The need is formally identified but it The need is formally identified and
All
The largest contracted works are All the subcontracted works are
Definition of subcontracted works is defined through a specification that systematically defined through a
Specification of the The subcontracted work is not incomplete. There is no information includes technical conditions, specification that includes technical
All
service/supply formally defined. to the subcontractor about risks deadlines, works quality, risk conditions, deadlines, works quality,
analysis and safety. analysis and contractor's obligations risk analysis and contractor's
in terms of safety. obligations in terms of safety.
1/2
Before starting the work all the
Formal communication
Contractors' workers sometimes contractors' workers receive
about plant All the contractors' workers receive
Contractors' workers do not receive receive individualized individualized communication on
All
contractors' workers.
of this training.
2/2
Purchasing closes the requests with finished by the subcontractor and
Purchasing closes the requests
Mgrs
Substations : equipment
There is a formalised monthly Every three years a thermographical
condition (lighting,
inspection to check medium and low analysis is done and equipment is
Technicians
ventilation, pressurisation,
voltage equipment. Work orders are controlled by constructor. Every
filtration, air conditionning, There is regular inspection, but it is
used and include a formal checklist. intervention is recorded. Fire
cleanliness, locked access, They are not regularly inspected. only partly formalised (no checklist
Documentation including single line detection is done by a certified
telephone in service, and/or no work order).
diagram is available near each piece contractor and formally reported.
unusual sounds, fire
of equipment. Work orders are automatically
detection, etc) and checks
generated.
for proper functionning
analyse is done.
Inspections are done from time to inspected (overheating). Every 2 or 3 plant cos phi data are compared and
There is no regular preventive time but they are not planned. major turnarounds protections are corrective actions are taken if
Condensers
inspection. Checklists and procedures are partly checked (max intensity, thermal, necessary. Every 3 years a
available. homopolar, fuses). Consumed thermographical analysis is done.
current is measured annually under Work orders are automatically
running conditions. Work orders are generated.
systematically used.
Map of the network is not updated or completely inspected (cable generated according to a defined
Map of the network is not available.
Distribution network not complete. Inspections are done connexions, cleaning of isolators, route. Thermography is done for all
There is no regular preventive
inspection from time to time but they are not checking of cable head condition) the network over a period of three
inspection.
planned. over a period of three years. All years. All cables routes have ground
inspections are scheduled and work identification markings.
orders are systematically generated.
NETWORK
Energy metering and The main substations are equiped All shops are equiped with electrical
Only incoming meters are installed. system enables load shedding in
management with electrical meters. meters which are read monthly .
case of excessive loads.
Tests are done from time to time but pressure and load levels are Work orders are automatically
Power generators There is no regular preventive
they are not planned. Checklists and recorded. All checklists and generated. If possible, borescope
(coupled to MV) inspection.
procedures are partly available. procedures are available. Every 5 to inspections are done.
7 years global maintenance is done
(wiring, yoke, etc).
Technicians
Safety procedures
or not accurate. not all formalised. electrical safety procedures are taking into account new equipment,
available and systematically applied. near misses, etc.
TY
Involved personnel (including
contractors) are well trained in safety
Only some of the electrical team are
aspects. All personnel who work in All newcomers to the electrical team
authorised/ certified; other
SAFETY
Personnel authorisation/ Technicians do not receive formal electrical areas are certified and are properly trained. Visitors entering
All
All required electrical safety All required electrical safety All safety electrical equipment is
Not all required electrical safety
equipment (PPE and tools) is equipment (PPE and tools) i+F8s regularly tested by a specialised
equipment (Personnal Protective
All
Specific safety equipment available but there is no regular stored in a dedicated place and an office. Additional equipement is
Equipment and tools) is available
inventory to check if it is in good inventory is regularly done. always availabe for contractor
within the plant.
working condition. Equipment use is controlled. personnel, etc.
M2 Managing electrical distribution 1/2
M2 Managing electrical distribution 2/2
Basic Skills Self-Assessment Grid
Check uphill & downhill There is no checking of kiln Kiln movement is checked from Kiln movement is checked on a Kiln movement is checked on a
movement movement. time to time. daily basis. daily basis and recorded.
There is no checking of teeth Job plan exists but is not used. Job plan exists and is used. Teeth Job plan exists and is used. Teeth
Check appearance of pinion &
appearance and/or nobody knows Teeth appearance is checked from appearance is checked on a appearance is checked weekly and
INSPECTION
Job plan exists but is not used. Job plan exists and are used. Roller shaft appearance is checked
Check for surface damage on There is no checking of roller
Roller shaft appearance is checked Roller shaft appearance is checked on a monthly basis and results are
roller shafts shafts. There is no job plan.
from time to time. on a monthly basis. tracked.
There are no lubrication inspection Some lubrication job plans exist but Lubrication job plans exist and are Lubrication job plans exist and are
level, pressure and
job plans and/or some checks are they are not used. Checks are done applied. Checks are done only on used. Checks are done on a daily
temperature, Check for oil or
not done. from time to time. weekdays. basis. Results are tracked.
grease leaks/spills
icians
LUBRIC
There are no lubrication inspection Some lubrication job plans exist but Lubrication job plans exist and are Lubrication job plans exist and are
Check lubrication of roller
job plans and/or some checks are are not used. Checks are done applied. Checks are done only on used. Checks are done on a daily
bearings and pinion/girth gear
not done. from time to time. weekdays. basis. Results are tracked.
Technicians
and from girth gear/pinion tank nobody knows how to take an oil time and/or sampling is not done basis and sampling operations are
monthly basis & results are tracked
for debris detection sample. There is no job plan. correctly. Job plan is not used. done properly. Job plan is used
Roller skewing rollers and/or roller technology is roller position but they are not able
know how to check kiln movement rollers, check position of rollers,
not understood/known. to skew rollers.
and induce it if needed. and check kiln movement.
Basic Skills Self-Assessment Grid
Users, like control room operators, Users, like control room operators, All users systematically receive all
receive insufficient training when receive suitable training when new necessary training when new
User training in case of
All
No training. new equipment is received or when equipment is received or when equipment is received or when
important modifications important modifications have been important modifications have been important modifications have been
carried out in the field. carried out in the field. carried out in the field.
RECEPTION
Identification of a contract The need is formally identified but it The need is formally identified and
All
The largest contracted works are All the subcontracted works are
Definition of subcontracted works is defined through a specification that systematically defined through a
Specification of the The subcontracted work is not incomplete. There is no information includes technical conditions, specification that includes technical
All
service/supply formally defined. to the subcontractor about risks deadlines, works quality, risk conditions, deadlines, works quality,
analysis and safety. analysis and contractor's obligations risk analysis and contractor's
in terms of safety. obligations in terms of safety.
1/2
Before starting the work all the
Formal communication Contractors' workers sometimes contractors' workers receive
All the contractors' workers receive
about plant characteristics Contractors' workers do not receive receive individualized individualized communication on
All
individualized communication on
and technical risks for all formal communication on safety. communication on safety and on safety and on plant in general. The
safety and on plant in general.
the contractors' workers. plant in general. worker signs an acknolweldgement
FOLLOW-UP
of this training.
2/2
Purchasing closes the requests with finished by the subcontractor and
Purchasing closes the requests
Mgrs
LUBRICATION MANAGEMENT
Operational objective: lubrication costs are less than 4% of the maintenance costs and catastrophic incidents are avoided
Work Order forms are inexistent or monitoring of levels, for oil make- possibly resulting in a new WO. All
Issuing of work orders Work Orders are sometimes used.
are not used. ups, 1st level inspections, taking of departments contribute to this
samples and oil changes. process.
Mgmt. is contracted out because no (manual mode and 1st level One spare pump is always
Mgmt. is contracted out for cost
Mgmt. of centralised lube one in the plant knows the systems, inspection) and maintained. When available. At least 2 plant persons
reasons, but no plant personnel are
system (if applicable) or no preventive maintenance work is contracted out, it is are competent in managing
qualified to monitor the work done.
procedures exist. coordinated and monitored by the centralised lubrication systems.
lube team.
(viscosity, presence of regularly, but observations are not the importance of being vigilant and
regularly. regularly. All abnormalities are
water, metals, etc. recorded. reporting all abnormalities.
recorded on the Work Order.
Safety
Safety instruction are not always
Safety instructions relating to fire Fire safety instructions are fully Persons not directly concerned with
followed. Extinguishers (indoors +
hazards are ignored. Extinguishers obeyed by all users. Extinguishers lubrication have been made aware
outdoors) work but are not
are inexistent or do not work. are inspected regularly. of safety issues.
inspected regularly.
LAB RELIABILITY
Operational objective: lab reliability index is above 75%, and lab audits do not show serious deviation from good practices
field but are not always used available in the field and are used
field. representative sampling points and
Technicians
A check standard is run by A check standard is run on a There is regular dialogue with the
operators & technicians from time regular basis, as defined in the Tech Centres and with other plants
Check standards are never run by
Run check standard to ensure to time, based on specific testing plan. Specific actions are via the Quality Network in order to
operators & technicians or/and
low testing errors and requirements by management. This taken according to well defined have good knowledge of lab
there is no knowledge about testing
repeatability activity is not really documented procedures. Testing error and testing precision and inter-analyst
errors and repeatability.
and is done only occasionally and/ acceptability ranges are well-known variability to benchmark and to
or there is no action. and followed with control charts. progress.
Technicians
Appropriate control actions (re test, Some operators & technicians are
Validate the results in acceptable Some non-compliant data have Level C + Plausibility of results is
etc.) are taken when result is out of able to analyse the results perfectly
range tolerance and manage out already been transmitted to taken into account . Trend of
specifications, as per a well defined and to estimate the influence of the
of specifications results (re-test, production without any reaction. results is followed in order to
decision tree. Production dept is process on the results. In case of
management validation, inspect, Control actions might not always be anticipate out of specifications
informed about all non-compliant deviation, a process is in place to
re-sample, etc.) taken. results.
data. identify the causes.
not clearly defined and nobody is complete. All calibration tests are
to Q2 grid) nobody is really responsible for it Best Practices are challenged.
responsible for it. done as per the calibration plan.
and/or it is not followed.
Some procedures exist for Some procedures exist for environment specification (T° /
Calibrate all equipment and take calibration of lab equipment and calibration of lab equipment and moisture). All the calibration tests Calibration methods are optimised,
appropriate action reagents, but this activity is not reagents, but they are not are done as per the procedures. Best Practices are challenged.
MANAGEMENT OF LAB EQUIPMENT & REAGENTS
Manage non-compliant No action is taken when equipment management is unsatisfactory. managed. Actions to be taken in documented and corrective /
equipment is out of calibration. There are no defined actions to be case of deviation are well defined & preventive actions are taken
taken in case of deviation. documented, and they are followed. accordingly.
specific safety equipment is (ref to risk assessment) and all. It is available at all times and time. Continuous improvement is
items
missing. accessible to all. Some equipment used by all technicians & operators. encouraged through internal &
All
is missing from time to time and/or Equipment is inspected, cleaned external inspections and audits.
it is not used by all operators. and maintained on a regular basis.
Some technicians and operators do
The laboratory is kept clean at all
not systematically clean and tidy up
times. All operators & technicians Good laboratory practices have
their equipment after use. Some
Housekeeping & proper Laboratory housekeeping is not systematically clean and tidy up been defined and could be shared
cleaning instructions exist for
organisation acceptable. their equipment after use. Cleaning with other plants (give one example
critical equipment but are not
instructions for critical equipment in "comments").
followed or no such instructions
exist and are followed.
exist.
Define the sampling plan for Sampling plan is complete and is Variographic analyses are run in
A sampling plan is available but it is
finished & intermediate product regularly reviewed taking into order to define sample frequency.
No sampling plan is defined. not complete and/or it is not
(method, location, frequency, account the representativity of Methods are reviewed and
reviewed on a regular basis.
size, responsibility and safety) samples. optimised.
QUALITY CONTROL
All
standards.
bin) is not fully available to ensure and bagging, fringe bin). Records
total compliance. of release exist & material shipped
is perfectly traceable.
formalised and there is no specific compliance. A formal system is in prevent non- conformity from
products non-conforming products.
communication with Sales & place for communication & follow- occurring.
Marketing. up with Sales & Marketing.
Manage customer complaints only a few get results and there is Rules of communication have been following investigations of customer
account at the plant level.
no systematic approach to follow- established with Sales & Marketing. complaints.
up on complaints. The complaint handling BP is
known.
Control of records is done but is not Records are traceable (original The system guarantees that all
integrated into the quality plan. The version, changes, etc.). Quality data is retained for a significant
There is no control of records.
All
Ensure integrity of data retention policy is not clearly data can be retrieved easily period (Lafarge rule = 10 years)
Integrity of data is not ensured.
defined. Uncontrolled changes according to a record retention and can be extracted without
could happen. policy. possibility of data corruption.
Basic Skills Self-Assessment Grid
Operational objective: well managed process measurements are fundamantal to optimising the reliability and efficiency of the process
Measure gas composition Plant does not perform all the gas on a regular basis. The sampling system analyse the impact of gas moisture
and measurements properly.
& gas moisture with analyses. Moisture is not is chosen according to temperature, dust and composition on pyroprocessing
Procedures are missing. The
portable gas analysers, determined on a regular basis. concentration and moisture. The line characteristics (especially the
sampling frequency is not defined
psychrometer and silica Procedures are not fully applied if appropriate method for moisture flowrate) to optimize them.
and the accuracy of measurements
gel they exist. measurements is chosen according to the Adjustements are done by following
MEASUREMENTS
is insufficient.
temperature (if T° > 150°C, the silica gel procedures.
is used, otherwise psychrometer).
greater reliability.
The plant follows a plan to track false air All the measurements data are
False air is not measured False air is tracked and repaired,
level in the preheater, raw mill, coal mill recorded and compared with other
False air measurements frequently or only in case of but with a frequency of two months
and cement mills on a regular basis, at plants results to identify points to
problem. or greater.
least monthly. be improved.
fan efficiency.
specifications are not known. have a follow up check list on
actions/checks to make in the case of
finding low efficiency.
Technicians / E
PER
Sharing of audits with other plants
An audit plan exists concerning all the
and Technical Centre. Specific
Audits are mainly done internally, audits. Assistance of TC's is not required,
Audits (Mini and full mill audits / measurements are defined
occasionally with the assistance of but sometimes discussed with TC for
audits, Mini kiln audits, Audits are not done by the plant. to investigate opportunities to
TC's. There is no formalized audit second opinion. All audits have brief
combustion audits) optimise the process not covered in
plan and/or no written reports. written report with conclusions and
standard audits. For example -
practical actions to improve the process.
precalciner temperature profile.
Basic Skills Self-Assessment Grid
Sampling point location Partial study, not sufficient to Formal study considering
Distance between sampling point
(for analyser probes: No formal technical study on ensure best location is chosen (e.g. accessibility, representivity of
and analyzer is minimized
place, direction, angle and sampling point location. no comparison of alternative measurements and manufacturer
(response time < 30 seconds).
cooling) locations). recommendations.
Choice of sensor device consideration of criteria given in B Study of sensors already installed
when choosing, and/or choice not reliability, precision of
(cf. table below) and/or without collaboration of helps optimize future choices.
made in a formal manner. measurements and supplier
process dept.
recommendations.
Partly formalized tech. study does Specs are formalized and include Comparative study of sensor
Tech. Study preparation
No formal tech. study prior to work. not address all issues related to plant specificities and supplier quality (reliability, response time,
INSTALL
for installation
sensor installation. recommendations. etc.)
Technicians
1/2
Analyzer environment is temp.
Supplier recommendations for There is a system for eliminating
No study is done of analyzer controlled and equipped w/
Gas Analyzers: Ensure installation are followed, but build ups (if study indicates need)
environment; no actions are taken dry/clean compressed air blowback
stable environment and cleaning of probe an other actions and temp. monitoring to ensure
to ensure stable measurement system (if study indicates need).
measurement conditions to ensure stable conditions are stability of measurement
conditions. Probe condition is regularly
done only occasionally. conditions.
checked.
All
Some critical sensors are regularly Regular visual checks of all critical
They are not regularly inspected Job plan is optimized according to
Maintenance of other checked, but no details study has sensors (identified by study), with
and action is taken only in case of maintenance experience with each
sensor types been done to determine criticality an updated record sheet for each
problem/incident. type of sensor.
levels. one.
analyzer calibrated, but there are procedure. Preventive replacement Job plan is optimized and
Maintenance of gas Cabinet is inspected only form time
no written procedures. Preventive of filters, pump valves, humidity measurement chain (probe to
2/2
Collaboration with observed irregularities but are not unavailability due to minor incidents
collaboration with operations and are used (incident simulation,
operations personnel able to take appropriate action. is analyzed. Preventive measures
personnel. checklists, coherence between
Observations are followed up on. are taken.
diagnosis and prescribed actions,
etc.)
HISTORIZATION
done but not planned around plant the plant and equipment supplier where all spare parts are
stoppages. inspections are planned during the registered.
plant shutdown.
All
Disk backup are systematically All backups are done and easily
Software agent have been installed
Disk backups are not done done but their follow-up is not retrievable.Bachups are stored in a
Data backup management to verify that backups have been
systematically. planned or the scheduling is not fireproof cabinet located in a room
done.
always respected. other than the PC room.
Technicians
Software
Equipment is monitored with the Historic data are used to follow all Automation team is able to create
Technicians
computer products. Anticipation and are based on failure rate watch. Precise studies are done to
changes not anticipated. not based on failure rate analysis.
UPGRADE
tranmission of data to other in the plant. and/or solved internally. detecting problems.
and problem solving.
systems
Inter-application architecture only connect a part of systems PCS team is sufficient to manage a
application has been developed. access to plant databases are well
within the plant. contractor for developing inter-
managed.
application architecture.
Technician
Most plant problems are solved All hot line calls are logged for
There is no hot line or support Support exists but only small
Internal support (hotline) internally, only the most analysis (statistics, weakness, etc)
s
when the IT system is modified. diagnostics/interventions ( e.g.: there is specific training for
system is implemented.
restart the server) newcomers.
Two levels of responsibility are mainly The column «comments» should be used in
identified: Technicians (operators, particular:
supervisors, etc.) & Managers. Each level includes the level below - each time you hesitate between two levels
(i.e. you are at level A only if you do what is - each time you choose level A
described at level B & A, etc.)
- each time the task does not concern your plant