F1501-FRHO-F2-006

Vital checkpoint Data Agreement (VDA)


Part Name STAND COMP,MAIN Serial No QCHO16120293
Part No 50500KZK D001 Revision No 0
Dcn No M-16-F-0727 Part Importnce HA Revision Date --
Rev
S.No No Criticality Parameter Inspection Method Specification Frequency
1 0 SURFACE TREATMENT LAB REPORT HESD2016CLASS-1,GRADE-2 (BLACK) ONCE/ MONTH
2 0 WELD BEAD DIMENSION VISUAL SHOULD BE AS PER DWG. 100%
3 0 WELDING LENGTH DVC AS PER DRAWING 5 PCS /LOT
4
5
0
0
APPROVED
WELD PENETRATION
MATERIAL (ALL CHILD PARTS)
LAB REPORT
MTC
MIN20%OFTHK
AS PER DRAWING
ONCE/ MONTH
ONCE/ 6 MONTHS
6 0 WELD BEAD DIMENSION VISUAL SHOULD NOT PROTUDE IN DRAIN HOLE 100%
7 0 APPEARANCE VISUAL NO BURRS ALLOWED 100%
8 0 APPEARANCE VISUAL NO CRACKS ALLOWED 100%
9 0 APPEARANCE VISUAL NO SHARP EDGES ALLOWED AT THE CORNERS 100%
10 0 APPEARANCE VISUAL NO BLOW HOLES ALLOWED 100%
11 0 APPEARANCE VISUAL NO PIN HOLES ALLOWED 100%
12 0 APPEARANCE VISUAL NO POROSITY ALLOWED 100%
13 0 APPEARANCE VISUAL WELDING BEAD SHOULD BE PROPER 100%
14 0 APPEARANCE VISUAL NO WELDING SHOULD BE MISSED 100%
15 0 APPEARANCE VISUAL NO WELDING SHOULD BE MISSED 100%
16 0 APPEARANCE VISUAL NO WELD SPATTERS ALLOWED 100%
17 0 APPEARANCE VISUAL NO UNDER CUT ALLOWED 100%
18 0 APPEARANCE VISUAL UNEVEN COLOR NOT ALLOWED 100%
19 0 APPEARANCE VISUAL NO PAINT CHIPS ALLOWED 100%
20 0 APPEARANCE VISUAL NO RUST ALLOWED 100%

Note:-In specification column,spec range(min,max) is mentioned due to SAP sync.For new VDA specification will be same as mentioned in drawing.
Jeevan Nandkumar
Supplier Name All Concern Suppliers Auto Approved Rakibe
RECEIVED BY ISSUED BY PREPARED BY CHECKED BY APPROVED BY
Issue Date/Time 1/9/2017 2:20:09 PM PURCHASE SQA
Supplier HMSI MANESAR HMSI

Disclaimer:-Authorize use of this document is limited to the concern supplier of HMSI


1/2
F1501-FRHO-F2-006

Vital checkpoint Data Agreement (VDA)


Part Name STAND COMP,MAIN Serial No QCHO16120293
Part No 50500KZK D001 Revision No 0
Dcn No M-16-F-0727 Part Importnce HA Revision Date --
Rev
S.No No Criticality Parameter Inspection Method Specification Frequency
21 0 APPEARANCE VISUAL NO SCRATCHES ALLOWED 100%
22 0 APPEARANCE VISUAL NO PAINT PEEL OFF ALLOWED 100%
23 0 APPEARANCE VISUAL PART SHOULD BE FREE FROM DENTS 100%
24
25
0
0
APPROVED
APPEARANCE
PRESS DROOP SIDE
VISUAL
VISUAL
NO FILLING MARKS ALLOWED
AS PER DRAWING
100%
100%
26 0 GAUGE FITMENT RECEIVING GAUGE PART SHOULD QUALIFY IN RECEIVING GAUGE 100%
27 0 DIMENSION VC 189 +1 5 PCS /LOT
28 0 DIMENSION VC 30-0.5 5 PCS /LOT
29 0 DIAMETER VC 12.10 +0.1 5 PCS /LOT
30 0 CONCENTRICITY HEIGHT GAUGE Ø0.1 WRT A 5 PCS /LOT
31 0 DIMENSION HEIGHT GAUGE 223 ±1 5 PCS /LOT
32 0 DIMENSION HEIGHT GAUGE 14.5 +0.5 5 PCS /LOT
33 0 ANGLE BEVEL PROTRACTOR 25° ± 3° 5 PCS /LOT
34 0 DIMENSION HEIGHT GAUGE 94.5±0.5 5 PCS /LOT
35 0 OPERATING CHARACTERISTICS VISUAL DIM *249 SHOULD BE SMOOTHLY TURNABLE 100%
36 0 COATING SPECIFICATION VISUAL PRVENT COATING AT MARKED AREA IN DWG 100%

HMSI MANESAR
Disclaimer:-Authorize use of this document is limited to the concern supplier of HMSI
2/2