Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

#205 li·t•

Means Success In Electronic Servicing


tech •.
..1ps
Troubleshooting SMPS Problems (PWM Type)

Switch Mode Power Supplies (often called current conditions by shutting do wn. MIC #1 - Unregulated B+ - This circuit
"choppers'', switchers" or simply Most SMPS component failures or load includes the linear power supply, standby
"SMPS ") are used extensively in many changes cause the SMPS to completely supply, primary of the switching
AC-powered devices, such as computers , shut down and produce a "dead chassis" transformer, and the switching transistor.
monitors, television receivers, and VCRs. symptom. This can make troubleshooting
This Tech Tip provides a 6-step procedure difficult and confusing. Is the shutdown MIC #2 - Startup & Drive - This section
to use for isolating problems in the PWM caused by too much high voltage?; the B+ provides the control signal for the
type of SMPS that are typically used in being pulled down? ; too much load switching transistor. The heart of MIC #2
consumer electronic equipment. Tech Tip current?; a supply component failure? ; or is the driver circuit. It can be a single
#203 explains how SMPS operate.Tech a defective safety circuit? stage transistor or a current mode
Tip #204 provides information on how to controller IC.
determine whether the SMPS is the cause Without a logical procedure , SMPS
of an inoperative chassis. troublesh ooting can be frustrating . But MIC #3 - Secondary Circuits - The
you can break the SMPS shutdown loop secondary circuits include the secondary
Why SMPS Troubleshooting Is and quickly isolate the defective area in 6 winding of the switching transformer and
Different Than Linear Supplies easy steps. the components (diodes capacitors, etc.)
that provide power to the loads. Most
Conventional linear power supplies The Four Key Circuits SMPS have 2 to 5 loads.
usually continue to supply an output, even
if a load shorts, a filter capacitor opens, or Before we look at these six steps , let's MIC #4 - Feedback & Control - Most
half of the bridge quits. Isolating the briefly review the four general sections PWM SMPS feedback loops provide four
defective component in a linear supply (most important circuits or MIGS) that functions:
usually consists of tracking too low, too make up a SMPS, as shown in Figure 1. •Output voltage sampling for regulation
high or lost DC voltages. The SMPS, on (Refer to Tech Tip #203 for a complete • High voltage monitoring
the other hand, requires a different explanation of each MIC). •System control micro for power ON/OFF
•Ground isolation through opto-isolators
troubleshooting process. Here's why:
Linear Power
Supply
First, replacing a burnt resistor, shorted Switch
diode or bad transistor in a SMPS does
not guarantee a fix as with the linear
supply. Simply fixing the SMPS supply by
replacing a burned part often causes the Load

same components to burn up again.

Secondly, when troubleshooting a linear LV DC

supply, a variac is used to slowly bring up


the AC line voltage while you monitor the
current draw. Not so with most SMPS. Load
You have virtually no chance to back off
the AC power once the SMPS kicks in. It
either puts out no current or full current.
Opto
MIC4
Isolator
Perhaps the biggest difficulty with
troubleshooting a SMPS is a direct result Hot Cold ON/OFF from
from system HV shutdown
of one of the SMPS benefits - it's ability to Ground Ground
micro
protect itself from over-voltage or over- Fig. 1: A SMPS contains four key circuits.

#
205
!i·tii
6-Step Troubleshooting Procedure
Step #1
The following six steps are proven to be a Check Standby
safe , effective method of isolating the Supply
problem to a specific MIC. Combining
these steps with dynamic component
Normal I Missing

analyzing will get even the toughest SMPS • Repair Sta ndby Supply
up and running.
Step #2
WARNING:
Substitute for
Always use an Isolation Transformer. Main Load
All SMPS contain both hot and
- Outputtoo
high / low
I SMPS IOutput
dead normal - SMPS is good
chassis (floating) grounds. You will • check external safety
cause damage to the SMPS and/or shutdown circuits
your test equipment if you connect • check loads
test equipment to a hot ground, or Step #3
attempt to tie the hot and cold Remove Drive
grounds together. to Switching
Transistor

Keep the following things in mind when


performing the SMPS troubleshooting
procedure: Step #4
Check MIC1
• Always use the correct ground reference (B+ path)
when making a measurement. Using the Normal I Missing
wrong ground reference will result in an
incorrect reading. • Repair Li near Supply

•Hot grounds ~are usually found on the Step #5


primary side of the switching transformer. Check Driver Ckt.
Use this ground for all MIC 1
measurements. Normal I Missing
• Start-up circuit
• Driver o scillator
•Chassis mgrounds are found on the 1 Ir

secondary side of the switching Step #6


transformer. Use this ground for MIC 2, 3 Dynamic Check of
& 4 measurements. Feedback & Control Ckt.
Normal Missing
•The opto isolator input (from the control
I
circuits) is measured with respect to
chassis ground .
• "Power On" from Syscon uP • Repair Feedback Ckt. I
• Over-voltage Shutdown
• Over-current Shutdown
•The opto isolator output (to primary side
driver or controller stage) is measured Fig. 2: Follow these steps to quickly and safely isolate SMPS problems
with respect to hot ground.
The flow chart in Figure 2 outlines the six the SMPS can operate. (Not all SMPS
troubleshooting steps. Perform the steps have standby supplies) . Check for standby
• Be Prepared to Make All Parameter
in order. Each step funnels the problem to voltage with the chassis plugged into an
Measurements. Efficient troubleshooting
a specific MIC and suspect components. isolation transformer set for an output of
depends on your ability to quickly
Any one of the troubleshooting steps may 11 ?VAC , (such as the PR57 POWERIT~)
measure different signals and voltages:
isolate the SMPS problem. Often , you may but with the chassis power (chassis
DC from tenths of a volt to 160V; signal
not need to do all 6 steps because the ON/OFF switch) turned off.
voltages from 2 VPP to >400 VPP; and
problem is found in one of the first steps.
frequencies from 40 kHz to 150 kHz.
Following is an explanation of each step . Some chassis use a second, smaller
SMPS as the standby supply. The fact that
We recommend using the SC61 , SC3080
#1 - Check The Standby Supply the standby supply is working eliminates
or SC3100 Waveform Analyzer, since they
many suspect components. The IC Driver
allow you to make all measurements with
The standby voltages to the driver and in MIC #2 is always a suspect in a shut-
just one probe connection .
microprocessor must be correct before down condition, and is often needlessly
replaced. The standb y switcher is monitor this is the output that powers the Disconnecting the input signal to the main
physically smaller, and has lower power collector of the horizontal output switching transistor allows you to safely
handling capabilities than the main transistor. By substituting for this load troubleshooting the SMPS circuits, wh ile
switcher, but it is driven by the same you effectively disable the safety the chassis is turned on , without
Driver IC as the main switcher. Therefore, shutdo wn controls that come from the accidentally producing an output from the
if the standby switcher is running the external circuits. SMPS.
Driver IC is likely OK . The shutdo wn
condition is caused by something else The size of bulb you use depends on the #4 - Check MIC 1 Circuits
that preventing the Driver IC from load you are substituting . For example , if MIC #1 includes all the B+ path from the
supplying a control signal to the main you are substituting for the load on the output of the linear supply to the ground
switching transistor. 130 VDC B+ supply in a television rece iver point of the emitter or source of the
or monitor, use a standard 60 watt, 120 swi tch ing transistor. Begin by checking
If the standby supply voltage is correct, VAC light bulb. If you are substituting for for B+ voltage at the switching transistor:
but the main SMPS is still not operating , the 15 volt B+ output in a VCR supply, use
move on to step #2. a 12or18 volt bulb . 1. Connect the Waveform Analyzer to the
switching transistor's drain or collector.
#2 - Substitute For The Main Load You wi ll need to open the circuit path to Set it to measure DC voltage.
remove the normal load. Make sure to
An important step in troubleshoot ing break the circuit after the feedback take 2. Set the PR57 to zero volts AC output.
SMPS problems is to separate the SMPS off point. Removing the horizontal output Press the "0-1 .5A/175W" output current
output from the rest of the chassis. This transistor in a television or monitor will monitor button.
helps you determine if the shut down break the circuit, but do not connect the
supply symptom is due to the SMPS bulb in place of the horizontal output 3. Gradually increase the PR57's AC
supply itself, or if the symptom is due to transistor. The primary of the flyback is output while monitoring the output
an outboard circuit or load. (A similar not designed to handle a continuous current.
procedure is given in Tech Tip #204 for current. Connect the light ahead of the
isolating problems to the SMPS or primary, as shown in Figure 3. You will observe one of the follo wi ng
external circuitry). conditions :
After you substitute for the load, you will
Most PWM SMPS will not operate without see one of four conditions when you turn • Low current, normal B+ (approximately
an adequate load current. Therefore you on the SMPS: 160 VDC) with PR57 output at 117 VAC.
can not simply disconnect the loads . This means that the B+ supply is good .
Instead, most manufacturers recommend • Bulb lights and measured voltage is But there still might be a problem in the
replacing the main load with a light bulb normal MIC 1 circuity:
that has approximately the same wattage This means that the SMPS is working
rating. The light bulb provides current properly. Something external to the SMPS Check the switching transistor to make
limiting and provides a suitable, constant is causing the shutdown . Possibilities sure it is not open . Use a dynamic
load for the SMPS. include excessive HV, excessive current transistor , such as the TF46 "Super
draw by one of the loads, or a defective Cricket.check
The main B+ load is the output of the safety circuit.
SMPS that contains the feedback divider Also check the resistor(s) in the emitter or
network. In a television receiver or • Light bulb doesn't light (SMPS doesn't source lead of the switching transistor. If
start) you suspect they may have changed in
Connect bulb after Open B+ Load
• Light comes on but goes out (SMPS value , replace them with the
starts but goes into shutdown) manufacturer's exact replacement. These
• Light is very bright (indicates possible resistors are precise tolerance , and are
regulation problems) critical to safe operation of the SMPS.
These last three conditions indicate that
something is wrong with the SMPS . If the transistor and resistors are good ,
Continue with the remaining steps until proceed to Step #5.
you locate the problem.
• No DC and no AC current draw
#3 - Remove the Drive Signal from the There is an open in the B+ supply. Check
Main Switching Transistor the fuses , safety resistors, diodes, and
Switch Mode Supply Horizon tal Output Ckts.
switching transformer primary.
Open the signal path between the Drive
Fig. 3: Use a light bulb as a substitute load and the gate or base of the switching •No (or low) DC & increasing AC current
for the 8+ output of the SMPS. Disconnect the transistor. You can easily do this by Lo w or missing DC voltage along with
normal 8+ load, then connect the bulb after unsoldering and lifting any one of the increasing AC current is caused by a
the feedback takeoff point. components in the signal path. short in the B+ supply itself, or some-
li·tl' #
205
J
where within MIC #1. Check the switching Linear
transistor, bridge, and filter capacitor. Supply

Also check the primary winding of the


switching transformer for a DC short to substitute load
the core or to another winding .
Flyback

#5 - Check Driver Circuit

First, confirm that the Driver IC has start- Vary the applied
up voltage. In most switch mode power voltage around the
normal B+ value
suppl ies the start-up voltage is obtained
using the LC102
from a resistor divider network off the Leakage supply
linear unregulated B+ supply . Always
check for start-up voltage before checking
Power ON From HV
if the oscillator is running. Connecting a from safety
probe to the oscillator test point can SYSCOM uP shutdown

"kick-start" the oscillator. Ground

Secondly, check all of the oscillator test


Fig. 4: Apply an external DC voltage to the feedback circuit to confirm the operation of MIC 4.
point waveform para meters : DC , PPV ,
and frequency . The oscillator frequency 2. Connect the LC102 power supply to the SMPS Component Analyzing Tips
must run at the switch mode suppl y B+ point , after the feedback divider
frequency. If the frequency reads high network. (The same point where the light Don't use general replacement parts.
(the oscillator waveform may be noisy and bulb was connected). The switching transistors and diodes used
contain with glitches) confirm the in SMPS must operate effectively at high
f requenc y using the Delta Frequenc y 3. Connect the Waveform Analyzer to the currents and high frequencies . The most
function on the waveform analyzer. If the control input of the Driver. (Output of the reliable results are achieved using the
frequency is more than 10% too high, the Opto Isolator) Press the "DCV" function . manufacturers' original parts.
controller IC is defective.
4. Set the PR57 to 117 VAC output and ESR is a critical capacitor parameter.
NOTE: Usually a current mode controller turn the chassis on. Due to the high operating frequency of
will not output a drive signal to the SMPS , ESR (equivalent series resistance)
switcher with the SMPS disabled. Make 5. Vary the LC102 supply voltage from is a common failure mode of electrolytic
your measurements at the oscillator test five volts below the normal B+ voltage to capacitors used in SMPS . High ESR
point on the controller IC) five volts above the normal B+ voltage , causes an array of symptoms , from
while monitoring the DC reading on the shutdown to wrong regulation . Replacing
#6 - Perform a Dynamic Check of The Waveform Analyzer. a suspect cap with an off-the-shelf part
Feedback &Control Circuit may onl y make matters worse .Test an y
If the feedback circuitry is working , you suspect capacitors with an ESR tester,
This final troubleshooting step confirms will see an increase in the DC voltage at such as the Sencore LC102 .
proper operation of the Feedback and the Driver input as you increase the
Control circuits , MIC 4. Often failures in applied voltage above the normal B+ level. Test the Switching Transformer
MIC #4 are caused by a defective A 1 VDC change in the applied voltage SMPS switching transformers , like flyback
transistor which shuts down the entire typically may only show a .1 voe change transformers , are high Q transformers .
feedback loop. This dynamic feedback at the Driver. They are responsible for transferring a
circuit check will quickly isolate any large amount of energy in a short period
problem in MIC 4. If there is no change at the Driver input, of time. A single turn short will shut down
check the opto isolator. (Remember to the SMPS. Be sure to use the patented
To check these circuits you will need to reference the correct ground.) With a Sencore ringing test to test any suspect
apply an external vol tage (equal to the changing DC into the opto isolator there switching transformer.
normal, main B+ output of the SMPS) and should be corresponding change in the
confirm that the circuits respond properly output DC voltage. Continue checking the
to it. Use a variable, current limited DC MIC #4 feedback loop unti l the defect is For More Information,
power supply, such as the leakage power located . This includes the "Po wer On " Call Toll Free 1 -800-SENCORE
supply in the Sen core LC102 "AUTO Z". command from the system control (1-800-736-2673}
microprocessor, and the output from the
1. Disconnect the substitute light bulb safety circuits, such as over-voltage and
load from main B+ output of the SMPS. over-current shutdown. Be sure to check SEl'JCORE
the electrolytic capacitors for ESR. 3200 Sencore Drive, Sioux Falls, SD 57107

11'1¥1 #205 Form 4926


P rin tarl In 11 C::: t;.

You might also like