1. PURPOSE
The purpose of this standard is to provide guidelines for testing the emissions of Light Vehicles
and Mobile Equipment being operated in underground mines to ensure safe air borne levels of
NOx (oxides of nitrogen) and CO (carbon monoxide) gases.
2. SCOPE
2.1. This standard addresses the minimum requirements of emission tests for Light Vehicles
and Mobile Equipment that operate in the DPMUnderground Mine Areas.
2.2. This standard applies to:
a. DPMBusiness Units, Partnership and Contractor Companies who work at DPM
Contract of Work (COW) area.
4.3. The Underground Mine Maintenance Department using a DRAEGER MSI-150E, or other
MSHA approved emissions analyzer, shall conduct the emission tests. Testing shall be
done in conformance with manufacturer’s instructions.
4.4. Light Vehicle Emission Limits for undiluted gases at the tail pipe shall be established as
follows for both idle and high RPM.
NOx – 400 PPM
CO – 400 PPM
4.5. Mobile Equipment Emission Limits for undiluted gases at the tail pipe shall be established
as follows for both idle and high RPM
NOx – 1000 PPM
CO – 2000 PPM
4.6. The applicable emission limits for undiluted gases shall be those above or those specific by
the engine manufacturer, whichever is lower.
5. STANDARDS OF ACCOUNTABILITY
5.1. DPMTechnical Mine Manager
a. Ensure DPMhas its own FRESH Standard to address the requirements for emission
test for light vehicle and mobile equipment operated at underground mine area and
review the standard at minimum every three (3) years.
b. Provide resources for the effective implementation of this standard.