Hybrid solar inverter REVO II and REVO E function , display difference

Model
Describtion Function
REVO II REVO E

Apperance N/M

Utility will first power the load . The solar charges the battery. When
the solar is insufficient, the utility and the solar will charge the battery
together. When there is not utility, the solar or the battery charge AC priority(default)
load.

Solar energy provides power to the loads as the first priority. When
the solar energy is sufficient, the extra energy will charges the battery.
When solar energy is insufficient for load, batteries and solar will
supply power at the same time. When solar energy and batteries are PV priority
insufficient or solar energy is unavailable, utility supply power to the
load.

The solar charge the laods priority. When the solar energy is Working modes YES YES
sufficient, the extra energy will charges the battery. When solar energy
is insufficient for load, batteries and solar will supply power at the Battery priority
same time. Utility provides power to the loads when battery voltage
drop to low-level warning voltage or setting point, and the utility
power will charge the battery.

Solar energy charges the load as the first priority.The more solar
energy shall charge the battery. When solar is insufficient, the solar
and utiltiy shall charge the laods and battery together. When there is AC+PV
not solar, the utility shall charge the loads and battery at the same
time. When there is not solar and utility, the battery shall charge the
loads.

220Vac/
Output voltage
230Vac(default)/240Vac
output YES YES
50hz or 60hz is availiable 50Hz(default)/60Hz
Lead acid battery YES
REVO-II & REVO-E support all types batteryies. REVO-E has not the
Battery type lithium-iron battery YES YES
lithium battery communication.
User defined (can set floating
YES
charge/ absorbtion charge)

For REVO-II & REVO -E low voltage alarm is optional 18.0-23.0vdc (24V
device) 36.0-46.0vdc(48v device) Battery low voltage alarm and cut-off voltage
For REVO-II & REVO -E cut-off voltage is optional 18.0-23.0vdc(24V (adjustable) YES YES
device) 36.0-46.0vdc(48V device)

Input current AC charge(10-60A)default 30A YES YES

Input current PV input charge current(1-20A)default 15A YES YES

9pcs in parallel max parallel Single phase parallel /three YES YES
phase parallel

Solar energy feed into the utility Grid-tied YES YES

remote monitor WIFI function YES YES

The PV energy power can be set to ZERO. Then it can account the PV PV energy generated reset YES YES
energy data again.

All of these 2 devices have fault , alarm and warning mute choice Mute choice YES YES

The other language can be setted into REVO-II, if the language English(default)
descibtion can be offered by customers. language Chinese , English English
Chinese
Dispaly Displsy Screen Tounch Screen LCD Screen

90-280VAC Wide range(default)


input YES Only with wide range
170-280VAC Narrow range

The data and time can be set for REVO-II only. Date and time setting(year/month/day/minutes) YES NO

The energy output of the system is controllable .Charging when the


electricity price is low.discharge when the electricity price is high . Peak vally charge YES NO
Realizing peak cutting and valley filling.

REVO-II has restore factory defaults function Other setting(Restore factory defaults) YES NO
REVO-II records the day /month /year and total PV energy. PV energy generated (year、month, day、and Only real - time power and
REVO-E just shows the real-time & total PV energy YES total generation power
total statistic)
REVO-II has day /month /years power generation record & event
records. History information YES NO

this function is for some country which government not support on


grid policy . For example, If there are 2 different groups of load, one
group is the Light load, the other is heavy loads, in this condition,
these two loads power can more than inverter power, because light
CT function YES NO
loads connect at the output side of the inverter , the heavy load
connect at the input of AC side , if there is still excess solar power after
the needs of two loads, the CT will prevent the excess PV energy feed
into the utility.

Display compare

date、version、type、operation mode(AC or Only version number of the


REVO-II shows working modes. REVO-E shows working modes code. YES program
inverter mode)

The input voltage & frequency can be displayed in these 2 models. AC input(voltage / frequency) YES YES

The output voltage & frequency can be displayed in these 2 models. output(voltage / frequency) YES YES

All of these 2 types displays PV energy. PV(voltage / current) YES YES

All of these 2 types displays the loads capacity. load( load KW / percentage) YES YES

REVO-II has restore factory defaults function Other setting(Restore factory defaults) YES NO

REVO-II records the day /month /year and total PV energy. PV energy generated (year、month, day、and Only real - time power and
YES
REVO-E just shows the real-time & total PV energy total statistic) total generation power

date、version、type、operation mode(AC or Only version number of the


REVO-II shows working modes. REVO-E shows working modes code. YES
inverter mode) program

REVO-II displys battery voltage and current. REVO-E just displays


battery voltage. Battery (voltage / current) YES No current

REVO-II will display the fault. REVO-E just display the fault code. alarm/fault(code / information) YES Only code