Safety Controller
Safety FA solution
Global Player
GLOBAL IMPACT OF
MITSUBISHI ELECTRIC
Through Mitsubishi Electric’s vision, “Changes for the Better“ are possible for a brighter future.
2
Maximizing productivity and reducing total cost while
adding value across the manufacturing enterprise
e-F@ctory is the Mitsubishi Electric solution for adding value across the manufacturing enterprise by enhancing productivity,
and reducing the maintenance and operations costs together with seamless information flow throughout the plant. e-F@ctory
uses a combination of factory automation and IT technologies in combination with various best-in-class partner products
through its alliance program, offering solutions to reduce total cost while improving operations, production yield, and efficient
management of the supply chain.
since2003
Programmable
Shop floor Sensor Drive Mechatronics Energy-saving
Controller
INDEX
Safety standards················································ 6 Safety programmable controller Safety drive products······································ 38
Lineup································································· 9 MELSEC-QS Series········································· 22 Support····························································· 40
MELSEC iQ-R Series Safety controller Product list······················································· 44
iQ Platform-compatible PAC···························12 MELSEC-WS Series········································ 30
3
A wide range of safety
to large-scale system
Ensuring next level of safety between the operator and
machine
Based on a principle of separating machines from operators, safety protection measures were implemented on the basis of
risk assessment and safety control such as implementation of an emergency stop. The advancement of technology realizes
operations such as slowing down the operation speed when an operator approaches a machine and continuous operation
without stopping when an operator is away from a machine. The concept of safety has shifted to a level where operators and
machines can work in collaboration ensuring increased safety. Mitsubishi Electric offers a total safety solution which realizes
“collaboration” of operators and machines with a large variety of products.
4
products for small-scale
MELSEC-QS Series
MELSEC-WS Series
All Series comply with EN ISO 13849-1 Category 4/PL e and IEC 61508
SIL 3 safety standards
5
International safety standards
International standards for machinery safety are hierarchically classified into the following types:
••Type A standards (basic safety standards): ISO 12100
••Type B standards (group safety standards): ISO 13849-1, IEC 61508, etc.
••Type C standards: Individual product standards
Identification of use
and foreseeable misuse
NO
Was tolerable risk attained?
YES
End
6
EN ISO 13849-1 Safety categories
"Safety categories" are indicators used to determine specific safety measures based on risk assessment results.
Risk analysis Severity of injury Rarely, for • Shall meet the requirements of Category B. • Although the loss of the safety
Possibility of avoidance
brief period • Shall observe safety principles. function can be detected by checking,
2 • Shall check the safety function at appropriate the safety function is lost between
Unavoidable intervals. checks.
Serious Frequency/duration • Shall meet the requirements of Category B. • The safety function is not lost by a
injury of exposure to risk • Shall observe safety principles. single fault.
Avoidable • Design requirements: A single fault shall not • Some but not all faults can be
3 lead to the loss of the safety function. detected. Accumulation of
• Detect as many single faults as possible. undetected faults may lead to the
Frequently, for Possibility of avoidance loss of the safety function.
E.g.) Risk evaluation for press long period
machine's drive area: • Shall meet the requirements of Category B. • The safety function is always in effect
1) Severity of injury: Serious Unavoidable • Shall observe safety principles. whenever a fault occurs.
2) Duration of exposure to risk: Frequently or for long period • Design requirements: Detect a single fault at • Faults will be detected in time to
3) Possibility of avoidance: Unavoidable 4 or before executing safety function. prevent the loss of the safety
In cases where this is not possible, function.
➝
PLr L
P1 S F P
F1 a
P2 Severity of injury Frequency or duration Possibility of avoiding
S1 of exposure to risk or deterring risk
P1 b
F2
S1 F1 P1
P2
1
P1 c Rarely to low frequency Possible under
Minor injury
F1 or for a brief period certain conditions
P2
S2 d S2 F2 P2
P1
F2 Frequently to
P2 continuously or for a
e Serious injury Almost impossible
H long period
7
Advantages of installing safety programmable controller or
safety controller
■■Complies with international safety standards
The MELSEC safety programmable controller and safety controller are international safety standard certified controllers for
safety control. Compliance with international safety standards assures safety operation of electronic devices and programmable
controllers, realizing safety applications easily.
■■Safety control execution
When connected with safety devices such as an emergency stop switch or light curtain, the safety programmable controller
executes safety control by turning safety output off to stop power to a source of potential hazard, such as a robot. Safety control
program enables emergency stop operation safely and flexibly.
■■Equipped with fault monitoring function and self-diagnosis function fulfilling safety standard requirements
By periodically executing fault monitoring and self-diagnosis, power is safely shut off in the event of failure in the safety
programmable controller or safety controller.
Before
An operator loading materials can be caught Dangerous when loading materials without Starting a machine when an operator is
between a robot area and a fence. noticing the production line in operation. within the safety fence can be dangerous.
After
The production line cannot start while an The production line is safely stopped by By detecting laser scanner signals, startup
operator is within the area as detected by the detecting light curtain signals when an is interlocked when an operator enters
safety mat. operator enters the exclusion zone. an exclusion zone, even if the operator is
obscured from view.
8
Total safety solution lineup
Mitsubishi Electric provides a total safety solution by incorporating safety devices complying with international safety standards.
9
Selection points
Select the safety control devices most suitable for your system configuration from the lineup.
YES NO
YES NO
••Integrated generic and safety control ••Safety control of medium to large- ••Safety control of small to medium-
of medium to large-scale systems scale systems scale systems
••Servos, inverters, and robots can be ••Ladder programs and safety function ••Supported Flexi Line/Flexi Link for
controlled through their connectivity blocks enable flexible programming safety communications between
with the MELSEC iQ-R Series via safety controllers
CC-Link IE Field Network ••Setup and logic creation are
••Programming and maintenance possible using the Setting and
using GX Works3 Monitoring Tool
10
MELSEC SELECTION GUIDE
Select the products most suitable for your system.
Series
Safety CPU
Number of safety CPU models 4 1 3
Integrated generic and safety control ●*1 - -
Ladder diagram (LD) ● ● -
Structured text (ST) ●*2 - -
Function block diagram (FBD) ●*2 - ●
80K/160K/320K/1200K
Program capacity (step) 14K 255 (Function Blocks)
(40K for safety programs*3)
Integrated safety and non-safety communication
CC-Link IE Field Network ● ●*4 -
Safety communication
CC-Link Safety - ●*5 -
Flexi Line/Link - - ●*6
Non-safety communication
Ethernet ● ● ●
CC-Link ● ● ●
CC-Link IE Control Network ● ● -
MELSECNET/H - ● -
Safety I/O module
Max. number of connectable safety remote I/Os per master
120 42 -
station
QS0J65BTB2-12DT: 16 WS0-XTIO: 8
No. of input points (single wiring) (point) NZ2GFSS2-32D: 32
QS0J65BTS2-8D: 16 WS0-XTDI: 8
QS0J65BTB2-12DT: 4*7
No. of output points (single wiring) (point) NZ2EXSS2-8TE: 8 WS0-XTIO: 4
QS0J65BTS2-4T: 4*7
Engineering software
Integrated programming of generic and safety control ● - -
Programming development environment GX Works3 GX Developer Setting and Monitoring Tool*8
Standards
EN ISO 13849‐1 Category 4/PL e Category 4/PL e Category 4/PL e
IEC 61508 SIL 3 SIL 3 SIL 3
KOSHA S-Mark - ● ●
*1. A power supply module, base unit, and network module can be shared with the CPU for generic control.
*2. Only for executing generic control programs.
*3. Up to 40K steps of program capacity of general program can be used for safety program.
*4. Safety communication is enabled only between the MELSEC-QS Series CPUs.
*5. Safety communication is enabled only between the MELSEC-QS Series CPUs and Safety remote I/Os.
*6. Safety communication network which connects between the MELSEC-WS Series CPUs with dedicated cables.
*7. When source and sink type are selected
*8. For details on how to obtain the Setting and Monitoring Tool, please contact your local Mitsubishi Electric sales office or representative.
11
MELSEC iQ-R Series
iQ Platform-compatible PAC
USB
12
Integrated generic and safety control
The safety CPU can be installed directly on the MELSEC iQ-R Series base rack and can execute both safety and generic
programs, enabling easy integration into existing or new control systems. The MELSEC iQ-R Series power supply module, base
unit, and network module can be used with safety and generic control modules, reducing costs and saving space.
Before
Generic program (non-safety) Safety program
ST.NO.
Q61P POWER RUN ERR RUN PRM RUN PRM RUN PRM RUN PRM
INIT COM.ERR MODE D LINK MODE D LINK MODE D LINK MODE D LINK
OPEN 100M SD RD EXT.PW SD RD SD RD SD RD
SD RD ERR. ERR. ERR. ERR.
× 100 10 1 × 100 10 1
STATION NO.
X10
0 0
USB USB
1 1
X1 2 2
3 3
MODE
4 4
PULL 5 5
6 6
7 7
EXT.PW 8 8
NC
1 9 9
10BASE-T/100BASE-TX +24V DA
2 A A
3 B B
24G DB 4 C C
5 D D
DG 6
(FG) E E
7
F F
DA DG +24V 24G
DB SLD (FG)
NC
1 3 5 7 9 11 13 15 17 19 21 23 25 27
DA DG +24V 24G
2 4 6 8 10 12 14 16 18 20 22 24 26
DB SLD
(FG)
After
Generic/safety program
USB
13
Programmable Automation Controller
■■System configuration
Safety CPU Simple motion module
R□SFCPU-SET RD77GF
MR-J4-GF-RJ MR-D30
*For detailed information, please refer to "Servo Amplifiers & Motors MELSERVO-J4 Catalog (L(NA)03058)".
IEC/EN 61800-5-2:
Safety level
2007 function
STO (Safe torque off)
SS1 (Safe stop 1)
SS2 (Safe stop 2)*4
Category 4/PL e,
SOS (Safe operating stop)*4
SIL 3
SLS (Safely-limited speed)*5
SBC (Safe brake control)
SSM (Safe speed monitor)*5
*4. SS2 and SOS are achievable with the use of the servo motor with functional safety unit.
*5. The safety level would be Category 3/PL d, SIL 2 when the servo motor with functional safety is not used.
14
Common engineering platform realizes efficient engineering
■■GX Works3
In GX Works3, generic and safety programs are included in the same project folder. GX Works3 is highly adaptable to projects in
different countries through its multiple language features.
Module list
Simply drag & drop modules directly into the module
configuration
Navigation window
Manage program files for safety control on GX Works3
Module configuration
Easily parameterize each module directly from the
configuration editor
Safety FB list
FB name Function Description
M+SF_2HAND2_R Two hand switch Type II Provides the two-hand control functionality.
M+SF_2HAND3_R Two hand switch Type III Provides the two-hand control functionality. (Fixed specified time difference is 500 ms.)
M+SF_EDM_R External device monitor Controls a safety output and monitors controlled actuators, e.g. subsequent contractors.
M+SF_ENBLSW_R Enable switch Evaluates the signals of an enable switch with three positions.
M+SF_ESPE_R Light Curtain (ESPE) Safety-related FB for monitoring electro-sensitive protective equipment (ESPE).
Safety-related FB for monitoring an emergency stop switch. This FB can be used for
M+SF_ESTOP_R Emergency Stop
emergency switch off functionality (stop category 0).
Controls an entrance to a hazardous area via an interlocking guard with guard locking ("four
M+SF_GLOCK_R Guard Lock and Interlocking
state interlocking").
Monitors the relevant safety guard. There are two independent input parameters for two
M+SF_GMON_R Guard Monitoring switches at the safety guard coupled with a time difference (Monitoring Time) for closing
the guard.
M+SF_MODSEL_R Mode Selector Selects the system operation mode, such as manual, automatic, and semi-automatic, etc.
Control of a safety output with a signal from the functional application and a safety signal
M+SF_OUTC_R Output Control
with optional startup inhibits.
Muting is the intended suppression of the safety function. (e.g., light barriers) In this FB,
M+SF_MUTE2_R Muting with 2 sensors
parallel muting with two muting sensors is specified.
M+SF_MUTEP_R Parallel muting Parallel muting with four muting sensors is specified.
M+SF_MUTES_R Sequential muting Sequential muting with four muting sensors is specified.
Detects, for example, the loss of the sensing unit detection capability, the response time
M+SF_TSSEN_R Testable safety sensor exceeding that specified, and static ON signal in signal-channel sensors systems. It can
be used for external testable safety sensors.
Converts two equivalent bit inputs (both NO or NC) to one bit with discrepancy time
M+SF_EQUI_R Double input (NC + NC or NO + NO)
monitoring. This FB output shows the result of the evaluation of both channels.
Converts two antivalent*1 bit inputs (NO/NC pair) to one bit output with discrepancy time
M+SF_ANTI_R Double input (NO + NC)
monitoring. This FB output shows the result of the evaluation of both channels.
*1. "Antivalent" means that during normal operation, the two inputs are in opposite states at the same time. This is sometimes called "complementary" or "non-equivalent".
15
Programmable Automation Controller
……
16
Easier troubleshooting reducing downtime
The MELSEC iQ-R Series includes various maintenance features:
CC-Link IE Field
System monitor configuration
Event history
17
Programmable Automation Controller
Application example
Safety CPU
Simple motion module
Assembly line
Error occurs at Process 2. Stations at Process 1 and Process 2 are made to stop with an emergency.
Station at Process n keeps operation.
18
Wiring/parameter setting example
■■Wiring example*1
Wiring example of light curtain, laser scanner, and contactor.
Item Setting
Transmission interval monitoring time 35 (Setting range: 4…1000 ms) (Default: 35)
Wiring selection of input (X0, X1, X8…X1F) 0: No used (Default) 1: Double wiring (NC/NC) 2: Single wiring
Wiring selection of input (X2…X7) 0: No used (Default) 1: Double wiring (NC/NC) 2: Single wiring
Input response time (X0…X1F)*2 0: 1 ms (Default) 1: 5 ms 2: 10 ms 3: 20 ms 4: 50 ms
Double input discrepancy detection setting (X0, X1, X8…X1F) 0: Detect (Default) 1: Do not detect
Double input discrepancy detection setting (X2, X3) (X4, X5) (X6, X7) 0: Detect (Default) 1: Do not detect
Double input discrepancy detection type (X0, X1, X8…X1F) 0: Discrepancy detection time specified (Default)
1: Discrepancy detection time not specified
Double input discrepancy detection type (X2, X3) (X4, X5) (X6, X7) 0: Discrepancy detection time specified (Default)
1: Discrepancy detection time not specified
Auto recovery function at occurrence of a double input discrepancy error 0: Not used (Default) 1: Used
Double input discrepancy detection time (X0, X1, X8…X1F)*3 1 (Setting range: 1…6000 (Default: 1)) x 10 ms
Double input discrepancy detection time (X2, X3)*3 10 (Setting range: 1…6000 (Default: 1)) x 10 ms
Double input discrepancy detection time (X4, X5) (X6, X7)*3 2 (Setting range: 1…6000 (Default: 1)) x 10 ms
Input dark test execution setting (X0, X1, X4…X1F) 0: Execute (Default) 1: Not execute
Input dark test execution setting (X2, X3) 0: Execute (Default) 1: Not execute
Input dark test pulse OFF time*2 0: 400 μs (Default) 1: 1 ms 2: 2 ms
Number of pulse output for input dark test 0: 1 time (Default) 1: 2 times 2: 3 times
Extension 1_Wiring selection of output (Y0, Y1) 0: No use (Default) 1: Double wiring (Source/Source) 2: Single wiring
Extension 1_Wiring selection of output (Y2…Y7) 0: No use (Default) 1: Double wiring (Source/Source) 2: Single wiring
Extension 1_Output dark test execution setting (Y0, Y1) 0: Execute (Default) 1: Not execute
Extension 1_Output dark test execution setting (Y2…Y7) 0: Execute (Default) 1: Not execute
Extension 1_Output dark test pulse OFF time (Y0, Y1, Y2…Y7)*2 0: 400 μs (Default) 1: 1 ms 2: 2 ms
Extension 1_Number of pulse output for output dark test 0: 1 time (Default) 1: 2 times 2: 3 times
*1. For details of the wiring example and parameter setting example, refer to "MELSEC iQ-R Safety Application Guide (SH-081538ENG)".
*2. Adjust the values of input response time, input dark test pulse off time, and output dark test pulse off time according to the installation environment and wiring length.
*3. Set "Double input discrepancy detection time" to "100 ms" for the mechanical switch and "20 ms" for the sensor input as a guideline.
19
Programmable Automation Controller
Programming example
The MELSEC iQ-R Series is easily programmed using GX Works3. Both safety and generic programs can be created in a
project. Safety programs are created with ladder diagrams (including safety FBs). Fixed scan is specified as the program
execution type and the program is created using safety devices, generic/safety shared labels, and safety FBs.
* For details of the programming example, refer to "MELSEC iQ-R Safety Application Guide (SH-081538ENG)".
Safety FB*1
Safety FBs are units of ladder blocks repeatedly used in creating
a safety program. Efficient engineering is realized, reducing
programming mistakes
Low count and compact safety remote I/O modules have been added to the existing CC-Link IE Field Network safety remote I/O
modules. Three types of compact remote I/Os are available, offering flexibility and reducing hardware costs.
100 mm
50 mm
90 mm 142 mm
113 mm 68 mm
20
MELSEC iQ-R Series specifications
21
Safety Programmable Controller
MELSEC-QS Series
MELSEC-Q Series
USB
CC-Link IE Control Network module (QJ71GP21-SX) or
MELSECNET/H module
(MELSEC-Q Series modules: QJ71LP21-25, QJ71BR11, etc.)
NC Y0+ NC Y0- NC Y1+ NC Y1- NC Y2+ NC Y2- NC Y3+ NC Y3- NC NC Y0+ NC Y0- NC Y1+ NC Y1- NC Y2+ NC Y2- NC Y3+ NC Y3- NC
NC NC 1 3 5 7 9 11 13 15 17 19 21 23 25 27
DA DG +24V 24G
NC COM- I/O 24V I/O 24G NC COM- I/O 24V I/O 24G 2 4 6 8 10 12 14 16 18 20 22 24 26
DB SLD
(FG)
*2. Number of input points: 8 points (double wiring), No. of output points: 4 points (source + sink type)
*3. Number of input points: 8 points (double wiring)
*4. Number of output points: 4 points (source + sink type)
22
Reducing costs while increasing diagnostic capabilities and
system flexibility
The MELSEC-QS Series solves the complicated wiring and time-consuming troubleshooting issues associated with previous
safety relay systems.
(4)
Difficult to
identify errors
Safety relay panel
Before
After (4)
Quick
and easy
identification
of errors
(1)
DA DG +24V 24G
DB SLD (FG)
NC
Simplified wiring
with a single cable.
Distributed safety
remote stations MELSEC-Q Series
MELSEC-QS Series
MELSECNET/H
Ethernet
23
Safety Programmable Controller
■■GX Developer
••Use GX Developer to start up MELSEC-QS Series safety control systems (programming, monitoring, diagnosis, and
debugging). GX Developer can configure CC-Link Safety, CC-Link IE Field Network and safety remote station parameters.*1
*1. GX Works2 is necessary to configure CC-Link IE Field Network settings when using generic programmable controllers.
Safety FB list
FB name Function Description
F+2HAND2 Two hand switch Type II Provides the two-hand control functionality.
Provides the two-hand control functionality. (Fixed specified time difference is 500
F+2HAND3 Two hand switch Type III
ms.)
Controls a safety output and monitors controlled actuators, e.g. subsequent
F+EDM External device monitor
contractors.
F+ENBLSW Enable switch Evaluates the signals of an enable switch with three positions.
F+ESPE Light Curtain (ESPE) Safety-related FB for monitoring electro-sensitive protective equipment (ESPE).
Safety-related FB for monitoring an emergency stop switch. This FB can be used for
F+ESTOP Emergency Stop
emergency switch off functionality (stop category 0).
Controls an entrance to a hazardous area via an interlocking guard with guard
F+GLOCK Guard Lock and Interlocking
locking ("four state interlocking").
Monitors the relevant safety guard. There are two independent input parameters for
F+GMON Guard Monitoring two switches at the safety guard coupled with a time difference (Monitoring Time) for
closing the guard.
Selects the system operation mode, such as manual, automatic, and semi-automatic,
F+MODSEL Mode Selector
etc.
Muting is the intended suppression of the safety function. (e.g., light barriers) In this
F+MUTE2 Muting with 2 sensors
FB, parallel muting with two muting sensors is specified.
F+MUTEP Parallel muting Parallel muting with four muting sensors is specified.
F+MUTES Sequential muting Sequential muting with four muting sensors is specified.
Control of a safety output with a signal from the functional application and a safety
F+OUTC Output control
signal with optional startup inhibits.
Detects, for example, the loss of the sensing unit detection capability, the response
F+TSSEN Testable safety sensor time exceeding that specified, and static ON signal in signal-channel sensors
systems. It can be used for external testable safety sensors.
Converts two equivalent bit inputs (both NO or NC) to one bit with discrepancy time
F+EQUI Dual input (NC + NC or NO + NO)
monitoring. This FB output shows the result of the evaluation of both channels.
Converts two antivalent*3 bit inputs (NO/NC pair) to one bit output with discrepancy
F+ANTI Dual input (NO + NC)
time monitoring. This FB output shows the result of the evaluation of both channels.
*2. The safety FBs are provided for GX Developer version 8.82L or later. (QS001CPU is supported with the first five digits of serial number "11042" or later.)
*3. "Antivalent" means that during normal operation, the two inputs are in opposite states at the same time. This is sometimes called "complementary" or "non-equivalent".
24
Easy error/failure troubleshooting
Debug functions
Debug functions (device test, write during RUN, etc.) are available in test mode.
GX Developer
TEST mode:
TEST mode Used at system startup and during
maintenance
Program, parameter, and
device data changes
allowed
SAFETY mode:
SAFETY mode Used during actual safety system
operation
Program, parameter, and
device data changes
prohibited
25
Safety Programmable Controller
Application example
MELSECNET/H
Ethernet
MELSEC-Q
Series
MELSEC-QS Series
(safety control)
NC NC
NC COM- I/O 24V I/O 24G NC COM- I/O 24V I/O 24G
Emergency
stop switch
Enable button
Light
curtain
Area sensor
26
Wiring/parameter setting example
■■Wiring example*1
Wiring example of an emergency stop switch, a two-hand operation switch, and two contactors.
Remote (4)
QS0J65BTB2-12DT (4)
(Link ID=1, Station No.1) Double safety output:
Connect the close contact Connect two safety contactors from
1 COM− 37 DA
of the contactor between 2 X0 38 DB
one output Y
the input terminal and test 3 T0 39 DG
Item Setting
Time of noise removal filter X2, X3*2 1 ms, 5 ms, 10 ms, 20 ms, 50 ms
Time of noise removal filter X4, X5*2 1 ms, 5 ms, 10 ms, 20 ms, 50 ms
Time of noise removal filter X8, X9*2 1 ms, 5 ms, 10 ms, 20 ms, 50 ms
Time of noise removal filter XA, XB*2 1 ms, 5 ms, 10 ms, 20 ms, 50 ms
Double input discrepancy detection time X2, X3*2 100 ms (Setting range: 20 ms…60 s*3)
Double input discrepancy detection time X4, X5*2 100 ms (Setting range: 20 ms…60 s*3)
Double input discrepancy detection time X8, X9*2 100 ms (Setting range: 20 ms…60 s*3)
Double input discrepancy detection time XA, XB*2 100 ms (Setting range: 20 ms…60 s*3)
Input dark test selection X2, X3 Execute, Not execute, X2*4: Execute X3*4: Not execute, X2*4: Not execute X3*4: Execute
Input dark test selection X4, X5 Execute, Not execute, X4*4: Execute X5*4: Not execute, X4*4: Not execute X5*4: Execute
Input dark test selection X8, X9 Execute, Not execute, X8*4: Execute X9*4: Not execute, X8*4: Not execute X9*4: Execute
Input dark test selection XA, XB Execute, Not execute, XA*4: Execute XB*4: Not execute, XA*4: Not execute XB*4: Execute
Input dark test pulse OFF time 400 μs, 1 ms, 2 ms
Method of wiring of output Y2 No use, Double wiring (source + sink), Double wiring (source + source)
Output dark test selection Y2 Execute, Not execute
Output dark test pulse OFF time Y2 400 μs, 1 ms, 2 ms
Double input/single input selection X2, X3*4 Double input, X2-X3: Single input, X2: Single input X3: No use, X2: No use X3: Single input
Double input/single input selection X4, X5*4 Double input, X4-X5: Single input, X4: Single input X5: No use, X4: No use X5: Single input
Double input/single input selection X8, X9*4 Double input, X8-X9: Single input, X8: Single input X9: No use, X8: No use X9: Single input
Double input/single input selection XA, XB*4 Double input, XA-XB: Single input, XA: Single input XB: No use, XA: No use XB: Single input
Auto RTN Func to detect double input mismatch*4 Invalid, Valid
*1. For details of the wiring example and parameter setting example, refer to "Safety Application Guide (SH-080613ENG)".
*2. Adjust "Time of noise removal filter", "Input dark test pulse OFF time", and "Output dark test pulse OFF time" according to the installation environment and wiring length. Set "Double input discrepancy detection time"
to "100 ms" for the mechanical switch and "20 ms" for the sensor input as a guideline.
*3. The setting range is 20 ms to 500 ms for QS0J65BTB2-12DT models prior to module technical version B. The range is 20 ms to 60 s for subsequent models.
*4. The setting is only possible for QS0J65BTB2-12DT units of technical version D or later, and QS0J65BTS2-8D units of technical version B or later.
27
Safety Programmable Controller
Programming example
The MELSEC-QS Series is programmed using GX Developer. Safety programs are created with ladder diagrams (including
safety FBs). Safety devices (input/output) can be highlighted in color set by user.
* For details of the programming example, refer to "Safety Application Guide (SH-080613ENG)".
28
Safety power supply module specifications
Item QS061P‐A1 QS061P‐A2
100…120 +10% 200…240 +10%
Input power supply (V AC)
(85…132) −15% (170…264) −15%
Input frequency 50/60 Hz ±5%
Weight (kg) 0.40
External dimensions (H x W x D, mm) 98 x 55.2 x 115
Specifications for CC-Link IE Field Network master/local module (with Safety Communication Functions)
Item QS0J71GF11-T2
Max. number of connectable stations Generic station (non-safety): 121 (1 master plus 120 slave stations)
per network*1 Safety station: 32 (1 master plus 31 slave stations)
Weight (kg) 0.18
External dimensions (H x W x D, mm) 98 x 27.4 x 115
*1. For combining generic and safety stations, up to 121 stations can be connected per network. (Generic or safety station can be master station.)
29
Safety Controller
MELSEC-WS Series
A1 A2
MS
CV
LINE
CPU3 EFI
USB/RS-232 conversion cable 1 2
WS0-C20M8U
LINE
A PRE B ANEXT B
A EFI1 B A EFI2 B
*2. No. of input points: 8 points (single wiring), No. of output points: 4 points (single wiring)
*3. No. of input points: 8 points (single wiring)
*4. Safety relay output: 4 points
The MELSEC-WS Series was developed and manufactured by SICK AG. SICK is a German
supplier of safety solutions. SICK designs and manufactures a broad range of safety products
including industrial-use sensors and automatic identification systems.
* General specifications and product guarantee conditions for co-branded products may vary from those of general MELSEC products.
For more information, please refer to the relevant product manuals or contact your local Mitsubishi Electric sales office/representative.
SICK AG http://www.sick.com/
30
Flexible extensibility
••Up to 12 safety input and I/O modules, 4 safety relay 22.5 mm
MS
LINE
CPU3 EFI
A PRE B ANEXT B
A EFI1 B A EFI2 B
12 stations
Max. 32 stations
Max. 1000 m
(Between stations) Flexi Line*1
A1 A2 A1 A2 A1 A2 A1 A2
MS MS MS MS
CV CV CV CV
1 2 1 2 1 2 1 2
A1 A2 A1 A2 A1 A2 A1 A2
MS MS MS MS
CV CV CV CV
1 2 1 2 1 2 1 2
Max. 4 stations
A EFI1 B A EFI2 B A EFI1 B A EFI2 B A EFI1 B A EFI2 B A EFI1 B A EFI2 B
MS MS MS MS
CV CV CV CV
1 2 1 2 1 2 1 2
A1 A2 A1 A2 A1 A2 A1 A2
MS MS MS MS
CV CV CV CV
1 2 1 2 1 2 1 2
*1. Flexi Line is supported by WS0-CPU3 only and Flexi Link is supported by WS0-CPU1 and WS0-CPU3 only. For details about network specifications, refer to page 11.
31
Safety Controller
■■Configuration
Hardware configuration can be easily and quickly done using a wide range of elements.
*1. For details on how to obtain the tool, please contact your local Mitsubishi Electric
sales office or representative.
*2. Connecting parameters of major safety equipment, such as emergency stop (3) Select desired safety elements
switches, safety door switches and light curtains, are expressed by an icon. and connect them to the I/O terminal
Make settings simply by drag-and-drop decision. Elements for Safety devices
of Mitsubishi’s partners are also available. Please contact your local Mitsubishi
representative.
(3) Connect the (2) Internal module status (4) Error details
terminal of the label
to that of the function
block
32
■■Report ■■I/O matrix
The wiring diagram for I/O modules can be automatically The relation of inputs and outputs can be displayed as a
created. Report such as error diagnosis can be created, matrix.
printed, and saved as PDF.
■■Data recorder
ON/OFF status of safety input signal and safety output signal processed by the safety controller can be stored.*1 Results
recorded on the Setting and Monitoring Tool can also be viewed on the computer to utilize for troubleshooting.
*1. Available when a CPU module with firmware version of V2.01 (revision 2.XX) or later and a Setting and Monitoring Tool of V1.7.0 or later are used together.
33
Safety Controller
Application example
■■Press machine
The MELSEC-WS Series secures safety of standalone devices such as press machine. The MELSEC-WS Series are compact
controllers with flexible features such as extendable I/Os, safety communication between CPUs, communication with a generic
programmable controller, and fast shut off function realizing faster response times.
Light curtain
Ethernet
Safety Controller
MELSEC-WS
Series
••Incorporating the MELSEC-WS Series into the existing system can easily add safety functions.
34
Wiring/parameter setting example
■■Wiring example
Wiring example of light curtain, emergency stop switch, and safety contactor.
* For details of the wiring example, refer to "Safety Controller User's Manual (SH-080855ENG)".
24 V DC
+ −
Optical transmitter
Light 24 V DC
curtain
0V
(Synchronization negative)
FG
(Synchronization positive)
Emergency
stop
switch
A1 A2 X1 X2 A1 A2 X1 X2 A1 A2
Optical receiver
I1 I2 I3 I4 I1 I2 I3 I4
(Synchronization positive)
(Synchronization negative) WS0-CPU0 WS0-XTIO WS0-XTIO
24 V DC
OSSD1 I5 I6 I7 I8 I5 I6 I7 I8
FG
OSSD2
Q1 Q2 Q3 Q4 Q1 Q2 Q3 Q4
0V
L1
L2
L3
+
Connect the OSSD1 and OSSD2 (control outputs) of the light curtain to Contactor
the I1 to I8 (input) terminals −
Connect the forced open contact (auxiliary close contact when the
main contact is welded) of the contactor between the I1 to I8 (input)
terminals and the X1 and X2 (test output) terminals
L1
L2
Connect an emergency stop switch (with dual-channel equivalent L3
switching contacts for direct operation) between the I1 to I8 (input)
terminals and the X1 and X2 (test pulse output) terminals
Safety element
When wiring the safety element, click the check box
ON-OFF filter
Enabling the ON-OFF filter (or OFF-ON filter) can prevent influences by minor disturbance of
signals generating at turning on and off of element
Filter time
Filter time can be set in the range of 8 to 10000 ms
(WS0-XTIO and WS0-XTDI should be V 3.10 or later)
35
Safety Controller
Programming example
The MELSEC-WS Series is easily programmed using the Setting and Monitoring Tool. By utilizing function blocks, logic can be
created. Simply drag & drop input and output safety device labels and function blocks, then wire function block terminal and label
to create a safety program. Diagnosis bit and CPU marker can be also used. Parameters and programs written from the Setting
and Monitoring Tool are stored in the memory plug for the CPU module, without having to upload parameters and programs after
replacing the CPU module.
Function
Input safety device label block Output safety device label
36
MELSEC-WS Series specifications
37
Safety Drive Products
* For details of inverters, please refer to FR-A800 Series catalog (L (NA) 06075ENG), FR-F800 Series catalog (L (NA) 06085ENG), FR-E700 Series catalog (L (NA)
06051ENG), and FR-D700 Series catalog (L (NA) 06055ENG).
■■System configuration
Molded-case
Inverter circuit breaker
Compact output (MCCB)
safety remote I/O*1 shutoff Magnetic contactor
for preventing
unexpected start is no
……
Error detection/alarm longer required
Inverter*2
(FR-A800) Magnetic contactor (MC)* 3
Motor (SF-PR)
38
Industrial robot MELFA FR Series
■■System configuration
Door Emergency
Robot Robot
switch stop switch Area sensor Robot
safety option controller
Light curtain
Enable button
39
Support
Online e-learning
An extensive library of e-learning courses covering the factory automation product range has been prepared.
Courses from beginner to advanced levels of difficulty are available in various languages.
◼ Beginner level
Designed for newcomers to Mitsubishi Electric Factory
Automation products gaining a background of the
fundamentals and an overview of various products
related to the course.
40
Innovative next-generation, e-Manual
The e-Manual viewer is a next-generation digital manual offered by Mitsubishi Electric that consolidates all
manuals into an easy-to-use package with various useful features integrated into the viewer. The e-Manual is
modeled around a centralized database allowing multiple manuals to be cross-searched at once, further reducing
the time for reading individual product manuals when setting up a control system.
iOS Android™
Version 8.1 or later Version 4.3/4.4/5.0
◼ Supported versions
OS OS version Model
Apple iPad 2, iPad (3rd generation), iPad (4th generation), iPad Air, iPad Air 2,
iOS iOS 8.1 or later
iPad mini, iPad mini 2, iPad mini 3, iPad mini 4, iPad Pro (12.9 inch), iPad Pro (9.7 inch)
Android™ Android™ 4.3/4.4/5.0 ASUS Nexus7™ (2013)*1
*1. When using a tablet not listed above, 7-inch (resolution of 1920 x 1200 dots (WUXGA)) or better is recommended.
41
Support
CLPA-Europe CT
(Germany)
CLPA-Korea CT
(Seoul)
CLPA-North America CT
CLPA-China CT CLPA Headquarters CT (Vernon Hills, Illinois, USA)
(Shanghai) (Nagoya, Japan)
CLPA-Americas
(Mexico office)
CLPA-Taiwan (Tlalnepantla)
CLPA-Turkey (Taipei)
(Istanbul)
CC-Link
CLPA-India Promotion Center Thailand
(Gurgaon) (Bangkok)
42
Extensive global support coverage
providing expert help whenever needed
■ Global FA centers
MITSUBISHI ELECTRIC
CORPORATION
43
Product list
44
Safety controller MELSEC-WS Series
Product name Model Outline
CPU WS0-CPU000200 (WS0-CPU0)*1 Program capacity: 255 FBs, Scan cycle: 4 ms, RS-232 Interface
EFI-equipped (EFI is the communication interface for setting SICK's safety products.)
CPU (with EFI) WS0-CPU130202 (WS0-CPU1)*1
Flexi Link with EFI RS-232 Interface
EFI-equipped (EFI is the communication interface for setting SICK's safety products.)
CPU (with EFI, Flexi Line) WS0-CPU320202 (WS0-CPU3)*1
Flexi Link with EFI Flexi Line with EFI RS-232 Interface, USB Interface
WS0-MPL000201 (WS0-MPL0)*1 For storing CPU parameters and programs (required) (for WS0-CPU0/WS0-CPU1)
Memory plug for CPU
WS0-MPL100201 (WS0-MPL1)*1 For storing CPU parameters and programs (required) (for WS0-CPU3)
Safety input WS0-XTDI80202 (WS0-XTDI)*1 Safety input: 8 points (single input), Spring clamp terminal block
Safety input: 8 points (single input), Safety output: 4 points (single output)
Safety I/O combined WS0-XTIO84202 (WS0-XTIO)*1 Output current: max. 2 A, Spring clamp terminal block, Fast shut off function (response of 8
ms)
Safety relay output WS0-4RO4002 (WS0-4RO)*1 Safety output: safety relay output 4 points Switching current: max. 6 A
WS0-C20M8U USB/RS-232 conversion cable for PC-CPU connection (2 m)
USB/RS-232 conversion cable
WS0-UC-232A*2 USB/RS-232 conversion cable (35 cm)
RS-232 cable connecting to CPU WS0-C20R2 RS-232 cable for PC-CPU connection (2 m)
For CC-Link communication (generic communication) Remote device station,
CC-Link interface WS0-GCC100202 (WS0-GCC1)*1
CC-Link version 1.10
Ethernet interface WS0-GETH00200 (WS0-GETH)*1 For Ethernet TCP/IP connection (generic communication)
Screw-in replacement terminal block WS0-TBS4 Screw-in replacement terminal block (4 pcs)
Spring clamp replacement terminal
WS0-TBC4 Spring clamp replacement terminal block (4 pcs)
block
Setting and Monitoring Tool SW1DNN-WS0ADR-B*3 Setting and monitoring tool for safety controller
*1. Abbreviated product model name is shown in ( ) for this catalog. Please notify the full model name in the upper product list when contacting local Mitsubishi sales office or representative.
*2. Use this in combination with WS0-C20R2.
*3. For the acquisition of Setting and Monitoring Tool, please contact your local Mitsubishi sales office or representative.
45
Compliance with international quality assurance standards
All of Mitsubishi Electric's FA products have acquired the international quality assurance "ISO9001" and
environment management system standard "ISO14001" certification. Mitsubishi Electric's products also comply
with various safety standards, including UL standards.
*For jointly developed and partner products, guaranteed quality standards may differ. Please refer to the product manuals for details.
Safety Standards
Council Directive of the Underwriters Laboratories
CE : UL :
European Communities Listing
46
Automation solutions
Mitsubishi Electric offers a wide range of automation equipment from PLCs and HMIs to
CNC and EDM machines.
47
Country/Region Sales office Tel/Fax
USA MITSUBISHI ELECTRIC AUTOMATION, INC. Tel : +1-847-478-2100
500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A. Fax : +1-847-478-2253
Mexico MITSUBISHI ELECTRIC AUTOMATION, INC. Mexico Branch Tel : +52-55-3067-7512
Boulevard Miguel de Cervantes Saavedra 301, Torre Norte Piso 5, Ampliacion Granada,
Miguel Hidalgo, Ciudad de Mexico, Mexico, C.P.115200
Brazil MITSUBISHI ELECTRIC DO BRASIL COMERCIO E SERVICOS LTDA. Tel : +55-11-4689-3000
Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, Brasil Fax : +55-11-4689-3016
Germany MITSUBISHI ELECTRIC EUROPE B.V. German Branch Tel : +49-2102-486-0
Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany Fax : +49-2102-486-7780
UK MITSUBISHI ELECTRIC EUROPE B.V. UK Branch Tel : +44-1707-28-8780
Travellers Lane, UK-Hatfield, Hertfordshire, AL10 8XB, U.K. Fax : +44-1707-27-8695
Ireland MITSUBISHI ELECTRIC EUROPE B.V. Irish Branch Tel : +353-1-4198800
Westgate Business Park, Ballymount, Dublin 24, Ireland Fax : +353-1-4198890
Italy MITSUBISHI ELECTRIC EUROPE B.V. Italian Branch Tel : +39-039-60531
Centro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, 20864 Agrate Brianza (MB), Italy Fax : +39-039-6053-312
Spain MITSUBISHI ELECTRIC EUROPE, B.V. Spanish Branch Tel : +34-935-65-3131
Carretera de Rubi, 76-80-Apdo. 420, E-08190 Sant Cugat del Valles (Barcelona), Spain Fax : +34-935-89-1579
France MITSUBISHI ELECTRIC EUROPE B.V. French Branch Tel : +33-1-55-68-55-68
25, Boulevard des Bouvets, 92741 Nanterre Cedex, France Fax : +33-1-55-68-57-57
Czech Republic MITSUBISHI ELECTRIC EUROPE B.V. Czech Branch, Prague Office Tel : +420-255-719-200
Pekarska 621/7, 155 00 Praha 5, Czech Republic
Poland MITSUBISHI ELECTRIC EUROPE B.V. Polish Branch Tel : +48-12-347-65-00
ul. Krakowska 48, 32-083 Balice, Poland
Sweden MITSUBISHI ELECTRIC EUROPE B.V. (Scandinavia) Tel : +46-8-625-10-00
Hedvig Mollersgata 6, 223 55 Lund, Sweden Fax : +46-46-39-70-18
Russia MITSUBISHI ELECTRIC (RUSSIA) LLC St. Petersburg Branch Tel : +7-812-633-3497
Piskarevsky pr. 2, bld 2, lit “Sch”, BC “Benua”, office 720; 195027 St. Petersburg, Russia Fax : +7-812-633-3499
Turkey MITSUBISHI ELECTRIC TURKEY A.S Umraniye Branch Tel : +90-216-526-3990
Serifali Mahallesi Nutuk Sokak No:5, TR-34775 Umraniye/Istanbul, Turkey Fax : +90-216-526-3995
UAE MITSUBISHI ELECTRIC EUROPE B.V. Dubai Branch Tel : +971-4-3724716
Dubai Silicon Oasis, P.O.BOX 341241, Dubai, U.A.E. Fax : +971-4-3724721
South Africa ADROIT TECHNOLOGIES Tel : +27-11-658-8100
20 Waterford Office Park, 189 Witkoppen Road, Fourways, South Africa Fax : +27-11-658-8101
China MITSUBISHI ELECTRIC AUTOMATION (CHINA) LTD. Tel : +86-21-2322-3030
Mitsubishi Electric Automation Center, No.1386 Hongqiao Road, Shanghai, China Fax : +86-21-2322-3000
Taiwan SETSUYO ENTERPRISE CO., LTD. Tel : +886-2-2299-2499
6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan Fax : +886-2-2299-2509
Korea MITSUBISHI ELECTRIC AUTOMATION KOREA CO., LTD. Tel : +82-2-3660-9569
7F to 9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, Seoul 07528, Korea Fax : +82-2-3664-8372
Singapore MITSUBISHI ELECTRIC ASIA PTE. LTD. Tel : +65-6473-2308
307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943 Fax : +65-6476-7439
Thailand MITSUBISHI ELECTRIC FACTORY AUTOMATION (THAILAND) CO., LTD. Tel : +66-2682-6522
12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Fax : +66-2682-6020
Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand
Vietnam MITSUBISHI ELECTRIC VIETNAM COMPANY LIMITED Tel : +84-28-3910-5945
Unit 01-04, 10th Floor, Vincom Center, 72 Le Thanh Ton Street, District 1, Ho Chi Minh City, Vietnam Fax : +84-28-3910-5947
Indonesia PT. MITSUBISHI ELECTRIC INDONESIA Tel : +62-21-31926461
Gedung Jaya 8th Floor, JL. MH. Thamrin No.12, Jakarta Pusat 10340, Indonesia Fax : +62-21-31923942
India MITSUBISHI ELECTRIC INDIA PVT. LTD. Pune Branch Tel : +91-20-2710-2000
Emerald House, EL-3, J Block, M.I.D.C., Bhosari, Pune-411026, Maharashtra, India Fax : +91-20-2710-2100
Australia MITSUBISHI ELECTRIC AUSTRALIA PTY. LTD. Tel : +61-2-9684-7777
348 Victoria Road, P.O. Box 11, Rydalmere, N.S.W 2116, Australia Fax : +61-2-9684-7245
Mitsubishi Electric Corporation Nagoya Works is a factory certified for ISO 14001 (standards for environmental
management systems) and ISO 9001 (standards for quality assurance management systems).
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
www.MitsubishiElectric.com