HVAC Solutions

Energy efficient and reliable solutions


BRAND PROMISE

For more than a century, Westinghouse has consistently provided innovative,


reliable, high-quality products and customer service. It’s a combination of
groundbreaking technology and rock-solid dependability that’s made us one of
the world’s most trusted brands.

From outdoor portable generators that provide power for your home, work and
play moments, to high-definition TVs that are setting new standards for per-
formance, we’re constantly developing advanced products, rigorously testing
them to make sure they work time after time, day after day.

When you see the W, you know you’re getting a product packed with features
that make your life easier, while still being easy to use. A product that has all
the latest thinking, while providing years of value.

Innovation You Can Be Sure Of.

From a company that always puts you first.


CONTENTS
1. Light Commercial Air Conditioners
1.1 Technology..........................................................................................................................................................01
1.2 Cassette air conditioners....................................................................................................................................08
1.2.1 Briefing the Cassette models.......................................................................................................................08
1.2.2 Specification sheet......................................................................................................................................09
1.3 Ducted type air conditioners...............................................................................................................................12
1.3.1 Briefing the Ducted type.............................................................................................................................12
1.3.2 Specification sheet......................................................................................................................................13

2. Commercial Air Conditioning


2.1 High capacity Ducted type.................................................................................................................................17
2.1.1 Briefing of the capacity ranges...................................................................................................................17
2.1.2 Specification sheet......................................................................................................................................18
2.2 Roof top package...............................................................................................................................................24
2.2.1 Briefing of the capacity and types...............................................................................................................24
2.2.2 Specification sheet for the models..............................................................................................................25

3. VRF
3.1 VRF Technology..................................................................................................................................................26
3.2 Multi W5 VRF.......................................................................................................................................................29
3.2.1 Specification details.....................................................................................................................................33

4. Photovoltaic VRF
4.1 Photo voltaic technology....................................................................................................................................35
4.2 Components of the Photo voltaic system...........................................................................................................35
4.3 Working of the photo voltaic system..................................................................................................................43
4.4 Multi W5 Solar.....................................................................................................................................................45
4.4.1 Multi W5 Solar functionality..........................................................................................................................45
4.4.2 Multi W5 Solar Specification.......................................................................................................................46
4.5 Multi W5 Solar Mini............................................................................................................................................47
4.5.1 Multi W5 Solar Mini functionality...................................................................................................................47
4.5.2 Multi W5 Solar Specification.......................................................................................................................48

5. VRF Indoor Unit


5.1 Indoor Units........................................................................................................................................................49
5.1.1 Types of indoor units...................................................................................................................................50
Westinghouse has consistently provided innovative,
reliable, high-quality products and customer service.
It’s a combination of groundbreaking technology and
rock-solid dependability that’s made us one of the
world’s most trusted brands.
HVAC Solutions
Energy efficient and reliable solutions.
Light Commercial AC Series
Energy efficient and reliable solutions.
Westinghouse Inverter Series
Higher Efficiency & More Energy Saving
Through setting temperature lower limit in cooling or drying mode, and setting temperature upper limit in
heating mode, the system is able to operate in a smaller temperature range so as to achieve energy saving.
Besides, the unit has got the following energy-saving technologies:

4 DC Inverters

The fan motors of IDU and ODU, compressor, and intelligent control are all DC inverters.

The unit adopts high-efficiency


The indoor unit and outdoor DC inverter compressor.
unit adopt high-efficiency DC The high-efficiency DC inverter
brushless motor. The efficiency compressor adopts 180° sine
of such motor will be improved wave space-vector inverter
by over 30% compared with driving technology, so as to
conventional AC motor. realize reliable and stable
Therefore, the energy operation in the frequency as
efficiency of the entire unit will low as 10Hz.
be improved by 15% under low
frequency operation.

180° Sine Wave Technology

Westinghouse advanced DC inverter 180º vector control ensures the stable operation for compressor,
energy-saving up to 20% per year (compared with the common air conditioner).

Light Commercial Air Conditioners | 1


Precise Temperature Control Technology

Westinghouse intelligent inverter control delivers the required capacity according to the load variation from 10% to
120% and maintains the room temperature within 1° of set temperature.

High Efficiency Heat Exchanger

Inner-grooved High Efficiency Copper Tube


The inner-grooved design increases the heat exchange area of
the refrigerant and enhances heat exchanging performance.

Outstanding Performance Slit Type Fin with Anti-corrosive Coating

Outstanding Performance Louver Golden Fins with Anti-corrosive


Coating for both of IDU and ODU.The louver fins enlarge the heat
exchange area and increase the efficiency of the heat exchanger by
5%.The primary materials of Golden Fin is Al-Mn(Aluminum
manganese) anti-rust alloy, which is coated with the Golden
Protection Layer(Components: Epoxy Resin Modified
Acrylic-Silicon free), the anti-corrosive performance in salt-spray
testing is 200%~300% higher than normal fins.

2 | Light Commercial Air Conditioners


Reliable System Design
Intelligent Defrosting
Did you ever feel annoyed when the air conditioner stopped heating because of defrosting? Westinghouse has a
solution . Unit will only start defrosting when it’s necessary. More energy-saving and comfortable to you.

Wide Ambient Operation Range


The unit is suitable for both low ambient temperature area and standard ambient temperature area.

Anti-freezing Protection
If frost of outdoor evaporator is detected by the unit, the compressor will stop for protection

8°C Heating Function


8°C heating function is mainly applied in winter when there is no body in the house. When this function is activated,
the unit will enter stable 8°Cheating to keep the indoor temperature around 8°C. This function will prevent power
wastage and harm to some housewares caused by freezing due to low indoor temperature.

Light Commercial Air Conditioners | 3


I-FEEL Function (Optional)
The mini sensor in the remote controller can sense its
surrounding temperature, and transmit the signal back
to the indoor unit. So the unit can adjust the air flow
volume and temperature accordingly so as to provide
maximum comfort.

Water Full Protection (Optional) Built-in Drainage Water Pump (Optional)


If the water cannot drain out properly for the failure Our unit is equipped with water pump. If the water
of water pump or other causes, this function will be cannot drain out normally, the water pump will start
activated automatically and the unit will stop for pro- drainage automatically to eliminate water leakage
tection when the water in the indoor unit reaches a potential. It can solve the inconvenient drainage
certain level. problem in some projects.

1W Standby Function
The power consumption of the entire unit under standby status is 1W.
Based on standby time of about 67.6 kwh in a year, the power consumption in standby mode of a normal unit is
above 10W, equals to 67.6 kwh per year.

I-demand Function
After entering I-demand function through the function button on the wired control, the output capacity of unit will
be limited. The max powe of the unit cannot exceed 75% of the rated power.

Air Handling Function


Low-temperature Drying Function
In some special cases of low temperature with high humidity, the drying effect is not favorable. The set tempera-
ture in drying of this series is as low as 12ºC and the setting range of stable operation is wider.

Auto Clean (X-FAN)


Do you know that water in IDU will give birth to bacteria which will affect human health? Westinghouse will wipe
out water, caring for your health!

4 | Light Commercial Air Conditioners


Cold Plasma Healthy Function (Optional)
Effective sterilization with more than 90% of bacteria All indoor units can be installed with Westinghouse
killed. cold plasma generator optionally.
Odor Removal
Air nutrition improvement with more negative oxygen
ions.

Filter Cleaning Reminder Function


Filter cleaning reminder function can be set. Usually, the air return inlet’s
filter shall be cleaned regularly. As the operation environment may vary, the
dirty degree of filter is different. Thus, the cleaning cycle may vary. Please
set the cleaning reminder cycle according to actual situation.

Pollution level and corresponding time


Pollution level Accumulated operating time(hour) Pollution level Accumulated operating time(hour) Pollution level Accumulated operating time(hour)

10 5500 20 1400 30 100

11 6000 21 1800 31 200

12 6500 22 2200 32 300

13 7000 23 2600 33 400

14 7500 24 3000 34 500

15 8000 25 3400 35 600

16 8500 26 3800 36 700

17 9000 27 4200 37 800

18 9500 28 4600 38 900

19 10000 29 5000 39 1000

Light Commercial Air Conditioners | 5


Westinghouse
2nd Generation Inverter Series
It is a kind of split system that the outdoor unit can be connected to various indoor unit (duct and cassette type)
with its cooling capacity from 36K to 60K, which is designed for tropical countries.

• High reliable compressor which is capable of operating under extreme condition.


• The outdoor unit is universal and can be matched with duct type and cassette.
• It is capable of fast cooling, fast heating, and can reach user’s set temperature quickly.

Indoor Unit

Duct type Cassette type


• High reliable compressor which is capable of • Drain pump filled as standard with increased lift of
operating under extreme condition. 1100mm.
• The outdoor unit is universal and can be matched • Air return lifting panel can be matched as an
with duct type and cassette. optional panel.
• It is capable of fast cooling, fast heating, and can • Equip with 360° air discharge panel, providing more
reach user’s set temperature quickly. comfortable air supply.
• All kinds of air freshener can be installed in the filter,
such as catechin.

Nominal operating condition (temperature) Operation range (temperature)

Item Outdoor condition Indoor condition Outdoor condition

DB (°C ) WB (°C) DB (°C ) WB (°C) DB (°C )

Cooling 35 - 27 19 18~52

Heating 7 6 20 - -10~24

6 | Light Commercial Air Conditioners


2nd Generation Inverter Series

Capacity Index 36K 48K 60K

Outdoor Unit

Duct

Indoor Unit

Cassette

Light Commercial Air Conditioners | 7


Cassette Type

Low Noise with 3-dimensional Blade High Ceiling Applications


The 36K~60K units are applicable
to a height up to 4.5m

Comfortable Airflow Water Drainage Pump


Air supply in different direction with 30~60 degrees Drain pump fitted as standard with increased lift of
of swing angle ensures even temperature distribu- 1100mm.
tion.

8 | Light Commercial Air Conditioners


Specifications for Cassette Type
Model WC36PNCG31UE WC36RNCG31UE WC42PNCG31UE

Function Cooling & Heating Cooling & Heating Cooling & Heating

Cooling Btu/h 34120 34120 37532


Capacity
Heating Btu/h 40944 40944 42650

SEER/S.C.O.P W/W 6.10/4.00 6.10/4.00 5.6/4.0

Power Supply Ph,V,Hz 1Ph,220-240V,50Hz 3Ph,380-415V,50Hz 1Ph,220-240V,50Hz

Cooling kw 3.20 3.12 3.90


Power input
Heating kw 3.50 3.32 3.80

Cooling A 15.00 5.40 18.10


Current Input
Heating A 16.20 5.80 17.60

Climate Type T1 T1 T1

Indoor Unit

Airflow Volume m3/h 1860 1860 1860

Sound Pressure Level dB(A)(SH/H/M/L) 51/49/46/43 51/49/46/43 51/49/46/43

Outline Dimension mm 840x840x320 840x840x320 840x840x320

Package Dimension mm 963x963x409 963x963x409 963x963x409

Net Weight/ Gross Weight kg 31.0/38.0 31.0/38.0 31.0/38.0

Outdoor Unit

Sound Pressure Level Outdoor dB(A) 63 63 61

Brand Brand GREE GREE GREE


Compressor
Type Type Inverter Inverter Inverter

Refrigerant R410a R410a R410a

Gas mm Ø15.9 Ø15.9 Ø15.9


Piping Connection
Liquid mm Ø9.52 Ø9.52 Ø9.52

Outline Dimension WxHxD mm 1107x440x1100 1107x440x1100 958x412x1349

Package Dimension WxHxD mm 1158x493x1235 1158x493x1235 1043x453x1500

Net Weight/ Gross Weight Outdoor kg 92.0/100.0 98.0/106.0 95.0/105.0

Model WC42RNCG31UE WC48PNCG31UE WC48RNCG31UE WC60RNCG31UE

Function Cooling & Heating Cooling & Heating Cooling & Heating Cooling & Heating

Cooling Btu/h 37532 47768 47768 54592


Capacity
Heating Btu/h 42650 54592 54592 58004

SEER/S.C.O.P W/W 6.1/4.0 6.1/3.8 5.6/3.8 6.1/4.0

Power Supply Ph,V,Hz 3Ph,380-415V,50Hz 1Ph,220-240V,50Hz 3Ph,380-415V,50Hz 3Ph,380-415V,50Hz

Cooling kw 3.90 4.60 5.15 5.70


Power input
Heating kw 3.80 4.50 4.50 4.70

Cooling A 6.70 21.30 8.90 9.80


Current Input
Heating A 6.60 20.80 7.80 8.20

Climate Type T1 T1 T1 T1

Indoor Unit

Airflow Volume m3/h 1860 2300 2300 2400

Sound Pressure Level dB(A)(SH/H/M/L) 51/49/46/43 53/52/47/41 53/52/47/41 55/53/47/41

Outline Dimension mm 840x840x320 910x910x290 910x910x290 910x910x290

Package Dimension mm 963x963x409 1023x993x375 1023x993x375 1023x993x375

Net Weight/ Gross Weight kg 31.0/38.0 43.0/50.0 43.0/50.0 43.0/50.0

Outdoor Unit

Sound Pressure Level Outdoor dB(A) 61 59 59 63

Brand Brand GREE GREE GREE GREE


Compressor
Type Type Inverter Inverter Inverter Inverter

Refrigerant R410a R410a R410a R410a

Gas mm Ø15.9 Ø15.9 Ø15.9 Ø19.05


Piping Connection
Liquid mm Ø9.52 Ø9.52 Ø9.52 Ø9.52

Outline Dimension WxHxD mm 958x412x1349 958x412x1349 958x412x1349 1085x427x1365

Package Dimension WxHxD mm 1043x453x1500 1043x453x1500 1043x453x1500 1143x478x1505

Net Weight/ Gross Weight Outdoor kg 108.0/118.0 105.0/115.0 114.0/124.0 126.0/138.0

Light Commercial Air Conditioners | 9


Specifications for Cassette Type
Model WC36PTCG31UE WC36PTCG33UE WC48PTCG31UE

Function Cooling & Heating Cooling & Heating Cooling & Heating

T1 Cooling Btu/h 29400 34100 41200

Capacity T3 Cooling Btu/h 22800 - 34400

Heating Btu/h 35000 39200 51400

T1 EER/T3 EER/C.O.P (Btu/h)/w, (Btu/h)/w, w/w 11.80/8.30/3.50 2.86/3.42 12.10/8.30/3.40

Power Supply Ph,V,Hz 1Ph,220-240V,50/60Hz 3Ph,380-415V,50Hz 1Ph,220-240V,50/60Hz

Cooling kw 2.49 3.50 3.40


Power input
Heating kw 2.94 3.30 4.44

Cooling A 11.40 8.00 15.50


Current Input
Heating A 13.20 7.50 20.00

Climate Type T3 T3 T3

Indoor Unit

Airflow Volume m3/h 1650 1800 2050

Sound Pressure Level dB(A)(SH/H/M/L) 51/49/46/43 53/52/48/44 55/53/47/41

Outline Dimension mm 840x840x320 122x775x290 910X910X290

Package Dimension mm 963x963x409 1338x877x305 1023X993X375

Net Weight/ Gross Weight kg 31.0/39.0 46.0/53.0 43.0/51.0

Outdoor Unit

Sound Pressure Level Outdoor dB(A) 63 60 63

Brand Brand GREE HITACHI GREE

Type Type Inverter Rotary Inverter


Compressor
LRA A - 49 -

RLA A 19 6.9 21

Refrigerant R410a R410a R410a

Gas mm Ø16.0 Ø16.0 Ø19.00


Piping Connection
Liquid mm Ø9.52 Ø9.52 Ø9.52

Outline Dimension WxHxD mm 1107x440x1100 1107x440x1100 1085x427x1365

Package Dimension WxHxD mm 1158x493x1235 1158x493x1235 1143x478x1505

Net Weight/ Gross Weight Outdoor kg 94.0/102.0 94.0/102.0 120.0/130.0

10 | Light Commercial Air Conditioners


Specifications for Cassette Type
Model WC48RTCG33UE WC60RTCG33UE

Function Cooling & Heating Cooling & Heating

T1 Cooling Btu/h 48100 51200

Capacity T3 Cooling Btu/h - -

Heating Btu/h 51200 57300

T1 EER/T3 EER/C.O.P (Btu/h)/w, (Btu/h)/w, w/w 2.94/3.06 2.83/3.23

Power Supply Ph,V,Hz 3Ph,380-415V,50Hz 3Ph,380-415V,50Hz

Cooling kw 4.80 5.30


Power input
Heating kw 4.90 5.20

Cooling A 9.30 10.50


Current Input
Heating A 9.50 10.30

Climate Type T3 T3

Indoor Unit

Airflow Volume m3/h 1650 1800

Sound Pressure Level dB(A)(SH/H/M/L) 52/47/46/43 53/51/49/47

Outline Dimension mm 840x840x320 840x840x290

Package Dimension mm 963x963x409 963x963x379

Net Weight/ Gross Weight kg 33.0/42.0 37.0/46.0

Outdoor Unit

Sound Pressure Level Outdoor dB(A) 60 61

Brand Brand SANYO SANYO

Type Type Rotary Rotary


Compressor
LRA A 73 73

RLA A 8.7 9.3

Refrigerant R410a R410a

Gas mm Ø19.05 Ø19.05


Piping Connection
Liquid mm Ø12.70 Ø12.70

Outline Dimension WxHxD mm 1120x440x1100 980x410x1350

Package Dimension WxHxD mm 1158x483x1235 1027x443x1500

Net Weight/ Gross Weight Outdoor kg 103.0/115.0 118.0/129.0

Light Commercial Air Conditioners | 11


Indoor Introduction
Duct Type Indoor Unit

The static pressure can be adjusted within 0~150Pa, applicable for various installation requirements.

Adjustable Fan Speed


Fan speed of indoor unit can be adjusted by wired controller and there are three kinds of speeds (high, medium
and low) to meet different requirements.

Highly Flexible Installation


Highly flexible installation is possible to satisfy Flexible and easy to install in L shape, U shape and
various needs. large rooms.

Fresh Air Control (optional) Drain Pump Lift (optional)

12 | Light Commercial Air Conditioners


Specifications for Ducted Type
Model WD36PNCG31UE WD36RNCG31UE WD42PNCG31UE

Function Cooling & Heating Cooling & Heating Cooling & Heating

T1 Cooling Btu/h 34120 34120 39238


Capacity
Heating Btu/h 40944 40944 46062

SEER/S.C.O.P W/W 5.6/4.0 5.1/4.0 5.6/3.8

Power Supply Ph,V,Hz 1Ph,220-240V,50Hz 3Ph,380-415V,50Hz 1Ph,220-240V,50Hz

Cooling kw 3.20 3.12 4.00


Power input
Heating kw 3.40 3.32 3.90

Cooling A 15.00 5.40 18.60


Current Input
Heating A 15.50 5.80 18.10

Climate Type T1 T1 T1

Indoor Unit

Airflow Volume m3/h 2100 2100 2100

Sound Pressure Level dB(A)(SH/H/M/L) 53/52/48/44 53/52/48/44 53/52/48/44

Outline Dimension mm 1226x775x290 1226x775x290 1226x775x290

Package Dimension mm 1338x877x305 1338x877x305 1338x877x305

Net Weight/ Gross Weight kg 46.0/53.0 46.0/53.0 46.0/53.0

Outdoor Unit

Sound Pressure Level Outdoor dB(A) 63 63 63

Brand GREE GREE GREE


Compressor
Type Inverter Inverter Inverter

Refrigerant R410a R410a R410a

Gas mm Ø15.9 Ø15.9 Ø15.9


Piping Connection
Liquid mm Ø9.52 Ø9.52 Ø9.52

Outline Dimension WxHxD mm 1107x440x1100 1107x440x1100 958x412x1349

Package Dimension WxHxD mm 1158x493x1235 1158x493x1235 1043x453x1500

Net Weight/ Gross Weight Outdoor kg 92.0/100.0 98.0/106.0 95.0/105.0

Light Commercial Air Conditioners | 13


Specifications for Ducted Type
Model WD42RNCG31UE WD48PNCG31UE WD48RNCG31UE WD60RNCG31UE

Function Cooling & Heating Cooling & Heating Cooling & Heating Cooling & Heating

T1 Cooling Btu/h 39238 47768 47768 54592


Capacity
Heating Btu/h 46062 52886 52886 56298

SEER/S.C.O.P W/W 5.6/4.0 6.1/3.8 5.6/3.8 5.6/3.8

Power Supply Ph,V,Hz 3Ph,380-415V,50Hz 1Ph,220-240V,50Hz 3Ph,380-415V,50Hz 3Ph,380-415V,50Hz

Cooling kw 4.00 4.70 5.10 5.60


Power input
Heating kw 3.90 4.40 4.50 4.57

Cooling A 6.90 21.80 8.80 9.70


Current Input
Heating A 6.70 20.40 7.80 7.90

Climate Type T1 T1 T1 T1

Indoor Unit

Airflow Volume m3/h 2100 2400 2400 3000

Sound Pressure Level dB(A)(SH/H/M/L) 53/52/48/44 55/53/49/45 55/53/49/45 57/56/54/49

Outline Dimension mm 1226x775x290 1340x750x350 1340x750x350 1340x750x350

Package Dimension mm 1338x877x305 1423x837x455 1423x837x455 1423x837x455

Net Weight/ Gross Weight kg 46.0/53.0 56.0/65.0 56.0/65.0 57.0/69.0

Outdoor Unit

Sound Pressure Level Outdoor dB(A) 61 59 59 63

Brand Brand GREE GREE GREE GREE


Compressor
Type Type Inverter Inverter Inverter Inverter

Refrigerant R410a R410a R410a R410a

Gas mm Ø15.9 Ø15.9 Ø15.9 Ø19.05


Piping Connection
Liquid mm Ø9.52 Ø9.52 Ø9.52 Ø9.52

Outline Dimension WxHxD mm 958x412x1349 958x412x1349 958x412x1349 1085x427x1365

Package Dimension WxHxD mm 1043x453x1500 1043x453x1500 1043x453x1500 1143x478x1505

Net Weight/ Gross Weight Outdoor kg 108.0/118.0 105.0/115.0 114.0/124.0 126.0/138.0

14 | Light Commercial Air Conditioners


Specifications for Ducted Type
Model WD36PTCG31UE WD36RTCG33UE WD48PTCG31UE

Function Cooling & Heating Cooling & Heating Cooling & Heating

T1 Cooling Btu/h 29400 29400 40000

Capacity T3 Cooling Btu/h 26400 26400 37000

Heating Btu/h 35800 35800 50200

T1 EER/T3 EER/C.O.P (Btu/h)/w, (Btu/h)/w, w/w 11.80/8.30/3.50 11.80/8.30/3.50 11.80/8.30/3.50

Power Supply Ph,V,Hz 1Ph,220-240V,50/60Hz 3Ph,380-415V,50Hz 1Ph,220-240V,50/60Hz

Cooling kw 2.49 2.49 3.39


Power input
Heating kw 3.00 3.00 4.20

Cooling A 11.40 11.40 15.50


Current Input
Heating A 13.50 13.50 18.90

Climate Type T3 T3 T3

Indoor Unit

Airflow Volume m3/h 1800 1800 2700

Sound Pressure Level dB(A)(SH/H/M/L) 53/52/48/44 53/52/48/44 57/56/54/49

Outline Dimension mm 1226x775x290 1226x775x290 1340x750x350

Package Dimension mm 1338x877x305 1338x877x305 1423x837x455

Net Weight/ Gross Weight kg 46.0/53.0 46.0/53.0 59.0/70.0

Outdoor Unit

Sound Pressure Level Outdoor dB(A) 63 60 63

Brand Brand GREE HITACHI GREE

Type Type Inverter Rotary Inverter


Compressor
LRA A - 49 -

RLA A 19 6.9 21

Refrigerant R410a R410a R410a

Gas mm Ø16.0 Ø16.0 Ø19.00


Piping Connection
Liquid mm Ø9.52 Ø9.52 Ø9.52

Outline Dimension WxHxD mm 1107x440x1100 1107x440x1100 1085x427x1365

Package Dimension WxHxD mm 1158x493x1235 1158x493x1235 1143x478x1505

Net Weight/ Gross Weight Outdoor kg 94.0/102.0 94.0/102.0 120.0/130.0

Light Commercial Air Conditioners | 15


Specifications for Ducted Type

Model WD48RTCG33UE WD60PTCG31UE WD60RTCG33UE

Function Cooling & Heating Cooling & Heating Cooling & Heating

T1 Cooling Btu/h 48100 50200 54600

Capacity T3 Cooling Btu/h - 45000 -

Heating Btu/h 51900 56200 61400

T1 EER/T3 EER/C.O.P (Btu/h)/w, (Btu/h)/w, w/w 9.63/3.23 12.10/8.60/3.50 9.75/3.27

Power Supply Ph,V,Hz 3Ph,380-415V,50Hz 1Ph,220-240V,50/60Hz 3Ph,380-415V,50Hz

Cooling kw 4.80 4.15 5.30


Power input
Heating kw 4.90 4.71 5.20

Cooling A 9.30 19.00 10.50


Current Input
Heating A 9.50 21.20 10.30

Climate Type T3 T3 T3

Indoor Unit

Airflow Volume m3/h 2300 3200 2500

Sound Pressure Level dB(A)(SH/H/M/L) 53/52/50/50 55/53/52/49 56/52/49/49

Outline Dimension mm 1230x790x290 1497x799x389 1235x830x330

Package Dimension mm 1338x837x305 1578x883x472 1338x885x345

Net Weight/ Gross Weight kg 53.0/60.0 59.0/70.0 56.0/64.0

Outdoor Unit

Sound Pressure Level Outdoor dB(A) 60 63 61

Brand Brand SANYO GREE SANYO

Type Type Rotary Inverter Rotary


Compressor
LRA A 73 - 73

RLA A 8.7 21 9.3

Refrigerant R410a R410a R410a

Gas mm Ø19.05 Ø19.00 Ø19.05


Piping Connection
Liquid mm Ø12.70 Ø9.52 Ø12.70

Outline Dimension WxHxD mm 1120x440x1100 1085x427x1365 980x410x1350

Package Dimension WxHxD mm 1158x483x1235 1143x478x1505 1027x443x1500

Net Weight/ Gross Weight Outdoor kg 103.0/115.0 120.0/130.0 118.0/129.0

16 | Light Commercial Air Conditioners


Duct Split Unit
High Efficiency Series (Side Discharged)*

It is a kind of split system that can be connected with air duct of EER 11.8 to realize cooling.

36K 48/55K

• Energy-saving technology, low operating noise. • Strong Self-protection function.


• Double ambient temperature sensor control. • Flexible and convenient installation.
• Indoor unit independent control.

Item Nominal operating condition (temperature) Operation range (temperature)

Outdoor condition Indoor condition Outdoor condition

DB (°C ) WB (°C) DB (°C ) WB (°C) DB (°C )

T1:35 T1:24 T1:27 T1:19


Cooling 21~52
T3:46 T3:24 T3:29 T3:19

Commercial Air Conditioning | 17


Specifications for Ducted Type
Outdoor Unit WD36PTCG32UCO WD36RTCG32UCO
Model
Indoor Unit WD36PTCG32UCI WD36RTCG32UCI

kW 10.3 12
Capacity Cooling
Btu/h 35144 40944

EER /COP W/W 3.43 3.53

Power supply V/Hz/Ph 220-240V ~ 50Hz 380-415V 3N~ 50Hz

Power input Cooling kW 3.00 3.40

Current input Cooling A 13 8.5

Refrigerant charge volume kg 2.8 2.8

CFM 1235/1058/970/882 1235/1058/970/882


Air flow volume(SH/H/M/L)
m³/h 2100/1800/1650/1500 2100/1800/1650/1500

Rated Pa 37 37
ESP
Range Pa 0~150 0~150
Indoor unit
Sound pressure level(H/M/L) dB(A) 40/39/37 40/39/37

Outline mm 1400×700×300 1400×700×300


Dimension (W×D×H)
Package mm 1601×813×365 1601×813×365

Net weight/Gross weight kg 50/56 50/56

Outline mm 940×460×820 940×460×820


Dimension (W×D×H)
Outdoor unit Package mm 1083x573x973 1083x573x973

Net weight/Gross weight kg 83/93 83/93

Gas inch(mm) Ø3/8(9.52) Ø3/8(9.52)


Connecting pipe Outdoor diameteter
Liquid inch(mm) Ø5/8(15.9) Ø5/8(15.9)
diameter
Max. distance Height/Length m 30/50 30/50

Loading quantity 40'GP/40'HQ set 90/98 90/98

Note: All models of this series are under development. Please confirm the final specifications with sales representatives.

Outdoor Unit WD48RTCG32UCO WD60RTCG32UCO


Model
Indoor Unit WD48RTCG32UCI WD60RTCG32UCI

kW 14 16
Capacity Cooling
Btu/h 47768 54592

EER /COP W/W 3.5 3.56

Power supply V/Hz/Ph 380-415V 3N~ 50Hz 380-415V 3N~ 50Hz

Power input Cooling kW 4.00 4.50

Current input Cooling A 10 11.25

Refrigerant charge volume kg 4.4 4.3

CFM 1471/1294/1176/1059 1413/1154/983/812


Air flow volume(SH/H/M/L)
m³/h 2500/2200/2000/1800 2400/1960/1670/1380

Rated Pa 50 50
ESP
Range Pa 0~200 0~200
Indoor unit
Sound pressure level(H/M/L) dB(A) 41/39/38 41/39/38

Outline mm 1400×700×300 1400×700×300


Dimension (W×D×H)
Package mm 1678x808x365 1601×813×365

Net weight/Gross weight kg 57/64 57/64

Outline mm 980x410x1350 940×320×1430


Dimension (W×D×H)
Package mm 1027x443x1500 1038×438×1580
Outdoor unit
Net weight/Gross weight kg 118/129 118/129

Gas inch(mm) Ø3/8(9.52) Ø3/8(9.52)


Connecting pipe Outdoor diameteter
Liquid inch(mm) Ø3/4(19.05) Ø3/4(19.05)
diameter
Max. distance Height/Length m 30/50 30/50

Loading quantity 40'GP/40'HQ set 43/46 79/86

18 | Commercial Air Conditioning


More Convenient & Comfortable
Multiple Temperature Displays
Indoor set temperature, indoor ambient temperature and outdoor ambient temperature can be displayed. Mean-
while, the display of the three kinds of temperature can be switched freely through the remote controller or wired
controller.

Setting Function of Indoor Dual Temperature Sensors


In order to better control indoor ambient temperature and improve
user’s comfort, we design the indoor dual temperature sensors.
Indoor unit and wired controller are equipped with the temperature
sensors. The unit will automatically start the suitable temperature
sensor according to the mode.

Cold Air Prevention Function Power-off Memory Function


When the unit just starts heating or the outdoor unit The user can set power-off memory function. If this
just finishes defrosting, the temperature of indoor function is activated, the unit will automatically oper-
evaporator is quite low. If the indoor fan operates in ate in previous setting mode when power recovers af-
this case, cold air will come out. Our products are ter power failure.
optimized in design to prevent cold air so as to
improve user’s comfort

Two Thermostats Control One Unit


In order to provide convenient operation to user, we
develop the dual wired controllers control function. In
this case, the user can install the wired controller in
different places for convenient operation.

Commercial Air Conditioning | 19


More Intelligent Control
Remote Controller

Centralized Control Function

The indoor unit is equipped with the interface that can be connected with Westinghouse smart zone controller, in
order to realize central control of 16 units in maximum without connecting wired controller. It can control the on/off,
mode, fan speed, temperature setting and timer of a single unit or a group of units.

20 | Commercial Air Conditioning


Malfunction Relay Output Function

The unit can be connected with the warning apparatus. When a certain unit stops for malfunction, the warning
apparatus will give out warning to remind the administrator for maintenance.

Building Management System Interface (MODBUS Protocol) and Long-distance Monitoring

The unit is with build-in MODBUS interface. If the unit is to be connected with the building management system,
please consult with Westinghouse for the development of MODBUS protocol. In this case, the unit operation infor-
mation will be sent to the building management system in order to control and monitor the unit.

Commercial Air Conditioning | 21


Non-polar Communication Wire

The communication between indoor unit PCB and outdoor unit PCB, and the communication between wired con-
troller and indoor mainboard adopt non-polar communication wire. Normal 2-core power cord or telephone wire
can be used as the communication wire, instead of the shielded twisted pair wire

Gate Control Function (Optional)

This function is especially for some special places like hotels, which is optional. When this function is set and gate
control accessories are connected, the unit will control unit on/off according to the card status detected by the gate
control detection board. When the card is removed, the unit will turn to standby status.

22 | Commercial Air Conditioning


Control System Lineup

Product series
Duct type Cassette type
Control system

WHYB1FA

WHYV1FB7F

WHYV1FB7

Wireless remote controller

WHYB1FAF

WHYAM1F

WHYAMIFF

WHXK60

Wired controller

WHXK75

Note: means standard, means optional.

Commercial Air Conditioning | 23


Rooftop Packaged AC Series
Energy efficient and reliable solutions.
Rooftop Packaged Unit
It is a kind of packaged air conditioner that can be installed either on ground or roof and widely used in villas,
hotels, schools, supermarkets and factories

5RT 8RT 15RT 25RT

• All DC inverter is adopted for high efficiency.

• Dual-compressor control: in low-load condition, only one compressor will operate; compressors can take turns to
operate (applicable to 8~25 ton models).

• Detachable filter, easy for cleaning


.
• Filter cleaning reminding function.

• I-demand function: it is used to control the total power within 75% of the rated power.

• Cooling of drive module adopts refrigerant cooling technology, which is more reliable (applicable to 8RT and
15RT models).

Nominal operating condition (temperature) Operation range (temperature)

Item Outdoor condition Indoor condition Outdoor condition

DB (°C ) WB (°C) DB (°C ) WB (°C) DB (°C )

Cooling 35 24 27 19 5 Ton : -5~52°C : 8~15 Ton : 5~52°C : 25 Ton : 18~52°C

Heating 7 6 20 15 5~8 Ton : -15~24°C : 15 Ton : 5~52°C : 25 Ton : -10~24°C

Commercial Air Conditioning | 24


Specifications
Model WP5STCG32H WP8STCG32H WP15STCG32H WP25STCG32H

Capacity Cooling kW 15.6 (7.00-18.10) 25.80 (9.00-36.00) 40.00 (14.60-52.10) 42.00 (19.90-80.30)

Heating kW 17.4 (4.4~22.0) 25.78 (9.0~34.0) 47.00 (14.6~60.0) 71.5 (20.5~76.2)

EER/COP W/W 11.6 (5/11.90) 11.25/10.85 11.00/11.85 11.10/9.90

Power supply Ph/V/Hz 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60 3/380~415/50/60

Cooling kW 4.55 7.80 12.35 13.00


Power input
Heating kW 5.00 8.10 13.50 24.60

Cooling A 8.20 13.60 20.50 21.00


Current input
Heating A 8.90 14.20 22.50 39.00

Refrigerant charge volume kg 5.00 16.00 21.00 25.00

Dehumidifying volume L/h 2.40 7.60 15.60 25.50

CFM 1677/1560/1354 2702/2472/2236 4943/4473/4002 8530


Airflow volume (H/M/L)
m³/h 2850/2650/2300 4600/4200/3800 8400/7600/6800 14500

Rated Pa 50 70 100 100


ESP
Range Pa 0~110 0~140 0~170 0~220

Sound pressure level dB(A) 63 69 72 72

inch 1.06 1.06 1.06 1.2


Condensation water pipe
mm 27 27 27 30

Outline mm 1750×1100×815 2210×1450×1225 2810x2240x1245 2880×2240×1270


Dimension (W×D×H)
Package mm 1760×1110×850 2220×1460×1250 2825x2255x1285 2893×2253×1290

Net Weight/Gross weight kg 300/320 527/570 920/965 1157/1201

Loading quantity 40’GP/40’HQ set 26/39 8/16 4/8 4/8

Control System Lineup

Product series
Duct type
Control system

Wired remote controller WHZ4K351GJ

WHYB1FA
Wireless remote controller

Centralized controller WHCE52-24/F(C)

Note: means standard, means optional.

25 | Commercial Air Conditioning


Multi W5 VRF Series
Energy efficient and reliable solutions.
Multi W5
Key Features
All DC Inverter Technology to Improve Compression Efficiency

All DC inverter compressor and high-performance high pressure chamber are adopted to reduce loss of overheat
and improve compression efficiency from direct intake. Compared with low pressure chamber, the compression
efficiency is improved. High-efficient permasyn motor is adopted to provide better performance than traditional DC
inverter compressor.

All DC Inverter Compressor

All DC inverter compressor is used in this system. It can directly intake gas to reduce loss of overheat and improve
efficiency

High-efficient permasyn motor is adopted to provide better performance than traditional DC inverter compressor.

26 | VRF
Technology of Maximum Torque Control with Minimum
Current It can reduce energy loss caused by device winding so as to realize higher efficiency.

Low-frequency Torque
Control It can directly control motor torque, through which fan motor can run at a low speed. Users will feel more
comfortable while requirements of the system are also met.

VRF | 27
180° Sine Wave DC Speed Varying Technology
It can satisfy various places’ demands for different temperature and is able to save a great deal of electricity and
provide users with utmost comfort at the same time.

Sensorless DC Inverter Fan Motor


Stepless speed regulation ranges from 5Hz to 65Hz.Compared with traditional inverter motors, the operation is
more energy-saving.

Sensorless control technology


It guarantees lower noise, less vibration and steadier operation.

28 | VRF
Additional Info

88HP Max Capacity-The Largest Free Combination

Max capacity of single outdoor unit reaches 22HP and max combination capacity is even up to 88HP, in an industry
leading level.

Wide Range of Operation Condition

Outdoor operation temperature range is improved to -5°C~52°C in cooling and -20°C~24°C in heating.

Five-way Piping Connection

Piping and wiring are available to the front and back, left and right, and bottom.
The five-way piping connection reduces installation difficulty and cost, improves the installation efficiency.

VRF | 29
Debugging without wired Controller

Debugging can be conducted for the system without the wired controller, thus avoiding any damage to the
controller during the construction process. After completion of the project, the wired controller can be installed.

Easy Installation and Maintenance

Compact Design

With compact design, the outdoor unit can be carried to the roof of the building through the elevator. A crane is not
required and hence facilitates easy delivery and installation.

Company A Multi W5 HR

Easy Transportation

Optimized base frame makes the installation of the outdoor unit convenient and reliable.

30 | VRF
Efficiency

High Efficiency and More Energy Saving

Thanks to the advanced all DC inverter technology, optimized system design and accurate intelligent control
technology, Westinghouse VRF have high EER of up to 4.31 and COP of up to 4.55

WMV5
Multi W5 CP ERF Multi W5 ERF Multi W5 CP COP

New Generation of Energy-saving Operation Control Technology with Energy Saving Up to 20%

The system has 2 modes for energy saving, which can be chosen to meet different electricity demands.

Mode 1: In auto energy-saving mode, the system will self-adjust parameters according to the operation status,
thus to lower the cost of electricity. Up to 15% of energy can be saved.
Mode 2: In compulsory energy-saving mode, the system will limit power output forcibly. Up to 20% of energy can
be saved.

VRF | 31
Intelligent Defrosting Control
During the heating process, the frost status of the unit will be different after affecting by factors of outdoor ambient
temperature, load status and operation time. Through real-time detection of operation parameters of the system, it
can decide the defrosting time by intelligently estimating the thickness of frost, high pressure of system and
blockage status of heat exchanger.

Lower Power Consumption Operation Mode Engineering Debugging for Convenient


Construction
As for the area with power consumption limited
time period, the maximum power consumption can Multi W5 CP has five auto debugging features:
be set for the operation. - Automatic allocation of IDU and ODU addresses
Basing on the power consumption of unit and user’s - Automatic detection of IDU and ODU quantity
requirement, power consumption limitation can be
set according to 100%, 90% or 80% of the capacity - Automatic detection of errors
of complete unit. In this case, user can have more - Automatic start-up of debugging
selection at the power consumption limited time - Real-time judgment of pipe errors
period

32 | VRF
Diversified debugging methods for satisfying different requirements and improving debugging efficiency:

- Button debugging of outdoor unit

- Special Multi W5 debugging system

WHCE41-24/F(C) debugger has functions of debugging of complete unit, independent debugging of indoor unit,
malfunction display, data record and so on. It’s no need to connect special software and PC. Moreover, it can con-
nect external USB storage data.

Specifications
Model WVC224WECG3T2S WVC280WECG3T2S WVC280WE1CG3T2S WVC335WECG3T2S WVC400WECG3T2S

Function Cooling &Heating Cooling & Heating Cooling & Heating Cooling & Heating Cooling & Heating

Cooling Capacity Nom* kW 22.4 28 28 33.5 40

Nom* kW 25 31.5 31.5 37.5 45


Heating Capacity
Max kW 25 31.5 31.5 37.5 45

Nom* Ducted kW/kW 4.73 4.48 3.05 3.99 3.8


EER
Cassette kW/kW 3.27 3.05 2.66 2.8 3.03

Nom* Ducted kW/kW 5.2 5.56 4.1 5.25 4.73

C.O.P Cassette kW/kW 3.54 3.66 3.24 3.64 3.62

Max kW/kW 5.2 5.56 4.1 5.25 4.73

Power Supply Ph/V/H 3Ph,380-415V,50/60Hz 3Ph,380-415V,50/60Hz 3Ph,380-415V,50/60Hz 3Ph,380-415V,50/60Hz 3Ph,380-415V,50/60Hz

Power Consumption Nom* Ducted kW 4.74 6.25 9.18 8.40 10.53


of Cooling Cassette kW 6.85 9.18 10.53 11.96 13.20

Nom* Ducted kW 4.81 5.67 7.68 7.14 9.51


Power Consumption
Cassette kW 7.06 8.61 9.72 10.30 12.43
of Heating
Max. kW 4.81 5.67 7.68 714.00 9.51

Max Circuit/Fuse Current A 16.1/20 20.9/25 20.9/25 24.7/32 28.8/40

Climate Type T3 T3 T3 T3 T3

Maximum Drive IDO NO. Unit 13 16 16 19 23

Refrigerant Charge Volume kg 5.9 9 6.7 8.2 9.8

Sound Pressure Level dB(A) 60 61 61 63 63

Outline Dimension mm 930x765x1605 930x765x1605 930x765x1605 1340x765x1605 1340x765x1605

Package Dimension mm 1010x840x1775 1010x840x1775 1010x840x1775 1420x840x1775 1420x840x1775

Net Weight/ Gross Weight kg 225/235 235/245 225/235 285/300 360/375

Liquid mm 9.52 9.52 9.52 12.7 12.7


Connecting Pipe
Gas mm 19.05 22.2 22.2 25.4 25.4

40’GP set 24 24 24 16 16
Loading Quantity
40’HQ set 24 24 24 16 16

VRF | 33
Specifications
Model WVC450WECG3T2S WVC450WE1CG3T2S WVC504WECG3T2S WVC560WECG3T2S WVC615WECG3T2S

Function Cooling & Heating Cooling & Heating Cooling & Heating Cooling & Heating Cooling & Heating

Cooling Capacity Nom* kW 45 45 50.4 56 61.5

Nom* kW 50 50 50.4 56 61.5


Heating Capacity
Max kW 50 50 56.5 63 69

Nom* Ducted kW/kW 3.51 3.35 3.25 3 2.4


EER
Cassette kW/kW 2.8 2.58 3.4 2.9 2.1

Nom* Ducted kW/kW 4.6 4.2 5.5 4.6 4.5

C.O.P Cassette kW/kW 3.56 3.27 4.2 4 3.8

Max kW/kW 4.6 4.2 4.01 3.8 3.65

Power Supply Ph/V/H 3Ph,380-415V,50/60Hz 3Ph,380-415V,50/60Hz 3Ph,380-415V,50/60Hz 3Ph,380-415V,50/60Hz 3Ph,380-415V,50/60Hz

Power Consumption Nom* Ducted kW 12.82 13.43 15.51 18.67 25.63


of Cooling Cassette kW 16.07 17.44 14.82 19.31 29.29

Nom* Ducted kW 10.87 11.9 9.16 12.17 13.67


Power Consumption
Cassette kW 14.04 15.29 12 14 16.18
of Heating
Max. kW 10.86 11.9 14.1 16.6 18.9

Max Circuit/Fuse Current A 33.2/40 33.2/40 45.4/50 51.1/60 59.2/60

Climate Type T3 T3 T3 T3 T3

Maximum Drive IDO NO. Unit 26 26 29 33 36

Refrigerant Charge Volume kg 10.3 10.3 11.3 14.3 14.3

Sound Pressure Level dB(A) 63 63 63 63 64

Outline Dimension mm 1340x765x1740 1340x765x1605 1340x765x1740 1340x765x1740 1340x765x1740

Package Dimension mm 1420x840x1910 1420x840x1775 1420x840x1910 1420x840x1910 1420x840x1910

Net Weight/ Gross Weight kg 360/375 360/375 360/375 385/400 385/400

Liquid mm 12.7 12.7 15.9 15.9 15.9


Connecting Pipe
Gas mm 28.6 28.6 28.6 28.6 28.6

40’GP set 16 16 16 16 16
Loading Quantity
40’HQ set 16 16 16 16 16

Control System Lineup

Product series
Duct type
Control system

Wired remote controller WHZ4K351GJ

WHYB1FA
Wireless remote controller

Centralized controller WHCE52-24/F(C)

34 | VRF
Multi W5 Solar Series
Energy efficient and reliable solutions.
System Advantages
Zero Electricity Charge - Photovoltaic Direct-driven Technology
Westinghouse team has been working on the research and reformation of air conditioning technology. Westinghose
Photovoltaic Directdriven Inverter Multi VRF System breaks through tradition, combining photovoltaic power gener-
ation with power consumption of air conditioner for the first time. *Condition of zero electricity charge: photovoltaic
generated power ≥ air conditioner consumption demand. Zero electricity charge means when the power generaed
by solar power photovoltaic battery sub-assy completely meets the load of unit in operation, grid power is not
needed, so there is no electricity charge.

1. Seamless Integration of PV Power and Air Conditioner, with Power Generation Function

By adopting advanced photovoltaic direct-driven technology, the


system can achieve power generation by utilizing solar power while
consuming electricity and ensure utilization of photovoltaic power
in priority; compared with traditional photovoltaic system, energy
wastage during multiple commutation of alternating current and
direct current is eliminated, with energy efficiency improved by
6%-8% and photovoltaic utilization ratio up to 99%; besides, the
innovative MPPT(Maximum Power Point Tracking) technology can
track and control the maximum power point status of photovoltaic
power generation, so as to achieve maximum utilization of
photovoltaic power.

2. High Utilization Ratio

In summer, power consumption of air conditioner


is large and photovoltaic power generation is
relatively large as well. Westinghouse
Photovoltaic Directdriven Inverter Multi VRF
System, combining the characteristics of
photovoltaic power, makes sure that the
consumed electricity of units matches with the
photovoltaic power generation so as to achieve
zero electricity charge.

3. Zero Power Consumption from Grid

In rated engineering proportion, the power


amount that Photovoltaic Direct-driven Inverter
Multi VRF System gets from the grid is balanced
with the power amount that the system delivers
to the grid in each day, each month, each quarter
and each year. Generally, power consumed from
the grid is zero.

35 | Photovoltaic VRF
Zero Wastage - Ternary Converting Technology

Westinghouse Photovoltaic Direct-driven Inverter Multi VRF System can not only achieve zero electricity charge, but
also generate power to the grid, benefiting energy conservation and emission reduction.

1. Instant Switchover for Punctual Power Generation


Ternary converting model, consisting of
photovoltaic sub-assy, multi VRF system and
grid, enables two-way flow and multiple-way
integration of power at the direct current
side. The switchover time among five
operation modes is less than 10ms, avoiding
power wastage due to switchover delay.

2. No Wastage of Residual Power

If there is residual power after meeting air conditioner consumption demand, the system can deliver the residual
power to the grid in real time, so as to realize complete utilization of photovoltaic power.

Photovoltaic VRF | 36
Green Inverter Technology
After many years of development and tests, Westinghouse Photovoltaic Direct-driven Inverter Multi VRF System is
capable of providing more reliable and more assured refrigeration service for its technological innovation.

1. No Interference from Other Electric Appliances in the Room

By adopting advanced photovoltaic direct-driven technology, the system can achieve power generation by utilizing
solar power wh ile consuming electricity and ensure utilization of photovoltaic power in priority; compared with
traditional photovoltaic system, energy wastage during multiple commutation of alternating current and direct
current is eliminated, with energy efficiency improved by 6%-8% and photovoltaic utilization ratio up to 99%;
besides, the innovative MPPT(Maximum Power Point Tracking) technology can track and control the maximum
power point status of photovoltaic power generation, so as to achieve maximum utilization of photovoltaic power.

37 | Photovoltaic VRF
2. Easy Maintenance

Westinghouse Photovoltaic Direct-driven Inverter Multi VRF System adopts low-voltage DC component instead of
traditional high-voltage AC component, which effectively ensures safety and greatly reduces hazards of electric
shock during operation and maintenance. Application of low-voltage DC component and DC loop topology greatly
lowers arcing and fire hazards caused by circuit aging and improves EMC performance.

3. Easy Installation

The system applies low-voltage power distribution circuit and cancels neutral wire, which eliminate the impact of
phase sequence and prevent wrong phase sequence connection and virtual connection of neutral, etc. Meanwhile,
engineering adaptability of unit is extended and engineering installation cost is reduced.

4. Long Lifespan

Film capacitor has many advantages, such as high voltage resistance, no polarity, high impulse voltage endurance,
etc. The system adopts film capacitor instead of electrolytic capacitor for longer lifespan.

Photovoltaic VRF | 38
Three Components
Advanced Photovoltaic Direct-driven Inverter Multi VRF System consists of photovoltaic power generation system,
photovoltaic direct-driven Inverter multi VRF and intelligent management system. This system is with high density of
integration, which is widely applicable for houses, office buildings, factories, hospitals, etc. Meanwhile, the building
that is already equipped photovoltaic system and air conditioner can be integrated and reconstructed.

Zero Worry - Green Inverter Technology


Photovoltaic power generation system is the power generation element in Photovoltaic Direct-driven Inverter Multi
VRF System. The clean energy provided by this power generation system will supply power to the main unit and
deliver residual power to the grid through converter.

Photovoltaic power generation system is closely related to the installation site and user’s building. Westinghouse
can design the most suitable photovoltaic power generation system for you according to local climate, user’s build-
ing structure, cooling capacity demand and your special requirements.

Photovoltaic Direct-driven Inverter Multi VRF


1. Energy Saving in Priority. Greatly Reduce Electricity Charge1
The multi VRF system in photovoltaic multi VRF system inherits the essence of multi VRF development in Westing-
house for more than a decade. The system integrates the advanced 180o sine wave high-efficiency compressor
driver technology, 1Hz PID capacity regulation technology, intelligent defrosting, precise refrigerant allocation
technology, high-efficiency heating technology, quiet control technology and intelligent operation technology, etc.
The system can be widely applied in various commercial places for providing energy-saving and comfortable air
conditioning environment to global users.

39 | Photovoltaic VRF
1. Asymmetrical Vortex Line 4. 180° Sine Wave DC Inverter Driver
Asymmetrical vortex line is adopted to reduce Stepless sine wave output by inverter drives
leakage loss and invalid suction overheating. DC inverter to achieve highefficiency stepless
DC frequency conversion, which improves
motor efficiency.

2. Non-Contact Oil Seal


Axial direction and radial direction of 5. Positive-DC Displacement Gear Oil Pump
compression cavity adopts non-contact oil Positive-displacement gear oil pump ensures
seal to reduce attrition and improve efficiency necessary oil supply in high & low frequency
and reliability. and high reliability of compressor.

3. Permanent Magnet Synchronous DC Motor


Rare earth is adopted in the rotor and the
shape is optimized, so as to achieve wide
frequency, high efficiency and low noise.

Photovoltaic VRF | 40
2. Quiet Control for Building High-Quality Life

Westinghouse Photovoltaic Direct-driven Inverter Multi VRF System sufficiently considers people’s demand for com-
fort, upgrading comfort with user-friendly technology. The system is capable of wider operation range and lower
operation noise.

• Optimized River Diversion Shell Design


After tens of thousands times of CFD simulation, new fan
river diversion shell structure is developed to reduce
vibration of river diversion ring in high-speed operation
of fan. Compared with conventional design, noise value
can be reduced by 3dB(A).

• High-Efficiency 3D Axial Blade


The new high-efficiency axial blade is designed with
optimized blade outline and better edge curve.
Compared with conventional blade, it can increase air
volume by 12%, improving efficiency as well as lowering
noise.
High-efficiency Blade

3. Excellent Performance Ensured by Advanced Technology

Westinghouse Photovoltaic Direct-driven Inverter Multi VRF System provides reliable performance through several
mature technologies such as two-stage oil separation control technology, oil return control technology, oil balance
control technology and sub-cooling control technology.
• Pressure Sensor Detection Control Technology • Temperature Sensor Detection Control
Pressure sensor can precisely detect system high Various temperature sensors are equipped to
pressure and low pressure, and adjust output detect ambient temperature, indoor
of fan and compressor, so as to make sure the temperature and refrigerant’s evaporating
system can work under the most energy-saving temperature, from which the operation status
pressure condition. can be measured to ensure stable operation.

41 | Photovoltaic VRF
Intelligent Management System

The centralized controller for power generation and consumption


management is the brain of Photovoltaic Direct-driven Inverter
Multi VRF System. It adopts the perfect combination of multi VRF
intelligent network system and power generation and consumption
management system based on CAN communication technology, so
as to achieve intelligent management of multi VRF system.

WHCE55-24 F(C) (optional)

• Centralized Controller for Power Generation and Consumption Management: One Screen for Convenient Operation
Centralized controller for power generation and consumption management combines photovoltaic power generation,
unit power consumption and grid power supply for power management with centralized control of unit, achieving
intelligent management of multi VRF system.
Photovoltaic parameter inquiry and real-time display of power generation and consumption data are available. You can
see photovoltaic power generation, unit power consumption, monthly electricity consumption and yearly electricity
consumption. Power curve of the system is shown in real time and updated dynamically.

• Reliable Multi VRF Intelligent Network System Based on CAN Bus Technology
The multi VRF intelligent network system adopts Westinghouse patented multi VRF CAN non-polar bus communication
technology, which features high stability, convenient networking and high communication efficiency.

• Intelligent Management of Air Conditioning System for Centralized Management and Convenience
Centralized controller for power generation and consumption management provides intelligent control management of
the air conditioner of photovoltaic Multi VRF system, with complete functions and convenient operation.

Photovoltaic VRF | 42
Five Working Modes
The system can realize real-time switchover for five working modes according to the actual status of photovoltaic
power generation system and operation of multi VRF system.

1. Air Conditioning Mode


When photovoltaic power generation system doesn’t work, the system is powered by commercial power. In this
case, the system equals to an inverter VRF system.

2. Photovoltaic Power Generation Mode


When the air conditioner stops operation, the power generated by the photovoltaic power generation system is
sent to the grid. In this case, the system equals to a power station.

3. Photovoltaic Air Conditioning Mode


When photovoltaic generated power is equal to the air conditioner consumption demand, the air conditioner
consumes photovoltaic power only.

43 | Photovoltaic VRF
4. Photovoltaic Air Conditioning & Power Generation Mode

When photovoltaic generated power is more than air conditioner consumption demand, photovoltaic power will
give priority to the air conditioner, and then the residual power will be sent to the grid.

5. Photovoltaic Air Conditioning & Power Consumption Mode

When photovoltaic generated power is less than the air conditioner consumption demand, air conditioner will draw
power from the grid in addition to the photovoltaic power generation system.

Westinghouse Photovoltaic Direct-driven Inverter Multi VRF System can realize real-time switchover for five working
modes according to the actual status of photovoltaic power generation system and operation of multi VRF system
for ensuring high-efficiency utilization of photovoltaic power and reliable operation

Photovoltaic VRF | 44
Multi W5 Solar
Westinghouse Multi W5 Solar adopts inverter compressor technology, with capacity range from 8HP to 12HP. It has a
broad product lineup and is widely applicable to places such as residential houses, apartments and office buildings.

• With LAN reverse power control technology; efficiency of PV power generation/consumption is more than 99%.
• Active grid configuration, automatically indentifying 208V/230V/380V/415V and 50Hz/60Hz and other global power
supply type.
• Adopt innovative multi-level topology; grid harmonic is as low as 2%.
• Adopt high-efficiency DC inverter compressor for realizing broadband operation, high efficiency and low noise.
• Adopt all new aluminum plastic design, with stronger heat dissipation capability and longer service life (components).
• Adopt modular design concept for the unit’s structure to realize fast-assembly as well as fast-disassembly for all parts.
• The build-in smart energy control module can freely connects to Westinghouse self-developed Information Energy
Management System (IEMS) for smart energy distribution.
• Can connect with Westinghouse Power power storage unit for power supply at night.

Note:This electric cabinet must be with bidirectional rectification function.

45 | Photovoltaic VRF
Specifications

Model WPVC224WCCG3T2O WPVC280WCCG3T2O WPVC335WCCG3T2O

Capacity range HP 8 10 12

Cooling kW 22.40 28.00 33.50


Capacity
Heating kW 25.00 31.50 37.50

Cooling power input kW 5.7 7.0 8.41

Heating power input kW 5.5 7.3 9.0

EER/COP kW/kW 3.93/4.24 4.00/4.32 3.98/4.17

Air flow volume m3/h 11400 11400 14000

Power supply V/Ph/Hz 380-415V-3Ph~50/60Hz

Range of allowable open circuit input voltage V 1000 1000 1000

Range of input operating voltage V 560~780 560~780 560~780

Max. solar short circuit current A 39 39 39

Recommended quantity of solar panel / 22/44/66/88 22/44/66/88 22/44/66/88

Maximum drive IDU NO. unit 13 16 19

Refrigerant charge volume kg 5.9 6.7 11.3

Sound pressure level dB(A) 60 61 63

Liquid inch(mm) Ø3/8(9.52) Ø3/8(9.52) Ø3/8(12.7)


Connecting pipe
Gas inch(mm) Ø3/4(19.05) Ø7/8(22.2) Ø1(25.4)

Outline mm 930×765×1605 930×765×1605 1340×765×1605


Dimension (WxDxH)
Package mm 1010×840×1775 1010×840×1775 1420×840×1775

Net weight/Gross weight kg 266/278 266/278 340/355

40’ GP set 24 24 16
Loading quantity
40’ HQ set 24 24 16

Photovoltaic VRF | 46
Multi W5 Solar Mini Series
Energy efficient and reliable solutions.
Multi W5 Solar Mini
Westinghouse Multi W5 Solar Mini adopts inverter compressor technology, with capacity range from 4HP to 6HP.
It has a broad product lineup and is widely applicable to places such as residential houses, apartments and office
buildings.

4/5/6 HP WHXK46 WHYAP1F

• PV and air conditioner are combined perfectly, air conditioner also has the power generation function.
• The characteristics of power consumption of air conditioner is well matched with that of PV power generation,
with high power generation/consumption ratio.
• Instant switch-over between power generation and power consumption.
• Real-time grid-connected, no waste of electricity.
• Green inverter, no interference to other indoor electric appliances.
• Low voltage and direct current for electric parts, safe for maintenance.
• High efficiency and energy-saving, cutting the electric bill greatly.

Note:This electric cabinet must be with bidirectional rectification function.

Photovoltaic VRF | 47
Specifications

Model WPVR120UACG3S2O WPVR140UACG3S2O WPVR160UACG3S2O

Capacity range HP 4 5 6

Cooling kW 12.30 13.95 15.75


Capacity
Heating kW 13.95 16.50 18.00

Cooling power input kW 3.0 3.8 4.6

Heating power input kW 3.3 4.0 4.7

EER/COP kW/kW 4.10/4.23 3.67/4.12 3.42/3.83

Air flow volume m3/h 6000 6300 6600

Power supply V/Ph/Hz 220-240/208-230/1/50/60

Range of allowable open circuit input voltage V 392~490 392~490 392~490

Bus operating voltage V 314~420 314~420 314~420

Max. solar short circuit current A 27 27 27

Recommended quantity of solar panel / 12 12 12

Maximum drive IDU NO. unit 7 8 9

Refrigerant charge volume kg 3.3 3.3 3.3

Sound pressure level dB(A) 59 60 60

Liquid inch(mm) Ø3/8(9.52) Ø3/8(9.52) Ø3/8(9.52)


Connecting pipe
Gas inch(mm) Ø5/8(15.9) Ø5/8(15.9) Ø3/4(19.05)

Outline mm 900×340×1345 900×340×1345 900×340×1345


Dimension (WxDxH)
Package mm 998×458×1500 998×458×1500 998×458×1500

Net weight/Gross weight kg 121.5/134.5 121.5/134.5 121.5/134.5

40’ GP set 57 57 57
Loading quantity
40’ HQ set 57 57 57

48 | Photovoltaic VRF
Indoor Units Lineup
Specifications of Indoor Units
Type of Indoor
Specification 22 25 28 32 36 40 45 50 56 63 71 72 80 90 100 112 125 140 160 224 280 450
Unit

High Static
Pressure Duct 0 0 0 0 0 0 0 0 0 0 0 0
Type Unit

Low Static
Pressure Duct 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Type Unit

Slim Ducted
Type Indoor 0 0 0 0 0 0 0 0 0 0 0
Unit

4-way Cassette
0 0 0 0 0 0 0 0 0 0 0 0 0 0
Unit

Compact 4-way
Cassette Indoor 0 0 0 0 0 0
Unit

2-way Cassette
0 0 0 0 0 0 0
Indoor Unit

1-way Cassette
0 0 0 0 0
Unit

Wall-mounted
0 0 0 0 0 0 0 0
Type Unit

Floor Ceiling
Type Indoor 0 0 0 0 0 0 0 0 0
Unit

Console Indoor
0 0 0 0 0
Unit

Floor Standing
Type Indoor 0 0
Unit

Fresh Air Pro-


cessing Indoor 0 0 0 0
Unit

VRF Indoor Unit | 49


1. Product Characteristic
1.1 Low static pressure Duct Type Indoor Unit

Features Characteristic
• Low static pressure, low noise.
Especially suitable for rooms of compact structure or samll installation space.
Also it provides you with a comfortable and quiet living environment.
• Convenient installation.
Tab type plastic filter, detachable fan motor, indepen dent water pump
assembly, all for covenient maintenance.
• Intelligent drainage device.
Water heigh difference up to 3.3ft. which can effectively drain out condending
water ande save space.

• Protection function.
Water overflow protection, anti-freezing protection, fan motor overload
protection, temperature sensor malfunction protection.

1.2 Four-way Cassette Type Indoor Unit

Features Characteristic
• Strong and balanced airflow.
Unit features auto operation, Four-way airflow, 7 fan speeds and strong
circulating airflow.
• DC inverter motor.
With good speed regulation performance, motor efficiency improved by
30% vs. normal motor.
• Ultra-low noise operation.
DC inverter motor can realize stepless speed regulation to
lower noise. Indoor unit can be set to work under auto quiet mode via
wired controller.
• Protection function.
Water overflow protection, anti-freezing protection, temperature
sensor malfunction protection, fan motor overload protection.
• Intelligent drainage device.
Water height difference up to 3.3ft. which can effectively drain out
condensing water and save space.

1.3 One-way Cassette Type Indoor Unit

Features Characteristic
• Small installation space.
With 185mm ultrathin design, unit can be installed in the ceiling of 19m deep.
• Detachcble grille and long life filter.
Grille is detachable for easy cleaning. With long life filter, cleaning cycle is
20 times longer.

• High drain pump lift.


Drain pump lift reachws 1.0m, which can effectively drain water.
• Protection function.
Water overflow protection, anti-freezing protection, fan motor overload
protection, temperature sensor malfunction protection, auxiliary
electric heating overheat protection(This function is not included in pure heat
pump unit).

50 | VRF Indoor Unit


Specifications

2.1 Low ESP Duct Type


Model WVDL22GDSCCUO WVDL25GDSCCUO WVDL28GDSCCUO WVDL32GDSCCUO WVDL36GDSCCUO WVDL40GDSC-
CUO

Cooling capacity kW 2.2 2.5 2.8 3.2 3.6 4.0

Heating capacity kW 2.5 2.8 3.2 3.6 4.0 4.5

Air volume m3/h 450 450 450 550 550 750

Unit external static pressure Pa 15/0~30 15/0~30 15/0~30 15/0~30 15/0~30 15/0~30

Cooling power input W 28 28 28 37 37 40

Cooling current input A 0.2 0.2 0.2 0.3 0.3 0.3

Heating power input W 25 25 25 30 30 35

Heating current input A 0.2 0.2 0.2 0.3 0.3 0.3

*Minimum line current A 0.4 0.4 0.4 0.4 0.4 0.4

*Maximum fuse current A 6 6 6 6 6 6

Sound pressure level dB(A) 30 30 30 31 31 33

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35


Piping interface
Gas pipe mm Ø9.52 Ø9.52 Ø9.52 Ø12.7 Ø12.7 Ø12.7

External
Drain pipe mm Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5
diameter × thickness

Dimensions W×D×H mm 710×462×200 710×462×200 710×462×200 710×462×200 710×462×200 1010×462×200

Net weight Main body kg 18.5 18.5 18.5 19 19 25

Model WVDL45GDSCCUO WVDL50GDSCCUO WVDL56GDSCCUO WVDL63GDSCCUO WVDL71GDSCCUO

Cooling capacity kW 4.5 5.0 5.6 6.3 7.1

Heating capacity kW 5.0 5.6 6.3 7.1 8.0

Air volume m3/h 750 850 850 850 1100

Unit external static pressure Pa 15/0~30 15/0~30 15/0~30 15/0~30 15/0~30

Cooling power input W 40 55 55 55 55

Cooling current input A 0.3 0.4 0.4 0.4 0.5

Heating power input W 35 45 45 45 50

Heating current input A 0.3 0.4 0.4 0.4 0.5

*Minimum line current A 0.4 0.6 0.6 0.6 0.8

*Maximum fuse current A 6 6 6 6 6

Sound pressure level dB(A) 33 35 35 35 37

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø6.35 Ø6.35 Ø9.52 Ø9.52 Ø9.52


Piping interface
Gas pipe mm Ø12.7 Ø12.7 Ø15.9 Ø15.9 Ø15.9

External
Drain pipe mm Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5
diameter × thickness

Dimensions W×D×H mm 1010×462×200 1010×462×200 1010×462×200 1010×462×200 1010×462×200

Net weight Main body kg 25 25 25 25 31

VRF Indoor Unit | 51


Model WVDL80GDSCCUO WVDL90GDSCCUO WVDL100GDSCCUO WVDL112GDSC- WVDL125GDSC- WVDL140GDSC-
CUO CUO CUO

Cooling capacity kW 8.0 9.0 10.0 11.2 12.5 14.0

Heating capacity kW 9.0 10.0 11.2 12.5 14.0 16.0

Air volume m3/h 1250 1500 1500 1700 2000 2000

Unit external static pressure Pa 50/0~80 50/0~80 50/0~80 50/0~80 50/0~80 50/0~80

Cooling power input W 110 130 130 130 170 170

Cooling current input A 0.53 0.63 0.63 0.63 0.8 0.8

Heating power input W 110 130 130 130 170 170

Heating current input A 0.53 0.63 0.63 0.63 0.8 0.8

Minimum line current A 0.5 1.0 1.0 1.0 1.0 1.0

Maximum fuse current A 0.8 1.9 1.9 1.9 1.9 1.9

Sound pressure level dB(A) 37 40 40 40 42 42

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52


Pipe diameter
Gas pipe mm Ø15.9 Ø15.9 Ø15.9 Ø15.9 Ø15.9 Ø15.9

External
Drain pipe mm Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5
diameter × thickness

Dimensions W×D×H mm 1200×655×260 1340×655×260 1340×655×260 1340×655×260 1340×655×260 1340×655×260

Net weight kg 39 45.5 45.5 45.5 46.5 46.5

Notes:
1. Rated Cooling capacity test conditions: indoor 27°C DB/19°C WB, outdoor 35°C DB; connection pipe length: 5 m, without height drop
between units
2. Rated heating capacity test conditions: indoor 20°C DB, outdoor 7°C DB/6 °C WB; connection pipe length: 5 m, without height drop between
units
3. In the column of “Unit external static pressure”: The figure before “/” indicates the default external static pressure of unit before delivery, and
the figures after indicate the adjustable static pressure range of unit.

2.2 Four-way Cassette Type

Model WVC28GDCAUO WVC36GDCAUO WVC45GDCAUO WVC50GDCAUO

Cooling capacity kW 2.8 3.6 4.5 5.0

Heating capacity kW 3.2 4.0 5.0 5.6

Air volume m3/h 750 750 750 830

Cooling power input W 48 48 48 50

Cooling current input A 0.2 0.2 0.2 0.2

Heating power input W 48 48 48 50

Heating current input A 0.2 0.2 0.2 0.2

Minimum line current A 0.25 0.25 0.25 0.25

Maximum fuse current A 6 6 6 6

Sound pressure level dB(A) 36 36 36 36

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø6.35 Ø6.35 Ø6.35 Ø6.35


Piping interface
Gas pipe mm Ø9.52 Ø12.7 Ø12.7 Ø12.7

External
Drain pipe mm Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5
diameter × thickness

Main body Dimensions W×D×H mm 840×840×190 840×840×190 840×840×190 840×840×190

Panel Dimensions W×D×H mm 950×950×65 950×950×65 950×950×65 950×950×65

Main body mm 22.5 22.5 22.5 22.5


Net weight
Panel mm 7 7 7 7

52 | VRF Indoor Unit


Model WVC56GDCAUO WVC63GDCAUO WVC71GDCAUO

Cooling capacity kW 5.6 6.3 7.1

Heating capacity kW 6.3 7.1 8.0

Air volume m3/h 1000 1000 1180

Cooling power input W 59 59 68

Cooling current input A 0.3 0.3 0.3

Sound pressure level dB(A) 59 59 68

Sound pressure level dB(A) 0.3 0.3 0.3

Sound pressure level dB(A) 0.38 0.38 0.38

Sound pressure level dB(A) 6 6 6

Sound pressure level dB(A) 37 37 38

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø9.52 Ø9.52 Ø9.52


Piping interface
Gas pipe mm Ø15.9 Ø15.9 Ø15.9

External
Drain pipe mm Ø25×2.5 Ø25×2.5 Ø25×2.5
diameter × thicknes

Main body dimensions W×D×H mm 840×840×240 840×840×240 840×840×240

Panel dimensions W×D×H mm 950×950×65 950×950×65 950×950×65

Main body kg 26.5 26.5 26.5


Net weight
Panel kg 7 7 7

Model WVC80GDCAUO WVC90GDCAUO WVC100GDCAUO WVC112GDCAUO

Cooling capacity kW 8.0 9.0 10.0 11.2

Heating capacity kW 9.0 10.0 11.2 12.5

Air volume m3/h 1180 1500 1500 1700

Cooling power input W 68 98 98 110

Cooling current input A 0.3 0.4 0.4 0.5

Heating power input W 68 98 98 110

Heating current input A 0.3 0.4 0.4 0.5

Minimum line current A 0.38 0.5 0.5 0.63

Maximum fuse current A 6 6 6 6

Sound pressure level dB(A) 38 40 40 41

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø9.52 Ø9.52 Ø9.52 Ø9.52


Piping interface
Gas pipe mm Ø15.9 Ø15.9 Ø15.9 Ø15.9

External
Drain pipe mm Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5
diameter × thickness

Main body dimensions W×D×H mm 840×840×240 840×840×320 840×840×320 840×840×320

Panel dimensions W×D×H mm 950×950×65 950×950×65 950×950×65 950×950×65

Main body kg 26.5 32.5 32.5 32.5


Net weight
Panel kg 7 7 7 7

VRF Indoor Unit | 53


Model WVC125GDCAUO WVC140GDCAUO WVC160GDCAUO

Cooling capacity kW 12.5 14.0 16.0

Heating capacity kW 14.0 16.0 17.5

Air volume m3/h 1860 1860 2100

Cooling power input W 110 110 120

Cooling current input A 0.5 0.5 0.6

Heating power input W 110 110 120

Heating current input A 0.5 0.5 0.6

Minimum line current A 0.63 0.63 0.75

Maximum fuse current A 6 6 6

Sound pressure level dB(A) 43 43 47

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø9.52 Ø9.52 Ø9.52


Piping interface
Gas pipe mm Ø15.9 Ø15.9 Ø19.05

External
Drain pipe mm Ø25×2.5 Ø25×2.5 Ø25×2.5
diameter × thickness

Main body dimensions W×D×H mm 840×840×320 840×840×320 910×910×293

Panel dimensions W×D×H mm 950×950×65 950×950×65 1040×1040×65

Main body kg 32.5 32.5 46.5


Net weight
Panel kg 7 7 7.5

Notes:
1. Rated cooling capacity test conditions: indoor 27°C DB/19°C WB, outdoor 35°C DB; connection pipe length: 5 m, without height drop
between units.
2. Rated heating capacity test conditions: indoor 20°C DB, outdoor 7°C DB/6°C WB; connection pipe length: 5 m, without height drop between
units.

2.3 One-way Cassette Type


Model WVC22GDCAUO WVC28GDCAUO WVC36GDCAUO WVC45GDCAUO WVC50GDCAUO WVC56GDCAUO

Cooling capacity kW 2.2 2.8 3.6 4.5 5.0 5.6

Heating capacity kW 2.5 3.2 4.0 5.0 5.6 6.3

Air volume m3/h 600 600 600 830 830 890

Cooling power input W 30 30 30 45 45 45

Cooling current input A 0.2 0.2 0.2 0.3 0.3 0.3

Heating power input W 30 30 30 45 45 45

Heating current input A 0.2 0.2 0.2 0.3 0.3 0.3

Minimum line current A 0.25 0.25 0.25 0.38 0.38 0.38

Maximum fuse current A 6 6 6 6 6 6

Sound pressure level dB(A) 36 36 36 40 40 41

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø9.52


Piping interface
Gas pipe mm Ø9.52 Ø9.52 Ø12.7 Ø12.7 Ø12.7 Ø15.9

External diameter
Drain pipe mm Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5
× thickness

Main body dimensions W×D×H mm 987×385×178 987×385×178 987×385×178 987×385×178 987×385×178 987×385×178

Panel dimensions W×D×H mm 1200×460×55 1200×460×55 1200×460×55 1200×460×55 1200×460×55 1200×460×55

Main body kg 20 20 20 21 21 21
Net weight
Panel kg 4.2 4.2 4.2 4.2 4.2 4.2

Notes:
1. Rated cooling capacity test conditions: indoor 27°C DB/19°C WB, outdoor 35°C DB; connection pipe length: 5 m, without height drop
between units.
2. Rated heating capacity test conditions: indoor 20°C DB, outdoor 7°C DB/6°C WB; connection pipe length: 5 m, without height drop between
units.

54 | VRF Indoor Unit


1.4 Floor Ceiling Type Indoor Unit

Features Characteristic
• Hoisted or seated, flexible installation
Unit can be hoisted or seated. When seated, suspended ceiling is not
needed.
• Protection function
Anti-freezing protection, temperature sensor malfunction protection, fan
motor overload protection.
• Beautiful appearance
With beautiful and elegant front panel, it is congenial to the indoor
surroundings.
• Horizontal and vertical air swing
Wider air swing range for your comfortable working and living environment.

1.5 Slim Duct Type Indoor Unit

Features Characteristic
• Highly Efficient & Energy-saving.
High-efficiency DC brushless motor is used.Its efficency is improved by
over 30% compared with common motor. Evaporator flow path adosimulating
optimized design via the refrigeration system simulation software, which
hasgreatly increased the heat exchange capacity of evaporator.

• Slim & Small.


The unit is only 200mm’s thick and 450 mm’s deep.Suspended ceiling
doesn’t have to be very high.It is suitable for ordinary rooms.

• Wiring of Electric Control Box.


Mounting board of electeic control box elements are arranged at both sides
of the mounting board of fan motor.There is a wire- cross notch on each side
so that wiring at both sides of the mounting board of fan motor is
convenient and efficient. Strong and week current are also separated to
ensure the effectiveness of week current signtransmission.

• Protection Functions.
Anti-freezing protection,fan motor built-in overload protiection,
temperature sensor protection.

• Ultra-quiet.
High-efficiency centrifugal fan and ultralow noise volute are developed with
ANSYS and Fluent. They have also gained natonal patents. Mean while,inlet
mute valve is adopted so that noise of the complete unit is greatly reduced.

• Fast & Strong.


Intlligent temperature control technology is adopted.Cooling/Heating
function is fast and strong so that room temperature can quickly reach set
temperature.
• Flexible Insrallation.
Based on the requirements of building and utilization,different ways of air
return and different air supply static pressure can be selected.
• CAN Bus Communication Technology.
System response speed is faster and communication is more reliable. Auto
addressing, non-polar communication,free wire matching.
• Convenient Operation & Maintenance.
Electric control box is attached independently so that it can be detached as
a whole,which is convenient for fan and motor is also convenient.

VRF Indoor Unit | 55


2.4 Floor Ceiling Type
Model WVF28GDCAUO WVF36GDCAUO WVF50GDCAUO WVF56GDCAUO WVF63GDCAUO WVF71GDCAUO

Cooling capacity kW 2.8 3.6 5.0 5.6 6.3 7.1

Heating capacity kW 3.2 4.0 5.6 6.3 7.1 8.0

Air volume m3/h 650 650 950 950 1400 1400

Cooling power input W 40 40 50 50 75 75

Cooling current input A 0.3 0.3 0.4 0.4 0.6 0.6

Heating power input W 40 40 50 50 75 75

Heating current input A 0.3 0.3 0.4 0.4 0.6 0.6

Minimum line current A 0.32 0.32 0.43 0.43 0.64 0.64

Maximum fuse current A 6 6 6 6 6 6

Sound pressure level dB(A) 36 36 42 42 44 44

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø6.35 Ø6.35 Ø6.35 Ø9.52 Ø9.52 Ø9.52


Piping interface
Gas pipe mm Ø9.52 Ø12.7 Ø12.7 Ø15.9 Ø15.9 Ø15.9

External
Drain pipe mm Ø17×1.75 Ø17×1.75 Ø17×1.75 Ø17×1.75 Ø17×1.75 Ø17×1.75
diameter × thickness

Outline Dimensions W×D×H mm 1220×700×225 1220×700×225 1220×700×225 1220×700×225 1420×700×245 1420×700×245

Net weight kg 40 40 40 40 50 50

Model WVF90GDCAUO WVF112GDCAUO WVF125GDCAUO WVF140GDCAUO WVF160GDCAUO

Cooling capacity kW 9.0 11.2 12.5 14.0 16.0

Heating capacity kW 10.0 12.5 14.0 16.0 18.0

Air volume m3/h 1600 2000 2000 2000 2300

Cooling power input W 140 160 160 160 200

Cooling current input A 1.1 1.4 1.4 1.4 1.9

Heating power input W 140 160 160 160 200

Heating current input A 1.1 1.4 1.4 1.4 1.9

Minimum line current A 1.17 1.5 1.5 1.5 2

Maximum fuse current A 6 6 6 6 6

Sound pressure level dB(A) 50 51 52 52 52

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52


Piping interface
Gas pipe mm Ø15.9 Ø15.9 Ø15.9 Ø15.9 Ø19.05

External
Drain pipe mm Ø17×1.5 Ø17×1.5 Ø17×1.5 Ø17×1.5 Ø17×1.75
diameter × thickness

Outline Dimensions W×D×H mm 1420×700×245 1700×700×245 1700×700×245 1700×700×245 1700×700×245

Net weight kg 50 60 60 60 60

Notes:
1. Rated cooling capacity test conditions: indoor 27°C DB/19°C WB, outdoor 35°C DB; connection pipe length: 5 m, without height drop
between units.
2. Rated heating capacity test conditions: indoor 20°C DB, outdoor 7°C DB/6°C WB; connection pip length: 5 m, without height drop between
units.

56 | VRF Indoor Unit


2.5 Slim Duct Type

Model WVDL22GDCBUO WVDL25GDCBUO WVDL28GDCBUO WVDL32GDCBUO WVDL36GDCBUO WVDL40GDCBUO

Horse Power HP 1 1 1 1.5 1.5 1.5

Cooling capacity kW 2.2 2.5 2.8 3.2 3.6 4.0

Heating capacity kW 2.5 2.8 3.2 3.6 4.0 4.5

Air volume m3/h 450 450 450 550 550 750

Unit external static pressure Pa 0/0~15 0/0~15 0/0~15 0/0~15 0/0~15 0/0~15

Cooling power input W 25 25 25 30 30 35

Cooling current input A 0.2 0.2 0.2 0.3 0.3 0.3

Heating power input W 25 25 25 30 30 35

Heating current input A 0.2 0.2 0.2 0.3 0.3 0.3

*Minimum line current A 0.25 0.25 .25 0.38 0.38 0.38

*Maximum fuse current A 6 6 6 6 6 6

Sound pressure level dB(A) 30 30 30 31 31 33

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35


Piping interface
Gas pipe mm Ø9.52 Ø9.52 Ø9.52 Ø12.7 Ø12.7 Ø12.7

External
Drain pipe mm Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5
diameter × thickness

Dimensions W×D×H mm 710×450×200 710×450×200 710×450×200 710×450×200 710×450×200 1010×450×200

Net weight Main body kg 18.5 18.5 18.5 19.5 19.5 23.5

Model WVDL45GDCBUO WVDL50GDCBUO WVDL56GDCBUO WVDL63GDCBUO WVDL72GDCBUO

Horse Power HP 2 2 2 3 3

Cooling capacity kW 4.5 5.0 5.6 6.3 7.2

Heating capacity kW 5.0 5.6 6.3 7.0 8.0

Air volume m3/h 750 750 850 850 1100

Unit external static pressure Pa 0/0~15 0/0~15 0/0~15 0/0~15 0/0~15

Cooling power input W 35 35 45 45 50

Cooling current input A 0.3 0.3 0.3 0.3 0.5

Heating power input W 35 35 45 45 50

Heating current input A 0.3 0.3 0.3 0.3 0.5

*Minimum line current A 0.38 0.38 0.38 0.38 0.63

*Maximum fuse current A 6 6 6 6 6

Sound pressure level dB(A) 33 33 35 35 37

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø6.35 Ø6.35 Ø9.52 Ø9.52 Ø9.52


Piping interface
Gas pipe mm Ø12.7 Ø12.7 Ø15.9 Ø15.9 Ø15.9

External diameter ×
Drain pipe mm Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5
thickness

Dimensions W×D×H mm 1010×450×200 1010×450×200 1010×450×200 1010×450×200 1310×450×200

Net weight Main body kg 23.5 23.5 24.5 24.5 30.5

VRF Indoor Unit | 57


Model WVDL22GDCB1UO WVDL25GDCB1UO WVDL28GDCB1UO WVDL32GDCB1UO WVDL36GDCB1UO WVDL40GDCB1UO

Horse Power HP 1 1 1 1.5 1.5 1.5

Cooling capacity kW 2.2 2.5 2.8 3.2 3.6 4.0

Heating capacity kW 2.5 2.8 3.2 3.6 4.0 4.5

Air volume m3/h 610 610 610 620 650 810

Unit external static pressure Pa 10/30 10/30 10/30 10/30 10/30 10/30

Cooling power input W 65 65 65 65 65 65

Cooling current input A 0.3 0.3 0.3 0.3 0.3 0.3

Heating power input W 65 65 65 65 65 65

Heating current input A 0.3 0.3 0.3 0.3 0.3 0.3

*Minimum line current A 0.63 0.63 0.63 0.63 0.63 0.63

*Maximum fuse current A 1.1 1.1 1.1 1.1 1.1 1.1

Sound pressure level dB(A) 38 38 38 38 38 38

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35


Piping interface
Gas pipe mm Ø9.52 Ø9.52 Ø9.52 Ø12.7 Ø12.7 Ø12.7

External
Drain pipe mm Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5
diameter × thickness

Dimensions W×D×H mm 710×450×200 710×450×200 710×450×200 710×450×200 710×450×200 1010×450×200

Net weight Main body kg 19.0 19.0 19.0 20.0 20.0 24.0

Model WVDL45GDCB1UO WVDL50GDCB1UO WVDL56GDCB1UO WVDL63GDCB1UO WVDL71GDCB1UO

Horse Power HP 2 2 2 3 3

Cooling capacity kW 4.5 5.0 5.6 6.3 7.1

Heating capacity kW 5.0 5.6 6.3 7.0 8.0

Air volume m3/h 810 810 810 810 1210

Unit external static pressure Pa 10/30 10/30 10/30 10/30 10/30

Cooling power input W 65 65 65 65 70

Cooling current input A 0.3 0.3 0.3 0.3 0.32

Heating power input W 65 65 65 65 70

Heating current input A 0.3 0.3 0.3 0.3 0.32

*Minimum line current A 0.63 0.63 0.63 0.63 0.63

*Maximum fuse current A 1.1 1.1 1.1 1.1 1.1

Sound pressure level dB(A) 37 37 37 37 39

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø6.35 Ø6.35 Ø9.52 Ø9.52 Ø9.52


Piping interface
Gas pipe mm Ø12.7 Ø12.7 Ø15.9 Ø15.9 Ø15.9

External
Drain pipe mm Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5
diameter × thickness

Dimensions W×D×H mm 1010×450×200 1010×450×200 1010×450×200 1010×450×200 1310×450×200

Net weight Main body kg 24.0 25.0 25.0 25.0 30.5

Notes:
1. Rated Cooling capacity test conditions: indoor 27°C DB/19°C WB, outdoor 35°C DB; connection pipe length: 5 m, without height drop
between units
2. Rated heating capacity test conditions: indoor 20°C DB, outdoor 7°C DB/6°C WB; connection pipe length: 5 m, without height drop between
units
3. In the column of “Unit external static pressure”: The figure before “/” indicates the default external static pressure of unit before delivery, and
the figures after indicate the adjustable static pressure range of unit.

58 | VRF Indoor Unit


1.6 Wall Mounted Type Indoor Unit

Features Characteristic

• Filter can be cleaned


The filter is removable and can be cleaned for easy maintenance.

• Quiet design
High-efficiency cross flow blade and imported silence valve are adopted,
which greatly reduce the noise of entire unit.

• One IDU with several wired controller and several IDUs with one wired
controller
One IDU can be connected with several wired controllers in order to control
one IDU from different location; meanwhile, several IDUs can be connected
with one wired controller in order to achieve centralized control of 16 IDUs
in maximum.

• Wide air supply range


The air supply range is wide, so that the wind can be delivered to each
corner of the room naturally and evenly.

• Super cooling and heating function


Intelligent temperature control technology is adopted with super cooling
and heating function, so that the room temperature can reach set
temperature rapidly.

• I-feel function
When I-feel function is activated, the unit can detect the temperature
around the user and adjust the temperature, so that the comfort of user is
improved. (Remote controller shall be equipped)

• Panel is removable
The panel of indoor unit can be removed easily for convenient maintenance.
The response of the system is quicker with more reliable communication,
auto addressing, non-polar communication and free wiring are available.

• Multiple protections
Anti-freezing protection, temperature sensor malfunction protection, fan
motor overload protection.

VRF Indoor Unit | 59


2.6 Wall Mounted Type

Model WVS22GCA3APO WVS28GCA3APO WVS36GCA3APO WVS45GCA3APO

Horse Power HP 1 1 1.5 2

Cooling capacity kW 2.2 2.8 3.6 4.5

Heating capacity kW 2.5 3.2 4.0 5.0

Air volume m3/h 500 500 630 630

Cooling power input W 50 50 60 60

Cooling current input A 0.2 0.2 0.31 0.31

Heating power input W 50 50 60 60

Heating current input A 0.2 0.2 0.31 0.31

*Minimum line current A 0.25 0.25 0.38 0.38

*Maximum fuse current A 6 6 6 6

Sound pressure level dB(A) 38 38 44 44

Power supply 220-240V 1phase ~50Hz

Liquid pipe mm Ø6.35 Ø6.35 Ø6.35 Ø6.35


Piping interface
Gas pipe mm Ø9.52 Ø9.52 Ø12.7 Ø12.7

External
Drain pipe mm Ø20×1.5 Ø20×1.5 Ø20×1.5 Ø20×1.5
diameter × thickness

Dimensions W×D×H mm 843×180×275 843×180×275 940×200×298 940×200×298

Net weight Main body kg 10.0 10.0 12.5 12.5

Notes:
1. Rated cooling capacity test conditions: indoor 27°C DB/19°C WB, outdoor 35°C DB; connection pipe length: 5 m, without height drop
between units.
2. Rated heating capacity test conditions: indoor 20°C DB, outdoor 7°C DB/6°C WB; connection pipe length: 5 m, without height drop between
units.

Model WVS50GCA3APO WVS56GCA3APO WVS63GCA3APO WVS71GCA3APO

Horse Power HP 2 2 3 3

Cooling capacity kW 5.0 5.6 6.3 7.1

Heating capacity kW 5.8 6.3 7.0 7.5

Air volume m3/h 630 750 750 750

Cooling power input W 60 70 70 70

Cooling current input A 0.31 0.31 0.31 0.31

Heating power input W 60 70 70 70

Heating current input A 0.31 0.31 0.31 0.31

*Minimum line current A 0.38 0.5 .05 0.5

*Maximum fuse current A 6 6 6 6

Sound pressure level dB(A) 44 44 44 44

Power supply 220-240V 1phase~50Hz

Liquid pipe mm Ø6.35 Ø9.52 Ø9.52 Ø9.52


Piping interface
Gas pipe mm Ø12.7 Ø15.9 Ø15.9 Ø15.9

External
Drain pipe mm Ø20×1.5 Ø20×1.5 Ø20×1.5 Ø20×1.5
diameter × thickness

Dimensions W×D×H mm 940×200×298 1008×221×319 1008×221×319 1008×221×319

Net weight Main body kg 12.5 15.0 15.0 15.0

Notes:
1. Rated cooling capacity test conditions: indoor 27°C DB/19°C WB, outdoor 35°C DB; connection pipe length: 5 m, without height drop between
units.
2. Rated heating capacity test conditions: indoor 20°C DB, outdoor 7°C DB/6°C WB; connection pipe length: 5 m, without height drop between
units.

60 | VRF Indoor Unit


1.7 Fresh air Processing Type Indoor Unit

Features Characteristic
• Fresh Air Processing Indoor Unit. Airflow volume: 1000m³/h~4000m³/h.
Applicable range: Residential houses, villas, business buildings, hotels,
apartments, etc.

• One system, two functions.


Adopted with DC inverter technology, Fresh Air Multi VRF System features
air conditioning function and fresh air function.

• Enjoy fresh air.


• Less investment.
Fresh Air Multi VRF System can be combined with Westinghouse Multi W5.
For a same room, if the same amount of fresh air is to be taken, then the
cost of Multi W5+Fresh air unit is equivalent to the cost of Multi W5+Air
exchange fan.
• Less operation cost.
Unit can control refrigerant output according to actual needs to ensure
constant airflow temperature. By adjusting power output, light-load but
high power operation can be avoided. Thus, operation cost can be greatly
reduced.

• Less installation space.


Save installation space for outdoor units. Especially suitable for places that
have restricted installation space.

1.8 Console Type IDU

Features Characteristic
• Multiple fan speed
The fan can operate in multiple speed and satisfy different air flow volume
requirements.

• Detachable grille and long life filter


Grille is detachable for easy cleaning. With long life filter, cleaning cycle is 20
times longer.

• Protection function
Anti-freezing protection, fan motor overload protection, temperature
sensor malfunction protection, auxiliary electric heating overheat protection
(This function is not included in pure heat pump unit).

1.9 Floor Standing Type Indoor Unit

Features Characteristic

• Wide Application
It can be widely adopted in hotels, restaurants,office,etc.

• Auto clean to ensure a healthy life


After turning off the unit, the indoor fan will keep running in low speed for
a moment to dry the inner components and parts, in order to prevent mildew
and keep user healthy.

VRF Indoor Unit | 61


2.7 Fresh Air Processing Unit

Model WVD450GFCAVOX4.0

Cooling capacity kW 45

Heating capacity kW 32

Air volume m3/h 4000

Standard 200
Static pressure (Pa)
Optional 300

Cooling power input W 1240

Cooling current input A 3.40

Heating power input W 1240

Heating current input A 3.40

Minimum line current A 6.5

Maximum fuse current A 7.6

Sound pressure level dB(A) 58

Power supply 380~415V 3N~50Hz

Liquid pipe mm Ø12.7


Piping interface
Gas pipe mm Ø28.6

Drain pipe External diameter × thickness mm Ø33×3

Dimensions W×D×H mm 1700×1100×650

Net weight Main body kg 208

Notes:
1. Rated cooling capacity test conditions: fresh air inlet 35°C DB/28°C WB; connection pipe length: 5 m, without height drop between units; The
default air outlet temperature of the unit is 18°C.
2. Rated heating capacity test conditions: fresh air inlet 7°C DB/6°C WB; connection pipe length: 5 m, without height drop between units; The
default air outlet temperature of the unit is 22°C.
3. This series can be matched with Multi W5 only. DC Inverter Fresh Air Processing Indoor

Model WVD125GFDCAUO1 WVD140GFDCAUO1 WVD224GFDCAUO1

Cooling capacity kW 12.5 14.0 22.4

Heating capacity kW*1 8.5 10.0 16.0

kW*2 10.5 12.0 20.0

Air volume m3/h 1200/1000~2000 1200/1000~2000 2000/2000~3500

Standard 150 150 200


Static pressure (Pa)
Optional 50~200 50~200 50~300

Cooling power input W 200 200 400

Cooling current inpu A 1.5 1.5 2.5

Heating power input W 200 200 400

Heating current input A 1.5 1.5 2.5

Minimum line current A 2.1 2.1 6.3

Maximum fuse current A 6 6 10

Sound pressure level dB(A) 40~50 40~50 45~54

Power supply 220-240V 1 phase ~50Hz 208-230V 1 phase ~60Hz

Liquid pipe mm Ø9.52 Ø9.52 Ø9.52


Piping interface
Gas pipe mm Ø15.9 Ø15.9 Ø19.05

External
Drain pipe mm Ø25×2.5 Ø25×2.5 Ø25×2
diameter × thickness

Dimensions W×D×H mm 1400×700×300 1400×700×300 1483×791×385

Net weight Main body kg 54 54 82

62 | VRF Indoor Unit


Notes:
1. Rated cooling capacity test conditions: indoor 35°C DB/28°C WB, outdoor 35°C DB; connection pipe length: 7.5m, without height drop
between units. The default air outlet temperature of the unit is 18°C.
2. Rated heating capacity test conditions: *1:indoor 7°C DB, outdoor 7°C DB/6°C WB, *2: indoor -7°C DB, outdoor 0°C DB / -2.9°C WB;
connection pipe length: 7.5m, without height drop between units. The default air outlet temperature of the unit is 22°C.
3. In the column of “Air Volume”: The figure before “/” indicates the default air Volume of unit before delivery, and the figures after indicate the
adjustable air Volume range of unit.
4. The sound pressure level will change with the static pressure.
5. This series can be matched with Multi W5 only.

Model WVD250GFDCAUO1 WVD280GFDCAUO1

Cooling capacity kW 25.0 28.0

kW*1 18.0 20.0


Heating capacity
kW*2 20.0 22.0

Air volume m3/h 2500/2000~3500 2500/2000~3500

Standard 200 200


Static pressure (Pa)
Optional 50~300 50~300

Cooling power input W 520 520

Cooling current input A 3.1 3.1

Heating power input W 520 520

Heating current input A 3.1 3.1

Minimum line current A 6.3 6.3

Maximum fuse current A 10 10

Sound pressure level dB(A) 47~54 47~54

Power supply 220-240V 1 phase ~50Hz 208-230V 1 phase ~60Hz

Liquid pipe mm Ø9.52 Ø9.52


Piping diameter
Gas pipe mm Ø22.2 Ø22.2

Drain pipe External diameter × thickness mm Ø25×2 Ø25×2

Outline Dimensions W×D×H mm 1483×791×385 1483×791×385

Net weight kg 82 82

Notes:
1. Rated cooling capacity test conditions: indoor 35°C DB/28°C WB, outdoor 35°C DB; connection pipe length: 7.5m, without height drop
between units. The default air outlet temperature of the unit is 18°C.
2. Rated heating capacity test conditions: *1:indoor 7°C DB/6°C WB, outdoor 7°C DB/6°C WB, *2: indoor 0°C DB / -2.9°C, outdoor 0°C DB /
-2.9°C WB; connection pipe length: 7.5m, without height drop between units. The default air outlet temperature of the unit is 22°C.
3. In the column of “Air Volume”: The figure before “/” indicates the default air Volume of unit before delivery, and the figures after indicate the
adjustable air Volume range of unit.
4. The sound pressure level will change with the static pressure.
5. This series can be matched with Multi W5 only Fresh air series indoor unit has two kinds of connection according to different models:

(1) The following models can be connected to the same outdoor unit with conventional VRF indoor units.

Model of Indoor Unit Model of Outdoor Unit

WVD125GFDCAUO1

WVD140GFDCAUO1 Connecting condition with Multi W-**WM/B-F (or Multi W-**WM/B-U; or Multi W-**WM/E-X) series modular outdoor
unit: The total capacity of connected fresh air series indoor units and conventional VRF indoor units must be within
WVD224GFDCAUO1 50%~100% of the capacity of outdoor unit, among which, the total capacity of connected fresh air indoor units cannot
exceed 30% of the capacity of outdoor unit. Fresh air indoor units can operate independently. The total capacity of
WVD250GFDCAUO1 connected fresh air indoor units cannot exceed 50%~100% of the capacity of outdoor unit.

WVD280GFDCAUO1

1 :The fresh air volume≤2500m3/h


Notes: When fresh air series indoor units and conventional VRF indoor units will be connected, please
follow the capacity requirement strictly. The total capacity of connected fresh air indoor units cannot exceed 30% of the capacity of outdoor unit,
while the total capacity of indoor units shall be within 50%~100% of the capacity of outdoor unit. Otherwise, the comfortableness will be affected
or even the unit will be damaged.

VRF Indoor Unit | 63


2.8 Console Type

Model WVON22GDCAUO WVON28GDCAUO WVON36GDCAUO WVON45GDCAUO WVON50GDCAUO

Horse Power HP 1 1 1.5 2 2

Cooling capacity kW 2.2 2.8 3.6 4.5 5.0

Heating capacity kW 2.5 3.2 4.0 5.0 5.5

Air volume m3/h 400 400 480 680 680

Cooling power input W 15 15 20 40 40

Cooling current input A 0.17 0.17 0.25 0.4 0.4

Heating power input W 15 15 20 40 40

Heating current input A 0.17 0.17 0.25 0.4 0.4

*Minimum line current A / / / / /

*Maximum fuse current A / / / / /

Sound pressure level dB(A) 38 38 40 46 46

Power supply 220-240V 1phase ~50Hz 208-230V 1phase ~60Hz

Liquid pipe mm Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35


Piping interface
Gas pipe mm Ø9.52 Ø9.52 Ø12.7 Ø12.7 Ø12.7

External
Drain pipe mm Ø28×1 Ø28×1 Ø28×1 Ø28×1 Ø28×1
diameter × thickness

Dimensions W×D×H mm 700×215×600 700×215×600 700×215×600 700×215×600 700×215×600

Net weight Main body kg 16 16 16 16 16

2.9 Floor Standing Type

Model WVFS100GDCAUO WVFS140GDCAUO

Cooling capacity kW 10 14

Heating capacity kW 11 15

Air volume m3/h 1850 1850

Cooling power input W 200 200

Cooling current input A 1.5 1.5

Heating power input W 200 200

Heating current input A 1.5 1.5

Minimum line current A / /

Maximum fuse current A / /

Sound pressure level dB(A) 50 50

Power supply 220-240V 1phase ~50Hz 208-230V 1phase ~60Hz

Liquid pipe mm Ø9.52 Ø9.52


Piping interface
Gas pipe mm Ø15.9 Ø15.9

Drain pipe External diameter × thickness mm Ø31×4.5 Ø31×4.5

Dimensions W×D×H mm 1870×580×400 1870×580×400

Net weight Main body kg 54 57

64 | VRF Indoor Unit


1.10 Compact Four-way Cassette Type Indoor Unit

Features Characteristic
• Compact design for easy installation.
Units maintain the uniform length and width with consistent ceiling opening
and panel dimension, convenient for design and installation.

• Ultra-low noise operation.


DC inverter motor can realize stepless speed regulation to lower noise.
Indoor unit can be set to work under anto quiet mode via wired controller.

• Intelligent drainage device.


Water height difference up to 1.0m, which can effectively drain out
condensing water and save space.

1.11 AHU-KIT Type

Features Characteristic
• Can be conveniently controlled via the third party controller.
AHU-KIT adapter can be controlled via Westinghouse wired controller, and
can also be controlled via the third party controller by adjusting dial code,
which can realize ON/OFF control, mode setting, temperature adjustment,
feedback of unit operating status, etc.

• Make the air handling unit is with functions and advantages of VRF products
. Connected to VRF system of air handling unit and retained the original user
function and project application function of VRF system. Installation,
debugging, operation and maintenance are more convenient.

• Multiple installation method for convenient project design.


The air handling unit equipped with AHU-KIT has multiple methods for
connecting VRF system. It can independently connect to VRF system to
compose a one-to-one proposal; it can also match with other air handling
unit or general VRF indoor units to connect to the same VRF system for
composing a one-to-more proposal. In this case, it is convenient for project
design.

• Independent design, convenient installation.


AHU-KIT is composed by two independent boxs (electronic expansion valve
and control box) and designed independently, which is convenient for
installation and application.

• Error signal is connected for reliable installation and operation.


Error signal of air handling unit is connected to AHU-KIT. Where there’s
malfunction, the unit will stop operation, same and reliable.

• Dual control ways


It can be controlled according to normal indoor unit and also according to
fresh air indoor unit.

VRF Indoor Unit | 65


2.10 Compact Four-way Cassette Type

Model WVCC22GDC- WVCC28GDC- WVCC36GDC- WVCC45GDC- WVCC50GDC- WVCC56GDC-


BUO BUO BUO BUO BUO BUO

Cooling capacity kW 2.2 2.8 3.6 4.5 5.0 5.6

Heating capacity kW 2.5 3.2 4.0 5.0 5.6 6.3

Air volume m3/h 600 600 600 700 700 700

Cooling power input W 35 35 35 45 45 45

Cooling current input A 0.4 0.4 0.4 0.5 0.5 0.5

Heating power input W 35 35 35 45 45 45

Heating current input A 0.4 0.4 0.4 0.5 0.5 0.5

Minimum line current A 0.5 0.5 0.5 0.63 0.63 0.63

Maximum fuse current A 6 6 6 6 6 6

Sound pressure level dB(A) 41 41 41 45 45 45

Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz

Liquid pipe mm Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø9.52


Piping interface
Gas pipe mm Ø9.52 Ø9.52 Ø12.7 Ø12.7 Ø12.7 Ø15.9

External
Drain pipe mm Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5 Ø25×2.5
diameter × Thickness

Main body dimensions W×D×H mm 596×596×240 596×596×240 596×596×240 596×596×240 596×596×240 596×596×240

Panel dimensions W×D×H mm 670×670×50 670×670×50 670×670×50 670×670×50 670×670×50 670×670×50

66 | VRF Indoor Unit


1.12 Two-way Cassette Type Indoor Unit

Features Characteristic
• Beautiful Appearance.
With beautiful and elegant front panel, it is congenial to the indoor
surroundings.
• Two-way air flow design.
Two-way air outlet, to stretch air outlet distance and solve air supply
problem of elongated room.
• Intelligent drainage device.
Water height difference up to 1.0m, which can effectively drain out
condensing water and save space.
• Multiple protections.
Anti-freezing protection, temperature malfunction protection, fan
motor overload and humidity sensor protection.

1.13 Air Handler type Indoor Unit

Features Characteristic
• Highly flexible installation.
The unit is designed for outdoor installation and less indoor space
taking, allowing easy installation and maintenance. The unit can be installed
on the ground or on the roof of the buildind, which means the installation is
totally flexible depending on the project requirement.

• Cold air prevention design.


When heating in winter, cold air prevention function is enabled so that air
won’t be blown out until it’s warm.

• Long life and washable filter.


The filter is easy to be dismantled and installed. You can use dust collector
or water to clear away the dust.

1.14 Two-way Cassette Type Indoor Unit

Features Characteristic
• High static pressure design.
Static pressure can be up to 200Pa(0.8 In.W.G), especially suitable for places
in need of long distance airflow.

• Convenient installation.
You can choose circular air duct or rectangular air duct according to actual
needs. Or you can choose different ways of air return.

• Easy maintenance.
The system has maintenance port for easy maintenance.

• Protection function.
Anti-freezing protection, fan motor overload protection, temperature
sensor malfunction protection.
1.15 Concealed Floor Standing Type Indoor Unit

Features Characteristic
• Wide capacity range from 2.2kW to 7.1kW

• DC motor is adopted, which is more efficient.

• All units are only 200mm’s thick, saving space while offering highly efficient
performance.

• High ESP allows installation with air ducts.

• The low altitude design allows installation under a window. It is applicable


for hotels, schools and office buildings.

• The three different height choices of ex-factory supporter satisfy users


different installation needs.

1.16 360°Air Discharge Compact Casssette Indoor Unit

Features Characteristic
• 360° Air Supply.
360°air supply design for balanced temperature distribution, which provides
more comfortable experience.

• Independent Swing Control.


4 swing blades can be controlled independently and maximum 625 air supply
angle combinations can be realized for free and humanized control, avoiding
direct blow to people.

• Ultra-low Noise Operation.


DC inverter motor can realize stepless speed regulation to lower noise indoor
unit, it can be set to work under auto quiet mode via wired controller.

• Intelligent Drainage Device.


Water height difference up to 1.2m, which can effectively drain out
condensing weter and save space.

68 | VRF Indoor Unit VRF Indoor Unit | 67


(2) The following models of indoor unit only can be connected in a fixed combinatio

Model of Indoor Unit Model of Outdoor Unit

WVD450GFCAVOX4.0 WVC450WECG3T2S

WVD224GFDCAUO2 WVC224WECG3T2S

WVD250GFDCAUO2 WVC280WECG3T2S

WVD280GFDCAUO2 WVC280WECG3T2S

2 :The fresh air volume > 2500m3/h


Note: “-F” is for the power specification of 208/230V 3~ 60Hz; “-U” is for the power specification of 440-460V 3~ 60Hz; “-X” is for the power
specification of 380-415V 3N~ 50/60Hz.

(3) For example:


1) Customer select Multi W-NDX280P/A-T model. After the unit is installed, the fan static pressure is 200Pa. The required air volume by the
customer is 3000m3/h, the corresponding static notch on the curve diagram between air volume and static pressure is notch 09. Because the
air volume is more than 2500m3/h, it needs to adopt the second fixed connection method, matching Multi W-280WM/B-F(or Multi W-280WM/
B-X) outdoor unit.
2) Customer select Multi W-NDX224P/A-T model. After the unit is installed, the fan static pressure is 150Pa. The required air volume by the
customer is 2300m3/h, the corresponding static notch on the curve diagram between air volume and static pressure is notch 05. Because the
air volume is less than 2500m3/h, it can adopt first connection method or the second fixed connection method by matching Multi W-224WM/B-
F(or Multi W-224WM/B-X) outdoor unit.
WESTINGHOUSE, and INNOVATION YOU CAN BE SURE OF are
trademarks of Westinghouse Electric Corporation.
Used under license by Westinghouse Air Conditioning and Electron-
ics Middle East and Africa FZE
All Rights Reserved.

CONTACT US
Westinghouse Air Conditioning and Electronics Middle East and
Africa FZE
LB08025, JAFZA, Dubai, United Arab Emirates
Tel : +971 42 669 681 | Fax : +971 43 290 670
E-mail : contact@westinghousemea.com

You might also like