ﺗﻤﺮﻳﻦ -1ﭘﺨﺶ ﺑﺎر ﻫﺎرﻣﻮﻧﻴﻜﻲ
nt
ile
-1ﻓﺼﻞ ﻫﺸﺘﻢ ﺗﺤﻠﻴﻞ ﻫﺎرﻣﻮﻧﻴﻜﻲ دﺳﺘﻮر ﻛﺎر آزﻣﺎﻳﺸﮕﺎه را اﻧﺠﺎم دﻫﻴﺪ )ﺗﺎ ﺑﺨﺶ (3-8
gs
-2ﺑﺮاي ﻳﻜﻲ از ﺑﺎس ﺑﺎرﻫﺎ ﺑﻪ ﻏﻴﺮ از ﺑﺎس ﺑﺎر 4ﻛﻪ در اداﻣﻪ ﻧﺸﺎن داده ﺷﺪه اﺳﺖ ﻣﺮاﺣﻞ زﻳﺮ را ﺑﺎ ﻣﺎﺷﻴﻦﺣﺴﺎب و
nt .di
ﻧﺮماﻓﺰار دﻳﺠﺴﺎﻳﻠﻨﺖ ،ﺗﻜﺮار ﻛﻨﻴﺪ.
ile sy
-3ﺑﺮاي ﺑﺎس ﻣﻮرد ﻧﻈﺮ ،ﭘﺎراﻣﺘﺮﻫﺎي زﻳﺮ را ﻣﺎﻧﻨﺪ ﺷﻜﻞ ) (1اﺿﺎﻓﻪ ﻛﻨﻴﺪ) .وﻟﺘﺎژ ﺑﺎس ﺧﻂ ﺑﻪ ﺧﻂ اﺳﺖ(
gs a
Bus4
di /e
u=0.14 p.u.
sy om
THD=68.83 %
THD=28.43 % Ulrms=272.02 kV
THD=63..
ea .c
TP=88.0660 MW urms=1.18 p.u.
TQ=81.12 Mvar
e/ am TS=119.73 MVA
Tcosphi=0.74
t.m gr
HD=5.26 %
I=12.865 A
:// ta
Irms=254.1253 A
tp ns
THD=10..
ht w.i
Load4
w
/
nt
را رﺳﻢ ﻛﻨﻴﺪ4 ﻣﻮﻫﻮﻣﻲ ﺑﺎس ﺑﺎر
ile
DIgSILENT
500.00 200.00 250.00
gs
400.00 100.00 200.00
nt .di
300.00 0.00 150.00
ile sy
200.00 -100.00 100.00
gs a
di /e
100.00 -200.00 50.00
sy om
0.00 -300.00 0.00
1.00 5.00 11.0 17.0 1.00 5.00 11.0 17.0 1.00 5.00 11.0 17.0
Load4: Current, Magnitude in A Load4: Angle between Voltage and Current in deg Bus4: Ul, Magnitude in kV
4.00E+4 300.00
ea .c
3.00E+4
e/ am 0.00
2.00E+4 -300.00
t.m gr
1.00E+4 -600.00
:// ta
tp ns
0.00E+0 -900.00
ht w.i
-1.00E+4 -1200.00
1.00 5.00 11.0 17.0 5.0000 11.000 17.000
Load4: Reactive Power in kvar Load4: Active Power in kW
/
nt
ﺟﺪول -1اﻃﻼﻋﺎت ﺗﻜﻤﻴﻠﻲ ﺑﺎس ﺑﺎر ) 4ﻣﺤﺎﺳﺒﻪ ﺷﺪه و ﺑﺪﺳﺖ آﻣﺪه از ﺷﻜﻞ (2
ile
1 2 3 4 5 6 7
gs
ﺷﻜﻞ 2و ﺷﻜﻞ 2و
داده ﺷﺪه داده ﺷﺪه ﺷﻜﻞ 2 ﺷﻜﻞ 2 ﺷﻜﻞ 2
nt .di
ﻓﺮﻣﻮل 1-6 ﻓﺮﻣﻮل 2-6
f )HD (% )If (A )Vf(kv)(LL )(fi)-V-I (deg )Pf(MW )Qf(Mvar
ile sy
1 100% 244.44 224.072 18.435 89.9998 30.0000
gs a
5 20% 48.888 67.166 -91.221 -0.12119 -5.6861
di /e
7 14.285% 34.918 31.906 91.729 -0.058222 1.92878
11 9.09% 22.220 115.868 -104.102 -1.0865 -4.32492
sy om
13 7.692% 18.802 61.876 -106.971 -0.5881 -1.9273
17 5.882% 14.378 5.704 -102.957 -0.03185 -0.13843
ea .c
19 5.263% 12.865 31.149 93.974 -0.048103 0.692419
e/ am
-6ﻣﺸﺎﺑﻪ ﻓﺮﻣﻮلﻫﺎي ﻓﺼﻞ ﻫﺸﺘﻢ ﮔﺰارشﻛﺎر ،در اداﻣﻪ ،ﭘﺎراﻣﺘﺮﻫﺎي زﻳﺮ ﺑﺎ ﻣﺎﺷﻴﻦﺣﺴﺎب ﻣﺤﺎﺳﺒﻪ ﺷﺪه و ﺑﺎ
t.m gr
دﻳﺠﺴﺎﻳﻠﻨﺖ )ﺷﻜﻞ 1و (2ﻣﻘﺎﻳﺴﻪ ﺷﺪه و دﻗﺖ ﻣﺤﺎﺳﺒﺎت ﻗﺎﺑﻞﻗﺒﻮل اﺳﺖ .ﭘﺎراﻣﺘﺮﻫﺎي ﻣﺤﺎﺳﺒﻪ ﺷﺪه ﻋﺒﺎرتاﻧﺪ از:
:// ta
/
nt
ile
: ﺟﺮﻳﺎن ﻣﺆﺛﺮ-3-6
gs
Root mean square value:
nt .di
i =∞
I rms = ∑I 2
fi =
ile sy
i =1
gs a
di /e
= 254.125
sy om
ea .c
e/ am : وﻟﺘﺎژ ﻣﺆﺛﺮ-4-6
i =∞
V rms = ∑V 2
=
t.m gr
fi
i =1
:// ta
= 272.019
ht w.i
w
w
/
nt
ile
:( ﻣﺤﺎﺳﺒﻪ اﻋﻮﺟﺎج ﻫﺎرﻣﻮﻧﻴﻚ ﻛﻞ ﺟﺮﻳﺎن )ﺑﺮاي وﻟﺘﺎژ ﻫﻢ ﻣﺤﺎﺳﺒﻪ ﻛﻨﻴﺪ-5-6
gs
Total harmonic distortion:
n t .d i
i =∞
1
THD = ∑I f
2
=
ile sy
I fn i =2
gs a
1
= (48.888) 2 + (34.918) 2 + (22.220) 2 + (18.802) 2 + (14.378) 2 + (12.865) 2
di /e
244.44
sy om
= 28.428%
ea .c
e/ am
t.m gr
: ﻛﻞ ﺗﻮان ﺣﻘﻴﻘﻲ-6-6
:// ta
i =∞
TP = ∑Pfi =
ht w.i
i =1
= 88.0658
w
/
nt
ile
gs
nt .di
: ﺗﻮان ﻇﺎﻫﺮي ﻛﻠﻲ-7-6
ile sy
Total Apparent Power:
TS = 3 ×U rms × I rms = 3 × 272.019 × 254.125 = 119.731
gs a
di /e
sy om
: ﺗﻮان ﻣﻮﻫﻮﻣﻲ ﻛﻠﻲ:-8-6
ea .c
Total Reactive Power: e/ am
TQ = TS 2 − TP 2 = (119.731) 2 − (88.0658) 2 = 81.1167
t.m gr
:// ta
tp ns
TP 88.0658
T cos ϕ = = = 0.7355
w
TS 119.731
w