Professional Documents
Culture Documents
Comment Sheet-MNB - Ch-41+498 1x10x4m-19-7-22
Comment Sheet-MNB - Ch-41+498 1x10x4m-19-7-22
Sr.
Comments from DCSL Compliance from Design Director Remarks
No.
1 Slope of stone pitching shall be 2:1 in width direction as per SP GAD, DRG No. HELP-STR-MNB-
13:2004 according to Plate. GAD-03 (SH 01 OF 02)
In drawing, Bore log mentioned as VUP @Ch 27+030 at A1 site, GAD, DRG No. HELP-STR-MNB-
Please verify and correct. GAD-03 (SH 01 OF 02)
2 Kindly add the calculation for braking force as per IRC 6:2017 Cl. Design note MNB(1x10x4m)
211.2
3 Kindly apply the impact factor for Vehicular loading as per IRC Design note MNB(1x10x4m)
6:2017 Cl. 208
4 In design, Maximum stresses in steel at Top of Bottom Slab is Design, Page No. 26
338.2Mpa which is exceeding permissible stresses as 300Mpa
(taken to avoid fatigue check for rare combination as per IRC 112-
2011 Ammendment Oct 13, A-8). Kindly redesign and resubmit.
5 In design, Maximum crack width at Top of Bottom Slab is Design, Page No. 27
0.618mm which is exceeding permissible crack width as 0.3mm
for severe condition as per IRC 112, Table12.1. Kindly redesign
and resubmit.
6 In design, Maximum crack width at Side Wall Bottom Corner is Design, Page No. 41
0.496mm which is exceeding permissible crack width as 0.3mm
for severe condition as per IRC 112, Table12.1. Kindly redesign
and resubmit.