VEGA II

Electronic flow computer


One meter version 2.0
DS/VE/0016/EN Ed. May 2013

VEGA II is a calculator-indicating device intended to be used


in measuring systems for liquids other than water (MID MI-005)
approved by the notified body LNE (France) with the
Evaluation Certificate n.12081 (see Welmec guide 8.8).

Metrology characteristics:
 One meter, three products loading
 Suitable for interruptible and not-interruptible measuring
systems
• Accuracy class: 0.3
• Mechanical class: M2
• Electromagnetic class: E2
 Certification of software with the follow extensions (see
Welmec guide 7.2):
• Extension S (Software separation):
the metrological and automation parts of firmware
are divided; a specific CRC16 characterizes the legally
relevant software.
• Extension L (Long term data storage):
the delivery data are stored in a data structure (250 Functional characteristics:
deliveries)with MID criteria. The data can be
downloaded by serial lines or consulted on the display  ‘Drop down’ menu with extended descriptions
by specific tool.  The operator is guided step by step through menus
• Extension T (Legally relevant data transmission):  Alarms and incorrect operations are clearly described
the delivery data can be transmitted by a serial line to  Able to adapt to the many different levels of automation/
PC, to a Printing system or directly to a printer by configuration at loading bays worldwide
legally relevant protocols.  Management of bottom and top loading
 Linkable with a legally relevant printer ST500-M (ISOIL)  Management of preset valves (two stages, digital or
 Linkable with alibi recording device ISOIL MRD (Metrical analog valves)
Recording Device)  Manages the adjustment of the final quantity
 Legally Relevant ModBus communication for quantities,  Manages actions in cases of lack of interlock
density and temperature data acquisition.  Management of identification by pin-code
 Entrance to parameters protected by password (three  Direct control of up to two metered additives units
levels) and Weight and Measure switch  Direct control of up to two additives pistons
 Log parameters function  Control of additivation system (ISOIL FlexiMix)via RS485
 Continuous self-diagnosis serial communication interface
 Selection between the main units of measure (a “custom”
unit is available)
Hardware properties:  Temperature compensation according to ASTM/API
 Explosion proof execution Ex-d approved ATEX Tables
 Serial communication ports: n°2 EIA-RS485/RS232,  Acquisition of product temperature from temperature
n° 1 EIA-RS485/RS422, n°1 EIA-RS232 element “Pt100” three or four wires
 Modular electronic rack-type  Local (stand alone)or remote working (host controlled)
 Leds back-light graphic display with Proprietary ASCII or ModBuS (RTU) protocols
 Numeric and multi-function push-buttons, solid state  Direct management of print with configurable reports by
 Internal back-up battery a single printer or shared printer for several VEGA IIs.
 Internal heating device, with thermostat  Diagnostic applications (status verification D/I, A/I and
 Counting inputs configurable (encoders, push- pull and simulation of D/O, A/O)
OC signals, Namur)  N° 6 emergency functions (three programmable)
 Up to 32 digital inputs totally programmable  Terminal display managing: the system (TAS)can visualize
 Up to 16 power outputs programmable messages, data entry fields on the screen of VEGA II
 Up to 16 digital outputs programmable  Remote outputs managing: the system (TAS) can position
 n° 4 pulses outputs programmable the relays or digital outputs not used by serial message
 n° 2 analog input 4÷20 mA to acquire product density
 n° 2 analog outputs active 4÷20 mA for remote indication
of temperature or flow-rate

ISOIL IMPIANTI S.p.A. - 24061 Albano S. Alessandro (BG) - Italy


tel : +39.02.91988.5 fax: +39.02.66012457
web: www.isoilmeter.com e-mail: sales@isoil-impianti.it
DS/VE/0016/EN -05/13 Pag. 1/1
Features Temperature and pressure compensation (optional)
The compensation provides with the ability to compensate
Measuring unit for variance in temperature and pressure from a reference
VEGA II allows the display of fixed and processed quantity conditions: base temperature (typically at 15°C, 20°C and
calculations using the following units of measurement: 60°F) and base pressure defined as equilibrium pressure or
• volume can be expressed in litres, gallons (US,UK), cubic vapour pressure.
metres, cubic centimetres.
• mass can be expressed in grams, kilograms, pounds and VEGA II calculates the temperature compensated volume
tonnes. for:
Moreover, if the requirement is not included in the list • Petrochemical products using API chapter 11.1 (2004
above, the user can configure a customized unit of edition and 2007 addendum) tables or BRAZIL table.
measurement of a maximum of 8 alphanumeric characters. • NGL and LPG products using API chapter 11.2.4 (2007
Flow rate can be represented as a unit of measurement: edition) tables.
• /min (units of measure per minute) • Ethanol product using the following tables: OIML R22,
• /hour (units of measure per hour) NBR5992.
• Biofuels via "PTB table" for thermal compensation of
Quantities acquisition:
mixtures of mineral and bio fuels.
• Dual pulse counting
• other generic products by using the ALPHA cubic
VEGA II can be interfaced to standard dual pulses emitter.
expansion coefficient.
Acquisition is performed providing continuous monitoring
and error indicating alarm of pulses transmission
VEGA II calculates the temperature and pressure
according OIML R117 and ISO 6551 Level B, API Chapter
compensated volume for:
5.5 Level B.
• Petrochemical products using API chapter 11.1 (2004
• Encoder CanBus
edition and 2007 addendum) tables or BRAZIL table.
VEGA II allows to be linked with the ISOIL EM6422
• NGL and LPG products using API chapter 11.2.4 (2007
encoders via protected CanBus protocol in order to
edition) tables for temperature compensation (CTL) and
improve the immunity performance, safety from
API chapter 11.2.2 (1986 Edition) for pressure
manumission and diagnosis functions.
compensation (CPL). API chapter 11.2.5 tables is used
• ModBus protocol
for vapour pressure calculation.
VEGA II can be interfaced to electronic unit able to
transmit quantities information via serial line by ModBus
Volume to mass conversion
RTU protocol (for example Promass 84F E+H Coriolis mass
When datum acquired represents the volume the
meter). Specific parameters are used to set slave
calculation of mass is possible by:
address, registers number and data types.
• observed density if available
• gross standard volume (GSV) and density at reference
Density acquisition
condition (only for Vega compensating version).
VEGA II can acquire density via a 4÷20 mA input or via serial
line (ModBus RTU). It’s possible to select the types of data
Mass to volume conversion
represented in input as base density or as observed density
When datum acquired represents the mass the calculation
(ambient temperature).
of volume is possible by:
VEGA II, during the delivery, makes the calculation of
• observed density if available
product’s average density.
• gross standard volume (GSV) and density at reference
Density will be represented in kg/m3.
condition (only for Vega compensating version).
Pressure acquisition
Meter calibration
VEGA II can acquire pressure via a 4÷20mA input or via
VEGA II allows the following settings for each of up to three
serial line (ModBus RTU).
products:
VEGA II, during the delivery, makes the calculation of
• k-factor (impulses/unit of measurement, meter
product’s pressure and average equilibrium pressure.
characteristic factor)
Relative pressure can be represented in psig, barg and
• meter factor (“average” setting factor)
Kpag.
• the correction curve (up to 10 pairs of flow
rate/correction values to correct error throughout flow
Temperature acquisition
rate range).
The product temperature is measured by a Pt100 probe
connected with VEGA II. Alternatively temperature can e
acquired from a temperature probe via serial line (ModBus
RTU).
VEGA II, during the delivery, makes the calculation of
product’s average temperature.
Temperature will be expressed in °C or °F.

ISOIL IMPIANTI S.p.A. - 24061 Albano S. Alessandro (BG) - Italy


tel : +39.02.91988.5 fax: +39.02.66012457
web: www.isoilmeter.com e-mail: sales@isoil-impianti.it Pag. 2/2
DS/VE/0016/EN -05/13
Loading operations: • Analog valve (4÷20mA)
VEGA II, in local mode, manages the loading process Vega II is able to drive any valve with suitable hydraulic
according to the configuration of the functions enabled, characteristics by the 4÷20mA signal. The delivery phases
carrying out the following operations: and flow rate values are managed as for the digital
• selecting of product (when more products are available) valve.
by keyboard or external selector.
• selecting type of loading (top or bottom) using the Configuring digital inputs and outputs
external selector (when both top & bottom loading is The firmware is designed to allow maximum flexibility in
available). adapting to devices and field signals.
• controlling interlocks, signals positioning. For example the various VEGA II at a loading terminal can be
• setting preset from keyboard or external selector. configured for loading bays with different characteristics and
• starting delivery from keyboard or external button. input/output signals.
• opening selector, block and vapour recovery valves, All digital inputs (up to 32) can be programmed as loading
starting pump and preset valves according to times interlock or signal linked to a specific function.
specified by appropriate parameters. If configured as interlock you can select:
• enabling additive system • logic level (ok if closed, ok if open)
• managing loading process by means of preset valves. • type of load (top, bottom, top and bottom)
During this phase, VEGA II not only counts product but • action (functions to be enabled with possible configurable
also carries out flow rate, temperature and specific D/O control)
automation control operations. • label (signal meaning, displayed in full) including:
• closing preset valve, accurately when the preset quantity (Interlock number, grounding, bottom loading arm, top
has been delivered. loading arm, manual valve, bottom loading arm manual
• closing selector, block and vapour recovery valves, valve, top loading arm manual valve, vapour recovery
stopping pump according to times specified by the valve, bottom loading vapour recovery valve, top loading
appropriate parameters. vapour recovery valve, overfilling, bottom load overfilling,
• summarising data and printing delivery reports. top load overfilling, tank-truck presence, interlocks from
badge reader, dead man, dirty filter, emergency, bay
In remote mode VEGA II operates as an intelligent terminal locked, remote emergency, vapour recovery, tank level,
controlled by a TAS (Terminal Automation System); once right loading arm, left loading arm, right grounding unit,
initialised it continues working independently controlling the left grounding unit).
loading process by means of the devices it is connected to. Other three labels can be configured: for each custom
The TAS controls functions such as: interlock, 4 lines of 15 characters are available.
• operator recognition by means of “pin-code” or badge
entered and enabling loading. Whilst every input configured as a signal can be associated
• starting loading selecting methods (top, bottom, with a fixed function; you can select:
automatic, semiautomatic..), resetting quantity and • type of load (top, bottom, top & bottom)
updating density. • type of signal, including: (General signal, Remote start,
• starting and stopping delivery. remote start ATB preset, remote start ATK preset, remote
• enabling and disabling meter. stop, remote stop ATB preset, remote stop ATK preset,
• resetting alarm. local/remote selector, top/bottom loading selector,
• acquiring data (status). ATB/ATK selector, ATK pos. B/C preset selector, overfilling
• summarising partial or total data. bypass, open vapour recovery micro valve, closed vapour
• downloading delivery data. recovery micro valve, open block micro valve, closed
Remote control can be achieved by means of serial block micro valve, product 1/2/3 selector, Start/Stop ON-
dialogue with proprietary protocol or Mod-Bus RTU protocol. OFF, additivator unit A/B/C/D/E and F not ready, additive
pump signal, flow reduction 1/2, injection piston feedback
Valves add A/B, Gas extractor level (STOP), Gas extractor level
VEGA II can operate with the following types of valve: (LF)).
• Two stages
Two stages valve deliver the preset quantity by Slave function indications can be associated with each
controlling two solenoid valves (one for LF and one for digital output (up to 32, of which 16 power and 16 transistor):
HF). Flow rate values must be regulated beforehand, (not used, BF-NA-AC bottom, AF-NC bottom, BF-NA-AC top,
mechanically adjusting valves. VEGA II manages the AF-NC top, product 1/2/3 pump, product 1/2/3 selector,
initial low flow phase, the high flow phase and final low Alarm, block valve, vapour recovery, bottom vapour
flow phase, in such a way as to avoid “splash” recovery, top vapour recovery, bottom loading, top loading,
phenomena and foam from forming. The duration of impulse reset, additivator unit 1/2 enable, cleaning line,
these phases can be configured with the appropriate additive selection 1/2/3/4 additive selection, additive pump,
parameters. This valve allows you to use the automatic pump of additive A/B, injection valve/piston of additive A/B,
final adjustment function: if necessary, to obtain the preset active, status leak alarm)
exact quantity requested, preset is concluded with a The size impulses represent (volume, compensated volume,
sequence of short valve openings until the desired value mass) and a multiplication factor can be configured for each
is reached. pulse output (up to 4).
• Digital valve (Multistep)
This valve allows to regulate the flow rate during the
delivery besides to managing initial and final low flow
phases. Flow rate is adjusted to a fixed value by driving
two solenoid valves (one NO and one NC) in such a way
as to regulate the position of the valve membrane.
With this type of valve VEGA II can manage one default
high flow rate and two separate lower high-flow rates,
triggered by signals from two digital inputs. As alternatives
the high flow-rate can be set by serial line message.

ISOIL IMPIANTI S.p.A. - 24061 Albano S. Alessandro (BG) - Italy


tel : +39.02.91988.5 fax: +39.02.66012457
web: www.isoilmeter.com e-mail: sales@isoil-impianti.it Pag. 3/3
DS/VE/0016/EN -05/13
Configuring analog 4÷20 mA inputs • MRD Metrical Recording Device (MID approved)
The two 4÷20mA inputs can be configured to: The MRD is a device designed to store the delivery data
• receive the actual product’s density. It’s possible to select collected by serial line from several VEGA II (up to 64).
between two types of data represented in input: density MRD is suitable to replace a printer system with a mass
at Tb (base temperature) and density at Tamb memory recording system.
(environment temperature)
• receive the alpha cubic expansion coefficient Others ISOIL linkable devices:
• receive alcoholic strength value • LFD-06
Six digits Large Figure Display for remote data indication.
Configuring analog 4÷20 mA outputs • RF-ID Badge reader
The two 4÷20mA outputs can be configured to: Entry level RF-ID LF badge reader for operator
• send the actual or average product’s temperature identification.
• send the actual or average product’s flow-rate
• drive analog valves

Additive functions
VEGA II manages an in-line additive system as following:
• by using integrated additivation function (optional)
By managing directly two hydraulic of two metered or
piston additivators. VEGA II commands directly the
pump and the injection electro-valves or the piston. All
the parameter are set in VEGA II.
• by connecting through a serial line RS485 with ISOIL
FlexiMix device.
Can be managed up to six FlexiMix, each of which can
inject up to six additives. Totally can be managed up to six
additives.
In this case, VEGA II is able to:
o establish if additives are required or not,
o select the additive and the percentage,
o receive the quantity injected by FlexiMix,
o receive an alarm, to take diagnostic checks to
decide if the delivery should be continued or not.
• by connecting to “intelligent” additive devices,
generally equipped with electronics that receive
impulses representing the quantity and control a
hydraulic circuit with a dosing valve, piston or pump, to
supply quantities according to desired percentages.
VEGA II allows you to control two separate devices with
a maximum of four additives each using the following
digital signals:
o n° 2 D/O to select the device
o n° 4 D/O to select the additive
o n° 2 D/I to acquire alarms
Combining the different functionally mode it’s possible to
manage up to 6 additives simultaneously.

Printing reports.
VEGA II is able to produce reports that can be configured
with a set of specific parameters through different serial
protocols.
The ISOIL printing systems managed are:
• 80 columns serial printers:
o ST500A (RS232 max. distance 50 m)
o ST500B (RS422 max. distance 1000 m)
• Tickets serial printers:
o ST100B - Epson TM-U295 (RS232 max. distance 50 m)
o ST100C - Epson TM-U295 (RS422 max. distance 1000 m)
• SPD-02
This system allows up to a maximum of 32 VEGA II for
each of the RS422/RS485 serial lines it is equipped with.
The SPD-02 collects the data from each VEGA II and
prints on 80 columns printer.
SPD-02 can be ordered in a cold back-up version.
• ST500-M (MID approved)
This system allows up to a maximum of 16 VEGA II to be
connected in multi-point by RS422 or RS485 serial line. The
ST500-M collects the data from each VEGA II and prints
them on a 80 columns printer. Data frame is checked by
CRC16.

ISOIL IMPIANTI S.p.A. - 24061 Albano S. Alessandro (BG) - Italy


tel : +39.02.91988.5 fax: +39.02.66012457
web: www.isoilmeter.com e-mail: sales@isoil-impianti.it Pag. 4/4
DS/VE/0016/EN -05/13
TECHNICAL SPECIFICATIONS
Main power supply • 115/230 Vac (-15 /+10%), 50÷60Hz 40W max (VEGA II versions XXX5-XXXX)
• 24 Vdc (-15 /+10%) 40W max (VEGA II versions XXX7-XXXX)
Power supply for internal heating • 115/230 Vac (-15/+10%), 50÷60Hz 40W max (VEGA II versions XXX5-XXXX)
device • 24 Vdc (-15 /+10%) 40W max (VEGA II versions XXX7-XXXX)
Flow impulses input n° 1 input two channels phased of 90° ± 30°, fmax 5kHz
• NPN open collector
• Square wave inputs: V(High) = 4 Vdcmin ÷ 24 Vdcmax; V(Low) = 1,3 Vdc max
• proximity Namur
Power supply for pulse emitter • +5 Vdc 100 mA
• +15 Vdc 100 mA
Digital inputs n°16, powered by VEGA II (+15 Vdc)
or by external power supply V(Low)=1,5 Vdcmax V(High)=10÷30 Vdc;
Digital outputs n°8 current source powered by external power supply (5 ÷ 30 Vdc) Imax=0,5 A each
Digital impulses outputs n°4 current source powered by VEGA II (+15 Vdc) or by external power supply (5÷30
Vdc) Imax=0,3 A maximum for all outputs.
Digital power outputs n° 8 of witch:
• n° 4 mechanical relays (for all versions)
• n° 4 Vac solid state relays for versions powered by Vac voltage
• n° 4 Vdc solid state relays for versions powered by Vdc voltage
Characteristics for mechanical relay Characteristics for Vac solid state relay Characteristics for Vdc solid state relay
• AC Load: max 250 Vac • Operating voltage range: 60÷260Vac • Operating Voltage Range 5÷30 Vdc
• DC Load: max 125 Vdc (50÷60Hz) • Max Load Current: 2 A
• min switching load: 100mA, 5V • Load Current Range: 1 A • Max.Off-State Leakage @ Rated Voltage 200
• Max Off-State Leakage @ Rated µAdc 100 µAdc
Current: 2 mA • Max. On-State Voltage Drop @ Rated Current
• Max On-State Voltage Drop @ Rated 1.5 Vdc 0.4 Vdc
Current: 1,5 Vpk
• Minimum load current: 50 mA
Temperature inputs (optional) Use temperature input from a platinum RDT type Pt100 Class A IEC751, DIN 43760
(0,00385Ω/°C.).
Analog inputs 4÷20 mA (optional) n° 2 two wires 4÷20 mA. The resolution of the inputs is 16 bits (65.536 points).
Analog outputs 4÷20 mA (optional) n° 2 two wires 4÷20 mA. The resolution of the outputs is 12 bits (4096 points).
Serial communication lines • n° 2 lines RS485 two wires switchable as RS232 (RX, TX, COM)
• n° 1 lines RS422/485 four wires
• n° 1 RS232 (RX, TX, COM)
Internal battery Battery pack made by 10 primary cells 1,2V Ni Mh
Display Graphic Liquid Crystal Display (LCD) 240x128 pixel; white LED backlight.
-25 ÷ +55°C (-13 ÷ +131°F)
Operating temperature Note: The minimum temperature can be obtained only if the internal heating device
is powered.
Storage temperature -40 ÷ +65°C (-40÷149°F)
Relative humidity 5÷95 % with condensation
Ex environment according to ATEX II 2 G Ex d IIB T6 Gb Approval INERIS 00ATEX0025
Weatherproof IP66 Approval INERIS 00ATEX0025
Housing material Aluminium casting
Dimensions See drawing
Weight 20 kg approx.
Fitting • On the meter by means of N.4 M6 screws on holes Ø168,3 (compatible with
VEEDER ROOT™ mech. Counters)
• Remote by means of dedicated support swivelling that can be directed and
locked in the right position
Cable entries n° 2 holes 1” NPT + n° 4 holes 3/4”NPT
Push-buttons n° 19 solid state (10 alphanumeric + 9 function Keys)

Inputs and outputs on optional DIGITAL I/O BOARDs “SES X”


Digital inputs n°16, powered by VEGA II (+24Vdc)
or by external power supply V(Low)=1,5 Vdcmax V(High)=10÷30 Vdc;
Digital outputs n°8 current source powered by external power supply (5÷30 Vdc) Imax=0,5 A each
Power outputs • SES 1 = n. 4 Vac SOLID STATE RELAYS + n. 4 MECHANICAL RELAYS
• SES 2 = n. 4 Vdc SOLID STATE RELAYS + n. 4 MECHANICAL RELAYS
• SES 3 = n. 8 MECHANICAL RELAYS
• SES 4 = n. 8 Vac SOLID STATE RELAYS
• SES 5 = n. 8 Vdc SOLID STATE RELAYS

ISOIL IMPIANTI S.p.A. - 24061 Albano S. Alessandro (BG) - Italy


tel : +39.02.91988.5 fax: +39.02.66012457
web: www.isoilmeter.com e-mail: sales@isoil-impianti.it Pag. 5/5
DS/VE/0016/EN -05/13
VERSIONS OF FLOW COMPUTER “VEGA II ” X 2 9 X - X X X X

TOTALIZER + PRESET 3
TOTALIZER + PRESET+ TEMPERATURE COMPENSATION 4

WITHOUT INTERNAL PULSES EMITTER 2

ONE METER 9
BLENDING 4

POWER SUPPLY 115/230 Vac 5


POWER SUPPLY 24 Vdc 7

WITHOUT OPTIONAL DIGITAL I/O BOARD 0


SES 1 -16 INPUTS + 4 Vac SOLID STATE RELAYS + 4 MECHANICAL RELAYS + 8 DIGITAL OUTPUTS 1
SES 2 -16 INPUTS + 4 Vdc SOLID STATE RELAYS + 4 MECHANICAL RELAYS + 8 DIGITAL OUTPUTS 2
SES 3 - 16 INPUTS + 8 MECHANICAL RELAYS + 8 DIGITAL OUTPUTS 3
SES 4 - 16 INPUTS + 8 Vac SOLID STATE RELAYS + 8 DIGITAL OUTPUTS 4
SES 5 - 16 INPUTS + 8 Vdc SOLID STATE RELAYS + 8 DIGITAL OUTPUTS 5

WITHOUT SERIAL LINE n°4 (RS232) N


WITH SERIAL LINE n°4 (RS232) 1

WITHOUT I/O 4÷20 mA 0


WITH TWO INPUTS AND TWO OUTPUTS 4÷20 mA 1

WITHOUT INTEGRATED ADDITIVATION 0


WITH INTEGRATED ADDITIVATION (two additives) 1

ISOIL IMPIANTI S.p.A. - 24061 Albano S. Alessandro (BG) - Italy


tel : +39.02.91988.5 fax: +39.02.66012457
web: www.isoilmeter.com e-mail: sales@isoil-impianti.it
DS/VE/0016/EN -05/13 Pag. 6/6