Professional Documents
Culture Documents
Polyolefin Pipe Inuslation - Aerofoam
Polyolefin Pipe Inuslation - Aerofoam
TELEPHONE : 04 – 8848414
FAX : 04 – 8848434
WEBSITE : www.rhira.com
EMAIL : enquiry@rhira.com
CONTACT : MOUSTAFA/TOMASZ
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
Index
1. Product catalogue
2. Technical Data Sheet
3. Company Profile
4. Compliance statement
5. Test reports & Test Certificates
6. Technical bulletins
7. Third party certificates
8. Installation guide
9. Project reference list
10. Previous approvals
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
1. PRODUCT CATALOGUE
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
BROCHURE_AEROFOAM_XLPE_UAE_13APRIL21
2. TECHNICAL DATA SHEET
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
TECHNICAL DATA SHEET FOR
AEROFOAM XLPE
Description: Aerofoam XLPE is a cross linked closed cell polyolefin foam. Sheets & tubes are designed
for thermal insulation and protection against water vapor condensation. Designed for indoor and outdoor
application, however outdoor application needs additional cladding against UV radiation. Mostly used as
thermal insulation for pipes, tanks, air ducts and valves. It is manufactured in tubular shape or as plain
sheet or sheet with self adhesive backing. Sheets and tubes come with integrated aluminum foil finishing.
Water Vapor Permeance 0.00 perms - inch as per ASTM E96 standard
Water Absorption 0.05 kg/m2 as per BS EN 12087 standard
Reaction to Fire FSI <25 and SDI <50 as per ASTM E84
www.aerofoam.ae
TECHNICAL DATA SHEET FOR
AEROFOAM XLPE
Note 1. :
Aerofoam XLPE Sheets and tubes available with
- aluminium foil for indoor applications - different colors of foil available upon request
- N Clad foil for indoor and outdoor applications
Note 2. :
It is recommended to use AERO-FITTINGS - tees, elbows and y-branches pre-farbicated
by Manufacturer - to assure highest precision of installation.
TDS_AEROFOAM_XLPE_UAE_25Mar2021
3. COMPANY PROFILE
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
® ®
1200
‘Hira Industries’ is dedicated to provide customers ‘Hira Industries’ aim’s to be a Global Leader in
in the Construction Sector with products of the niche products in building product industry. We
highest quality, by developing a successful aim to be the Market Leaders in the segments and
partnership with them, exceeding their expectations the regions we choose to compete in.
and gaining their trust through outstanding
performance by every member of our team. We
provide work environments where our employees
can meet their potential and thrive in an atmosphere
of professionalism. Our aim is to become the
“Employer of Choice” within the Building Product
HVAC Acessories
Industry.
thermal
Air Ducts
Used for hot, chilled water pipes and air conditioning applications with
minimal cost of installation.
Automobile industries
Furniture packaging
Optical equipments
REFLECTIVE INSULATION
AeroReflect range is a thermal reflective insulation product which
prevents heat transfer by thermal radiations.
spaces.
www.hirawalraven.com
Diamond Tapes, the Adhesive Tapes Division of Hira
Legal Type Limited Liability Company)LLC( ذات مسئولية محدودة الشكل القانونى
Expiry Date 19/08/2021 تاريخ النتهاء Issue Date 20/08/2002 تاريخ الصدار
D&B D-U-N-S ® 561246349 الرقم العالمي Main License No. 536867 رقم الرخصة الم
No.
Register No. 60238 رقم السجل التجارى DCCI No. 72664 عضوية الغرفة
Remarks / الملحظات
Print Date 19/07/2020 12:32 تاريخ الطباعة Receipt No. 13590990 رقم اليصال
.اتصالت) للحصول على اذن الدفع/ (دو6969 أرسل رقم الرخصة إلى،يمكنك الن تجديد رخصتك التجارية من خلل الرسائل النصية القصيرة
Now you can renew your trade license by sending a text message )SMS(. Send your trade license number to 6969
)Du/ Etisalat( to receive payment voucher.
www.dubaided.gov.ae لمراجعة صحة البيانات الواردة في الرخصة برجاء زيارة الموقع. وثيقة إلكترونية معتمدة وصادرة بدون توقيع من دائرة التنمية القتصادية
Approved electronic document issued without signature by the Department of Economic Development. To verify the
license kindly visit www.dubaided.gov.ae
()*+,$(-
!"#$%! &'
%! &'$12"!#'$$3$$(-.$4)*5,$
%! &'$67 $89:;<= (-.$/0
$%&'()*&+
'(,-()./0(*1(2*' (>?.$/.
@"&A$6" 345678(8934($:;:;<0
$=;=;-;20(*1(2*' B*+,.$/C.
D"E$6" 345678(8934($:;:;<0
%! &'$R`'$$3$a.
.$
Yc"$3$b. _#$3$(5. 6"2!&"#!2A$3$()G+. 6"$3$/C. $673b-?.$/0
%! &'$d 2!e!2!'$$3$$()*+,.$(-.$*?G$$
fAIAVCE(aVCB>IU )'"d(%"e[
dEE''$3$$g.HG.
ic&$6 PROgSgTSRQOOK gH5)h, i7j7$VP KJNRT )f$kHG
o"P$6 PROgSgTSRQMMK n>*[ i" #$J1 J (I.$/0
R`!#$6 PROgKJgSKQNSJJ l,T$a,*m )h(g(%*(g((Y'X\(''(Y'X\('(ij'(k'
O"!#$3$SGH,>C.$)f.
_"p'$3$q*rsT.
vvv;BwDC>BAB;UG|;CA(th&'(%"*Z(~"e\()n(u(%&(,"W"*\()()e';()*"[h()*'W[(%+(Y'(t*h&[(Y&\(%"&(%'['()*W&[.m()q*&(
4HHVG|AB(AEAx@VGI>x(BGxw?AI@(>yywAB(v>@}Gw@(y>UIC@wVA(DF(@}A({AHCV@?AI@(G(6xGIG?>x({A|AEGH?AI@;( aG(|AV>F(@}A(
E>xAIyA(>IBEF(|>y>@(vvv;BwDC>BAB;UG|;CA
4. COMPLIANCE STATEMENT
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
Product Specification Compliance Statement
PROJECT : REPLACEMENT OF CHILLED WATER
PIPES AND FCU/AHU VALVE PACKAGES
IN JA JABEL ALI BEACH HOTEL
MAIN CONTRACTOR : BK GULF FACILITIES MANAGEMENT LLC
HVAC CONTRACTOR : VERISTAR BUILDING MAINTENANCE LLC
Compliance Statement
S.N. SPECIFICATION PROPOSAL REMARKS
Chilled Water Pipe Insulation Proposed AEROFOAM XLPE
Cross linked closed cell polyolefin foam
composite, heat laminated to aluminium foil
face.
CFC, HCFC free and has zero ozone depleting
potential.
Temperature Range:
-80°C to + 105°C.DIN EN 14706
Thermal Conductivity :
0.035 W/m·K at 24°C as per ASTM C518 Comply
Fire Rating:
Class 1 BS 476 Part 7
Class 0 BS 476 Part 6.
ASTM E 84
Resistance to Corrosion: ASTM B117
Resistance to Fungi: ASTM G21
Resistance to Bacteria: ISO 22196
Thickness:
25mm (For Pipe Size below 4”)
Prepared by :NPY
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
5. TEST REPORTS & TEST CERTIFICATES
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
Test Reports & Test Certificates Index
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
1. THERMAL CONDUCTIVITY – ASTM C 518
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
Dubai Central Laboratory
Construction Materials Laboratory Section - Structural Unit
TEST REPORT
THERMAL TRANSMISSION PROPERTIES BY HEAT FLOW METER (THERMAL COND)
TEST RESULTS
PARAMETERS RESULTS
SAMPLE TYPE AEROFOAM XLPE / FLEXICELL XLPE
SUPPORT / FACING ONE SIDE ALUMINIUM FOIL AND OTHER SIDE ADHESIVE BACKING
NOM. THICKNESS (mm) : 20
NOM. DENSITY (kg/m3) : 45
SPECIFICATION LIMIT NG
TEST METHOD VARIATION NIL
PARAMETERS RESULTS
MEASURED THICKNESS (L) (mm) 20.075
MEASURED DENSITY (kg/m3) 36.31
MEAN TEMPERATURE ACHIEVED 23.73
(deg C)
HEAT FLUX (E) W/m2.K. 5255
THERMAL CONDUCTIVITY, W/(m K) 0.0358
THERMAL CONDUCTIVITY, Btu-in 0.2482
/h.square ft.degF
THERMAL RESISTANCE, (Square m K) 0.5608
/W
THERMAL RESISTANCE, ft square / 3.1849
Btu
AVERAGE TEMPERATURE 1003.28
GRADIENT (K/m)
WEIGHT DIFFERENCE (%) 0.0900
TEST DURATION ( h:mm:ss ) 00:40:01
Remarks: THIS REPORT REPRESENTS THE SUBMITTED SAMPLES ONLY. ,Uncertainty of measurement for thermal conductivity
0.0010 W/m·K @ 95% confidence level, k factor 2 Abridged ASTM C 518 Test Report.
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
3. FLAME SPREAD INDEX & SMOKE DEVELOPED INDEX – ASTM E 84
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
HIRA INDUSTRIES
LLC
FIRE TEST REPORT
SCOPE OF WORK
ASTM E84 TESTING ON AEROFOAM XLPE/FLEXICELL XLPE SA WITH ALUMINUM FOIL –
30MM
REPORT NUMBER
104400150SAT-001
TEST DATE
7/30/20
ISSUE DATE
7/30/20
PAGES
09
Telephone: 210-635-8100
Facsimile: 210-635-8101
www.intertek.com/building
TEST REPORT FOR HIRA INDUSTRIES LLC
Report No.: 104400150SAT-001
Date: 7/30/20
REPORT ISSUED TO
Hira Industries LLC
Al Ghail Industrial Area
PO Box 9013, Ras Al Khaimah
UAE
SECTION 1
SCOPE
Intertek Building & Construction (B&C) was contracted by Hira Industries LLC, Al Ghail Industrial
Area, PO Box 9013, Ras Al Khaimah, UAE, to evaluate the flame spread and smoke developed
properties of Aerofoam XLPE/Flexicell XLPE SA with Aluminum Foil – 30mm. Testing was
conducted at the Intertek B&C test facility in Elmendorf, Texas. Results obtained are tested
values and were secured by using the designated test method(s). A summary of test results and
the complete graphical test data is reported herein.
This report does not constitute performance certification of this product nor an opinion or
endorsement by this laboratory. Intertek B&C will service this report for the entire test record
retention period. The test record retention period ends four years after the test date. Test
records, such as detailed drawings, datasheets, representative samples of test specimens, or
other pertinent project documentation, will be retained for the entire test record retention
period.
SECTION 2
SUMMARY OF TEST RESULTS
SIGNATURE: SIGNATURE:
DATE: 7/30/20 DATE: 7/31/20
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.
Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any
party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the
Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in
writing by Intertek. The observations and test results in this report are relevant only to the sample(s) tested. This report by itself
does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Telephone: 210-635-8100
Facsimile: 210-635-8101
www.intertek.com/building
TEST REPORT FOR HIRA INDUSTRIES LLC
Report No.: 104400150SAT-001
Date: 7/30/20
SECTION 3
TEST METHOD
SECTION 4
MATERIAL SOURCE/INSTALLATION
The test specimen was submitted to Intertek directly from the client. Samples were not
independently selected for testing. Intertek has not verified the composition, manufacturing
techniques or quality assurance procedures. The specimen, identified as Aerofoam
XLPE/Flexicell XLPE SA with Aluminum Foil – 30mm, was received in good order at the
Evaluation Center on 7/24/20 and given identification number SAT2007241420-001.
SECTION 5
LIST OF OBSERVERS
NAME COMPANY
Joseph Martinez Intertek B&C
SECTION 6
TEST PROCEDURE
This report describes the results of testing conducted in accordance with ASTM E84-20;
Standard Test Method for Surface Burning Characteristics of Building Materials. The test method
is for comparative surface burning behavior of building materials by determining a flame spread
index (FSI) and a smoke developed index (SDI). This test is generally applicable to exposed
surfaces, such as finish materials for ceilings or walls, provided that the material or assembly of
materials, by its own structural quality or the manner in which it is tested and intended for use,
is capable of supporting itself in position or being supported during the test period.
“The use of supporting materials on the underside of the test specimen has the
ability to lower the flame spread index from those which might be obtained if
the specimen could be tested without such support. These test results do not
necessarily relate to indices obtained by testing materials without such support.
Testing of materials that melt, drip, or delaminate to such a degree that the
continuity of the flame front is destroyed, results in low flame spread indices
Telephone: 210-635-8100
Facsimile: 210-635-8101
www.intertek.com/building
TEST REPORT FOR HIRA INDUSTRIES LLC
Report No.: 104400150SAT-001
Date: 7/30/20
that do not relate directly to indices obtained by testing materials that remain in
place.” – ASTM E84-20 Sections 1.4 – 1.5
The purpose of the method is to determine the relative burning behaviour of the material by
observing the flame spread along the specimen. Flame spread and smoke developed index are
reported. However, there is not necessarily a relationship between these two measurements.
SECTION 6 (Continued)
TEST PROCEDURE
It is the expressed intent of the test method to provide only comparative measurements of
surface flame spread and smoke density of the tested material against measurements for select
grade red oak flooring and fiber-cement board when tested under specific fire exposure
conditions. The test method exposes a nominal 24-ft (7.32-m) long by 20-in. (508-mm) wide test
specimen to a controlled air flow and flaming fire exposure adjusted to produce a specific flame
spread distance vs time calibration using select grade red oak flooring.
The test method does not provide information regarding heat transmission through the tested
surface, the effect of aggravated flame spread behavior resulting from the proximity of
combustible walls and ceilings, or the classification or definition of materials as noncombustible
using flame spread index alone.
This standard should be used to measure and describe the properties of materials, products, or
assemblies in response to heat and flame under controlled laboratory conditions and should
not be used to describe or appraise the fire hazard or fire risk of materials, products, or
assemblies under actual fire conditions. However, results of this test may be used as elements
of a fire risk assessment which takes into account all of the factors which are pertinent to an
assessment of the fire hazard of a particular end use.
Telephone: 210-635-8100
Facsimile: 210-635-8101
www.intertek.com/building
TEST REPORT FOR HIRA INDUSTRIES LLC
Report No.: 104400150SAT-001
Date: 7/30/20
SECTION 7
TEST SPECIMEN DESCRIPTION
Telephone: 210-635-8100
Facsimile: 210-635-8101
www.intertek.com/building
TEST REPORT FOR HIRA INDUSTRIES LLC
Report No.: 104400150SAT-001
Date: 7/30/20
SECTION 8
TEST RESULTS
TEST RESULTS
Test Date 7/30/20
Test Operator Joseph Martinez
Flame Spread Index (FSI) 20
Smoke Developed Index (SDI) 40
TEST DATA
FSI (unrounded) 18.6
SDI (unrounded) 41.07
FS * Time Area (Ft * Min) 36.2
Smoke Area (% * Min) 34.5
Total Fuel Burned (Cubic Ft.) 41.84
Max Flame Front Advance (Ft.) 3.9
Time to Max Flame Front (sec) 75
Max Temp At Exposed T/C (°F) 586
Time To Max Temp (sec) 596
TEST OBSERVATIONS
Ignition Time 0:15
Cracking Observed 0:15
Flaking Observed 0:32
After Flame 0:31
Observations After the Test:
0 – 4 ft. The foil was consumed. The foam was melted.
4 – 9 ft. The foil was heavily charred.
9 – 24 ft. The foil was discolored.
Telephone: 210-635-8100
Facsimile: 210-635-8101
www.intertek.com/building
TEST REPORT FOR HIRA INDUSTRIES LLC
Report No.: 104400150SAT-001
Date: 7/30/20
SECTION 8 (Continued)
TEST RESULTS
COMMENTARY ON CLASSIFICATION
Neither ASTM E84 nor UL 723 include classification criteria for the results obtained from testing.
The International Building Code® (IBC), NFPA 101: Life Safety Code® (NFPA 101), and NFPA 5000:
Building Construction and Safety Code® (NFPA 5000) all describe a set of classification criteria
required for interior wall and ceiling finish materials based on Flame Spread Index and Smoke
Developed Index when tested in accordance with ASTM E84 or UL 723. The classification criteria
for all three model codes is the same:
A 0-25 0-450
B 26-75 0-450
C 76-200 0-450
Note that classification under this scheme for interior wall and ceiling finishes does not strictly
apply to all products or materials tested in accordance with ASTM E84 or UL 723 because not all
products or materials are recommended or suitable for use as interior wall or ceiling finish
materials in buildings, regardless of the surface burning characteristics. Consult with the
product manufacturer and the local authority having jurisdiction (AHJ) regarding specific
applications of a given product or material.
Telephone: 210-635-8100
Facsimile: 210-635-8101
www.intertek.com/building
TEST REPORT FOR HIRA INDUSTRIES LLC
Report No.: 104400150SAT-001
Date: 7/30/20
SECTION 10
GRAPHS
Telephone: 210-635-8100
Facsimile: 210-635-8101
www.intertek.com/building
TEST REPORT FOR HIRA INDUSTRIES LLC
Report No.: 104400150SAT-001
Date: 7/30/20
SECTION 11
REVISION LOG
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
5. WATER ABSORPTION – BS 12087
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
6. WATER VAPOR TRANSMISSION – ASTM E 96
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
Dubai Central Laboratory
Construction Materials Laboratory Section - Structural Unit
TEST REPORT
WATER VAPOR TRANSMISSION OF INSULATION MATERIALS
TEST RESULTS
PARAMETERS RESULTS
SAMPLE TYPE Aerofoam XLPE/Flexicell XLPE
SUPPORT / FACING ONE SIDE ALUMINIUM FOIL AND OTHER SIDE ADHESIVE BACKING
NOM. THICKNESS (mm) : 12
NOM. DENSITY (kg/cubic m) : 25
SPECIMEN NO. 1 2 3
SPECIMEN MEASURED THICKNESS 12.0 12.6 12.4
(mm)
SPECIMEN MEASURED DENSITY 45.1 44.0 44.2
(kg/cubic m)
WATER VAPOR TRANSMISSION (g/h 0.0 0.0 0.0
m2) - *METRIC UNIT
PERMEANCE (g/Pa. s. m2) - *METRIC 0.0 0.0 0.0
UNIT
WATER VAPOR TRANSMISSION 0.0 0.0 0.0
(grains/h. ft2) - *INCH-POUND UNIT
PERMEANCE (perms) - *INCH-POUND 0.0 0.0 0.0
UNIT
AVG. WATER VAPOR 0.00
TRANSMISSION (grains/h. ft2) - *INCH-
POUND UNIT
AVG. PERMEANCE (perms) - *INCH- 0.00
POUND UNIT
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
8. RESISTANCE TO FUNGI – ASTM G 21
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
9. VOC EMISSION – CDPH V1.2.2017
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
10. ODP & GWP
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
BUREAU
VERITAS
TEST REPORT
LAB ANALYSIS OF AEROFOAM XLPE
INSULATION PRODUCTS
. Result
Sr. No Test Done
Remark: -
AUTHORISED SIGNATORY
.~,
FOR BUREAU VERITAS S.A DUBAI
We Bureau Veritas certify that the above tests were carried out in an accredited lab, in accordance with official Methods of and witnessed
by Bureau Veritas.
11. FORMALDEHYDE EMISSION – EN 717-1
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
6. TECHNICAL BULLETINS
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
AEROFOAM® XLPE
Cross-Linked Closed-Cell Polyolefin Thermal Insulation Foam
Product Compliance
Al Sa’fat Dubai Green Building Regulations
For Pipe and Duct Insulation
1. Introduction
Green building is the practice of creating environment that increase efficiency use of different energy sources as well as
water and other materials. The concept focuses on reducing impacts of the building on environment and human health
by improved construction, design operation and maintenance.
UAE started implementing Green Building Regulations in 2007 to assure highest sustainability practices focusing on
energy, water, carbon emission and public health in all Emirates.
Currently it is mandatory for all new buildings to follow Al Sa’fat – Dubai Green building System Regulations and to obtain
minimum Silver Sa’fa grade.
AEROFOAM® XLPE is manufactured in line with local requirements and regulations. To assure Clients, Consultants and
Contractors about its Green Building compliance, AEROFOAM® XLPE is certified by Dubai Central Laboratory and
approved by UAE Civil Defense.
2. Al Sa’fat – Dubai Green Building Regulations for Pipe and Duct Insulation
However, there are several chapters focusing on different type of materials and requirements that must be followed to
comply with Al Sa’fat – Dubai Green Building Regulations.
In case of Thermal Insulation materials - Pipe and Duct Insulation, Consultants should refer to Section Seven of Al Sa’fat
Dubai Green Building Regulations, to assure that products comply with the system.
Figure 1 presents requirements for Thermal and Acoustical Insulation materials covered in Section Seven, Chapter 1, of
Al Sa’fat Dubai Green Building Regulations.
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
Figure1: Section Seven, Chapter 1, of Al Sa’fat Dubai Green Building Regulations
Above mentioned requirements are mandatory for all Thermal and Acoustical Insulation Materials. Each product that is
going to be installed in new buildings in UAE shall fully comply with all above mentioned points.
3. Al Sa’fat – Dubai Green Building Regulations Compliance for AEROFOAM® XLPE Cross-Linked Closed-Cell
Polyolefin Thermal Insulation Foam
Hira Industries obtained mandatory DCL Certificate for AEROFOAM ® XLPE Cross-Linked Closed-Cell Polyolefin
Thermal Insulation Foam to assure Clients, Consultant and Contractors about product compliance with the mandatory
regulations.
However, DCL Certification is only one point out of full Section 7 that shall be followed during approval stage by
Consultants.
Tables below present compliance statement covering all points related to Thermal Insulation Materials mentioned in
Section 7, Al Sa’fat Dubai Green Building Regulations.
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
Statement Compliance of AEROFOAM® XLPE
701.01 Thermal and Acoustical Insulation materials
1. Be manufactured without the use of AEROFOAM® XLPE is manufactured free of CFC’s. Does not
Chlorofluorocarbons (CFC’s). contain any material/substance that contribute to Ozone
Depletion Potential nor Global Warming Potential certified by
Bureau Veritas.
2. Be non-toxic and not release toxic fumes during AEROFOAM® XLPE has no content of toxic components and can
combustion. be in direct touch with humans and animals, as well has been
tested in accordance with EN-45545 to determinate the toxicity of
the released fumes during combustion achieving the lower values
than required by the regulations.
3. Have 0.05 parts per million (ppm) or less of AEROFOAM® XLPE has concentration of Formaldehyde lower
added formaldehyde. than 0.0016 ppm after 10 days in accordance with EN 717-1.
Certified by Bureau Veritas.
4. Have a Threshold Limit Value (TLV) of 0.1 or less AEROFOAM® XLPE has been tested in accordance with CDPH
of Individual Volatile Organic Compounds V1.2 to determine the content and Emission of VOC:
5. Be fire resistant in accordance with the AEROFOAM® XLPE is approved by Dubai Civil Defense.
requirements of Dubai Civil Defense
7. Achieve all the requirements of the approved AEROFOAM® meets all the requirements.
specifications by Dubai Municipality.
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
Statement Compliance of AEROFOAM® XLPE
701.03 Asbestos Containing Materials.
For all new buildings and for the maintenance, AEROFOAM® XLPE is manufactured with no content of
addition or alteration of existing buildings, asbestos in compliance to local and international regulations to
materials containing asbestos must not be used. avoid the use of asbestos in construction materials.
For all new buildings and for the maintenance, AEROFOAM® XLPE is manufactured with no content of Lead or
addition or alteration of existing buildings, paints, Heavy Metals.
or other materials, containing lead or other heavy
metals with percentage more than the approved
specifications by Dubai Municipality must not be
used unless the metal is encapsulated in a system
such as a photovoltaic cell.
All paints and materials containing lead or other
heavy metals must be accredited /certified from
Dubai Central Lab or any source approved by Dubai
Municipality.
For all new buildings, building materials available AERFOAM® XLPE manufacturing plant is in Al Ghail Industrial
regionally must comprise at least five percent (5%) Area, Ras al Khaimah, UAE.
of the total volume of materials used in the
construction of the building.
4. Conclusions
Presented data proves that AEROFOAM ® XLPE Cross-Linked Closed-Cell Polyolefin Thermal Insulation Foam fully
comply with Al Sa’fat Dubai Green Building Regulations.
AEROFOAM® XLPE is manufactured without the use of Chlorofluorocarbons (CFC’s), is non-toxic, has low Volatile
Organic Compounds emission, is certified by Dubai Central Lab and approved by Dubai Civil Defense.
Moreover, installation of AEROFOAM ® XLPE supports Clients to obtain Silver, Golden and Platinum Sa’fa Grades for all
types of new buildings.
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
7. THIRD PARTY CERTIFICATES
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
CERTIFICATE OF PRODUCT CONFORMITY
Dubai Central Laboratory Department (DCLD) of Dubai Municipality
hereby attests that the product(s)
or / EN
for E G AM
GR
ENGR. MIN
AMINNA HMED
HM
MED
AHMEDED AAMIN
Director, Dubai Central Laboratory Department
Dubai Municipality
The attached Scope of Certification bearing the same Certificate Number forms an integral part of this Certificate.
This Certificate is an electronic document subject to the Terms and Conditions of the Product Certification System and shall not be reproduced except in full.
DM-DCLD-F-IC-2031 Rev 17
8. INSTALLATION GUIDE
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
AeroSound
AeroSound
4
5
4
5
412
13
5
4
5
AEROSOUND SL+ / SLM
INSTALLATION METHODOLOGY
AeroSound
SL+
AeroSound SL+
AEROSOUND ACOUSTIC DUCT LINER
INSTALLATION METHODOLOGY
AeroSound AeroSound
LN and LX
AeroSound
AeroSound
AeroCalc
422
5
Mullan Professional Building,
1121 E, Mullan Avenue Suite 204,
COEUR D’ ALENE, IDAHO 83814
9. PROJECT REFERENCE LIST
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
UAE, DUBAI
Project Al Badaa Resedential Al Satwa
Consultant Dewan Architects Engineers
MEP Contractor Al Kaitoob
Material Aerofoam XLPE Duct & Pipe
Project Neuro Spinal Hospital
Consultant Cubic
MEP Contractor GECO
Material Aerofoam XLPE Duct & Pipe
Project Construction of 133 Villas
Consultant Arif & Bintoak
MEP Contractor Al Andalous
Material Aerofoam XLPE tubes
Project 2575 Town Square Development
Consultant Al Gurg
MEP Contractor Shapoorji
Material Aerofoam XLPE Duct& Pipe
Project Al Jimi Mall Phase 4
Consultant ACG
MEP Contractor Tripoli
Material Aerofoam XLPE Duct
Project Staff Accomodation Al Warsan
Consultant BDPL
MEP Contractor Honest Hand
Material Aerofoam XLPE Duct& Pipe
Project Villa Nova Street of Dreams @ Dubailand
Consultant Arif & Bintoak
MEP Contractor Al Futtaim
Material Aerofoam XLPE Pipe
Project Souk warsan
Consultant AE7
MEP Contractor Alozone
Material TUBES: 25,000 meters ROLLS: 15,550 sqm
Project Shobha Hart Land villas
Consultant PNC
MEP Contractor Shobha
Material TUBES: 20,000 meters ROLLS: 10,550 sqm
Project Expo Centre Sharjah Extension
Consultant WSP
MEP Contractor AMBB
Material TUBES: 15,000 meters
Project Aster Hospital Plot no.: 316‐524
Consultant Arif and Bintoak
MEP Contractor Power Factor
Material TUBES: 5,000 meters; ROLLS: 5,550 sqm
Project Sofittel Hotel @ Palm Jumeriah
Consultant Mirk
MEP Contractor B.K. Gulf
Material TUBES: 135,000 meters; ROLLS: 55,000 sqm; SHEETS: 20,000 sqm
Project 2012 School Refurbishment Program, Al Hemma School
Consultant UPA
MEP Contractor Carawan Pioneer Electrical
Material TUBES: 1,000 meters; ROLLS: 2,500 sqm
Project B+G+5 University CampusS @ Dubai Academic City
Consultant Proleed Engineering
MEP Contractor Donrite Electromechanical Works
Material TUBES: 5,000 meters; ROLLS: 8,500 sqm
Project G+6 Storey Residential @ Al Warqa Dubai
Consultant Lacasa
MEP Contractor Arifco
Material TUBES: 3,000 meters; ROLLS: 8,000 sqm
Project Commercial & Residential
Consultant Arif and Bintoak
MEP Contractor Power Factor
Material TUBES: 5,000 meters; ROLLS: 8,000 sqm
Project Al Amal Hospital
Consultant HDP
MEP Contractor China State
Material TUBES: 15,000 meters; ROLLS: 35,000 sqm
Project Residentail Blocks ‐ City Walk Phase 1
Consultant Hyder
MEP Contractor Al Shafer General Contracting
Material TUBES: 20,500 meters; ROLLS: 25,550 sqm
Project 2012 School Refurbishment Program, Al Hemma School
Consultant UPA
MEP Contractor Carawan Pioneer Electrical
Material TUBES: 1,000 meters; ROLLS: 2,500 sqm
Project Expo Centre Sharjah Extension
Consultant WSP
MEP Contractor AMBB
Material TUBES: 15,000 meters
Project Novotel Hotel
Consultant Seeds Engineering Consultant
MEP Contractor B.K. Gulf
Material TUBES: 8,000 meters; ROLLS: 6,000 sqm; SHEETS: 5,000 sqm
Project G+21 Building at Al Rafaa ‐ Bur Dubai
Consultant NEB
MEP Contractor Al Shirawi Electromechanical Co.
Material TUBES: 9,800 meters; ROLLS: 15,000 sqm; SHEETS: 1,100 sqm
Project G+22 Coral International Hotel
Consultant BHNS ENG.
MEP Contractor Al Shirawi Electromechanical Co.
Material TUBES: 3,500 meters; ROLLS: 5,000 sqm; SHEETS: 500 sqm
Project B+G+M+HC Residential Building @ Al Karama
Consultant Design Center
MEP Contractor Al Shirawi Electromechanical Co.
Material TUBES: 5,500 meters; ROLLS: 5,000 sqm; SHEETS: 1,000 sqm
Project G+5 @ Academic City
Consultant Proleed
MEP Contractor Bin Lahej E/M
Material TUBES: 3,800 meters; ROLLS: 2400 sqm; SHEETS: 1,100 sqm
Project Al Bateen Tower
Consultant NEB
MEP Contractor Commodore
Material TUBES: 14,500 meters; SHEETS: 550 sqm
Project "W" HOTEL & RESIDENCES PALM JUMEIRAH DUBAI
Consultant LEAS CONSULATANT
MEP Contractor AL FUTTIM
Material TUBES:100,000 meters; ROLLS:40,000 sqm
Project Clover Tower
Consultant NEB
MEP Contractor Al Ittihad Electrical Co.
Material TUBES: 8,300 meters; ROLLS: 3,550 sqm
Project G+4 R'tl D'lpmt @ Muhaisanah
Consultant Bel‐Yoahah
MEP Contractor Powrfactor
Material ROLLS: 35,000 sqm; SHEETS: 8,000 sqm
Project G+10 @ Al Quasis
Consultant Development Consultancy
MEP Contractor Power Factor
Material ROLLS: 2,500 sqm; SHEETS: 850 sqm
Project DIP Polyclinic
Consultant A2Z Arch. Engg.
MEP Contractor Power Factor
Material TUBES: 1,000 meters; ROLLS: 500 sqm; SHEETS: 850 sqm
Project Sulthan Belshalth Hotel
Consultant Adwar Engineering consultant
MEP Contractor Power Factor
Material TUBES: 5,500 meters; ROLLS: 7,500 sqm
Project G+18 "The Corner" at Business Bay
Consultant Development Consult, Architects, Engineers & planners
MEP Contractor Aikah
Material SHEETS: 1,000 sqm
Project JBF Industries at RAK
Consultant Consistant Engineering
MEP Contractor Honest Hands
Material TUBES: 650 meters; ROLLS: 6,500 sqm
Project Rak Church
Consultant ‐
MEP Contractor Al Shafar United
Material TUBES: 1,050 meters; ROLLS: 8,500 sqm
Project G+14 at Tecom
Consultant Al Ajmi
MEP Contractor Naresco
Material ROLLS: 4,600 sqm
Project UAE Pavllion
Consultant GHD
MEP Contractor Penguin Engineering
Material ROLLS: 500 sqm
Project G+5 / G+6 at Liwan
Consultant NEB
MEP Contractor Pluto Electromechanical
Material TUBES: 2,000 meters; ROLLS: 5,000 sqm
Project G+1 @ Tecom
Consultant ‐
MEP Contractor Al Arabia Electromechanical
Material ROLLS: 1,100 sqm
Project MOBIS Warehouse at Jafza
Consultant Global Engineering
MEP Contractor Bridgeway
Material TUBES: 2,300 meters; ROLLS: 8,000 sqm; SHEETS: 650 sqm
Project Bay Central @ Marina
Consultant NEB
MEP Contractor Al Hamad Contracting Co.
Material ROLLS: 14,500 sqm
Project Al Muraqqabat hotel Development
Consultant Dimensions
MEP Contractor IEMSC
Material TUBES: 10,000 meters; ROLLS: 15,000 sqm
UAE, ABU DHABI
Project Al Ain Hospital
Consultant Obermeyer
MEP Contractor Advance National
Material XLPE TUBES: 58,900 mtr
Project Al Falah Health Care Center
Consultant Pioneer Engineering Consultant
MEP Contractor ARCO
Material XLPE TUBES: 10,700 mtr
Project National Dairy Plant
Consultant WME ‐ Consultant
MEP Contractor ALGECO ‐ AL AIN
Material XLPE TUBES ‐ 2,500 mtr ; ROLLS ‐ 7,520 sqmtr
Project Burjeel Royal Hospital
Consultant STH
MEP Contractor Alkaline Electromechanical
Material XLPE TUBES ‐ 415 mtr ; ROLLS ‐ 3,110 sqmtr
Project Al Tayer
Consultant APG
MEP Contractor Al Sabbah Electromechanical
Material XLPE TUBES ‐ 88,200 mtr ; ROLLS/SHT ‐ 15,172 sqmtr
Project 15 Quiranat Flowlines Iraq
Consultant British Petroleum
MEP Contractor China Petroleum
Material XLPE TUBES ‐ 96,876 mtr
Project Saadiyat Beach Apartments
Consultant Shanland Cox
MEP Contractor Envicon
Material XLPE SHEETS ‐ 6,000 sqmtr
Project Rixos Hotel
Consultant APG
MEP Contractor Two Power
Material XLPE TUBES ‐ 12,165 mtr ; SHEETS ‐ 1,000 sqmtr
Project Harbour Views
Consultant ATK
MEP Contractor Al Sabbah Electromechanical
Material XLPE TUBES ‐ 13,200 mtr
Project PGC
Consultant Al Salaam
MEP Contractor HK Advanced
Material XLPE TUBES ‐ 3,888 mtr ; SHEETS ‐ 5,720 sqmtr
Commercial Center at Abu Dhabi City
Project Commercial Center at Abu Dhabi City
Consultant Dimension Engineering
MEP Contractor Al Mezin
Material XLPE TUBES ‐ 3,025 mtr ; ROLLS/SHT ‐ 13,320 sqmtr
Project Serena Bela Casa
Consultant Dewan
MEP Contractor Verger Del Porte
Material XLPE TUBES ‐ 191,055 mtr
Project Fatima College
Consultant Mimar
MEP Contractor Tornado
Material XLPE ROLLS/SHT ‐ 3,238 sqmtr
Project NMC Hospital
Consultant STH
MEP Contractor Green Vision
Material TUBES: 13,000 meters; ROLLS: 53,000 sqm
Project Residential Villas‐Hamad, Nasar
Consultant IECC
MEP Contractor Al Qumra Gen. Transport
Material ROLLS: 2,500 sqm
Project VILLAS 2235,2236,2237 & 2238
Consultant Tameer Engineering Consultant
MEP Contractor Al Qumra Gen. Transport
Material ROLLS: 2,500 sqm
Project MOSQUE
Consultant Al Suweidi Engineering
MEP Contractor Al Qumra Gen. Transport
Material ROLLS: 2,500 sqm
Project Villa‐ Suha Saeed Ali
Consultant Aanan Saffarini
MEP Contractor Al Qumra Gen. Transport
Material ROLLS: 2,500 sqm
Project EPC Accomodation
Consultant ADNOC
MEP Contractor Asqalan Gen Contracting
Material TUBES
Project Baraka Accomodation
Consultant Takreer
MEP Contractor CIVILCO
Material TUBES: 4,500 meters; ROLLS: 21,000 sqm
Project Shamka Shoping Center
Consultant Herberger
MEP Contractor CIVILCO
Material TUBES: 4,500 meters; ROLLS: 21,000 sqm
Project Comm Bldg Habroush Suwidi
Consultant APG
MEP Contractor CIVILCO
Material TUBES: 4,500 meters; ROLLS: 21,000 sqm
Project Northern Car Park
Consultant ATKINS
MEP Contractor CIVILCO
Material TUBES: 4,500 meters; ROLLS: 21,000 sqm
Project Mushrif Park
Consultant MIRO
MEP Contractor ZENER
Material TUBES
Project Comm Bldg Rawadat Auh
Consultant APG
MEP Contractor ECOTHERM
Material TUBES: 5,500 meters; ROLLS: 6,000 sqm
Project Villa‐Khalifa Rashed
Consultant Reef Engineering Consultants
MEP Contractor Al Qumra Gen Transport
Material ROLLS: 2,500 sqm
Project Ahmed Mohammed Hilal Suroor Al Kaabi
Consultant Adnan Saffarini
MEP Contractor Al Qumra Gen Transport
Material ROLLS: 2,500 sqm
Project New Stores & Workshops
Consultant National Engineering Bearue
MEP Contractor Engineering Ways
Material ROLLS: 1,200 sqm
Project Villas‐ Hassan Ali
Consultant Bainoona Engineering Consultants
MEP Contractor Al Qumra Gen Transport
Material ROLLS: 2,500 sqm
Project Shahama Residence
Consultant Pioneer Engineering Consultants
MEP Contractor GHANOOT
Material ROLLS: 5,000 sqm
Project Al Mafraq Sschool
Consultant UPA
MEP Contractor ADVANCE PRO
Material TUBES: 3,983 meters; SHEETS: 480 sqm
Project Chemeweyyat & IPEC Tower
Consultant Hilal & Partners
MEP Contractor Electrocool Star
Material TUBES: 1,485 meters; SHEETS: 7,392 sqm
Project Universal Hospital
Consultant STH
MEP Contractor Emirates National
Material TUBES: 1,000 meters
Project Southern Sun Hotel
Consultant Derby Design
MEP Contractor China State Construcion
Material TUBES: 1,000 meters
Project Abu DhabiI Iconic Green House
Consultant Atlier Ten
MEP Contractor Al Ryum
Material ROLLS/SHEETS: 14,983 sqm
10. PREVIOUS APPROVALS
P.O.Box 50673, Dubai Investments Park 2. | www.rhira.com | E: enquiry@rhira.com | T: +971 4 8848 414
Duct thermal insulation is accepted based on media temp inside the
duct and given ambient condition for each area, the insulation
thickness shall be verified base on air side equipment approval in
relation with off coil temp.
Status :
Note:
1. Employer's no objection does not relieve either the Consultant or Contractor of their responsibilities under the Consultancy/contract Agreement.
2. Only Relevant Samples to be submitted for preliminary approval.
(Approval shall not relieve the Contractor of his liabilities under the Contract or constitute authorization of any change to Contract Documents)
Comments
Node Node Name Requester/Approvers Assigned Date Completion Date Action Comments if any
May 30/5/2020 11:11:00 30/5/2020 11:12:24 RAQ-RDJ161-SC-DPW-MS-034-01 - XLPE Duct & Pipe
1 Contractors/Consultants(PPMD) Request
Genayas(may.genayas) AM AM Insulation
ALMA G. 30/5/2020 11:12:00 31/5/2020 10:30:44 For
2 Document Controllers(PPMD) Source: My Tasks, Action:For Approval
ESTEBAN(chss2036) AM AM Approval
Youssef 31/5/2020 10:30:00 10/6/2020 7:34:24
3 Project Engineers(PPMD) Close Source: My Jobs, Action: Approved
Daou(youssef.daou) AM AM
Attachments
S.No. Name Path Attached By Attached On
https://dms.dpworld.com/PPMDDMS/WFHandler/JobProcess.aspx?Type=1&WFID=14815&Fxi=0&FMID=8589972831# 1/1
Document Ref # JPN-OME-000-AD-MAT-1049 Rev. 2 Date: 5 Nov 2019 Sheet:
APPROVAL VIDE THIS DOCUMENT SHALL NOT IN ANY WAY RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITIES FROM THE COMPLIANCE TO THE CONTRACT CONDITIONS
ANDTHE SPECIFICATIONS NOR ENTITLE HIM FOR ANY VARIATION CLAIM.
ECG-OPN-ISF20/R1/24.10.2017