Professional Documents
Culture Documents
Adobe Scan 17 Feb 2022
Adobe Scan 17 Feb 2022
Adobe Scan 17 Feb 2022
FOUNDATION DESIGNER
sOIL &CONCRETE TESTING
STRUCTURAL CONCRETE STRUCTURAL ENGINEERS
FINDINGS:
Properties of Sub-Soil Strata
Water Table Status
SPT-Valuue
Safe bearing Capacity
tialCALlesOCO
Plot No 31
FORWARDED TO
ER. A.C. BULCHANDANI
OFFICE: BLOCK-6, PLOT NO. 31, WARD 3-8, NEAR ST. XAVIER'S SCHOOL, TAGORE ROAD, ADIPUR (KUTCH) 370 205.
TEL: (02836) 265486 MOBILE : 98252 17209
ABSTRACT
The report is presented herewith analyses based on thorough study of the geotechnical
investigation results.
By making test bores and collecting disturbed and undisturbed soil samples.
By testing the soil in laboratory to clarify it and to determine the engineering properties
of soil.
An analysis was made to derive the allowable bearing capacity, taking into consideration with
the future possibilities. Based on such analysis of the soil properties, the conclusions are made
Recommendations are also given, after a thorough and careful study of the present soil
conditions, regarding the suitability of the type of foundation, and regarding the precautions
and protective measures to be taken if found necessary.
INDEX
SR.
NO. DESCRIPTION
GENERAL
2 FIELD INVESTIGATIONS
3 LABORATORY TESTING
4 SUB-SOIL PROFILE
5 WATER TABLE
9 NOTATIONS
10 REFERENCES
11 BORE LOGS
12 TABLES
FIELD INVESTIGATION ONE bores of 100 mm. dia bores were put down
to the depth of 4.00 mt. at proposed site of
construction by Our skilled and experienced site
personnel by using Rotary boring.
Standard Penetration Test The standard penetration test was carried out by split
spoon sampler confirming to IS - 2131-1981. The split
spoon sampler assembly is divided in three parts. One
is cutting shoe of 38 mm inside dia and 51 mm out
side diameter with 75 mm length. The second is split
body of same diameter and 508 mm in length. The
third is driving head with ball of same dia meters and
180 mm in length. The drive weight assembly consist
of 65 kg. weight hammer and 750 mm free fall guide
rod.
Before conducting the Standard Penetration Test we
had cleaned the trial pit by shell then lowered thee
S.P.T. sampler with A rod and conducted the
Standard Penetration Test in accordance with IS 2131-
1981.
Bore- BH1-
BH1(2.0M)
Assumption
Size of foundation 2.0mx2.0m
Width of footing(B) 2 m
Length of footing(L) 2 m
Depth of foundation(below GL) 2 m
Depth (below GL) 2 m
Shear parameters at depth 1.5 m
C 0.33 Kg/cm2
0 15.2 Degree
Type of failure Govern Local shear
According to IS 6409-1981 for Local shear failure
Qd= 0.67CN'c*sc*dc*ic+q(N'q-1)'sq'dqtiq+0.5BrN'r'sr'dr'irW'
Where
Qd= Net Ultimate Bearing Capacity
based on general shear failure
C Cohesion in Kg/cm2 0.33
N'c,N:9.Nr Bearing capacity factor
15.2 Degree
N'c 9.7
N'g= 2.7
N'r 0.9
SC,Sq.sr Shape factor
B/L= 1
SC 1+.2B/L 1.2
sq 1+.2B/L 1.2
srE 1-.4B/L 0.6
ic,iq,ir Inclination factor
ic 1 No inclination
iq= 1
ir
dc,dq.dr Depth factor(0>10)
(N*0)^.5 tan(45+0/2) 1.0
D/B 1
dc 1+35Df/B 1.35
dq DC-DC-1/Ng 1.22
dr 1.00
Correction for water table
a1=water table below oting 0.00 Water table below G.L.
a2=water tableabove footing 0.00 not encountered
2
Df 2
a2/Df 0.00 ( ground water table
a1/B O CORRECTION
wg 1
wy
q=Effective surcharge at the YXD 2.0424 /m2
base level of foundation Bulk unit Wt of foundation
Y soil in T/m3 1.84 tUm3
D Depth of foundation 2m
Net Ultimate Bearing Capacity Qd 40.82 tm2
Qsafe Qd/2.5 16.3 t/m2
Say 16.0 ttm2
CHECKFORSETTLEMENT CRITERIA
BH1(2.0M)
Mid depth
2r
2 m
D 2rm
C 0.20
eo 0.65
Yd 1.61 gm/cCC
Net load at base(qsafe-q)
qsafe 16 tUm2
q=YdxD 3.2195976 tUm2
Net load at base(qsafe-q) 12.780402 t/m2
PO-Original over burden pressure at 3.0 mt below GL at mid depth
D 3 m
P0-1.78x3 4.8293963 Um2
Area at base(2x2) 4 m2
Area atmid depth(5x5) 25 m2
Increase in pressure at mid Net Load x(Area at base/Area at
depth(Dp) mid depth)
Dp 2.04 Um2
Settlement (S)= cc/(1+eo)xHxlog((Po+Dp)/Po)
5.6725597 cm
56.725597 mm
Correction of rigidity factor & Depth factor
Rigidity factor 0.9
Depth factor 0 S6
Settlement (Sf)= 33.7
Permissible settlement in C-Phi Soil hence 5OMM
Summary of Safe bearing Capacity of Soil & Permissible Settlement.
Critically of BH1 &BH2
GroupBORE HOLE Depth below Safe bearing Maxmium Permissible
NO.
Maxmium settlement |REMARKS
G.L. Capacity. settlement in C-Phi type in C-Phi type Soil as
Soil for Isolated footing of |per shear
frame structures. parameters..
m) (t/m2) (mm) kg/cm2
BH1(2.0M) 2.0 16.0 50.0 33.7 OK
BH1(1.80M) 1.8 15.5 50.0 33.3 OK
RECOMMENDATIONS
& CONCLUSIONS
Looking to the site
conditions and type of structures
proposed
ON PLOT NO. B-67, SHAKTINAGAR-GANDHIDHAM, OF SHANKER LAL
NATHURMAL KOURANI.
The following conclusions are drawn and recommendations
are given accordingly.
The net safe bearing capacity for Individual column footing of size 2.0mt X 2.Omt:
Of bore hole BH1.
2. Ground water table was not encountered below G.L. in the boreholes bh1 at the time of
investigation up to 4m.
3. The top soil is not having any swelling properties and hence can be used for back or plinth
filling purpose.
4. Precautions shall be taken to keep the foundations free from variation in water content due
etc..
to leakages in services lines, rains
5. If the soil strata encountered during actual excavations are found different from strata
mentioned in the Report, the matter should be reported to us for reconsideration.
ALAEC
ECHICA tcrid C
P l o t No. 31 St.
V...dt,
(uejau) sidea
JeÁe jo sseuyoiuL| u go