RES2020-11684 Lee County ePlan

PROPERTY ADDRESS:
4513-4515 19th STREET S.W., LEHIGH ACRES, FL 33973.
LEGAL DESCRIPTION:
LOT 9, BLOCK 6, UNIT 5, LEHIGH ACRES, ACCORDING TO THE MAP OR PLAT THEREOF AS RECORDED IN PLAT BOOK 15, PAGE 85, PUBLIC RECORDS OF LEE

N
COUNTY, FLORIDA. ANY QUESTIONS REGARDING
THE DRAWINGS, DESIGNS AND
INFORMATION REPRESENTED

VACANT LAND
HEREIN PLEASE CONTACT:

BLOCK 6
LOT 8
OLYMPUS DESIGNS GROUP

5621 STRAND BLVD, SUITE 308


NAPLES, FL 34110
239 306-2324
info@olympusdesigns.net

125.00' REVISIONS
No. Description Date
41.67' 49.33' 8.00' 26.00'

10

1'
15.17'

.8
0.

99
27

19.17'
'
APPLICABLE CODES

PROPOSED -6TH EDITION (2017) FLORIDA


SEPTIC TANK BUILDING CODE
-6TH EDITION (2017) FLORIDA
A/C EXISTING CODE
-2014 STANDARD NATIONAL
ELECTRICAL CODE

DIGITAL SEAL

ELEV. +0' - 0"

FFE 103.95'NAVD

19th STREET S.W.


10.00'

(50' Total R/W)


CONCRETE DRIVEWAY
100.00'

DRAIN FIELD
ELEV. -0' - 4"
BLOCK 6

3.00'
DUPLEX

ELEV. -0' - 4"


LOT 17

10.00'
CONCRETE DRIVEWAY
34.83' Max Guerra
26.00' 2020.12.03
PROPOSED CULVERT
23:50:29

18.50' ASPHALT PAVEMENT


41.67' 34.00'
A/C
'00'05-

16.50' PARKWAY
19.16'
THIS DESIGN HAS BEEN PREPARED
UNDER SUPERVISION, DIRECTION
15.16'

AND CONTROL OF:


'
46

99
MG Engineering Consulting Services, Inc.
0.

3640 19th/ Ave SW

.7
10

8'
Naples, FL 34117
Phone: (239) 595 5465
maxguerra@mg-engineering.us
125.00' 25.00'
M
G
BLOCK 6
DUPLEX

FLOOD ZONE: X
LOT 10

SITE PLAN PROPOSED DUPLEX BASE ELEVATION: N/A

PROPERTY OF OLYMPUS DESIGNS GROUP. COPYRIGHT © 2020.


CROWN OF ROAD ELEVATION: 100.17'
1" = 10'-0" RESIDENCE FFE: 103.95' HABITAT SOLUTION
GROUP
4513-4515 19TH ST. S.W. - 10342404

SITE PLAN
NOTE TO CONTRACTOR: NOTES:
Project Number
CONTRACTOR SHALL COMPLY WITH THE LEE COUNTY SEC. 33-1434. ARCHITECTURAL 1- CERTIFIED SURVEYOR TO VERIFY PLACEMENT AND ELEVATIONS OF STRUCTURES.
STANDARDS. 2- CONTRACTOR SHALL VERIFY DRAIN FIELD AND SEPTIC TANK DIMENSIONS AND Date 11/20
MECHANICAL EQUIPMENT INCLUDING, BUT NOT LIMITED TO, AIR CONDITIONING UNITS, LOCATIONS WITH THE SEPTIC CONTRACTOR PRIOR COMMENCEMENT OF Drawn by JG
POOL PUMPS, GENERATORS AND WELL TANKS, MUST BE SCREENED FROM VIEW OF THE CONSTRUCTION. Notes DS
PUBLIC RIGHT-OF-WAY AND ADJACET RESIDENTIAL PROPERTIES WITH LANDSCAPING, 3- CONTRACTOR SHALL REVIEW DRAIN FIELD & F.F.E ELEVATIONS WITH THE PLUMBER
FENCING, OR BOTH. FENCING MUST BE CONSISTENT WITH SECTION 34-1742. BEFORE COMMENCEMENT OF CONSTRUCTION IN ORDER TO AVOID REQUIRING A SEPTIC
PUMP TANK.

SP
Scale 1" = 10'-0"
RES2020-11684 Lee County ePlan

PROPERTY ADDRESS:
4513-4515 19th STREET S.W., LEHIGH ACRES, FL 33973.
LEGAL DESCRIPTION:
LOT 9, BLOCK 6, UNIT 5, LEHIGH ACRES, ACCORDING TO THE MAP OR PLAT THEREOF AS RECORDED IN PLAT BOOK 15, PAGE 85, PUBLIC RECORDS OF
LEE COUNTY, FLORIDA. ANY QUESTIONS REGARDING
THE DRAWINGS, DESIGNS AND
INFORMATION REPRESENTED
HEREIN PLEASE CONTACT:

OLYMPUS DESIGNS GROUP

5621 STRAND BLVD, SUITE 308


NAPLES, FL 34110
239 306-2324
info@olympusdesigns.net

REVISIONS
No. Description Date

APPLICABLE CODES

-6TH EDITION (2017) FLORIDA


BUILDING CODE
-6TH EDITION (2017) FLORIDA
EXISTING CODE
-2014 STANDARD NATIONAL
ELECTRICAL CODE

DIGITAL SEAL

Max Guerra
2020.12.03
23:49:54
EXTERIOR PERSPECTIVE
'00'05-
THIS DESIGN HAS BEEN PREPARED
UNDER SUPERVISION, DIRECTION
SATELLITE VIEW LOCATION AND CONTROL OF:

MG Engineering Consulting Services, Inc.


3640 19th/ Ave SW
DRAWING INDEX AREA SUMMARY UNIT A Naples, FL 34117
Phone: (239) 595 5465
maxguerra@mg-engineering.us
SHEET # SHEET DESCRIPTION ENTRY 99 SF
CS COVER SHEET COVERED LANAI 111 SF M
A1 FLOOR PLAN GARAGE 219 SF
G
A2 FOUNDATION PLAN TOTAL A/C LIVING AREA 1198 SF
A3 ELEVATIONS TOTAL UNDER ROOF 1628 SF

PROPERTY OF OLYMPUS DESIGNS GROUP. COPYRIGHT © 2020.


A4 ROOF/BEAMS PLAN
A5 ELECTRICAL PLAN HABITAT SOLUTION
A6 DETAILS AREA SUMMARY UNIT B GROUP
ENTRY 99 SF 4513-4515 19TH ST. S.W. - 10342404
COVERED LANAI 111 SF
GARAGE 219 SF
TOTAL A/C LIVING AREA 1198 SF COVER SHEET
TOTAL UNDER ROOF 1628 SF
Project Number
Date 11/20
Reviewed for Code Compliance Drawn by JG
By: Andrew Nielsen Date: 1/20/2021
RES2020-11684 Notes DS

CS
Scale
RES2020-11684 Lee County ePlan

JOB DATA

ULTIMATE DESIGN WIND SPEED : 160


AREA SUMMARY UNIT A
NOMINAL DESIGN WIND SPEED : 124 ENTRY 99 SF
RISK CATEGORY : 2 COVERED LANAI 111 SF
IMPORTANCE FACTOR : 1.0 GARAGE 219 SF 61' - 8"
BUILDING OCCUPANCY CLASSIFICATION : RESIDENTIAL
BUILDING CONSTRUCTION TYPE : 5B TOTAL A/C LIVING AREA 1198 SF 16' - 0" 1' - 4" 12' - 10" 1' - 4" 12' - 10" 1' - 4" 16' - 0"
EXPOSURE CATEGORY : B TOTAL UNDER ROOF 1628 SF
OPENING PROTECTION :

0' - 8"

0' - 8"

0' - 8"
1' - 4"

1' - 4"
INTERNAL PRESSURE COEFFICIENTS : +0.18, -0.18 (ENCLOSED)

FLOOR LIVE LOAD : I/360 LIVE, I/240 DEAD AREA SUMMARY UNIT B COVERED LANAI COVERED LANAI

6' - 10"
ROOF LIVE LOAD : I/360 LIVE, I/240 DEAD ELEV. -0' - 4" ELEV. -0' - 4"
ENTRY 99 SF ANY QUESTIONS REGARDING

5' - 6"

5' - 6"
(SUPPORTING PLASTER CEILING) THE DRAWINGS, DESIGNS AND
COVERED LANAI 111 SF INFORMATION REPRESENTED
THE STRUCTURAL COMPONENTS ON THIS PLANS ARE IN COMPLIANCE GARAGE 219 SF 7' - 2" 25 8' - 10" 7' - 3" 3 7' - 3" 7' - 3" 3 7' - 3" 8' - 10" 25 7' - 2" HEREIN PLEASE CONTACT:
WITH THE 6TH EDITION FLORIDA BUILDING CODE, WIND LOAD TOTAL A/C LIVING AREA 1198 SF
COMPLIANCE AND ITS RESISTANCE TO GRAVITY AND DESIGN OLYMPUS DESIGNS GROUP
TOTAL UNDER ROOF 1628 SF
PRESSURES GENERATED BY A WIND VELOCITY OF 170 MPH 5621 STRAND BLVD, SUITE 308
13' - 0" 2' - 0" 14' - 2" 14' - 2" 2' - 0" 13' - 0"
NAPLES, FL 34110
239 306-2324

CLOSET

CLOSET
(2)F-2868

(2)F-2868
6' - 1"

6' - 1"
WIND VELOCITY (MPH.) 160 1 HR. FIRE WALL info@olympusdesigns.net
IMPORTANCE FACTOR 1.00 (SEE SECTION 1/A1)
EXPOSURE CATEGORY B REVISIONS
INTERNAL PRESSURE COEFFICIENT ( +,-) 0.18
No. Description Date
MEAN ROOF HEIGHT (FT) 14'-0"
MASTER BEDROOM MASTER BEDROOM

14' - 0"

14' - 0"
BUILDING WIDTH (FT) 61'-8"

CLOSET
F-2868

F-2868
CLOSET
BUILDING LENGTH (FT) 64'-2''

17' - 8"

17' - 8"
4' - 0"

4' - 0"
ROOF SLOPE
ENCLOSED STRUCTURE
5:12
WATER
UNIT A UNIT B WATER

8' - 0"

8' - 0"
SYSTEM SYSTEM

22' - 7"

22' - 7"
GREAT ROOM GREAT ROOM

3' - 6"

3' - 6"
APPLICABLE CODES

2868

2868
(3)2"X10" ELEV. +0' - 0" ELEV. +0' - 0"
W/(1) LAYER 1/2" PLY.
BETWEEN EACH 2"X10" SD-2668 SD-2668 -6TH EDITION (2017) FLORIDA
2''x6'' STUDS @ 16'' O,C, (2) 2''x6'' 2''x4'' STUDS @ 16'' O.C. NEW WALL 2''x4'' 4' - 0" 4' - 0"
BUILDING CODE
3' - 4" 6' - 0" 3' - 0" 2' - 0" 2' - 0" 3' - 0" 6' - 0" 3' - 4" -6TH EDITION (2017) FLORIDA

SD-2668

SD-2668
0' - 8" EXISTING CODE

CLOSET

CLOSET
BATH BATH -2014 STANDARD NATIONAL

(2) F-2668

(2) F-2668
5' - 4"

5' - 4"

5' - 4"

5' - 4"
22 22 ELECTRICAL CODE

4' - 0" 10' - 2" 10' - 2" 4' - 0"


(2)2''x6'' DIGITAL SEAL
0' - 6" 3' - 4" 3' - 4" 0' - 6"

8' - 0"

8' - 0"
D

D
(2) F-2668

(2) F-2668
5' - 7"

5' - 7"
3' - 6"

3' - 6"
DOOR OPEN

2' - 4"

2' - 4"

49' - 4"
D/W D/W

64' - 2"

W
10' - 0"

10' - 0"
25 DEN DEN 25

1' - 10" 1' - 10"

PANTRY

PANTRY
5' - 6"

5' - 6"
KITCHEN KITCHEN

4' - 1"

4' - 1"

7' - 10"
F-2468

F-2468
8' - 1"
2868 8' - 3 1/2" 8' - 3 1/2" 2868
BOT PLATE BOT PLATE

Max Guerra

2' - 1"

2' - 1"
REF SEE NOTE B. REF

2868

2868
TYP. DETAIL BEARING WALL TYP. DETAIL NEW NON BEARING WALL BATH BATH

5' - 0"

5' - 0"

5' - 0"

5' - 0"
N.T.S N.T.S 22
22
7' - 9" 3' - 9" 6' - 0" 6' - 0" 3' - 9" 7' - 9"
DETAIL A W/H W/H

2020.12.03

2868

2868
10' - 2"

10' - 2"
20 MIN. RATE DOOR 6'' WOOD BEARING WALL 20 MIN. RATE DOOR
N.T.S 2868
( SEE DETAIL A/ A1)
2868

2' - 2"

2' - 2"
4' - 0" 4' - 0"
CLOSET FOYER THIS DOORS BE EQUIPPED
WITH A SELF -CLOSING DEVICE.
THIS DOORS BE EQUIPPED
WITH A SELF -CLOSING DEVICE.
FOYER CLOSET
23:49:18

5' - 0"

5' - 0"
5/8" TYPE X GYP. BD. FBC 2017-R302.5 FBC 2017-R302.5
PRE-ENGINEERD
(1HR FIRE RATE) STD (2) F-3068 ATTIC ATTIC (2) F-3068
4' - 0"

4' - 0"
(TO BE IN A/H A/H
COMPLIANCE U338).
TRUSSES @ 24" A/C 1 ACCESS
(IN ATTIC) (IN ATTIC)
ACCESS
1 A/C
'00'05-

15' - 10"
O.C.
15' - 7"

NO ILL FASTERNERS-VERIFY WITH


PRODUCT APPROVAL

19' - 5"

19' - 5"
5/8" TYPE X GYP.
10' - 2"

10' - 2"
CONTINUOUS URETHENE
SEALANT BD. (1HR FIRE
SEALANT BEAD
RATE)
BEDROOM BEDROOM
STOOL PER SPEC BETWEEN FLANGE BLOCK GARAGE GARAGE THIS DESIGN HAS BEEN PREPARED
ELEV. -0' - 4" ELEV. -0' - 4" UNDER SUPERVISION, DIRECTION
6''

7' - 8"

7' - 8"
SEAL WINDOW TO BLOCK 2"X6" PTW TOP REINFORCEMENT
BOLT TO CONC. AND CONTROL OF:
8"

1 X P.T NAILERS
ATEPPED PRE-CAST (1)BOND BM. W/ 1-#5
11' - 6" 11' - 6" MG Engineering Consulting Services, Inc.

11' - 8"

11' - 8"
CONCRETE SILL CONT.
6''

5/8" TYPE X GYP. 3640 19th/ Ave SW


WATER PROOFING COAT 25 25
1/2'' GYPSUM WALLBOARD BD. (1HR FIRE Naples, FL 34117
APPLY ON SILL EXTENDED
RATE)
6'' DOWN AND 6'' UP THE Phone: (239) 595 5465
WALL 6' - 5" 5' - 1" 4' - 1" 2' - 9" 2' - 9" 2' - 9" 6' - 5" 6' - 5" maxguerra@mg-engineering.us
MASONRY WALL R-4.1 INSULATION
CEMENTITIOUS FINISH 12' - 10" 5' - 6" 11' - 6" 11' - 6" 5' - 6" 12' - 10"
ISULATION/FURRING
8" REINF. MASONRY
M
#5 REBAR VERTICAL FROM 2 2
BLOCK. 1 HOUR ENTRY
6' - 8"

6' - 8"
FIRE WALL.(SEE
FTG'. TO TIE BEAM IN POURED ENTRY G

8' - 0"
CONCRETE CELL @ 48" O.C. ELEV. -0' - 4" ELEV. -0' - 4"
NOTE A)
6' - 10" 6' - 5" 12' - 2" 6' - 5" 6' - 10"

2' - 8"

2' - 8"

PROPERTY OF OLYMPUS DESIGNS GROUP. COPYRIGHT © 2020.


2'' x 6'' PTW
BOLT TO CONC.

SH WINDOW SILL-CMU HABITAT SOLUTION


1' - 4"

1' - 4"

1' - 4"

1' - 4"
4'' CONC.
N.T.S SLAB GROUP
TOP OF SLAB 1' - 4" 4' - 10" 1' - 4" 1' - 4" 4' - 10" 1' - 4"
ELEV. +0' - 0" 4513-4515 19TH ST. S.W. - 10342404
11' - 6" 7' - 6" 23' - 8" 7' - 6" 11' - 6"

SECTION 1/ FIRE WALL FLOOR PLAN LEGEND


FLOOR PLAN
1/2" = 1'-0" 1/4" = 1'-0" EXTERIOR CMU WALL
INTERIOR WALL Project Number
WOOD BEARING WALL Date 11/20

NOTE A: NOTE B:
Drawn by
Notes
JG
DS
TABLE 722.3.2
NOT LESS THAN 1/2"
DOOR SCHEDULE WINDOW SCHEDULE
MINIMUM EQUIVALENT THICKNESS (in) Max. Max. Max. Max.
GYP. BOARD OR EQUIVALENT Type
OF BEARING OR NONBEARING CONCRETE MASONRY WALLS: 2.8
TYPE OF AGGREGATE: CALCAREOUS OR SILICEOUS GRAVEL R302.5,6
Type MarkModel

1 ENTRY
Width

3' - 0" 8' - 0"


Height
Comments
EXTERIOR
Positive
Pressure
43.0
Negative
Pressure
-47.5
Type Mark

22
Width

3' - 0"
Height

2' - 2" SINGLE HUNG


Description

IMPACT
Comments

4
Count Positive Negative
Pressure Pressure
46.1 -50.0
A1
FIRE-RESISTANCE RATING (hours): 1 Scale
2 GARAGE 9' - 0" 8' - 0" EXTERIOR 40.6 -44.5 25 3' - 0" 5' - 3" SINGLE HUNG IMPACT 6 44.9 -48.8 As indicated
3 SLIDING 8' - 0" 8' - 0" EXTERIOR 40.6 -44.5
NOTE: CONTRACTOR TO VERIFY WINDOWS AND DOORS ROUGH OPENINGS AS PER THE Reviewed for Code Compliance
MANUFACTURER SPECIFICATIONS. By: Andrew Nielsen Date: 1/20/2021
RES2020-11684
RES2020-11684 Lee County ePlan

FOUNDATION GROUND FLOOR NOTES 61' - 8"

1. FLOOR SLAB IS A 4'' CONC. SLAB-ON-GRADE (fc=3000 psi) WITH 6 X 6 W1.4 X W1.4 W.W.F. @ MID-DEPTH (NOT 16' - 0" 1' - 4" 12' - 10" 1' - 4" 12' - 10" 1' - 4" 16' - 0"
SHOWN) ON WELL COMPACTED & TREATED SOIL OVER 6 MIL. VAPOR BARRIER. REFER TO DETAIL. SOIL SHALL BE
COMPACTED TO 95% MODIFIED PROCTOR PER ASTM D 1557 IN LIFTS NOT EXCEED 12''.
2 2
2. FOUNDATIONS ARE DESIGNED FOR 3000 PSF. GENERAL CONTRACTOR SHALL VERIFY THE VALIDITY OF THIS
ASSUMPTION. CMU COL. W/ 3-#5 A2 CMU COL. W/ 2-#5 A2 CMU COL. W/ 3-#5
VERTICAL. VERTICAL. VERTICAL.
3. CENTER OF LOAD SHALL COINCIDE WITH CENTER OF FOOTING U.N.O.
4. ALL CONCRETE TO HAVE A MINIUM OF 3000 PSI COMPRESSIVE STRENGHT WITH THE WATER/CEMENT RATIO OF 0.5

0' - 8"

0' - 8"
MAXIMUM.

1' - 4"

1' - 4"
5. ● INDICATES ADDITIONAL #5 IN CMU WALLS.
6. REFER TO ARCHITECTURE PLANS FOR ALL DIMENSIONS. 1 1
7. ALL REINFORCEMENT SHALL BE GRADE 60. A2 F-16 F-16 A2

6' - 10"
8. BUILDING PAD SHALL BE COMPACTED 5' - 0'' EACH SIDE OF THE BUILDING AND SLOPE AT 30 DEGREES TO GRADE. ELEV. -0' - 4" ELEV. -0' - 4"

F-16
ANY QUESTIONS REGARDING

F-16
5' - 6"

5' - 6"
FOOTING SHALL EMBED AT LEAST 12''. IF THESE CONDITIONS CAN NOT BE MET, THE BUILDING SHALL BE ON STEM THE DRAWINGS, DESIGNS AND
WALL FOUNDATION. NOTIFY ENGINEER PRIOR TO CONSTRUCTION. 7' - 2" 12' - 1" 8' - 0" 3' - 3" 3' - 3" 8' - 0" 12' - 1" 7' - 2" INFORMATION REPRESENTED
9. SOIL SHALL BE TREATED FOR TERMITE PROTECTION AS PER SECTION R318 OF F.B.C 6TH EDITION 2017. HEREIN PLEASE CONTACT:

OLYMPUS DESIGNS GROUP

MASONRY WALL REINFORCEMENT CEMENT 5621 STRAND BLVD, SUITE 308


F-16 F-16 F-16 F-16 NAPLES, FL 34110
1. WALL REINFORCEMENT SHALL BE DOWELED FROM FOUNDATION AND BE CONTINUOUS TROUGH SOLID GROUTED 239 306-2324
CELLS AND BE HOOKED OVER TOP REINFORCEMENT OF UPPER BEAMS, MINIMUM LAP SPLICE SHALL BE 48 BAR 1 HR. FIRE WALL info@olympusdesigns.net
(SEE SECTION 1/A1)
DIAMETERS. FOR HORIZONTAL WALL REINFORCEMENT, @ EVERY OTHER COURSE.
2. WALL REINFORCEMENT IS FOLLOWS: #5 @ 48'' O.C. PROVIDE 1 #5 AT ALL WALL INTERSECTIONS, CORNERS, AND 4' - 0" 4' - 0" REVISIONS
EACH SIDE OF OPENINGS AND 2 #5 EACH SIDE OF OPENINGS LARGER THAN 6' - 0''. No. Description Date
3. WALL SEGMENT BELOW AND ABOVE THE OPENINGS SHALL BE REINFORCED SAME AS WALL.

F-16

F-16
4. MASONRY GROUT = 2500 P.S.I.
5. MASONRY WALL COMPRESSIVE STRENGTH OF f'm = 1500 P.S.I.

17' - 8"

17' - 8"
6. MORTAR TYPE M OR S WITH 1900 P.S.I COMPRESSIVE STRENGTH.
WATER
UNIT A UNIT B WATER

8' - 0"

8' - 0"
SYSTEM SYSTEM
12 1/2"A.P.A. RATED SHEATHING
SIMPSOM TRUSS ANCHOR HETA20 FOR APPLICABLE CODES
PITCH 5 PRE-ENGINEERED STD UPLIFTS LESS THAN 1810W,OR META20 ELEV. +0' - 0" ELEV. +0' - 0"
TRUSSES @ 24" O.C. FOR UPLIFTS LESS THAN 1450W.
-6TH EDITION (2017) FLORIDA
R-30 BATT INSULATION SHINGLE ROOF OVER 30# FELT OVER SHEATHING ON 4'' THICK POWDER CONCRETE SLAB W / 6X6 OR FIBER 4'' THICK POWDER CONCRETE SLAB W / 6X6 OR FIBER BUILDING CODE
WOOD TRUSSES. SHALL BE FASTENED TO ROOF GLASS, #10 WELDED WIRE MESH REINF. POURED OVER GLASS, #10 WELDED WIRE MESH REINF. POURED OVER -6TH EDITION (2017) FLORIDA

F-16
FRAMING W/ 8d RING-SHANK NAIL AT 6" ON CENTER 6 MIL. VAPOR BARRIER ON WELL COMPACTED TERMITE 6 MIL. VAPOR BARRIER ON WELL COMPACTED TERMITE EXISTING CODE
AT EDGE & 6' ON CENTER AT INTERMEDIATE FRAMING. 2' - 4" 4' - 11" 4' - 11" TREATED BACK FILL (TYPICAL FOR ALL SLAB). TREATED BACK FILL (TYPICAL FOR ALL SLAB). 4' - 11" 4' - 11" 2' - 4" -2014 STANDARD NATIONAL
COMPACTED TO 95% OF MODIFIED PROCTOR. COMPACTED TO 95% OF MODIFIED PROCTOR. ELECTRICAL CODE
TOP OF BOND BEAM +9'-4''
(SEE BEAM SCHEDULE) 8"

5/8 DRYWALL
CEILING OR 1/2'' SAG 4 DIGITAL SEAL
2"X6" PTW GALV. ALUM. DRIP EDGE
RESISTANT. 1'-4'' O.H. A2

8' - 0"

8' - 0"
BOLT TO CONC. ALUM. FASCIA

D
PERFORATED 1
ALUM. SOFFIT

2' - 7"

2' - 7"
TOP REINFORCEMENT A2
8"

(1)BOND BM. W/1-#5 CONT. D/W D/W

64' - 2"

W
F-16

F-16
FINISH STUCCO 5' - 5" 5' - 5"
1
1/2 GYP. BD. ON 1X2" PT. A2

7' - 10"
8' - 1"
FURRING @ 24 C.O.
3
A2 WC-1 WC-1
R-4.1 INSULATION #5 REBAR VERTICAL FROM F-2 F-2

8" REINF. MASONRY BLOCK


FTG'. TO TIE BEAM IN POURED
CONCRETE CELL @ 48" O.C
(VERIFY WINDOWS OPENINGS)
2' - 2" 2' - 8" 2' - 5" 2' - 5" 2' - 8" 2' - 2"
Max Guerra
WALLS FILLED W/ 2500 p.s.i. W/H W/H
2020.12.03
48'' BAR DIAM.

GROUT AND REINF.AS PER PLAN. F-16 F-16

24' - 7"

24' - 7"
6'' WOOD BEARING WALL
4' - 0" 4' - 0"
4" CONC. SLAB
WWM 10/10 6X6
TOP OF SLAB 0'-0''
( SEE DETAIL A/ A1)

23:48:43
ATTIC ATTIC
F-16 F-16
4' - 0"

4' - 0"
16"

A/H A/H
VAPOR BARRIER A/C ACCESS
(IN ATTIC) (IN ATTIC)
ACCESS A/C
'00'05-

15' - 10"
SOIL TO BE COMPACTED TO
15' - 7"

F-16

F-16
95% MODIFIED PROCTOR
16" X 16" CONC. FOOTING PER ASTM D 1557
W/2- #5 CONT.

F-16
F-16
TYP. WALL SECTION THIS DESIGN HAS BEEN PREPARED
1 ELEV. -0' - 4" ELEV. -0' - 4" UNDER SUPERVISION, DIRECTION
1/2" = 1'-0"
AND CONTROL OF:

F-16
F-16

F-16
8'' X 8'' THICKENED
ELEV. -0' - 4" ELEV. -0' - 4" MG Engineering Consulting Services, Inc.
4'' CONC. SLAB EDGE W/ 1 - #5
F-16 F-16 3640 19th/ Ave SW
Naples, FL 34117
Phone: (239) 595 5465
8"

VAPOR BARRIER 6' - 5" 6' - 5" 1' - 2" 3' - 2" 1' - 2" maxguerra@mg-engineering.us
1' - 2" 3' - 2" 1' - 2" 6' - 5" 6' - 5"
8"
WELL COMPACTED FILL
F-16 F-16 M
6' - 8"

6' - 8"
2
THICKENED EDGE G

8' - 0"
1/2" = 1'-0" CMU COL. W/ 4-#5 CMU COL. W/ 4-#5
6' - 10" 1' - 10" 9' - 2" 3' - 0" 9' - 2" 1' - 10" 6' - 10"

2' - 8"

2' - 8"

PROPERTY OF OLYMPUS DESIGNS GROUP. COPYRIGHT © 2020.


VERTICAL. VERTICAL.
(2) 2X6 TOP PLATE W/ 18 GA SIMPSON SPH4
(OR EQUAL) U STRAP W/ (8)10d NAILS EACH
HABITAT SOLUTION
1' - 4"

1' - 4"

1' - 4"

1' - 4"
SIDES.
F-1 F-1 F-1 F-1
2''X6'' CMU COL. W/ 4-#5
GROUP
BEARING WALL W/ STUDS 1' - 4" 4' - 10" 1' - 4" VERTICAL. 1' - 4" 4' - 10" 1' - 4"
4513-4515 19TH ST. S.W. - 10342404
16'' O.C & BRACED EVERY 1/3
(1) SIMPSON HTT4 STUDS. 11' - 6" 7' - 6" 23' - 8" 7' - 6" 11' - 6"

4'' CONC. SLAB. 1/2'' X 8'' J-BOLT


@ 24'' O.C. 16'' X 16'' CONC. FTG. 2 2 FOUNDATION
W/2 - #5 CONT.
PT BOTT. PLATE
A2
FOUNDATION PLAN
A2
LEGEND
PLAN
Project Number
1 HR FIRE WALL FOOTING
1/4" = 1'-0"
4"

WALL Date 11/20


48'' BAR. DIAM.
16"

4'' CONC. SLAB THE FOLLOWING DISCIPLINES ARE TO 8" REINF. MASONRY BLOCK Drawn by JG
WWM 10/10 16'' X 16'' CONC. FTG. BE FIELD REVIEWED AND/OR FIELD WALL. Reviewed for Code Compliance
6X6 W/ 2 - #5 CONT. INSPECTED FOR CODE COMPLIANCE By: Andrew Nielsen Date: 1/20/2021
Notes DS
ELECTRICAL MECHANICAL PLUMBING RES2020-11684
1' - 4"

A2
16"

VAPOR BARRIER SOIL TO BE COMPACTED TO FOOTING SCHEDULE WOOD COLUMN SCHEDULE


95% MODIFIED PROCTOR Type Mark Description
PER ASTM D 1557. VAPOR SOIL TO BE COMPACTED MARK SIZE REINFORCEMENT
BARRIER TO 95% MODIFIED WC-1 (2)2''X6'' W/ SIMPSON (1) HTT4 BOTT & LGT2 GIRDER TIE-DOWN TOP. Scale As indicated
PROCTOR PER ASTM D F-1 26'' X 26'' X 16'' W/4 - #5 EA. WAY. BOTT
WOOD BEARING WALL SECTION FIRE WALL SECTION 1557
3 4 F-2 30'' X 30'' X 12'' W/5 - #5 EA. WAY. BOTT
1/2" = 1'-0" 1/2" = 1'-0" F-16 16'' X 16'' 16''X16'' CONC. FOOTING W/2-#5 CONT.
RES2020-11684 Lee County ePlan

12

TOP OF ENTRY
BEAM
11' - 4"
TOP OF B. BEAM
9' - 4"
ELEVATION
7' - 4" ANY QUESTIONS REGARDING
THE DRAWINGS, DESIGNS AND
INFORMATION REPRESENTED
HEREIN PLEASE CONTACT:

OLYMPUS DESIGNS GROUP

5621 STRAND BLVD, SUITE 308


NAPLES, FL 34110
FINISH FLOOR 239 306-2324
0' - 0" info@olympusdesigns.net

DECORATIVE STUCCO
REVISIONS
FRONT ELEVATION No. Description Date
1/4" = 1'-0"

12

APPLICABLE CODES

-6TH EDITION (2017) FLORIDA


BUILDING CODE
TOP OF B. BEAM -6TH EDITION (2017) FLORIDA
9' - 4" EXISTING CODE
-2014 STANDARD NATIONAL
ELEVATION ELECTRICAL CODE
7' - 4"

DIGITAL SEAL

FINISH FLOOR
0' - 0"

REAR ELEVATION
1/4" = 1'-0"
12

5
12
Max Guerra
TOP OF ENTRY
BEAM
11' - 4"
2020.12.03
TOP OF B. BEAM
9' - 4"
ELEVATION
23:48:10
7' - 4"
'00'05-
THIS DESIGN HAS BEEN PREPARED
UNDER SUPERVISION, DIRECTION
AND CONTROL OF:
FINISH FLOOR
0' - 0" MG Engineering Consulting Services, Inc.
3640 19th/ Ave SW
Naples, FL 34117
Phone: (239) 595 5465
RIGHT ELEVATION maxguerra@mg-engineering.us

1/4" = 1'-0" M
12

5
G

PROPERTY OF OLYMPUS DESIGNS GROUP. COPYRIGHT © 2020.


HABITAT SOLUTION
TOP OF ENTRY
BEAM
GROUP
11' - 4" 4513-4515 19TH ST. S.W. - 10342404
TOP OF B. BEAM
9' - 4"
ELEVATION ELEVATIONS
7' - 4"
Project Number
Date 11/20
Reviewed for Code Compliance Drawn by JG
By: Andrew Nielsen Date: 1/20/2021
Notes DS
RES2020-11684

FINISH FLOOR
0' - 0"
A3
LEFT ELEVATION Scale 1/4" = 1'-0"
1/4" = 1'-0"
RES2020-11684 Lee County ePlan

CLG. TYPE 1/2'' EXTERIOR GYP. CLG. TYPE 1/2'' EXTERIOR GYP.
MINIMUM ROOF VENT AREA PER FBC R806.2 ROOF NOTES: SHEATING SHEATING
(TO BE IN COMPLIANCE W/R1604.9- 8F16-1B/1T 8F16-1B/1T (TO BE IN COMPLIANCE W/R1604.9-
AREA: 3256 SQ. FT. 1.ROOF TRUSSES SHALL BE DESIGNED BY TRUSS MANUFACTURER. SHOP DRAWINGS FBC 2017) TOP ELEV.+9' - 4" TOP ELEV.+9' - 4" FBC 2017)
VENTING REQUIRED: 3256 X 144 SQ. IN./SQ. FT. X 1/300 SQ. IN. VENT/SQ. IN. ROOF = 1563 SQ. IN SHALL BE SUBMITTED TO THE PROJECT ENGINEER FOR REVIEW PRIOR TO PRODUCTION.
2.TRUSS MANUFACTURED SHALL PROVIDE UPLIFT & REACTION VALUES FOR INDIVIDUAL
TRUSSES, REFER TO THE TRUSS DRAWING FOR LAYOUT.

TOP ELEV.+9' - 4"

TOP ELEV.+9' - 4"


NOTE: 3.ROOF SHEATHING SHALL CONSIST OF 1/2" MIN. A.P.A. RATED SHEATHING. 4-PLY CDX LAID

8F16-1B/1T

8F16-1B/1T
1/150 IS REQUIRED UNLESS AT LEAST 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THE PERPENDICULAR TO TRUSSES NAILED @ 6" O.C. ALONG BOUNDARY EDGES, 6" O.C. ALONG
REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER EDGES AND 10" O.C. INTERMEDIATE W/ 8d COMMONS. WIND EXPOSURE WIND EXPOSURE
PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO 4.BRACE TRUSSES PER T.P.I. H.I.B.-91, AS REVISED.
MORE THAN 3 FEET (914 mm) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MESURED 5.PROVIDE SIMPSON HETA20 W/16 10d X 1 1/2" FOR UPLIFT UP TO 1890 LBS. PROVIDE (2)
VERTICALLY, WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR SIMPSON HETA20 @ OPPOSITE SIDE OF GIRDER TRUSS. UNLESS OTHERWISE NOTE.
CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS 6.ALL CHANGES OF THE TRUSS LAYOUT SHALL BE APPROVED BY THE ENGINEER. 8F24-1B/1T 8F16-1B/1T 8F16-1B/1T 8F24-1B/1T
WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MOE THAN 3 FEET (914 mm) TOP ELEV.+9' - 4" TOP ELEV.+9' - 4" TOP ELEV.+9' - 4" TOP ELEV.+9' - 4"
BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED.
RTB RTB
DISCRETE ROOF AREAS TO HAVE PERCENTAGE OF TOTAL VENTING PROPORTIONAL TO THE BASE OFFSET. 0' - 0" BASE OFFSET. 0' - 0"
PERCENTAGE OF AREA. SMALL ROOF AREAS SUCH AS ENTRY TOWERS MAY BE VENTED W/
SOFFIT VENTS ONLY PROVIDED VENTILATION IS BASED ON THE 2X INCREASE IN NET FREE
AREA. 1 HR. FIRE WALL
(SEE SECTION 1/A1) ANY QUESTIONS REGARDING
NOTE: VERTICAL REINFORCEMENT
IN GROUTED CELL TYP. THE DRAWINGS, DESIGNS AND

BASE OFFSET. 0' - 0"

BASE OFFSET. 0' - 0"


ROOF VENTS SHOWN ARE BASED ON OFF RIDGE VENTS HAVING A MINIMUM NET FREE AREA OF INFORMATION REPRESENTED
130 SQ. INCHES & PERFORATED SOFFIT MATERIAL HAVING A MIN. NET FREE OF 11.74 SQ. BENT BARS, SAME SIZE HEREIN PLEASE CONTACT:
INCHES. CONTRACTOR REQUIRED TO VERIFY ALL ROOF VENTING PER THE CALCULATION IN BARS AS HORIZONTAL

RTB

RTB
FBC R806.2. REINFORCEMENT
OLYMPUS DESIGNS GROUP

A9

A9
48 BAR DIAM. LAP

A
LOCATE ALL ROOF VENT PENETRATIONS MIN. 18'' FROM RIDGES OR VALLEYS.
5621 STRAND BLVD, SUITE 308
UNIT A UNIT B NAPLES, FL 34110

(TYP.)
HORIZONTAL TIE BEAM
REINFORCEMENT 239 306-2324
CLG. ELEV.10' - 4"A.F.F. CLG. ELEV.10' - 4"A.F.F.
info@olympusdesigns.net
HORIZONTAL TIE BEAM
REINFORCEMENT

REVISIONS
No. Description Date
TYP. TIE BEAM INTERSECTION BENT
FIRE RETARDANT TREATED
AND LAP BAR DETAIL PLYWOOD AT ROOF DECK TO

TOP ELEV.+9' - 4"

TOP ELEV.+9' - 4"


EXTEND AWAY FROM EACH SIDE

8F24-1B/1T

8F24-1B/1T
N.T.S. OF DEMISING WALL A MIN. 48''
CLG. ELEV.9' - 4"A.F.F. CLG. ELEV.9' - 4"A.F.F.

VERTICAL REINFORCEMENT
IN GROUTED CELL TYP.
APPLICABLE CODES

BASE OFFSET. 0' - 0"

BASE OFFSET. 0' - 0"


-6TH EDITION (2017) FLORIDA

48 BAR DIAM. LAP

RTB

RTB
BUILDING CODE
-6TH EDITION (2017) FLORIDA

(TYP.)
EXISTING CODE

TOP ELEV.+9' - 4"

TOP ELEV.+9' - 4"


HORIZONTAL TIE BEAM
-2014 STANDARD NATIONAL

8F24-1B/1T

8F24-1B/1T
REINFORCEMENT
CLG. ELEV.9' - 4"A.F.F. CLG. ELEV.9' - 4"A.F.F. CLG. ELEV.9' - 4"A.F.F. CLG. ELEV.9' - 4"A.F.F. ELECTRICAL CODE

DIGITAL SEAL
TYP. TIE BEAM CORNER BENT AND

BASE OFFSET. 0' - 0"

BASE OFFSET. 0' - 0"


LAP BAR DETAIL

RTB

RTB
N.T.S.

TOP ELEV.+9' - 4"

TOP ELEV.+9' - 4"


WBW WBW

8F24-1B/1T

8F24-1B/1T
BASE OFFSET. 0' - 0" BASE OFFSET. 0' - 0"
2 #5 EACH FACE
CLG. ELEV.9' - 4"A.F.F. CLG. ELEV.9' - 4"A.F.F.
CLG. ELEV.9' - 4"A.F.F. CLG. ELEV.9' - 4"A.F.F.

28''
ADD LGT2 ADD LGT2
28''

Max Guerra
RTB RTB
BASE OFFSET. 0' - 0" ATTIC ATTIC BASE OFFSET. 0' - 0"
A/H A/H

BASE OFFSET. 0' - 0"

BASE OFFSET. 0' - 0"


WBW-1 ACCESS ACCESS WBW-1
TIE BEAM #5 VERTICAL IN (IN ATTIC) (IN ATTIC)
BASE OFFSET. 0' - 0" BASE OFFSET. 0' - 0"
REINFORCING GROUT FILLED CELL

RTB

RTB
DETAIL FOR RAISED BEAM CLG. ELEV.9' - 4"A.F.F.
8F16-1B/1T
TOP ELEV.+11' - 4" GR GR
8F16-1B/1T
TOP ELEV.+11' - 4"
2020.12.03

BASE OFFSET. 0' - 0"


CLG. ELEV.9' - 4"A.F.F.

BASE OFFSET. 0' - 0"

BASE OFFSET. 0' - 0"


N.T.S.

BASE OFFSET. 0' - 0"


BASE OFFSET. -0' - 4"

BASE OFFSET. -0' - 4"

RTB
23:47:26

WBW-1

WBW-1
RTB

BASE OFFSET. 0' - 0"


BASE OFFSET. 0' - 0"
FW-5050 FW-5050

RTB

RTB
FIRE RATED DOOR FIRE RATED DOOR

WBW-1
WBW-1
www.acudor.com
FW-5050
'00'05-
U.S.A.: info@acudor.com / 800.722.0501 RTB RTB
CANADA: info@acudor.ca / 844.228.3671 APPLICATION BASE OFFSET. 0' - 0" BASE OFFSET. 0' - 0"
INTERNATIONAL: info@acudorintl.com
(905) 428.2240 • FOR WALLS AND CEILINGS
FIRE RATED DOOR • THIS DOOR SHOULD BE USED IN WALLS WHEN TEMPERATURE RISE OR HEAT 8F24-1B/1T 8F24-1B/1T
QTY NOMINAL SIZE A B C D D F LOCK TRANSMISSION IS A FACTOR. TOP ELEV.+9' - 4" TOP ELEV.+9' - 4"
22x30 (559 x 762) 29.78 (756) 21.78 (553) 24 (610) 32 (813) 22.12 (562) 30.12 (765) 2
PRODUCT FEATURES RTB THIS DESIGN HAS BEEN PREPARED

TOP ELEV.+11' - 4"

TOP ELEV.+11' - 4"


22x36 (559 x 914) 35.78 (909) 21.78 (553) 24 (610) 38 (965) 22.12 (562) 36.12 (917) 2
24x36 (610 x 914) 35.78 (909) 23.78 (604) 26 (660) 38 (965) 24.12 (613) 36.12 (917) 2 • INSULATED DOOR PANEL CLG. TYPE 1/2'' EXTERIOR GYP. BASE OFFSET. -0' - 4" CLG. TYPE 1/2'' EXTERIOR GYP. UNDER SUPERVISION, DIRECTION

TOP ELEV.+11' - 4"

TOP ELEV.+11' - 4"


WIND EXPOSURE WIND EXPOSURE

8F16-1B/1T

8F16-1B/1T
24x48 (610 x 1219) 47.78 (1214) 23.78 (604) 26 (660) 50 (1270) 24.12 (613) 48.12 (1222) 2 • CONCEALED HINGE SHEATING SHEATING AND CONTROL OF:

8F16-1B/1T

8F16-1B/1T
30x30 (762 x 762) 29.78 (756) 29.78 (756) 32 (813) 32 (813) 30.12 (765) 30.12 (765) 2 (TO BE IN COMPLIANCE W/R1604.9- 8F16-1B/1T 8F16-1B/1T (TO BE IN COMPLIANCE W/R1604.9-
35.78 (909) 35.78 (909) • SELF-CLOSING FBC 2017) FBC 2017)
36x48 (914 x 914) 38 (965) 38 (965) 36.12 (917) 36.12 (917) 2 TOP ELEV.+9' - 4" TOP ELEV.+9' - 4" MG Engineering Consulting Services, Inc.
36x48 (914 x 1220) 47.78 (1214) 35.78 (909) 38 (965) 50 (1270) 36.12 (917) 48.12 (1222) 2 • SELF LATCHING
3640 19th/ Ave SW
• INSIDE LATCH RELEASE Naples, FL 34117
DOOR CLOSING SPRING BRAKETS
ARE SUPPLIED ON DOORS LARGER THAN
18'' x 18'' (FOR CEILING INSTALLATION ONLY)
WALLS AND CEILINGS

FOR WALLS THIS DOOR HAS A "UL" AND "ULC",


1 1/2 HOUR "B" LABEL, WITH A MAXIMUM
FW-5050 ACCESS DOOR SPECIFICATIONS:
MATERIAL: STEEL OR STAINLESS STEEL
ROOF/ BEAMS PLAN Phone: (239) 595 5465
maxguerra@mg-engineering.us
TEMPERATURE OF 250 DEGREES AFTER
30 MINUTES. DOOR: 20 GAUGE, FILLED WITH 2" THICK FIRE RATED INSULATION 8F16-1B/1T
TOP ELEV.+11' - 4" 1/4" = 1'-0" 8F16-1B/1T
TOP ELEV.+11' - 4"
E
SPRING CLOSER
FOR FIRE RATED CEILINGS, THIS DOOR HAS BEEN
APPROVED BY WARNOCK HERSEY INTERNATIONAL MOUNTING FRAME: 16 GAUGE, FLANGE TO BE 1" WIDE M
FOR 3 HOURS (MAX. SIZE 24" x 36").
HINGE: CONCEALED
6.25''
FIRE RATING (WALLS): UL — 1-1/2 HOUR "B" LABEL. ULC — 2 HOUR "B" LABEL. MAX COMPONENTS AND CLADDING G
MASONRY STRAP (OPTIONAL)
SIZE: 36 X 48. (CEILINGS): WARNOCK HERSEY INTERNATIONAL 3 HOUR RATED IN POSITIVE AND NEGATIVE PRESSURES PER TABLE R301 2(2)
SELF LATCHING BOLT
A NON-COMBUSTIBLE CEILING. 1 HOUR RATED IN A COMBUSTIBLE CEILING. MAX OF THE FLORIDA BUILDING CODE 6TH EDITION, 2017

PROPERTY OF OLYMPUS DESIGNS GROUP. COPYRIGHT © 2020.


20 GA CRS. MAT'L RESIDENTIAL OVERHANG LOADS HAVE BEEN CALCULATED
2'' FIRE RATED INSULATION
SIZE: 24 X 36 USING ASCE 7-10. 5 h
C
16 GA CRS. MAT'L STANDARD LATCH: UNIVERSAL SELF-LATCHING BOLT, OPERATED BY EITHER A HABITAT SOLUTION
.875
KNURLED KNOB OR FLUSH KEY. WHEN MASTER KEYING IS REQUIRED, DOORS
CAN BE PREPARED FOR MORTISE CYLINDER LOCKS. a
5

4
θ
4
a
ELEVATION SCHEDULE GROUP
BASE
FINISH: STEEL: 5 STAGE IRON PHOSPHATE PREPARATION WITH PRIME COAT OF 5 5 MARK DESCRIPTION TOP CONSTRAIN 4513-4515 19TH ST. S.W. - 10342404
OFFSET
CONCEALED WHITE BAKED-ON ENAMEL. STAINLESS STEEL: TYPE 304 - #4 SATIN POLISH
HINGE
.25'' DIA.
a= End Zone Width IN ALL CASES. a a RTB (1)8''X 8'' BOND BEAM W/(1)#5 CONT. Up to level: TOP OF B. BEAM -0' - 4"
COUNTER SUNK
F RTB (1)8''X 8'' BOND BEAM W/(1)#5 CONT. Up to level: TOP OF B. BEAM 0' - 0"
A
UNIVERSAL ACCESS
D WALLS
WBW WOOD BEARING WALL Up to level: TOP OF B. BEAM 0' - 0"
ROOF/BEAMS
a a a a a a a
a
a WBW-1 DUAL WOOD BEARING WALL Up to level: TOP OF ENTRY BEAM 0' - 0" PLAN
a 3 2 2 3 a 3 2 3 3 2 3 a 3 2 3 Project Number
1.75'' 1
2 2 Date 11/20
2 2
B
2.56'' Drawn by JG
20 GA CRS. MAT'L
LINTEL & BOND BEAM LEGEND
PRECAST-LINTEL SCHEDULE
2 1 2 2 1 2
2 1 1 2 2 1 2 2 1 2
a a Notes DS
STANDARD FEATURES: UNIVERSAL SELF LATCHING BOLT- OPERATED BY KNURLED KNOB / FLUSH KEY,
WITH INSIDE TURN RELEASE. F=FILLED WITH GROUT / U= UNFILLED
OPTIONS:
LOCK TYPE
CARBON STEEL, PRIME COAT BAKED ENAMEL FINISH
MATERIAL FINISH 2 2 DESCRIPTION ELEVATION AT TOP COUNT
STAINLESS STEEL #4 SATIN POLISH 2 2 QUANTITY OF #5 REBAR AT
RIM CYLINDER LOCK
PREPARED FOR MOTICE CYLINDER LOCK OTHER OTHER 1 8F16-1B/1T 9' - 4" 8 BOTTOM OF LINTEL CAVITY
ALL FIRE RATED:
SPECIAL SIZES CAN BE ORDERED, BUT BASIC CONSTRUCTION
MUST REMAIN CONSTANT TO COMPLY WITH UL AND ULC REGULATIONS.
a 3 2 2 3 a 3 2 3 3 2 3 a 3

a
2 3
8F24-1B/1T
8F16-1B/1T
9' - 4"
11' - 4"
10
8
8F16-1B/1T A4
QUANTITY OF #5 REBAR AT TOP
GABLE ROOF θ≤ 10º GABLE ROOF 10º < θ≤ 45º HIP ROOF 10º < θ≤ 30º
JOB NAME: NOMINAL HEIGHT Scale As indicated
APPROVED BY:
CUSTOMER: DATE: WINDOW AND DOOR DESIGN PRESSURES NOMINAL WIDTH
Reviewed for Code Compliance
COPYRIGHT © 2016 ACUDOR PRODUCTS LTD. - ALL RIGHTS RESERVED
VALUES SHOWN ADJACENT TO EACH OPENING ON THE PLANS INDICATE WIND PRESSURE ON By: Andrew Nielsen Date: 1/20/2021
THAT PARTICULAR OPENING PLUS AND MINUS SIGNS SIGNIFY PRESSURE ACTING TOWARD AND RES2020-11684
AWAY FROM SURFACES RESPECTIVELY.
RES2020-11684 Lee County ePlan

ELECTRICAL LEGEND COVERED LANAI COVERED LANAI

SINGLE SWITCH

3 THREE WAY SWITCH

DUPLEX RECEPTACLE

GFI GFI RECEPTACLE SD SD

CLOSET

CLOSET
RECESSED LIGHT MASTER BEDROOM MASTER BEDROOM ANY QUESTIONS REGARDING
THE DRAWINGS, DESIGNS AND
INFORMATION REPRESENTED
EXHAUST FAN HEREIN PLEASE CONTACT:

TV

TV
OLYMPUS DESIGNS GROUP

CLOSET

CLOSET
SD
SMOKE DETECTOR GREAT ROOM GREAT ROOM 5621 STRAND BLVD, SUITE 308
NAPLES, FL 34110
TELEPHONE JACK WATER WATER 239 306-2324
SYSTEM SYSTEM info@olympusdesigns.net
TV
T V / CABLE
SD SD REVISIONS
No. Description Date
CEILING LIGHT FIXTURE TV TV

WALL MOUNT LIGHT FIXTURE

CLOSET

CLOSET
BATH BATH
VP VP

WALL BRACKET LIGHT

GFI
GFI
VP
VAPOR PROOF RECESSED LIGHT APPLICABLE CODES

SD SD -6TH EDITION (2017) FLORIDA


EXTERIOR FLOOD LIGHT

D
BUILDING CODE

GFI
GFI
-6TH EDITION (2017) FLORIDA
GFI GFI GFI GFI EXISTING CODE
PENDANT LIGHT D/W D/W -2014 STANDARD NATIONAL

W
GFI
GFI
ELECTRICAL CODE

GFI
GFI
CEILING FAN W / LIGHTS

PANTRY

PANTRY
DIGITAL SEAL
DEN KITCHEN KITCHEN DEN

GFI
GFI
TV TV

GFI
GFI
REF REF
CEILING FAN W/O LIGHTS BATH BATH

3
3
GFI GFI GFI GFI GFI GFI GFI GFI

VP VP

SD CM GFI GFI CM SD
W/H W/H

GFI
GFI
PANEL BOX

CLOSET FOYER FOYER CLOSET


GARAGE GARAGE

3
3
FLOURESCENT

GFI
GFI
CM
CARBON MONOXIDE ALARM WITHIN 10'
OF EACH BEDROOM
A/C
BEDROOM
3 3
ATTIC
ACCESS
A/H
(IN ATTIC)
A/H
(IN ATTIC)
ATTIC
ACCESS
3 3
BEDROOM
A/C Max Guerra
DOOR OPENING DOOR OPENING
2020.12.03

GFI

GFI
Residential Standard Calculation

TV

TV
ENTRY ENTRY 23:46:51

GFI
GFI
SD SD
200 Ampere
rated meter can 200 Amp
Main Breaker Panel
'00'05-
120/240v

THIS DESIGN HAS BEEN PREPARED


UNDER SUPERVISION, DIRECTION
Grounding electrode AND CONTROL OF:
shall comply with
Circuit Panel
Sec. 250.52 MG Engineering Consulting Services, Inc.
3640 19th/ Ave SW
Naples, FL 34117
Phone: (239) 595 5465
maxguerra@mg-engineering.us
G.E.D shall comply
with Sec. 250.66 M
ELECTRICAL PLAN G
Demand Load 1/4" = 1'-0" THE FOLLOWING DISCIPLINES ARE TO
141 Amperes BE FIELD REVIEWED AND/OR FIELD

PROPERTY OF OLYMPUS DESIGNS GROUP. COPYRIGHT © 2020.


INSPECTED FOR CODE COMPLIANCE
ELECTRICAL MECHANICAL PLUMBING
Neautral Load HABITAT SOLUTION
2 in Min. size Conduit
74 Amperes GROUP
#3/0 cu Ungrounded conductors 4513-4515 19TH ST. S.W. - 10342404
#4 cu Neutral conductor (min.)

UNDERGROUND RISER ELECTRICAL


Service Conductors by Utility Reviewed for Code Compliance PLAN
By: Andrew Nielsen Date: 1/20/2021
RES2020-11684
Project Number
Date 11/20
Drawn by JG
NOTE: Notes DS
ALL BRANCH CIRCUITS THAT SUPPLY 125 V, SINGLE PHASE, 15 & 20 AMPERE RECEPTACLE OUTLET SHALL BE
PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER(S) IN DWELLING UNIT ALL LIVING AREA.

2014 N.E.C/6TH EDITION F.B.C 2017 A5


Scale As indicated
RES2020-11684 Lee County ePlan

MIN. 1X4 P.T. BUCK W/30 NOTE: APPLY POLYURETHANE ADHESIVE TO BUCK
GENERAL STRUCTURAL NOTES: BEVEL-APPLY TO TOP & OR EQUAL
MINIMUM OF ONE FILLED CELL
BOTH SIDES OF WINDOW
1. FOUNDATIONS: OPENINGS W/1 #5 VERTICAL PER PLAN
SOIL STATEMENT- VISUAL INSPECTION OF THE SITE SHOWS A SOIL OF
LIMESTONE WITH SANDY POCKETS AND WITH A LAYER OF TOPSOIL. THIS 3/16''X2-3/4'' CORROSIVE RESISTANT 8'' CMU WALL
CONTINUOUS SEALANT (TAPCON) CONC. SCREWS INSTALLED 4'' NOTE: WINDOW ATTACHEMENT TO BUCK PER
LIMESTONE HAS A SAFE BEARING CAPACITY IN EXCESS OF 2,000 psf. ATTHE TIME
OF CONSTRUCTION A LICENSED ARCHITECT OR PROFESSIONAL ENGINEER SHALL FROM EA. END AND @18'' O.C. TRHU-OUT. MR. RECOMMENDATIONS
SUBMIT TO THE BUILDING OFFICIAL A LETTER ATTESTING THAT THE SITE HAS DECORATIVE STUCCO
BEEN OBSERVED AND THE FOUNDATIONS ARE SIMILAR TO THOSE UPON WHICH FINISH OVER CONC. P.T. 1''X4'' WOOD BUCK
THE DESIGN IS BASED. OFF SET 3/4''
2. CONCRETE: ANY QUESTIONS REGARDING
ALL CONCRETE TO ATTAIN A MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF 1/2'' DRYWALL
THE DRAWINGS, DESIGNS AND
3,000 PSI IN 28 DAYS. CONTINUOUS BED OF INFORMATION REPRESENTED
SEALANT HEREIN PLEASE CONTACT:
AGGREGATES TO BE CLEAN AND WELL GRADED, MAXIMUM SIZE 1''. CONCRETE CONTINUOUS BED OF SEALANT
SLUMP: 3'' MIN. TO 5'' MAX. VERTICAL CONCRETE DROP NOT TO EXCEED 8'. BUCK FASTENERS TO MASONRY TO BE ONE OF THE FOLLOWING: OLYMPUS DESIGNS GROUP
P.T. 1X4 WOOD BUCK SET IN
FULL BED OF SEALANT TYPICAL ALUMINUM WINDOW. ALL CERTIFICATION LABELS SHALL 1. 1/4'' X 3'' TAPCONS @ 16'' O.C. (MIN. 3 PER BUCK)
3. CONCRETE COVER: 5621 STRAND BLVD, SUITE 308
REMAIN FOR FINAL INSPECTION MAXIMUM TOLERANCE FOR FINAL 2. 10D FULL HEAD COIL NAIL @ 12'' O.C. NAPLES, FL 34110
TO BE AS FOLLOWS: FITING SHALL BE 1/8''. NO DOUBLE BUCKING ALLOWED 3. 8D FULL HEAD COIL NAIL @ 8'' O.C. 239 306-2324
FOOTINGS 3'' 4. 6D FULL HEAD COIL NAIL @ 6'' O.C.
info@olympusdesigns.net
BEAMS 1.5'' TO STIRRUP
COLUMNS 1.5'' TO TIES
SLABS NOT EXPOSED TO THE WEATHER 0.75'' WINDOW HEAD AND JAMB DETAIL WINDOW INSTALLATION DETAIL
REVISIONS
No. Description Date
SLABS EXPOSED TO THE WEATHER 1.5'' SCALE: N.T.S. SCALE: N.T.S.
4. REINFORCING STEEL:
TO BE NEW HIGH STRENGTH BILLET STEEL DEFORMED AS PER ASTM A-305, AND 1/2'' DRYWALL W/1''X2'' P.T. TO
CONFORMING TO ASTM A-615, GRADE 60. LAP CONTINUOUS BARS 30-BAR NOTES: BLOCK
2''X8'' PRESS TREATED WD. JAMB
DIAMETERS, UNLESS OTHERWISE NOTED IN PLANS. HOOK DISCONTINUOUS ENDS
OF ALL TOP BARS. REINFORCING STEEL TO BE DETAILED AND FABRICATED IN W/ (4) 1/4''X2 1/2'' TAPCON TO
1. FOR WINDOW AND DOOR ATTACHMENT TO MASONRY USE BUCK IN BED APPLICABLE CODES
ACCORDANCE WITH "MANUAL OF STANDARD PRACTICE OF DETAILING CONC. BLOCK OR BETTER
OF LIQUID NAIL TO MASONRY SIDE AND TOP OF OPENING WITH ( 1 ) 3/4''
REINFORCING CONCRETE STRUCTURES", AND THE ACI BUILDING CODE 318, START 4'' FROM ENDS & 8'' O.C. -6TH EDITION (2017) FLORIDA
X .097'' POWER DRIVEN T-NAIL OR 3/16'' X 2-1/4'' TAPCONS. START AT 4''
LATEST EDITION. SUBMIT SHOP DRAWINGS FOR APPROVAL BY ENGINEER TYP. BUILDING CODE
THEN 8'' ON CENTER. ATTACH WINDOW IN ACCORDANCE WITH WINDOW -6TH EDITION (2017) FLORIDA
BEFORE FABRICATION. MANUFACTURER'S SPECIFICATIONS. EXISTING CODE
2. FOR WINDOW ATTACHMENT TO FRAME USE MINIMUM ( 4 ) 8D NAILS PER -2014 STANDARD NATIONAL
5. MASONRY: ELECTRICAL CODE
EDGE, THEN 12'' ON CENTER MAXIMUM.
REINFORCED MASONRY DESIGN & CONSTRUCTION SHALL COMPLY W/ ACI
3. FOR DOOR ATTACHMENT TO FRAME USE No.8 x 3'' STEEL SCREWS. ( 2 ) AT
530-02/ASCE 5-02/TMS 402-02 & ACI 5301.-02/ASCE 6-02/TMS 602-02.
A. ALL CONCRETE BLOCK TO BE GRADE N-2, CONFORMING TO ASTM C- 90, HEADER, ( 3 ) AT LOCK SIDE AND ( 2 ) MINIMUM EACH HINGE.
DIGITAL SEAL
WITH A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 1,900 PSI, AND A 4. CONTRACTOR AND OR SUB-CONTRACTOR TO REVIEW THE TRUSS
PRISM STRENGTH OF 1,500 PSI (MINIMUM). MORTAR SHALL BE TYPE M, WITH PLACEMENT PLAN TO COORDINATE. CEMENT PLASTER
A MINIMUM STRENGTH OF 2,500 PSI (USE PORTLAND TYPE CEMENT).
B. MASONRY WALLS SHALL BE REINFORCED HORIZONTALLY EVERY OTHER BLOCK WALL
COURSE WITH 9 GAUGE DEFORMED GALVANIZED STEEL LADDER.
C. FOR VERTICAL REINFORCEMENT, SEE PLAN AND LAP 48 BAR DIAMETERS P.T. FURRING
SL. GR. DR. JAMB TO BLK DETAIL
MINIMUM. PROVIDE FULL BED OF MORTAR FOR REINFORCED MASONRY.
D. GROUTING OF CELLS SHALL BE A CONTINUOUS OPERATION IN LIFTS NOT SCALE: N.T.S.
1/2'' GYPSUM WALLBOARD
EXCEEDING 4'-0'' AND A MAXIMUM POUR OF 12'-0'' IN HEIGHT. GROUTING TO
BE CONSOLIDATED BETWEEN LIFTS BY PUDDLING, RODDING OR 1/2'' DRYWALL W/1''X2'' P.T. TO
MECHANICAL VIBRATION. PROVIDE CLEANOUTS, AND CLEAN OUT CELLS OF BLOCK WALL BLOCK
MORTAR DROPPINGS. 1X4 OR 2X4 DOOR BUCK 2-1/4''X1/4''
E. GROUT SHALL BE A PLASTIC MIX HAVING A MAXIMUM SLUMP OF 8'' TO 10'',
TAPCONS W/ 4'' FROM TOP/BOTT.
PLACED BEFORE ANY INTIAL SET HAS OCURRED, BUT IN NO CASE MORE
THAN 1-1/2 HOURS AFTER THE MIX-DESIGN WATER HAS BEEN ADDED,
STUCCO FINISH 12'' O.C. Max Guerra
GROUT TO ATTAIN A MINUMUM 3,000 PSI COMPRESSIVE STRENGTH. DOOR TRIM MARBLE SILL
6. PRE-FABRICATED WOOD TRUSSES:
SHALL BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE TRUSS PLATE
SEALANT DOOR FRAME
2020.12.03
METAL SASH
INSTITUTE (T.P.I), LATEST EDITION. TRUSSES TO BE ERECTED FOLLOWING THE
GUIDELINES OF THE T.P.I PUBLICATION BWT-76. SUBMIT SHOP DRAWINGS W/
DOOR (SEE FLOOR PLAN)
23:45:59
LAYOUT PLAN AND INDIVIDUAL DRAWINGS FOR EACH DIFFERENT TRUSS, SIGNED PRECAST SILL
AND SEALED BY A FLORIDA REGISTERED PROFFESIONAL ENGINEER, FOR
APPROVAL BY STRUCTURAL ENGINEER PRIOR TO FABRICATION. TYPICAL EXTERIOR DOOR DETAIL CEMENT PLASTER
'00'05-
MIN. 1'' X (4) PRESS. TREATED WOOD JAMB W/ 2
GENERAL CONTRACTOR TO PROVIDE PERMANENT LATERAL BRACING OF THE SCALE: N.T.S. BLOCK WALL 1/4'' PNEUMATIC PRIVEN NAILS W/ 0.097 SHANK
BOTTOM CHORD AND THE WEB MEMBERS IN ACCORDANCE WITH THE DIA. OR BETTER START 4'' FROM ENDS & 8'' O.C. THIS DESIGN HAS BEEN PREPARED
RECOMMENDATIONS OF T.P.I BWT-76 AND THE REQUIREMENTS OF THE UNDER SUPERVISION, DIRECTION
TYP. AND CONTROL OF:
INDIVIDUAL TRUSS DESIGNS. SUBMIT PERMANENT BRACING PLAN FOR APPROVAL
BY ENGINEER PRIOR TO ERECTION. GRIDER TRUSSES TO BE BOLTED TOGETHER MG Engineering Consulting Services, Inc.
WITH 1/2'' DIA. BOLTS AT 24'' C/C AT TOP CHORD, BOTTOM CHORD, AND WEB DOOR AND WINDOW JAMB DETAIL 3640 19th/ Ave SW
Naples, FL 34117
MEMBERS. CONTRACTOR TO SUBMIT SIGNED AND SEALED SHOP DRAWINGS BY A Phone: (239) 595 5465
DELEGATED SPECIALTY ENGINEER FOR ALL TRUSS TO TRUSS CONNECTIONS. SCALE: N.T.S. maxguerra@mg-engineering.us
TRUSS MANUFACTURER TO VERIFY UPLIFT AND GRAVITY TRUSS REACTIONS CMU COLUMN

SHOWN ON FRAMING PLANS.


W/ #5 REBAR VERTICAL M
G
SUPERIMPOSED LOADS SHALL BE AS FOLLOWS: IN GROUT FILLED CELLS
PLACE #5 CORNER
INSTALL #5 REBAR
ROOF: DEAD LOAD= 20 PSF (TOP CHORD)

PROPERTY OF OLYMPUS DESIGNS GROUP. COPYRIGHT © 2020.


IN EACH CELL @ CORNERS BAR AT EACH FOTT.
10 PSF (BOTT.CHORD) OF MASONRY COLUMN. BARS 30'' AT EACH
LIVE LOAD= 20 PSF (TOP CHORD) HABITAT SOLUTION
48'' BAR DIA. LAP

SIDE.
7. WIND DESIGN CRITERIA:
GROUP

2' -6''
ALL STRUCTURAL ELEMENTS, EXPOSED TO WIND, HAVE BEEN DESIGNED PER 4513-4515 19TH ST. S.W. - 10342404
THE GUIDELINES OF THE HVHZ-FBC 6TH EDITION 2017, ASCE 7-10: RISK
CATEGORY II, ENCLOSE BUILDING, 160 MPH WIND SPEED, EXPOSURE B. SEE
CALCULATIONS FOR ADDITIONAL INFORMATION. DETAILS
CAST-IN-PLACE
8. GENERAL: REINFORCED
THE BUILDING WAS DESIGNED ACCORDING TO THE FLORIDA BUILDING CODE 6TH CONCRETE PAD Reviewed for Code Compliance Project Number
FOOTING. By: Andrew Nielsen Date: 1/20/2021
EDITION 2017. STRUCTURAL DRAWINGS SHALL BE WORKED TOGETHER WITH SEE FOUNDATION
Date 11/20
RES2020-11684
ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS TO LOCATE 2' -6'' Drawn by JG
3" CLR.

PLAN FOR DETAILS


3" CLR.
DEPRESSED SLABS, SLOPES, OPENINGS AND DIMENSIONS, ETC. DISCREPANCIES Notes DS
SHALL BE BROUGTH TO THE ATTENTION OF THE ARCHITECT BEFORE
PROCEEDING WITH THE WORK. CONTRACTOR TO VERIFY ALL DIMENSIONS AND
CONDITIONS AT JOB SITE BEFORE STARTING WORK. CONTRACTOR IS TYP. CMU COLUMN DETAIL TYP. FOOTING CORNER BAR DETAIL
RESPONSIBLE FOR ALL SHORING AND RE-SHORING REQUIRED.
SCALE: N.T.S.
SCALE: N.T.S. A6
Scale As indicated