Abstract
A requirement for widespread adoption of fuel cell vehicles in the transportation sector will be ready availability of pure hydrogen at prices
that result in operating costs comparable to, or less than, that of gasoline internal combustion engine vehicles. The existing electrical power
grid could be used as the backbone of the hydrogen infrastructure system in combination with water electrolyzers. A water electrolyzer
can contribute to the load leveling by changing operational current density in accordance with the change of electricity demand. The
optimum hydrogen generation capacity and current density of the polymer electrolyte membrane (PEM)-type water electrolyzer operated
only during the off-peak period of electricity demand in respect of both the shortest time required for start and the higher efficiency of water
electrolysis are obtained as 500 Nm3 h−1 and 30 kA m−2 , respectively. This PEM-type water electrolyzer could be used in the hydrogen
refueling stations and energy storage systems constructed around hydrogen.
© 2003 Elsevier B.V. All rights reserved.
Keywords: Water electrolyzer; Polymer electrolyte membrane; Fuel cell vehicles; Load leveling
0378-7753/$ – see front matter © 2003 Elsevier B.V. All rights reserved.
doi:10.1016/j.jpowsour.2003.11.050
230 T. Oi, Y. Sakaki / Journal of Power Sources 129 (2004) 229–237
cooled, while a net heat input is necessary at higher elec- at the surface of MEA until the PEM-type water electrolyzer
trolysis temperature. attains to the rated operational temperature from the start
Usually heat generated at economical current density of operation, temperature increase of water electrolyzer per
levels exceeds the heat required to maintain the temperature unit time is calculated as follows.
of the electrolyzer and cooling must be used in the elec- Qgen
trolyzer. This energy loss is caused by the electrode over- T = (15)
(Wi Ci )
voltage and ohmic loss. Product of the number of electrons
conducted under the water electrolysis, Faraday constant
and the difference between the electrolysis cell voltage and 4. Results and discussion
the thermoneutral voltage is changed to the energy loss.
Thus, energy loss at the surface of MEA is as follows. An active area of vertical MEA for electrolysis is set as
Qgen = (Vc − Vtn )iA (9) 0.25 m in length and 1 m in height. Width and length of
flow passage for the mixture of de-ionized water and oxy-
3.2. Heat transfer coefficient at the surface of MEA gen in compartment for the anode in the electrolysis module
is set as 1 mm and 0.25 m, respectively. The PEM-type wa-
De-ionized water in compartment for the anode in the ter electrolyzer is operated under the pressure of 1 MPa. All
electrolysis module contains the oxygen. This means that constituent parts of the PEM-type water electrolyzer are in-
the fluid in compartment for the anode in the electrolysis sulated with the glass fiber having a thickness of 40 mm to
module is two-phase flow. Quality is equal to weight fraction prevent heat from releasing. Ambient temperature is set as
of oxygen flow rate in the two-phase flow. Flow regimes of 278 K. Operation of the PEM-type water electrolyzer starts
the two-phase flow are identified with quality, such as bubble from 293 K.
flow, slug flow and annular flow. Heat transfer coefficient
of the forced convective two-phase flow accompanied with 4.1. Surface temperature of MEA
boiling in the flow regimes, such as bubble flow, slug flow
and annular flow is given as follows [14]. Surface temperature of MEA changes along the flow
passage for the mixture of de-ionized water and oxygen in
h = αhb + htp (10) compartment for the anode in the electrolysis module from
α is a coefficient indicating the contribution of nucleate boil- the inlet to exit. Surface temperature of MEA becomes
ing. As oxygen is generated by electrolysis, α can be con- maximum at the exit. In the case where inlet temperature
sidered as zero. Schrock and Grossman proposed the heat of de-ionized water supplied to compartment for the anode
transfer coefficient of forced convective two-phase flow for in the electrolysis module is 353 K, dependences of the
the vertical upward flow as follows [15]. maximum surface temperature of MEA on the amount of
2.5hw de-ionized water supplied to compartment for the anode in
htp = 0.75 (11) the electrolysis module per unit area of MEA are shown in
Xtt
Fig. 6.
WL 0.9 ρG 0.5 µL 0.1 Surface temperature of MEA is almost constant in the
Xtt = (12) range of 1 kg m−2 s−1 or more at each current density. At the
WG ρL µG
current density of 10 kA m−2 surface temperature of MEA is
WL De 0.8 Pr0.4 almost constant also below 1 kg m−2 s−1 . The higher current
hw = 0.023λL L
(13)
Af µ L De density becomes except the current density of 10 kA m−2 in
the range of less than 1 kg m−2 s−1 , the more drastically sur-
3.3. Surface temperature of MEA face temperature of MEA becomes higher. Thermal decom-
position temperature of Nafion in H+ form was measured
Energy loss generated at the surface of MEA must be as 558 K [16]. With reference to this thermal decomposition
cooled with the heat transfer between the surface of MEA temperature the rated amounts of de-ionized water supplied
and the de-ionized water supplied to compartment for the to compartment for the anode in the electrolysis module
anode in the electrolysis module. Surface temperature of were determined in order not for the surface temperature
MEA is given as follows. of MEA to exceed the temperature of 373 K as shown in
Qgen Table 1.
Tm = Tw + (14)
hA
4.2. Flow regime in compartment for the anode in the
3.4. Temperature increase of the PEM-type water electrolysis module
electrolyzer
Flow regimes in compartment for the anode in the elec-
In the case where heat exchanger in the circulation loop trolysis module on the flow regime map identified by Grif-
for the de-ionized water does not remove the heat generated fith and Wallis [17] in a vertical upward flow are shown in
T. Oi, Y. Sakaki / Journal of Power Sources 129 (2004) 229–237 235
Fig. 6. Dependences of the maximum surface temperature of MEA on the amount of de-ionized water supplied to compartment for the anode in the
electrolysis module per unit area of MEA.
Fig. 8. Breakdown of weight and heat capacity for the PEM-type water electrolyzer of 500 Nm3 h−1 in hydrogen generation capacity and 30 kA m−2 in
rated current density.
with the increase of current density. As a result total heat of time from the start of operation are shown in Fig. 10.
capacity of stainless steal decreases with the increase of cur- Time required to attain to the water electrolysis temperature
rent density in the range from 10 to 30 kA m−2 and keeps of 353 K as a function of current density for each hydrogen
almost constant in the range of 30 kA m−2 or more. Conse- generation capacity is shown in Fig. 11. Time required to
quently, total sum of heat capacity of de-ionized water and attain to the water electrolysis temperature of 353 K be-
stainless steal has a minimum value at the current density of comes shorter with the increase of current density in the
30 kA m−2 . Energy loss of water electrolysis, namely heat range from 10 to 30 kA m−2 and keeps almost constant in
generated at the surface of MEA increases with the increase the range of 30 kA m−2 or more in accordance with both the
of current density. total sum of heat capacity of de-ionized water and stainless
steal and energy loss of the water electrolysis as a function
4.4. Change of temperature in the PEM-type water of current density as shown in Fig. 9. Time required to
electrolyzer attain to the water electrolysis temperature of 353 K for the
PEM-type water electrolyzer of 500 Nm3 h−1 in hydrogen
Temperatures of the PEM-type water electrolyzer of generation capacity at the current density of 30 kA m−2 is
500 Nm3 h−1 in hydrogen generation capacity as a function the shortest.
Fig. 9. Heat capacities and energy loss of the water electrolysis as a function of current density for the PEM-type water electrolyzer of 500 Nm3 h−1 in
hydrogen generation capacity.
T. Oi, Y. Sakaki / Journal of Power Sources 129 (2004) 229–237 237
5. Conclusions
Fig. 10. Temperature of the PEM-type water electrolyzer of 500 Nm3 h−1
in hydrogen generation capacity as a function of time from the start of References
operation.
[1] http://www.iae.or.jp/DATA/TENBOU/1997-HUKAHEIJYUN/0shou.
html.
[2] http://www.fepc.or.jp/english/info/energyandenv/07.html.
[3] B.D. McNicol, D.A.J. Rand, K.R. Williams, J. Power Sources 100
(2001) 47.
[4] J.M. Ogden, M.M. Steinbugler, T.G. Kreutz, J. Power Sources 79
(1999) 143.
[5] J.M. Ogden, Int. J. Hydrogen Energy 24 (1999) 709.
[6] C.E. Thomas, I.F. Kuhn Jr, B.D. James, F.D. Lomax Jr., G.N.
Baum, Int. J. Hydrogen Energy 23 (1998) 507.
[7] C.E. Thomas, B.D. James, F.D. Lomax Jr., I.F. Kuhn Jr., Int. J.
Hydrogen Energy 25 (2000) 551.
[8] http://www.chuden.co.jp/.
[9] T.A. Zawodzinski Jr., C. Derouin, S. Radzinski, R.J. Sherman, V.T.
Smith, T.E. Springer, S. Gottensfeld, J. Electrochem. Soc. 140 (1993)
1041.
[10] T. Okada, H. Satou, M. Okuno, M. Yuasa, J. Phys. Chem. B 106
(2002) 1267.
[11] http://www.tech.nedo.go.jp/WWWROOT/HOKOKUSYO/
DOWNLOAD/01000152313.pdf.
[12] R.L. LeRoy, C.T. Bowen, J. Electrochem. Soc. 127 (1980) 1954.
[13] R.L. LeRoy, J. Electrochem. Soc. 130 (1983) 2158.
Fig. 11. Time required to attain to the water electrolysis temperature of [14] J.R. Fair, Petroleum Refiner 39 (1960) 105.
353 K as a function of current density. [15] V.E. Schrock, L.M. Grossman, USAEC Report TID-14639 (1959).
[16] H. Takenaka, E. Torikai, Y. Kawami, N. Wakabayashi, T. Sakai,
The optimum hydrogen generation capacity and opera- Denki Kagaku, Electrochemistry 52 (1984) 351 (in Japanese).
[17] P. Griffith, G.B. Wallis, Trans. ASME C83 (1961) 307.
tional current density of the PEM-type water electrolyzer op- [18] J.R. Fair, D.E. Steinmeyer, W.R. Penney, B.B. Crocker, in: R.H.
erated only during the off-peak period of electricity demand Perry, D.W. Green (Eds.), Perry’s Chemical Engineer’s, Handbook,
in respect of both the shortest time required for start and the McGraw-Hill Book Company, New York, 1984, p. 18–85.