GENERAL NOTES:

1. DO NOT SCALE FROM THE DRAWINGS.

2. ALL DIMENSIONS ARE IN MILLIMETERS


UNLESS NOTE OTHERWISE.

3. THIS DRAWING SHOULD BE READ IN


CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL,
MECHANICAL, ELECTRICAL AND CIVIL
DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

4. MANUFACTURER RESERVES THE RIGHT TO


MODIFY THE INTERNAL STRUCTURE SHOWN
IN THE APPROVED SHOP DRAWING DUE TO
SAFETY AND MAINTENANCE REASONS. THE
OVERALL APPEARANCE OF LIGHT FITTING
WILL REMAIN UNCHANGED AS PER
APPROVED SHOP DRAWING.

5. WE RESERVE THE RIGHT TO


MANUFACTURE IN ACCORDANCE TO OUR
UNDERSTANDING OF THE DESIGN INTENT
AND SPECIFICATION REQUIREMENTS AND
WILL NOT BE PRODUCING FULL SIZE
SAMPLES FOR EACH PIECE - SKETCH
DETAILS, FINISH SAMPLES AND DRAWINGS
ONLY WILL BE SUBMITTED FOR APPROVAL.
8060

REQUEST FOR INFORMATION (RFI)


1.

2.
320 x STRING OF ACRYLIC
STARLETS

Approval Stamp
CODE A APPROVED
Work can proceed

CODE B APPROVED WITH COMMENTS


Work can proceed incorporating the
comments
CODE C APPROVED WITH COMMENTS
8MM THK Work can proceed incorporating the
comments; revise and re-submit
PERFORATED CODE D NOT APPROVED
Re-submit
ALUMINIUM IN BRASS
Designer Review
FINISH; DIVIDED IN TO
Signed
SECTIONS
8410

Contractor Review
10 x 50P 20 DEGREES LED
Signed
MODULE IN ECLIPSE 3 MINI
Reviewed for By (Name) Date
ROUND FIX HOUSING Architectural
Structural
Mechanical
Electrical
Other

20 x 50P 10 DEGREES
LED MODULE IN ECLIPSE
3 MINI ROUND FIX 0 04 MAR 19 FOR APPROVAL JBC

HOUSING Rev Date Description Draw App.


REVISION SCHEDULE

Project:

AGORA MALL

Client:

Project Consultant:

Interior Consultant:

Sub Contractor:

Drawing Title

Plan View Winch Support - Plan View ILLUMINATED HANGING STARLETS


DETAILS - VSI03 (SKYLIGHT 2)

Location
-----
Quantity Weight
1 SET ---
Sheet Original Scale Size
1 OF 3 1:100 A3
Drawn Checked Autorized
JOJE VSP TL
Date: Date: Date:
04 MAR 19 ----- -----
Drawing Number Rev

TLX-AM-IHS-VSI03 00
GENERAL NOTES:
1. DO NOT SCALE FROM THE DRAWINGS.

2. ALL DIMENSIONS ARE IN MILLIMETERS


UNLESS NOTE OTHERWISE.

3. THIS DRAWING SHOULD BE READ IN


CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL,
MECHANICAL, ELECTRICAL AND CIVIL
DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

4. MANUFACTURER RESERVES THE RIGHT TO


MODIFY THE INTERNAL STRUCTURE SHOWN
IN THE APPROVED SHOP DRAWING DUE TO
SAFETY AND MAINTENANCE REASONS. THE
OVERALL APPEARANCE OF LIGHT FITTING
WILL REMAIN UNCHANGED AS PER
APPROVED SHOP DRAWING.

5. WE RESERVE THE RIGHT TO


MANUFACTURE IN ACCORDANCE TO OUR
UNDERSTANDING OF THE DESIGN INTENT
AND SPECIFICATION REQUIREMENTS AND
WILL NOT BE PRODUCING FULL SIZE
SAMPLES FOR EACH PIECE - SKETCH
DETAILS, FINISH SAMPLES AND DRAWINGS
ONLY WILL BE SUBMITTED FOR APPROVAL.

REQUEST FOR INFORMATION (RFI)


1.

2.

Approval Stamp
CODE A APPROVED
Work can proceed

CODE B APPROVED WITH COMMENTS


Work can proceed incorporating the
comments
CODE C APPROVED WITH COMMENTS
Work can proceed incorporating the
comments; revise and re-submit
CODE D NOT APPROVED
Re-submit
Designer Review

Signed

Contractor Review

Signed

12540
12540
Reviewed for By (Name) Date
Architectural
Structural
Mechanical
Electrical
Other

0 04 MAR 19 FOR APPROVAL JBC

Rev Date Description Draw App.


REVISION SCHEDULE

Project:

AGORA MALL

Client:

Project Consultant:

Interior Consultant:

Sub Contractor:

Drawing Title

A-A Section B-B Section ILLUMINATED HANGING STARLETS


DETAILS - VSI03 (SKYLIGHT 2)

Location
-----
Quantity Weight
1 SET ---
Sheet Original Scale Size
2 OF 3 1:100 A3
Drawn Checked Autorized
JOJE VSP TL
Date: Date: Date:
04 MAR 19 ----- -----
Drawing Number Rev

TLX-AM-IHS-VSI03 00
GENERAL NOTES:
1. DO NOT SCALE FROM THE DRAWINGS.

2. ALL DIMENSIONS ARE IN MILLIMETERS


UNLESS NOTE OTHERWISE.

3. THIS DRAWING SHOULD BE READ IN


CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL,
MECHANICAL, ELECTRICAL AND CIVIL
DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS.

4. MANUFACTURER RESERVES THE RIGHT TO


MODIFY THE INTERNAL STRUCTURE SHOWN
IN THE APPROVED SHOP DRAWING DUE TO
SAFETY AND MAINTENANCE REASONS. THE
OVERALL APPEARANCE OF LIGHT FITTING
WILL REMAIN UNCHANGED AS PER
APPROVED SHOP DRAWING.
16 x SS M16 THREADED ROD/BOLT STRUCTURAL BEAM RHS300x100x6.3
5. WE RESERVE THE RIGHT TO
(DRILLING AND TAPPING BY (BY OTHERS) MANUFACTURE IN ACCORDANCE TO OUR
UNDERSTANDING OF THE DESIGN INTENT
OTHERS) AND SPECIFICATION REQUIREMENTS AND
WILL NOT BE PRODUCING FULL SIZE
SAMPLES FOR EACH PIECE - SKETCH
DETAILS, FINISH SAMPLES AND DRAWINGS
ONLY WILL BE SUBMITTED FOR APPROVAL.

REQUEST FOR INFORMATION (RFI)


1.

2.

Approval Stamp
SS EYE NUT WELDED TO PLATE 80x80MM SS SQUARE TUBE WINCH CODE A APPROVED

SUPPORT BRACKET; FINISH TO MATCH Work can proceed

CODE B APPROVED WITH COMMENTS


STRUCTURAL BEAM Work can proceed incorporating the
comments
CODE C APPROVED WITH COMMENTS
Work can proceed incorporating the
SS 600x600MMx8MM THK SUPPORT comments; revise and re-submit
CODE D NOT APPROVED

SS SHACKLE - SCREW PIN PLATE; FINISH TO MATCH STRUCTURAL Re-submit


Designer Review
BEAM Signed

ALUMINIUM SQUARE TUBE FRAME FOR 4 x SUPER HEAVY DUTY


Contractor Review

Signed
PERFORATED PLATE; FINISH TO MATCH MOTORIZED WINCH WITH Reviewed for By (Name) Date
STRUCTURAL BEAM 200-500KG CAPACITY Architectural
Structural
Mechanical
Electrical
Other

0 04 MAR 19 FOR APPROVAL JBC

Rev Date Description Draw App.


REVISION SCHEDULE

Project:
8MM THK PERFORATED 320 x STRING OF
ALUMINIUM IN BRASS FINISH ACRYLIC AGORA MALL
STARLETS
Client:

Project Consultant:

Interior Consultant:

Sub Contractor:

Blow-up Details Drawing Title

ILLUMINATED HANGING STARLETS


DETAILS - VSI03 (SKYLIGHT 2)

Location
-----
Quantity Weight
1 SET ---
Sheet Original Scale Size
3 OF 3 1:80 A3
Drawn Checked Autorized
JOJE VSP TL
Date: Date: Date:
04 MAR 19 ----- -----
Drawing Number Rev

TLX-AM-IHS-VSI03 00

You might also like