160 54-PW3

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

Supersedes: 160.54-PW3 (399) Form 160.

54-PW3 (300)

WIRING DIAGRAM, MILLENNIUM®


MODEL YK (STYLE E) LIQUID CHILLERS
PRODUCT DRAWING
OPTIVIEW CONTROL CENTER
YORK INTERNATIONAL CORPORATION
P.O. Box 1592, York, PA 17405
WITH VARIABLE SPEED DRIVE
CONTRACTOR _______________________ PURCHASER ____________________________________________
ORDER NO. __________________________ JOB NAME _______________________________________________
YORK CONTRACT NO. _________________ LOCATION _______________________________________________
YORK ORDER NO. ____________________ ENGINEER ______________________________________________

REFERENCE DATE ________ APPROVAL DATE ________ CONSTRUCTION DATE ________

JOB DATA:

CHILLER MODEL NO. YK ________________________________________________________


NO. OF UNITS _____________
COMPRESSOR MOTOR ______________ VOLTS, 3-PHASE, _____________ Hz
OIL PUMP MOTOR _____________ VOLTS, 3-PHASE, _____________ Hz, _____________FLA

REMARKS:
2
DWG. 035-15193 (REV. C)
ELEMENTARY DIAGRAM

YORK INTERNATIONAL
FORM 160.54-PW3 FORM 160.54-PW3

LD05498
YORK INTERNATIONAL 3 YORK INTERNATIONAL 3A
FORM 160.54-PW3

ELEMENTARY DIAGRAM (Cont’d)

YORK INTERNATIONAL 3B 4 YORK INTERNATIONAL


FORM 160.54-PW3

LD05493

YORK INTERNATIONAL 5
FORM 160.54-PW3

TIMING DIAGRAM

LD05489

** This function is not for all shutdowns. See Operations Manual, Form 160.54-O1.

NOTES:
1. This wiring diagram describes the standard electronic 7. Device contact rating to be 5 milliamperes at 115 Volts
control scheme for use with a YORK Variable Speed A.C.
Drive. For details of standard modifications, refer to Prod- 8. Contact rating is 5A resistive @ 120 volts A.C. or 240
uct Form 160.54-PW7. volts A.C.
2. Field wiring to be in accordance with the National Elec- 9. _____________
trical Code as well as all other applicable codes and 10. For wiring diagram of Variable Speed Drive, refer to
specifications. See Product Form 160.54-PW6 for field Product Form 160.49-PW9.
wiring connections.
11. _____________
3. Numbers along the left side of diagram are line identifica-
12. Stop contact on V.S.D. Logic Board is set to trip at 105%
tion numbers. The numbers along the right side indicate
FLA.
the line number location of relay contacts. An underlined
contact location signifies a normally closed contact. 13. Contact rating is 5 Amps resistive @ 250 volts A.C. and
30 volts D.C., 2 Amp inductive (.4 PF) @ 250 Volts A.C.
4. Main control panel Class 1 field wiring terminal connec-
and 30 Volts D.C.
tion points are indicated by numbers within a rectangle,
i.e. 15 . Main control panel factory wiring terminal con- 14. Field connected control power supply is not required,
nection points are indicated by numbers within a triangle, as control transformer is supplied on the VSD.
i.e. 5 . Component terminal markings are indicated by 15. _____________
numbers within a circle, i.e. C1 . Numbers adjacent to 16. Each 115VAC field-connected inductive load: i.e. relay
circuit lines are the circuit identification numbers. coil, motor starter coil, etc., shall have a transient sup-
5. To cycle unit on and off automatically with contacts other pressor wired in parallel with its coil, physically located
than those shown, install a cycling device between ter- at the coil. Spare transient suppressors and control
minals 1 & 13 (line 37) (see note 7). If a cycling device circuit fuses are supplied in a bag attached to green
is installed, jumper must be removed between termi- ground screw in lower left corner of control panel.
nals 1 & 13 . 17. For units with Flash Miniature Card Software, Version
6. To stop unit and not permit it to start again, install a stop C.MLM.01.00 through C.MLM.01.03, the condenser
device between terminals 1 & 8 (Line 33) (see note 7). water pump should be wired to terminal 164 of TB2
A remote start - S33P switch may be connected to termi- instead of terminal 151, and the wire from terminal 22
nals 1 , 7 & 8 (Lines 32 & 33) (see note 7). Remote of TB5 to terminal 150 of TB2 shall not be installed. For
start-stop switch (Line 32) is operative only in the “re- software version C.MLM.01.04 and higher, the con-
mote” operating mode. denser pump connection should be as shown in the
figure.

YORK INTERNATIONAL 5A
FORM 160.54-PW3

LEGEND

LD05492

YORK INTERNATIONAL 5B 6
CONNECTION DIAGRAM

6 YORK INTERNATIONAL
FORM 160.54-PW3

LD05495

YORK INTERNATIONAL 7
CONNECTION DIAGRAM (Cont’d)

8 YORK INTERNATIONAL
FORM 160.54-PW3

LD05496

YORK INTERNATIONAL 9
WIRING FOR 230V AND 460V UNITS

LD05497

10 YORK INTERNATIONAL
FORM 160.54-PW3

WIRING FOR 346V AND 600V UNITS

LD05498

OIL PUMP MOTOR OIL PUMP FUSING


FULL DUAL
VOLTS-PH-HZ LOAD ELEMENT
AMPS FUSE SIZE*
440-3-60 3.5 7
460-3-60 3.3 7
480-3-60 3.2 7
* Oil pump motor supply fuses located in Variable Speed Drive.

YORK INTERNATIONAL 11
12 YORK INTERNATIONAL
FORM 160.54-PW3

LD05491

YORK INTERNATIONAL 13
INSIDE VIEW OF FRONT DOOR

LD05494

14 YORK INTERNATIONAL
FORM 160.54-PW3

PRESSURE TEMPERATURE CHART

LD05490

YORK INTERNATIONAL 15
Proud Sponsor
of the 2000
U.S. Olympic Team

36USC380

P.O. Box 1592, York, Pennsylvania USA 17405-1592 (717) 771-7890 Subject to change without notice. Printed in USA
Copyright © by York International Corporation 2000 www.york.com ALL RIGHTS RESERVED
Form 160.54-PW3 (300)
Supersedes: 160.54-PW3 (399)

You might also like