Professional Documents
Culture Documents
Glass Check
Glass Check
52 mm
FT glass)
NFL1 NFL2 GTF1 GTF2 LS1 LS2 LR1 KPa LR2 KPa Final Load
( NON ( NON ( GLASS (GLASS (LOAD (LOAD (LOAD LOAD resistance
FACTORED FACTORED TYPE TYPE SHARING SHARING CAPACITY- CAPACITY- (LR) Value-
LOAD FOR LOAD FOR FACTOR- FACTOR- FACTOR- FACTOR- LITE01) LITE02) KPa
LITE 01) LITE 02) LITE01) LITE 02) LITE 01) LITE02) =NFL1xGTF1xLS1 NFL2xGTF2xLS2
.875 1.125 2.85 2.85 3.37 1.42 8.07 Kpa 4.55Kpa 4.55Kpa
Actual Wind load =1.09 Kpa < 4.55 Kpa, hence safe
Load factor for outer glass
Deflection corresponding to Load x Area2 -7.06 , from Fig- A-17, ASTM E-1300
Deflection for the outr lite glass = 8mm
Maximum allowable deflection( ref- AS 1288) = Length of shorter span/60 = 1221/60= 20 mm > actual
deflection. Hence safe
Deflection calculation for outer glass
Load factor for inner glass
Deflection corresponding to Load x Area2(16.78) and Aspect ratio 3.17 , from Fig- A-17, ASTM E-
1300 =9.5 mm
Maximum allowable deflection( ref- AS 1288) = Length of shorter span/60 = 1221/60= 20.35 mm
Actual deflection < allowable deflection, hence Safe
Recommended to use 8mm Fully tempered +16mm Airspace +8mm Fully Tempered glass