Professional Documents
Culture Documents
TCD 184 DS4
TCD 184 DS4
[Meaning] In case that the over-speed detected by slow down switch more than [Action to take]
3times due to bigger speed command value by normal speed pattern than
compulsive deceleration command value.
1. Check the error that is related speed control device
[Explanation] START 2. Check the SDS distance and its activated position.
NO
Running
YES NO
3. [attachment 3] refer to SDS standard distance table
NO SDS_FORCE_DEC_INIT
High speed mode && SDS operated 1) Compare the each SDS distance and SPEC
YES
YES NO
Sds_Force_Dec_Count<3 2) Check the each SDS speed standard SPEC data
Compulsive deceleration speed
pattern made. YES
Sds_Force_Dec_Count += 1
NO Current speed value >=
Compulsive deceleration speed value
YES
END
[SDS Activating Position]
Speed(m/min), Distance(mm) Application ●
Speed SDS NO Applied 7 6 5 4 3 2 1
Installation/Position Quantity 36,100 27,600 20,300 14,000 11,350 8,900 6,850 5,050 2,700 2,700 1,400 1,400 400
Allow able Error 700 500 400 200 150 100 70 70 50 50 20 20 5
480 7 ● ● ● ● ● ● ●
420 7 ● ● ● ● ● ● ●
360 6 ● ● ● ● ● ●
300 6 ● ● ● ● ● ●
270 5 ● ● ● ● ●
240 5 ● ● ● ● ●
210 4 ● ● ● ●
180 4 ● ● ● ●
150 3 ● ● ●
120 3 ● ● ●
105 2 ● ●
90 2 ● ●