Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

MAIN : 4 pcs. - 16 mmØ , 2pcs.

- 12 mmØ
(FROM FOUNDATION TO ROOF BEAM)
A B C D
TIES : 10 mmØ LAT 50 , 8 @ 75 ,
REST @ 150 mm O.C. CONVERSELY
12350 150
USE :
4350 3650 4350 FFL 100 mm THK. CHB w/
WF WF
NGL
TB
GRAVEL BED WALL 10 mmØ VERT. & HOR. BARS
VERT. BARS @ 800 mm O.C.
HOR. BARS @ EVERY 3 LAYERS
WF

FFL
1350

WF

WF

WF

WF

RAMP
1 C1 C1-F1 GRAVEL BED NGL
F1 FTB FTB C1-F1 FTB C1-F1
WF

USE: 8 - 16mmØ (TOP)


FTB
4000

FTB

WF USE: 8 - 16mmØ
(BOTTOM) 70 70
WF

USE :
1200 100mm THK WELL 400
C1 COMPACTED 10 mmØ MAIN BARS
8000

2 GRAVEL BEDDING @ 200 mm O.C.


F1 WF WF 3 - 12 mmØ
300
F1 TEMP. BARS
FTB

FTB
WF
4000

USE: 8pcs. - 16mm Ø (TOP)


8pcs. - 16mm Ø (BOTTOM)
C1
C1-F1 C1-F1 C1-F1 C1-F1
3 WF
FTB FTB FTB
1500
1500

70 70
WF 450
1200
WF WF WF
COLUMN LAY-OUT
SCALE 1:100mts. DETAILS OF FOOTING, COLUMN & WALL FOOTING
SCALE 1:25mts.
SCHEDULE OF COL. SCHEDULE OF FOOTINGS
C-1

GRD. FLOOR TO ROOF DECK LEVEL


SIZE (m) BOTTOM BARS
THK DEPTH OF
MARK
(mm) WIDTH LENGTH BAR 'S' BAR 'L' EXCAVATION
F-1 300 1.20 1.20 8 - 16mmØ 8 - 16mmØ 1500
SIZE : 300 mm x 300 mm
VERT. BARS : 4- 16mm Ø
VERT. BARS : 2- 12mm Ø
TIES : 1 - 10 mm / SETS
SPACING OF LATERAL TIES:
1@50mm., 8@75mm.,
REST @ 150mm O.C.
Republic of the Philippines PREPARED BY: RECOMMENDING APPROVAL: NOTED BY: APPROVED BY: SHEET CONTENT: SHEET NO.
DEPARTMENT OF SOCIAL WELFARE & DEVELOPMENT
KALAHI- CIDSS: NCDDP Additional Financing
Construction of Quarantine Facility cum Evacuation REXTER S. PANGANIBAN ENGR. ROSENDO E. VELASCO ENGR. RAYMOND B. LIBARRA AS SHOWN CE- 8
Center and Purchase of Medical Supply and Equipment Technical Facilitator Municipal Engineer PDO IV for Infrastructure BDC TWG- Chairperson
Location: Brgy. Rumbang, Rizal, Occidental, Mindoro NOTE: All units are in meters unless otherwise stated