EFFICIENCY IS...
SAVING AND QUALITY OF LIFE
AIR TO WATER

HEAT PUMP
TECHNOLOGY

Heat pump commercial uses a thermodynamic cycle to heat the


water through the air sucked by the thermal group inverting the heat
natural flow. A refrigerant fluid (R417A),
through status changes, compression and expansion cycles, with-
draws the heat in the air at low temperature and gives it to domestic
water at a higher temperature. This is the reverse mechanism to the
one used in refrigerators.
The product electric consumption is only the one necessary to let
the fan (that captures the air) and the compressor (that allows the
refrigerant fluid to circulate in the system) work.

THERMODYNAMIC CYCLE
B
A-B External air is aspirated inside the heat pump compressor
thanks to a fan; when passing through the fins of the
evaporator, the air gives its heat and lose 10°C approx. heated water
Finally it is expelled.
to storage tank
fan
1 -2 The refrigerant fluid goes through the evaporator
and absorbs the heat given by the air.During this 2 3
process it changes its physical status and evaporate,
keeping temperature and pressure almost constant.
(10°C ; 5 bar).
evaporator condenser

2 - 3 The refrigerant fluid crosses the compressor


and experiences a pressure rising which involves an
increase of temperature. At the end of the process
the fluid is overheated vapor and its temperature and 1 4
pressure are 70°C and 20 bar respectively.
air* cold water from
3 - 4 Within the condenser, the refrigerant fluid gives its storage tank
heat to the water which warms up. By doing this, A
the refrigerant condensate at constant pressure (20
bar) and then experiences a significant reduction thermal Heat exchanger
expansion valve tube
of temperature. (70 –>40°C).

4 - 1 The refrigerant fluid passes through the expansion


valve, suddenly loose both pressure and temperature heat generated by electricity
and partially evaporate thus returning to the initia heat generated by renewable source
conditions of temperature and pressure. (40–>10°C; 5 l
bar). The thermodynamical cycle can now start over.

*Air heat energy resource can be obtained from Sun, Burning, Human/Animal, Vehicle exhaust, Industrial waste gas, etc
4/
HEAT PUMP RANGE
AIR TO WATER WATER TO WATER SWIMMING POOL

AR-6PM AR-40WTP AR-6SM

AR-10PM AR-80WTP AR-8SM

AR-17PTP AR-160WTP AR-12SM

AR-35PTP AR-20STP

AR-80PTP AR-50STP

AR-120PTP
/5
AIR TO WATER

TECHNICAL DATA AR-6PM AR-10PM AR-17PTP AR-35PTP AR-80PTP AR-120PTP

Voltage [V] 220 220 380 380 380 380


Phase Single phase Single phase Three phase Three phase Three phase Three phase
Frequency [Hz] 50 50 50 50 50 50
Heating capacity* [kW] 5,80 11,20 21,70 45,30 85 127
Rated power input* [kW] 1,36 2,83 5,31 11,27 19,7 29,5
Maximum current [A] 9 20 14 29 49 73.5
Heating water capacity [L/H] 124 240 465 970 2435 3638
COP* 4,26 3,96 4.09 4,02 4,3 4,3
Refrigerant R417 A R417 A R417 A R417 A R410 A R410 A
Refrigerant charge [gram] 1200 2100 3900 3700x2 3700x2 3700x2
Compressor
Type Rotary Rotary Rotary Rotary Scroll Scroll
Brand Highly Highly Highly Highly Sanyo Sanyo
Quantity 1 1 1 2 4 6
Condenser Tube in tube Tube in tube Tube in tube Tube in tube Tube in tube Tube in tube
Circulation pump Grundfos Grundfos - - - -
Rated water flow rate [m³/h] 1,6 2,00 4,00 8,00 16 24
Pressure Drop [KPa] 40 45 60 75 75 100
Circulation pump pressure head [m] 2,5 3,5 - - - -
Max. water temperature [C] 60 60 60 60 60 60
Operation temp. range [C] -10 ~ 45 -10 ~ 45 -10 ~ 45 -10 ~ 45 -10 ~ 45 -10 ~ 45
Noise [dB/(A)] ”56 ”58 ”60 ”62 ”64 ”65
Connection [inch] G3/4” G1” G1” G1-1/4” G2” G2-1/2”
Weight [Kg] 65 84 160 290 633 893
Index protection IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
Insulation class 1 1 1 1 1 1
Dimension [mm] 835x320x870 1200x440x870 830x850x1120 1230x1040x1420 2200x1135x2080 2400x1300x2150

*Heating by Ambient temp.(DB/WB) : 30℃ and Water temp.(in /out): 25℃/55℃;

6/
AIR TO WATER

DIMENSION AR-6PM

G3/4”

G3/4”

80

870
663

4-10x18

295
320
285
480
835

DIMENSION AR-10PM

G 1” 83
870
812

G 1”
123

162 4-10×20
390
420
440

700
1200

/7
DIMENSION AR-17PTP
5 5

4 4
6

1120
3
3

250

2
1 2
150

117.5

Ø700

1.Cable wiring.
2.Heating water input.
3.Heating water output.
4.High/Low pressure gauge.
850
820

780

5.Air output.
6.Wiring box.

460
800
830

DIMENSION AR-35PTP
4

5
1420

90
1256

2
250

1
6
134

970
1040

1. Heating water input Ø900

2. Heating water output


3. High/Low pressure gauge
4. Air output
1040
1010
970

5. Wiring box
6. Cable wiring

760
1200
1230

8/
DIMENSION AR-80PTP

5 5

1920 2120
1 406
3 3
2 328

4 188
850 850
50 1177
2400 1247

1.Heating water output


2.Heating water input.
1095 1135 3.High/Low pressure gauge.
4.Cable wiring.
5.Air output.

DIMENSION AR-120PTP
2080
1903

2.5 Flang 234±10

Ø145
261±10

Lifting hole

4- Ø 30
69±20 850 850 134±10 280 ±10
2396 1350±10

1460±10 Fastern
hole
1260

1412±10
1300

/9
WATER TO WATER

TECHNICAL DATA AR-40WTP AR-80WTP AR-160WTP

Voltage [V] 380 380 380


Phase Three phase Three phase Three phase
Frequency [Hz] 50 50 50
Heating capacity* [kW] 42 80 160
Rated power input* [kW] 8,9 17 34
Maximum current [A] 25 49 98
Heating water capacity [L/H] 903 1720 3440
COP* 4,7 4,7 4,7
Refrigerant R410a R410a R410a
Compressor
Type Scroll Scroll Scroll
Brand Sanyo Sanyo Sanyo
Quantity 2 4 8
Condenser Tube in tube Tube in tube Tube in tube
Circulation pump - - -
Rated hot water flow rate [m³/h] 8 16 32
Rated water source flow rate [m³/h] 6,4 12,8 25,6
Pressure Drop / Heating side [KPa] 65 110 140
Pressure Drop / Source side [KPa] 50 70 100
Circulation pump pressure head [m] - - -
Max. water temperature [C] 60 60 60
Water source temp. range [C] -10 ~ 35 -10 ~ 35 -10 ~ 35
Ground source temp. range [C] 7 ~ 35 7 ~ 35 7 ~ 35
Noise [dB/(A)] ”55 ”55 ”55
Connection [inch] G1-1/4” G2” G3”
Weight [Kg] 250 500 920
Index protection IPX4 IPX4 IPX4
Dimension [mm] 970x800x1387 2000x1197x1440 2396x2006x1721

*Heating by Ambient temp.(DB/WB) : 15℃ and Water temp.(in /out): 15℃/55℃;

10 /
WATER TO WATER

DIMENSION AR-40WTP

407
1387

407
148.3
800

547

900

940

970
DIMENSION AR-80WTP - AR-160WTP

Tampak Samping (AR-160WTP)


Tampak Depan Tampak Samping (AR-80WTP)
333

458
312

356
622
314

1721
500
501

188
441
312
187

326 605
1290 (AR-80WTP)
214

1290 (AR-160WTP)
2000 (AR-80WTP)
2396 (AR-160WTP)

Tampak Atas (AR-160WTP) Tampak Atas (AR-80WTP)


1060
1096
1197
2006
1900

1448

/ 11
SWIMMING POOL HEAT PUMPS

TECHNICAL DATA AR-6SM AR-8SM AR-12SM AR-20STP AR-50STP

Voltage [V] 220 220 220 380 380


Phase Single phase Single phase Single phase Three phase Three phase
Frequency [Hz] 50 50 50 50 50
Heating capacity* [kW] 5,5 7,6 12,5 22 49
Rated power input* [kW] 1,1 1,5 2,4 4,4 9,6
Maximum current [A] 7 10 14 15 30
COP* 5,2 5,2 5,2 5,2 5,25
Refrigerant R410a R410a R410a R410a R410a
Compressor
Type Rotary Rotary Rotary Scroll Scroll
Brand Panasonic Panasonic Panasonic Sanyo Sanyo
Condenser Titanium Titanium Titanium Titanium Titanium
Rated water flow rate [m³/h] 2 3 3 9 15
Pressure Drop [KPa] 1,5 4 4 10 25
Max. water temperature [C] 45 45 45 45 45
Operation temp. range [C] -10 ~ 45 -10 ~ 45 -10 ~ 45 -10 ~ 45 -10 ~ 45
Noise [dB/(A)] ”48 ”48 ”48 ”45 ”60
Connection [inch] G1-1/2” G1-1/2” G1-1/2” G1-1/2” G2”
Weight [Kg] 58 67 67 110 290
Index protection IPX4 IPX4 IPX4 IPX4 IPX4
Dimension [mm] 970x800x1387 970x800x1387 970x800x1387 1345x350x1265 1200x970x1425

*Heating by Ambient temp.(DB/WB) : 15℃ and Water temp.(in /out): 15℃/55℃;

12 /
SWIMMING POOL HEAT PUMPS

DIMENSION AR-6SM / AR-8SM / AR-8SM

TAMPAK SAMPING AR-6-8 SM TAMPAK DEPAN AR-6-8 & 12 SM TAMPAK SAMPING AR-6-8 SM

G1-1/2"

620 (AR-6-8SM)
715 (AR-12SM)
A
270

2- Ø 30
45

4
117

117

47
G1-1/2"
195
A TAMPAK ATAS AR-6-8 & 12 SM

TAMPAK SAMPING AR-12 SM 4-10×15 (AR-6-8SM) TAMPAK SAMPING AR-12 SM


4-10×20 (AR-12SM)

305 (AR-6-8SM)

350 (AR-6-8SM)
330 (AR-6-8SM)

485 (AR-12SM)
425 (AR-12SM)

453 (AR-12SM)
320
45

650 (AR-6-8SM)
750 (AR-12SM)
1005 (AR-6-8SM)
130
130

1115 (AR-12SM)
50
275
A-A

DIMENSION AR-20STP / AR-50STP

TAMPAK SAMPING TAMPAK SAMPING


(AR-20STP) (AR-50STP)
1120 (AR-20STP)
1422 (AR-50STP)
400

180 (AR-50STP)
132 (AR-20STP)
181 (AR-50STP)

1040 (AR-50STP)

1010 (AR-50STP)

800 (AR-20STP)
966 (AR-50STP)
840 (AR-20STP)
870 (AR-20STP)

460 (AR-20STP)
760 (AR-50STP)

800 (AR-20STP)
760 (AR-50STP)

/ 13
INSTALLATION
GUIDE
INSTALLATION FOR
AR-6PM & AR-10PM

10

Hot water user


7
5
2 3

1 4 6

Cold water Supply

INSTALLATION FOR
AR-17PTP & AR-35PTP

5 10
2 3 Hot water user
1 4 6

9
8

Cold water Supply

Legenda:
1 Ball valve 6 Safety valve
2 Flow switch 7 Check valve
3 Thermometer 8 Y Strain
4 Drain & Filling valve 9 Pump
5 Pressure gauge

16 /
INSTALLATION
GUIDE
INSTALLATION FOR
AR-6SM & AR-20STP

Swimming pool

Filter

water
pump

Tap
water

Detergent
pool

Heat Pump
AR-20STP / AR-50STP

/ 17
SERVICES

Ariston focuses on four operational areas of critical importance to the overall TECHNICAL
efficiency of the company. TRAINING
And it does, to support its partners (wholesalers, installers, technical assistance TECHNICAL ADVICE
centers, designers, end users) and the sales network with an efficient, interac-
tive and flexible. PRE / POST SALE
CONSULTANCY ON
STANDARDS

Transmit correct information and useful is the first step to achieve a high
level of quality. In a business like that in which we operate, the technical
support is a prerequisite for delivering a good product.

Before and after the sale, we are present with a constant consultancy.
Because every technological system must lie at the root.

ARISTON WATER HEATER


CALL CENTRE
1500986

JARINGAN SERVICE TERSEBAR DI SELURUH INDONESIA


Jabodetabek Blitar Lampung Padang
Bandung Cirebon Makasar Palembang
Batam Cianjur Malang Purwokerto
Balikpapan Denpasar Madiun Samarinda
Banjarmasin Jambi Manado Pontianak
Banyuwangi Jember Medan Semarang
Bangka Kediri Pekanbaru Solo
Surabaya Tasikmalaya Yogyakarta
ARISTON OFFERS COMPLETE
CUSTOMER SATISFACTION

The Internet site provides operators within the sector with all the
information which are linked to the “product catalogue”, offering
individual details of technical features, exploded views and spare parts
lists, updates for operating booklets and instruction manuals.
It provides users with telephone numbers and addresses for the
relevant Assistance Centres and stockists in their local area.
ariston.com

SERVICE

The capillary network of Ariston Technical Assistance Centres has been


developed to cover the entire country, in order to guarantee
emergency and routine maintenance operations which demonstrate
efficiency and a high degree of professional preparation.

A group of experts also support our Customers in the constant updating


process relating to new products and technologies

/ 19
Ariston Thermo Group disclaims all responsibility for possible printing or transcription mistakes of this catalogue. Furthermore, it reserves the right to change, without notice, the specification and information of the products contained herein.
DESIGN IT ALIANO

ARISTON THERMO GROUP


Ariston Thermo SpA
Viale A. Merloni, 45 • 60044 Fabriano (AN) - ITALY
Fax: 0732 602416

PT. Ariston Thermo Indonesia


Dipo Business Centre, 15ʰ floor
Jl. Jend. Gatot Subrot Kav 51-52
Jakarta 10260 - Indonesia
ariston.com

You might also like