SERVICE REPORT

SO Number : 8500166633
Customer : PT ARUAN CIPTA ENERGI
Unit Model : D6R
Serial Number : TTT00306
Arrangement :
SMU Unit : 5902 HOURS
Date Service : 03 DESEMBER 2021
Location Service : PTP.P.PRESISI - LAUSIMEME
Inspector : ZENI EFENDI

PT Trakindo Utama
Medan Branch
Tel.: +62 61 7865311
Dear Bapak/Ibu ...,

On behalf of everyone at PT Trakindo Utama, we would like to thank you for trusting us to excel your
business. Our continuous faith in the excellence of our products and services, something we are
committed to and would never sacrifice, has led us to where we are today. It’s always a pleasure
serving you and we certainly look forward to doing that in the future.

There is always room for improvement, so if we can serve you better in anyway, please do inform us.
Your feedback is very important as we are constantly looking for ways to advance ourselves and our
customers forward.

Thank you very much.

Best regards,

(Signature)

Jonny Rezki
Servce Supv Medan

PT Trakindo Utama
Medan Branch
Tel.: +62 61 7865311
FRONT REAR

RIGHT LEFT

NAME PLATE HOURS METER UNIT

Service Meter Unit : 5902 Hours


Name Plate Machine # TTT00306

PT Trakindo Utama
Medan Branch
Tel.: +62 61 7865311
PT Trakindo Utama
Medan Branch
Tel.: +62 61 7865311
Sesuai dari Report Customer bahwa Machine mengalami Problem Tidak Bisa Maju dan
Mundur, saat dilakukan Download Product Status Report ditemukan beberapa Logged Code
Secara Electrical System yang Menyebabkan Problem tersebut :
• Steering Control Position Sensor 1 Voltage Below Normal
• Steering Control Position Sensor 2 Voltage Below Normal
• Parking Brake Solenoid Current Below Normal
• Brake Pressure Modulation Solenoid Current Below Normal
• Service Brake Pedal Position Sensor Voltage Below Normal

Dari Data Tersebut Menyebabkan Machine Mengalami Problem :


• Steering Machine Tidak Berfungsi
• Parking Brake Tidak Bisa di Realease

Berikut ini Hasil Test yang dilakukan Terhadap Komponen tersebut .

Steering Position Sensor Rusak pada ET Tool Signal Steering Position Sensor Tidak Bisa
terbaca Voltage Below Normal terbaca saat Steering digerakan

Service Brake Position Sensor Rusak pada ET Signal Service Brake Position Sensor terbaca
Tools terbaca Voltage Below Normal Kecil Sekali Saat Service Brake digerakan

PT Trakindo Utama
Medan Branch
Tel.: +62 61 7865311
.

Solenoid Parking Brake Current Below Normal Parking Brake Pressure Saat Parking Brake
Switch dalam Off 0 Psi – Spec 348 Psi
Brake System tidak bisa Realease dengan
Kondisi Tersebut

Berdasarkan hasil investigasi terhadap Problem tersebut maka direkomendasikan untuk


dilakukan Penggantian Komponen sebagai Berikut :
• Penggantian Control Steering karena mengalami Keausan
• Penggantian Steering Position Sensor
• Penggantian Service Brake Position Sensor
• Penggantian Solenoid Parking Brake
• Penggantian Solenoid Service Brake
• Reseal Brake Control Valve

Kebutuhan Parts untuk pekerjaan tersebut terlampir dalam Parts List

Demikianlah Laporan hasil Investigasi terhadap Problem pada Machine tersebut . Atas
kerjasama yang Baik saya ucapkan Terima Kasih .

Medan 03 Desember 2021

Zeni E

PT Trakindo Utama
Medan Branch
Tel.: +62 61 7865311
PT Trakindo Utama
Medan Branch
Tel.: +62 61 7865311
Branch Address

PT Trakindo Utama
Medan Branch
Tel.: +62 61 7865311