Download as pdf or txt
Download as pdf or txt
You are on page 1of 132

INSTRUCTION MANUAL

VHF/UHF FM TRANSCEIVER

iE91
FOREWORD FEATURES
Thank you for purchase of this fine Icom product. We under- ❍ DV mode (Digital voice + Low-speed data
stand you have a choice of many different radios in the mar- communication) operation is ready
ket place. Many hours of research and development went into – GPS receiver connection
the design of your IC-E91, following Icom’s philosophy of – Text message and call sign exchange
“technology first.”
(Optional UT-121 DIGITAL UNIT is required.)
The IC-E91 VHF/UHF FM TRANSCEIVER is designed with Icom’s
superior technology and craftsmanship combining traditional
❍ Simple band scope
analog technologies with the new digital technologies, Digital ❍ Dualwatch operation
Smart Technologies for Amateur Radio (D-STAR), for a bal- ❍ Optional PC remote control
anced packaged.
With proper care, this product should provide you with years
of trouble-free operation. We want to take a couple of mo- IMPORTANT
ments of your time to thank you for making your IC-E91 your
radio of choice, and hope you agree with Icom’s philosophy of READ ALL INSTRUCTIONS carefully and completely
“technology first.” before using the transceiver.

SAVE THIS INSTRUCTION MANUAL— This in-


EXPLICIT DEFINITIONS struction manual contains important operating instructions for
the IC-E91.
WORD DEFINITION
Personal injury, fire hazard or electric shock
R WARNING!
may occur.
CAUTION Equipment damage may occur.
Icom, Icom Inc. and the logo are registered trademarks of Icom
Recommended for optimum use. No risk of Incorporated (Japan) in the United States, the United Kingdom, Ger-
NOTE
personal injury, fire or electric shock. many, France, Spain, Russia and/or other countries.
i
PRECAUTIONS 1
2
RWARNING RF EXPOSURE! This device emits NEVER expose the transceiver to rain, snow or any liquids.
Radio Frequency (RF) energy. Caution should be observed The transceiver may be damaged. 3
when operating this device. If you have any questions re- NEVER operate or touch the transceiver with wet hands. 4
garding RF exposure and safety standards please refer to the This may result in an electric shock or damage the trans-
Federal Communications Commission Office of Engineering ceiver.
5
and Technology’s report on Evaluating Compliance with FCC 6
Guidelines for Human Radio Frequency Electromagnetic DO NOT operate the transceiver near unshielded electri-
Fields (OET Bulletin 65) cal blasting caps or in an explosive atmosphere. 7
RWARNING! NEVER hold the transceiver so that the DO NOT push the PTT when not actually desiring to transmit. 8
antenna is very close to, or touching exposed parts of the BE CAREFUL! The transceiver will become hot when op- 9
body, especially the face or eyes, while transmitting. The erating it continuously for long periods.
transceiver will perform best if the microphone is 5 to 10 cm
AVOID using or placing the transceiver in direct sunlight or 10
away from the lips and the transceiver is vertical.
in areas with temperatures below –20°C or above +60°C. 11
RWARNING! NEVER operate the transceiver with a Place the unit in a secure place to avoid inadvertent use by
earphone, headphones or other audio accessories at high 12
children.
volume levels. Hearing experts advise against continuous 13
high volume operation. If you experience a ringing in your AVOID the use of chemical agents such as benzine or al-
ears, reduce the volume level or discontinue use. cohol when cleaning, as they can damage the transceiver’s 14
surfaces.
RWARNING! NEVER operate the transceiver while 15
driving a vehicle. Safe driving requires your full attention—
anything less may result in an accident. 16
NEVER connect the transceiver to a power source of more 17
than 16 V DC. This will ruin the transceiver. 18
NEVER connect the transceiver to a power source using
19
reverse polarity. This will ruin the transceiver.
ii
TABLE OF CONTENTS
FOREWORD …………………………………………………………… i 5 BASIC OPERATION ……………………………………… 20–28
EXPLICIT DEFINITIONS ……………………………………………… i ■ Receiving ……………………………………………………… 20
FEATURES ……………………………………………………………… i ■ Setting audio volume ………………………………………… 20
IMPORTANT …………………………………………………………… i ■ Setting squelch level ………………………………………… 21
PRECAUTIONS ……………………………………………………… ii ■ Operating mode selection …………………………………… 21
TABLE OF CONTENTS ……………………………………………… iii ■ Monitor function ……………………………………………… 22
SUPPLIED ACCESSORIES ………………………………………… v ■ Attenuator function …………………………………………… 22
■ Band scope …………………………………………………… 23
1 ACCESSORY ATTACHMENT ………………………………… 1 ■ Transmitting …………………………………………………… 24
■ Antenna ………………………………………………………… 1 ■ Transmit power selection …………………………………… 24
■ Belt clip ………………………………………………………… 1 ■ Lock function ………………………………………………… 25
■ Handstrap ……………………………………………………… 1 ■ Dualwatch operation ………………………………………… 25
■ Battery pack …………………………………………………… 1 ■ TV channel operation ………………………………………… 28
2 PANEL DESCRIPTION ……………………………………… 2–7 6 REPEATER AND DUPLEX OPERATIONS ……………… 29–33
■ Front, top and side panels …………………………………… 2 ■ General ………………………………………………………… 29
■ Function display ……………………………………………… 6 ■ Accessing a repeater ………………………………………… 30
3 BATTERY CHARGING ……………………………………… 8–13 ■ Duplex operation ……………………………………………… 32
■ Caution ………………………………………………………… 8 ■ 1750 Hz tone ………………………………………………… 33
■ Regular charging ……………………………………………… 10 7 DV MODE OPERATION
■ Rapid charging ……………………………………………… 11 (Optional UT-121 is required) ……………………………… 34–63
■ Optional battery case ………………………………………… 12 ■ Digital mode operation ……………………………………… 34
■ Battery information …………………………………………… 12 ■ Call sign programming ……………………………………… 34
■ External DC power operation ……………………………… 13 ■ Digital voice mode operation ………………………………… 38
4 FREQUENCY AND CHANNEL SETTING ……………… 14–19 ■ About D-STAR system ……………………………………… 40
■ Main band selection ………………………………………… 14 ■ Digital repeater operation …………………………………… 41
■ Mode selection ……………………………………………… 15 ■ Received call sign …………………………………………… 46
■ Operating band selection …………………………………… 16 ■ Copying the call sign ………………………………………… 48
■ Setting a tuning step ………………………………………… 18 ■ Break-in communication …………………………………… 51
■ Setting a frequency …………………………………………… 18 ■ Message operation …………………………………………… 52
■ Automatic reply function ……………………………………… 54
iii
■ EMR communication ………………………………………… 56 11 MENU SCREEN OPERATION ………………………… 85–102
■ Low-speed data communication …………………………… 56 ■ General ………………………………………………………… 85
■ GPS operation ………………………………………………… 58 ■ MENU screen indication for B band ………………………… 86
■ Other functions for DV mode operation …………………… 62 ■ Menu list ……………………………………………………… 86
■ Items list ……………………………………………………… 86
8 MEMORY/CALL CHANNELS …………………………… 64–73 ■ Set mode items ……………………………………………… 88
■ General description ………………………………………… 64 ■ DV set mode items …………………………………………… 92
■ Selecting a memory channel ………………………………… 64 ■ Scan set mode items ………………………………………… 96
■ Selecting a call channel ……………………………………… 65 ■ DUP/TONE set mode items ………………………………… 97
■ Memory channel programming ……………………………… 66 ■ Display set mode items ……………………………………… 99
■ Memory bank setting ………………………………………… 67 ■ Sounds set mode items …………………………………… 102
■ Memory bank selection ……………………………………… 68
■ Programming memory/bank/scan name …………………… 69 12 OTHER FUNCTIONS …………………………………… 103–117
■ Selecting memory/bank name indication ………………… 70 ■ Programming a DTMF code ……………………………… 103
■ Copying memory/call contents ……………………………… 71 ■ Transmitting a DTMF code ………………………………… 104
■ Memory clearing ……………………………………………… 72 ■ Clearing a DTMF memory ………………………………… 105
■ Erasing/transferring bank contents ………………………… 73 ■ Confirming a DTMF memory ……………………………… 105
■ Setting DTMF transfer speed ……………………………… 106
9 SCAN OPERATION ………………………………………… 74–81 ■ Tone frequency and DTCS code ………………………… 106
■ Scan types …………………………………………………… 74 ■ Digital code and digital call sign setting ………………… 108
■ Full/band/programmed scan ………………………………… 75 ■ Tone/DTCS squelch ………………………………………… 110
■ Scan edges programming …………………………………… 76 ■ Digital code/digital call sign squelch ……………………… 110
■ Memory scan ………………………………………………… 77 ■ Pocket beep function ……………………………………… 111
■ Memory bank scan …………………………………………… 78 ■ DTCS polarity setting ……………………………………… 111
■ Skip channel/frequency setting ……………………………… 79 ■ Tone scan …………………………………………………… 112
■ Scan resume condition ……………………………………… 81 ■ Beep tones …………………………………………………… 113
10 PRIORITY WATCH ………………………………………… 82–84 ■ Dial speed acceleration …………………………………… 113
■ Priority watch types ………………………………………… 82 ■ Key lock effect ……………………………………………… 113
■ Priority watch operation ……………………………………… 83 ■ Power save ………………………………………………… 114
■ Auto power OFF …………………………………………… 114
■ Auto power ON ……………………………………………… 114

iv
■ Time-out timer ……………………………………………… 115
■ PTT lock ……………………………………………………… 115 SUPPLIED ACCESSORIES
■ [MIC/SP] jacks ……………………………………………… 115
■ Cloning function …………………………………………… 116
The following accessories are supplied with the transceiver.
■ Resetting …………………………………………………… 117
q Hand strap ………………………………………………… 1
13 TROUBLESHOOTING ………………………………………… 118 w Antenna …………………………………………………… 1
14 SPECIFICATIONS ……………………………………… 119–120 e Battery pack* ……………………………………………… 1
r Battery charger* …………………………………………… 1
15 OPTIONS ………………………………………………… 121–123
t Belt clip (with screws) ………………………………… 1 set
■ Optional UT-121 installation ……………………………… 122
■ Optional HM-75A REMOTE CONTROL MICROPHONE ……… 123 *Not supplied with some versions.

16 CE ………………………………………………………… 124–125
q w e r

v
ACCESSORY ATTACHMENT 1
■ Antenna ■ Handstrap 1
Insert the supplied antenna into the Slide the handstrap through the loop
antenna connector and screw down on the top of the belt clip as illustrated
Jack cover the antenna as shown at left. at left to facilitate carrying the
NEVER carry the transceiver by hold- transceiver.
ing the antenna.

KEEP the jack cover attached when


jack is not in use to protect the con-
nector from dust and moisture.
Handstrap
✔ For your information
Third-party antennas may increase transceiver perfor-
mance. An optional AD-92SMA ANTENNA CONNECTOR
ADAPTER is available to connect an antenna with a BNC
■ Battery pack
connector. Attach the Li-ion battery pack (BP-217) or battery case (BP-
216) as illustrated below.

■ Belt clip
• Charge the Li-ion battery pack before use. (pgs. 10, 11)
Battery pack/
Battery case
Supplied screws*
*NOTE:
USE the supplied screws q
only. Using screws lon-
ger than specified could
damage the transceiver. w

Latch
1
2 PANEL DESCRIPTION

■ Front, top and side panels


w TX/RX INDICATOR [TX/RX] (p. 24)
Lights green while receiving a signal or when the squelch
!7 is open; lights red while transmitting.
e PTT SWITCH [PTT] (p. 24)
!6 !4 Push and hold to transmit, release to receive.
q
!5 !3 r SQUELCH KEY [SQL]
➥ Push and hold to open the squelch temporarily and
monitor the operating frequency. (p. 22)
w ➥ While pushing and holding this key, rotate [DIAL] to ad-
Function display just the squelch level. (p. 21)
e
Internal microphone t MENU/LOCK KEY [MENU/LOCK]
r ➥ Push to toggle menu screen indication ON and OFF.
t Speaker (p. 85)
➥ Push and hold for 1 sec. to toggle the lock function ON
y !2
and OFF. (p. 25)
u
!1
!0 y POWER KEY [PWR]
i
o Push and hold for 1 sec. to turn the transceiver power ON
and OFF.
u MAIN/DUAL KEY [MAIN/DUAL]
q ANTENNA CONNECTOR (p. 1) ➥ Push to select the main band between A and B bands.
Connects the supplied antenna. (p. 26)
• An optional AD-92SMA adapter (p. 121) is available for connect- ➥ Push and hold for 1 sec. to toggle the dualwatch func-
ing an antenna with a BNC connector. tion ON and OFF. (p. 25)
i KEYPAD (pgs. 4, 5)
2
PANEL DESCRIPTION 2

o CALL/RX➝CS KEY [CALL]/[RX➝CS](CALL) !3 EXTERNAL DC IN JACK [DC IN]


➥ Push to select the call channel/TV channel. (p. 16) ➥ Connects the supplied wall charger, BC-167A/D, to
➥ During DV mode operation, push and hold for 1 sec. to charge the attached battery pack. (p. 10) 2
set the received call signs (station and repeaters) for op- ➥ Connect an external DC power supply through the op-
eration. (p. 47) tional CP-19R or OPC-254L for external DC operation.
➥ Enters or sends the DTMF code “C.” (pgs. 103, 104) (p. 13)
!0 MEMORY/SELECT MEMORY WRITE KEY !4 DATA JACK [DATA]
[MR]/[S.MW](MR) Connects a PC through the optional data communication
➥ Push to select memory mode. (p. 15) cable, OPC-1529R, for low-speed data communication or
➥ During memory mode operation, push to toggle be- control the transceiver remotely using the optional RS-91
tween memory and memory bank mode. (p. 68) (OPC-1529R is supplied). (p. 56)
➥ Push and hold for 1 sec. to enter select memory write
mode. (p. 64) !5 VOLUME CONTROL [VOL]
➥ Enters or sends the DTMF code “B.” (pgs. 103, 104) Rotate to adjust the audio output level. (p. 20)

!1 VFO/MHz KEY [VFO]/[MHz](VFO) !6 CONTROL DIAL [DIAL]


➥ Push to toggle select VFO mode. (p. 15) ➥ Rotate to tune the operating frequency. (p. 18)
➥ During VFO mode operation, push and hold for 1 sec. to ➥ During memory mode, rotate to select the memory
select and toggle 1 MHz and 10 MHz tuning steps channel. (pgs. 15, 64)
(p. 18) ➥ While pushing and holding [BAND], selects the operat-
➥ Enters or sends the DTMF code “A.” (pgs. 103, 104) ing band in VFO mode. (p. 18)
➥ While scanning, changes the scanning direction. (p. 75)
!2 BAND KEY [BAND]
➥ While pushing and holding [SQL], sets the squelch
➥ During VFO mode operation, push to select an operat-
level. (p. 21)
ing frequency band. (pgs. 16, 17)
➥ While pushing and holding [BAND], selects the pro-
➥ During memory bank mode, push to select a memory
grammed bank in memory mode. (p. 68)
bank. (p. 68)
➥ Enters or sends the DTMF code “D.” (pgs. 103, 104) !7 EXTERNAL SPEAKER/MICROPHONE JACK [MIC/SP]
Connect an optional speaker-microphone or headset, if de-
sired.
See page 121 for a list of available options.
3
2 PANEL DESCRIPTION

D KEYPAD
KEY Pushed momentarily Pushed and held for 1 sec.
• Inputs digit ‘1’ for frequency input, memory channel selection, • Displays the simple band scope for a single sweep. (p. 23)
etc.
• While pushing [PTT], this key sends the DTMF code “1.”
• Inputs digit ‘2’ for frequency input, memory channel selection, • Starts a scan. (p. 75)
etc.
• While pushing [PTT], this key sends the DTMF code “2.”
• Inputs digit ‘3’ for frequency input, memory channel selection, • Toggles the transmit output power between high and low. (p. 24)
etc. - “LOW” appears when low power is selected.
• While pushing [PTT], this key sends the DTMF code “3.” - While pushing and holding this key, with [DIAL] rotation selects
the output power.
• Inputs digit ‘4’ for frequency input, memory channel selection, • Activates the following duplex functions in order.
etc. - Minus duplex operation— “–DUP” appears.
• While pushing [PTT], this key sends the DTMF code “4.” - Plus duplex operation— “+DUP” appears.
- Simplex operation— no duplex indicator appears.
- While pushing and holding this key, with [DIAL] rotation selects
the duplex function.
• Inputs digit ‘5’ for frequency input, memory channel selection, • Turn the frequency skip function ON and OFF in VFO mode, or
etc. set the memory channel as the following skip channel in memory
• While pushing [PTT], this key sends the DTMF code “5.” mode in order (p. 79).
- Skip channel— “SKIP” appears.
- Frequency skip channel— “PSKIP” appears.
- Non-skip channel— no skip indicator appears.
• Inputs digit ‘6’ for frequency input, memory channel selection, • Turn the memory name or bank name indication ON and OFF.
etc. (p. 70)
• While pushing [PTT], this key sends the DTMF code “6.”

4
PANEL DESCRIPTION 2

KEY Pushed momentarily Pushed and held for 1 sec.


2
• Inputs digit ‘7’ for frequency input, memory channel selection, • During FM/FM-N mode operation, selects repeater tone, tone
etc. squelch, DTCS squelch and no tone operation in sequence.
• While pushing [PTT], this key sends the DTMF code “7.” (p. 110)
• During DV mode operation, selects digital call sign, digital code
and no tone operation in sequence. (p. 110)
• Inputs digit ‘8’ for frequency input, memory channel selection, • Selects tuning step selection. (p. 18)
etc.
• While pushing [PTT], this key sends the DTMF code “8.”
• Inputs digit ‘9’ for frequency input, memory channel selection, • During FM/FM-N mode operation, starts tone scan function.
etc. (p. 112)
• While pushing [PTT], this key sends the DTMF code “9.” • During DV mode operation, selects break-in operation mode.
(p. 51)
• Inputs digit ‘0’ for frequency input, memory channel selection, • During DV mode operation, set “CQCQCQ” for station’s call sign
etc. for operation.
• While pushing [PTT], this key sends the DTMF code “0.”
• Inputs MHz digit for frequency input. • Select DTMF memory mode. (p. 103)
• While pushing [PTT], this key sends the DTMF code “F (#).” • During DV mode operation, to turn EMR mode operation ON,
keep pushing and holding until 3 short and 1 long beeps are
emitted. (p. 56)
• During DV mode operation, selects the record track for voice • Selects the operating mode.
memory. (p. 62)
• While pushing [PTT], this key sends the DTMF code “E (✱).”

5
2 PANEL DESCRIPTION

■ Function display
• Single band indication q BATTERY INDICATOR (pgs. 10, 12)
q w e r t y
➥“ ” (battery indicators) appear when the Li-ion bat-
tery pack is attached.
-DUP DSQL ➥ “ ” appears when the battery pack must be charged.
!7 DV PRIO EMR u ➥ The indicators show “ ,” “ ” and “ ” in se-
!6 B 439 706 25 i
quence while charging the attached battery pack.
w DUPLEX INDICATORS (p. 29)
!5 MemoName PSKIP o “+DUP” appears when plus duplex, “–DUP” appears when
!4 µ 000 !0 minus duplex is selected.
!3 LOW
ATT e PRIORITY WATCH INDICATOR (p. 83)
Appears when priority watch is in use.
!2 !1
r TONE INDICATORS
• Dualwatch indication • While operating in FM mode;
!6 i e o
➥ “TONE” appears while the subaudible tone encoder is
PS in use. (pgs. 29, 106)
25 PRIO t ➥ “TSQL” appears while the tone squelch function is in
88 100 µ 000 !0 use. (p. 110)
!7
q ➥ “DTCS” appears while the DTCS squelch function is in
use. (p. 110)
y !1 !4 !8 ➥ “S” appears with the “TSQL” or “DTCS” indicator
!6 w r e o while the pocket beep function (with CTCSS or DTCS) is
-DUP DTCS PS in use. (p. 111)
75 PRIO • While operating in DV mode;
i 439 706 µ 000 !0 ➥ “DSQL” appears while the call sign squelch function is
!7
!3 in use. (p. 110)
➥ “CSQL” appears while the digital code squelch function
!2 !1 !4 !8 is in use. (p. 110)
6
PANEL DESCRIPTION 2

➥ “S” appears with the “DSQL” or “CSQL” indicator !1 S/RF METER


while the pocket beep function (with digital call sign or dig- ➥ Shows the relative signal strength while receiving sig-
ital code squelch) is in use. (p. 111) nals. 2
➥ Shows the output power level while transmitting. (p. 24)
t KEY LOCK INDICATOR (pgs. 25, 113)
Appears when the key lock function is activated. !2 ATTENUATOR INDICATOR (p. 22)
Appears when the RF attenuator is in use.
y AUTO POWER OFF INDICATOR (p. 88)
Appears when the auto power OFF function is in use. !3 LOW POWER INDICATOR (p. 24)
➥ “LOW” appears when low power is selected.
u EMR MODE INDICATOR (p. 56)
➥ No indicator appears when high power is selected.
Appears when the EMR mode operation is selected.
!4 MEMORY INDICATOR (p. 64)
i FREQUENCY READOUT
Appears when memory mode is selected.
Displays a variety of information, such as operating fre-
quency, set mode contents, memory names. !5 NAME INDICATOR (p. 70)
• The decimal point blinks during scan. During memory mode operation, the programmed memory
or memory bank name is displayed.
o SKIP INDICATORS (pgs. 79, 80)
➥ “SKIP” appears when the selected memory channel is !6 MAIN BAND INDICATOR (p. 14)
set as a skip channel. Shows which operating band, “A” or “B,” is selected for the
➥ “P SKIP” appears when the displayed frequency is set main band.
as a skip frequency.
!7 OPERATING MODE INDICATOR (p. 21)
!0 MEMORY CHANNEL NUMBER INDICATOR Shows the selected operating mode.
➥ Shows the selected memory channel number. (pgs. 64, • DV, FM, FM-N, WFM and AM are available, depending on oper-
65) ating band.
➥ “C” appears when the call channel is selected. (pgs. 16,
!8 SIMPLE BAND SCOPE INDICATOR (p. 23)
65)
When the simple band scope function is in use, shows the
➥ “TV” appears when the TV channel is selected.
band conditions.
(pgs. 16, 28)

7
3 BATTERY CHARGING

■ Caution
Misuse of Lithium-ion batteries may result in the follow- • R DANGER! DO NOT expose the battery to rain, snow,
ing hazards: smoke, fire, or the battery may rupture. seawater, or any other liquids. Do not charge or use a wet
Misuse can also cause damage to the battery or degra- battery. If the battery gets wet, be sure to wipe it dry before
using. The battery is not waterproof.
dation of battery performance.
• R DANGER! NEVER incinerate an used battery pack since
internal battery gas may cause it to rupture, or may cause
• R DANGER! Use and charge only specified Icom battery an explosion.
packs with Icom radios. Only Icom battery packs are tested
• R DANGER! NEVER solder the battery terminals, or
and approved for use with Icom radios. Using third-party or
NEVER modify the battery pack. This may cause heat gen-
counterfeit battery packs may cause smoke, fire, or cause
eration, and the battery may burst, emit smoke or catch fire.
the battery to burst.
• R DANGER! Use the battery only with the transceiver for
which it is specified. Never use a battery with any other
D Battery caution
equipment, or for any purpose that is not specified in this in-
• R DANGER! DO NOT hammer or otherwise impact the bat- struction manual.
tery. Do not use the battery if it has been severely impacted
• R DANGER! If fluid from inside the battery gets in your
or dropped, or if the battery has been subjected to heavy
eyes, blindness can result. Rinse your eyes with clean
pressure. Battery damage may not be visible on the outside
water, without rubbing them, and see a doctor immediately.
of the case. Even if the surface of the battery does not show
cracks or any other damage, the cells inside the battery may • WARNING! Immediately stop using the battery if it emits an
rupture or catch fire. abnormal odor, heats up, or is discolored or deformed. If any
of these conditions occur, contact your Icom dealer or dis-
• R DANGER! NEVER use or leave battery pack in areas
tributor.
with temperatures above +60˚C. High temperature buildup
in the battery, such as could occur near fires or stoves, in- • WARNING! Immediately wash, using clean water, any part
side a sun heated car, or in direct sunlight may cause the of the body that comes into contact with fluid from inside the
battery to rupture or catch fire. Excessive temperatures may battery.
also degrade battery performance or shorten battery life.

8
BATTERY CHARGING 3

• WARNING! NEVER put the battery in a microwave oven, D Charging caution


high-pressure container, or in an induction heating cooker. • R DANGER! NEVER charge the battery pack in areas with 3
This could cause a fire, overheating, or cause the battery to extremely high temperatures, such as near fires or stoves,
rupture. inside a sun heated car, or in direct sunlight. In such envi-
• CAUTION! Always use the battery within the specified tem- ronments, the safety/protection circuit in the battery will acti-
perature range, –20˚C to +60˚C. Using the battery out of its vate, causing the battery to stop charging.
specified temperature range will reduce the battery’s perfor- • WARNING! DO NOT charge or leave the battery in the bat-
mance and battery life. tery charger beyond the specified time for charging. If the
• CAUTION! Shorter battery life could occur if the battery is battery is not completely charged by the specified time, stop
left fully charged, completely discharged, or in an excessive charging and remove the battery from the battery charger.
temperature environment (above +50˚C) for an extended Continuing to charge the battery beyond the specified time
period of time. If the battery must be left unused for a long limit may cause a fire, overheating, or the battery may rup-
time, it must be detached from the radio after discharging. ture.
You may use the battery until the battery indicator shows • WARNING! NEVER insert the transceiver (battery attached
half-capacity, then keep it safely in a cool dry place with the to the transceiver) into the charger if it is wet or soiled. This
temperature between –20˚C to +20˚C. could corrode the battery charger terminals or damage the
charger. The charger is not waterproof.
• CAUTION! DO NOT charge the battery outside of the spec-
ified temperature range: 0˚C to +35˚C. Icom recommends
charging the battery at +20˚C. The battery may heat up or
rupture if charged out of the specified temperature range.
Additionally, battery performance or battery life may be re-
duced.

9
3 BATTERY CHARGING

■ Regular charging
Prior to using the transceiver for the first time, the battery • BC-167A/D
pack must be fully charged for optimum life and operation. Transceiver

D Battery indicators
to AC outlet
The indicators show “ ,” “ ” and “ ” in sequence
while charging, and both indicators disappear when com- to
pletely charged. [DC IN] • CP-19R (Optional)
to cigarette lighter
D Charging note socket (12 V DC)

• Be sure to turn the transceiver power OFF.


Otherwise the battery pack will not be charged completely or takes
longer charging time periods. Turn power OFF while
• External DC power operation becomes possible when using charging the battery • OPC-254L (Optional)
an optional CP-19R or OPC-254L. The attached battery pack.
to 12 V DC
pack is also charged simultaneously, except during transmit. (power supply)
(see p. 11 for more details) • Charging time period:
Approx. 6 hours
• The external DC power supply voltage must be within Black: _
10–16 V to charge the battery pack and operation when
using an optional OPC-254L. White: +

10
BATTERY CHARGING 3

■ Rapid charging
The optional BC-139 provides rapid charging of the battery Transceiver
pack. (with battery pack)
Battery pack
3
• Charging period: 2.5 hours (with BP-217) Turn power OFF.

D Charging note to AC outlet


Check the
• Be sure to turn the transceiver power OFF. orientation.
Detach the battery pack from the transceiver then charge A
Adapter (supplied
the battery pack by itself, or charge the battery with regular
with BC-139)
charging when the transceiver power cannot be turned OFF.
Otherwise the battery pack will not be charged (charging indi- BC-123 Charging
cator on the BC-139 blinks orange). (supplied terminal
• The desktop charger, BC-139, can only be charged BP-217. with BC-139)
Other types of rechargeable battery, Ni-Cd or Ni-MH, can-
not be charged. to [AC ADAPTER] BC-139 (optional)
• If the charging indicator blinks orange, there may be a prob- Charging indicator Desktop charger
lem with the battery pack (or charger). Reinsert the battery Charging : Orange
pack or contact your dealer. Finished : Green
• The optional CP-19R and OPC-254L can be used instead
of the supplied AC adapter (BC-123). Connect one of these
to the [AC ADAPTER] jack in this case.

11
3 BATTERY CHARGING

■ Optional battery case ■ Battery information


➥ Install 2 R6 (AA) size alka- D Battery life
line batteries into the op-
The transceiver operates with the BP-217 as follows.
tional BP-216 BATTERY
However, when operating in DV mode, operating time may be
CASE.
• Be sure to observe the cor-
shortened by one-half hour.
rect polarity. • VHF band : Approx. 5 hours
• UHF band : Approx. 4.5 hours
(Tx: Rx: Stand-by=1: 1: 8)
A built-in step-up convertor in the BP-216 increases the
voltage to 5 V DC. Even when the transceiver power is OFF, a slight current
Approx. 100 mW of output power is possible with the BP- still flows in the circuits. Remove the battery pack or case
216 operation. Also, no transmit output power selection is from the transceiver when not using it for a long time. Oth-
available. erwise, the battery pack or installed batteries will become
exhausted.
Keep battery contacts clean. It’s a good idea to clean bat-
tery terminals once a week. D Battery indicator
The battery indicator, “ ,” appears only when the BP-217
D Battery information is attached to the transceiver.
The batteries may seem to have low capacity when used in
low temperatures such as –10°C or below. Keep the battery The battery indicator does not appear when turning power
case or pack warm in this case. ON after the charging is completed without disconnecting
the battery charger or external DC power.
D Battery replacement Indication Battery condition
When the batteries become exhausted, the function display The battery has ample capacity.
may blink or have a lower contrast. In these cases, replace
The battery is nearing exhaustion. Charging is neces-
all batteries with new, same brand, alkaline batteries.
sary.

12
BATTERY CHARGING 3

■ External DC power operation


An optional cigarette lighter cable CP-19R; for 12 V cigarette Transceiver
lighter socket) or external DC power cable (OPC-254L) can be
used for external power operation. • CP-19R (Optional)
3
to cigarette lighter
socket (12 V DC)
D Operating note to
• Power supply range is between 10.0–16.0 V DC. [DC IN]
NEVER CONNECT OVER 16 V DC directly into the [DC IN]
jack of the transceiver.
• BE SURE to use CP-19R or OPC-254L when connecting a
regulated 12 V DC power supply. • OPC-254L (Optional)
Use an external DC-DC converter to connect the transceiver
to 12 V DC
through optional CP-19R or OPC-254L to a 24 V DC power
(power supply)
source.
• The voltage of the external power supply must be within Black: _
10–16 V DC when using either CP-19R or OPC-254L, oth-
erwise, use the battery pack. White: +
• Up to 5 W (approx.) of maximum output power is provided
with the external DC power operation, however, when the
supplied voltage exceeds 14 V, the built-in protection circuit
activates to reduce the transmit output power to 0.5 W (ap-
prox.).
• Disconnect the power cables from the transceiver when not
using it. Otherwise, the vehicle battery will become ex-
hausted.
• The power save function is deactivated automatically during
external DC power operation.

13
New2001 New

4 FREQUENCY AND CHANNEL SETTING

■ Main band selection


The IC-E91 has two independent operating bands; A band D How to change the main band
and B band. A band can operate 0.495 MHz to 999.990
➥ Push [MAIN/DUAL] to toggle between A and B band.
MHz*, and B band can operate 118 MHz to 174 MHz* and
➥ Push and hold [MAIN/DUAL] for 1 sec. to turn the dual-
350 MHz to 470 MHz*.
watch operation ON and OFF.
*Some frequency ranges are blocked according to transceiver ver-
• While in dualwatch operation, the display indicates A band in the
sion. upper half and B band in the lower half.
NOTE: When in dualwatch mode, transmission is available ➥ During dualwatch operation, push [MAIN/DUAL] to select
from the MAIN band only. A band or B band as the main operating band alternately.

Single band operation Dualwatch operation


• Selecting A band • Selecting upper side as main band
+DUP DTCS +DUP DTCS W PS
FM PRIO WX EMR
145 000 25 µPRIO000
A
145 000 25
FM

MemoName P SKIP +DUP DTCS W PS

LOW
µ 000 430 00050 µPRIO000
EM

ATT FM
Push
Push Push

• Selecting B band for 1 sec. • Selecting lower side as main band


+DUP DTCS +DUP DTCS W PS
FM PRIO WX EMR
145 000 25 µPRIO000
B 430 000 25 FM

MemoName P SKIP +DUP DTCS W PS

LOW
µ 000 430 00050 µPRIO000
EM

ATT FM

14
FREQUENCY AND CHANNEL SETTING 4

■ Mode selection
D VFO mode D Memory mode
VFO mode is used to set the desired frequency. Memory mode is used for operation on memory channels
which store programmed frequencies.
➥ Push [VFO] to select VFO mode. 4
q Push [MR] to select memory mode.
µ
• “µ ” appears when memory mode is selected.
• VFO mode indication
+DUP DTCS
FM PRIO WX EMR • Memory mode indication
A
145 000 25 +DUP DTCS
FM PRIO WX EMR
MemoName P
145 000 25
SKIP
A
µ 000
LOW
ATT
MemoName P SKIP
µ 000
LOW
ATT

Appear
What is VFO?
VFO is an abbreviation of Variable Frequency Oscillator. Fre- w Rotate [DIAL] to select the desired memory channel.
quencies for both transmitting and receiving are generated • Only programmed memory channels can be selected.
and controlled by the VFO. • Enter the memory channel directly to select the desired memory
channel. (p. 64)
• See p. 66 for memory programming details.

15
4 FREQUENCY AND CHANNEL SETTING

D Call/TV* channels ■ Operating band selection


Call channels are used for quick recall of most-often used fre-
The transceiver can receive the AM broadcast, HF bands,
quencies.
50 MHz, FM broadcast, VHF air, 144 MHz, 300 MHz,
*Appears only when TV channels are programmed via the 400 MHz or 800 MHz* bands. (Some bands are not selectable
optional RS-91. Also available for A band operation only. for B band operation. See next page for details.)

qPush [CALL] several times to select call channels/TV ➥ In VFO mode, push [BAND] several times to select the de-
channels (A band only). sired frequency band.
• Call/TV channels can be selected in sequence. • If the other than VFO mode is selected, such as a memory chan-
w Rotate [DIAL] to select the desired channel. nel/call channel/TV channel, push [VFO] to select VFO mode
• Call channel indication first, then push [BAND] to select the desired band.
[DIAL] +DUP DTCS
➥ While pushing and holding [BAND], rotating [DIAL] also
FM PRIO WX EMR
selects frequency band.
A
145 000 25

MemoName P SKIP
[DIAL]
µ C0
LOW
ATT
+DUP DTCS
FM PRIO WX EMR
• TV channel indication
+DUP DTCS
A
145 000 25
WFM PRIO WX EMR MemoName P SKIP
000
A
10 ch 25 LOW
ATT
µ

MemoName P SKIP
µ TV
LOW
ATT

Available frequency bands are different depending on ver-


sion. See the specification for details. (pgs. 119, 120)
*Some frequency ranges are blocked accordinto trans-
ceiver version.

16
FREQUENCY AND CHANNEL SETTING 4

• Available frequency bands


1
• A band 2
+DUP DTCS +DUP DTCS +DUP DTCS +DUP DTCS
AM PRIO WX EMR AM PRIO WX EMR FM PRIO WX EMR WFM PRIO WX EMR
A
001 620 25 A
005 000 25 A
051 000 25 A
088 000 25 3
MemoName P SKIP MemoName P SKIP MemoName P SKIP MemoName P SKIP 4
AM broadcast band HF band 50 MHz band FM broadcast band 5
6
+DUP DTCS +DUP DTCS +DUP DTCS
FM PRIO WX EMR FM PRIO WX EMR AM PRIO WX EMR 7
A
850 000 25 A
145 000 25 A
118 000 25
MemoName P SKIP MemoName P SKIP MemoName P SKIP
8
800 MHz band 144 MHz band VHF air band 9
+DUP DTCS +DUP DTCS
10
FM PRIO WX EMR FM PRIO WX EMR
A
430 000 25 A
370 000 25 : Push 11
MemoName P SKIP MemoName P SKIP
: Rotating [DIAL] while pushing 12
400 MHz band 300 MHz band Initial frequencies shown differ according to version. 13
• B band 14
+DUP DTCS
AM PRIO WX EMR
+DUP DTCS
FM PRIO WX EMR
+DUP DTCS
FM PRIO WX EMR
+DUP DTCS
FM PRIO WX EMR 15
A
B 118 000 25 A
B 145 000 25 A
B 370 000 25 A
B 430 000 25 16
MemoName P SKIP MemoName P SKIP MemoName P SKIP MemoName P SKIP

17
VHF air band 144 MHz band 300 MHz band 400 MHz band
18
19
17
4 FREQUENCY AND CHANNEL SETTING

■ Setting a tuning step ■ Setting a frequency


The tuning step can be selected for each frequency band. D Using the dial
The following tuning steps are available for the IC-E91. q Push [VFO] to select VFO mode, if necessary.
• 5.0 kHz* • 6.25 kHz* • 8.33 kHz† • 9.0 kHz‡ • 10.0 kHz w Select the desired frequency band with [BAND].
• 12.5 kHz • 15.0 kHz • 20.0 kHz • 25.0 kHz • 30.0 kHz • Or, while pushing and holding [BAND], rotate [DIAL] to select
• 50.0 kHz • 100.0 kHz • 125.0 kHz • 200.0 kHz the desired frequency band.
* Appears for below the 600 MHz bands only. e Rotate [DIAL] to select the desired frequency.
† Appears for the VHF air band only.
• The frequency changes according to the preset tuning steps.
‡ Appears for the AM broadcast band only.
See the left-hand side of the page to set the tuning step.
• Push and hold [MHz](VFO) for 1 sec. then rotate [DIAL] to
change the frequency in 1 MHz steps, or push and hold for 1 sec.
D Tuning step selection again then rotate [DIAL] to change the frequency in 10 MHz
q Push [VFO] to select VFO mode, if necessary. steps. (Each pushing and holding for 1 sec. toggles 1 MHz or
w Push [BAND] to select the desired frequency band. 10 MHz tuning steps. Push [MHz](VFO) to cancel it.)
• Or, while pushing and holding [BAND], rotate [DIAL] to select +DUP DTCS
FM PRIO WX EMR
the desired frequency band. [DIAL]
e Push and hold [TS](8) for 1 sec. to enter tuning step set mode.
A
145 000 25
r Rotate [DIAL] to select the desired tuning step.
t Push [TS](8) (or [VFO]) to return to VFO mode. [DIAL] changes the fre-
quency according to the se-
[DIAL] lected tuning step.

+DUP DTCS +DUP DTCS


FM PRIO WX EMR FM PRIO WX EMR
A
145 000 25 A
145 000 25
P SKIP
µ 000
SET-TS:5.0kHz After pushing and holding
[MHz](VFO) for 1 sec.,
5 kHz tuning step [DIAL] changes the frequen-
cy in 1 MHz/10 MHz steps.

18
FREQUENCY AND CHANNEL SETTING 4

D Using the keypad 1


The frequency can be directly set via numeric • Entering 145.520 MHz • Entering 79.3 MHz • Changing 100 kHz
keys. and below. 2
• If a frequency outside the frequency range is en- +DUP DTCS
FM PRIO WX
+DUP DTCS
FM PRIO WX Editting 3
tered, the previously displayed frequency is auto- A
146 520 25 A
730 000 25 145.520 MHz
matically recalled after editing last digit. to 145.240 MHz 4
qPush [VFO] to select VFO mode, if neces- +DUP DTCS
FM PRIO WX
+DUP DTCS
FM PRIO WX
+DUP DTCS
FM PRIO WX 5
sary.
A
146 520 25 A
790 000 25 A
145 240 25
w Enter the desired frequency via the keypad.
6
+DUP DTCS
FM PRIO WX
+DUP DTCS
FM PRIO WX
+DUP DTCS
FM PRIO WX
7
A
145 520 25 A
079 300 25 A
145 240 25 8
+DUP DTCS +DUP DTCS +DUP DTCS
9
FM PRIO WX FM PRIO WX FM PRIO WX
A
145 520 25 A
079 300 25 A
145 240 25 10
11
+DUP DTCS +DUP DTCS +DUP DTCS

A
FM PRIO WX

145 520 25 A
FM PRIO WX

079 300 25 A
FM PRIO WX

145 240 25 12
13
+DUP DTCS +DUP DTCS
FM PRIO WX FM PRIO WX
14
A
145 520 25 A
079 300 25
15
• Editting to 684 kHz 16
+DUP DTCS

Depending on the tuning step setting, the 1 A


FM PRIO WX

000 684 25 17
kHz digit may not acceptable as input. In 18
this case, enter “0” as 1 kHz digit, then ro-
tate [DIAL] to set the desired frequency. 19
19
5 BASIC OPERATION

■ Receiving ■ Setting audio volume


Make sure charged battery pack (BP-217) or brand new al- ➥ Rotate [VOL] to adjust the audio level.
kaline batteries (BP-216) are installed (pgs. 1, 12). • If squelch is closed, push and hold [SQL] to verify the audio
level.
q Push and hold [PWR] for 1 sec. to turn power ON. • The display shows the volume level while setting.
wRotate [VOL] to set the desired audio level.
+DUP DTCS
• The frequency display shows the volume level while setting. See FM PRIO WX EMR
the section at right for details. [VOL]
A
145 000 25
e Set the receiving frequency. (p. 18) MemoName P SKIP

r Set the squelch level. (p. 21) µ 000


LOW
• While pushing and holding [SQL], rotate [DIAL]. ATT

• The first click of [DIAL] indicates the current squelch level.


• “LEVEL 1” is loose squelch (for weak signals) and “LEVEL 9” is
P SKIP
tight squelch (for strong signals). µ 000
• “AUTO” indicates automatic level adjustment by a noise pulse VOL
counting system.
• Push and hold [SQL] to open the squelch manually. Volume level indicator
tWhen a signal is received:
• Squelch opens and audio is output.
P SKIP
• The S/RF-meter shows the relative signal strength level. µ 000
VOL
e Set frequency
r Set squelch level Minimum setting
(no audio)
r Push for setting w Set audio level
P SKIP
the squelch µ 000
(Push to monitor) VOL

Maximum setting

e Select band
q [PWR]

20
BASIC OPERATION 5

■ Setting squelch level ■ Operating mode selection 1


The squelch circuit mutes the received audio signal depend- Operating modes are determined by the modulation of the 2
ing on the signal strength. The receiver has 9 squelch levels, radio signals. The transceiver has total 5 operating modes (A
a continuously open setting and an automatic squelch setting. band: FM, WFM and AM modes, B band FM, FM-N, AM and
3
➥ While pushing and holding [SQL], rotate [DIAL] to select
DV modes). The mode selection is stored independently for 4
each band and memory channel.
the squelch level. 5
• “LEVEL 1” is loose squelch (for weak signals) and “LEVEL 9” is Typically, AM mode is used for the AM broadcast stations
tight squelch (for strong signals). 6
(0.495–1.620 MHz) and air band (118–136.995 MHz), and
• “AUTO” indicates automatic level adjustment by a noise pulse
counting system.
WFM is used for FM broadcast stations (76–107.9 MHz). 7
• “OPEN” indicates continuously open setting.
➥ Push and hold [MODE](REC) for 1 sec. several times to 8
+DUP DTCS
[DIAL] FM PRIO WX EMR select the desired operating mode. 9
A
145 000 25 • Display example
10
MemoName P SKIP
µ 000 FM
11
145 000 25
LOW
ATT A

12
FM mode
P SKIP
13
µ 000 WFM

SQUELCH:AUTO A
176 000 25 14
Automatic squelch 15
WFM mode
P SKIP
µ 000
AM
16
SQUELCH:LEVEL9
Maximum level
A
118 000 25 17
AM mode 18
19
21
5 BASIC OPERATION

■ Monitor function ■ Attenuator function


This function is used to listen to weak signals without disturb- The attenuator prevents a desired signal from distortion by
ing the squelch setting or to open the squelch manually even very strong signals near the desired frequency or when very
when mute functions such as the tone squelch are in use. strong electric fields, such as from a broadcasting station, are
near your location. The attenuation is about 10 dB.
➥ Push and hold [SQL] to monitor the operating frequency.
• The 1st segment of the S-meter blinks. q Enter “ATTENUATOR” in set mode. (p. 88)
MENU screen ➪ SET MODE ➪ ATTENUATOR
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
+DUP DTCS
FM PRIO WX EMR
w Rotate [DIAL]† to select “ON” or “OFF.”
A
145 000 25 e Push [ï](5) (or [ΩΩ](4)) to return to set mode, and push
MemoName P SKIP
µ 000 [MENU/LOCK] to return to frequency indication.
LOW
ATT • “ATT” appears on the function display when “ON” is selected.
The 1st segment blinks
[DIAL]

+DUP DTCS
FM PRIO WX EMR

The [SQL] key can be set to ‘sticky’ operation in set mode. A


145 000 25
See page 89 for details. MemoName P SKIP
µ 000
LOW
ATT

Appears.

†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
22
BASIC OPERATION 5

■ Band scope 1
The band scope function allows you to visually check a spec- D Continuous sweep 2
ified frequency range around the center frequency. q Set the desired frequency as band scope center frequency.
3
w Push and hold [SCOPE](1) for 3 sec. to start continuous
About the sweep steps: The specified tuning step in each 4
sweep.
frequency band (in VFO mode) or programmed tuning step
• 2 short beeps sound after 1 short and 1 long beeps.
(in memory mode) is used during sweep. 5
• Signal conditions (strengths) appear starting from the center of
+DUP DTCS the range. 6
FM PRIO WX EMR
e Push and hold [SCOPE](1) for 1 sec. to cancel sweep.
A
B 145 780 25 • Pushing [SQL] also cancels sweep.
7
µ
P SKIP
000 r Push [VFO] to return to normal operation. 8
9
10
Band scope indication Sweep marker +DUP DTCS
FM PRIO WX EMR
A
B 145 780 25 11
D Single sweep
µ
P SKIP
000 12
q Set the desired frequency as band scope center frequency. 13
w Push and hold [SCOPE](1) for 1 sec. to start a single 14
sweep.
• 1 short and 1 long beeps sound. The receive audio during sweeping can be muted in 15
• Signal conditions (strengths) appear starting from the center of sounds set mode. See page 102 for details. 16
the range.
e Rotate [DIAL] to set the highlighted cursor to the desired 17
signal and set the frequency of the signal. 18
r Push [VFO] to return to normal operation.
19
23
5 BASIC OPERATION

■ Transmitting ■ Transmit power selection


The transceiver has two output power levels to suit your op-
CAUTION: Transmitting without an antenna will damage
erating requirements. Low output power during short-range
the transceiver.
communications may reduce the possibility of interference to
NOTE: To prevent interference, listen on the channel be- other stations and will reduce current consumption.
fore transmitting by pushing and holding [SQL].
➥ Push and hold [LOW](3) for 1 sec. to toggle the transmit
output power between High and Low.
qSet the operating frequency.
• “LOW” appears when the low power is selected.
(pgs. 18, 19)
• Transmission is available on the +DUP DTCS
144 MHz/430 MHz amateur bands FM PRIO WX EMR

only. A
145 000 25
• Select output power if desired. See MemoName P SKIP

the section at right for details. µ 000


LOW
ATT
w Push and hold [PTT] to transmit.
• Tx/Rx indicator lights red. Appears
• S/RF meter shows the output Tx/Rx
power level. indicator Microphone LOW

eSpeak into the microphone using


Low power transmission
your normal voice level.
• DO NOT hold the transceiver too close to your mouth or speak
LOW
too loudly. This may distort your speech.
r Release [PTT] to return to receive. High power transmission

WARNING! NEVER continuously transmit the transceiver for long periods of time. When the transceiver is used for continuous
prolonged transmission at high power, the transceiver radiates heat to protect itself from overheating and transceiver’s chassis
will become hot. This may cause a burn.
AVOID operating the transceiver in a situation that will obstruct heat dissipation, especially if the transceiver is operated with an
external power supply. Heat dissipation may be affected, and it may cause a burn, warp the casing or damage the transceiver.
24
BASIC OPERATION 5

■ Lock function ■ Dualwatch operation 1


To prevent accidental frequency changes and unnecessary Dualwatch operation monitors two frequencies simultane- 2
function access, use the lock function. ously. The IC-E91 has two independent receiver circuits as A
band and B band (available frequency bands and operating mode
3
➥ Push and hold [MENU/LOCK] for 1 sec. to turn the lock are different depending on bands). 4
function ON and OFF.
•“ ” appears while the lock function is activated. 5
• The squelch control and volume control can be used while the D Dualwatch operation
lock function is in use with default setting. Either or both the ➥ Push and hold [MAIN/DUAL] for 1 sec. to turn the dual- 6
squelch control and volume control can also be locked in set watch operation ON and OFF.
• While in dualwatch operation, the display indicates A band in the
7
mode. (p. 90)
upper half and B band in the lower half. 8
Appears +DUP DTCS
FM PRIO WX EMR 9
A
145 000 25 10
+DUP DTCS MemoName P SKIP
µ 000
FM PRIO WX EMR
11
A
145 000 25 LOW
ATT

MemoName P SKIP 12
µ 000
LOW
ATT
+DUP DTCS W PS
13
145 000 25 µPRIO000 14
FM
+DUP DTCS

430 00050 µPRIO000


EM
W PS
15
FM
16
17
18
19
25
5 BASIC OPERATION

D Main band selection D Setting audio volume


➥ Push [MAIN/DUAL] to select A band or B band as the The audio level for dualwatch operation can be adjusted both
main operating band alternately. on A band and B band simultaneously (default).
This setting can be set separately for each band in sounds
+DUP DTCS W PS

145 000 25 µPRIO000 set mode.


FM
+DUP DTCS W PS qPush and hold [MAIN/DUAL] for 1 sec. to enter the dual-
430 00050 µPRIO000
EM
watch operation, if necessary.
FM
wRotate [VOL] to adjust the audio level for the main band.
• If squelch is closed, push and hold [SQL] to verify the audio
level.
+DUP DTCS W PS • The display shows the volume level while setting.
145 000 25 µPRIO000 +DUP DTCS W PS
FM
+DUP DTCS W PS [VOL] 145 000 25 µPRIO000
430 000 50 PRIO EM
µ 000
FM
+DUP DTCS W PS
FM
430 00050 µPRIO000
EM

FM

+DUP DTCS W PS
PRIO
145 000 25 µ 000
VOL
+DUP DTCS W PS

430 00075 µ PRIO EM


000
FM

Setting for A band (upper side)


+DUP DTCS W PS

145 00025 µPRIO000


FM
+DUP DTCS W PS
PRIO EM
430 000 75 µ 000
VOL

Setting for B band (lower side)


26
BASIC OPERATION 5

D Volume setting for dualwatch D Setting squelch level 1


The volume setting for dualwatch can be set for both bands qPush and hold [MAIN/DUAL] for 1 sec. to enter the dual-
simultaneously or for each band separately in set mode. watch operation, if necessary
2
q Enter “VOLUME SELECT” in sounds set mode. (p. 102) wWhile pushing and holding [SQL], rotate [DIAL] to adjust 3
the main band’s squelch level.
MENU screen ➪ SOUNDS ➪ VOLUME SELECT 4
• “LEVEL 1” is loose squelch and “LEVEL 9” is tight squelch.
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
• “AUTO” indicates automatic level adjustment with a noise pulse 5
w Rotate [DIAL]† to select “BOTH” or “SEPARATE.” count system.
e Push [ï](5) (or [Ω
Ω](4)) to return to sounds set mode, and • “OPEN” indicates continuously open setting. 6
push [MENU/LOCK] to return to frequency indication. [DIAL] +DUP DTCS W PS
7
145 000 25 µPRIO000
FM
+DUP DTCS W PS
8
430 00050 µPRIO000
EM

9
FM

10
+DUP DTCS W PS
PRIO
11
145 000 25 µ 000
SQUELCH:AUTO
+DUP DTCS W PS
12
430 00075 µPRIO000
EM
13
FM

Setting for A band (Upper) 14


+DUP DTCS W PS 15
145 00025 µPRIO000
FM
+DUP DTCS W PS
16
PRIO EM
430 000 75 µ
SQUELCH:LEVEL6
000 17
Setting for B band (Lower) 18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
27
5 BASIC OPERATION

■ TV channel operation
TV channel operation is available only when TV channels are w Rotate [DIAL] to select the channel to be skipped.
programmed using the optional RS-91. (p. 121) Also available • To clear the skip setting, rotate [DIAL] while pushing and holding
for A band operation only. [BAND] to select a skip channel.
e Push and hold [SKIP](5) for 1 sec. to toggle the skip set-
D TV channel receiving ting ON and OFF.
• “SKIP” appears when the channel is set as skip channel.
q Push [CALL] several times to select TV channels.
• “TV” and channel number appear. [DIAL]
Appears
w Rotate [DIAL] to select the desired channel.
+DUP DTCS
• While pushing and holding [BAND], rotating [DIAL] selects the WFM PRIO WX EMR
all channels including skip channel. A
12 ch 25

[DIAL] MemoName P SKIP


TV mode indication µ TV
LOW
ATT
Channel indication
+DUP DTCS
WFM PRIO WX EMR
A
10 ch 25

MemoName P SKIP

LOW
µ TV D Automatic TV channel programming
ATT
TV channels can be programmed automatically.
q Push [CALL] several times to +DUP DTCS
WFM PRIO WX EMR

D Skip channel setting


select TV channels.
• “TV” and channel number ap-
A
2 ch 25

Unwanted channels can be skipped for rapid selection, etc. pear. MemoName P SKIP
µ TV
q Push [CALL] several times to select TV channels. w Push [SCAN](2) to start TV LOW
ATT

• “TV” and channel number appear. channel programming.


• The programming will automati-
cally stop after scanning all channels.

28
REPEATER AND DUPLEX OPERATIONS 6
■ General 1
Repeaters allow you to extend the operational range of your • Repeater operation flow chart 2
radio because a repeater has much higher output power than
the typical transceiver.
Step 1: 3
Set the desired band to operate the repeater.
4
Normally, a repeater has independent frequencies for each
receiver and transmitter. 5
Step 2:
A subaudible tone may also be required to access a repeater.
Set the desired receive frequency (repeater output frequency). 6
Reference amateur radio hand books and local ham maga- 7
zines for details of local repeaters such as repeater input/out-
put frequencies and locations. Step 3: 8
Set the duplex (shifting) direction (– duplex or +duplex).
- Set the offset frequency (shifting value), if required. 9
Repeater
144.700 MHz 144.700 MHz Uplink 10
(transmitting freq.)
Downlink
(receiving freq.)
11
145.300 MHz 145.300 MHz Step 4:
Set the subaudible tone (repeater tone) encoder function ON. 12
- Set the subaudible tone frequency, if required.
Station A Station B 13
• Repeater settings can be stored into a memory channel. 14
15
16
17
18
19
29
6 REPEATER AND DUPLEX OPERATIONS

■ Accessing a repeater
q Set the receive frequency (repeater output frequency). r Push and hold [PTT] to transmit.
w Set the shift direction of the transmit frequency. (–DUP or • The displayed frequency automatically changes to the transmit
+DUP; see p. 32 for details.) frequency (repeater input frequency).
• If “OFF” appears, check the offset frequency or shift direction.
“–DUP”or “+DUP” appears.
(p. 30)
-DUP TONE
FM  
   

A
145300 -DUP TONE
FM
-DUP TONE
FM
A
145 300 A
144700
P SKIP P SKIP

e Push and hold [TONE](7) for 1 sec. to activate the sub-


audible tone encoder, according to repeater requirements.
• “TONE” appears. t Release [PTT] to receive.
Refer to p. 107 for tone frequency settings.
y Push and hold [SQL] to check whether the other station’s
transmit signal can be directly received or not.

30
REPEATER AND DUPLEX OPERATIONS 6

1
D Checking the repeater input signal D Off band indication 2
The transceiver can check whether the other station’s trans- If the transmit frequency is out of the amateur band, the off 3
mit signal can be received directly or not, by listening on the band indication, “OFF,” appears on the display when [PTT] is
repeater input frequency. pushed. Check the offset frequency or duplex direction in this
4
case. (p. 32) 5
➥ Push and hold [SQL] to check whether the other station’s -DUP TONE
transmit signal can be directly received or not. FM 6
A
OFF
• When the other station’s signal can be directly received, move
7
to a non-repeater frequency to use simplex. (duplex OFF) P SKIP

8
Indication while receiving.
-DUP TONE
9
FM
A
145300 ✔ CONVENIENT! 10
P SKIP
Tone scan function: When you don’t know the subaudible
tone used for a repeater, the tone scan is convenient for de-
11
Push and hold tecting the tone frequency. 12
➥ Push and hold [T.SCAN](9) for 1 sec. to start the tone
Receives –0.6 MHz shift frequency. scan. See p. 112 for more information.
13
-DUP TONE

A
FM

144 700
14
P SKIP
15
16
Blinks while pushing and holding [SQL].
17
18
19
31
6 REPEATER AND DUPLEX OPERATIONS

■ Duplex operation
Although [DIAL] and [ï](5) are used for description in this D Setting duplex direction
∫](2)/[√
section, [∫ √](8) and [≈
≈](6) are available instead of ➥ Push and hold [DUP](4) for 1 sec. to select “–DUP” or
[DIAL] and [ï](5). “+DUP”.
• “–DUP” or “+DUP” indicates the transmit frequency for minus
D Setting offset frequency shift or plus shift, respectively.
• When offset frequency is 0.6 MHz.
q Enter “OFFSET FREQ” in DUP/TONE… set mode. (p. 97)
MENU screen ➪ DUP/TONE… ➪ OFFSET FREQ
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)

w Rotate [DIAL]† to set offset frequency.


• 1 MHz and 10 MHz tuning steps are available by pushing and
holding [MHz](VFO) for 1 sec.: push [MHz](VFO) to cancel it.
e Push [ï](5) (or [ΩΩ](4)) to return to DUP/TONE… set mode,
and push [MENU/LOCK] to return to frequency indication.

No offset frequency 5.0 MHz offset


OFFSET FREQ OFFSET FREQ
0.000.00 5.000.00

†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
32
REPEATER AND DUPLEX OPERATIONS 6

■ 1750 Hz tone 1
Some European repeaters require a 1750 Hz tone burst to be i Push and hold [PTT] to transmit. 2
accessed. For such European repeaters, perform the follow- o Release [PTT] to receive.
ing. !0 Push and hold [SQL] to check whether the other station’s
3
• This tone can be use as a ‘Call signal’ in countries out of Europe. transmit signal can be received directly or not, by listening 4
on the repeater input frequency.
q Push and hold [DTMF.M](.) for 1 sec. to select DTMF 5
memory.
6
DTMF MEMORY
r Ch01 7
8
w Rotate [DIAL]† counter-clockwise until “T-CALL” appears. 9
DTMF MEMORY
r T-CALL 10
11
e Push [ï](5) to set. 12
r Push [VFO] to exit DTMF memory.
t Set the receive frequency (repeater output frequency). 13
y Set the shift direction of the transmit frequency. (–DUP or 14
+DUP; see p. 32 for details.)
u While pushing [PTT], push [SQL] to transmit a 1750 Hz 15
tone burst signal. 16
• If “OFF” appears, check the offset frequency or shift direction.
(p. 97) 17
• The displayed frequency automatically changes to the transmit
18
frequency (repeater input frequency).
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8)
33
7 DV MODE OPERATION (Optional UT-121 is required)

Although [DIAL] and [ï](5) are used for description in this D Your own call sign programming
∫](2)/[√
section, [∫ √](8) and [≈
≈](6) are available instead of Your own call sign must be programmed for both digital voice
[DIAL] and [ï](5). and low-speed data communications (including GPS transmis-
sion).

q Select B band as the main band. (p. 14)


■ Digital mode operation w Enter “MY” in call sign set mode.
MENU screen ➪ CALL SIGN ➪ MY
When the optional UT-121 is installed, the IC-E91 can be op- (Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
erated in digital voice mode and low-speed data operation for
both transmit and receive. It can also be connected to a GPS • MY CALL SIGN screen is displayed.
receiver (compatible with an RS-232 output/NMEA format/4800 bps) MY CALL SIGN
r M01
and transmit/receive position data.
/
:SET :SEL
:BACK :EDIT
CLR:CLR

■ Call sign programming e Rotate [DIAL]† to select the desired call sign memory,
Four types of call sign memories are available; your own call “M01” to “M06.”
sign “MY CALL SIGN,” other station call sign “YOUR CALL r Push [≈
≈](6) to enter call sign programming mode.
SIGN,” repeater call sign “RPT1 CALL SIGN” and “RPT2 • The 1st digit blinks.
CALL SIGN.” “MY CALL SIGN” can store up to 6 call signs, MY CALL SIGN
r M01 AB
“YOUR CALL SIGN” can store up to 60 call signs and

“RPT1/2 CALL SIGN” can store up to 60 call signs, and each /
:SET CLR:CLR
call sign can be programmed with up to 8 characters. :SEL A/a:CHAR
:CUR

t Rotate [DIAL]† to select the desired character or code.


• Push [A/a](3) to change the character group from “AB” (alpha-
betical characters; capital letters), “12” (numbers) and “/” (sym-
bols) in sequence.

34
DV MODE OPERATION (Optional UT-121 is required) 7

1
y Push [≈ ≈](6) to select 2nd digit, then rotate [DIAL]† to se- !0 Push [ï](5) to store the programmed call sign with note
lect the desired character or code. and returns to MY CALL SIGN screen. 2
• Push [≈≈](6) to move the cursor right; push [Ω
Ω](4) to move the !1 Push [MENU/LOCK] to return to frequency indication. 3
cursor left.
• 2nd digit blinks (1st digit stops blinking). 4
r
MY CALL SIGN
M01 AB
5
M†
/
6
:SET CLR:CLR
:SEL
:CUR
A/a:CHAR
7
u Repeat the steps t and y to enter your own call sign. 8
• Up to a 8-digit of call sign can be set. 9
• If an un-necessary character is entered, push [≈≈](6) or [Ω
Ω](4) to
select the character, then push [CLR](1) to erase the selected 10
character, or push and hold [CLR](1) for 1 sec. to erase all char-
acters following the cursor. 11
• When programming a note (Up to a 4-digit for operating radio
type or area, etc.), go to step i, otherwise go to step !0.
12
i Push [≈≈](6) several times to set the cursor beside “/” indi- 13
cation.
o Repeat steps t to y to program the desired 4-character
14
note. 15
MY CALL SIGN
r M01 16
MYCALL
/IC91
:SET :SEL
17
:BACK :EDIT
CLR:CLR 18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
35
7 DV MODE OPERATION (Optional UT-121 is required)

D Station call sign programming


Station call sign must be programmed for the specified sta- y Push [≈ ≈](6) to select 2nd digit, then rotate [DIAL]† to se-
tion call as well as repeater operation in both digital voice and lect the desired character or code.
low-speed data communications. • Push [≈≈](6) to move the cursor right; push [Ω
Ω](4) to move the
cursor left.
q Select B band as the main band. (p. 14) • 2nd digit blinks (1st digit stops blinking).
w Enter “UR” in call sign set mode. YOUR CALL SIGN
rU01 AB
MENU screen ➪ CALL SIGN ➪ UR
S†
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
:SET CLR:CLR
:SEL A/a:CHAR
• YOUR CALL SIGN screen is displayed.
:CUR 0:CQ
YOUR CALL SIGN
r U u Repeat the steps t and y to enter the desired station call
CQCQCQ
sign.
:SET :SEL
:BACK :EDIT
• Up to an 8-digit of call sign can be set.
CLR:CLR ≈](6) or [Ω
• If an un-necessary character is entered, push [≈ Ω](4) to
select the character, then push [CLR](1) to erase the selected
e Rotate [DIAL]† to select the desired call sign memory, character, or push and hold [CLR](1) for 1 sec. to erase all char-
“U01” to “U60.” acters following the cursor.
r Push [≈
≈](6) to enter call sign programming mode. YOUR CALL SIGN
• The 1st digit blinks. r U01
STATION1
YOUR CALL SIGN
rU01 AB :SET :SEL
† :BACK :EDIT
CLR:CLR
:SET CLR:CLR
:SEL A/a:CHAR
:CUR 0:CQ
i Push [ï](5) to store the programmed call sign and returns
to YOUR CALL SIGN screen.
t Rotate [DIAL]† to select the desired character or code. o Push [MENU/LOCK] to return to frequency indication.
• Push [A/a](3) to change the character group from “AB” (alpha-
betical characters; capital letters), “12” (numbers) and “/” (sym-
bols) in sequence.

36
DV MODE OPERATION (Optional UT-121 is required) 7

NOTE: During the call sign programming mode (r to u), 1


push [CQ](0) to set “CQCQCQ,” and push [CQ](0) again
to return to the previously stored call sign. 2
3
✔ For your information
The IC-E91 has call sign edit record function. 4
When editing a call sign stored in a call sign memory, regular 5
memory or call channel, the default setting is to store the
edited call sign into a blank channel automatically. (“FULL” is 6
displayed when all call sign memory is programmed.) 7
The edited call sign can be over-written when the setting of
the EDIT RECORD is set to OFF or SELECT. (p. 95) 8
However, you must manually over-write a programmed call
sign in regular memory and call channels. (Temporary opera-
9
tion without over-writing is possible.) 10
11
12
13
14
15
16
17
18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
37
7 DV MODE OPERATION (Optional UT-121 is required)

■ Digital voice mode operation


qSet the desired frequency in B band. (pgs. 14, 18) NOTE: The digital mode operation is vastly different from
• Select output power, if desired. (p. 24) FM mode. One of the differences is in digital mode the
w Select DV mode. (p. 21) squelch does not function as in FM mode. Changing the
e Set your own call sign for DV operation as follows. squelch setting will not open it to hear the hiss of “White
z Enter “MY” in call sign set mode. Noise.” It only activates for digital squelch functions such
MENU screen ➪ CALL SIGN ➪ MY as CSQL (Digital code squelch) or DSQL (Digital call sign
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) squelch).
xRotate [DIAL]† to select the desired your own call sign
channel (if you have programmed several call signs) then
push [ï](5) to set the call sign and return to CALL SIGN
screen.
• See page 34 for your own call sign programming details.
CALL SIGN
r UR:
R1:
R2:NOT USE*
MY:MYCALL
/IC91

rSet the desired call sign as described in “When calling the


desired station (p. 39)” or “When sending a CQ (p. 39).”
tPush and hold [PTT] to transmit and speak into the micro-
phone at normal voice level.
• Tx/Rx indicator lights red and the RF meter shows the output
power.
y Release [PTT] to return to receive.
• The other station call sign will be received.
• Received call signs can be stored into the received call record
automatically. See page 93 for details.

38
DV MODE OPERATION (Optional UT-121 is required) 7

D When calling the desired station D When sending a CQ 1


Continued instruction from step x on page 38. Continued instruction from step x on page 38.
2
cRotate [DIAL]† to select “UR,” then push [ï](5)†. cRotate [DIAL]† to select “UR,” then push [ï](5)†. 3
• YOUR CALL SIGN screen is displayed. • YOUR CALL SIGN screen is displayed.
vRotate [DIAL]† to select the call sign channel in which de- vRotate [DIAL]† to select the call sign channel in which 4
sired station’s call sign is programmed. “CQCQCQ” is programmed.
• See page 36 for station call sign programming details. ≈](6) and [CQ](0) in sequence to
Or, select “U” then push [≈
5
bPush [ï](5) to set the station’s call sign and return to set “CQCQCQ.” 6
CALL SIGN screen. bPush [ï](5) to set “CQCQCQ” as the call sign and return
CALL SIGN to CALL SIGN screen.
7
r UR:STATION1
R1:
CALL SIGN 8
r UR:CQCQCQ
R2:NOT USE*
MY:MYCALL
R1: 9
R2:NOT USE*
/IC91
MY:MYCALL 10
/IC91
nPush [MENU/LOCK] to return to frequency indication. 11
m Perform the instruction steps t and y on page 38. nPush [MENU/LOCK] to return to frequency indication.
m Perform the instruction step t and y on page 38.
12
13
14
15
16
17
18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
39
7 DV MODE OPERATION (Optional UT-121 is required)

■ About D-STAR system For current repeater operation, stations that are communicat-
ing must both be in the same repeater’s operating area.
In the D-STAR system, repeater linking via a 10 GHz band However, in the D-STAR system as in the illustration at left,
backbone and internet network (gateway connection) capa- the repeaters can be linked via the system repeaters (with a
bilities are available. This system provides you to with much 10 GHz signal). Thus stations A and B can communicate even
wider coverage range during digital voice mode operation. though they are in different repeater operating areas.
• D-STAR system outline Also, the D-STAR system repeaters are connectable through
the internet— gateway connection capability.
For example, when station B uses the gateway connection
Repeater A 10 GHz
station B can communicate with the station C!
Repeater B By using the gateway connection, long distance communica-
144/430 MHz tion like DX operation may be possible with 144 or 430 MHz
144/430 MHz digital voice!

Station Station In the D-STAR system, an independent repeater’s operating


A B area is called an Area and a group that of linked repeaters via
a 10 GHz backbone is called a Zone.
Internet
network NOTE: The digital repeater for IC-E91 (144 MHz or
430 MHz of amateur radio band operation) is not available
in European countries at present of May 2006.

10 GHz Repeater D
Repeater C
About time-out timer function
144/430 MHz The IC-E91 has a time-out timer function for digital re-
144/430 MHz
peater operation. The timer limits a continuous transmis-
sion for approx. 10 min. Warning beeps will sound before
Station C Station D
30 sec. (approx.) and just before the timer functioning.
40
DV MODE OPERATION (Optional UT-121 is required) 7

■ Digital repeater operation 1


Repeater call signs must be programmed for repeater opera- u Repeat the steps t and y to enter the desired repeater 2
tion in both digital voice and low-speed data communications. call sign.
• Up to an 8-digit of call sign can be set. 3
D Repeater call sign programming • Push [7] when setting with the gateway connection if the se- 4
lected repeater has gateway capability. (The gateway connec-
q Select B band as the main band. (p. 14) tion can be set in RPT1 only when “NOT USE✱” is set to RPT2.) 5
w Enter “R1” or “R2” in call sign set mode. ≈](6) or [Ω
• If an un-necessary character is entered, push [≈ Ω](4) to
MENU screen ➪ CALL SIGN ➪ R1/R2 select the character, then push [CLR](1) to erase the selected 6
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) character, or push and hold [CLR](1) for 1 sec. to all characters
following the cursor.
7
• RPT1 or RPT2 CALL SIGN screen is displayed.
e Rotate [DIAL]† to select the desired call sign memory, RPT1 CALL SIGN 8
r R01
“R01” to “R60.” RPT1AA G 9
r Push [≈
≈](6) to enter call sign programming mode.
• The 1st digit blinks.
:SET
:BACK
:SEL
:EDIT 10
CLR:CLR
t Rotate [DIAL]† to select the desired character or code. 11
• Push [A/a](3) to change the character group from “AB” (alpha- i Push [ï](5) to store the programmed call sign and returns
betical characters; capital letters), “12” (numbers) and “/” (sym-
to RPT1 or RPT2 CALL SIGN screen. 12
bols) in sequence.
o Push [MENU/LOCK] to return to frequency indication. 13
• Set “/” at the 1st digit then set the desired area repeater’s call
sign (in a different zone) for CQ call (“/” stands for “CQCQCQ”) in
a different zone operation. (p. 44)
14
y Push [≈ ≈](6) to select 2nd digit, then rotate [DIAL]† to se- 15
lect the desired character or code.
• Push [≈≈](6) to move the cursor right; push [Ω
Ω](4) to move the 16
cursor left. 17
• 2nd digit blinks (1st digit stops blinking).
18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
41
7 DV MODE OPERATION (Optional UT-121 is required)

D Repeater operation in the same zone


qSet the desired repeater’s frequency, offset and shift direc- t Push [PTT] to transmit; release to receive.
tion in B band. (pgs. 18, 32)
• Select DV mode in advance. (p. 21)
w Set your own call sign. (p. 38)
• See p. 34 for your own call sign programming.
e Set the desired station call sign. (p. 39)
• See p. 36 for station call sign programming.
r Set the repeater’s call sign as follows;
z Enter “R1” in call sign set mode.
MENU screen ➪ CALL SIGN ➪ R1
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)

xRotate [DIAL]† to select the nearest repeater’s call sign.


cPush [ï](5) to set the call sign for “R1.”
• Return to CALL SIGN screen.
vRotate [DIAL]† to select “R2” then push [ï](5)†.
• RPT2 CALL SIGN screen is displayed.
bRotate [DIAL]† to select the desired repeater’s (in the
same zone) call sign.
• Select “NOT USE✱” when not operating RPT2.
nPush [ï](5) to set the call sign for “R2.”
• Return to CALL SIGN screen.
CALL SIGN
r UR:CQCQCQ
R1:RPT1AA
R2:NOT USE*
MY:MYCALL
/IC91

mPush [MENU/LOCK] to return to frequency indication. †[DIAL] ↔ [∫


∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
42
DV MODE OPERATION (Optional UT-121 is required) 7

• Setting example 1 1
2
Zone
3
4
Area 1 Repeater 1 Area 2 Repeater 2 Area 3 Repeater 3 Area 4 Repeater 4
: A11111 : A22222 (Gateway) : A33333 : A44444
5
6
7
Station A Station C
: A2222A Station B
Internet : A4444C 8
: A2222B
network 9
✔ What is the area? ✔ What is the zone?
The Area is the communication range that is The Zone is composed of several areas, that 10
covered by a local repeater. are linked by the 10 GHz microwave signal.
A Local repeater is called an area repeater in to another Zone The areas 1 to 4 make up a zone in the exam- 11
the D-STAR system. ple above.
12
13
14
15
❑ The setting when Station A is call- ❑ The setting when Station A is mak- ❑ The setting when Station A is call- 16
ing Station B ing a CQ call in area 1 ing Station C
UR : A2222B UR : CQCQCQ UR : A4444C 17
R1 : A22222 R1 : A22222 R1 : A22222 18
R2 : NOT USEQ R2 : A11111 R2 : A44444
MY : A2222A MY : A2222A MY : A2222A
19
43
7 DV MODE OPERATION (Optional UT-121 is required)

D Repeater operation into another zone


qSet the desired repeater’s frequency, offset and shift direc- nPush [ï](5) to set the call sign for “R2.”
tion in B band. (pgs. 18, 32) • Return to CALL SIGN screen.
• Select DV mode in advance. CALL SIGN

w Set your own call sign. (p. 38) r UR:CQCQCQ


R1:RPT1AA
• See p. 34 for your own call sign programming.
R2:NOT USE*
e Set the desired station call sign. (p. 39) MY:MYCALL
• When making a CQ call /IC91
Set the desired repeater’s (in a different zone) call sign with
a “/” symbol at the 1st digit, for the area in which you mPush [MENU/LOCK] to return to frequency indication.
want to make a CQ call, into “UR.” t Push [PTT] to transmit; release to receive.
• See p. 36 for station call sign programming.
r Set the repeater’s call sign as follows;
z Enter “R1” in call sign set mode.
MENU screen ➪ CALL SIGN ➪ R1
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)

xRotate [DIAL]† to select the nearest repeater’s call sign.


• If the nearest repeater is gateway repeater, select the re-
peater’s call sign with “G” setting at the 8th digit.
cPush [ï](5) to set the call sign for “R1.”
• Return to CALL SIGN screen.
vRotate [DIAL]† to select “R2” then push [ï](5)†.
bRotate [DIAL]† to select the gateway repeater’s (in the
same zone) call sign.
• The call sign should have “G” setting at the 8th digit.
• When gateway repeater call sign is set in “R1,” select “NOT
USE✱” for “R2” setting.

†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
44
DV MODE OPERATION (Optional UT-121 is required) 7

• Setting example 2 1
Zone A
2
Repeater 3 3
Area 1 Area 2 : A33333 Area 4
Area 3
(Gateway)
4
Repeater 1 Repeater 2 Repeater 4
: A11111 : A22222 : A44444 5
Station A 6
: A2222A Station B
Internet : A3333B 7
network 8
Zone B 9
10
Area 5 Area 6 Area 8 11
Repeater 5 Area 7
: B55555 (Gateway)
Repeater 6 Repeater 7 Repeater 8 12
: B66666 : B77777 : B88888
13
Station C
: B6666C 14
15
❑ The setting when Station A is call- ❑ The setting when Station A is mak- ❑ The setting when Station B is call- 16
ing Station C ing a CQ call in area 8 ing Station C
UR : B6666C UR : /B88888 UR : B6666C 17
R1 : A22222 R1 : A22222 R1 : A33333 G 18
R2 : A33333 G R2 : A33333 G R2 : NOT USE✱
MY : A2222A MY : A2222A MY : A3333B
19
45
7 DV MODE OPERATION (Optional UT-121 is required)

■ Received call sign • Station call sign • Called station call sign
RX CALL SIGN RX CALL SIGN
When a call is received in DV mode, the calling station and r RX01 r RX01
the repeater call signs being used can be stored into the re- CALLER: CALLED:
AAAAAA CQCQCQ
ceived call record. The stored call signs are viewable in the /
:CALLED :SEL :RXRPT1 :SEL
following manner. :COPY CLR:CLR :COPY CLR:CLR

Up to 20 calls can be recorded. Push

D Desired call record indication


q Enter RX call sign set mode. RX CALL SIGN
r
RX CALL SIGN
r
RX01 RX01
MENU screen ➪ RX CALL SIGN RXRPT2: RXRPT1:
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
:CALLER :SEL :RXRPT2 :SEL
• RX CALL SIGN screen is displayed. :COPY CLR:CLR :COPY CLR:CLR
wRotate [DIAL]†
to select the desired record channel. • Repeater 2 call sign • Repeater 1 call sign
eTo confirm the received call, push [ï](5) several times to
select the desired call sign from CALLER, CALLED, NOTE: When a call is received in DV mode when the
RXRPT1 and RXRPT2. power save function is activated, the call sign may not be
CALLER : The station call sign that made a call.
received correctly.
CALLED : The station call sign called by the caller.
RXRPT1 : The repeater call sign used by the caller station. This is normal, not a malfunction, because of header of the
RXRPT2 : The repeater call sign linked from RXRPT1. call sign cannot be detected during power save.
r Push [MENU/LOCK] to return to frequency indication. Turn the power save function OFF (p. 114) if you want to
receive a call sign correctly even in stand-by condition.

✔ For your information


When receiving a call, the received station call sign is auto-
matically displayed and scrolled in sequence at the bottom
line of the function display.
This can be turned OFF in display set mode. (p.100)
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
46
DV MODE OPERATION (Optional UT-121 is required) 7

D One-touch reply using the call record 1


The stored call signs in the call record can be used to the call. Important! 2
Setting call signs with the “One-touch reply using the call
qAfter receiving a call, push and hold [RX➝CS](CALL) for 3
record” operation as at left are for temporary operation only.
1 sec.
Therefore, the set call signs will be overwritten when an- 4
Or, while pushing and holding [RX➝CS](CALL), rotate
other call record is used to set call signs.
[DIAL] to select the desired call sign record. 5
• Never saved into a call sign memory.
-DUP
DV
6
B 439 706 25 If you want to save the set call signs, see “Copying the call
record contents into call sign memory” (p. 50) for details. 7
AAAAAA 8
✔ For your information
The received call sign is displayed while pushing and
When a call specifying your call sign is received, the call signs 9
holding [CALL/RX➝CS] when [DIAL] is rotated while
[CALL/RX➝CS] is pushed. of the calling station and the repeater it is using can be used 10
for operation automatically.
• Set your own call sign (MY) in advance. (p. 34) 11
• The call sign stored in “CALLER” is stored as “UR,” “RXRPT1” is • When “RX call sign auto write” (p. 93) is set to “AUTO,” the
stored as “R2” and “RXRPT2” is stored as “R1.” station call sign in “CALLER” is set to “UR” automatically.
12
• Error beeps sound when a call sign is received incorrectly, and 13
no call sign is set in this case. • When “Repeater call sign auto write” (p. 93) is set to “AUTO,”
wPush [PTT] to transmit; release to receive. the stored station call sign in “RXRPT1” is stored as “R2” 14
and “RXRPT2” is stored as “R1” automatically. 15
16
17
18
19
47
7 DV MODE OPERATION (Optional UT-121 is required)

■ Copying the call sign


D Copying the call sign memory contents • When “AUTO” is set to “EDIT RECORD” item
r Push [≈
≈](6) to select the call sign programming mode.
This function is convenient when or modifying a part of the
• A blank channel is selected automatically.
current call sign.
• The 1st digit of the selected call sign blinks.
NOTE: Make sure that the “EDIT RECORD” item in DV set YOUR CALL SIGN

mode is set to “AUTO” or “SELECT” in advance. (p. 95) rU21 AB A blank channel
†AAAAA number blinks.
qDuring DV mode operation, enter call sign set mode. :SET CLR:CLR
:SEL A/a:CHAR
MENU screen ➪ CALL SIGN :CUR 0:CQ

(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)


tEdit or modify the selected call sign as described in “D Sta-
• CALL SIGN screen is displayed. tion call sign programming” (p. 36) or “D Repeater call sign
wRotate [DIAL]† to select “UR,” “R1” or “R2” as desired, then programming” (p. 41).
push [ï](5)†. yPush [ï](5) to store the edited/modified call sign into the
eRotate [DIAL]† to select the desired call sign channel to be selected blank channel.
copied.
• U01–U60 and R01–R60 are available. NOTE: The message “FULL” is displayed when no blank
channel is available in station or repeater call sign mem-
ory.
Select the desired call sign channel number as described
in step u of “• When “SELECT” is set to “EDIT RECORD”
item” at right-hand page in this case.

48
DV MODE OPERATION (Optional UT-121 is required) 7

1
• When “SELECT” is set to “EDIT RECORD” item 2
r Push [≈
≈](6) to select the call sign programming mode.
• The 1st digit of the selected call sign blinks.
3
tEdit or modify the selected call sign as described in “D Sta- 4
tion call sign programming” (p. 36) or “D Repeater call sign
programming” (p. 41). 5
yPush [ï](5). 6
• Call sign channel number blinks.
YOUR CALL SIGN
7
rU21 AB Call sign channel
AAAAA1 number bliks.
8
:SET
:SEL
CLR:CLR
A/a:CHAR
9
:CUR 0:CQ
10
uRotate [DIAL]† to select the desired call sign channel to 11
store.
iPush [ï](5) to store the edited/modified call sign into the 12
selected channel.
13
14
15
16
17
18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
49
7 DV MODE OPERATION (Optional UT-121 is required)

D Copying the call record contents into call sign memory


This is a way to copying the call record contents (“CALLER,” • When “CALLER,” “RXRPT1” or “RXRPT2” is
“RXRPT1” and “RXRPT2”) into call sign memory (“UR,” “R1” and selected
“R2”) at the same time or individually. zPush [≈ ≈](6) then rotate [DIAL]† to select the desired con-
dition of call sign memory channel selection to be copied to
qPerform the steps q to e of “D Desired call record indica- from “AUTO” and “LIST SEL.”
tion” (p. 46) to select the desired call record or call sign. • “AUTO” selection won’t appear when the appropriate call sign
w Push [≈ ≈](6) to select copy select mode. memory has no blank channel.
• COPY SELECT screen is displayed. • Go to step r when “AUTO” is selected.
COPY SELECT
COPY SELECT
RX01 RX01
rALL
rAUTO

LIST SEL
:BACK :SEL
:BACK :SEL
:LIST C:CURR
:LIST

eRotate [DIAL]† to select the desired call sign to be copied xPush [≈


≈](6), then select the desired call sign memory
from “ALL,” “RXRPT1” and “RXRPT2.” channel to copy to with [DIAL].
• “ALL” selection won’t appear when either station or repeater call cPush [≈
≈](6) to copy the call sign into the selected call
sign memory has no blank channel.
sign memory.
• Returns to RX CALL SIGN screen automatically.
• When “ALL” is selected
➥ Push [≈
≈](6) to copy the selected record’s contents into r Push [MENU/LOCK] to return to frequency indication.
the appropriate call sign memory.
• Returns to RX CALL SIGN screen automatically.

†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
50
DV MODE OPERATION (Optional UT-121 is required) 7

■ Break-in communication • How to use the break-in? 1


The break-in function allows you to break into a conversation, While operating with the call sign squelch (p. 110), the 2
where the two original stations are communicating with call squelch never opens (no audio sounds) even if a call is re-
sign squelch enabled. ceived, unless your own call sign (“MY”) is specified. 3
However, when the call including the “BK ON” signal (break- 4
qWhile receiving an another station’s communication, push in call) is received, the squelch will open and audio sounds
and hold [RX➝CS](CALL) for 1 sec. to set the communi- even if the call is specified for another station. 5
cating station’s call sign. • Station C calling to Station A with “BK OFF”
• When a call sign has not been received correctly, error beeps
6
sound and no call sign is set. Receive the call sign of a commu- Station A and B are 7
nicating signal again, or set the call sign manually. communicating us-
wPush and hold [BK](9) for 1 sec. to turn the break-in func- ing the call sign
8
tion ON. squelch. 9
• “BK” appears. Station A Station B
10
DV BK Appears Station B never hears that
B 430 712 50 Station C is calling Station A. 11
LOW
Station C 12
ATT
• Station C calling to Station A with “BK ON” 13
eWhen both stations are in standby, push [PTT] to transmit
a break-in call. Station A and B are
14
• The programmed call sign station receives the break-in call as communicating us- 15
well as your call sign. ing the call sign
rWait for the reply call from the station who receives the squelch. 16
break-in call. Station A Station B
t After receiving the reply call, communicate normally.
17
yTo cancel the break-in, push and hold [BK](9) for 1 sec. to Station B also hears that Sta- 18
turn OFF. tion C is calling Station A.
Station C 19
51
7 DV MODE OPERATION (Optional UT-121 is required)

■ Message operation
D TX message programming
TX messages are available for up to 5 channels and each r Rotate [DIAL]† to select the desired character or symbol.
channel can be programmed with a message of up to 20 • Push [A/a](3) to change the character group from “AB” (alpha-
characters. Available characters are 0 to 9, A to Z (capital let- betical characters; capital letters), “ab” (alphabetical characters;
ters), a to z (lower case letters), some symbols and space. lower case letters), “12” (numbers) and “ !” ” (symbols) in se-
quence.
q Enter “TX MESSAGE” in message/position set mode. • If an un-necessary character is entered, push [≈ ≈](6) or [Ω
Ω](4) to
select the character, then push [CLR](1) to erase the selected
MENU screen ➪ MESSAGE/POSITION ➪ TX MESSAGE
character, or push and hold [CLR](1) for 1 sec. to erase all char-
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
acters following the cursor.
• TX MESSAGE screen is displayed. tPush [≈
≈](6) to select 2nd digit, then rotate [DIAL]† to select
wRotate [DIAL]† to select the desired transmit message the desired character or code.
channel. • Push [≈≈](6) to move the cursor right; push [Ω
Ω](4) to move the
• Ch01 to Ch05 and OFF are available. cursor left.
• Previously message is displayed if programmed. • 2nd digit blinks (1st digit stops blinking).
e Push [≈
≈](6) to select the message edit condition. y Repeat the steps r and t to enter the desired message.
• The 1st digit of the message blinks. • Up to 20-character messages can be set.
TX MESSAGE TX MESSAGE
rCh01 rCh01 !'
'
† Hello!†

:SET :SEL :SET CLR:CLR


:BACK :EDIT :SEL A/a:CHAR
CLR:CLR :CUR

u Push [ï](5) to store the message.


i Push [MENU/LOCK] to return to frequency indication.

52
DV MODE OPERATION (Optional UT-121 is required) 7

1
D Message Transmission 2
Select the message transmission function ON (Ch01–05) and ✔ For your information 3
OFF. When a message channel is selected, the transceiver The automatic received call sign and/or message indication
transmits a text message (pre-programmed). (default: OFF) can be turned OFF in display set mode, if desired. 4
➥ RX CALL SIGN (p. 100) 5
qSet the operating frequency, call signs and other settings, ➥ RX MESSAGE (p. 101)
such as repeater, as desired in B band. 6
wPerform the steps q to e in “D TX message program-
ming” as at left.
NOTE: Only 1 message can be stored in the IC-E91. The 7
received message is cleared by turning power OFF, or
eRotate [DIAL]† to select the desired message channel. 8
• “Ch01” to “Ch05” available.
overwritten when another message is received.
• See left-hand pages for message programming. A transmitted message that includes lower case charac- 9
rPush [ï](5) to set the message for transmission. ters from the IC-E91 may not be decoded and displayed
correctly by the ID-800H, IC-V82/U82, etc. 10
tPush [PTT] to transmit the selected message.
• The message is transmitted each time [PTT] is pushed. 11
• The message is transmitted each 30 sec. automatically during
continuous transmission. 12
y Release [PTT] to return to receive. 13
uWhen the reply call with a message is received, the call
sign and the message scrolls at the bottom of the function 14
display.
15
DV 16
B 430 712 50
17
MSG:Hello! 18
Scrolls the received message. 19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
53
7 DV MODE OPERATION (Optional UT-121 is required)

■ Automatic reply function


D RX message indication The automatic reply function replies to calls by a station that
The received message can also be checked in DV set mode. specified your call sign.

q Select “RX MESSAGE” in message/position set mode. Two methods of replying are available— one is making a
reply call with your own call sign, and other one is making a
MENU screen ➪ MESSAGE/POSITION ➪ RX MESSAGE
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
reply call with reply voice audio that has been recorded in DV
voice memory.
• The received message is displayed in RX MESSAGE screen.
RX MESSAGE
rMESSAGE:
D Automatic reply function setting
q Enter “AUTO REPLY” in DV set mode. (p. 92)
Hello!
MENU screen ➪ DV SET MODE ➪ AUTO REPLY
:BACK :CALLER (Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
• AUTO REPLY screen is displayed.
wRotate [DIAL] or push [√
√](8) to display the station call
w Rotate [DIAL]† to select the desired reply condition.
sign.
OFF : Deactivate the automatic reply function. (default)
RX MESSAGE
rCALLER:
ON : Reply to the call with your own call sign.
VOICE : Reply to the call with the recorded voice memory.
BBBBBB
AUTO REPLY
/ rOFF
:BACK :MSG
ON
VOICE
ePush [ï](5) or [Ω
Ω](4) to return to MESSAGE/POSITION
screen.
r Push [MENU/LOCK] to return to frequency indication.
e Push [ï](5).
• Returns to DV SET MODE screen automatically.
r Push [MENU/LOCK] to return to frequency indication.

54
DV MODE OPERATION (Optional UT-121 is required) 7

1
D Voice memory recording for automatic reply D Play-back or erase the voice memory 2
IMPORTANT! q Push [MENU/LOCK] to select menu mode indication. 3
Deactivate the dualwatch function and set minimum [VOL] wRotate [DIAL]† to select “DV VOICE MEMO,” then push
[ï](5)†. 4
level when recording the DV voice memo.
Otherwise received audio or unwanted noise from A band is eRotate [DIAL]† to select “REPLY VOICE,” then push 5
also recorded into the voice memory. [ï](5)†.
• REPLY VOICE screen is displayed. 6
rTo play-back the recorded voice memory, push [ï](5).
qSelect DV mode in B band, and deactivate the priority ≈](6) to cancel the play-back.
• Push [ï](5) again to pause, push [≈
7
watch (p. 83) if activated. tTo erase the recorded voice memory, push and hold 8
w Enter “REPLY VOICE” in DV voice memo set mode. [CLR](1) for 1 sec.
MENU screen ➪ DV VOICE MEMO ➪ REPLY VOICE 9
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
10
• REPLY VOICE screen is displayed.
11
REPLY VOICE
rREPLY V 12
13
: PTT: ●
:BACK CLR:CLR 14
eWhile pushing and holding [PTT], speak into the micro- 15
phone.
• Up to 10 seconds of message is recordable.
16
• The recording stops after 10 second or when [PTT] is released. 17
r Push [Ω
Ω](4) to return to DV VOICE MEMO screen.
t Push [MENU/LOCK] to return to frequency indication. 18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
55
7 DV MODE OPERATION (Optional UT-121 is required)

■ EMR communication ■ Low-speed data communication


The EMR communication mode is available for digital mode In addition to the digital voice communication, low-speed data
operation. In the EMR communication mode, no call sign set- communication is available.
ting is necessary. When an EMR communication mode sig- The optional OPC-1529R DATA COMMUNICATION CABLE and se-
nal is received, the audio (voice) will be heard at the specified rial data communication software (purchase locally) are re-
level even the volume setting level is set to minimum level, or quired in addition.
digital call sign/digital code squelch is in use.
The optional RS-91 REMOTE CONTROL SOFTWARE (OPC-1529R
qSet the desired frequency in 144 or 430 MHz band then supplied) also includes a low-speed data communication ca-
push and hold [EMR](.) until 3 short and 1 long beeps pability.
sound to turn the EMR setting ON.
• “EMR” appears NOTE: Turn OFF the GPS mode (p. 58) in advance to op-
erate the low-speed data communication.
DV EMR Appears
B 430 712 50 D Connection
Connect the transceiver to your PC using with the optional
OPC-1529R as illustrated below.
w Operate the transceiver normal way.
eTo cancel the EMR communication mode, push and hold
[EMR](.) for 1 sec. to turn OFF.

to [DATA] to
RS-232C

OPC-1529R
(optional)

56
DV MODE OPERATION (Optional UT-121 is required) 7

1
D Low-speed data communication application D Transmission condition setting 2
setting q Enter “DV DATA TX” in DV set mode. (p. 92) 3
Configure the low-speed data communication application as MENU screen ➪ DV SET MODE ➪ DV DATA TX
follows. (Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) 4
• Port : The same COM port number as IC-E91’s w Rotate [DIAL]† to select “PTT” or “AUTO.” 5
• Baud rate : 38.4 kbps (fixed value) ePush [ï](5) (or [Ω
Ω](4)) to return to DV set mode, and push 6
• Data : 8 bit [MENU/LOCK] to return to frequency indication.
• Parity : None 7
• Stop : 1 bit 8
• Flow control : Xon/Xoff
9
D Low-speed data communication operation 10
✔ For your information
NOTE: Confirm that in AUTO, the computer controls when While operating low-speed data communication via the inter- 11
[PTT] is activated to send data and the user doesn’t have net network from one zone to another zone, some packets
to operate the radio. may be lost due to the network trouble (poor data throughput
12
qSet your own, station call signs, etc. as described in performance). In such a case, the IC-E91 displays an “L” in 13
“■ Digital voice mode operation” (p. 38) and “■ Digital re- the upper right corner on the display to indicate Packet Loss
peater operation” (p. 41). has occured. 14
wRefer to the instructions of the low-speed data communi- 15
cation application. DV L Appears
e To transmit data B 430 712 50 16
• With your voice audio, push and hold [PTT] to transmit while 17
sending data from the PC. Release [PTT] to receive.
• Under computer control, see Transmission condition setting at 18
right.
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
57
7 DV MODE OPERATION (Optional UT-121 is required)

■ GPS operation
During GPS mode operation, a GPS receiver (RS-232C out- D Sentence formatter setting
put/NMEA format) can be connected to the [DATA] socket of q Enter “GPS MODE” in DV set mode. (p. 94)
the IC-E91 to indicate the current position (Latitude and Longi-
MENU screen ➪ DV SET MODE ➪ GPS MODE
tude). The position data is transmitted with your voice signals
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
at the same time.
• GPS MODE screen is displayed.
In addition, the GPS message transmission is also available GPS MODE
for the GPS mode operation. OFF
rON

:SENTENCE

to [DATA] GPS
to RS-232C port receiver w Rotate [DIAL]† to select “ON.”
(null modem e Push [ï](5)† to select GPS SENTENCE screen.
adapter is required)
rRotate [DIAL]† to select the desired GPS sentence, then
OPC-1529R push [ï](5).
(optional) • A total 5 sentences, RMC, GGA, GLL, GSA and VTG are avail-
able.
t Rotate [DIAL]† to turn the sentence usage ON and OFF.
yPush [ï](5) (or [Ω Ω](4)) to return to GPS SENTENCE
screen.
uRepeat the steps r to y to set another GPS sentence
usage.
• Up to 3 GPS sentences are usable at the same time.
i Push [MENU/LOCK] to return to frequency indication.

58
DV MODE OPERATION (Optional UT-121 is required) 7

1
D GPS message programming 2
q Enter “GPS” in message/position set mode. t Repeat the steps r and t to enter the desired message. 3
• Up to 20-character messages can be set.
MENU screen ➪ MESSAGE/POSITION ➪ GPS 4
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) GPS MESSAGE
rDATA: AB
• GPS MESSAGE screen is displayed. Hello!†
5
w Push [≈
≈](6) to select the message edit condition. :SET CLR:CLR 6
:SEL A/a:CHAR
• The 1st digit of the message blinks.
GPS MESSAGE
:CUR
7
rDATA: AB y Push [ï](5) to store the message. 8
† u Push [MENU/LOCK] to return to frequency indication.
:SET CLR:CLR 9
:SEL A/a:CHAR
:CUR
10
e Rotate [DIAL]† to select the desired character or symbol. 11
• Push [A/a](3) to change the character group from “AB” (alpha-
betical characters; capital letters), “ab” (alphabetical characters; 12
lower case letters), “12” (numbers) and “ !” ” (symbols) in se-
quence. 13
rPush [≈
≈](6) to select 2nd digit, then rotate [DIAL]† to select 14
the desired character or code.
• Push [≈≈](6) to move the cursor right; push [Ω
Ω](4) to move the 15
cursor left.
• 2nd digit blinks (1st digit stops blinking).
16
17
18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
59
7 DV MODE OPERATION (Optional UT-121 is required)

D GPS message automatic transmission D Position indication


q Enter “GPS AUTO TX” in DV set mode. (p. 95) q Enter “POSITION” in message/position set mode.
MENU screen ➪ DV SET MODE ➪ GPS AUTO TX MENU screen ➪ MESSAGE/POSITION ➪ POSITION
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) (Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
• GPS AUTO RX screen is displayed. • GPS POSITION screen is displayed.
GPS AUTO TX GPS POSITION
rOFF rMY POSITION
5SEC
10SEC 34.56.789 N
30SEC 123.45.678 E
1MIN :BACK :RX POS

wRotate [DIAL]† to select the desired position data transmit- wRotate [DIAL]† to select the received position data indica-
ting interval from 5 sec., 10 sec., 30 sec., 1 min., 3 min., tion.
5 min., 10 min., 30 min. and OFF. ePush [ï](5) (or [Ω
Ω](4)) to return to MESSAGE/POSITION
• The position data is transmitted only when [PTT] is pushed with screen.
OFF setting, the data is transmitted automatically once every r Push [MENU/LOCK] to return to frequency indication.
5 sec., 10 sec., 30 sec., 1 min., 3 min., 5 min., 10 min. and
30 min. when the appropriate setting is selected.
• The GPS message is also transmitted if programmed.
ePush [ï](5) (or [Ω Ω](4)) to return to DV SET MODE screen.
r Push [MENU/LOCK] to return to frequency indication.

NOTE: Your own call sign (“MY”) should be set to activate


the GPS automatic transmission.

60
DV MODE OPERATION (Optional UT-121 is required) 7

D Received GPS message indication 1


q Enter “RX GPS” in message/position set mode.
2
MENU screen ➪ MESSAGE/POSITION ➪ RX GPS
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) 3
• RX GPS MESSAGE screen is displayed. 4
RX GPS MESSAGE
rDATA: 5
Call from 6
Osaka!
:BACK
7
wPush [ï](5) (or [Ω
Ω](4)) to return to MESSAGE/POSITION 8
screen. 9
e Push [MENU/LOCK] to return to frequency indication.
10
11
12
13
14
15
16
17
18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
61
7 DV MODE OPERATION (Optional UT-121 is required)

■ Other functions for DV mode operation


D DV voice memory
The IC-E91 has a DV voice memory that records a total 30 ◆ Track size setting
second (approx.) of received audio. The track size can be changed with the following instruction.
The DV voice memory is divided into 2 tracks, 15 seconds
each in a track, as the default setting. q Enter “TRACK SIZE” in DV voice memo set mode.
MENU screen ➪ DV VOICE MEMO ➪ TRACK SIZE
◆ Recording received audio (Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
qSelect DV mode in B band, and deactivate the priority • TRACK SIZE screen is displayed
watch (p. 83) if activated. TRACK SIZE
w While receiving a DV signal, push [REC]. r10S/3TRACK

15S/2TRACK
DV 30S/1TRACK
B 430 012 50

qREC TRACK:2 w Rotate [DIAL]† to select the desired track size.


10S/3TRACK : Makes 3 tracks and 10 seconds audio
e Rotate [DIAL] to select the desired track. can be recorded in each track.
• “✱” is displayed beside the track number when the selected track 15S/2TRACK : Makes 2 tracks and 15 seconds audio
has been recorded.
can be recorded in each track.
r Push [REC] to start recording.
30S/1TRACK : Makes 1 track only and 30 seconds audio
• Track counter (bar meter) is displayed during record.
• The recording is paused automatically when the DV signal is in-
can be recorded in a track.
terrupted or when the DV audio signal cannot be received cor- ePush [ï](5) (or [Ω Ω](4)) to return to DV VOICE MEMO
rectly. Re-starts the recording when the DV audio signal is screen.
received correctly. r Push [MENU/LOCK] to return to frequency indication.
t Push [REC] again to stop recording.
• The recording stops automatically when the track becomes full.

62
DV MODE OPERATION (Optional UT-121 is required) 7

D DV automatic detect 1
◆ Playing-back and erasing the recorded audio The “DV” mode indicator blinks when a non-DV signal is re-
qSelect DV mode in B band, and deactivate the priority ceived during DV mode operation.
2
watch (p. 83) if activated. The IC-E91 DV automatic detection monitors in FM mode 3
w Enter “TRACK” in DV voice memo set mode. when other than DV mode signal is received.
MENU screen ➪ DV VOICE MEMO ➪ TRACK
4
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) q Enter “AUTO DETECT” in DV set mode. (p. 95) 5
MENU screen ➪ DV SET MODE ➪ AUTO DETECT
• TRACK screen is displayed 6
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
TRACK
rTRACK:1 * wRotate [DIAL]† to turn the DV automatic detect function ON 7
and OFF.
OFF : “DV” mode indicator blinks, however the trans-
8
:SEL :
:BACK CLR:CLR ceiver receives in DV mode even if non-DV mode 9
signals are received.
eRotate [DIAL]† to select the desired audio track to be play- ON : “DV” mode indicator blinks and the transceiver
10
back or erased.
• “✱” is displayed beside the track number when the selected track
monitors the signal in FM mode. 11
ePush [ï](5) (or [Ω
Ω](4)) to return to DV SET MODE screen
has been recorded.
r Push [MENU/LOCK] to return to frequency indication. 12
rPush [ï](5) to play-back the recorded audio.
≈](6) to stop play-back.
• Push [ï](5) again to pause, push [≈ 13
tPush and hold [CLR](1) for 1 sec. to erase the recorded NOTE: The received FM audio may be distorted when re-
14
audio. ceiving an FM signal with DV automatic detect function.
y Push [ΩΩ](4) to return to DV VOICE MEMO screen. 15
u Push [MENU/LOCK] to return to frequency indication.
16
17
18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
63
8 MEMORY/CALL CHANNELS

■ General description ■ Selecting a memory channel


The IC-E91 has 850 memory channels in A band, 450 mem- D Using [DIAL]— Programmed channels
ory channels in B band, and 2 call channels in each band. qPush [MR] to select memory mode.
Memory channels in each bands including 50 scan edge wRotate [DIAL] to select the desired memory channel.
memory channels (25 pairs) for storage of often-used frequen- • Only programmed channels are displayed.
cies, respectively.
[DIAL]
And a total of 26 memory banks, A to Z, are available in each
bands for storing groups of frequencies, etc. Up to 100 chan- FM

nels can be assigned into a bank.


A
145 000 Appears
µ 000
D Memory channel contents
The following information can be programmed into memory
channels: Rotate [DIAL] to select
the memory channel.
• Operating frequency (p. 18)
• Operating mode (p. 21)
• Duplex direction (+DUP or –DUP) with an offset frequency
(p. 32) D Using [DIAL]— All channels
• Subaudible tone encoder (p. 107), tone squelch or DTCS qPush [MR] to select memory mode.
squelch ON/OFF (p. 110) wPush and hold [S.MW](MR) for 1 sec. to enter select mem-
• Subaudible tone frequency (p. 107), tone squelch fre- ory write mode.
quency or DTCS code with polarity (pgs. 107, 111) • 1 short and 1 long beep sound.
• Scan skip information (p. 80) µ ” indicator blinks.
• “µ
• Memory bank (p. 67) eRotate [DIAL] to select the desired memory channel.
• Memory name (p. 70) • All channels are displayed.
• Tuning step (p. 18) • Push [VFO] to return to memory mode indication.
• Call sign squelch or Digital code squelch* (p. 110)
• Station call sign* (p. 36)
• RPT1/RPT2 call sign* (p. 41)
*Available for B band operation only.
64
MEMORY/CALL CHANNELS 8

■ Selecting a call channel 1


[DIAL] qPush [CALL] to select call channel mode. 2
FM Blinks • Pushing [CALL] toggles call, TV* channels.
r 145 000 µ 000 wRotate [DIAL] to select the desired call channel.
3
BANK :----
• “C0” and “C1” are selectable. 4
MNAME:
SKIP :OFF
*Appears only when TV channels are programmed via the 5
optional RS-91. Also available for A band operation only.
Rotate [DIAL] to select 6
the memory channel. [DIAL] VHF band call channel 7
FM
8
D Using the KEYPAD A
145 000
qPush [MR] to select memory mode. 9
C0
wPush the keypad to enter 3 digits to select the desired 10
memory channel.
• The blank channels are also selectable. UHF band call channel 11
FM
12
• Example— selecting memory channel “25” A
430 000
Push [MR] then push [0], [2], [5]. 13
C1
14
FM
A
145 600 15
Appears
µ 025
16
Keypad
17
The entered memory 18
channel is selected.
19
65
8 MEMORY/CALL CHANNELS

■ Memory channel programming


q Push [VFO] to select VFO mode. [EXAMPLE]: Programming 145.870 MHz into memory chan-
w Set the desired frequency: nel 11 (blank channel).
➥ Select the desired band with [BAND].
Push and hold
➥ Set the desired frequency with [DIAL].
➥ Or set the desired frequency with keypad directly. VFO mode for 1 sec. to program.
In this case, the band and frequency settings with FM FM

[BAND] and [DIAL] as above are not required.


A
145 870 A
145 870
PSKIP PSKIP

➥ Set other data (e.g. offset frequency, duplex direction, µ 011

tone squelch, etc.), if desired.


ePush and hold [S.MW](MR) for 1 sec. to enter select mem- Push
ory write mode. for 1 sec.
• 1 short and 1 long beep sound. Enter select memory Return to the VFO mode.
µ ” indicator blinks.
• “µ write mode. FM

r Rotate [DIAL] to select the desired channel. r


FM
145 000 µ 000
A
145 870
PSKIP
BANK :----
• Call channels (C0, C1), VFO (VFO) and scan edge channels
(0A/0B to 24A/24B), as well as regular memory channels, can MNAME:
SKIP :OFF
be programmed in this way.
t Push and hold [S.MW](MR) for 1 sec. to program. [DIAL]
• 3 beeps sound.
• Memory channel number automatically increases when contin- Rotate [DIAL] to select
uing to push and hold [S.MW](MR) for 3 sec. after programming. channel 11.
r µ 011
BANK :----

MNAME:
SKIP :OFF

Channel 11

66
MEMORY/CALL CHANNELS 8

■ Memory bank setting 1


The IC-E91 has a total of 26 banks (A to Z). Regular memory rPush [Ω
Ω](4) or [≈
≈](6) several times to select the desired 2
channels, 000 to 799 (A band)/000 to 399 (B band), are as- bank group from “A” to “Z.”
signed to the desired bank for easy memory management.
3
4
qPush and hold [S.MW](MR) for 1 sec. to enter select mem- 145 870 µ 011
ory write mode. r BANK :C-00 5
• 1 short and 1 long beep sound.
MNAME: 6
µ ” indicator blinks.
• “µ
SKIP :OFF
w Rotate [DIAL] to select the desired memory channel. 7
ePush [∫∫](2) or [√
√](8) to select “BANK.” Bank group is selected
• Bank group and channel number is displayed if the selected mem-
8
with or .
ory channel has already been previously assigned to a bank. 9
[DIAL] FM
10
r 145 870 µ 011
tRotate [DIAL] to select the bank channel number from “00”
BANK :----
to “99.” 11
MNAME: • Only vacant bank channel numbers will be displayed. 12
SKIP :OFF
145 870 µ 011
13
Push or r BANK :C-05
14
MNAME:
145 870 µ SKIP :OFF 15
011
r BANK :----
Bank channel is selec-
16
MNAME: ted with [DIAL]. 17
SKIP :OFF
yPush and hold [S.MW](MR) for 1 sec. to assign the chan- 18
nel to the bank.
• Return to the previous indication.
19
67
8 MEMORY/CALL CHANNELS

■ Memory bank selection


qPush [MR] several times to select memory bank mode. eRotate [DIAL] to select the bank channel.
wWhile pushing and holding [BAND], rotate [DIAL] to select • Only programmed channels are displayed.
the desired bank (A to Z). [DIAL]
• Only programmed banks are displayed.
Memory mode Memory bank mode
[DIAL]
FM

145 620
FM

145 870
A
A

µ 011 µ C01

Memory channel is Bank channel is selec-


displayed. ted with [DIAL].

Memory bank mode rPush [MR] to return to regular memory condition.


FM
A
145 870
µ C05

Bank channel is
displayed.

68
MEMORY/CALL CHANNELS 8

■ Programming memory/bank/scan name 1


Each memory channel can be programmed with an alphanu- • Push [≈≈](6) to move the cursor right; push [Ω Ω](4) to move the 2
meric channel name for easy recognition and can be indi- cursor left.
cated independently by channel. Names can be a maximum • Push [CLR](1) to erase the selected character, or push and hold 3
of 8 characters. [CLR](1) for 1 sec. to erase all characters following the cursor. 4
yRepeat step t until the desired channel name is pro-
NOTE: Scan name indication can be turned ON or OFF in 5
grammed.
display set mode. (p. 101)
uPush and hold [S.MW](MR) for 1 sec. to program the name 6
q Push [MR] to select memory mode. and exit channel name programming.
• When programming a call channel name, push [CALL] to select • 3 beeps sound. 7
call channel mode.
NOTE: Only one bank name can be programmed into 8
w Rotate [DIAL] to select the desired memory channel.
• Select scan edge channels (0A/0B to 24A/24B) for programming each bank. Therefore, the previously programmed bank 9
a scan name. name will be displayed when bank name indication is se-
ePush and hold [S.MW](MR) for 1 sec. to enter select mem- lected. Also, the programmed bank name is assigned for 10
ory write mode. the other bank channels automatically. 11
• 1 short and 1 long beep sound.
µ ” indicator blinks.
• “µ D Available characters 12
rPush [∫
∫](2) or [√
√](8) several times to select “BNAME,” 13
“MNAME” or “SNAME” when programming the bank name, ABCDEFGHIJKLMNOPQRSTUVWXYZ
the memory name or the scan name, respectively. abcdefghijklmnopqrstuvwxyz 14
• After selecting the name to be programmed, a cursor blinks for 0123456789 15
the first character. ! '' # $ % & ' ( ) * + , - . / : ; < = > ? @ [ \ ]
tRotate [DIAL] to select the desired character. ^ _ ` { | } ~ (Space)
16
• The selected character blinks. 17
• Push [A/a](3) to change the character group from “AB” (alphabeti-
cal characters; capital letters), “ab” (alphabetical characters; lower 18
case letters), “12” (numbers) and “ !” ” (symbols) in sequence.
19
69
8 MEMORY/CALL CHANNELS

[EXAMPLE]: Programming the bank name “AIR” into the


scan edge channel 03A.
■ Selecting memory/bank name
Push Push or indication
to select memory mode. to select BNAME *. During memory mode operation, either the programmed
FM
AM
127 500 µ memory name or bank name can be displayed below the fre-
145 870
03A
A
BANK :A-01 quency indication.
r BNAME:A
µ 011 MNAME:
SNAME: NOTE: The programmed scan name is displayed during
the programmed scan edge channel selection.

Rotate [DIAL] to select Rotate [DIAL] to enter q Push [MR] to select memory mode.
scan edge channel 03A. A , push . wWhile pushing [M.N](6), rotate [DIAL] to select display in-
AM
dication type from bank name, memory name and OFF.
A
127 500 AM
127 500 µ 03A Name indication OFF.
BANK :A-01
µ 03A r BNAME:AI FM

MNAME:
SNAME:
A
127 500
Push µ 03A
for 1 sec.
Enter select memory Enter I and R
write mode. with [DIAL] and . Memory name indication
AM
r 127 500 µ 03A
AM FM

BANK :A-01
127 500 µ 03A [DIAL] A
127 500
BNAME: BANK :A-01
rBNAME:AIR Airport1
MNAME: µ 03A
SNAME: MNAME:
SNAME:

Scan edge channel 03A


Bank name indication
*Select Push and hold FM

when programming the mem- for 1 sec. to program.


A
127 500
ory name or the scan name, AIR
µ 03A
respectively.
70
MEMORY/CALL CHANNELS 8

■ Copying memory/call contents 1


This function transfers a memory channel’s contents to VFO Holding [S.MW](MR) for 2 sec. at the step w, will also 2
(or another memory/call channel). This is useful when search- copy the memory contents to VFO. In this case, the steps
ing for signals around a memory channel frequency and for e and r are not necessary.
3
recalling the offset frequency, subaudible tone frequency etc. 4
D Memory/call➪memory/call
D Memory/call➪VFO 5
q Select the memory (call) channel to be copied.
q Select the memory (call) channel to be copied. ➥ Push [MR] or [CALL] to select memory mode or call 6
➥ Push [MR] or [CALL] to select memory mode or call channel mode, then rotate [DIAL] to select the desired 7
channel mode, then rotate [DIAL] to select the desired memory channel.
channel. wPush and hold [S.MW](MR) for 1 sec. to enter select mem- 8
wPush and hold [S.MW](MR) for 1 sec. to enter select mem- ory write mode.
ory write mode. • 1 short and 1 long beep sound.
9
• 1 short and 1 long beep sound. µ ” indicator blinks.
• “µ 10
µ ” indicator blinks.
• “µ • Do not hold [S.MW](MR) for more than 2 sec. otherwise the
e Rotate [DIAL] to select “VFO.” memory contents will be copied to VFO.
11
rPush and hold [S.MW](MR) for 1 sec. to write the selected e Rotate [DIAL] to select the target memory (call) channel. 12
channel contents to VFO mode. r Push and hold [S.MW](MR) for 1 sec. again to copy.
• Returns to VFO mode automatically. 13
[EXAMPLE]: Copying memory channel 11 to VFO. 14
During memory mode, 15
rotate [DIAL] to select Rotate [DIAL] to select
memory channel 11 . Push VFO . Push 16
FM FM

A
FM

145 870
for 1 sec. r 145 870 µ 011 145 000 µ VFO for 1 sec. FM
A
145 870
17
BANK :----

µ 011 MNAME:
PSKIP
18
SKIP :OFF

VFO is selected.
19
71
8 MEMORY/CALL CHANNELS

■ Memory clearing
Contents of programmed memories can be cleared (blanked), VFO mode
Push or
if desired. FM
A
145 870 to select CLEAR .
qPush and hold [S.MW](MR) for 1 sec. to enter select mem- PSKIP
145 000 µ 005
ory write mode.
MNAME:
• 1 short and 1 long beeps sound. SKIP :OFF
Push
µ ” indicator blinks.
• “µ rCLEAR

• Do not hold [S.MW](MR) for more than 2 sec. otherwise the for 1 sec.
Enter select memory
memory contents will be copied to VFO.
write mode.
wRotate [DIAL] to select the desired memory channel to be FM

cleared. r 145 000 µ 000 Push


BANK :----
ePush [∫∫](2) or [√
√](8) to select “CLEAR.” for 1 sec. to clear.
MNAME:
r Push and hold [S.MW](MR) for 1 sec. to clear the contents. SKIP :OFF r µ 005

• 3 beeps sound. BANK :----

• The cleared channel changes to blank channel MNAME:


SKIP :OFF
• Return to select memory write mode.— “µ µ ” indicator blinks.
Rotate [DIAL] to select
Push [VFO] to exit select memory write mode.
the desired channel.
NOTE: Be careful!— the contents of cleared memories r 145 000 µ 005
BANK :---- Push .
CANNOT be recalled.
MNAME: FM

145 870
SKIP :OFF A

PSKIP

Return to the VFO mode.

72
MEMORY/CALL CHANNELS 8

■ Erasing/transferring bank contents 1


The bank contents of programmed memory channels can be ePush [∫
∫](2) or [√
√](8) to select “BANK.” 2
cleared or reassigned to another memory bank. rPush [≈
≈](6) or [Ω
Ω](4) several times to select the desired
bank group to be transferred. 3
INFORMATION: Even if the memory bank contents are
cleared, the memory channel contents still remain pro-
• Select “– – – –” indication when erasing the contents from the 4
bank.
grammed. t Rotate [DIAL] to select the desired bank channel. 5
• Skip this step when “– – – –” indication is selected in step r. 6
qSelect the desired bank contents to be transferred or
To transfer the bank contents
erased from the bank. (p. 68) [DIAL] 7
to ch 11 in Bank B.
➥ Push [MR] several times to select memory bank mode. FM
➥ While pushing [BAND], rotate [DIAL] to select the de- 145 600 µ 025 8
sired memory bank group. r BANK :B-11
➥ Rotate [DIAL] to select the bank channel. BNAME: 9
MNAME:
[DIAL] FM
SKIP :OFF 10
FM
A
433 000 Bank channel is 11
A
433 000 µ 001 displayed.
12
µ C05 To erase
FM 13
145 600 µ 025
r BANK :---- 14
BNAME:
MNAME: 15
FM
SKIP :OFF
wPush [S.MW](MR) for 1 sec. to enter select memory write A
433 000 16
is displayed.
mode.
• 1 short and 1 long beeps sound. µ C05
17
yPush [S.MW](MR) for 1 sec. to erase/transfer the bank
• Displays the original memory channel number automatically and
contents. 18
µ ” indicator blinks.
“µ
• Do not hold [S.MW](MR) for more than 2 sec., otherwise the 19
memory contents will be copied to VFO.
73
9 SCAN OPERATION

■ Scan types
Scanning searches for signals automatically and makes it There are 7 scan types and 4 resume conditions to suit your
easier to locate new stations for contact or listening purposes. operating needs.

FULL SCAN (p. 75) Repeatedly scans all frequen- SELECTED BAND SCAN Repeatedly scans all frequen-
cies over the entire band. (p. 75) cies over the entire selected
495 999.990
kHz MHz Band Band band.
Some frequency ranges are edge edge
Scan not scanned according to the Scan
Jump
frequency coverage of the
Jump
transceiver’s version.

PROGRAMMED SCAN Repeatedly scans between MEMORY (SKIP) SCAN Repeatedly scans memory
(p. 75) two user-programmed fre- (p. 77) channels except those set as
Band Scan edges Band quencies. Used for checking SKIP skip channel. Skip channels
edge xxA xxB edge
for frequencies within a speci- M1 M2 M3 can be turned ON and OFF
Scan
fied range such as repeater M0 M4
by pushing and holding
output frequencies, etc. SKIP
[SKIP](5) in memory mode.
Jump M 199 M6 M5

ALL/SELECTED BANK Repeatedly scans all bank FREQUENCY/MEMORY Skips unwanted frequencies
SCAN (p. 78) channels or selected bank SKIP FUNCTION (p. 79) or channels that inconve-
SKIP channels. The skip scan is Band Band niently stop scanning. This
A00 A01 A02 also available. edge edge function can be turned ON
A99 A03 Scan and OFF by pushing and
SKIP SKIP SKIP
holding [SKIP](5) in either
A98 A05 A04 Jump
VFO or memory mode.
74
SCAN OPERATION 9

■ Full/band/programmed scan 1
q Push [VFO] to select VFO mode. r To start the scan, release [SCAN](2). 2
• Select the desired frequency band with [BAND], if desired. • Scan pauses when a signal is received.
w Set the squelch level. • Rotate [DIAL] to change the scanning direction, or resumes 3
eWhile pushing and holding [SCAN](2), rotate [DIAL] to se- manually.
• Push [VFO] to stop the scan.
4
lect the desired scanning type.
• “ALL” for full scan; “BAND” for band scan, “PROG-xx (or scan • During full/band scan • During programmed scan
5
name if programmed)” for programmed scan (xx= 0 to 24; pro-
grammed scan edges numbers are only displayed), “DUP” (ap- FM FM
6
pears only when duplex operation is set) for duplex scan.
A
148 800 A
148 800 7
P SKIP P SKIP
P01 8
[DIAL] • Full scan selection
FM 9
A
145 000 10
P SKIP
About the scanning steps: The selected tuning step in
each frequency band (in VFO mode) is used during scan. 11
SCAN:ALL
FM Duplex scan function: Repeatedly scans two frequencies 12
148 800
•ABand scan selection (transmission/reception) during duplex scan operation.
13
P SKIP

SCAN:BAND Scan name selection 14


FM
15
148 800
FM FM
•AProgrammed scan selection A
148 800 A
148 800 16
P SKIP
P SKIP P SKIP
P01
SCAN:PROG-01
SCAN:SCANNAME
17
Selectable between “ 00” to “24” 18
if programmed. Scan name Scan edge number
Scan name is not displayed during a programmed scan. 19
75
9 SCAN OPERATION

■ Scan edges programming


Scan edges can be programmed in the same manner as t Push and hold [S.MW](MR) for 1 sec.
memory channels. Scan edges are programmed into scan • 3 beeps sound.
edges, 00A/00B to 24A/24B, in memory channels. • The other scan edge channel “B,” 00B to 24B, is automatically
selected when continuing to push [S.MW](MR) after program-
q Push [VFO] to select VFO mode. ming.
w Set the desired frequency: yTo program a frequency for the other pair of scan edges,
➥ Select the desired band with [BAND]. 00B to 24B, repeat steps w and r.
➥ Set the desired frequency with [DIAL]. • If the same frequency is programmed into a pair of scan edges,
➥ Set other data (e.g. offset frequency, duplex direction, tone programmed scan will not function.
squelch, etc.), if desired.
ePush and hold [S.MW](MR) for 1 sec. to enter the select [DIAL]
memory write mode.
• 1 short and 1 long beeps sound.
µ ” indicator blinks.
• “µ
rRotate [DIAL] to select the desired programmed scan
edge channel from 00A to 24A.

[EXAMPLE]: Programming 145.300 MHz into scan edges 03A.

Push for 1 sec. Rotate [DIAL] Push for 1 sec.

FM FM
FM
145 000 µ FM FM

145 300 145 300 145 300


r 001 r µ 03A
A A A
BANK :---- BANK :----
P SKIP P SKIP P SKIP
MNAME: MNAME: 03A
SKIP :OFF SNAME:

76
SCAN OPERATION 9

■ Memory scan 1
IMPORTANT!: To perform memory scan, 2 or more mem- r Release [SCAN](2) to start the selected scan. 2
ory channels MUST be programmed, otherwise the scan • Scan pauses when a signal is received.
will not start. • Rotate [DIAL] to change the scanning direction, or resumes 3
manually.
qPush [MR] to select memory mode. 4
t To stop the scan, push [VFO].
w Set the squelch level. 5
eWhile pushing and holding [SCAN](2), rotate [DIAL] to se- • During memory scan
lect the desired scanning type. FM 6
• “ALL” for full memory scan; “BAND” for band memory scan, A
148 800 7
“MODE” for mode scan, “DUP” (appears only when duplex oper-
ation is set) for duplex scan. µ 012
8
[DIAL] • All memory scan selection 9
Band memory scan function: Repeatedly scans all 10
FM
memory channels programmed with any frequencies of the
A
145 000 band programmed in the memory channel selected for 11
P SKIP
µ 088 scanning. 12
SCAN:ALL
Mode scan function: Repeatedly scans all memory chan-
FM
nels in which the same operating mode as the selected 13
148
•ABand 800
memory scan selection
memory channel has been programmed. 14
P SKIP
µ 088 Duplex scan function: Repeatedly scans two frequencies
SCAN:BAND (transmission/reception) during duplex scan operation.
15
FM 16
148 800
•AMode scan selection
17
P SKIP
µ 088
SCAN:MODE 18
19
77
9 SCAN OPERATION

■ Memory bank scan


IMPORTANT!: To perform memory bank scan, 2 or more r Release [SCAN](2) to start the selected scan.
bank channels MUST be programmed, otherwise the scan • Scan pauses when a signal is received.
will not start. • Rotate [DIAL] to change the scanning direction, or resumes
manually.
qPush [S.MW](MR) several times to select memory bank
t To stop the scan, push [VFO].
mode.
w Set the squelch level. • During all bank/bank link scan • During bank scan
eWhile pushing and holding [SCAN](2), rotate [DIAL] to se- FM FM

lect the desired scanning type. A


148 800 A
148 800
• “ALL” for all bank scan; “BANK-LINK” for bank link scan or
“BANK-x” for bank scan (x= A to Z; programmed bank groups µ 888 µ A88
are only displayed.), “DUP” (appears only when duplex opera-
tion is set) for duplex scan.
The bank-link setting can be changed in scan set mode.
[DIAL] • All bank scan selection See page 97 for details.
FM
A
145 000 Duplex scan function: Repeatedly scans two frequencies
(transmission/reception) during duplex scan operation.
P SKIP
µ A01
SCAN:ALL
FM

148 800
•ABank link scan selection
P SKIP
µ A01
SCAN:BANK-LINK
FM

148 800
•ABank scan selection
P SKIP
µ A01
SCAN:BANK-A

Selectable between “A” to “Z”


if programmed.
78
SCAN OPERATION 9

■ Skip channel/frequency setting 1


Memory channels can be set to be skipped for memory skip ePush [∫
∫](2) or [√
√](8) several times to select “SKIP.” 2
scan. In addition, memory channels can be set to be skipped
for both memory skip scan and frequency skip scan. These FM
3
are useful to speed up the scan rate. r 145 870 µ 020 4
BANK :----
q Select a memory channel: 5
MNAME:
➥ Push push [MR] to select memory mode.
➥ Rotate [DIAL] to select the desired channel to be a skip
SKIP :OFF 6
channel/frequency. Push or 7
[DIAL] several times.
8
FM FM
145 870 µ 9
A
145 870 020

µ 020 MNAME: 10
r SKIP :OFF
CLEAR 11
rRotate [DIAL] to select the skip condition from “SKIP,”
12
“P SKIP” or “OFF” for the selected channel. 13
wPush and hold [S.MW](MR) for 1 sec. to enter select mem- • P SKIP: The channel is skipped during memory/bank scan and
ory write mode. the programmed frequency is skipped during VFO scan, 14
such as programmed scan.
• SKIP : The channel is skipped during memory or bank scan.
15
• OFF : The channel is scanned during any scan. 16
(Continue to the next page.)
17
18
19
79
9 SCAN OPERATION

tPush and hold [S.MW](MR) for 1 sec. to store the skip con- ✔ CONVENIENT!
dition into the memory. During VFO scanning, such as programmed scan, the skip
• “SKIP” or “P SKIP” indicator appears, according to the skip se-
setting can be programmed into the highest blank memory
lection in the step r.
channel which is automatically selected with the following op-
• Skip channel setting • Program skip setting eration.
FM FM
q Start the VFO scan.
A
145 700 A
145 700 ➥ Push [VFO] to select VFO mode.
SKIP P SKIP • Select the desired frequency band with [BAND], if desired.
µ 033 µ 033
➥ Set the squelch level.
➥ While pushing and holding [SCAN](2), rotate [DIAL] to
“SKIP” appears “P SKIP” appears select the desired scanning type.
• “ALL” for full scan; “BAND” for band scan, “PROG-xx (or scan
name if programmed)” for programmed scan (xx= 0 to 24;
programmed scan edges numbers are only displayed), “DUP”
✔ CONVENIENT! for duplex scan.
The the skip setting can be set with the following operation. ➥ To start the scan, release [SCAN](2).
qSelect the desired memory channel to be set as a skip • Scan pauses when a signal is received.
channel/frequency. • Rotate [DIAL] to change the scanning direction, or resumes
manually.
wWhile pushing [SKIP](5), rotate [DIAL] to select the skip con-
wWhen scan pauses and you want to set the paused fre-
dition from “P SKIP,” “SKIP” and “OFF (no indication).”
quency as a skip frequency.
➥ Push and hold [SKIP](5) for 1 sec. to store the paused
frequency into the highest blank memory channel.
• While pushing and holding [SKIP](5), rotate [DIAL] to select a
skip condition from “SKIP,” “P SKIP” and “OFF.”
• While pushing and holding [SKIP](5), scan pauses; and after
writing the frequency, scan resumes.

80
SCAN OPERATION 9

■ Scan resume condition 1


D Scan pause timer D Scan resume timer 2
The scan pauses when receiving signals according to the The scan restarts after the signal disappears according to the
scan pause time. It can be set from 2 to 20 sec. or unlimited. resume time. It can be set from 0–5 sec. or unlimited.
3
q Enter “PAUSE” in scan set mode. (p. 96) q Enter “RESUME” in scan set mode. (p. 96)
4
MENU screen ➪ SCAN ➪ PAUSE MENU screen ➪ SCAN ➪ RESUME 5
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) (Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
6
w Rotate [DIAL]† to set the desired scan pausing time from w Rotate [DIAL]† to set the desired scan resume time from
2–20 sec. (2 sec. steps) or “HOLD.” 0–5 sec. (1 sec. steps) and “HOLD.” 7
• “2SEC”–“20SEC”: Scan pauses for 2–20 sec. while receiving a • “0SEC” : Scan restarts immediately after the signal 8
signal. disappears.
• “HOLD” : Scan pauses on a received a signal until it • “1SEC”–“5SEC” : Scan restarts 1–5 sec. after the signal disap- 9
disappears. pears.
e Push [ï](5) (or [Ω
Ω](4)) to return to scan set mode. • “HOLD” : Scan restarts by rotating [DIAL] only. 10
r [MENU/LOCK] to return to frequency indication. e Push [ï](5) (or [Ω
Ω](4)) to return to scan set mode. 11
• Pause timer setting r [MENU/LOCK] to return to frequency indication.
PAUSE TIMER • Resume timer setting 12
4SEC
6SEC
RESUME TIMER 13
1SEC
8SEC
r10SEC
r 2SEC 14
3SEC
12SEC 4SEC 15
5SEC
16
Scan resume timer must be set shorter than the scan
pause timer, otherwise this timer does not activate. 17
18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
81
10 PRIORITY WATCH

■ Priority watch types


Priority watch checks for signals on the frequency every
5 sec. while operating on a VFO frequency or scanning. The
MEMORY/CALL CHANNEL WATCH
While operating on a VFO fre- 5 sec.
transceiver has 3 priority watch types to suit your needs.
quency, priority watch checks for
a signal on the selected every 5 Memory
The watch resumes according to the selected scan resume VFO
(Call)
condition. See page 81 for details. sec. frequency
channel
• A memory channel with skip infor-
NOTE: If the pocket beep function is activated, the trans- mation can be watched.
ceiver automatically selects the tone squelch function
when priority watch starts.
MEMORY SCAN WATCH
D About priority beep function While operating on a VFO fre- 5 sec.
When receiving a signal on the priority frequency, you can be quency, priority watch checks for Mch 000
SKIP Mch 001
alerted with beeps and a blink “S.” This function can be signals on each memory chan- VFO
frequency Mch 001
activated when setting the priority watch function ON. nel in sequence.
• The memory skip function and/or Mch 999
memory bank scan is useful to
speed up the scan.

VFO SCAN WATCH


While scanning in VFO mode, 5 sec.
priority watch checks for signals
on the selected every 5 sec. Memory
VFO
(Call)
scan
channel

82
PRIORITY WATCH 10

■ Priority watch operation 1


Although [DIAL] and [ï](5) are used for description in this • During priority watch
2
∫](2)/[√
section, [∫ √](8) and [≈
≈](6) are available instead of
FM PRIO FM PRIO
3
[DIAL] and [ï](5). A
433 260 A
145 180 4
D Memory/call channel and memory scan watch P SKIP
µ 035 5
q Select VFO mode; then, set an operating frequency.
w Set the watching channel(s). Monitors VFO frequency Pauses on a memory or
6
For memory channel watch: for 5 sec. call channel when a sig-
Select the desired memory channel.
7
nal is received.
For call channel watch: 8
Select the desired call channel.
For memory scan watch:
• During priority watch with priority beep 9
Select memory mode, or the desired bank group; then, FM PRIO FM PRIO
10
push and hold [SCAN](2) for 1 sec. to start memory/bank
A
433 260 A
145 180
scan. P SKIP
11
µ 035
e Enter “PRIO WATCH” in scan set mode. (p. 96) 12
MENU screen ➪ SCAN ➪ PRIO WATCH
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
Emits beep and blinks “S” indicator when a signal is re- 13
ceived on a memory or call channel.
r Rotate [DIAL]† to select “ON.” 14
• Select “BELL” if the priority beep function is desired. 15
t Push [MENU/LOCK] to exit scan set mode and start the
watch. 16
• “PRIO” indicator appears.
• The transceiver checks the memory/bank channel(s) or call
17
channel every 5 sec. 18
• The watch resumes according to the selected scan resume con-
dition. (p. 81) 19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
y Push [VFO] to cancel the watch.
83
10 PRIORITY WATCH

D VFO scan watch


q Set the watching channel(s). i Push [VFO] to cancel the watch.
For memory channel watch: • During priority watch
Select the desired memory channel.
For call channel watch: FM PRIO FM PRIO

Select the desired call channel.


A
888 800 A
145 000
For memory scan watch: P SKIP
µ 000
Select memory mode, or the desired bank group; then,
push and hold [SCAN](2) for 1 sec. to start memory/bank Searches VFO frequencies Pauses on a memory or
scan. for 5 sec. call channel when a sig-
w Enter “PRIO WATCH” in scan set mode. (p. 96) nal is received.
MENU screen ➪ SCAN ➪ PRIO WATCH
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
• During priority watch with priority beep
e Rotate [DIAL]† to select “ON.” FM PRIO FM PRIO
• Select “BELL” if the priority beep function is desired.
r Push [VFO] to exit scan set mode and start the watch.
A
888 800 A
145 000
P SKIP
• “PRIO” indicator appears. µ 000
tPush and hold [SCAN](2) for 1 sec. to enter scan type se-
lection condition. Emits beep and blinks “S” indicator when a signal is re-
yRotate [DIAL] to select the desired scan type from “ALL,” ceived on a memory or call channel.
“BAND” and “PROG-xx (xx= 0–24),” “DUP.”
u Release [SCAN](2) to start the VFO scan watch.
• The transceiver checks the memory/bank channel(s) or call
channel every 5 sec.
• The watch resumes according to the selected scan resume con-
dition. (p. 81)

†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
84
MENU SCREEN OPERATION 11
■ General 1
MENU screen is used for programming infrequently changed rRotate [DIAL]† to select the desired value or condition, 2
values or conditions of functions. then push [ï](5) to return to the setting item selection
mode.
3
D Entering MENU screen and operation AUTO POWER OFF 4
OFF
e.g.) Set “AUTO power OFF” to 30 minutes. r 30MIN 5
q Push [MENU/LOCK] to enter MENU screen. 60MIN
90MIN 6
• MENU groups ***** MENU ***** 120MIN
appear. r SET MODE
SCAN
7
tPush [MENU/LOCK] to return to frequency indication, re-
DUP/TONE...
DISPLAY peat steps w to r to set another items. 8
SOUNDS [DIAL] 9
wRotate [DIAL]† to select the desired menu group, then 10
push [ï](5)†.
• Setting items SET MODE
11
r AP OFF
appear.
POWER SAVE
12
ATTENUATOR
MONITOR
13
DIAL SPEED
14
eRotate [DIAL]† to select the desired item, then push 15
[ï](5)†.
AUTO POWER OFF
16
rOFF
30MIN
17
60MIN
90MIN
18
120MIN
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
85
11 MENU SCREEN OPERATION

■ MENU screen indication for ■ Items list


B band* D Set mode
While B band is selected, MENU screen shows following in- ITEMS REF. ITEMS REF.
dication. AUTO POWER OFF p. 88 AUTO POWER ON p. 89
***** MENU ***** p. 88 p. 90
POWER SAVE LOCK
RX CALL S
MESSAGE/POS ATTENUATOR p. 88 PTT LOCK p. 90
DV VOICE M MONITOR p. 89 BUSY LOCKOUT p. 90
rSET MODE
DV SET MODE DIAL SPEED-UP p. 89 TIME-OUT TIMER p. 90
MIC SIMPLE MODE p. 89 ACTIVE BAND p. 91
MENU screen indication for B band.

*The optional UT-121 is required.

■ Menu list
MENU REF. MENU REF.
† —
CALL SIGN DV SET MODE pgs. 92–95

RX CALL SIGN† — SCAN pgs. 96, 97

MESSAGE/POSITION† — DUP/TONE… pgs. 97–99

DV VOICE MEMO† — DISPLAY pgs. 99–101

SET MODE pgs. 88–91 SOUNDS p. 102

†Refer to the chapter 7 for details.

86
MENU SCREEN OPERATION 11

D DV set mode D DUP/TONE set mode 1


Available for B band when the UT-121 is installed. Not available for the TV band selection.
ITEMS REF. ITEMS REF.
2
ITEMS REF. ITEMS REF.
AUTO REPLY p. 92 GPS MODE p. 94 OFFSET FREQ p. 97 DTCS CODE p. 98 3
DIGITAL CODE p. 92 ➥ GPS SENTENCE p. 94 REPEATER TONE p. 97 DTCS POLARITY p. 99
4
CTCSS TONE p. 98 DTMF SPEED p. 99
DV DATA TX p. 92 ➥ RMC SENTENCE p. 94
5
DIGITAL MONITOR p. 93 GGA SENTENCE p. 94
DIGITAL RPT SET p. 93 GLL SENTENCE p. 94 D DISPLAY set mode 6
RXCALL WRITE p. 93 GSA SENTENCE p. 94 ITEMS REF. ITEMS REF. 7
RXRPT WRITE p. 93 VTG SENTENCE p. 94 BACKLIGHT p. 99 SCAN NAME p. 101
8
GPS AUTO TX p. 95 BUSY LED p. 99 OPENING LOGO p. 101
DV AUTO DETECT p. 95 LCD CONTRAST p. 100 OPENING CALL S*2 p. 101 9
EDIT RECORD p. 95 RX CALL SIGN*1 p. 100 FONT SIZE p. 101 10
TX CALL SIGN*1 p. 100
p. 100
11
D Scan set mode RX MESSAGE*1

*1Available for B band when the UT-121 is installed.


12
ITEMS REF. ITEMS REF.
PRIO WATCH‡ p. 96 BANK LINK p. 97
*2Available when the UT-121 is installed. 13
PAUSE TIMER p. 96 ➥ BANK-A p. 97 D SOUNDS set mode 14
RESUME TIMER p. 96
ITEMS REF. ITEMS REF. 15
‡Not available during the TV band selection. p. 102 p. 102
BEEP LEVEL SCOPE AF OUTPUT 16
KEY-TOUCH BEEP p. 102 VOLUME SELECT p. 102
SCAN STOP BEEP p. 102 STANDBY BEEP*1 p. 102
17
*1Available for B band when the UT-121 is installed.
18
19
87
11 MENU SCREEN OPERATION

■ Set mode items


D Auto power OFF D Power save
The transceiver can be set to automatically turn OFF after a The power save function reduces the current drain to con-
specified time period with a beep when no key operations are serve battery power. This power save function can be turned
performed. OFF, if desired, by turning power ON and OFF.
In the default setting (“AUTO” selection), the power save func-
30 min., 60 min, 90 min, 120 min and OFF (default) can be tion is activated in a 1:1 (150 msec.: 150 msec.) ratio when no
specified. The specified time period is retained even when the signal is received for 5 sec. The ratio becomes 1:4 (150 msec.:
transceiver is turned OFF by the auto power OFF function. To 600 msec.) when no signal is received for another 60 sec.
cancel the function, select “OFF” in this item. Then the ratio becomes 1:8 (150 msec.: 1200 msec.) when no
AUTO POWER OFF AUTO POWER OFF signal is received for another more 60 sec.
r OFF OFF
r
POWER SAVE POWER SAVE
30MIN 30MIN
OFF r OFF
60MIN 60MIN
rAUTO AUTO
90MIN 90MIN
120MIN 120MIN

D Attenuator
The attenuator prevents distortion of a desired signal by very
strong RF signals near the desired frequency or when very
strong electric fields, such as from a broadcasting station, are
present at your location.

Select the attenuator function ON and OFF (default).


ATTENUATOR ATTENUATOR
r OFF OFF
ON r ON

88
MENU SCREEN OPERATION 11

D Monitor key action D Microphone simple mode 1


The monitor key, [SQL] , can be set as a ‘sticky’ key. When Microphone simple mode is used to change the function as-
set to the sticky condition, each push of [SQL] toggles the signments for keys on the optional HM-75A REMOTE CONTROL
2
monitor function ON and OFF. SPEAKER-MICROPHONE. (pgs. 121, 123) 3
• PUSH: Pushing and holding [SQL] to monitor the fre- • SIMPLE
quency. (default) • NORM-1 (default) 4
• HOLD : Push [SQL] momentarily to monitor the frequency • NORM-2 5
and push momentarily again to cancel it. MIC SIMPLE MODE MIC SIMPLE MODE

MONITOR MONITOR
SIMPLE r SIMPLE 6
rNORM-1 NORM-1
r PUSH PUSH
HOLD rHOLD NORM-2 NORM-2 7
8
9
D Dial speed acceleration D Auto power ON
Auto power ON function turns the transceiver power ON au- 10
The dial speed acceleration automatically speeds up the tun-
ing dial speed when rotating [DIAL] rapidly. tomatically after passing the set time period from power OFF. 11
• OFF : The dial speed acceleration is turned OFF. Select the desired time period within 30 minutes to 24 hours
• ON : The dial speed acceleration is tuned ON. in 30 minutes steps and OFF. (default: OFF) 12
(default) AUTO POWER ON
OFF
AUTO POWER ON
24:00
13
DIAL SPEED-UP DIAL SPEED-UP
OFF r OFF 14
rON ON
15
16
17
18
19
89
11 MENU SCREEN OPERATION

D Key lock Type D Busy lockout


While the key lock function is ON, [PWR], [PTT], [SQL], Turns the busy lockout function ON and OFF.
[VOL] and [MENU](Lock function only) can still be accessed. This function inhibits transmission while receiving a signal or
Accessible keys can be set to 1 of 4 groups. when the squelch is open. (default: OFF)
• NORMAL : [PWR], [PTT], [SQL], [VOL] and [MENU] BUSY LOCKOUT BUSY LOCKOUT
r OFF OFF
(Lock function only) accessible. (default)
ON r ON
• NO SQL : [PWR], [PTT], [SQL], and [MENU] (Lock func-
tion only) are accessible.
• NO VOL : [PWR], [PTT], [VOL], and [MENU] (Lock func-
tion only) are accessible. D Time-out timer
• ALL : [PWR], [PTT] and [MENU] (Lock function only) To prevent accidental prolonged transmission, etc., the trans-
are accessible. ceiver has a time-out timer. This function cuts a transmission
LOCK LOCK OFF after 1, 3, 5 or 10 min. of continuous transmission. This
r NORMAL NORMAL
NO SQL r NO SQL
timer can be cancelled.
NO VOL NO VOL • OFF : The time-out timer is turned OFF. (default)
ALL ALL • 1 to 10 MIN : The transmission is cut OFF after the set
period elapses.
TIME-OUT TIMER TIME-OUT TIMER
r OFF OFF
D PTT lock 1MIN 1MIN
3MIN 3MIN
Turns the PTT lock function ON and OFF. 5MIN 5MIN
Transmission with [PTT] is inhibited when ON is selected to 10MIN r10MIN

prevent accidental transmission, etc. (default: OFF)


PTT LOCK PTT LOCK
r OFF OFF
ON r ON

90
MENU SCREEN OPERATION 11

D Active band 1
Allows continuous frequency selection of the operating fre-
quency across all bands.
2
• SINGLE : A single operating frequency can be se- 3
lected within the current band. Push
[BAND] for band selection in this case. 4
• ALL : The operating frequency can be selected 5
continuously. (default)
ACTIVE BAND ACTIVE BAND
6
SINGLE r SINGLE
rALL ALL
7
8
9
10
11
12
13
14
15
16
17
18
19
91
11 MENU SCREEN OPERATION

■ DV set mode items


The following items are selectable when the optional UT-121 D Digital code
is installed. Sets the desired digital code for digital code squelch opera-
tion. Total of 100 codes (00–99) are available. (default: 00)
D Auto reply
DIGITAL CODE DIGITAL CODE
This function replies to an individual station call even you are 00 99
away from the transceiver.
After a manual transmission (pushing [PTT]), the Auto Reply
setting returns to OFF automatically.
• OFF : No reply is performed even a call is received.
D DV data TX
(default)
• ON : Sets caller’s call sign and reply to the call with During low-speed data operation, auto data transmission
the set own call sign automatically. function is available. This function transmits when data has
• VOICE : Sets caller’s call sign and reply to the call with been input from PC via the [DATA] jack. (default: PTT)
the recorded audio in REPLY VOICE memory of DV DATA TX DV DATA TX
r PTT PTT
DV VOICE MEMO. AUTO r AUTO
AUTO REPLY AUTO REPLY
r OFF OFF
ON ON
VOICE r VOICE

NOTE: When “ON” or “VOICE” is set to the auto reply


function, the power save function (p. 88) is turned OFF au-
tomatically to receive call sign signal properly.

92
MENU SCREEN OPERATION 11

D Digital monitor D RX call sign auto write 1


Sets the desired monitoring mode during digital mode opera- When an individual station call is received, the calling station
tion from “Auto,” “Digital” and “Analog.” call sign can be automatically set in “UR.” (default: OFF)
2
• AUTO : The transceiver sets monitoring mode to FM RXCALL WRITE RXCALL WRITE 3
r OFF OFF
and DV according to the received signal. (de-
fault)
AUTO r AUTO 4
• DIGITAL : Monitors in DV mode. 5
• ANALOG : Monitors in FM mode.
DIGITAL MONITOR DIGITAL MONITOR D Repeater call sign auto write 6
r AUTO AUTO
DIGITAL rDIGITAL When accessing a repeater with a call sign different than is 7
ANALOG ANALOG programmed, the repeater call sign can be set into “RPT1”
8
and/or “RPT2” automatically by reading the repeater’s trans-
mission. (default: OFF) 9
D Digital repeater setting RXRPT WRITE
r OFF
RXRPT WRITE
OFF
10
When accessing a digital repeater with a call sign different AUTO r AUTO
11
than is programmed, the repeater call sign can be stored into
“RPT1” and/or “RPT2” automatically by reading the repeater’s The transceiver sets the received repeater call sign for op- 12
transmission. The stored repeater’s call sign can be re-called eration. Therefore, when a different call sign is set for op-
when selecting the repeater call sign. (default: ON)
13
eration, the previously set repeater call sign will be lost.
DIGITAL RPT SET DIGITAL RPT SET 14
OFF r OFF
rON ON 15
16
17
18
19
93
11 MENU SCREEN OPERATION

D GPS mode
Sets GPS mode operation ON and OFF. • Sentence formatter setting
When the position information is received from a connected q Select “ON” in GPS mode item, then push [ï](5)† to enter
GPS receiver and the GPS Auto TX Timer setting (p. 95) is the sentence formatter selection.
set to a specific time, the transceiver automatically transmits w Rotate [DIAL]† to select the desired sentence formatter.
with the current position and message at every setting inter- • RMC, GGA, GLL, GSA and VTG are selectable.
val. (default: OFF) GPS SENTENCE GPS SENTENCE
r RMC:OFF RMC:OFF
GPS MODE GPS MODE GGA:ON r GGA:ON
r OFF OFF GLL:OFF GLL:OFF
ON r ON GSA:OFF GSA:OFF
VTG:OFF VTG:OFF

:SENTENCE :SENTENCE
e Push [ï](5)† to enter the desired sentence formatter se-
lection.
r Rotate [DIAL]† to select the setting.
RMC SENTENCE RMC SENTENCE
r OFF OFF
ON r ON

t Rotate [DIAL]† to select next sentence and repeat steps


w to r, or push [MENU/LOCK] to return to frequency in-
dication.
• Only three sentence formatters can be activated at same time.

†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
94
MENU SCREEN OPERATION 11

D GPS auto TX timer D Call sign edit record 1


Selects the desired interval for automatic position transmis- Selects the call sign programming when the call sign is edited
sion function from 5, 10, 30 second, 1, 3, 5, 10, 30 minutes or corrected with the pre-programmed call sign.
2
and OFF. (default: OFF) • OFF : The edited or corrected call sign is over writ- 3
• The position data is transmitted manually (with [PTT]) when “OFF” is ten.
selected. • SELECT : The edited or corrected call sign is pro- 4
GPS AUTO TX GPS AUTO TX grammed into the selected call sign memory. 5
r OFF OFF • AUTO : The edited or corrected call sign is pro-
5SEC 5SEC
grammed into a blank channel automatically. 6
10SEC 10SEC
30SEC r30SEC (default) 7
1MIN 1MIN EDIT RECORD EDIT RECORD
OFF OFF 8
SELECT r SELECT
rAUTO AUTO 9
D DV auto detect
When a signal other than DV mode is received during DV 10
mode operation, the transceiver has capability of automatic 11
FM mode selection.
• OFF : Operating mode is fixed in DV. (default) 12
• ON : The transceiver automatically selects FM 13
mode for temporary operation.
DV AUTO DETECT DV AUTO DETECT
14
r OFF OFF
ON r ON 15
16
17
18
19
95
11 MENU SCREEN OPERATION

■ Scan set mode items


D Priority watch D Scan resume timer
Activates priority watch or priority watch with alert (Bell). Selects the scan resume time from a paused frequency after
• OFF : The priority watch is turned OFF. (default) the received signal disappears.
• ON : The transceiver checks the memory channel fre- •0 : Scan resumes when a received signal disap-
quency every 5 sec. pears.
• BELL : The transceiver checks the memory channel fre- • 1–5 SEC : Scan pauses 1–5 sec. after a received signal
quency every 5 sec. You can be alerted with disappears. (default: 2 sec.)
beeps and blinking “S.” • HOLD : Scan pauses on the received signal even if it
PRIO WATCH PRIO WATCH disappears. Rotate [DIAL]† to resume manu-
r OFF OFF ally.
ON ON
rBELL
RESUME TIMER RESUME TIMER
BELL
1SEC 2SEC
r2SEC 3SEC
3SEC 4SEC
4SEC 5SEC
D Scan pause timer 5SEC rHOLD

Selects the scan pause time. When receiving signals, the


Scan resume timer must be set shorter than scan pause
scan pauses according to the scan pause time.
timer (previous item), otherwise this timer does not activate.
• 2–20 SEC : Scan pauses for 2–20 sec. on a received
signal in 2 sec. steps. (default: 10 sec.)
• HOLD : Scan pauses on a received signal until it dis-
appears. Rotate [DIAL] to resume manually.
PAUSE TIMER PAUSE TIMER
4SEC 14SEC
6SEC 16SEC
8SEC 18SEC
r10SEC 20SEC
12SEC rHOLD

96
MENU SCREEN OPERATION 11

■ DUP/TONE set mode items 1


D Memory bank link function D Offset frequency 2
Sets the memory bank link function ON (default) and OFF. The Sets the offset frequency for duplex (repeater) operation within 3
link function provides continuous bank scan, scanning all con- 0 to 159.995 MHz range.
tents in the selected banks during bank scan. OFFSET FREQ OFFSET FREQ
4
0.000.00 159.995.00
5
• Bank link setting
q Rotate [DIAL]† to select the bank that you want to change.
6
The default value may differ according to the selected fre-
BANK LINK BANK LINK
quency band (before accessing DUP/TONE set mode) and trans-
7
r BANK-A:ON \BANK-V:ON
BANK-B:ON BANK-W:ON ceiver version. 8
BANK-C:ON BANK-X:ON
BANK-D:ON BANK-Y:ON The selected tuning step in VFO mode is used for setting 9
BANK-E:ON rBANK-Z:ON
the offset frequency.
10
w Push [ï](5)† to enter bank setting.
e Rotate [DIAL]† to select the setting. D Repeater tone frequency 11
BANK-A BANK-A
r
Selects subaudible tone frequency for accessing a repeater, 12
OFF OFF
etc. Total of 50 tone frequencies (67.0–254.1 Hz) are available.
rON ON
(default: 88.5)
13
r Push [ï](5)† to set and return to the BANK LINK screen.
REPEATER TONE REPEATER TONE 14
88.5 254.1
t Rotate [DIAL]† to select next bank and repeat steps w to 15
r, or push [MENU/LOCK] to exit scan set mode.
16
17
18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
97
11 MENU SCREEN OPERATION

D TSQL frequency D DTCS code


Selects tone frequency for tone squelch or pocket beep oper- Selects DTCS (both encoder/decoder) code for DTCS squelch
ation from one of 50 available frequencies (67.0–254.1 Hz). operation. Total of 104 codes (023–754) are available.
(default: 88.5) (default: 023)
DTCS CODE DTCS CODE
CTCSS TONE CTCSS TONE
88.5 254.1 023 754

• Available subaudible tone frequencies • Available DTCS codes


67.0 79.7 94.8 110.9 131.8 156.7 171.3 186.2 203.5 229.1 023 054 125 165 245 274 356 445 506 627 732
69.3 82.5 97.4 114.8 136.5 159.8 173.8 189.9 206.5 233.6 025 065 131 172 246 306 364 446 516 631 734
71.9 85.4 100.0 118.8 141.3 162.2 177.3 192.8 210.7 241.8 026 071 132 174 251 311 365 452 523 632 743
74.4 88.5 103.5 123.0 146.2 165.5 179.9 196.6 218.1 250.3 031 072 134 205 252 315 371 454 526 654 754
77.0 91.5 107.2 127.3 151.4 167.9 183.5 199.5 225.7 254.1 032 073 143 212 255 325 411 455 532 662
036 074 145 223 261 331 412 462 546 664
The transceiver has 50 tone frequencies and consequently 043 114 152 225 263 332 413 464 565 703
047 115 155 226 265 343 423 465 606 712
their spacing is narrow compared with units having 38 051 116 156 243 266 346 431 466 612 723
tones. Therefore, some tone frequencies may receive in- 053 122 162 244 271 351 432 503 624 731
terference from adjacent tone frequencies.

98
MENU SCREEN OPERATION 11

D DTCS polarity ■ Display set mode items 1


Sets DTCS polarity from “BOTH N” (TX/RX: normal), “TN-RR”
(TX: normal, RX: reverse), “TR-RN” (TX: reverse, RX: normal) and
D Display backlighting 2
“BOTH R” (TX/RX: reverse). (default: BOTH N) The transceiver has display backlighting with a 5 sec. timer 3
DTCS POLARITY DTCS POLARITY
for night time operation. The display backlighting can be
r BOTH N BOTH N turned ON continuously or turned OFF, if desired. 4
TN-RR TN-RR • OFF : The backlight is turned OFF.
TR-RN TR-RN 5
BOTH R rBOTH R • ON : The backlight continuously lights ON.
• AUTO : Lights when an operation is performed, goes out 6
TX/RX: Normal polarity TX/RX: Reverse polarity
after 5 sec. (default) 7
*Continuously lights ON while operating with an
external DC power source. 8
D DTMF speed BACKLIGHT BACKLIGHT
9
OFF r OFF
Select the desired DTMF transmission speed from 100 msec, ON ON
200 msec, 300 msec, 500 msec. rAUTO AUTO
10
• 100 : 100 msec. interval; 5.0 characters per second 11
(default)
• 200 : 200 msec. interval; 2.5 characters per second D Busy LED
12
• 300 : 300 msec. interval; 1.6 characters per second The TX/RX indicator lights green while receiving a signal or 13
• 500 : 500 msec. interval; 1.0 character per second when the squelch is open. This indication can be turned OFF
DTMF SPEED DTMF SPEED
14
r
to conserve the battery power, if desired.
100 100
200 200 • OFF : The indicator does not function even if a signal is 15
300 300 received. 16
500 r500
• ON : The indicator lights green while receiving a signal
or when the squelch is open. (default) 17
BUSY LED
OFF
BUSY LED
r OFF
18
r ON ON
19
99
11 MENU SCREEN OPERATION

D LCD contrast D TX Call Sign Display


The contrast of the LCD can be selected from 16 levels. ☞ Available when the UT-121 is installed.
• 1 (Low contrast) to 16 (High contrast) (default: 8) Selects call sign display function from YOUR, MY and OFF.
LCD CONTRAST LCD CONTRAST
When this setting is set to YOUR or MY, the transceiver auto-
matically indicates the set station or your own call sign at dig-
ital mode transmission. (default: YOUR)
TX CALL SIGN TX CALL SIGN
Default (8) High contrast (16) OFF OFF
rYOUR YOUR
MY rMY

D RX Call Sign Display


☞ Available when the UT-121 is installed.
When a call is received, the calling station call sign can be in- D RX message Display
dicated automatically. (default: AUTO) ☞ Available when the UT-121 is installed.
RX CALL SIGN RX CALL SIGN Sets auto received message display function AUTO and OFF.
OFF r OFF When this setting is set to AUTO, the transceiver automati-
rAUTO AUTO
cally indicates and scrolls the received message.
(default: AUTO)
RX MESSAGE RX MESSAGE
OFF r OFF
r AUTO AUTO

100
MENU SCREEN OPERATION 11

D Scan name D Opening call sign 1


The programmed scan or bank name is displayed during the ☞ Available when the UT-121 is installed.
scan type selection. The set your own call sign, programmed in my call sign, can 2
• ON : The programmed scan or bank name is dis- be displayed at power ON. (default: OFF) 3
played. (default) OPENING CALL S OPENING CALL S

• OFF : The programmed scan or bank name is not dis- r OFF OFF 4
ON r ON
played. 5
SCAN NAME SCAN NAME
OFF r OFF 6
rON ON D Font size
Displayed character size during MENU mode indication in the
7
function display is selectable from Large and Small. 8
D Opening logo • LARGE : Makes 5 lines (Max. 5 items are displayed at the
The opening logo indication (Icom logo and transceiver name) same time). (default)
9
that is displayed at power ON can be skipped, if desired. • SMALL : Makes 6 lines (Max. 6 items are displayed at the 10
• ON : Opening logo is displayed at power ON. (default) same time).
• OFF : Opening logo indication is skipped. FONT SIZE FONT SIZE
11
OPENING LOGO OPENING LOGO
SMALL
rLARGE
r
SMALL
LARGE
12
OFF r OFF
rON ON 13
14
15
16
17
18
19
101
11 MENU SCREEN OPERATION

■ Sounds set mode items D Scope audio output


Select the audio output function capability during sweep with
D Beep output level band scope function.
Adjusts the key-touch beep tone level to the desired level • ON : The received audio sounds during sweep. (default)
within 39 levels. • OFF : No audio sounds during sweep.
BEEP LEVEL BEEP LEVEL SCOPE AF OUTPUT SCOPE AF OUTPUT
OFF r OFF
rON ON

Minimum level (no audio) Maximum level


D Volume select
Select the volume level adjustment from Both and Separate
The key-touch beep (following item) must be set to ON to for dualwatch operation.
have a beep tone. • BOTH : Both A band and B band volume level is ad-
justed with [VOL] at the same time. (default)
D Key-touch beep • SEPARATE : The Volume setting is adjusted indepen-
Turns the key-touch beep ON or OFF. (default: ON) dently in A and B bands with [VOL].
KEY-TOUCH BEEP KEY-TOUCH BEEP
VOLUME SELECT VOLUME SELECT
OFF r OFF r BOTH BOTH
r ON ON
SEPARATE r SEPARATE

D Scan stop beep D Standby Beep


Turns the scan stop beep function ON or OFF. (default: OFF) ☞ Available when the UT-121 is installed.
SCAN STOP BEEP SCAN STOP BEEP Turns the beep emission capability ON and OFF when the com-
r OFF OFF
ON rON
municating station finishes transmitting or the receive signal dis-
appears while in the digital mode operation. (default: ON)
STANDBY BEEP STANDBY BEEP
OFF r OFF
rON ON

102
OTHER FUNCTIONS DTMF MEMORY
r Ch01 12
■ Programming a DTMF code 1
DTMF codes are used for autopatching, accessing repeaters, r Push the desired keys to input the characters. 2
controlling other equipment, etc. The transceiver has 10 • [0]–[9] input “0”–“9,” [A](VFO) inputs “A,” [B](MR) inputs “B,”
DTMF memory channels (Ch01–Ch10) for storage of often- [C](CALL) inputs “C,” [D](BAND) inputs “D,” [#](.) inputs “#” and
DTMF MEMORY 3
[✱](REC) inputs “✱.” rCh01
used DTMF codes of up to 16 digits. 6
• Up to 16 digits can be programmed.
4
q Push and hold [DTMF.M](.) for 1 sec. to enter DTMF mem- • Push [MAIN/DUAL] to delete the cursor placed code. 5
ory. • Push and hold [MAIN/DUAL] for 1 sec. to delete the character at
the cursor and all following characters. 6
w Rotate [DIAL]† to select the desired DTMF memory chan-
t Repeat step r until the desired code is input. 7
nel.
• “T-CALL” appears when a 1750 Hz tone burst signal is selected.
(p. 33)
DTMF MEMORY
r Ch01
DTMF MEMORY
rCh01 8
01234567 012345 67
DTMF MEMORY 89AB 6
The cursor can 89AB 9
DTMF memory r DTMF MEMORY
Ch01 be moved when
channel
rCh01 SQL:SET MAIN:CLR

rotating [DIAL].
SQL:SET MAIN:CLR
10
Displays NO indication when 11
the blank channel is selected. DTMF MEMORY
r Ch01 12
01234567
e Push [≈
≈](6) to enter programming mode. 89ABC*#0 13
• Previously programmed DTMF code is displayed if programmed. :SET :SEL

DTMF MEMORY
DTMF MEMORY
:BACK :EDIT
14
r Ch01 The display after 16th digit of
6 rCh01
The cursor is blinking when 6
channel 01 is input. 15
entering programming mode.
y Push [MENU/LOCK] to program the DTMF code and exit 16
programming mode. 17
• Entering 16th digit automatically exits the programming mode.
u Push [VFO] to exit DTMF memory. 18
DTMF MEMORY DTMF MEMORY
Ch01 DTMF MEMORY
Ch01
01234567
Ch01 DTMF MEMORY
Ch01
012345 67
19
6
89AB 6
01234567 89AB 012345 7
89AB 6 89AB
103
SQL:SET MAIN:CLR SQL:SET MAIN:CLR
SQL:SET MAIN:CLR SQL:SET MAIN:CLR
12 OTHER FUNCTIONS
+DUP DTCS
FM PRIO WX EMR

■ Transmitting a DTMF code A 438 500 25


MemoName PSKIP
µ 000
D Transmitting from DTMF memory D Transmitting a DTMF code directly
5D28AB4

The selected DTMF code is transmitted at each push of the DTMF code can be transmitted via keypad directly while
[SQL] switch while transmitting. transmitting.

The transmitting speed at which DTMF memories send in- q Set the desired frequency. (p. 18)
dividual DTMF characters can be set in “DTMF SPEED” w While pushing [PTT], push the desired keys to transmit the
menu. (p. 99) DTMF code.
• [0]–[9] input “0”–“9,” [A](VFO) inputs “A,” [B](MR) inputs “B,”
q Set the desired frequency. (p. 18) [C](CALL) inputs “C,” [D](BAND) inputs “D,” [#](.) inputs “#” and
w Push and hold [DTMF.M](.) for 1 sec. to enter DTMF mem- [✱](REC) inputs “✱.”
ory.
e Rotate [DIAL]† to select the desired DTMF memory chan- FM

nel. A
438 500
r Push [ï](5) to set the DTMF memory. P SKIP

t Push [VFO] to exit DTMF memory.


y While pushing [PTT], push [SQL] to transmit the selected

     
DTMF code.    

 +DUP DTCS   


FM PRIO WX EMR

A 438 500 25

 
MemoName PSKIP
µ 000
5D28AB4

 
   

    

104
SQL:BACK MAIN:CLR

OTHER FUNCTIONS
DTMF MEMORY
12
Ch01

■ Clearing a DTMF memory ■ Confirming a DTMF memory SQL:BACK MAIN:CLR


1
An unwanted DTMF memory can be cleared (erased). A DTMF memory can be confirmed with a DTMF tone. 2
q Push and hold [DTMF.M](.) for 1 sec. to enter DTMF mem- q Push and hold [DTMF.M](.) for 1 sec. to enter DTMF mem- 3
ory mode. ory mode. 4
w Rotate [DIAL]† to select the desired DTMF memory chan- w Rotate [DIAL]† to select the desired DTMF memory chan-
nel to be cleared. nel. 5
e Push and hold [CLR](1) for 1 sec. to clear the selected e Push [SQL] to confirm the DTMF memory contents.
6
DTMF memory channel.
[DIAL] • When entering DTMF programming [DIAL] Push [SQL], then sounds DTMF 7
mode. codes.
DTMF MEMORY DTMF MEMORY
8
r Ch01 r Ch01
01234567 01234567 9
89AB 89ABC*#0

SQL:BACK MAIN:CLR
:SET
:BACK
:SEL
:EDIT
10
11
• After clearing the DTMF memory.
DTMF MEMORY
12
r Ch01
13
SQL:BACK MAIN:CLR
14
15
16
17
18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8)
105
12 OTHER FUNCTIONS

■ Setting DTMF transfer speed ■ Tone frequency and DTCS


The DTMF transfer speed can be selected. code
q Enter “DTMF SPEED” in DUP/TONE… set mode. (p. 99) D Subaudible (repeater) tone
MENU screen ➪ DUP/TONE... ➪ DTMF SPEED Some repeaters require subaudible tones to be accessed.
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) Subaudible tones are superimposed over your normal signal
w Rotate [DIAL]† to select DTMF transfer speed as below. and must be set in advance.
100: Transfer the*****
DTMF data
MENU per*****
about 100 msec.
DV SET MODE
200: Transfer the DTMF
SCAN
data per about 200 msec. D Tone and DTCS squelches
300: Transfer the
rDTMF data per about 300 msec.
DUP/TONE...
The tone squelch (CTCSS) or DTCS squelch opens only
500: Transfer the DTMF data per about 500 msec.
when receiving a signal containing a matching subaudible
DTMF SPEED tone or DTCS code, respectively. You can silently wait for
r 100
200
calls from group members using the same tone or code. Sep-
300 arate tone frequencies can be set for repeater and tone
500 squelch/pocket beep operation.

e Push [ï](5) (or [Ω


Ω](4)) to return to DUP/TONE… set mode, D Pocket beep
and push [MENU/LOCK] to return to frequency indication. These functions use subaudible tones or DTCS codes for
calling and can be used as a “common pager” to inform you
that someone has called while you were away from the trans-
ceiver.

†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
106
***** MENU *****
OTHER FUNCTIONS
DV SET MODE
12
SCAN
rDUP/TONE...

D Setting subaudible tones for repeater or D Setting DTCS code for DTCS squelch or 1
CTCSS TONE REPEATER TONE
tone squelch beep 88.5 88.5
200 200
2
q Enter “CTCSS TONE (or RPT TONE)” in DUP/TONE… set q Enter “DTCS CODE”
r300in DUP/TONE... set mode.
r (p.
30098)
mode. (pgs. 97, 98) MENU screen ➪ DUP/TONE... ➪ DTCS TONE
500 500 3
MENU screen ➪ DUP/TONE... ➪ CTCSS TONE (Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) 4
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
w Rotate [DIAL]† to select the desired DTCS tone code. 5
w Rotate [DIAL]† to select the desired repeater or CTCSS • Each operating band and each memory channel have indepen-
tone frequency. dent settings. ***** MENU *****
6
• Each operating band and each memory channel have indepen- DV SET MODE
• See page 98 for available
SCAN
DTCS codes for details. 7
dent settings.
***** MENU ***** e Push [ï](5) (or [ΩΩ](4))
r to return to DUP/TONE… set mode,
DUP/TONE...
DV SET MODE
• See page 98 for available tone frequencies for details. and push [MENU/LOCK] to return to frequency indication. 8
SCAN
er
Push [ï](5) (or [Ω
DUP/TONE... Ω](4)) to return to DUP/TONE… set mode, 9
DTCS CODE
and push [MENU/LOCK] to return to frequency indication. 023
200 10
CTCSS TONE REPEATER TONE r 300
88.5
200
88.5
200
500 11
r300 r300

500 500
12
DTCS phase mode can be selected in “DTCS POLARITY”
menu. (p. 99) 13
14
***** MENU *****
15
DV SET MODE
SCAN 16
r DUP/TONE...
17
DTCS CODE
18
023
200 19
r300
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
500 107
12 OTHER FUNCTIONS
***** MENU *****
DV VOICE M

■ Digital code and digital call sign setting


SET MODE
rDV
The optional
SET MODE UT-121 is required

D Setting digital code for digital code squelch D Setting the YOUR and MY call signs for
DIGITAL CODE
or beep digital call sign
00squelch or beep
200
q Push [MAIN/DUAL] to select B band, then push and hold q Push [MAIN/DUAL]
r300
to select B band, then push and hold
[MODE](REC) for 1 sec. several times to select DV mode. [MODE](REC) for500
1 sec. several times to select DV mode.
w Enter “DIGITAL CODE” in DV SET MODE. (p. 92) w Enter “YOUR CALL SIGN” in CALL SIGN set mode. (p. 36)
MENU screen ➪ DV SET MODE ➪ DIGITAL CODE MENU screen ➪ CALL SIGN ➪ YOUR CALL SIGN
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) (Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
***** MENU ***** ***** MENU *****
r
CALL SIGN
e Rotate [DIAL]† toDV VOICE M
select
SET MODE
the desired digital code. e Rotate [DIAL]† toRX
select the desired call sign.
CALL S
• Each operatingrband
DVand each memory
SET MODEchannel have indepen- • Input the call signMESSAGE/POS
if the desired call sign is not stored in the
dent settings. transceiver. See p. 36 for detail.
DIGITAL CODE YOUR CALL SIGN
rU01
00
200 ABCDEF
r300 r300

500 500

r Push [ï](5) (or [Ω


Ω](4)) to return to DV SET MODE, and r Push [ï](5) (or [Ω
Ω](4)) to return to CALL SIGN set mode.
push [MENU/LOCK] to return to frequency indication. t Rotate [DIAL]† MY
to select
CALL “MY CALL SIGN” in CALL SIGN
SIGN
***** MENU *****
r CALL SIGN
rM01
set mode, then push [ï](5)† to enter “MY CALL SIGN” set-
GHIJKL
RX CALL S ting. r300
MESSAGE/POS
MENU screen ➪ 500CALL SIGN ➪ MY CALL SIGN
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
YOUR CALL SIGN
rU01
ABCDEF
r300

500

†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
108 MY CALL SIGN
r M01
500

***** MENU *****


OTHER FUNCTIONS 12
r CALL SIGN
RX CALL S
MESSAGE/POS
1
YOUR CALL SIGN
r U01
2
ABCDEF
r 300
3
y Rotate [DIAL]† to 500 the desired
select call sign. CAUTION!: Use digital code squelch when operating with
• Input the call sign if the desired call sign is not stored in the 4
more than 3 stations. Because the digital call sign squelch
transceiver. See pgs. 34 and 35 for detail. function recognizes “MY CALL SIGN,” the digital call sign 5
squelch function can be used when operating with only one
MY CALL SIGN
r M01
6
station.
GHIJKL
r 300 7
500 NOTE:
• The tone/DTCS code squelch opens sometimes when
8
u Push [ï](5) to set call sign and push [MENU/LOCK] to other stations communicate with adjacent tone frequency 9
return to frequency indication. or DTCS code.
10
11
12
13
14
15
16
17
18
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
19
109
12 OTHER FUNCTIONS

■ Tone/DTCS squelch ■ Digital code/digital call sign


q Set the desired operating frequency, CTCSS tone and squelch The optional UT-121 is required
DTCS code.
w Push and hold [TONE](7) for 1 sec. several times to acti- q Set the desired operating frequency on DV mode, Digital
vate the tone or DTCS squelch. (TONE, TSQL or DTCS) code and MY CALL SIGN.
• Subaudible tone encoder “TONE,” tone squelch “TSQL,” pocket w Push and hold [DSQ](7) for 1 sec. several times to acti-
beep “TSQLS,” DTCS squelch “DTCS,” DTCS beep vate the digital code or digital call sign squelch. (DSQL or
“DTCSS” and no tone operation are activated in order. CSQL)
• Rotating [DIAL] while pushing [TONE](7) also selects the tone • Digital call sign squelch “DSQL,” Digital call sign beep
+DUP TONE
functions. “DSQLS”,
FM PRIO WX EMR
Digital code
25 squelch
+DUP DTCS

“CSQL,” Digital code beep


FM PRIO WX EMR
B
145300 B
145300 25
e Operate the transceiver in the normal way. “CSQLS” and no tone operation
MemoName PSKIP are activated in order.
MemoName PSKIP

r When the received signal includes a matching tone/code, • Rotating [DIAL] while pushing [DSQ](7) also selects the tone
the squelch opens and the signal can be heard. functions.+DUP TSQL
FM PRIO WX EMR
+DUP DTCS
FM PRIO WX EMR

• When the received signal’s tone/code does not match, e Operate the
B
145300 25 B
145300
transceiver in the normal way.
25

MemoName PSKIP MemoName PSKIP


tone/DTCS squelch does not open, however, the S-indicator r When the received signal includes a matching call
shows signal strength. sign/code, the squelch opens and the signal can be heard.
+DUP TSQL
FM PRIO WX EMR
+DUP DTCS
FM PRIO WX EMR

• To open the squelch manually, push and hold [SQL]. B


145300
• When the received
25 B
145300
signal’s call sign/code 25
does not match, digital
Subaudible tone encoder No tone operation MemoName PSKIP MemoName PSKIP
call sign/digital code squelch does not open, however, the S-in-
+DUP TONE
FM PRIO WX EMR
+DUP DTCS
FM PRIO WX EMR
dicator shows signal strength.
B
145300 25 B
145300 25 • To open the squelch manually, push and hold [SQL].
MemoName PSKIP MemoName PSKIP
Pocket beep DTCS beep Digital call sign pocket beep Digital code pocket beep
+DUP TSQL +DUP DTCS +DUP DSQL
+DUP CSQL
FM PRIO WX EMR FM PRIO WX EMR DV PRIO WX EMR
DV PRIO WX EMR
B
145300 25 B
145300 25 B
145300 25 B
145300 25
MemoName PSKIP MemoName PSKIP MemoName PSKIP MemoName PSKIP
Tone squelch DTCS squelch Digital call sign squelch Digital code squelch
+DUP TSQL +DUP DTCS
FM PRIO WX EMR FM PRIO WX EMR +DUP DSQL

145300 25 145300
+DUP CSQL
B B 25 DV PRIO WX EMR
DV PRIO WX EMR

MemoName PSKIP MemoName PSKIP


B
145300 25 B
145300 25
MemoName PSKIP MemoName PSKIP

110 +DUP DSQL


DV PRIO WX EMR
+DUP CSQL
DV PRIO WX EMR
B
145300 25 B
145300 25
MemoName PSKIP
+DUP TSQL +DUP DTCS
FM PRIO WX EMR FM PRIO WX EMR
B
145300 25 B
145300 25
MemoName PSKIP MemoName PSKIP

OTHER FUNCTIONS 12

■ Pocket beep function


145300 B
+DUP DSQL
DV PRIO WX EMR

145300
25 B
+DUP CSQL
DV PRIO WX EMR
25
■ DTCS polarity setting 1
MemoName
q Set the desired PSKIP
MemoName
operating frequency. PSKIP
q Enter “DTCS P” in DUP/TONE... set mode. (p. 99) 2
w Set the desired CTCSS tone, DTCS code, Digital call sign MENU screen ➪ DUP/TONE... ➪ DTCS P
or Digital code.
+DUP DSQL
DV PRIO WX EMR
+DUP CSQL
DV PRIO WX EMR
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
3
B
145300 25 145300 25
B

e Push and MemoName


hold [TONE](7)/[DSQ](7)
PSKIP for 1 sec. several
MemoName PSKIP 4
times to activate the pocket beep, DTCS beep, Digital call DUP/TONE...

sign beep or Digital code beep. (“TSQLS,” “DTCS


rRPT TONE 5
CTCSS TONE
S,” “DSQLS” or “CSQLS”) rDTCS CODE 6
rDTCS P
• Rotating [DIAL] while pushing [TONE](7)/[DSQ](7) also selects
the tone functions. 7
Pocket beep DTCS beep w Rotate [DIAL]† to select the desired DTCS polarity mode. 8
+DUP TSQL +DUP DTCS • BOTH N: Normal phase is used for both TX and RX.
B
FM PRIO WX EMR

438 500 25 B
FM PRIO WX EMR

438 500 25 (Default) 9


MemoName PSKIP MemoName PSKIP
• TN-RR: Normal phase is used for TX; Reverse 10
Digital call sign pocket beep Digital code pocket beep phase for RX.
+DUP DSQL
DV PRIO WX EMR

438 500 25
+DUP CSQL
DV PRIO WX EMR
• TR-RN: Reverse phase is used for TX; Normal 11
438 500 25
B B

MemoName PSKIP phase for RX.


MemoName PSKIP
12
• BOTH R: Reverse phase is used for both TX and
r When a signal with the correct tone, code, digital call sign RX. 13
or digital code is received, the transceiver emits beep e Push [ï](5) (or [Ω
Ω](4)) to return to DUP/TONE… set mode,
and push [MENU/LOCK] to return to frequency indication.
14
tones for 30 sec. and blinks “S.”
t Push [PTT] to answer or push [SQL] to stop the beeps 15
and blinking. 16
17
18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
111
12 OTHER FUNCTIONS

■ Tone scan
The transceiver can detect the subaudible tone frequency and
[DIAL]
DTCS code in a received signal. By monitoring a signal that
is being transmitted on a repeater input frequency, you can
determine the tone frequency required to access the repeater.

q Set the desired frequency or memory channel to be


checked for a tone frequency or DTCS code.
w Push and hold [TONE](7) for 1 sec. several times to acti-
vate the repeater tone, tone squelch or DTCS squelch.
(TONE, TSQL or DTCS)
• Rotating [DIAL] while pushing and holding [TONE](7) also se-
lects the tone functions. Tone scan for tone Tone scan for DTCS squelch.
e Push and hold [T.SCAN](9) for 1 sec. to start the tone squelch/repeater tone.
+DUP DTCS +DUP DTCS
DV PRIO WX EMR
scan. A
FM PRIO WX EMR

1713 25 A
662 25

• To change the scanning direction, rotate [DIAL]. MemoName PSKIP MemoName PSKIP

r When the tone frequency or DTCS code is decoded, the


set mode contents are programmed with the frequency or The decimal point is blinking while
code. tone scanning.
• The tone scan pauses for the set period in scan pause timer
(p. 96) when a tone frequency or DTCS code is detected. t Push [VFO] to stop the scan.
• The decoded tone frequency is used for the repeater tone fre- • If the scan is cancelled before the transceiver detects the tone or
quency when the tone squelch is OFF. code, the set mode contents are not changed.
• The decoded tone frequency is used for the tone squelch fre- • The detected tone is temporary operation only. The stored tone
quency (CTCSS TONE) when the tone squelch is ON. setting in memory or call channel won’t be changed.
• The decoded DTCS code is used for the DTCS code when the
DTCS squelch is ON.

112
OTHER FUNCTIONS 12

■ Beep tones ■ Key lock effect 1


You can select to have confirmation beeps sound at the push D Lock function 2
of a switch. The output level can be adjusted within 39 levels
or to the related level of the volume with “BEEP LEVEL” in
The lock function prevents accidental frequency changes and 3
accidental function access.
sounds set mode. (p. 102) 4
MENU screen ➪ SOUNDS ➪ BEEP LEVEL ➥ Push [MENU/LOCK] for 1 sec. to toggle the lock function
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
5
ON and OFF.
You can select silent operation by turning beep tones OFF • [PWR], [VOL], [SQL] and [PTT] can still be accessed while the 6
lock function is ON. (default)
with “KEY-TOUCH BEEP” in sounds set mode. (p. 102) 7
MENU screen ➪ SOUNDS ➪ KEY-TOUCH BEEP Appears.
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
8
FM
A
439 540 9
P SKIP 10
■ Dial speed acceleration D Key lock type
11
The dial speed acceleration automatically speeds up the tun- 12
While the lock function is ON, [PWR], [VOL], [SQL] and
ing dial speed when rotating [DIAL] rapidly. 13
[PTT] can still be accessed. Accessible switches can be set
This function can be turned ON and OFF with “DIAL SPEED” to one of 4 groups with “LOCK” in set mode. (p. 90) 14
in set mode. (p. 89) MENU screen ➪ SET MODE ➪ LOCK
MENU screen ➪ SET MODE ➪ DIAL SPEED
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) 15
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) • “NORMAL” : [PWR], [VOL], [SQL] and [PTT] are accessible. 16
• “NO SQL” : [PWR], [SQL] and [PTT] are accessible. 17
• “NO VOL” : [PWR], [VOL] and [PTT] are accessible.
• “ALL” : [PWR] and [PTT] are accessible. 18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
113
12 OTHER FUNCTIONS

■ Power save ■ Auto power OFF


The power save function reduces the current drain to con- The transceiver can be set to automatically turn OFF after a
serve battery power. specified period with a beep when no switch is pushed.

The power save duty cycle, the ratio of receive circuit on to 120 min., 90 min., 60 min., 30 min. and OFF can be speci-
receive circuit off during standby, can be set to automatic (de- fied. The specified period is retained even when the trans-
fault), 1 : 1 (150 msec. : 150msec.), 1 : 4 (150 msec. : 600msec.), 1 ceiver is turned OFF by the auto power-off function. To cancel
: 8 (150 msec. : 1200msec.) or OFF with “POWER SAVE” in set the function, select “OFF” in the auto power-off item in set
mode. (p. 88) mode.
MENU screen ➪ SET MODE ➪ POWER SAVE This can be selected with “AP OFF” in set mode. (p. 88)
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) MENU screen ➪ SET MODE ➪ AP OFF
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)
• “AUTO” selects “1:1” duty ratio when receiving no signal for 5 sec.,
then “1:4” 60 sec. after that. The ratio becomes “1:8” when no signal
is received for another 60 sec.

No signal 150 msec. 600 msec. 1200 msec.


■ Auto power ON
5 sec.
Circuit ON The transceiver can be set to automatically turn ON after a
specified period. The timer can be selected within 30 min. to
Circuit OFF
24 hrs. in 30 min. steps.
150 msec.
60 sec. 60 sec. This can be selected with “AP ON” in set mode. (p. 89)
MENU screen ➪ SET MODE ➪ AP ON
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.)

When operating with battery pack or case and the battery


is exhausted, auto power-on does not function.
A slight current still flows in the circuits during standby con-
dition of the auto power-on function.
114
OTHER FUNCTIONS 12

■ Time-out timer ■ [MIC/SP] jacks 1


To prevent accidental prolonged transmission, etc., the trans- To connect external equipment such as speaker, microphone, 2
ceiver has a time-out timer. This timer cuts a transmission TNC, etc. refer to the diagram below.
OFF after 1, 3, 5 or 10 min. of continuous transmission. This
3
External
timer can be cancelled (default). the [SP] jack speaker 4
SP (AF OUT)
SP
Approx. 10 sec. before the time-out timer is activated, the INTERNAL SP
CLONE
3.5 (d) mm
plug
5
transceiver emits a beep tone as a warning. SP
SP GND
GND 6
Impedance 8 Ω
This can be selected with “TOT” in set mode. (p. 90) 7
MENU screen ➪ SET MODE ➪ TOT External
2.5 (d) mm
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) MIC
the [MIC] jack plug microphone 8
MIC
3.0 V
330 Ω 33 kΩ 9
MIC GND MIC
3.3 V (See below) PTT
GND
Impedance 2 kΩ
10
■ PTT lock 11
The center terminal of [MIC] outputs 3.3 V DC via 330 Ω
To prevent accidental transmission, etc., the transceiver has a
resistor.
12
PTT lock function.
13
This can be selected with “PTT LOCK” in set mode. (p. 90) 14
MENU screen ➪ SET MODE ➪ PTT LOCK
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) 15
16
17
18
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
115
12 OTHER FUNCTIONS

■ Cloning function
The IC-E91 has transceiver-to-transceiver data cloning capa- The optional RS-91 REMOTE CONTROL SOFTWARE is also
bility. This function is useful when you want to copy all of the available to clone/edit contents with a PC (for Microsoft® Win-
programmed contents from one IC-E91 to another. dows® 98/98SE/ME/2000XP) and using ICF format files.
• An optional OPC-474 CLONING CABLE is required.
Microsoft® and Windows® are registered trademarks of Microsoft Corporation in
q Turn the transceiver’s power OFF, then connect an op- the U.S.A. and other countries.
tional OPC-474 between both [SP] jacks.
w While pushing [MR] and [MENU/LOCK], push and hold
[PWR] for 1 sec. to enter cloning mode.
• “CLONE M” appears.
e Push [PTT] on the “master” transceiver.
• “CLONE OUT M” appears and the bar meter shows that cloning
is taking place.
• After the cloning is completed, the display returns to “CLONE M.”
r Push and hold [PWR] for 1 sec. to turn power OFF.
OPC-474

to the [SP] jack to the [SP] jack

116
OTHER FUNCTIONS 12

■ Resetting 1
The function display may occasionally D All reset D Partial reset 2
display erroneous information (e.g. q Push and hold [PWR] for 1 sec. to q Push and hold [PWR] for 1 sec. to
when first applying power). This may be
3
turn power OFF. turn power OFF.
caused externally by static electricity or w While pushing and holding [VFO], w While pushing and holding [VFO], then 4
by other factors. [MR] and [BAND], then turn power turn power ON to partially reset the 5
ON to reset the CPU. transceiver.
If this problem occurs, turn power OFF.
• “ALL RESET” appears when resetting 6
After waiting a few seconds, turn power the CPU (See the illustration below). [NOTE]: No message appears on the
ON again. If the problem persists, per- display after the partial reset is done. 7
form either or both procedures below.
8
• All reset ALL RESET
9
Reset the CPU before operating the
transceiver for the first time, or if the in- 10
ternal CPU malfunctions, to clear and +DUP DTCS 11
FM PRIO WX EMR
return all programmed contents to their
default settings.
A
B 145 000 25 12
• Partial reset 13
If you want to initialize the operating 14
CAUTION: Resetting the CPU re-
conditions (VFO frequency, VFO set-
turns all programmed contents to 15
tings, set mode contents) without clear-
their default settings.
ing the memory contents, a partial reset 16
function is available for the transceiver.
17
18
ALL RESET
19
+DUP DTCS
117
FM PRIO WX EMR
A
B 25
13 TROUBLESHOOTING
If your transceiver seems to be malfunctioning, please check the following points before sending it to a service center.
PROBLEM POSSIBLE CAUSE SOLUTION REF.
No power comes ON. • The batteries are exhausted. • Replace the batteries or charge the battery pack. pgs. 1, 10–12
• The battery polarity is reversed. • Check the battery polarity. p. 12
No sound comes from the • Volume level is too low. • Rotate [VOL] to suitable level. p. 20
speaker. • Different tone is selected with tone/DTCS • Check the tone using tone/DTCS scan. p. 112
squelch.
Transmitting is impossible. • The batteries are exhausted. • Replace the batteries or charge the battery pack. pgs. 1, 10–12
• A frequency outside of the 144/430 MHz • Reset the frequency within 144/430 MHz amateur p. 24
amateur bands is set. bands.
No contact possible with • Different tone is selected with tone/DTCS • Check the tone/DTCS using tone scan. p. 112
another station. squelch.
Frequency can not be set. • The lock function is activated. • Push [MENU/LOCK] for 1 sec. to cancel the function. p. 25
• Push [VFO] to set VFO mode.
• Memory mode or call channel is selected. p. 15
Program scan function • Memory mode or call channel is selected. • Push [VFO] to set VFO mode. p. 15
can not start. • Same frequencies are programmed both • Programming different frequencies in “✱A” and “✱B” p. 74
“✱A” and “✱B” of PROGRAM-CH. respectively.
Memory scan function can • VFO mode or call channel is selected. • Push [MR] to set memory mode. p. 15
not start. • The programmed memory channel is only • Program more than 2 memory channels. p. 66
one.
The displayed frequency is • The CPU malfunctioned. • Reset the transceiver. p. 117
erroneous. • External factors caused a fault. • Remove and re-attach the battery pack or battery p. 1
case.
Can not charge the battery • Turn the transceiver’s power ON. • Turn the transceiver’s power OFF, or insert only the pgs. 11 ,20
with BC-139 (LED blinks battery pack into the BC-139 to charge it.
orange).

118
SPECIFICATIONS 14
D General 1
• Frequency coverage* : (unit: MHz) • Antenna connector : SMA (50 Ω)
Version A band B band • Dimensions : 58.4(W)×103(H)×34.2(D) mm 2
Europe, Tx: 144–146, 430–440 Tx: 144–146, 430–440 (projections not included)
U.K. Rx: 0.495–999.990 Rx: 118–174, 350–470 • Weight (approx.) : 300 g (with antenna and BP-217) 3
• Data connector : 3-conductor 2.5 (d) mm
Tx: 144–146, 430–434,
435–438 Tx: 144–146, 430–434, 435–438
4
Italy Rx: 0.495–29.995, 50–51,
76–136.995, 144–146,
Rx: 118–136.995, 144–146,
430–434, 435–438
D Transmitter 5
430–434, 435–438 • Modulation system : 6
Tx: 144–146, 430–440 FM Variable reactance freq. modulation
France
Rx: 0.495–29.995, 50–52,
Tx: 144–146, 430–440
Rx: 118–136.995, 144–146,
DV (Digital)† GMSK reactance freq. modulation 7
76–136.995, 144–146, • Output power (at 7.4 V DC) : High 5.0 W, Low 0.5 W (approx.)
430–440
430–440
• Max. frequency deviation : ±5.0 kHz (FM wide: approx.) 8
±2.5 kHz (FM narrow: approx.)
*Specificatins guaranteed for 144–148 MHz and 430–440 MHz ranges only.
• Spurious emissions : Less than –60 dB
9
• Mode : FM, AM (Rx only), WFM (Rx only), DV†
• No. of memory channels : 1304 • Ext. mic. connector : 3-conductor 2.5 (d) mm; (1⁄10˝)/2 kΩ 10
(incl. 100 scan edges and 4 call channels)
• Usable temp. range : –20°C to +60°C
11
• Tuning steps : 5‡, 6.25‡, 8.33‡, 9‡, 10, 12.5, 15, 20, 25, 12
30, 50, 100, 125 and 200 kHz
• Frequency stability : ±2.5 ppm (–20°C to +60°C) 13
• Power supply : 10.0–16.0 V DC for external DC power,
or specified Icom’s battery pack
14
• Digital transmission speed : 4.8 kbps† 15
• Voice coding speed : 2.4 kbps†
• Current drain (at 7.4 V DC) : 16
Tx High 144 MHz 2.1 A typical
430 MHz 2.2 A typical 17
Tx Low 0.8 A (approx.)
Rx max. power 340 mA typical (dualwatch; FM/DV†)
18
standby 170 mA typical (dualwatch; FM/DV†) †Available when UT-121 is installed. 19
‡Selectable depending on the operating frequency band.
119
14 SPECIFICATIONS

D Receiver
• Receive system : • Selectivity :
FM/AM Double-conversion superheterodyne FM (Wide), AM More than 50 dB
WFM Triple-conversion superheterodyne FM (Narrow), DV† More than 45 dB
• Intermediate frequencies : WFM More than 300 kHz/–3 dB
1st A band 61.65 MHz/59.25 MHz (WFM) Less than 700 kHz/–20 dB
B band 46.35 MHz • Spurious and image rejection ratio:
2nd 450 kHz/13.35 MHz (WFM) VHF More than 60 dB
3rd 1.95 MHz (WFM only) UHF More than 50 dB
• Sensitivity (except spurious points): (Intermediate freq.; More than 60 dB)
AM (1 kHz/30% Mod.; 10 dB S/N) • Audio output power : More than 200 mW at 10% distortion
0.495–4.995 MHz 1.3 µV typ. (at 7.4 V DC) with an 8 Ω load
5.000–29.995 MHz 0.56 µV typ. • Ext. speaker connector : 3-conductor 3.5(d) mm; (1⁄8˝)/8 Ω
118.000–137.000 MHz 0.5 µV typ.
222.000–246.995 MHz 0.79 µV typ.
247.000–329.995 MHz 1 µV typ.
FM (1 kHz/3.5 kHz Dev.; 12 dB SINAD)
VHF (Amateur band only) 0.14 µV typ.
UHF (Amateur band only) 0.16 µV typ.
1.625–29.995 MHz 0.4 µV typ.
30.000–117.995 MHz 0.25 µV typ.
118.000–173.995 MHz 0.18 µV typ.
174.000–349.995 MHz 0.32 µV typ.
350.000–469.995 MHz 0.22 µV typ.
470.000–599.995 MHz 0.32 µV typ.
600.000–999.990 MHz 0.56 µV typ.
WFM (1 kHz/52.5 kHz Dev.; 12 dB SINAD)
76.000–108.000 MHz 1 µV typ.
175.000–221.995 MHz 1.8 µV typ.
470.000–770.000 MHz 2.5 µV typ.
DV (digital/PN9 4.8 kbps; BER 1%)†
Amateur bands 0.22 µV typ. †Available when UT-121 is installed.
120
OPTIONS 15
• UT-121 digital unit • CP-19R cigarette lighter cable with dc-dc converter 1
Provides DV mode operation for IC-E91. Allows you to operate the transceiver through a 12 V ciga-
rette lighter socket, and also charge the attached battery 2
• RS-91 remote control software
Allows you to operate the transceiver, as well as the easy
pack (during stand-by only) regularly. A built-in DC-DC con- 3
verter outputs 11 V DC.
memory management from the connected PC for Microsoft® • OPC-254L dc power cable 4
Windows® 98/98SE/ME/2000/XP with an RS-232C (COM)
port. In addition, low-speed data communication is enabled
For operation and charging via an external power supply.
5
with this software for DV mode operation. A data communi- • OPC-474 cloning cable 6
cation cable, OPC-1529R, is supplied with the software. Used for handheld-to-handheld cloning.
• OPC-1529R data communication cable 7
• BC-139 desktop charger
Rapidly charges BP-217 Li-ion battery pack in 2.5 hrs.
Allows you to GPS operation in DV mode operation. 8
• SP-13 earphone 9
• BP-216 battery case Provides clear receive audio in noisy environments.
Battery case for R6 (AA) × 2 alkaline batteries. 10
• BP-217 li-ion battery pack • LC-163 carrying case 11
7.4 V/1500 mAh (min.), 1580 mAh (typ.) Lithium Ion battery Helps protect the transceiver from scratches, etc.
pack. Battery life: 5 hrs. (approx.; VHF, FM, high power, Tx : Rx : 12
• AD-92SMA antenna connector adapter
Standby = 1:1:8)
Allows you to connect an external antenna with a BNC 13
• HM-75A remote control microphone connector. 14
Allows you to remotely select operating channels, etc.
• HM-131 speaker-microphone 15
For operation while conveniently hanging the transceiver 16
from your belt, etc.
• HM-128/HM-153 earphone-microphone 17
Ideal for hands-free operation by clipping the microphone
18
with the PTT switch to your lapel or breast pocket.
• HS-85 headset with vox/ptt unit Microsoft® and Windows® are registered trademarks of Microsoft 19
Hands-free headset with VOX control box. Corporation in the U.S.A. and other countries.
121
15 OPTIONS

■ Optional UT-121 installation


• Upper view
RECOMMENDATION:
Critical technique is necessary for the UT-121 instal- q
lation, therefore, we recommend you to install it at UT-121
your dealer or service center. w

The optional UT-121 is installed inside the unit holder which is


located under the battery pack/case’s space. • Side view

Install the optional UT-121 as following procedures. Unit installer guide


UT-121
q Unscrew 2 screws to remove the unit cover.
• Check it clicks when the optional UT-121 is installed.
• Check the optional UT-121 is locked to the unit installer guide.

2 screws
r Check the UT-121 position where is located under the
transceiver’s chassis.
t Push both edges of the UT-121 to install it into the trans-
ceiver, then confirm to install it completely.
y Screw 2 screws to assemble the unit cover.
Unit cover

w Insert the UT-121’s fixed part to the unit holder (q), then
take down it to the unit holder (w) as the right illustration.

122
OPTIONS 15

■ Optional HM-75A REMOTE CONTROL MICROPHONE 1


The optional HM-75A allows you to remotely select operating • NORM-1: (default) 2
frequencies, memory channels, etc. [A] Selects band. 3
[B] Toggles VFO mode and memory mode.
Remote control functions can be selected from 3 settings. 4
[Y] Frequency or memory channel “UP”.
These can be selected with “MIC SIMPLE MODE” in set
mode. (p. 89)
[Z] Frequency or memory channel “DOWN”. 5
MENU screen ➪ SET MODE ➪ MIC SIMPLE MODE 6
(Push [MENU/LOCK]) (Rotate [DIAL]†, then push [ï](5)†.) • NORM-2:
[A] Toggles the monitor function. 7
Transmit LED Microphone [B] Toggles VFO mode and memory mode. 8
PTT switch
A [Y] Frequency or memory channel “UP”.
B
[Z] Frequency or memory channel “DOWN”. 9
10
Speaker • SIMPLE:
OFF ON
11
LOCK
[A] Toggles the monitor function.
[B] Selects call channel C0. 12
• Selects memory channel 000 in memory mode.
[Y]
• Volume “UP” while operating the monitor function.
13
Earphone jack
[Z]
• Selects memory channel 001 in memory mode. 14
• Volume “DOWN” while operating the monitor function.
The HM-75A has a lock switch on the backside to prevent ac- 15
cidental frequency changes, etc. VFO mode cannot be selected via the microphone when 16
SIMPLE mode is selected.
Be sure to turn power OFF when plugging the HM-75A to 17
the [MIC/SP] jacks. SIMPLE mode can select only 3 channels and is useful for 18
group operations during touring, etc.
19
†[DIAL] ↔ [∫
∫](2)/[√
√](8) [ï](5) ↔ [≈
≈](6)
123
16 CE
Versions of the IC-E91 which display the “CE”
INSTALLATION NOTES symbol on the serial number seal, comply with the
essential requirements of the European Radio and
Telecommunication Terminal Directive 1999/5/EC.
• When transmitting with a portable radio, hold the radio in a
vertical position with its microphone 2.5 to 5 centimeters This warning symbol indicates that this equipment
away from your mouth. Keep antenna at least 2.5 centime- operates in non-harmonised frequency bands
ters from your head and body. and/or may be subject to licensing conditions in
• If you wear a potable two-way radio on your body, ensure the country of use. Be sure to check that you have
that the antenna is at least 2.5 centimeters from your body the correct version of this radio or the correct pro-
when transmitting. gramming of this radio, to comply with national li-
censing requirement.

124
CE 16

1
2
DECLARATION 3
OF CONFORMITY 4
5
We Icom Inc. Japan
1-1-32, Kamiminami, Hirano-ku 6
Osaka 547-0003, Japan
Declare on our sole responsibility that this equipment complies with the Düsseldorf 21st Apr. 2006
7
essential requirements of the Radio and Telecommunications Terminal
Equipment Directive, 1999/5/EC, and that any applicable Essential Test
Place and date of issue 8
Suite measurements have been performed.
Icom (Europe) GmbH 9
Kind of equipment: VHF/UHF FM TRANSCEIVER Himmelgeister straße 100
D-40225 Düsseldorf
10
Type-designation: iE91 Authorized representative name 11
H. Ikegami
General Manager 12
Version (where applicable):
This compliance is based on conformity with the following harmonised
13
standards, specifications or documents: 14
i) EN 301 489-1
ii) EN 301 489-15 Article 3.1b
15
iii) EN 301 783-2 Article 3.2 16
iv) EN 60950-1: 2001 Signature
v) 17
18
19
125
#22 Europe <Intended Country of Use>
­ ■ GER ■ FRA ■ ESP ■ SWE
■ AUT ■ NED ■ POR ■ DEN
■ GBR ■ BEL ■ ITA ■ FIN
■ IRL ■ LUX ■ GRE ■ SUI
■ NOR

#23 UK <Intended Country of Use>


­ ■ GER ■ FRA ■ ESP ■ SWE
■ AUT ■ NED ■ POR ■ DEN
■ GBR ■ BEL ■ ITA ■ FIN
■ IRL ■ LUX ■ GRE ■ SUI
■ NOR

#24 Italy <Intended Country of Use>


■ GER ■ FRA ■ ESP ■ SWE
■ AUT ■ NED ■ POR ■ DEN
■ GBR ■ BEL ■ ITA ■ FIN
■ IRL ■ LUX ■ GRE ■ SUI
■ NOR

#30 France <Intended Country of Use>


■ GER ■ FRA ■ ESP ■ SWE
■ AUT ■ NED ■ POR ■ DEN
■ GBR ■ BEL ■ ITA ■ FIN
■ IRL ■ LUX ■ GRE ■ SUI
■ NOR

A-6503H-1EU-wa
Printed in Japan
© 2006–2012 Icom Inc.
Printed on recycled paper with soy ink. 1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan