Professional Documents
Culture Documents
HIV Glass Insulator Catalogue
HIV Glass Insulator Catalogue
HIV Glass Insulator Catalogue
IV
Toughened Glass Insulator
Figure No. 1 2 3 1 3 3 3
Impact strength Nm 5 5 6 6 6 6 6
Dry kV 55 55 70 70 70 70 70
Power Freq. Withstand
Volt. Wet kV 30 30 40 40 40 40 40
Dry Lighting Impulse Withstand Volt. kV 75 75 100 100 100 100 100
Mass per 100 pcs kg 280 250 370 390 380 410 420
Website:www.hivoltinsulators.com E-mail:hivoltinsulators@gmail.com
Tel : +86 411 62655875 Fax:+86 411 39858800 ext. 0075
-2-
Hivolt Insulators Co., Ltd.
“ We light up the world ! ”
Figure No. 4 5 6 6 6
Coupling Size 20 20 20 24 24
Impact strength Nm 6 10 10 10 10
Dry kV 70 75 75 75 75
Power Freq. Withstand
Volt. Wet kV 40 45 45 45 45
Dry Lighting Impulse Withstand Volt. kV 100 110 110 110 110
Website:www.hivoltinsulators.com E-mail:hivoltinsulators@gmail.com
Tel : +86 411 62655875 Fax:+86 411 39858800 ext. 0075
-3-
Hivolt Insulators Co., Ltd.
“ We light up the world ! ”
Figure No. 7 8 7 8 8 9
Impact strength Nm 5 6 6 7 7 10
Dry kV 60 80 80 80 80 80
Power Freq. Withstand
Volt. Wet kV 30 50 50 50 50 50
Mass per 100 pcs kg 250 370 390 420 450 620
Website:www.hivoltinsulators.com E-mail:hivoltinsulators@gmail.com
Tel : +86 411 62655875 Fax:+86 411 39858800 ext. 0075
-4-
Hivolt Insulators Co., Ltd.
“ We light up the world ! ”
Fig. 10
Type LXQY-70 LXQY-80 LXQY-100 LXQY-120
Figure No. 10 10 10 10
Impact strength Nm 7 7 7 7
Dry kV 70 70 70 70
Power Freq. Withstand
Volt. Wet kV 40 40 40 40
Website:www.hivoltinsulators.com E-mail:hivoltinsulators@gmail.com
Tel : +86 411 62655875 Fax:+86 411 39858800 ext. 0075
-5-
Hivolt Insulators Co., Ltd.
“ We light up the world ! ”
Fig. 11 Fig. 12
Figure No. 11 12 11 12 12 12
Impact strength Nm 6 6 6 6 10 10
Dry kV 80 80 80 80 80 80
Power Freq. Withstand
Volt. Wet kV 43 43 43 43 45 45
Dry Lighting Impulse Withstand Volt. kV 120 120 120 120 120 120
Power Freq. Puncture Volt. kV 130 130 130 130 130 130
Mass per 100 pcs kg 480 530 490 540 540 620
Website:www.hivoltinsulators.com E-mail:hivoltinsulators@gmail.com
Tel : +86 411 62655875 Fax:+86 411 39858800 ext. 0075
-6-
Hivolt Insulators Co., Ltd.
“ We light up the world ! ”
Fig. 13 Fig. 14
Figure No. 13 13 13 13 14 14
Impact strength Nm 10 10 10 10 10 10
Dry kV 80 90 90 90 90 90
Power Freq. Withstand
Volt. Wet kV 45 55 55 55 55 55
Dry Lighting Impulse Withstand Volt. kV 120 135 135 135 135 135
Power Freq. Puncture Volt. kV 130 130 130 130 130 130
Mass per 100 pcs kg 700 880 920 1220 540 1430
Website:www.hivoltinsulators.com E-mail:hivoltinsulators@gmail.com
Tel : +86 411 62655875 Fax:+86 411 39858800 ext. 0075
-7-
Hivolt Insulators Co., Ltd.
“ We light up the world ! ”
Fig. 15
Figure No. 15 15 15 15
Dry kV 70 75 75 75
Power Freq. Withstand
Volt. Wet kV 40 45 45 45
Website:www.hivoltinsulators.com E-mail:hivoltinsulators@gmail.com
Tel : +86 411 62655875 Fax:+86 411 39858800 ext. 0075
-8-