National Institute of Technolo Rourkela
Department of Electrical Engineerin:
To study the single phase full controlled bridge converter with R & R-L load.
Name of The Equipment ‘Specification
‘Single Phase Full Controlled Converter Kit
‘Single phase VARIAC O-270V,15A, 40SKVA
Rheostat 0-100
Taductor O-100mFT
Voltmeter 0-300V, PMMC
“Ammeter O-5A, PMC
Differential Probe & Current Probe 20:1 & TOOmVIA
DSO with probe 2 Channel, SOMHz, 1GSals
230V AC,
amne(ay
‘Theory:
The full controlled rectifier has four thyristors. During positive half cycles of input voltage, thyristors T; and Ty
are triggered at ota. The load is connected to source through T; & Ts. Similarly in negative half cycle of input
voltage, Tr & Ts get forward biased and triggered at o=n+a, It tends to apply the supply voltage across thyristors Ty &
T, as reverse blocking voltage. T, & Ty are tuned off due to line or natural commutation and the load current is
transferred from T, & Ty to T2 & T3.The average output voltage can be found using below formula:=
avr
Vavg= "coset
The VARIAC position must be at zero before switching ON the circuit,
“The firing circuit knob position should be at 180° before start.
{Consult with teacher before switching ON the circuit,Procedure:-
Connect the circuit with R load/R-L load as shown in the circuit diagram.
4 Switch ON the power supply and gradually increase the voltage up to 100V by VARIAC.
Vary the firing angle by the controller from 0° to 180° in steps as instructed.
+ Note down the voltage and current readings from meters.
Observe & take the voltage and current waveform in DSO.
Observation Table:-
‘SLNo. | Firing Angle Vo To Vow
(@in’) (in Volts) (in Amps) (Calculated) | (Vege Vo)X100
(in Volts) Vive
1. 0 qT
2. 30
3. 60
4. 90
5. 120
6. 150
7 180
To be written by the student,
Waveforms of fully-controlled converter with (a) R-load and (b) RL load.
oe