INTERNATIONAL UNIVERSITY STRUCTURAL STRENGTHENING

Given:

Circular Column D ≔ 500 mm

Requires an additional 30% of ϕ ⋅ Pn

f'c ≔ 40 MPa

fy ≔ 410 MPa

β ≔ 0.85 ϕ ≔ 0.7 tf ≔ 0.30 mm d ≔ 25 mm n≔8

π ⋅ D2 π ⋅ d2
Ag ≔ ―― = 0.196 m 2 Ast ≔ n ⋅ ――= 3927 mm 2
4 4
Step 1: Find the load bearing of column

Pn ≔ β ⋅ ⎛⎝0.85 ⋅ f'c ⋅ ⎛⎝Ag - Ast⎞⎠ + ⎛⎝fy ⋅ Ast⎞⎠⎞⎠ = 6929.568 kN

ϕ ⋅ Pn = 4850.698 kN

Pnreq ≔ 1.30 ⋅ Pn = 9008.438 kN

ϕ ⋅ Pnreq = 6305.907 kN

Find the strength of FRPP require

⎛ ϕ ⋅ Pnreq ⎞
⎜――― - Ast ⋅ fy⎟
⎝ ϕ⋅β ⎠
f'cc ≔ ――――――= 54.953 MPa
0.85 ⋅ ⎛⎝Ag - Ast⎞⎠

Step 2: Determine maximum confining pressure due to CFP ( fL )


ប����ន��យ៖បណ�ត �� � ��ណត� -1-
INTERNATIONAL UNIVERSITY STRUCTURAL STRENGTHENING

Step 2: Determine maximum confining pressure due to CFP ( fL )

Ka ≔ 1 Circular column
f'cc - f'c
fL ≔ ――― = 4.531 MPa
3.3 ⋅ Ka
Step 3: compute the design FRP

CE ≔ 0.95 for interior environment from table

fu ≔ 3792 MPa

εfu ≔ 0.0167

ε'fu ≔ CE ⋅ εfu = 0.016

Step 4: Determine the Number of plies

φ ≔ 0.95 Strength reduction factor for wrapped section

kε ≔ 0.55 Efficiency factor

εf ≔ kε ⋅ εfu = 0.009

Ef ≔ 227527 MPa

ψ ≔ 0.95
fL ⋅ D
n ≔ ――――― = 1.902
ψ ⋅ 2 ⋅ Ef ⋅ tf ⋅ εf
n≔2
Step 5: Verify the ultimate axial strain of the confine concrete

ε'c ≔ 0.002 kb ≔ 1 Circular column

⎛ fL ⎛ εf ⎞ 0.45⎞
εcuu ≔ ε'c ⋅ ⎜1.5 + 12 kb ⋅ ―⋅ ⎜―⎟ ⎟ = 0.008
⎜⎝ f'c ⎝ ε'c ⎠ ⎟⎠

εcuu ≔ ‖ if εcuu < 0.01 | | = “prevent accessive cracking”


‖ ||
‖ ‖‖ “prevent accessive cracking” | |
‖ else ||
‖ ||
‖ ‖‖ “column crack” | ||

ប����ន��យ៖បណ�ត �� � ��ណត� -2-