STRUCTURAL PILE ANALYSIS REPORT

For
GENEX INVESTMENT
At

UTTAR DOKHA, KATHMANDU

Submitted By
Sanju Jain Geotech Firm (P) Ltd
Bagdol, Lalitpur, Nepal
Email: sconsortium.sanju@gmail.com
Cell 9851118335
May, 2022
GENEX INVESTMENT Project-Structural Pile Calculation reports
UTTAR DHOKA

TABLE OF CONTENTS
1. Vertical Analysis of Single Bored Pile ................................................................................ 2

1.1. Downward (Compression) Load Capacity Calculation ................................................. 2

1.1.1 Ultimate tip resistance: ....................................................................................................... 2

1.1.2 Ultimate side resistance: .................................................................................................... 3

1.1.3 Skin friction of cohesion less soil: ....................................................................................... 3

1.1.5 Negative Side Resistance .................................................................................................. 5

1.2. Maximum Settlement Calculation at Ultimate Vertical Resistance .............................. 5

1.2 Relationship between Settlement and Vertical Load .................................................... 6

1.3 Total, Side and Tip Resistance vs. Settlement ............................................................ 69

1.4 Uplift Load Capacity Calculation .................................................................................. 70

1.5 Lateral Analysis .............................................................................................................. 71

1.5.1 Lateral Deflection Calculation ....................................................................................... 71

2. SUMMARY OF CRITICAL BOREHOLE 1, 2 AND 3 AND BASEMENT EXCAVATION

DEPTH 73

3. STRUCTURAL PILE CALCULATION REPORTS FOR BOREHOLE 1 AND 3 FOR

Ø500mm AND Ø600mm- 12, 14 AND 16M LONG ............................................................................ 77


GENEX INVESTMENT Project-Structural Pile Calculation reports
UTTAR DHOKA

1. Vertical Analysis of Single Bored Pile


The analysis procedures was adopted as described in the Foundations & Earth Structures, Design
Manual 7.02, published by Department of Navy, Naval Facilities Engineering Command.
1.1. Downward (Compression) Load Capacity Calculation
Ultimate downward capacity can be determined by the following equations: 𝑄𝑑𝑤 = 𝑄𝑡𝑖𝑝 + 𝑄𝑠𝑖𝑑𝑒
Where Qdw = ultimate downward capacity
Q tip = ultimate tip resistance Qside =
ultimate side resistance

1.1.1 Ultimate tip resistance:

𝑄𝑡𝑖𝑝 = 𝐴𝑡𝑖𝑝 . 𝑄𝑢𝑙𝑡 = 𝐴𝑡𝑖𝑝 (𝑁𝑞 𝑆𝑣 + 𝑁𝑐 )


Where Atip = area of pile tip
qult= ultimate end bearing pressure
Sv = vertical stress in soil (overburden pressure)
Nq = bearing factor for cohesionless soils. It is a function of friction
shown in Table 1-1.
Nc = bearing factor for cohesive soils. It is a function of z/B
(depth/width) shown in Table 1-2.
Table 1-1. Bearing Capacity Factor, Nq
� Nq Nq
(Internal friction) (Displacement (Non-Displacement
pile) pile)
26 11.0 5.6

28 15.2 7.6

30 21.0 10.3

31 24.6 12.1

32 29.1 14.2

33 34.5 16.9

34 41.3 20.3

35 49.9 24.6

36 60.9 30.1

37 75.0 37.1

38 93.0 46.1

39 116.1 57.7
GENEX INVESTMENT Project-Structural Pile Calculation reports
UTTAR DHOKA

40 145.4 72.3

Table 1-2. Bearing Capacity Factor, Nc


z/B Nc
(Depth/Width)
0 6
.
1 73
.
2 88
.
3 84
.
4 89
>4 9

1.1.2 Ultimate side resistance:


𝑄𝑠𝑖𝑑𝑒 = ∑ 𝑆𝑓 𝑃𝑖 ∆𝑙 = ∑(𝑓𝑜 + 𝐶𝑎 )𝑃𝑖 ∆𝑙

Where Sf = side resistance


f0 = skin friction of cohesionless soil Ca =
adhesion of cohesive soil
Pi = Perimeter of pile section
l = segment of pile

1.1.3 Skin friction of cohesion less soil:


𝑓𝑜 = 𝑆ℎ 𝑇𝑎𝑛(𝑑) = 𝐾𝑑𝑜𝑤𝑛 . 𝑆𝑣 . 𝑇𝑎𝑛(𝛿)
𝑆ℎ
𝐾𝑑𝑜𝑤𝑛 = 𝑆𝑣
𝑜𝑟 𝑆ℎ = 𝐾𝑑𝑜𝑤𝑛 . 𝑆𝑣

Where
Sv = vertical stress in soil
Sh = horizontal stress in soil

Kdown = ratio of Sh/Sv.


d = skin friction between soil and pile. It is a function of pile skin materials.
For concrete pile, d = Kf . Where Kf is friction factor ranging from 0.1 to 1.
GENEX INVESTMENT Project-Structural Pile Calculation reports
UTTAR DHOKA

Adhesion of cohesive soil:


𝐶𝑎 = 𝐾𝑐 . 𝐾𝑎 . 𝐶
Where C = shear strength of cohesive soil (cohesion)
Kc = adhesion factor ranging from 0.1 to 1,.
Ka = Adhesion ratio, Ca/C, which is a function of C shown in Figure 1-1. If Ka =1, then calculation in Fig. 1-1 is
bypassed.

Adhesion Ratio Ka
1.5

1.25

1 All Piles
Ratio Ka=Ca/C

Concrete Pile

0.75

0.5

0.25

0
0 1000 2000 3000 4000
Cohesion C, Psf

Figure 1-1. Adhesion Ratio, Ka

Limited Depth of side resistance and end bearing :


Experience and field evidence indicate that the side friction and end bearing increase with vertical stress Sv up to
a limiting depth of embedment. Beyond this limiting depth (10D to 20D, B = Pile width), there is very little increase in
side friction and end bearing. Penetration Ratio, PR, is used to define the limiting depth. PR = 20 is commonly
used for both side friction and end bearing..
PRtip = (z/D)tip, Penetration ration for calculation of end bearing.
PR f = (z/D)f, Penetration ration for calculation of side friction.
Where z = depth
D = average pile width
The limitation of side friction and end bearing also can be expressed as absolute value for both cases. The
GENEX INVESTMENT Project-Structural Pile Calculation reports
UTTAR DHOKA

values can be changed in the table of Advanced Page.


q_ limit, Limit of end bearing pressure.
f0_ limit, Limit of sum of side friction and adhesion.
Allowable downward capacity can be determined by the following equation:
1.1.5 Negative Side Resistance
Piles installed through compressive soils can experience “down drag” forces or negative resistance along the shaft,
which results from downward movement (settlement) of adjacent soil. Negative resistance results primarily from
consolidation of soft deposits caused by dewatering or fill placement. The down drag force is the sum of negative
friction and adhesion. It does not include tip resistance. It only effects downward capacity, not uplift capacity.
However, this effect is not considered in the calculation as the borelog data does not indicate soft soil deposit by
dewatering or fill placement.
Down drag Force from Negative Friction:
𝑄𝑛𝑒𝑔 = 𝐾𝑛𝑒𝑔 . ∑(𝑓𝑜 )𝑃𝑖 ∆𝑙 = 𝐾𝑛𝑒𝑔 . ∑(𝑆𝑓 + 𝐶𝑎 )𝑃𝑖 ∆𝑙

Where Q neg = Down drag force from negative side friction


Kneg = Negative side friction factor. It ranges from 0 to 1 depending on the impact of settlement of the soil to the
pile shaft.
Sf = side resistance
f0 = skin friction of cohesion less soil
Ca = adhesion of cohesive soil
Pi = Perimeter of pile section
l = segment of pile

1.2. Maximum Settlement Calculation at Ultimate Vertical Resistance


Vesic’s method(1977) is adopted in calculating Maximum settlement. The settlement at the top of the pile consists
of the following three components:
a) Settlement due to axial deformation of pile shaft, Xs
∆𝑙
𝑋𝑠 = ∑(𝑄𝑡𝑖𝑝 + 𝑄𝑠𝑖𝑑𝑒 )
𝐴′ 𝐸
Where
Qtip = tip ultimate resistance Qside = side ultimate resistance
Δ l = pile segment
A’ = effective pile cross sectional area
E = modulus of elasticity of the pile

The equation is different from what shown in DM-7. This equation uses numerical integration, which is more
accurate than the empirical equation in DM-7.

b) Settlement of pile point caused by load transmitted at the point, Xpp


𝐶𝑝 𝑄𝑡
𝑋𝑝𝑝 =
𝐵𝑄𝑢𝑙𝑡
Where Cp = empirical coefficient depending on soil type and method of construction. It is defined in
GENEX INVESTMENT Project-Structural Pile Calculation reports
UTTAR DHOKA

Table 8-3 below.


B = pile diameter
qult= ultimate end bearing pressure

Table 8-3. Typical Value of Cp for Settlement Analysis


Soil Type Driven Piles Drilled Piles
Sand 0.03 0.135
Clay 0.025 0.045
Silt 0.04 0.105

c) Settlement of pile point caused by load transmitted along the pile shaft, Xps
𝐶𝑠 𝑄𝑠
𝑋𝑝𝑠 =
𝐿𝑒 𝑄𝑢𝑙𝑡
Where Le = embedded depth
qult= ultimate end bearing pressure Qs =
side resistance

𝑍
𝐶𝑠 = (0.93 + 0.16)√ 𝐶𝑝
𝐵

Where z/B = depth / pile width

Hence, Total settlement of a single pile, Xtotal


𝑋𝑡𝑜𝑡𝑎𝑙 = (𝑋𝑠 + 𝑋𝑝𝑝 + 𝑋𝑝𝑠 )

1.2 Relationship between Settlement and Vertical Load


Vertical load and settlement relation was developed from t-z (side load vs shift movement) and q-w (bearing load
vs base settlement) curves. The t-z curve represents the relation between side resistance and relative movement
within soil and shaft. The t-z curve can vary at different depth and in different soils. The q-w curve represents
the relation between tip resistance and base movement of the shaft.
t-z and q-w Relation
Generally, t-z and q-w relations require a considerable amount of geotechnical data from field and laboratory
tests, which are not always available for engineers. The following procedures adopted to determine the amount
of settlement:
1. First, calculate ultimate side resistance and ultimate tip resistance of shaft using the methods introduced
in 1.1.1.5.
2. Find relationships between settlement and load transfer ratios (developed resistance against
ultimate resistance) using the corresponding charts as shown in Fig 1-2 – 1-5
3. Integrate both side and tip resistances, as well as elastic compression of shaft body, to obtain total
vertical resistance as a function of settlement.
4. From the relationships between settlement and load transfer ratios, we can develop t-z and q-w curve.
GENEX INVESTMENT Project-Structural Pile Calculation reports
UTTAR DHOKA

Typical settlement against load transfer ratios are shown in Figures 1-2 through 1-5 proposed by Reese
and O’Neal (1988). Figure 1-2 and 1-3 represent the side load transfer ratio for cohesive soils and
cohesion less soils/gravel respectively. Figure 1-4 and 1-5 represent the end bearing load transfer ratio
for cohesive soils and cohesive less soils respectively.

Figure 1-2 Normalized load transfer


relations for side resistance in cohesive
soil (Reese and O'Neill, 1989)
GENEX INVESTMENT Project-Structural Pile Calculation reports
UTTAR DHOKA

Figure 1-3 Normalized


load transfer relations for
side resistance in
cohesionless soil (Reese
and O'Neill, 1989)

Figure 1-4. Normalized load


transfer relations for base
resistance in cohesive soil
(Reese and O'Neill, 1989)
GENEX INVESTMENT Project-Structural Pile Calculation reports
UTTAR DHOKA

Figure 1-5. Normalized


load transfer relations for
base resistance in
cohesionless soil (Reese
and O'Neill, 1989)

1.3 Total, Side and Tip Resistance vs. Settlement


Figure 1-6 shows the vertical load is distributed in to side resistance and tip resistance. The chart from results
of program shows that side resistance develops at small settlement, while tip resistance develops at large
settlement. The ultimate value of the two cannot simply be added together. That is why tip resistance requires
large Factor of Safety to get allowable capacity.

Figure 1-6. Total, Side and Tip Resistance vs. Settlement

69 | P a g e
GENEX INVESTMENT Project-Structural Pile Calculation reports
UTTAR DHOKA

Capacity at Allowable Settlement


Allowable settlement Qallow calculated as defined by Factor of Safety presented in Section 1.4. The other
method is defined by allowable settlement.

1.4 Uplift Load Capacity Calculation


Ultimate uplift capacity can be determined by the following equations:

Qup = Qw + Qside

Where Qw = weight of pile


Qside = ultimate side resistance
Qw =∑Wi Δl
Where ∑Wi = weight of pile section in unit length
Δl = segment of pile

𝑄𝑠𝑖𝑑𝑒 = ∑ 𝑆𝑓 𝑃𝑖 ∆𝑙 = ∑(𝑓𝑜 + 𝐶𝑎 )𝑃𝑖 ∆𝑙

Where Sf = side resistance


f0 = skin friction of cohesionless soil
Ca = adhesion of cohesive soil
l = segment of pile
Pi = Perimeter of pile section
f0 = Kup ·Sv tan(d)
𝑆ℎ
𝐾𝑢𝑝 = 𝑜𝑟 𝑆ℎ = 𝐾𝑢𝑝 . 𝑆𝑣
𝑆𝑣
Where
Sv = vertical stress in soil
Sh = horizontal stress in soil
Kup = ratio of Sh/Sv which is defined in the table of Setup
d = skin friction between soil and pile. It is function of pile side materials. For steel pile, d = 20o-30o. For
concrete pile, d = Kf? . Kf is a friction factor ranging from 0.1 to 1. Kf can be defined in in the table of
Setup.
𝐶𝑎 = 𝐾𝑐 . 𝐾𝑎 . 𝐶

Where C = shear strength of cohesive soil (cohesion)


Kc = adhesion factor ranging from 0.1 to 1, defined in the table of Setup.

70 | P a g e
GENEX INVESTMENT Project-Structural Pile Calculation reports
UTTAR DHOKA

Ka = Adhesion ratio, Ca/C, which is a function of C shown in Figure 8-1.

Allowable Uplift Capacity can be determined by following equations:


𝑄𝑤 𝑄𝑠𝑖𝑑𝑒
𝑄𝑎𝑙𝑙𝑜,𝑈 = +
𝐹𝑆𝑤 𝐹𝑆𝑢𝑝
Where Qw = weight of pile
Qside = ultimate side uplift resistance
FS_w = factor of safety for pile weight, defined in the table of Advanced Page.
FS_up = factor of safety for side resistance for uplift, defined in the table of Advanced Page
Step 1. Calculate Capacity of Individual Pile, Q single
Qsingle can be calculated using the methods mentioned in above sections.
Qsingle includes side resistance and tip resistance.

1.5 Lateral Analysis


Lateral capacity calculation involves the method mentioned in FHWA-SA-91- 048, COM624P Laterally Loaded Pile
Program for the Microcomputer, Version 2.0, by Wang and Reese (1993). As per the Wanf and reese method the
theoretical background on which the calculation is based for lateral deflection calculation are mentioned below.

1.5.1 Lateral Deflection Calculation


The Calculation uses the four nonlinear differential equations to perform the lateral analysis which are:
𝑑4 𝑌 𝑑2 𝑌
𝐸𝐼 + 𝑄 − 𝑅 − 𝑃𝑞 = 0
𝑑𝑍 4 𝑑𝑍 2

Where Q = axial compression load on the pile


Y = lateral deflection of pile at depth of Z Z = depth from top of pile
R = soil reaction per unit length E = modules of elasticity of pile I = moment of inertia of the pile
Pq = distributed load along the length of pile

𝑑3 𝑌 𝑑𝑌
𝐸𝐼 3
+𝑄 =𝑃
𝑑𝑍 𝑑𝑍
Where P = shear in the pile
Where M = bending moment of the pile
𝑑𝑌
= 𝑆𝑡
𝑑𝑍
Where St = slope of the elastic curve defined by the axis of pile
𝑑2 𝑌
𝐸𝐼 ( 2 ) = 𝑀
𝑑𝑍

71 | P a g e
GENEX INVESTMENT Project-Structural Pile Calculation reports
UTTAR DHOKA

The output of Shear, moment and deflection using the nonlinear differential equations representing the behavior of
the pile -soil system to lateral (shear and moment) loading conditions in a finite difference formulation using Reese’s
p-y method of analysis is presented above in Figure 1-8. For each set of applied boundary loads the program
performs an iterative solution which satisfies static equilibrium and achieves an acceptable compatibility between
force and deflection (p and y) in every element.

Step 1. Calculate Deduction Factor Rside and Rfront


Assuming the lateral load P is in X direction. Please note that Rfront is not the same as Rside.
Table 1-4. Deduction Factor Rfront
Sx Rfront
>8D 1
8D 1
6D 0.8
4D 0.5
3D 0.4
<3D 0.4

Table 1-5. Deduction Factor Rside


Sy Rside
>3D 1
3D 1
2D 0.6
1D 0.3
<1D 0.3

72 | P a g e
GENEX INVESTMENT Project-Structural Pile Calculation reports
UTTAR DHOKA

Note: D = pile diameter Reference: FHWA HI 97-013

Step 2. Reducing Soil Lateral Resistance by Applying the Deduction Factors from Step 1
Combine the reduction factors and apply them to p-y curve for lateral analysis.
Step 3. Calculate P-yt (the Lateral Capacity and Deflection) of Each Individual Piles
Calculate the lateral capacity of each pile and get P-Yt curve for all piles.

2. SUMMARY OF CRITICAL BOREHOLE 1, 2 AND 3 AND BASEMENT


EXCAVATION DEPTH
73 | P a g e
COMPARISON OF BORELOG SOIL PROFILE DATA FROM SOIL TEST REPORT
Depth BH1 BH2 BH3
below Soil Description-BH1 Soil Description-BH12 Soil Description-BH12
EGL. N-Value N-Value N-Value
0.0 Filling Materials 11 Filling Materials 10 Filling Materials 12
1.5 Filling Materials 11 Filling Materials 10 Filling Materials 12
3.0 Greyish Brownish Yellowish Colour Silty Coarse Sand 9 Dark Greyish Colour Silty Sandy Coarse sand 4 Dark Greyish Colour Silty Clay 16
4.5 Greyish Brownish Yellowish Colour Silty Coarse Sand 16 Dark Greyish Colour Silty Sandy Coarse sand 29 Dark Greyish Colour Silty Clay 20
6.0 Greyish Colour Silty Coarse Sand 50 Dark Greyish Colour Silty Sandy Coarse sand 23 Greyish Colour Silty Sandy Clay 31
7.5 Greyish Colour Silty Coarse Sand 11 Dark Greyish Colour Silty Sandy Coarse sand 33 Greyish Colour Silty Sandy Coarse Sand 25
9.0 Dark Greyish Colour Silty Clay 7 Drak Greyish Colour Clay Silty 11 Greysih Colour Silty sand Mix Clay 9
10.5 Dark Greyish Colour Silty Clay 11 Drak Greyish Colour Clay Silty 12 Dark Greyish Colour Silty Clay 12
12.0 Dark Greyish Colour Silty Clay 10 Drak Greyish Colour Clay Silty 8 Dark Greyish Colour Silty Clay 10
13.5 Dark Greyish Colour Silty Clay 27 Drak Greyish Colour Clay Silty 11 Dark Greyish Colour Silty Clay 18
15.0 Dark Greyish Colour Silty Clay 24 Drak Greyish Colour Clay Silty 27 Dark Greyish Colour Silty Clay 23
16.5 Dark Greyish Colour Silty Clay 26 Drak Greyish Colour Clay Silty 25 Dark Greyish Colour Silty Clay 25
18.0 Dark Greyish Colour Silty Clay 27 Drak Greyish Colour Clay Silty 23 Dark Greyish Colour Silty Clay 17
19.5 Dark Greyish Colour Silty Clay 24 Drak Greyish Colour Clay Silty 24 Dark Greyish Colour Silty Clay 20
20.0 Dark Greyish Colour Silty Clay 24 Drak Greyish Colour Clay Silty 24 Dark Greyish Colour Silty Clay 20

COMPARISON OF BORELOG DATA AND WATER PRESSURE


0 5 10 15 20 25 30 35 40 45 50 55
0.0 0
1.0
0
2.0
3.0 0
4.0 RECOMMENDATION FOR DESIGNING OF FOUNDATION PILE
0
5.0 BH3 seems critical for basement excavation @ 6m below EGL
6.0 0 50 and BH1 shouls be considered for basement excavation @4.2m
7.0 below EGL
11 33
8.0
9.0 7 11
10.0
1112
11.0
12.0 8 10
13.0
11 27
14.0 BH1
15.0 24 27
BH2
16.0
25 26
17.0 Excavation Line-1
18.0 23 27
BH3
19.0
24
24
20.0 24
24 Excavation Line-2
21.0
A B C D E F

4625 4820 6190 1450 3525

5675

BH-1
UP
MAT:-800mm Assumed for pile tip location
5950

LIFT LIFT
Total:- 4200mm

PARKING
17226 x 15030
56'6" x 49'4"
FFL: -3000
SSL: -3100
2

RAMP CLEAR
3410 MM WIDE
GRADIENT - 1:6

BH-3
PARKING PIT BELOW
BH-2 PARKING PIT BELOW
8330

FIRE TANK BELOW FFL: -5250 UG TANK BELOW FFL: -5250


CAPACITY - 50,000L CAPACITY - 50,000L SSL: -5400
SSL: -5400
MAT:-600mm Assumed for pile tip location
SSL: -5400
SSL: -5400 Total:- 6000mm
MAT:-600mm Assumed for pile tip location
MAT:-600mm Assumed for pile tip location
Total:- 6000mm
Total:- 6000mm

1
GENEX INVESTMENT Project-Structural Pile Calculation reports
UTTAR DHOKA

3. STRUCTURAL PILE CALCULATION REPORTS FOR BOREHOLE 1 AND 3 FOR


Ø500mm AND Ø600mm- 12, 14 AND 16M LONG

77 | P a g e
SUMMARY OF RCC PILE DESIGN FOR GENEX INVESTMENT PROJECT
Lateral Lateral Helical Control
Load Load Longitudinal Rebar
Ultimate Stirrups Stirrups
Clear Ultimate Allowable Carrying Carrying
Grad Ultimate Allowable Axial Vertical
Lengt Cover Vertical Vertical Capacity of Lateral Capacity Factor of
Bored e of Uplift Load Uplift Load Stiffness Load Main
Bore h of from Load Load Pile for Stiffness from FEM Safety in Thro Thro
Pile, Ø, Conc Carrying Carrying of Pile, Carrying Thro Thro Spac Ø, Rebar
ole Pile, Main Carrying Carrying 25mm of Pile, of Pile for RCC bars bars Ø, Spacin %
mm rete, Capacity of Capacity of EA/L, Capacity bars, bars, ing, m
m Bars Capacity, Capacity, deflection KN/mm 25mm design Ø, Ø, mm g, mm
fck, Pile, KN Pile, KN KN/mm from Nos Nos mm m
(mm) KN KN under deflection mm mm
FEM, KN
Ultimate after RCC
Vertical veritificati
1 500 12 75 M25 720.12 437.97 490.430 267.980 295.000 409.062 11.847 295.000 437.970 1.50 6 20 6 25 10 175 16 1000 1.79%
1 500 14 75 M25 772.41 472.82 550.350 301.740 295.000 350.624 11.847 295.000 472.820 1.50 6 20 6 25 10 175 16 1000 1.79%
1 500 16 75 M25 826.58 508.93 612.050 336.380 295.000 306.796 11.847 335.000 479.050 1.50 6 20 6 25 10 175 16 1000 1.79%
3 600 12 75 M25 934.95 572.28 667.260 366.420 405.000 589.049 16.531 495.000 652.280 1.50 6 20 6 25 10 175 16 1000 1.24%
3 600 14 75 M25 987.47 597.66 673.120 374.810 405.000 504.899 16.531 500.000 663.120 1.50 6 20 6 25 10 175 16 1000 1.24%
3 600 16 75 M25 1052.47 641.00 748.980 418.210 405.000 441.786 16.463 515.000 667.980 1.50 6 20 6 25 10 175 16 1000 1.24%

2
Note: Young's Modulus of Concrete M25, E= 5000 𝑓𝑐𝑘 x1000, KN/m2 25,000,000.0000 KN/m
However, at least 2% of the Total number of Piles to be installed at site should be Pile load tested before Construction for its conformity
Safe Load on Piles@ 25mm displacement,tons
Safe load for uplift @ 12mm displacement, Tons
Test Shall be conducted as per IS2911-4-1985 pile load test
Vertical Load- Pile Load Test: The test load shall be maintained for 24 hours.
Initial Tests– The safe load on a single pile shall be the least of the following:
(i) 2/3rd of the final load at which the total displacement attains a value of 12 mm unless otherwise required in a given case on the basis of nature and type of structure in which case,
the safe load should be corresponding to the stated total displacement permissible.
(ii) 50% of the final load at which the total displacement equals 10% of the pile diameter in case of uniform diameter piles or 7.5% of the bulb diameter in case of under reamed piles.
Uplift Load- Pile Load Test: The test load shall be maintained for 24 hours.
The safe load shall be the least of the following:
a) 2/3rd of the load at which the total displacement is 12 mm or the load corresponding to a specified permissible lift.
b) Half of the load at which the load displacement curve shows a clear break.
VERTICAL CAPACITY PILE CALCULATION Ø500mm-12m LONG
USING BH-1 DATA
VERTICAL ANALYSIS Figure 1

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

Vertical Load, Q= 437.0 -kN


Shear Load, P= 0.0 -kN
Slope Restain St= 0.00 -cm/-cm

Profile:
Pile Length, L= 12.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0

Fixed Head Condition

Drilled Pile (dia <=24 in. or 61 cm)

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MP -kN/m
0 10.9 31.9 47.9 164.2 0.66 16 0.0 50 3062.7 157.1 320535.8 25000 5.719
1.5 12.2 26.4 150.8 672.0 0.33 50 11.0 50 3062.7 157.1 320535.8 25000 5.719
3.0 10.6 27.2 32.6 96.3 0.83 11 12.0 50 1963.5 157.1 320535.8 25000 5.719
4.5 9.8 0.0 41.9 48.7 1.08 7
12 11.2 0.0 143.0 278.5 0.51 24

Vertical capacity:
Weight above Ground= 0.00 Total Weight= 45.54-kN *Soil Weight is not included
Side Resistance (Down)= 467.421-kN Side Resistance (Up)= 444.892-kN
Tip Resistance (Down)= 252.702-kN Tip Resistance (Up)= 0.000-kN
Total Ultimate Capacity (Down)= 720.124-kN Total Ultimate Capacity (Up)= 490.429-kN
Total Allowable Capacity (Down)= 437.965-kN Total Allowable Capacity (Up)= 267.983-kN
OK! Qallow > Q

Settlement Calculation:
At Q= 437.00-kN Settlement= 0.09606-cm
At Xallow= 2.50-cm Qallow= 686.64752-kN

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-12m
*****************************************************************
ALLPILE 6
VERTICAL ANALYSIS SUMMARY OUTPUT
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\Ø500mm-12m long

Title 1: Genex Investment


Title 2: Foundation Pile Ø500mm-12m

TOTAL LOADS:
Vertical Load, Q: 437.0 -kN
Load Factor for Vertical Loads: 1.0
Loads Supported by Pile Cap: 0 %

PILE PROFILE:
Pile Length, L= 12.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0.00 Batter Factor, Kbat= 1.00

SINGLE PILE:
Deduction factor due to Group Effect, R= 1.00
Vertical Load= 437.00 -kN

Single Pile Vertical Analysis:


Results:
Total Ultimate Capacity (Down)= 720.12-kN, Total Ultimate Capacity (Up)= 490.43-kN
Total Allowable Capacity (Down)= 437.97-kN, Total Allowable Capacity (Up)= 267.98-kN
At Work Load= 437.00-kN, Settlement= 0.09606-cm
At Work Load= 437.00-kN, Secant Stiffness Kqx= 4549.41-kN/-cm
At Allowable Settlement= 2.500-cm, Capacity= 686.65-kN
Work Load, 437.00-kN, OK with the Capacity at Allowable Settlement= 2.50-cm, Capacity= 686.65-kN
Work Load, 437.00-kN, OK with the Allowable Capacity (Down)= 437.97-kN

____________________________________________
FACTOR OF SAFETY:
FSside FStip FSuplif FSweight
2.5 2 3 1

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

Concrete poured into drilled hole.


Diameter is limited to 24in (61cm).

FOUNDATION PROFILE & SOIL CONDITIONS

Depth FOUNDATION PROPERTIES SOIL PROPERTIES Depth


from from
Ground-m Ground-m
Depth Width-cm A'-cm2 Per.-cm I'-cm4 E -MP W -kN/m Depth  -kN/m3  C-kN/m2 k-MN/m3 e50 % Nspt
0 0
0.0 50 3062.7 157.1 320535.8 25000 5.719 0.0 10.9 31.9 47.9 164.2 0.66 16
Concrete (rough) Silt (Phi + C)

1 1

1.5 12.2 26.4 150.8 672.0 0.33 50


2 Silt (Phi + C) 2

3 3
3.0 10.6 27.2 32.6 96.3 0.83 11
Silt (Phi + C)

4 4

4.5 9.8 0.0 41.9 48.7 1.08 7


5 Stiff Clay 5

6 6

7 7

8 8

9 9

10 10

11 11
11.0 50 3062.7 157.1 320535.8 25000 5.719
Concrete (rough)

12 12
12.0 50 1963.5 157.1 320535.8 25000 5.719 12.0 11.2 0.0 143.0 278.5 0.51 24
Pile Tip Stiff Clay

13 13

14 14

15 15

Batter Angle=0 (Pile diameter not to scale) Surface Angle=0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-12m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

Vertical Load vs. Settlement

800

720

640
Compression Load, Qdw -kN

560

480

400

320

240

160

80

0
0.0 0.3 0.5 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 2.8 3.0 3.3 3.5 3.8 4.0 4.3 4.5 4.8 5.0

Settlement, X -cm
Total Side Tip

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-12m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

ALLOWABLE CAPACITY vs FOUNDATION DEPTH

500 500

450 450

400 400
Compression Capacity, Qdw -kN

350 350

Uplift Capacity, Qup -kN


300 300

250 250

200 200

150 150

100 100

50 50

0 0
0 2 4 6 8 10 12 14 16 18 20 0 2 4 6 8 10 12 14 16 18 20
Foundation Depth, L -m Foundation Depth, L -m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-12m
LATERAL CAPACITY CALCULATION Ø500mm-12m
LONG USING BH-1
LATERAL ANALYSIS Figure 2

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

Vertical Load, Q= 437.0 -kN


Shear Load, P= 295.0 -kN
Slope Restain St= 0.00 -cm/-cm

Profile:
Pile Length, L= 12.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0

Fixed Head Condition

Drilled Pile (dia <=24 in. or 61 cm)

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MP -kN/m
0 10.9 31.9 47.9 164.2 0.66 16 0.0 50 3062.7 157.1 320535.8 25000 5.719
1.5 12.2 26.4 150.8 672.0 0.33 50 11.0 50 3062.7 157.1 320535.8 25000 5.719
3.0 10.6 27.2 32.6 96.3 0.83 11 12.0 50 1963.5 157.1 320535.8 25000 5.719
4.5 9.8 0.0 41.9 48.7 1.08 7
12 11.2 0.0 143.0 278.5 0.51 24
Single Pile Lateral Analysis:
Top Deflection, yt= 2.49000-cm
Max. Moment, M= 554.00-kN-m
Top Deflection Slope, St= 0.00000
OK! Top Deflection, 2.4900-cm is less than the Allowable Deflection= 2.50-cm

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
The Max. Moment calculated by program is an internal force from the applied load conditions. Structural engineer has to check whether
the pile has enough capacity to resist the moment with adequate factor of safety. If not, the pile may fail under the load conditions.

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-12m
*****************************************************************
ALLPILE 6
LATERAL ANALYSIS SUMMARY OUTPUT
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\
Ø500mm-12m long.alp
Title 1: Genex Investment
Title 2: Foundation Pile Ø500mm-12m

PILE PROFILES:
Pile Length, L= 12.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0.00

FACTORS AND CONDITIONS:


Load Factor for Vertical Loads: 1.0
Load Factor for Lateral Loads: 1.0
Loads Supported by Pile Cap: 0 %
Shear Condition: Static

SINGLE PILE:
Deduction factor due to Group Effect, R= 1.00
Vertical Load= 437.00 -kN
Shear= 295.00 -kN
Slope Restain, St= 0.00 -cm/-cm

Results:
Top Deflection, yt= 2.49000-cm
Max. Moment, M= 554.00-kN-m
Top Deflection Slope, St= 0.00000

Top Deflection, 2.4900-cm, OK with the Allowable Deflection= 2.50-cm


Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
____________________________________

Notes:
Q - Vertical Load at pile top
P - Lateral Shear Load at pile top
M - Moment at pile top
Xall - Pile top total settlement
yt - Pile top deflection
St - Pile top deflection slope (deflection/unit length)
The Max. Moment calculated by program is an internal moment of shaft due to the loading. Egineers
have to check whether the pile has enough moment capacity to resist the Max. Moment with adequate
factor of safety. If not, the pile may be damaged under the loading.
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE DEFLECTION & FORCE vs DEPTH


Single Pile, Khead=5, Kbc=2

Depth (Zp) DEFLECTION, yt -cm MOMENT -kN-m SHEAR -kN Pressure -kN/m2 Depth (Zp)
from from
Pile Top-m -5.00 0 +5.00 -1000 0 +1000 -500 0 +500 -100 0 +100 Pile Top-m
0 0

1 1

2 2

3 3

4 4

5 5
yt=0 at 5.6-m
6 6

St=0 at 6.7-m
7 7

8 8

9 9

10 10

11 11

12 12
Tip yt=-1.68E-4 Top yt=2.49E+0 Top Moment=-554.0 Top Shear=295.0
Max. yt=2.49E+0 Max. Moment=554.0 Max. Shear=300.0 Max. Pressure=53.00
Top St=1.43E-17
13 13

14 14

15 15

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-12m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE DEFLECTION vs LOADING


Single Pile, Khead=5, Kbc=2

Depth (Zp) DEFLECTION, yt -cm Depth (Zp)


from from
Pile Top-m -5.00 0 +5.00 Pile Top-m
0 0

1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

9 9

10 10

11 11

12 12
Lateral Slope Vertical yt Slope Max.
No. Load Restraint Load at Top at Top Moment
13 (kN) (cm/cm) (kN) (cm) (cm/cm) (kN-m) 13
1 29.5 0.0 437.0 0.1 0.00 32.7
2 88.5 0.0 437.0 0.4 0.00 131.0
14 3 148.0 0.0 437.0 0.9 0.00 245.0 14
4 206.0 0.0 437.0 1.5 0.00 365.0
5 236.0 0.0 437.0 1.8 0.00 425.0
15 6 266.0 0.0 437.0 2.1 0.00 487.0 15
7 295.0 0.0 437.0 2.5 0.00 554.0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-12m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE MOMENT vs LOADING


Single Pile, Khead=5, Kbc=2

Depth (Zp) MOMENT -kN-m Depth (Zp)


from from
Pile Top-m -1000.00 0 +1000.00 Pile Top-m
0 0

1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

9 9

10 10

11 11

12 12
Lateral Slope Vertical yt Slope Max.
No. Load Restraint Load at Top at Top Moment
13 (kN) (cm/cm) (kN) (cm) (cm/cm) (kN-m) 13
1 29.5 0.0 437.0 0.1 0.00 32.7
2 88.5 0.0 437.0 0.4 0.00 131.0
14 3 148.0 0.0 437.0 0.9 0.00 245.0 14
4 206.0 0.0 437.0 1.5 0.00 365.0
5 236.0 0.0 437.0 1.8 0.00 425.0
15 6 266.0 0.0 437.0 2.1 0.00 487.0 15
7 295.0 0.0 437.0 2.5 0.00 554.0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-12m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

LATERAL LOAD vs DEFLECTION & MAX. MOMENT

300 300

270 270

240 240

210 210

180 180
Lateral Load, P -kN

Lateral Load, P -kN


150 150

120 120

90 90

60 60

30 30

0 0
0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 0 60 120 180 240 300 360 420 480 540 600
Top Deflection, yt -cm Max. Moment in Single Pile, Mmax -kN-m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-12m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

P-Y curves for soils

700000

630000

560000

490000
p, -kN/m

420000

350000

280000

210000

140000

70000

0
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

y, -m
Depth: 1.5, 3.0, 4.5, 6.0, 7.5, 9.0, 10.5 -m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-12m
PILE STIFFNESS CALCULATION SHEET Ø500mm-12m LONG
USING BH-1 DATA
*****************************************************************
ALLPILE 6
PILE STIFFNESS ANALYSIS SUMMARY
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\
Ø500mm-12m long.alp
Title 1: Genex Investment
Title 2: Foundation Pile Ø500mm-12m

Single Pile Vertical Analysis:


Q= 437.00 -kN
Results:
At Work Load= 437.00-kN, Settlement, Xall= 0.15043-cm
Stiffness Kqx= 2905.10-kN/-cm

Single Pile Lateral Analysis - Free Head:

M= 0, P= 295.00 -kN
Results:
At Shear= 295.00-kN, Top Deflection, yt= 12.50000-cm
Stiffness Kpy= 23.60-kN/-cm
At Shear= 295.00-kN, Top Slope, St= -0.03760 Slope
Stiffness Kps= -7845.74-kN/Slope
Or St= -2.15330696 Degree, Stiffness Kps= -137.00-kN/Degree
P= 0, M= 10.00 -kN-m
Results:
At Moment= 10.00-kN, Top Deflection, yt= 0.01690-cm
Stiffness Kmy= 591.72-kN-m/-cm
At Moment= 10.00-kN, Top Slope, St= -0.00020 Slope
Stiffness Kms= -49019.61-kN-m/Slope
Or St= -0.01168834 Degree, Stiffness Kms= -855.55-kN-m/Degree

Single Pile Lateral Analysis - Fixed Head:


M= 0, P= 295.00 -kN
Results:
At Shear= 295.00-kN, Top Deflection, yt= 2.49000-cm
Stiffness Kpy= 118.47-kN/-cm
At Shear= 295.00-kN, Top Slope, St= 0.00000
Stiffness Kps= N/A
P= 0, M= 10.00 -kN-m
Results:
At Moment= 10.00-kN, Top Deflection, yt= 0.00000-cm
Stiffness Kmy= N/A
At Moment= 10.00-kN, Top Slope, St= 0.00000
Stiffness Kms= N/A
Notes:
Q - Vertical Load at pile top
P - Lateral Shear Load at pile top
M - Moment at pile top
Xall - Pile top total settlement
yt - Pile top deflection
St - Pile top deflection slope (deflection/unit length). Clockwise is negative
Kqx - Secant Stiffness: Vertical load vs. Vertical movement (settlement)
Kpy - Secant Stiffness: Lateral Shear vs. Lateral movement (deflection)
Kps - Secant Stiffness: Lateral Shear vs. Slope (rotation). Clockwise is negative
Kmy - Secant Stiffness: Moment vs. Lateral movement (deflection)
Kms - Secant Stiffness: Moment vs. Slope (rotation). Clockwise is negative

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
ETABS 18.1.1 License #*1VHQUC7UK2NRLHB

ETABS Concrete Frame Design


IS 456:2000 + IS 13920:2016 Column Section Design

RCC verification of 500mm Dia Pile-12m length-BH1

Column Element Details Type: Ductile Frame (Summary)


Level Element Unique Name Section ID Combo ID Station Loc Length (mm) LLRF
-3.0m C1 11 Ø500-6-Ø20+6-Ø25-Ø10-175 DL+LL 1500 1500 1

Section Properties
d (mm) h0 (mm) dc (mm) Cover (Torsion) (mm)
500 403.7 96.3 65

Material Properties
Ec (MPa) fck (MPa) Lt.Wt Factor (Unitless) fy (MPa) fys (MPa)
25000 25 1 500 500

Design Code Parameters


ɣC ɣS
1.5 1.15

Axial Force and Biaxial Moment Design For Pu , Mu2 , Mu3


Design Pu Design Mu2 Design Mu3 Minimum M2 Minimum M3 Rebar % Capacity Ratio
kN kN-m kN-m kN-m kN-m % Unitless
679.0378 13.5808 240.6207 13.5808 13.5808 2.47 0.92

Axial Force and Biaxial Moment Factors


K Factor Length Initial Moment Additional Moment Minimum Moment
Unitless mm kN-m kN-m kN-m
Major Bend(M3) 1.2 1500 199.4752 0 13.5808
Minor Bend(M2) 1.2 1500 0 0 13.5808

Shear Design for Vu2 , Vu3


Shear Vu Shear Vc Shear Vs Shear Vp Rebar Asv /s
kN kN kN kN mm²/m
Major, Vu2 68.576 174.7829 67.9438 0 554.22
Minor, Vu3 0 174.7829 67.9438 0 554.22

Joint Shear Check/Design

Revised Pile verification 500Dia-12m-BH1.EDB Page 1 of 2 5/1/2022


ETABS 18.1.1 License #*1VHQUC7UK2NRLHB

Joint Shear Shear Shear Shear Joint Shear


Force VTop Vu,Tot Vc Area Ratio
kN kN kN kN cm² Unitless
Major Shear, Vu2 N/A N/A N/A N/A N/A N/A
Minor Shear, Vu3 N/A N/A N/A N/A N/A N/A

(1.4) Beam/Column Capacity Ratio


Major Ratio Minor Ratio
N/A N/A

Additional Moment Reduction Factor k (IS 39.7.1.1)


Ag Asc Puz Pb Pu k
cm² cm² kN kN kN Unitless
1963.5 48.2 4003.7661 768.7347 679.0378 1

Additional Moment (IS 39.7.1)


Consider Length Section KL/Depth KL/Depth KL/Depth Ma
Ma Factor Depth (mm) Ratio Limit Exceeded Moment (kN-m)
Major Bending (M3 ) Yes 1 500 3.6 12 No 0
Minor Bending (M2 ) Yes 1 500 3.6 12 No 0

Notes:

N/A: Not Applicable

N/C: Not Calculated

N/N: Not Needed

Revised Pile verification 500Dia-12m-BH1.EDB Page 2 of 2 5/1/2022


VERTICAL CAPACITY PILE CALCULATION Ø500mm-14m LONG
USING BH-1 DATA
VERTICAL ANALYSIS Figure 1

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

Vertical Load, Q= 472.0 -kN


Shear Load, P= 0.0 -kN
Slope Restain St= 0.00 -cm/-cm

Profile:
Pile Length, L= 14.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0

Fixed Head Condition

Drilled Pile (dia <=24 in. or 61 cm)

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MP -kN/m
0 10.9 31.9 47.9 164.2 0.66 16 0.0 50 3062.7 157.1 320535.8 25000 5.719
1.5 12.2 26.4 150.8 672.0 0.33 50 13.0 50 3062.7 157.1 320535.8 25000 5.719
3.0 10.6 27.2 32.6 96.3 0.83 11 14.0 50 1963.5 157.1 320535.8 25000 5.719
4.5 9.8 0.0 41.9 48.7 1.08 7
14 11.2 0.0 143.0 278.5 0.51 24

Vertical capacity:
Weight above Ground= 0.00 Total Weight= 53.13-kN *Soil Weight is not included
Side Resistance (Down)= 519.708-kN Side Resistance (Up)= 497.221-kN
Tip Resistance (Down)= 252.702-kN Tip Resistance (Up)= 0.000-kN
Total Ultimate Capacity (Down)= 772.411-kN Total Ultimate Capacity (Up)= 550.348-kN
Total Allowable Capacity (Down)= 472.823-kN Total Allowable Capacity (Up)= 301.738-kN
OK! Qallow > Q

Settlement Calculation:
At Q= 472.00-kN Settlement= 0.09712-cm
At Xallow= 2.50-cm Qallow= 733.38062-kN

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-14m
*****************************************************************
ALLPILE 6
VERTICAL ANALYSIS SUMMARY OUTPUT
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\Ø500mm-14m long

Title 1: Genex Investment


Title 2: Foundation Pile Ø500mm-14m

TOTAL LOADS:
Vertical Load, Q: 472.0 -kN
Load Factor for Vertical Loads: 1.0
Loads Supported by Pile Cap: 0 %

PILE PROFILE:
Pile Length, L= 14.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0.00 Batter Factor, Kbat= 1.00

SINGLE PILE:
Deduction factor due to Group Effect, R= 1.00
Vertical Load= 472.00 -kN

Single Pile Vertical Analysis:


Results:
Total Ultimate Capacity (Down)= 772.41-kN, Total Ultimate Capacity (Up)= 550.35-kN
Total Allowable Capacity (Down)= 472.82-kN, Total Allowable Capacity (Up)= 301.74-kN
At Work Load= 472.00-kN, Settlement= 0.09712-cm
At Work Load= 472.00-kN, Secant Stiffness Kqx= 4860.19-kN/-cm
At Allowable Settlement= 2.500-cm, Capacity= 733.38-kN
Work Load, 472.00-kN, OK with the Capacity at Allowable Settlement= 2.50-cm, Capacity= 733.38-kN
Work Load, 472.00-kN, OK with the Allowable Capacity (Down)= 472.82-kN

____________________________________________
FACTOR OF SAFETY:
FSside FStip FSuplif FSweight
2.5 2 3 1

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

Concrete poured into drilled hole.


Diameter is limited to 24in (61cm).

FOUNDATION PROFILE & SOIL CONDITIONS

Depth FOUNDATION PROPERTIES SOIL PROPERTIES Depth


from from
Ground-m Ground-m
Depth Width-cm A'-cm2 Per.-cm I'-cm4 E -MP W -kN/m Depth  -kN/m3  C-kN/m2 k-MN/m3 e50 % Nspt
0 0
0.0 50 3062.7 157.1 320535.8 25000 5.719 0.0 10.9 31.9 47.9 164.2 0.66 16
Concrete (rough) Silt (Phi + C)

1 1

1.5 12.2 26.4 150.8 672.0 0.33 50


2 Silt (Phi + C) 2

3 3
3.0 10.6 27.2 32.6 96.3 0.83 11
Silt (Phi + C)

4 4

4.5 9.8 0.0 41.9 48.7 1.08 7


5 Stiff Clay 5

6 6

7 7

8 8

9 9

10 10

11 11

12 12

13 13
13.0 50 3062.7 157.1 320535.8 25000 5.719
Concrete (rough)

14 14
14.0 50 1963.5 157.1 320535.8 25000 5.719 14.0 11.2 0.0 143.0 278.5 0.51 24
Pile Tip Stiff Clay

15 15

Batter Angle=0 (Pile diameter not to scale) Surface Angle=0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-14m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

Vertical Load vs. Settlement

800

720

640
Compression Load, Qdw -kN

560

480

400

320

240

160

80

0
0.0 0.3 0.5 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 2.8 3.0 3.3 3.5 3.8 4.0 4.3 4.5 4.8 5.0

Settlement, X -cm
Total Side Tip

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-14m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

ALLOWABLE CAPACITY vs FOUNDATION DEPTH

500 500

450 450

400 400
Compression Capacity, Qdw -kN

350 350

Uplift Capacity, Qup -kN


300 300

250 250

200 200

150 150

100 100

50 50

0 0
0 2 4 6 8 10 12 14 16 18 20 0 2 4 6 8 10 12 14 16 18 20
Foundation Depth, L -m Foundation Depth, L -m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-14m
LATERAL CAPACITY CALCULATION Ø500mm-14m
LONG USING BH-1
LATERAL ANALYSIS Figure 2

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

Vertical Load, Q= 472.0 -kN


Shear Load, P= 290.0 -kN
Slope Restain St= 0.00 -cm/-cm

Profile:
Pile Length, L= 14.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0

Fixed Head Condition

Drilled Pile (dia <=24 in. or 61 cm)

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MP -kN/m
0 10.9 31.9 47.9 164.2 0.66 16 0.0 50 3062.7 157.1 320535.8 25000 5.719
1.5 12.2 26.4 150.8 672.0 0.33 50 13.0 50 3062.7 157.1 320535.8 25000 5.719
3.0 10.6 27.2 32.6 96.3 0.83 11 14.0 50 1963.5 157.1 320535.8 25000 5.719
4.5 9.8 0.0 41.9 48.7 1.08 7
14 11.2 0.0 143.0 278.5 0.51 24
Single Pile Lateral Analysis:
Top Deflection, yt= 2.44000-cm
Max. Moment, M= 544.00-kN-m
Top Deflection Slope, St= 0.00000
OK! Top Deflection, 2.4400-cm is less than the Allowable Deflection= 2.50-cm

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
The Max. Moment calculated by program is an internal force from the applied load conditions. Structural engineer has to check whether
the pile has enough capacity to resist the moment with adequate factor of safety. If not, the pile may fail under the load conditions.

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-14m
*****************************************************************
ALLPILE 6
LATERAL ANALYSIS SUMMARY OUTPUT
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\
Ø500mm-14m long.alp
Title 1: Genex Investment
Title 2: Foundation Pile Ø500mm-14m

PILE PROFILES:
Pile Length, L= 14.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0.00

FACTORS AND CONDITIONS:


Load Factor for Vertical Loads: 1.0
Load Factor for Lateral Loads: 1.0
Loads Supported by Pile Cap: 0 %
Shear Condition: Static

SINGLE PILE:
Deduction factor due to Group Effect, R= 1.00
Vertical Load= 472.00 -kN
Shear= 290.00 -kN
Slope Restain, St= 0.00 -cm/-cm

Results:
Top Deflection, yt= 2.44000-cm
Max. Moment, M= 544.00-kN-m
Top Deflection Slope, St= 0.00000

Top Deflection, 2.4400-cm, OK with the Allowable Deflection= 2.50-cm


Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
____________________________________

Notes:
Q - Vertical Load at pile top
P - Lateral Shear Load at pile top
M - Moment at pile top
Xall - Pile top total settlement
yt - Pile top deflection
St - Pile top deflection slope (deflection/unit length)
The Max. Moment calculated by program is an internal moment of shaft due to the loading. Egineers
have to check whether the pile has enough moment capacity to resist the Max. Moment with adequate
factor of safety. If not, the pile may be damaged under the loading.
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE DEFLECTION & FORCE vs DEPTH


Single Pile, Khead=5, Kbc=2

Depth (Zp) DEFLECTION, yt -cm MOMENT -kN-m SHEAR -kN Pressure -kN/m2 Depth (Zp)
from from
Pile Top-m -5.00 0 +5.00 -1000 0 +1000 -500 0 +500 -100 0 +100 Pile Top-m
0 0

1 1

2 2

3 3

4 4

5 5
yt=0 at 5.6-m
6 6

St=0 at 6.7-m
7 7

8 8

9 9

10 10

11 11

12 12

13 13

14 14
Tip yt=-2.23E-5 Top yt=2.44E+0 Top Moment=-544.0 Top Shear=290.0
Max. yt=2.44E+0 Max. Moment=544.0 Max. Shear=292.9 Max. Pressure=52.50
Top St=-1.23E-17
15 15

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-14m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE DEFLECTION vs LOADING


Single Pile, Khead=5, Kbc=2

Depth (Zp) DEFLECTION, yt -cm Depth (Zp)


from from
Pile Top-m -5.00 0 +5.00 Pile Top-m
0 0

1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

9 9

10 10

11 11

12 12
Lateral Slope Vertical yt Slope Max.
No. Load Restraint Load at Top at Top Moment
13 (kN) (cm/cm) (kN) (cm) (cm/cm) (kN-m) 13
1 29.0 0.0 472.0 0.1 0.00 32.1
2 87.0 0.0 472.0 0.4 0.00 129.0
14 3 145.0 0.0 472.0 0.9 0.00 241.0 14
4 203.0 0.0 472.0 1.5 0.00 359.0
5 232.0 0.0 472.0 1.8 0.00 418.0
15 6 261.0 0.0 472.0 2.1 0.00 479.0 15
7 290.0 0.0 472.0 2.4 0.00 544.0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-14m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE MOMENT vs LOADING


Single Pile, Khead=5, Kbc=2

Depth (Zp) MOMENT -kN-m Depth (Zp)


from from
Pile Top-m -1000.00 0 +1000.00 Pile Top-m
0 0

1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

9 9

10 10

11 11

12 12
Lateral Slope Vertical yt Slope Max.
No. Load Restraint Load at Top at Top Moment
13 (kN) (cm/cm) (kN) (cm) (cm/cm) (kN-m) 13
1 29.0 0.0 472.0 0.1 0.00 32.1
2 87.0 0.0 472.0 0.4 0.00 129.0
14 3 145.0 0.0 472.0 0.9 0.00 241.0 14
4 203.0 0.0 472.0 1.5 0.00 359.0
5 232.0 0.0 472.0 1.8 0.00 418.0
15 6 261.0 0.0 472.0 2.1 0.00 479.0 15
7 290.0 0.0 472.0 2.4 0.00 544.0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-14m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

LATERAL LOAD vs DEFLECTION & MAX. MOMENT

300 300

270 270

240 240

210 210

180 180
Lateral Load, P -kN

Lateral Load, P -kN


150 150

120 120

90 90

60 60

30 30

0 0
0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 0 60 120 180 240 300 360 420 480 540 600
Top Deflection, yt -cm Max. Moment in Single Pile, Mmax -kN-m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-14m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

P-Y curves for soils

300

270

240

210
p, -kN/m

180

150

120

90

60

30

0
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

y, -m
Depth: 1.8, 3.5, 5.3, 7.0, 8.8, 10.5, 12.3 -m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-14m
PILE STIFFNESS CALCULATION SHEET Ø500mm-14m LONG
USING BH-1 DATA
*****************************************************************
ALLPILE 6
PILE STIFFNESS ANALYSIS SUMMARY
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\
Ø500mm-14m long.alp
Title 1: Genex Investment
Title 2: Foundation Pile Ø500mm-14m

ingle Pile Vertical Analysis:


Q= 472.00 -kN
Results:
At Work Load= 472.00-kN, Settlement, Xall= 0.14873-cm
Stiffness Kqx= 3173.60-kN/-cm

Single Pile Lateral Analysis - Free Head:

M= 0, P= 290.00 -kN
Results:
At Shear= 290.00-kN, Top Deflection, yt= 12.30000-cm
Stiffness Kpy= 23.58-kN/-cm
At Shear= 290.00-kN, Top Slope, St= -0.03690 Slope
Stiffness Kps= -7859.08-kN/Slope
Or St= -2.11325550 Degree, Stiffness Kps= -137.23-kN/Degree
P= 0, M= 10.00 -kN-m
Results:
At Moment= 10.00-kN, Top Deflection, yt= 0.01690-cm
Stiffness Kmy= 591.72-kN-m/-cm
At Moment= 10.00-kN, Top Slope, St= -0.00020 Slope
Stiffness Kms= -49019.61-kN-m/Slope
Or St= -0.01168834 Degree, Stiffness Kms= -855.55-kN-m/Degree

Single Pile Lateral Analysis - Fixed Head:

M= 0, P= 290.00 -kN
Results:
At Shear= 290.00-kN, Top Deflection, yt= 2.44000-cm
Stiffness Kpy= 118.85-kN/-cm
At Shear= 290.00-kN, Top Slope, St= 0.00000
Stiffness Kps= N/A
P= 0, M= 10.00 -kN-m
Results:
At Moment= 10.00-kN, Top Deflection, yt= 0.00000-cm
Stiffness Kmy= N/A
At Moment= 10.00-kN, Top Slope, St= 0.00000
Stiffness Kms= N/A
Notes:
Q - Vertical Load at pile top
P - Lateral Shear Load at pile top
M - Moment at pile top
Xall - Pile top total settlement
yt - Pile top deflection
St - Pile top deflection slope (deflection/unit length). Clockwise is negative
Kqx - Secant Stiffness: Vertical load vs. Vertical movement (settlement)
Kpy - Secant Stiffness: Lateral Shear vs. Lateral movement (deflection)
Kps - Secant Stiffness: Lateral Shear vs. Slope (rotation). Clockwise is negative
Kmy - Secant Stiffness: Moment vs. Lateral movement (deflection)
Kms - Secant Stiffness: Moment vs. Slope (rotation). Clockwise is negative

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
ETABS 18.1.1 License #*1VHQUC7UK2NRLHB

ETABS Concrete Frame Design


IS 456:2000 + IS 13920:2016 Column Section Design

RCC verification of 600mm Dia Pile-12m length-BH3

Column Element Details Type: Ductile Frame (Summary)


Level Element Unique Name Section ID Combo ID Station Loc Length (mm) LLRF
-0m C1 13 Ø600-6-Ø20+6-Ø25-Ø10-175 DL+LL 0 1500 1

Section Properties
d (mm) h0 (mm) dc (mm) Cover (Torsion) (mm)
600 503.7 96.3 65

Material Properties
Ec (MPa) fck (MPa) Lt.Wt Factor (Unitless) fy (MPa) fys (MPa)
25000 25 1 500 500

Design Code Parameters


ɣC ɣS
1.5 1.15

Axial Force and Biaxial Moment Design For Pu , Mu2 , Mu3


Design Pu Design Mu2 Design Mu3 Minimum M2 Minimum M3 Rebar % Capacity Ratio
kN kN-m kN-m kN-m kN-m % Unitless
1009.3196 23.2144 377.1351 23.2144 23.2144 1.72 0.95

Axial Force and Biaxial Moment Factors


K Factor Length Initial Moment Additional Moment Minimum Moment
Unitless mm kN-m kN-m kN-m
Major Bend(M3) 1.2 1500 226.281 0 23.2144
Minor Bend(M2) 1.2 1500 0 0 23.2144

Shear Design for Vu2 , Vu3


Shear Vu Shear Vc Shear Vs Shear Vp Rebar Asv /s
kN kN kN kN mm²/m
Major, Vu2 251.4234 226.7712 101.3627 0 665.06
Minor, Vu3 0 226.7712 101.3627 0 665.06

Joint Shear Check/Design

Revised Pile verification 600Dia-12m-BH3.EDB Page 1 of 2 5/1/2022


ETABS 18.1.1 License #*1VHQUC7UK2NRLHB

Joint Shear Shear Shear Shear Joint Shear


Force VTop Vu,Tot Vc Area Ratio
kN kN kN kN cm² Unitless
Major Shear, Vu2 N/A N/A N/A N/A N/A N/A
Minor Shear, Vu3 N/A N/A N/A N/A N/A N/A

(1.4) Beam/Column Capacity Ratio


Major Ratio Minor Ratio
N/A N/A

Additional Moment Reduction Factor k (IS 39.7.1.1)


Ag Asc Puz Pb Pu k
cm² cm² kN kN kN Unitless
2827.4 48.2 4969.4632 1295.4097 1009.3196 1

Additional Moment (IS 39.7.1)


Consider Length Section KL/Depth KL/Depth KL/Depth Ma
Ma Factor Depth (mm) Ratio Limit Exceeded Moment (kN-m)
Major Bending (M3 ) Yes 1 600 3 12 No 0
Minor Bending (M2 ) Yes 1 600 3 12 No 0

Notes:

N/A: Not Applicable

N/C: Not Calculated

N/N: Not Needed

Revised Pile verification 600Dia-12m-BH3.EDB Page 2 of 2 5/1/2022


VERTICAL CAPACITY PILE CALCULATION Ø500mm-16m LONG
USING BH-1 DATA
VERTICAL ANALYSIS Figure 1

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

Vertical Load, Q= 508.0 -kN


Shear Load, P= 0.0 -kN
Slope Restain St= 0.00 -cm/-cm

Profile:
Pile Length, L= 16.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0

Fixed Head Condition

Drilled Pile (dia <=24 in. or 61 cm)

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MP -kN/m
0 10.9 31.9 47.9 164.2 0.66 16 0.0 50 3062.7 157.1 320535.8 25000 5.719
1.5 12.2 26.4 150.8 672.0 0.33 50 15.0 50 3062.7 157.1 320535.8 25000 5.719
3.0 10.6 27.2 32.6 96.3 0.83 11 16.0 50 1963.5 157.1 320535.8 25000 5.719
4.5 9.8 0.0 41.9 48.7 1.08 7
16 11.2 0.0 143.0 278.5 0.51 24

Vertical capacity:
Weight above Ground= 0.00 Total Weight= 60.72-kN *Soil Weight is not included
Side Resistance (Down)= 573.874-kN Side Resistance (Up)= 551.336-kN
Tip Resistance (Down)= 252.702-kN Tip Resistance (Up)= 0.000-kN
Total Ultimate Capacity (Down)= 826.577-kN Total Ultimate Capacity (Up)= 612.053-kN
Total Allowable Capacity (Down)= 508.934-kN Total Allowable Capacity (Up)= 336.385-kN
OK! Qallow > Q

Settlement Calculation:
At Q= 508.00-kN Settlement= 0.10006-cm
At Xallow= 2.50-cm Qallow= 779.01764-kN

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-16m
*****************************************************************
ALLPILE 6
VERTICAL ANALYSIS SUMMARY OUTPUT
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\Ø500mm-16m long

Title 1: Genex Investment


Title 2: Foundation Pile Ø500mm-16m

TOTAL LOADS:
Vertical Load, Q: 508.0 -kN
Load Factor for Vertical Loads: 1.0
Loads Supported by Pile Cap: 0 %

PILE PROFILE:
Pile Length, L= 16.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0.00 Batter Factor, Kbat= 1.00

SINGLE PILE:
Deduction factor due to Group Effect, R= 1.00
Vertical Load= 508.00 -kN

Single Pile Vertical Analysis:


Results:
Total Ultimate Capacity (Down)= 826.58-kN, Total Ultimate Capacity (Up)= 612.05-kN
Total Allowable Capacity (Down)= 508.93-kN, Total Allowable Capacity (Up)= 336.38-kN
At Work Load= 508.00-kN, Settlement= 0.10006-cm
At Work Load= 508.00-kN, Secant Stiffness Kqx= 5076.81-kN/-cm
At Allowable Settlement= 2.500-cm, Capacity= 779.02-kN
Work Load, 508.00-kN, OK with the Capacity at Allowable Settlement= 2.50-cm, Capacity= 779.02-kN
Work Load, 508.00-kN, OK with the Allowable Capacity (Down)= 508.93-kN

____________________________________________
FACTOR OF SAFETY:
FSside FStip FSuplif FSweight
2.5 2 3 1

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

Concrete poured into drilled hole.


Diameter is limited to 24in (61cm).

FOUNDATION PROFILE & SOIL CONDITIONS

Depth FOUNDATION PROPERTIES SOIL PROPERTIES Depth


from from
Ground-m Ground-m
Depth Width-cm A'-cm2 Per.-cm I'-cm4 E -MP W -kN/m Depth  -kN/m3  C-kN/m2 k-MN/m3 e50 % Nspt
0 0
0.0 50 3062.7 157.1 320535.8 25000 5.719 0.0 10.9 31.9 47.9 164.2 0.66 16
Concrete (rough) Silt (Phi + C)

2 1.5 12.2 26.4 150.8 672.0 0.33 50 2


Silt (Phi + C)

3.0 10.6 27.2 32.6 96.3 0.83 11


4 Silt (Phi + C) 4
4.5 9.8 0.0 41.9 48.7 1.08 7
Stiff Clay
6 6

8 8

10 10

12 12

14 14

15.0 50 3062.7 157.1 320535.8 25000 5.719


16 Concrete (rough) 16
16.0 11.2 0.0 143.0 278.5 0.51 24
16.0 50 1963.5 157.1 320535.8 25000 5.719 Stiff Clay
Pile Tip
18 18

20 20

22 22

24 24

26 26

28 28

30 30

Batter Angle=0 (Pile diameter not to scale) Surface Angle=0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-16m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

Vertical Load vs. Settlement

900

810

720
Compression Load, Qdw -kN

630

540

450

360

270

180

90

0
0.0 0.3 0.5 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 2.8 3.0 3.3 3.5 3.8 4.0 4.3 4.5 4.8 5.0

Settlement, X -cm
Total Side Tip

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-16m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

ALLOWABLE CAPACITY vs FOUNDATION DEPTH

600 600

540 540

480 480
Compression Capacity, Qdw -kN

420 420

Uplift Capacity, Qup -kN


360 360

300 300

240 240

180 180

120 120

60 60

0 0
0 2 4 6 8 10 12 14 16 18 20 0 2 4 6 8 10 12 14 16 18 20
Foundation Depth, L -m Foundation Depth, L -m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-16m
LATERAL CAPACITY CALCULATION Ø500mm-16m
LONG USING BH-1
LATERAL ANALYSIS Figure 2

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

Vertical Load, Q= 508.0 -kN


Shear Load, P= 295.0 -kN
Slope Restain St= 0.00 -cm/-cm

Profile:
Pile Length, L= 16.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0

Fixed Head Condition

Drilled Pile (dia <=24 in. or 61 cm)

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MP -kN/m
0 10.9 31.9 47.9 164.2 0.66 16 0.0 50 3062.7 157.1 320535.8 25000 5.719
1.5 12.2 26.4 150.8 672.0 0.33 50 15.0 50 3062.7 157.1 320535.8 25000 5.719
3.0 10.6 27.2 32.6 96.3 0.83 11 16.0 50 1963.5 157.1 320535.8 25000 5.719
4.5 9.8 0.0 41.9 48.7 1.08 7
16 11.2 0.0 143.0 278.5 0.51 24
Single Pile Lateral Analysis:
Top Deflection, yt= 2.49000-cm
Max. Moment, M= 554.00-kN-m
Top Deflection Slope, St= 0.00000
OK! Top Deflection, 2.4900-cm is less than the Allowable Deflection= 2.50-cm

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
The Max. Moment calculated by program is an internal force from the applied load conditions. Structural engineer has to check whether
the pile has enough capacity to resist the moment with adequate factor of safety. If not, the pile may fail under the load conditions.

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-16m
*****************************************************************
ALLPILE 6
LATERAL ANALYSIS SUMMARY OUTPUT
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\
Ø500mm-16m long.alp
Title 1: Genex Investment
Title 2: Foundation Pile Ø500mm-16m

PILE PROFILES:
Pile Length, L= 16.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0.00

FACTORS AND CONDITIONS:


Load Factor for Vertical Loads: 1.0
Load Factor for Lateral Loads: 1.0
Loads Supported by Pile Cap: 0 %
Shear Condition: Static

SINGLE PILE:
Deduction factor due to Group Effect, R= 1.00
Vertical Load= 508.00 -kN
Shear= 295.00 -kN
Slope Restain, St= 0.00 -cm/-cm

Results:
Top Deflection, yt= 2.49000-cm
Max. Moment, M= 554.00-kN-m
Top Deflection Slope, St= 0.00000

Top Deflection, 2.4900-cm, OK with the Allowable Deflection= 2.50-cm


Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
____________________________________

Notes:
Q - Vertical Load at pile top
P - Lateral Shear Load at pile top
M - Moment at pile top
Xall - Pile top total settlement
yt - Pile top deflection
St - Pile top deflection slope (deflection/unit length)
The Max. Moment calculated by program is an internal moment of shaft due to the loading. Egineers
have to check whether the pile has enough moment capacity to resist the Max. Moment with adequate
factor of safety. If not, the pile may be damaged under the loading.
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE DEFLECTION & FORCE vs DEPTH


Single Pile, Khead=5, Kbc=2

Depth (Zp) DEFLECTION, yt -cm MOMENT -kN-m SHEAR -kN Pressure -kN/m2 Depth (Zp)
from from
Pile Top-m -5.00 0 +5.00 -1000 0 +1000 -500 0 +500 -100 0 +100 Pile Top-m
0 0

2 2

4 4

yt=0 at 5.6-m
6 6
St=0 at 6.7-m

8 8

10 10

12 12

14 14

16 16
Tip yt=3.8E-6 Top yt=2.49E+0 Top Moment=-554.0 Top Shear=295.0
Max. yt=2.49E+0 Max. Moment=554.0 Max. Shear=300.0 Max. Pressure=53.00
Top St=2.15E-17
18 18

20 20

22 22

24 24

26 26

28 28

30 30

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-16m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE DEFLECTION vs LOADING


Single Pile, Khead=5, Kbc=2

Depth (Zp) DEFLECTION, yt -cm Depth (Zp)


from from
Pile Top-m -5.00 0 +5.00 Pile Top-m
0 0

2 2

4 4

6 6

8 8

10 10

12 12

14 14

16 16

18 18

20 20

22 22

24 24
Lateral Slope Vertical yt Slope Max.
No. Load Restraint Load at Top at Top Moment
26 (kN) (cm/cm) (kN) (cm) (cm/cm) (kN-m) 26
1 29.5 0.0 508.0 0.1 0.00 32.7
2 88.5 0.0 508.0 0.4 0.00 131.0
28 3 148.0 0.0 508.0 0.9 0.00 245.0 28
4 206.0 0.0 508.0 1.5 0.00 365.0
5 236.0 0.0 508.0 1.8 0.00 425.0
30 6 266.0 0.0 508.0 2.1 0.00 487.0 30
7 295.0 0.0 508.0 2.5 0.00 554.0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-16m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE MOMENT vs LOADING


Single Pile, Khead=5, Kbc=2

Depth (Zp) MOMENT -kN-m Depth (Zp)


from from
Pile Top-m -1000.00 0 +1000.00 Pile Top-m
0 0

2 2

4 4

6 6

8 8

10 10

12 12

14 14

16 16

18 18

20 20

22 22

24 24
Lateral Slope Vertical yt Slope Max.
No. Load Restraint Load at Top at Top Moment
26 (kN) (cm/cm) (kN) (cm) (cm/cm) (kN-m) 26
1 29.5 0.0 508.0 0.1 0.00 32.7
2 88.5 0.0 508.0 0.4 0.00 131.0
28 3 148.0 0.0 508.0 0.9 0.00 245.0 28
4 206.0 0.0 508.0 1.5 0.00 365.0
5 236.0 0.0 508.0 1.8 0.00 425.0
30 6 266.0 0.0 508.0 2.1 0.00 487.0 30
7 295.0 0.0 508.0 2.5 0.00 554.0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-16m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

LATERAL LOAD vs DEFLECTION & MAX. MOMENT

300 300

270 270

240 240

210 210

180 180
Lateral Load, P -kN

Lateral Load, P -kN


150 150

120 120

90 90

60 60

30 30

0 0
0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 0 60 120 180 240 300 360 420 480 540 600
Top Deflection, yt -cm Max. Moment in Single Pile, Mmax -kN-m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-16m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

P-Y curves for soils

300

270

240

210
p, -kN/m

180

150

120

90

60

30

0
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

y, -m
Depth: 2.0, 4.0, 6.0, 8.0, 10.0, 12.0, 14.0 -m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø500mm-16m
PILE STIFFNESS CALCULATION SHEET Ø500mm-16m LONG
USING BH-1 DATA
*****************************************************************
ALLPILE 6
PILE STIFFNESS ANALYSIS SUMMARY
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\
Ø500mm-16m long.alp
Title 1: Genex Investment
Title 2: Foundation Pile Ø500mm-16m

Single Pile Vertical Analysis:


Q= 508.00 -kN
Results:
At Work Load= 508.00-kN, Settlement, Xall= 0.14816-cm
Stiffness Kqx= 3428.81-kN/-cm

Single Pile Lateral Analysis - Free Head:

M= 0, P= 295.00 -kN
Results:
At Shear= 295.00-kN, Top Deflection, yt= 12.70000-cm
Stiffness Kpy= 23.23-kN/-cm
At Shear= 295.00-kN, Top Slope, St= -0.03810 Slope
Stiffness Kps= -7742.78-kN/Slope
Or St= -2.18191385 Degree, Stiffness Kps= -135.20-kN/Degree
P= 0, M= 10.00 -kN-m
Results:
At Moment= 10.00-kN, Top Deflection, yt= 0.01700-cm
Stiffness Kmy= 588.24-kN-m/-cm
At Moment= 10.00-kN, Top Slope, St= -0.00021 Slope
Stiffness Kms= -48780.49-kN-m/Slope
Or St= -0.01174563 Degree, Stiffness Kms= -851.38-kN-m/Degree

Single Pile Lateral Analysis - Fixed Head:

M= 0, P= 295.00 -kN
Results:
At Shear= 295.00-kN, Top Deflection, yt= 2.49000-cm
Stiffness Kpy= 118.47-kN/-cm
At Shear= 295.00-kN, Top Slope, St= 0.00000
Stiffness Kps= N/A
P= 0, M= 10.00 -kN-m
Results:
At Moment= 10.00-kN, Top Deflection, yt= 0.00000-cm
Stiffness Kmy= N/A
At Moment= 10.00-kN, Top Slope, St= 0.00000
Stiffness Kms= N/A
Notes:
Q - Vertical Load at pile top
P - Lateral Shear Load at pile top
M - Moment at pile top
Xall - Pile top total settlement
yt - Pile top deflection
St - Pile top deflection slope (deflection/unit length). Clockwise is negative
Kqx - Secant Stiffness: Vertical load vs. Vertical movement (settlement)
Kpy - Secant Stiffness: Lateral Shear vs. Lateral movement (deflection)
Kps - Secant Stiffness: Lateral Shear vs. Slope (rotation). Clockwise is negative
Kmy - Secant Stiffness: Moment vs. Lateral movement (deflection)
Kms - Secant Stiffness: Moment vs. Slope (rotation). Clockwise is negative

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
VERTICAL CAPACITY PILE CALCULATION Ø600mm-12m LONG
USING BH-1 DATA
VERTICAL ANALYSIS Figure 1

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

Vertical Load, Q= 570.0 -kN


Shear Load, P= 0.0 -kN
Slope Restain St= 0.00 -cm/-cm

Profile:
Pile Length, L= 12.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0

Fixed Head Condition

Drilled Pile (dia <=24 in. or 61 cm)

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MP -kN/m
0 11.6 30.2 92.8 386.4 0.44 31 0.0 60 4410.2 188.5 664662.9 25000 8.236
1.5 11.2 30.2 74.8 295.0 0.50 25 11.0 60 4410.2 188.5 664662.9 25000 8.236
3.0 10.4 29.5 27.5 75.1 0.92 9 12.0 60 2827.4 188.5 664662.9 25000 7.069
4.5 10.5 0.0 61.0 87.5 0.86 10
12 11.0 0.0 120.3 222.4 0.57 20

Vertical capacity:
Weight above Ground= 0.00 Total Weight= 65.58-kN *Soil Weight is not included
Side Resistance (Down)= 628.824-kN Side Resistance (Up)= 601.682-kN
Tip Resistance (Down)= 306.123-kN Tip Resistance (Up)= 0.000-kN
Total Ultimate Capacity (Down)= 934.946-kN Total Ultimate Capacity (Up)= 667.264-kN
Total Allowable Capacity (Down)= 572.277-kN Total Allowable Capacity (Up)= 366.423-kN
OK! Qallow > Q

Settlement Calculation:
At Q= 570.00-kN Settlement= 0.11067-cm
At Xallow= 2.50-cm Qallow= 909.28967-kN

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-12m
*****************************************************************
ALLPILE 6
VERTICAL ANALYSIS SUMMARY OUTPUT
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\Ø600mm-12m long

Title 1: Genex Investment


Title 2: Foundation Pile Ø600mm-12m

OTAL LOADS:
Vertical Load, Q: 570.0 -kN
Load Factor for Vertical Loads: 1.0
Loads Supported by Pile Cap: 0 %

PILE PROFILE:
Pile Length, L= 12.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0.00 Batter Factor, Kbat= 1.00

SINGLE PILE:
Deduction factor due to Group Effect, R= 1.00
Vertical Load= 570.00 -kN

Single Pile Vertical Analysis:


Results:
Total Ultimate Capacity (Down)= 934.95-kN, Total Ultimate Capacity (Up)= 667.26-kN
Total Allowable Capacity (Down)= 572.28-kN, Total Allowable Capacity (Up)= 366.42-kN
At Work Load= 570.00-kN, Settlement= 0.11067-cm
At Work Load= 570.00-kN, Secant Stiffness Kqx= 5150.35-kN/-cm
At Allowable Settlement= 2.500-cm, Capacity= 909.29-kN
Work Load, 570.00-kN, OK with the Capacity at Allowable Settlement= 2.50-cm, Capacity= 909.29-kN
Work Load, 570.00-kN, OK with the Allowable Capacity (Down)= 572.28-kN

____________________________________________
FACTOR OF SAFETY:
FSside FStip FSuplif FSweight
2.5 2 3 1

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

Concrete poured into drilled hole.


Diameter is limited to 24in (61cm).

FOUNDATION PROFILE & SOIL CONDITIONS

Depth FOUNDATION PROPERTIES SOIL PROPERTIES Depth


from from
Ground-m Ground-m
Depth Width-cm A'-cm2 Per.-cm I'-cm4 E -MP W -kN/m Depth  -kN/m3  C-kN/m2 k-MN/m3 e50 % Nspt
0 0
0.0 60 4410.2 188.5 664662.9 25000 8.236 0.0 11.6 30.2 92.8 386.4 0.44 31
Concrete (rough) Silt (Phi + C)

1 1

1.5 11.2 34.2 74.8 295.0 0.50 25


2 Silt (Phi + C) 2

3 3
3.0 10.4 29.5 27.5 75.1 0.92 9
Silt (Phi + C)

4 4

4.5 10.5 0.0 61.0 87.5 0.86 10


5 Stiff Clay 5

6 6

7 7

8 8

9 9

10 10

11 11
11.0 60 4410.2 188.5 664662.9 25000 8.236
Concrete (rough)

12 12
12.0 60 2827.4 188.5 664662.9 25000 7.069 12.0 11.0 0.0 120.3 222.4 0.57 20
Pile Tip Stiff Clay

13 13

14 14

15 15

Batter Angle=0 (Pile diameter not to scale) Surface Angle=0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-12m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

Vertical Load vs. Settlement

1000

900

800
Compression Load, Qdw -kN

700

600

500

400

300

200

100

0
0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 5.7 6.0

Settlement, X -cm
Total Side Tip

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-12m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

ALLOWABLE CAPACITY vs FOUNDATION DEPTH

600 600

540 540

480 480
Compression Capacity, Qdw -kN

420 420

Uplift Capacity, Qup -kN


360 360

300 300

240 240

180 180

120 120

60 60

0 0
0 2 4 6 8 10 12 14 16 18 20 0 2 4 6 8 10 12 14 16 18 20
Foundation Depth, L -m Foundation Depth, L -m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-12m
LATERAL CAPACITY CALCULATION Ø600mm-12m
LONG USING BH-1
LATERAL ANALYSIS Figure 2

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

Vertical Load, Q= 555.0 -kN


Shear Load, P= 405.0 -kN
Slope Restain St= 0.00 -cm/-cm

Profile:
Pile Length, L= 12.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0

Fixed Head Condition

Drilled Pile (dia <=24 in. or 61 cm)

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MP -kN/m
0 10.9 31.9 47.9 164.2 0.66 16 0.0 60 4410.2 188.5 664662.9 25000 8.236
1.5 12.2 26.4 150.8 672.0 0.33 50 11.0 60 4410.2 188.5 664662.9 25000 8.236
3.0 10.6 27.2 32.6 96.3 0.83 11 12.0 60 2827.4 188.5 664662.9 25000 7.069
4.5 9.8 0.0 41.9 48.7 1.08 7
12 11.2 0.0 143.0 278.5 0.51 24
Single Pile Lateral Analysis:
Top Deflection, yt= 2.45000-cm
Max. Moment, M= 860.00-kN-m
Top Deflection Slope, St= 0.00000
OK! Top Deflection, 2.4500-cm is less than the Allowable Deflection= 2.50-cm

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
The Max. Moment calculated by program is an internal force from the applied load conditions. Structural engineer has to check whether
the pile has enough capacity to resist the moment with adequate factor of safety. If not, the pile may fail under the load conditions.

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-12m
*****************************************************************
ALLPILE 6
LATERAL ANALYSIS SUMMARY OUTPUT
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\
Ø600mm-12m long.alp
Title 1: Genex Investment
Title 2: Foundation Pile Ø600mm-12m

ILE PROFILES:
Pile Length, L= 12.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0.00

FACTORS AND CONDITIONS:


Load Factor for Vertical Loads: 1.0
Load Factor for Lateral Loads: 1.0
Loads Supported by Pile Cap: 0 %
Shear Condition: Static

SINGLE PILE:
Deduction factor due to Group Effect, R= 1.00
Vertical Load= 555.00 -kN
Shear= 405.00 -kN
Slope Restain, St= 0.00 -cm/-cm

Results:
Top Deflection, yt= 2.45000-cm
Max. Moment, M= 860.00-kN-m
Top Deflection Slope, St= 0.00000

Top Deflection, 2.4500-cm, OK with the Allowable Deflection= 2.50-cm


Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
____________________________________

Notes:
Q - Vertical Load at pile top
P - Lateral Shear Load at pile top
M - Moment at pile top
Xall - Pile top total settlement
yt - Pile top deflection
St - Pile top deflection slope (deflection/unit length)
The Max. Moment calculated by program is an internal moment of shaft due to the loading. Egineers
have to check whether the pile has enough moment capacity to resist the Max. Moment with adequate
factor of safety. If not, the pile may be damaged under the loading.
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE DEFLECTION & FORCE vs DEPTH


Single Pile, Khead=5, Kbc=2

Depth (Zp) DEFLECTION, yt -cm MOMENT -kN-m SHEAR -kN Pressure -kN/m2 Depth (Zp)
from from
Pile Top-m -5.00 0 +5.00 -1000 0 +1000 -500 0 +500 -100 0 +100 Pile Top-m
0 0

1 1

2 2

3 3

4 4

5 5

6 6
yt=0 at 6.4-m
St=0 at 0.1-m
7 7

8 8

9 9

10 10

11 11

12 12
Tip yt=7.32E-3 Top yt=2.45E+0 Top Moment=-860.0 Top Shear=405.0
Max. yt=2.45E+0 Max. Moment=860.0 Max. Shear=408.3 Max. Pressure=52.08
Top St=1.43E-17
13 13

14 14

15 15

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-12m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE DEFLECTION vs LOADING


Single Pile, Khead=5, Kbc=2

Depth (Zp) DEFLECTION, yt -cm Depth (Zp)


from from
Pile Top-m -5.00 0 +5.00 Pile Top-m
0 0

1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

9 9

10 10

11 11

12 12
Lateral Slope Vertical yt Slope Max.
No. Load Restraint Load at Top at Top Moment
13 (kN) (cm/cm) (kN) (cm) (cm/cm) (kN-m) 13
1 40.5 0.0 555.0 0.1 0.00 49.9
2 122.0 0.0 555.0 0.4 0.00 203.0
14 3 202.0 0.0 555.0 0.9 0.00 380.0 14
4 284.0 0.0 555.0 1.5 0.00 569.0
5 324.0 0.0 555.0 1.8 0.00 665.0
15 6 364.0 0.0 555.0 2.1 0.00 762.0 15
7 405.0 0.0 555.0 2.5 0.00 860.0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-12m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE MOMENT vs LOADING


Single Pile, Khead=5, Kbc=2

Depth (Zp) MOMENT -kN-m Depth (Zp)


from from
Pile Top-m -1000.00 0 +1000.00 Pile Top-m
0 0

1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

9 9

10 10

11 11

12 12
Lateral Slope Vertical yt Slope Max.
No. Load Restraint Load at Top at Top Moment
13 (kN) (cm/cm) (kN) (cm) (cm/cm) (kN-m) 13
1 40.5 0.0 555.0 0.1 0.00 49.9
2 122.0 0.0 555.0 0.4 0.00 203.0
14 3 202.0 0.0 555.0 0.9 0.00 380.0 14
4 284.0 0.0 555.0 1.5 0.00 569.0
5 324.0 0.0 555.0 1.8 0.00 665.0
15 6 364.0 0.0 555.0 2.1 0.00 762.0 15
7 405.0 0.0 555.0 2.5 0.00 860.0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-12m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

LATERAL LOAD vs DEFLECTION & MAX. MOMENT

500 500

450 450

400 400

350 350

300 300
Lateral Load, P -kN

Lateral Load, P -kN


250 250

200 200

150 150

100 100

50 50

0 0
0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 0 90 180 270 360 450 540 630 720 810 900
Top Deflection, yt -cm Max. Moment in Single Pile, Mmax -kN-m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-12m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

P-Y curves for soils

800000

720000

640000

560000
p, -kN/m

480000

400000

320000

240000

160000

80000

0
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

y, -m
Depth: 1.5, 3.0, 4.5, 6.0, 7.5, 9.0, 10.5 -m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-12m
PILE STIFFNESS CALCULATION SHEET Ø600mm-12m LONG
USING BH-1 DATA
*****************************************************************
ALLPILE 6
PILE STIFFNESS ANALYSIS SUMMARY
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\
Ø600mm-12m long.alp
Title 1: Genex Investment
Title 2: Foundation Pile Ø600mm-12m

Single Pile Vertical Analysis:


Q= 555.00 -kN
Results:
At Work Load= 555.00-kN, Settlement, Xall= 0.18908-cm
Stiffness Kqx= 2935.21-kN/-cm

Single Pile Lateral Analysis - Free Head:

M= 0, P= 405.00 -kN
Results:
At Shear= 405.00-kN, Top Deflection, yt= 11.50000-cm
Stiffness Kpy= 35.22-kN/-cm
At Shear= 405.00-kN, Top Slope, St= -0.03060 Slope
Stiffness Kps= -13235.29-kN/Slope
Or St= -1.75270391 Degree, Stiffness Kps= -231.07-kN/Degree
P= 0, M= 10.00 -kN-m
Results:
At Moment= 10.00-kN, Top Deflection, yt= 0.00973-cm
Stiffness Kmy= 1027.75-kN-m/-cm
At Moment= 10.00-kN, Top Slope, St= -0.00010 Slope
Stiffness Kms= -96153.84-kN-m/Slope
Or St= -0.00595876 Degree, Stiffness Kms= -1678.20-kN-m/Degree

Single Pile Lateral Analysis - Fixed Head:

M= 0, P= 405.00 -kN
Results:
At Shear= 405.00-kN, Top Deflection, yt= 2.45000-cm
Stiffness Kpy= 165.31-kN/-cm
At Shear= 405.00-kN, Top Slope, St= 0.00000
Stiffness Kps= N/A
P= 0, M= 10.00 -kN-m
Results:
At Moment= 10.00-kN, Top Deflection, yt= 0.00000-cm
Stiffness Kmy= N/A
At Moment= 10.00-kN, Top Slope, St= 0.00000
Stiffness Kms= N/A
Notes:
Q - Vertical Load at pile top
P - Lateral Shear Load at pile top
M - Moment at pile top
Xall - Pile top total settlement
yt - Pile top deflection
St - Pile top deflection slope (deflection/unit length). Clockwise is negative
Kqx - Secant Stiffness: Vertical load vs. Vertical movement (settlement)
Kpy - Secant Stiffness: Lateral Shear vs. Lateral movement (deflection)
Kps - Secant Stiffness: Lateral Shear vs. Slope (rotation). Clockwise is negative
Kmy - Secant Stiffness: Moment vs. Lateral movement (deflection)
Kms - Secant Stiffness: Moment vs. Slope (rotation). Clockwise is negative

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
ETABS 18.1.1 License #*1VHQUC7UK2NRLHB

ETABS Concrete Frame Design


IS 456:2000 + IS 13920:2016 Column Section Design

RCC verification of 500mm Dia Pile-12m length-BH1

Column Element Details Type: Ductile Frame (Summary)


Level Element Unique Name Section ID Combo ID Station Loc Length (mm) LLRF
-3.0m C1 11 Ø500-6-Ø20+6-Ø25-Ø10-175 DL+LL 1500 1500 1

Section Properties
d (mm) h0 (mm) dc (mm) Cover (Torsion) (mm)
500 403.7 96.3 65

Material Properties
Ec (MPa) fck (MPa) Lt.Wt Factor (Unitless) fy (MPa) fys (MPa)
25000 25 1 500 500

Design Code Parameters


ɣC ɣS
1.5 1.15

Axial Force and Biaxial Moment Design For Pu , Mu2 , Mu3


Design Pu Design Mu2 Design Mu3 Minimum M2 Minimum M3 Rebar % Capacity Ratio
kN kN-m kN-m kN-m kN-m % Unitless
679.0378 13.5808 240.6207 13.5808 13.5808 2.47 0.92

Axial Force and Biaxial Moment Factors


K Factor Length Initial Moment Additional Moment Minimum Moment
Unitless mm kN-m kN-m kN-m
Major Bend(M3) 1.2 1500 199.4752 0 13.5808
Minor Bend(M2) 1.2 1500 0 0 13.5808

Shear Design for Vu2 , Vu3


Shear Vu Shear Vc Shear Vs Shear Vp Rebar Asv /s
kN kN kN kN mm²/m
Major, Vu2 68.576 174.7829 67.9438 0 554.22
Minor, Vu3 0 174.7829 67.9438 0 554.22

Joint Shear Check/Design

Revised Pile verification 500Dia-12m-BH1.EDB Page 1 of 2 5/1/2022


ETABS 18.1.1 License #*1VHQUC7UK2NRLHB

Joint Shear Shear Shear Shear Joint Shear


Force VTop Vu,Tot Vc Area Ratio
kN kN kN kN cm² Unitless
Major Shear, Vu2 N/A N/A N/A N/A N/A N/A
Minor Shear, Vu3 N/A N/A N/A N/A N/A N/A

(1.4) Beam/Column Capacity Ratio


Major Ratio Minor Ratio
N/A N/A

Additional Moment Reduction Factor k (IS 39.7.1.1)


Ag Asc Puz Pb Pu k
cm² cm² kN kN kN Unitless
1963.5 48.2 4003.7661 768.7347 679.0378 1

Additional Moment (IS 39.7.1)


Consider Length Section KL/Depth KL/Depth KL/Depth Ma
Ma Factor Depth (mm) Ratio Limit Exceeded Moment (kN-m)
Major Bending (M3 ) Yes 1 500 3.6 12 No 0
Minor Bending (M2 ) Yes 1 500 3.6 12 No 0

Notes:

N/A: Not Applicable

N/C: Not Calculated

N/N: Not Needed

Revised Pile verification 500Dia-12m-BH1.EDB Page 2 of 2 5/1/2022


VERTICAL CAPACITY PILE CALCULATION Ø600mm-14m LONG
USING BH-1 DATA
VERTICAL ANALYSIS Figure 1

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

Vertical Load, Q= 595.0 -kN


Shear Load, P= 0.0 -kN
Slope Restain St= 0.00 -cm/-cm

Profile:
Pile Length, L= 14.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0

Fixed Head Condition

Drilled Pile (dia <=24 in. or 61 cm)

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MP -kN/m
0 10.9 31.9 47.9 164.2 0.66 16 0.0 60 4410.2 188.5 664662.9 25000 8.236
1.5 12.2 26.4 150.8 672.0 0.33 50 13.0 60 4410.2 188.5 664662.9 25000 8.236
3.0 10.6 27.2 32.6 96.3 0.83 11 14.0 60 4410.2 188.5 664662.9 25000 7.069
4.5 9.8 0.0 41.9 48.7 1.08 7
14 11.2 0.0 143.0 278.5 0.51 24

Vertical capacity:
Weight above Ground= 0.00 Total Weight= 76.51-kN *Soil Weight is not included
Side Resistance (Down)= 623.581-kN Side Resistance (Up)= 596.604-kN
Tip Resistance (Down)= 363.886-kN Tip Resistance (Up)= 0.000-kN
Total Ultimate Capacity (Down)= 987.468-kN Total Ultimate Capacity (Up)= 673.116-kN
Total Allowable Capacity (Down)= 597.664-kN Total Allowable Capacity (Up)= 374.814-kN
OK! Qallow > Q

Settlement Calculation:
At Q= 595.00-kN Settlement= 0.11533-cm
At Xallow= 2.50-cm Qallow= 964.73578-kN

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-14m
*****************************************************************
ALLPILE 6
VERTICAL ANALYSIS SUMMARY OUTPUT
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\Ø600mm-14m long

Title 1: Genex Investment


Title 2: Foundation Pile Ø600mm-14m

TOTAL LOADS:
Vertical Load, Q: 595.0 -kN
Load Factor for Vertical Loads: 1.0
Loads Supported by Pile Cap: 0 %

PILE PROFILE:
Pile Length, L= 14.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0.00 Batter Factor, Kbat= 1.00

SINGLE PILE:
Deduction factor due to Group Effect, R= 1.00
Vertical Load= 595.00 -kN

Single Pile Vertical Analysis:


Results:
Total Ultimate Capacity (Down)= 987.47-kN, Total Ultimate Capacity (Up)= 673.12-kN
Total Allowable Capacity (Down)= 597.66-kN, Total Allowable Capacity (Up)= 374.81-kN
At Work Load= 595.00-kN, Settlement= 0.11533-cm
At Work Load= 595.00-kN, Secant Stiffness Kqx= 5159.27-kN/-cm
At Allowable Settlement= 2.500-cm, Capacity= 964.74-kN
Work Load, 595.00-kN, OK with the Capacity at Allowable Settlement= 2.50-cm, Capacity= 964.74-kN
Work Load, 595.00-kN, OK with the Allowable Capacity (Down)= 597.66-kN

____________________________________________
FACTOR OF SAFETY:
FSside FStip FSuplif FSweight
2.5 2 3 1

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

Concrete poured into drilled hole.


Diameter is limited to 24in (61cm).

FOUNDATION PROFILE & SOIL CONDITIONS

Depth FOUNDATION PROPERTIES SOIL PROPERTIES Depth


from from
Ground-m Ground-m
Depth Width-cm A'-cm2 Per.-cm I'-cm4 E -MP W -kN/m Depth  -kN/m3  C-kN/m2 k-MN/m3 e50 % Nspt
0 0
0.0 60 4410.2 188.5 664662.9 25000 8.236 0.0 10.9 31.9 47.9 164.2 0.66 16
Concrete (rough) Silt (Phi + C)

1 1

1.5 12.2 26.4 150.8 672.0 0.33 50


2 Silt (Phi + C) 2

3 3
3.0 10.6 27.2 32.6 96.3 0.83 11
Silt (Phi + C)

4 4

4.5 9.8 0.0 41.9 48.7 1.08 7


5 Stiff Clay 5

6 6

7 7

8 8

9 9

10 10

11 11

12 12

13 13
13.0 60 4410.2 188.5 664662.9 25000 8.236
Concrete (rough)

14 14
14.0 60 4410.2 188.5 664662.9 25000 7.069 14.0 11.2 0.0 143.0 278.5 0.51 24
Pile Tip Stiff Clay

15 15

Batter Angle=0 (Pile diameter not to scale) Surface Angle=0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-14m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

Vertical Load vs. Settlement

1000

900

800
Compression Load, Qdw -kN

700

600

500

400

300

200

100

0
0.0 0.3 0.5 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 2.8 3.0 3.3 3.5 3.8 4.0 4.3 4.5 4.8 5.0

Settlement, X -cm
Total Side Tip

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-14m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

ALLOWABLE CAPACITY vs FOUNDATION DEPTH

600 600

540 540

480 480
Compression Capacity, Qdw -kN

420 420

Uplift Capacity, Qup -kN


360 360

300 300

240 240

180 180

120 120

60 60

0 0
0 2 4 6 8 10 12 14 16 18 20 0 2 4 6 8 10 12 14 16 18 20
Foundation Depth, L -m Foundation Depth, L -m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-14m
LATERAL CAPACITY CALCULATION Ø600mm-14m
LONG USING BH-1
LATERAL ANALYSIS Figure 2

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

Vertical Load, Q= 595.0 -kN


Shear Load, P= 400.0 -kN
Slope Restain St= 0.00 -cm/-cm

Profile:
Pile Length, L= 14.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0

Fixed Head Condition

Drilled Pile (dia <=24 in. or 61 cm)

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MP -kN/m
0 10.9 31.9 47.9 164.2 0.66 16 0.0 60 4410.2 188.5 664662.9 25000 8.236
1.5 12.2 26.4 150.8 672.0 0.33 50 13.0 60 4410.2 188.5 664662.9 25000 8.236
3.0 10.6 27.2 32.6 96.3 0.83 11 14.0 60 4410.2 188.5 664662.9 25000 7.069
4.5 9.8 0.0 41.9 48.7 1.08 7
14 11.2 0.0 143.0 278.5 0.51 24
Single Pile Lateral Analysis:
Top Deflection, yt= 2.42000-cm
Max. Moment, M= 849.00-kN-m
Top Deflection Slope, St= 0.00000
OK! Top Deflection, 2.4200-cm is less than the Allowable Deflection= 2.50-cm

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
The Max. Moment calculated by program is an internal force from the applied load conditions. Structural engineer has to check whether
the pile has enough capacity to resist the moment with adequate factor of safety. If not, the pile may fail under the load conditions.

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-14m
*****************************************************************
ALLPILE 6
LATERAL ANALYSIS SUMMARY OUTPUT
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\
Ø600mm-14m long.alp
Title 1: Genex Investment
Title 2: Foundation Pile Ø600mm-14m

ILE PROFILES:
Pile Length, L= 14.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0.00

FACTORS AND CONDITIONS:


Load Factor for Vertical Loads: 1.0
Load Factor for Lateral Loads: 1.0
Loads Supported by Pile Cap: 0 %
Shear Condition: Static

SINGLE PILE:
Deduction factor due to Group Effect, R= 1.00
Vertical Load= 595.00 -kN
Shear= 400.00 -kN
Slope Restain, St= 0.00 -cm/-cm

Results:
Top Deflection, yt= 2.42000-cm
Max. Moment, M= 849.00-kN-m
Top Deflection Slope, St= 0.00000

Top Deflection, 2.4200-cm, OK with the Allowable Deflection= 2.50-cm


Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
____________________________________

Notes:
Q - Vertical Load at pile top
P - Lateral Shear Load at pile top
M - Moment at pile top
Xall - Pile top total settlement
yt - Pile top deflection
St - Pile top deflection slope (deflection/unit length)
The Max. Moment calculated by program is an internal moment of shaft due to the loading. Egineers
have to check whether the pile has enough moment capacity to resist the Max. Moment with adequate
factor of safety. If not, the pile may be damaged under the loading.
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE DEFLECTION & FORCE vs DEPTH


Single Pile, Khead=5, Kbc=2

Depth (Zp) DEFLECTION, yt -cm MOMENT -kN-m SHEAR -kN Pressure -kN/m2 Depth (Zp)
from from
Pile Top-m -5.00 0 +5.00 -1000 0 +1000 -500 0 +500 -100 0 +100 Pile Top-m
0 0

1 1

2 2

3 3

4 4

5 5

6 6
yt=0 at 6.4-m
St=0 at 0.1-m
7 7

8 8

9 9

10 10

11 11

12 12

13 13

14 14
Tip yt=-1.79E-4 Top yt=2.42E+0 Top Moment=-849.0 Top Shear=400.0
Max. yt=2.42E+0 Max. Moment=849.0 Max. Shear=407.1 Max. Pressure=51.67
Top St=0E+0
15 15

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-14m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE DEFLECTION vs LOADING


Single Pile, Khead=5, Kbc=2

Depth (Zp) DEFLECTION, yt -cm Depth (Zp)


from from
Pile Top-m -5.00 0 +5.00 Pile Top-m
0 0

1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

9 9

10 10

11 11

12 12
Lateral Slope Vertical yt Slope Max.
No. Load Restraint Load at Top at Top Moment
13 (kN) (cm/cm) (kN) (cm) (cm/cm) (kN-m) 13
1 40.0 0.0 595.0 0.1 0.00 49.3
2 120.0 0.0 595.0 0.4 0.00 200.0
14 3 200.0 0.0 595.0 0.9 0.00 375.0 14
4 280.0 0.0 595.0 1.5 0.00 562.0
5 320.0 0.0 595.0 1.8 0.00 657.0
15 6 360.0 0.0 595.0 2.1 0.00 753.0 15
7 400.0 0.0 595.0 2.4 0.00 849.0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-14m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE MOMENT vs LOADING


Single Pile, Khead=5, Kbc=2

Depth (Zp) MOMENT -kN-m Depth (Zp)


from from
Pile Top-m -1000.00 0 +1000.00 Pile Top-m
0 0

1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

9 9

10 10

11 11

12 12
Lateral Slope Vertical yt Slope Max.
No. Load Restraint Load at Top at Top Moment
13 (kN) (cm/cm) (kN) (cm) (cm/cm) (kN-m) 13
1 40.0 0.0 595.0 0.1 0.00 49.3
2 120.0 0.0 595.0 0.4 0.00 200.0
14 3 200.0 0.0 595.0 0.9 0.00 375.0 14
4 280.0 0.0 595.0 1.5 0.00 562.0
5 320.0 0.0 595.0 1.8 0.00 657.0
15 6 360.0 0.0 595.0 2.1 0.00 753.0 15
7 400.0 0.0 595.0 2.4 0.00 849.0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-14m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

LATERAL LOAD vs DEFLECTION & MAX. MOMENT

400 400

360 360

320 320

280 280

240 240
Lateral Load, P -kN

Lateral Load, P -kN


200 200

160 160

120 120

80 80

40 40

0 0
0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 0 90 180 270 360 450 540 630 720 810 900
Top Deflection, yt -cm Max. Moment in Single Pile, Mmax -kN-m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-14m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

P-Y curves for soils

300

270

240

210
p, -kN/m

180

150

120

90

60

30

0
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

y, -m
Depth: 1.8, 3.5, 5.3, 7.0, 8.8, 10.5, 12.3 -m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-14m
PILE STIFFNESS CALCULATION SHEET Ø600mm-14m LONG
USING BH-1 DATA
*****************************************************************
ALLPILE 6
PILE STIFFNESS ANALYSIS SUMMARY
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\
Ø500mm-14m long.alp
Title 1: Genex Investment
Title 2: Foundation Pile Ø500mm-14m

Single Pile Vertical Analysis:


Q= 595.00 -kN
Results:
At Work Load= 595.00-kN, Settlement, Xall= 0.18046-cm
Stiffness Kqx= 3297.20-kN/-cm

Single Pile Lateral Analysis - Free Head:

M= 0, P= 400.00 -kN
Results:
At Shear= 400.00-kN, Top Deflection, yt= 11.40000-cm
Stiffness Kpy= 35.09-kN/-cm
At Shear= 400.00-kN, Top Slope, St= -0.03020 Slope
Stiffness Kps= -13245.03-kN/Slope
Or St= -1.72980678 Degree, Stiffness Kps= -231.24-kN/Degree
P= 0, M= 10.00 -kN-m
Results:
At Moment= 10.00-kN, Top Deflection, yt= 0.00970-cm
Stiffness Kmy= 1030.93-kN-m/-cm
At Moment= 10.00-kN, Top Slope, St= -0.00010 Slope
Stiffness Kms= -96153.84-kN-m/Slope
Or St= -0.00595876 Degree, Stiffness Kms= -1678.20-kN-m/Degree

Single Pile Lateral Analysis - Fixed Head:

M= 0, P= 400.00 -kN
Results:
At Shear= 400.00-kN, Top Deflection, yt= 2.42000-cm
Stiffness Kpy= 165.29-kN/-cm
At Shear= 400.00-kN, Top Slope, St= 0.00000
Stiffness Kps= N/A
P= 0, M= 10.00 -kN-m
Results:
At Moment= 10.00-kN, Top Deflection, yt= 0.00000-cm
Stiffness Kmy= N/A
At Moment= 10.00-kN, Top Slope, St= 0.00000
Stiffness Kms= N/A
Notes:
Q - Vertical Load at pile top
P - Lateral Shear Load at pile top
M - Moment at pile top
Xall - Pile top total settlement
yt - Pile top deflection
St - Pile top deflection slope (deflection/unit length). Clockwise is negative
Kqx - Secant Stiffness: Vertical load vs. Vertical movement (settlement)
Kpy - Secant Stiffness: Lateral Shear vs. Lateral movement (deflection)
Kps - Secant Stiffness: Lateral Shear vs. Slope (rotation). Clockwise is negative
Kmy - Secant Stiffness: Moment vs. Lateral movement (deflection)
Kms - Secant Stiffness: Moment vs. Slope (rotation). Clockwise is negative

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
VERTICAL CAPACITY PILE CALCULATION Ø600mm-16m LONG
USING BH-1 DATA
VERTICAL ANALYSIS Figure 1

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

Vertical Load, Q= 640.0 -kN


Shear Load, P= 0.0 -kN
Slope Restain St= 0.00 -cm/-cm

Profile:
Pile Length, L= 16.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0

Fixed Head Condition

Drilled Pile (dia <=24 in. or 61 cm)

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MP -kN/m
0 10.9 31.9 47.9 164.2 0.66 16 0.0 60 4410.2 188.5 664662.9 25000 8.236
1.5 12.2 26.4 150.8 672.0 0.33 50 15.0 60 4410.2 188.5 664662.9 25000 8.236
3.0 10.6 27.2 32.6 96.3 0.83 11 16.0 60 2827.4 188.5 664662.9 25000 7.069
4.5 9.8 0.0 41.9 48.7 1.08 7
16 11.2 0.0 143.0 278.5 0.51 24

Vertical capacity:
Weight above Ground= 0.00 Total Weight= 87.44-kN *Soil Weight is not included
Side Resistance (Down)= 688.583-kN Side Resistance (Up)= 661.535-kN
Tip Resistance (Down)= 363.886-kN Tip Resistance (Up)= 0.000-kN
Total Ultimate Capacity (Down)= 1052.470-kN Total Ultimate Capacity (Up)= 748.977-kN
Total Allowable Capacity (Down)= 640.999-kN Total Allowable Capacity (Up)= 418.210-kN
OK! Qallow > Q

Settlement Calculation:
At Q= 640.00-kN Settlement= 0.11654-cm
At Xallow= 2.50-cm Qallow= 1025.34253-kN

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-16m
*****************************************************************
ALLPILE 6
VERTICAL ANALYSIS SUMMARY OUTPUT
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\Ø600mm-16m long

Title 1: Genex Investment


Title 2: Foundation Pile Ø600mm-16m

TOTAL LOADS:
Vertical Load, Q: 641.0 -kN
Load Factor for Vertical Loads: 1.0
Loads Supported by Pile Cap: 0 %

PILE PROFILE:
Pile Length, L= 16.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0.00 Batter Factor, Kbat= 1.00

SINGLE PILE:
Deduction factor due to Group Effect, R= 1.00
Vertical Load= 641.00 -kN

Single Pile Vertical Analysis:


Results:
Total Ultimate Capacity (Down)= 1052.47-kN, Total Ultimate Capacity (Up)= 748.98-kN
Total Allowable Capacity (Down)= 641.00-kN, Total Allowable Capacity (Up)= 418.21-kN
At Work Load= 640.00-kN, Settlement= 0.11654-cm
At Work Load= 640.00-kN, Secant Stiffness Kqx= 5491.85-kN/-cm
At Allowable Settlement= 2.500-cm, Capacity= 1025.34-kN
Work Load, 640.00-kN, OK with the Capacity at Allowable Settlement= 2.50-cm, Capacity= 1025.34-kN
Work Load, 640.00-kN, OK with the Allowable Capacity (Down)= 641.00-kN

____________________________________________
FACTOR OF SAFETY:
FSside FStip FSuplif FSweight
2.5 2 3 1

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

Concrete poured into drilled hole.


Diameter is limited to 24in (61cm).

FOUNDATION PROFILE & SOIL CONDITIONS

Depth FOUNDATION PROPERTIES SOIL PROPERTIES Depth


from from
Ground-m Ground-m
Depth Width-cm A'-cm2 Per.-cm I'-cm4 E -MP W -kN/m Depth  -kN/m3  C-kN/m2 k-MN/m3 e50 % Nspt
0 0
0.0 60 4410.2 188.5 664662.9 25000 8.236 0.0 10.9 31.9 47.9 164.2 0.66 16
Concrete (rough) Silt (Phi + C)

2 1.5 12.2 26.4 150.8 672.0 0.33 50 2


Silt (Phi + C)

3.0 10.6 27.2 32.6 96.3 0.83 11


4 Silt (Phi + C) 4
4.5 9.8 0.0 41.9 48.7 1.08 7
Stiff Clay
6 6

8 8

10 10

12 12

14 14

15.0 60 4410.2 188.5 664662.9 25000 8.236


16 Concrete (rough) 16
16.0 11.2 0.0 143.0 278.5 0.51 24
16.0 60 2827.4 188.5 664662.9 25000 7.069 Stiff Clay
Pile Tip
18 18

20 20

22 22

24 24

26 26

28 28

30 30

Batter Angle=0 (Pile diameter not to scale) Surface Angle=0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-16m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

Vertical Load vs. Settlement

2000

1800

1600
Compression Load, Qdw -kN

1400

1200

1000

800

600

400

200

0
0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 5.7 6.0

Settlement, X -cm
Total Side Tip

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-16m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

ALLOWABLE CAPACITY vs FOUNDATION DEPTH

700 700

630 630

560 560
Compression Capacity, Qdw -kN

490 490

Uplift Capacity, Qup -kN


420 420

350 350

280 280

210 210

140 140

70 70

0 0
0 2 4 6 8 10 12 14 16 18 20 0 2 4 6 8 10 12 14 16 18 20
Foundation Depth, L -m Foundation Depth, L -m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-16m
LATERAL CAPACITY CALCULATION Ø600mm-16m
LONG USING BH-1
LATERAL ANALYSIS Figure 2

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

Vertical Load, Q= 640.0 -kN


Shear Load, P= 405.0 -kN
Slope Restain St= 0.00 -cm/-cm

Profile:
Pile Length, L= 16.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0

Fixed Head Condition

Drilled Pile (dia <=24 in. or 61 cm)

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MP -kN/m
0 10.9 31.9 47.9 164.2 0.66 16 0.0 60 4410.2 188.5 664662.9 25000 8.236
1.5 12.2 26.4 150.8 672.0 0.33 50 15.0 60 4410.2 188.5 664662.9 25000 8.236
3.0 10.6 27.2 32.6 96.3 0.83 11 16.0 60 2827.4 188.5 664662.9 25000 7.069
4.5 9.8 0.0 41.9 48.7 1.08 7
16 11.2 0.0 143.0 278.5 0.51 24
Single Pile Lateral Analysis:
Top Deflection, yt= 2.46000-cm
Max. Moment, M= 860.00-kN-m
Top Deflection Slope, St= 0.00000
OK! Top Deflection, 2.4600-cm is less than the Allowable Deflection= 2.50-cm

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
The Max. Moment calculated by program is an internal force from the applied load conditions. Structural engineer has to check whether
the pile has enough capacity to resist the moment with adequate factor of safety. If not, the pile may fail under the load conditions.

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-16m
*****************************************************************
ALLPILE 6
LATERAL ANALYSIS SUMMARY OUTPUT
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\
Ø600mm-16m long.alp
Title 1: Genex Investment
Title 2: Foundation Pile Ø600mm-16m

PILE PROFILES:
Pile Length, L= 16.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0.00

FACTORS AND CONDITIONS:


Load Factor for Vertical Loads: 1.0
Load Factor for Lateral Loads: 1.0
Loads Supported by Pile Cap: 0 %
Shear Condition: Static

SINGLE PILE:
Deduction factor due to Group Effect, R= 1.00
Vertical Load= 640.00 -kN
Shear= 405.00 -kN
Slope Restain, St= 0.00 -cm/-cm

Results:
Top Deflection, yt= 2.46000-cm
Max. Moment, M= 860.00-kN-m
Top Deflection Slope, St= 0.00000

Top Deflection, 2.4600-cm, OK with the Allowable Deflection= 2.50-cm


Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
____________________________________

Notes:
Q - Vertical Load at pile top
P - Lateral Shear Load at pile top
M - Moment at pile top
Xall - Pile top total settlement
yt - Pile top deflection
St - Pile top deflection slope (deflection/unit length)
The Max. Moment calculated by program is an internal moment of shaft due to the loading. Egineers
have to check whether the pile has enough moment capacity to resist the Max. Moment with adequate
factor of safety. If not, the pile may be damaged under the loading.
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE DEFLECTION & FORCE vs DEPTH


Single Pile, Khead=5, Kbc=2

Depth (Zp) DEFLECTION, yt -cm MOMENT -kN-m SHEAR -kN Pressure -kN/m2 Depth (Zp)
from from
Pile Top-m -5.00 0 +5.00 -1000 0 +1000 -500 0 +500 -100 0 +100 Pile Top-m
0 0

2 2

4 4

6 yt=0 at 6.4-m 6

St=0 at 7.8-m
8 8

10 10

12 12

14 14

16 16
Tip yt=-4.6E-5 Top yt=2.46E+0 Top Moment=-860.0 Top Shear=405.0
Max. yt=2.46E+0 Max. Moment=860.0 Max. Shear=412.5 Max. Pressure=52.08
Top St=1.07E-17
18 18

20 20

22 22

24 24

26 26

28 28

30 30

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-16m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE DEFLECTION vs LOADING


Single Pile, Khead=5, Kbc=2

Depth (Zp) DEFLECTION, yt -cm Depth (Zp)


from from
Pile Top-m -5.00 0 +5.00 Pile Top-m
0 0

2 2

4 4

6 6

8 8

10 10

12 12

14 14

16 16

18 18

20 20

22 22

24 24
Lateral Slope Vertical yt Slope Max.
No. Load Restraint Load at Top at Top Moment
26 (kN) (cm/cm) (kN) (cm) (cm/cm) (kN-m) 26
1 40.5 0.0 640.0 0.1 0.00 49.9
2 122.0 0.0 640.0 0.4 0.00 203.0
28 3 202.0 0.0 640.0 0.9 0.00 380.0 28
4 284.0 0.0 640.0 1.5 0.00 569.0
5 324.0 0.0 640.0 1.8 0.00 666.0
30 6 364.0 0.0 640.0 2.1 0.00 762.0 30
7 405.0 0.0 640.0 2.5 0.00 860.0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-16m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

PILE MOMENT vs LOADING


Single Pile, Khead=5, Kbc=2

Depth (Zp) MOMENT -kN-m Depth (Zp)


from from
Pile Top-m -1000.00 0 +1000.00 Pile Top-m
0 0

2 2

4 4

6 6

8 8

10 10

12 12

14 14

16 16

18 18

20 20

22 22

24 24
Lateral Slope Vertical yt Slope Max.
No. Load Restraint Load at Top at Top Moment
26 (kN) (cm/cm) (kN) (cm) (cm/cm) (kN-m) 26
1 40.5 0.0 640.0 0.1 0.00 49.9
2 122.0 0.0 640.0 0.4 0.00 203.0
28 3 202.0 0.0 640.0 0.9 0.00 380.0 28
4 284.0 0.0 640.0 1.5 0.00 569.0
5 324.0 0.0 640.0 1.8 0.00 666.0
30 6 364.0 0.0 640.0 2.1 0.00 762.0 30
7 405.0 0.0 640.0 2.5 0.00 860.0

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-16m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

LATERAL LOAD vs DEFLECTION & MAX. MOMENT

500 500

450 450

400 400

350 350

300 300
Lateral Load, P -kN

Lateral Load, P -kN


250 250

200 200

150 150

100 100

50 50

0 0
0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 0 90 180 270 360 450 540 630 720 810 900
Top Deflection, yt -cm Max. Moment in Single Pile, Mmax -kN-m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-16m
ALL-PILE Version 6 CivilTech Software www.civiltech.com Licensed to

P-Y curves for soils

300

270

240

210
p, -kN/m

180

150

120

90

60

30

0
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00

y, -m
Depth: 2.0, 4.0, 6.0, 8.0, 10.0, 12.0, 14.0 -m

Sanju Jain Geotech Firm Genex Investment


All pIle Software Foundation Pile Ø600mm-16m
PILE STIFFNESS CALCULATION SHEET Ø600mm-16m LONG
USING BH-1 DATA
*****************************************************************
ALLPILE 6
PILE STIFFNESS ANALYSIS SUMMARY
Copyright by CivilTech Software 2005
www.civiltech.com
(425) 453-6488 Fax (425) 453-5848
*****************************************************************
Licensed to
Date: 5/1/2022 File: E:\Geotech solutions\2022\Uttar Dokha Protection piles\All Pile-model\BH-1\
Ø600mm-16m long.alp
Title 1: Genex Investment
Title 2: Foundation Pile Ø600mm-16m

Single Pile Vertical Analysis:


Q= 640.00 -kN
Results:
At Work Load= 640.00-kN, Settlement, Xall= 0.17910-cm
Stiffness Kqx= 3573.34-kN/-cm

Single Pile Lateral Analysis - Free Head:

M= 0, P= 405.00 -kN
Results:
At Shear= 405.00-kN, Top Deflection, yt= 11.60000-cm
Stiffness Kpy= 34.91-kN/-cm
At Shear= 405.00-kN, Top Slope, St= -0.03080 Slope
Stiffness Kps= -13149.35-kN/Slope
Or St= -1.76415229 Degree, Stiffness Kps= -229.57-kN/Degree
P= 0, M= 10.00 -kN-m
Results:
At Moment= 10.00-kN, Top Deflection, yt= 0.00977-cm
Stiffness Kmy= 1023.54-kN-m/-cm
At Moment= 10.00-kN, Top Slope, St= -0.00010 Slope
Stiffness Kms= -96153.84-kN-m/Slope
Or St= -0.00595876 Degree, Stiffness Kms= -1678.20-kN-m/Degree

Single Pile Lateral Analysis - Fixed Head:

M= 0, P= 405.00 -kN
Results:
At Shear= 405.00-kN, Top Deflection, yt= 2.46000-cm
Stiffness Kpy= 164.63-kN/-cm
At Shear= 405.00-kN, Top Slope, St= 0.00000
Stiffness Kps= N/A
P= 0, M= 10.00 -kN-m
Results:
At Moment= 10.00-kN, Top Deflection, yt= 0.00000-cm
Stiffness Kmy= N/A
At Moment= 10.00-kN, Top Slope, St= 0.00000
Stiffness Kms= N/A
Notes:
Q - Vertical Load at pile top
P - Lateral Shear Load at pile top
M - Moment at pile top
Xall - Pile top total settlement
yt - Pile top deflection
St - Pile top deflection slope (deflection/unit length). Clockwise is negative
Kqx - Secant Stiffness: Vertical load vs. Vertical movement (settlement)
Kpy - Secant Stiffness: Lateral Shear vs. Lateral movement (deflection)
Kps - Secant Stiffness: Lateral Shear vs. Slope (rotation). Clockwise is negative
Kmy - Secant Stiffness: Moment vs. Lateral movement (deflection)
Kms - Secant Stiffness: Moment vs. Slope (rotation). Clockwise is negative

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
ETABS 18.1.1 License #*1VHQUC7UK2NRLHB

ETABS Concrete Frame Design


IS 456:2000 + IS 13920:2016 Column Section Design

RCC verification of 600mm Dia Pile-16m length-BH3

Column Element Details Type: Ductile Frame (Summary)


Level Element Unique Name Section ID Combo ID Station Loc Length (mm) LLRF
-0m C1 13 Ø600-6-Ø20+6-Ø25-Ø10-175 DL+LL 0 1500 1

Section Properties
d (mm) h0 (mm) dc (mm) Cover (Torsion) (mm)
600 503.7 96.3 65

Material Properties
Ec (MPa) fck (MPa) Lt.Wt Factor (Unitless) fy (MPa) fys (MPa)
25000 25 1 500 500

Design Code Parameters


ɣC ɣS
1.5 1.15

Axial Force and Biaxial Moment Design For Pu , Mu2 , Mu3


Design Pu Design Mu2 Design Mu3 Minimum M2 Minimum M3 Rebar % Capacity Ratio
kN kN-m kN-m kN-m kN-m % Unitless
1017.8696 23.411 388.6925 23.411 23.411 1.72 0.98

Axial Force and Biaxial Moment Factors


K Factor Length Initial Moment Additional Moment Minimum Moment
Unitless mm kN-m kN-m kN-m
Major Bend(M3) 1.2 1500 233.2155 0 23.411
Minor Bend(M2) 1.2 1500 0 0 23.411

Shear Design for Vu2 , Vu3


Shear Vu Shear Vc Shear Vs Shear Vp Rebar Asv /s
kN kN kN kN mm²/m
Major, Vu2 259.1283 227.3473 101.3627 0 665.06
Minor, Vu3 0 227.3473 101.3627 0 665.06

Joint Shear Check/Design

Revised Pile verification 600Dia-16m-BH3.EDB Page 1 of 2 5/1/2022


ETABS 18.1.1 License #*1VHQUC7UK2NRLHB

Joint Shear Shear Shear Shear Joint Shear


Force VTop Vu,Tot Vc Area Ratio
kN kN kN kN cm² Unitless
Major Shear, Vu2 N/A N/A N/A N/A N/A N/A
Minor Shear, Vu3 N/A N/A N/A N/A N/A N/A

(1.4) Beam/Column Capacity Ratio


Major Ratio Minor Ratio
N/A N/A

Additional Moment Reduction Factor k (IS 39.7.1.1)


Ag Asc Puz Pb Pu k
cm² cm² kN kN kN Unitless
2827.4 48.2 4969.4632 1295.4097 1017.8696 1

Additional Moment (IS 39.7.1)


Consider Length Section KL/Depth KL/Depth KL/Depth Ma
Ma Factor Depth (mm) Ratio Limit Exceeded Moment (kN-m)
Major Bending (M3 ) Yes 1 600 3 12 No 0
Minor Bending (M2 ) Yes 1 600 3 12 No 0

Notes:

N/A: Not Applicable

N/C: Not Calculated

N/N: Not Needed

Revised Pile verification 600Dia-16m-BH3.EDB Page 2 of 2 5/1/2022


1 2 3 4 5 6 7 8 9

F F

E E

D D

A1.01

C C

B B

A1.01

A A

..... ..... .....

Sheet Number
NOTES : PROJECT : DRAWING TITLE : Scale :-1: 50, 16, 10

ALL DIMENSIONS ARE MILLIMETER. Date :-


UNLESS OTHERWISE NOTED GENEX INVESTMENT FOUNDATION PILE DESIGN DRAWINGS SANJU GEOTECH ENGINEER FIRM PVT. LTD.
8/3/2021
S1.01
Drawn By:-
Ø500MM-12M, 14, AND 16M LONG
BUILDING BAGDOL, LALITPUR PSR Sheet

Design By:-
SKJ
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9

F F

E E

D D

C C

B B

A A

..... ..... .....

Sheet Number
NOTES : PROJECT : DRAWING TITLE : Scale :-1: 50, 16, 10

ALL DIMENSIONS ARE MILLIMETER. Date :-


UNLESS OTHERWISE NOTED GENEX INVESTMENT FOUNDATION PILE DESIGN DRAWINGS SANJU GEOTECH ENGINEER FIRM PVT. LTD.
8/3/2021
S1.02
Drawn By:-
Ø600MM-12M, 14, AND 16M LONG
BUILDING BAGDOL, LALITPUR PSR Sheet

Design By:-
SKJ
1 2 3 4 5 6 7 8 9

You might also like