Professional Documents
Culture Documents
PSC Hallow Bridge
PSC Hallow Bridge
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Prestressed Concrete Circular Hollow Pole/Pile Design Based on ACI 318-11 & AASHTO 17th
PRESTRESSING STRAND 16 strands (each 12.7 mm dia. & 98.7 mm2 area )
(each 0.50 in dia. & 0.153 in2 area )
STRAND FORCE IMMEDIATELY AFTER PRESTRESS TRANSFER 0.75 fpy, (ACI 318-11 18.5) Pi = 1981.7 kN
445.9 kips
STRAND FORCE AT SERVICE LOAD AFTER ALLOWANCE LOSSES 0.6 fpy, (ACI 318-11 18.6) Pe = 1585.3 kN
356.7 kips
VERTICAL REINFORCEMENT ( 0 bars for not apply) 4 # 5
LATERAL REINF. OPTION (0=Spirals, 1=Ties) 0 Spirals
LATERAL REINFORCEMENT # 4 @ 305 mm o.c.
12.0 in o.c.
ANALYSIS
CHECK TRANSFER (SHIPPING & ERECTION) LOAD CONDITION (ACI 318 18.4.1, 18.5.1, AASHTO 9.15.1 & 9.15.2.1)
TENSION FIBER STRESS - Fti = -0.711 ksi, (AASHTO 9.15.2.1)
COMPRESSION FIBER STRESS Fpi = 5.394 ksi, (AASHTO 9.15.2.1)
STRAND ALLOWABLE STRESS Fsi = 215.99 ksi, (ACI 318 18.5.1)
Pi P M
f pi 4.670 ksi < Fpi
A A S
[Satisfactory]
CHECK ULTIMATE LOAD CONDITION (AASHTO 9.15.1 & 9.17 ACI 318-11 18.7)
2000.00
2 0.85 f C' '
o , E c 57 f C , E s 29000ksi
Ec
1500.00
2
f Pn (k)
0.85 f
'
C
2 c c , for 0 c o
1000.00 f C o o
'
0.85 f
C , for c o
500.00
s E s , for s y
f S
f , for s y
0.00 y
0.00 100.00 200.00 300.00 400.00 500.00 600.00 700.00
P
f Min s E s e , F se
-500.00 PS
A ps
-1000.00
f Mn (ft-k)