Filtro RFM ON 185 V D 10 E 1.x (Hydac)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

RFM ON 185 V D 10 E 1.

x
TECHNICAL DATA
Part number 1298932
Pmax * 7 bar
Qmax * 185 l/min
Return line conn. G1
Return line conn. opt. Without
Material Aluminium, plastic
Seal material NBR
Bypass valve 3.0 bar
Temperature range * -30 °C to 100 °C (short-term -40 °C)
Weight w ith element [kg] 1,14

SPARE ELEMENT(S)
Designation 0185 R 010 ON
Part number 1290110
Number elem.(s)/side 1
Filter material Optimicron®, Dpmax=20 bar
Filter rating (acc. to ISO 16889) 11.4 µm at βx(c) = 1000
Cont. retention cap. (acc. to ISO 16889) 33.0 g at 2.0 bar
Differential pressure stability * 20 bar
Slope coefficient 0.002933833 bar / (l/min)

CLOGGING INDICATOR(S)
Designation VMF 2 E.x
Part number 303854
CI response pressure 2.0 bar
Pressure gauge, connection on the back (absolute pres-
Design
sure)
Measurement of Back-pressure
Pmax * 7 bar

DIMENSIONS
Installation space of filter (without indicator)
Clogging Indicator
Element

Creator: Guest User HYDAC Filtertechnik GmbH - Filter-IT² 1.0 – 12.07.2022


Company: *) Exceeding the mentioned and approved technical values can lead to malfunctions or destruction of the product.
Project: HYDAC dimensioning recommendations: We recommend a filter selection at a differential pressure of 20 % of the response pressu re of the clogging indicator. 1/2
T hat means a recommended differential pressure with clean element of: <br>· 1 - 1.5 bar for pressure filters <br>· 0.5 - 0.6 bar for return line filters <br>· 0.05
bar for suction filters
RFM ON 185 V D 10 E 1.x

CHARACTERISTICS
Pressure / Flow Pressure / Temperature

Total: Housing: Element(s):

OPERATING CONDITIONS FOR THE FILTER


Medium MOBIL DTE 68 Δp at 180 l/m in
Selecting temperature 55 °C Total 0.810 bar
Selecting viscosity 33.97 mm²/s Element(s) 0.598 bar
Cold Start Viscosity -
Flow 180 l/min

SPARE PARTS LIST


Part num- Num-
Pos. Spare Parts Designation
ber ber
1 Filter element(s) per side 1290110 0185 R 010 ON 1
2 Clogging indicator 303854 VMF 2 E.x 1
3 Repairing set 313158 REPARATURSATZ-E RFM..165 G 1.1 1

Creator: Guest User HYDAC Filtertechnik GmbH - Filter-IT² 1.0 – 12.07.2022


Company: T he information in this brochure relates to the operating conditions and applications described. For applications or operatin g conditions not described, please
Project: contact the relevant technical department. Subject to technical modifications. 2/2
HYDAC dimensioning recommendations: We recommend a filter selection at a differential pressure of 20 % of the response pressu re of the clogging indicator.
T hat means a recommended differential pressure with clean element of: <br>· 1.0 - 1.5 bar for pressure filters <br>· 0.5 - 0.6 bar for return line filters <br>·
0.05 bar for suction filters