Download as pdf or txt
Download as pdf or txt
You are on page 1of 68

Company Introduction

Hebei Create Instrumentation

Technologies Co., Ltd. is a

professional developer and

manufacturer of Industrial

on-line instruments since 1988,

such as: Conductivity/

Resistivity meter, pH /ORP

meter, Reverse Osmosis controller, Flow meter and Sensors. Our instruments could

be widely used in: Water treatment, Electronic power, chemical industry, Pharmacy,

Environment protection.

We have substantial market share in China, almost70%. Our instruments are popular,

not only in China, but also in International market. With strong scientific and

technical strength, our products have been exported to more than40 countries

covering Asia, Europe, American, Oceania, and Africa. Our instruments earn good

reputation in domestic and aboard market due to high quality and reasonable price.

Our company has a high-level team for

technology researching &developing , a high

efficient group for quality control ,production

management and sale & service and

possesses advanced production line for

inserting, installing, SMT, soldering and after making and facilities for measure,

demarcating and check.


We take customers and quality as our life and

improve products continuously and create new

series products. With 20 years of history, we are

always advancing higher and pursuing excellence

and hold operation principle of technology

innovation, reliable service and customers first to

serve customers and friends. We are doing every effort to thank good cooperation

and great support of many years from our customers with our continuous process,

good products, competitive price and

circumspect service.

Honors:

1988 First patent of Industrial Pure water

conductivity

2003 Hebei Technology Innovation Enterprise of Measurement Instruments Industry

2004 Hi-tech Enterprise of Hebei Province and honor the Financing and Technical support.

2005 ISO9001:2000 system accreditation

2006 CE accreditation
SERIES OF Industrial Circulation Cooling Water Controller
DCK-6500 Industrial Circulation Cooling Water Controller
Features and application
The DCK-6500 is a kind of intelligent controller
for conductivity measurement and Chemicals
dosing of industrial circulation cooling water.
The meter is not only used for the Conductivity &
Temperature measurement of the Enclosed type
circulation cooling water systems and Opening type
systems , but also widely used for the adjustment
of water chemical dosing.
Be based on monitoring the conductivity value of
the industrial circulation cooling water to control
the concentration multiple of the cooling water, and
then drainge and water supplement in time. Control
the dosing According to the time proportion, the drainge, the water supplement to cuculate the dosing ,
which will protect the pipeline from corrsion , improve the heat exchange efficiency, reduce the energy
consumption.
The meter is widely used for the circulation cooling water system of Central Air-condictioning,Petroleum
Chemical Industry, Metallurgy, Thermo Power plants, Chemical fertilizer plant.

Conductivity over-limited warning; No reagent warning; circulationg water over temperaure warning
Multi-sensors conductivity measurement; strong ability of anti-pollution; large measurement range ; high
level accurate.

The double channels of the measurement will offer the data of water supplyment, drianage and so on.
Corrosion inhibitor, sterilizing agent will be dosing by timing.
The measurement data could be record for the paperless function.

Main technical index


Protect level IP65 ( The diameter of the wire that connect with the terminal
should be ≥5mm)
Measurement range:200~ 20000μS/cm (0~ 25000ppm)
Temperature compensation:0 ~ 50℃ (273~ 323K)
Conductivity Sensor:Multi-Conductivity sensor
measurement Accurate:±5% (FS) ± 1Digits
Material: Titanium
Cleaning:Ultrasonic cleaning
Temperature Components of temperature measurement:Pt1000
measurement of Accurate:±1℃
Circulating water. Measurement range:0 ~ 60 ℃ (273~333K)
Sort of Chemicals Dosing the Corrosion inhibitor on the drain/water supplement:
Double channels
adding
Dosing the sterilizing agent time period: One channel
Flow meter pulse signal:Double channels (one is for drainage, the
other one is for water supplyment)
Switching value
Switch of low liquid leve( solution box):triplicate channels
signal input
Switch of flux ( NO type ):one channel
Switch of liquid level ( NO type ):double channels
Metering pump control output: triplicate channels
Switching value Solenoid valve control output:triplicate channels
signal output Alarm control output:one channel
Ultrasonic cleaning control output:one channel
Analog output 0~20mA isolated output (corresponding to the conductivity):
one channel ( load capacity≤400Ω)
Communication port RS-485 serial port:one channel
Port 320x240 LCD screen with background light; 6 pieces of press keys
Working environment Temperature: 0 ~ 60 ℃; Humidity:≤80% RH
Power supply AC 220V±10% 50Hz; Power consumption:≤10W
Dimension 320×260×129mm
Weight 5.3kg
Installation Wall hanging.
DCK-6600 Industrial Circulation Cooling Water Controller
Features and applications:
The DCK-6600 is a kind of intelligent controller for conductivity measurement and Chemicals dosing of
industrial circulation cooling water.
The meter is not only used for the Conductivity &
Temperature measurement of the Enclosed type
circulation cooling water systems and Opening type
systems , but also widely used for the adjustment of
water chemical dosing.
The double channels of the measurement will offer the
data of water supplyment, drianage and so on.
Multi-sensors conductivity measurement; strong ability
of anti-pollution; large measurement range ; high level
accurate.
The RS485 data port could work with the epigyny
device to transfer data to the PC computer for Network
remote control and setti
Main features and applications:
Protect leverl IP65 The diameter of the wire that connect with the terminal should
be≥5mm)
Measurement range:200~ 20000μS/cm (0~ 10000ppm)
Temperature compensation range:0~ 50℃ (273~ 323K)
Conductivity Sensor:Multi-conductivity sensor
measuremnt Accurate:±5%±1Digitals
Material:Titanium
Cleaning :Ultrasonic cleaning
Sensor :pH sensor
Measurement range:2~ 12pH
Accurate:0.1pH
Measurement resolution:0.01pH
pH measurement
Stability:±0.05pH/24h
Working temperature:-15-80℃
Max pressure:0.6MPa
Life span:1 Year
Components of temperature measurement:Pt1000
Temperature
Accurate:±1℃
measurement
Measurement range:0 ~ 100℃ (273~373K)
Flow meter pulse signal:double channels
Switch value signal
Switch of Flux ( Normally Open type ) :one channel
input
Swith of Liquid level ( Normally Open type ):double channels
Switch value signal Solenoid control output:double channels
output Warning control output:one channel
pH dosing :one channel
Ultrasonice cleaning control output :one channel
Anolog output 0~20mA isolated output (corresponding to the conductivity) :
one channel (Load capacity≤500Ω)
Communication port RS-485 serial port:one channel
port 240x160 LCD screen with background light; 6 pieces of press keys
Working condictions. Temperature:0 ~ 60 ℃; Humidity:≤80% RH
Power supply AC 220V±10% 50Hz; power consumption:≤10W
Demension 235×185×119mm
Installation Wall hanging
PMC-6100 Pool Water Controller
Features and applications
PMC-6100 is a kind of intelligent
controller with microprocessor
controlling. The meter is a
Programmble controller that being
used for the pH , ORP, temperature,
liquid level, TDS measurement.
The intelligent meter PMC-6100 could
controlling and monitoring the water
quality, temperature, water valume and
dosing of the Hotel, Swimming pool,
Hot spring... The meter needs less
spaces, less operation charge and easily operate.

Main technical index


IP65(The diameter of the wire that connect with the terminal should
Protect level
be≥5mm)
Measurement range:200~ 20000μS/cm (0~ 10000ppm)
Temperature compensation:0~ 50℃ (273~ 323K)
Conductivity Sensor:Multi-conductivity sensor
measurement Accurate:±5%±1Digitals
Material:Titanium
Cleaning:Ultrasonic cleaning
Sensor:pH sensor
Measurement range:2~12pH
Accurate:0.1pH
Resolution:0.1pH
pH measurement
Stability:±0.2pH/24h
Working temperature:-15~80℃
Max pressure :0.6MPa
Life span :1 Year
Sensor:ORP sensor
Measurement range :0 ~ 900mV
Accurate:5mV
Resolution:1mV
ORP measurement Stability:±10mV/24h
Working temperature:-15~80℃
Max pressure:0.6Mpa

Sensor:Pt1000
Water temperature Accurate:±0.5℃
Measurement range:0 ~ 56 ℃ (273~ 373K)
measurement
Resolution:0.1℃
Stability:±1℃/24h
Components of measurement:TDS sensor
Accurate:±2%
TDS measurement Measurement range:200 ~ 20000 ppm (mg/L)
Resolution:±1%
Stability:±2%/24h
Dosing solenoid control output: triplicat channels
Switching value Circulationg pumps control output: double channels
signal input Water supplement control output: one channel
Heat exchanger control output: on channel
Anoloy output 0~20mA isolated output(corresponding to the conductivity): one
channel ( capacity load≤500Ω)
Communiction port RS-485 serial port: one channel

port 240x160 LCD screen with background light; 6 pieces of press key
Working
Temperature :0 ~ 60 ℃; Humidity :≤90% RH
environment
Power supply
AC 220V±10% 50Hz; Power consumption:≤10W

Demension
235×185×119mm

Installatin
Wall hanging.
SERIES OF CONDUCTIVITY METER
DCK-8550 Conductivity Controller
Main features:
DCK-8550 Midlevel Intelligent Network Model industrial on-line conductivity controller is a top
grade meter used for continuous measuring and controlling of industrial flow water quality.
Main Technical Specifications:
Conductivity measurement range:
0.1cm-1: 0.00μS -400.0μS,
-1
1.0cm : 0.00μS -4000μS,
10cm-1 : 0μS -40.00ms
Temperature measure range: 0~50℃
Accuracy: 1.0 %( FS)
Stability: ±2×10-3(FS)/24h
Auxiliary electrode: 0.1cm-1, 1.0cm-1 or
10.0cm-1 and with the match of PT100 three
wires platinum resistance thermometer sensor
Operation pressure of conductance cell: 0~0.5 MPa
Medium temperature: 5~50℃
Temperature compensation: automatic compensation, with 25℃ as standard
Cable composition: RVP+ coaxial cable 75-2 (double shielding)
Cable length: 5m or on agreement _ m
Display mode: the conductivity value、 temperature、 time and date、operating status and current mA
values on the LCD (Liquid Crystal Display) screen at the same time
LCD back-light brightness: 5 levels to be selected
4~20mA output: active or passive output, isolated, adjustable, reversible 4~20mA output
Alarm output mode: open collector/ set electrode, light isolated output: the maximum value 300mA,
the maximum value of up-pull voltage 24VDC (direct current), high/low alarm with adjustable of
return.
Maximum speed of frequency output: 400pulses/minute, used for driving adding medicine pump
Environmental Condition: temperature: 0~50℃ ; humidity: ≤85% RH
Temperature compensation components: PT100 three wires platinum resistance thermometer sensor
Power supply: DC24V (±4V)
Outline dimension: 96 × 96 × 103mm (height × width × depth)
Slot dimension for installation: 91 × 91mm (height × width) Installation: Jam-in
DCK-8520 Series of Double Channels Intelligent Network Conductivity
Controller

Main features:
The double channels conductivity
monitor/controller can measure the value of
inflow water conductivity, outflow water
conductivity, desalination, current water
temperature, optional display double channel
resistivity, double channel TDS. 128×64 matrix
LCD display, English menu display, flexible
rubber key-press with good hand feeling, and also
with water-proof function. It is widely used for
power factory, chemicals, pharmacy,
environmental protection, metallurgy, paper
making, food and water supply etc.

Main technical specifications:


The conductivity measure range of the inflow and outflow (double channels) water:
0.00~200.0μS/cm (0.1cm-1 electrode); 0.00~2000μS/cm (1.0cm-1 electrode);
0~20.00mS/cm (10.0cm-1 electrode);
Accuracy: 1.5 %( FS)
Stability: 1×10-3(FS)/24h;
Operation pressure of the conductance cell: 0~0.5MPa;
Media temperature: 5~50℃
Temperature compensation: calculate compensation according to mathematic model, with 25℃ as
standard condition;
Display Mode: double channels conductivity display, double channels resistivity display, double
channels TDS display, desalination, temperature, alarm state and current mA value etc. Values
displayed separately on LCD screen;
LCD backlight brightness: adjustable 5 grade, touchable point lightness;
4-20mA output: selectable between instrument mode and transmitter mode, isolated, transferable,
reversible;
Alarm output mode: relay output, high/low limit alarm with adjustable of returns;
Environmental conditions: temperature: 0~50℃; Humidity: ≤90%RH;
Power supply: DC 24V (±4V);
Outline dimensions: 96×96×103mm (height × width × depth);
Slot dimension for installation: 91×91mm (height × width)
Installation : Jam-in
DCK-7161 Conductivity +Temperature Double Windows Controller
Main features:
DCK-7161 conductivity instrument is an online measuring and control instrument for water quality
conductivity of industrial process, which combines the measurement of conductivity and fluid
temperature. Its functions include electrode
constant selection and input through keyboard,
temperature compensation factor setting, range
selection, conductivity over limit alarming and
control setting, etc. The instrument is widely used
in pharmacy, chemical industry, electronic
industry, food and beverage industry, etc. for
monitoring of pure water, especially for water
production monitoring of reverse osmosis system.
Main technical specifications
Measuring range: 0~20、0~200、0~2000μ
S/cm(1.0cm-1 electrode)
0~2、0~20、0~200μS/cm(0.1 cm-1 electrode)(Three steps of ranges, selected through keyboard)
Accuracy: 1.5%(FS)
Stability: ±2×10-3(FS)/24h
Operation pressure of conductance cell: 0~0.5Mpa
Medium temperature: 5~50℃
Automatic temperature compensation: calculate compensation according to mathematic model , with
25 ℃ as standard condition (when the temperature compensation factor is zero, there is no
temperature compensation for measurement)
Power supply: AC 220V±10% 50Hz Power consumption: ≤2W
Output current signal: isolated output 4~20mA, switchable between active and passive output
(ex-factory setting is active output)
Display mode: red LED digit double-window display, 3½ digits for conductivity, 3 digits for
temperature
Control output mode: ON/OFF relay output
Load capacity of the relay: AC230V/7A Max; AC115V/10A Max.
Environment conditions: temperature: 0~50℃;humidity: ≤85%RH
Electrode configured: 1.0cm-1 plastic electrode, 0.1cm-1 stainless steel electrode
Screw thread size: 1/2"NPT (pipe thread)
Cable structure: RVP+ coaxial cable 75-2 (double shielding)
Cable length: normal 5m or specified as ______m
Auxiliary printer:WDJ-4680 paperless recorder + printer
Dimension:96×96×130 mm ( height×width×depth)
Slot dimension for installation: 91×91 mm ( height×width)
Installation: Jam-in
DCK-7261 Double Channels Conductivity+Temperature Double Windows Controller
Features
Double electrodes and double channels conductivity
controller. With functions of jam-in microchip for
measure, calculating and display of multi parameters
(inflow water conductivity, outflow water conductivity,
desalinization and real time temperature).
Menu-driven operation, keyboard type setting and
modification of parameters (electrode constant check,
temperature compensation factor, conductivity over
limit alarm setting and signal output).
It is widely used in reverse osmosis system for
continuous measurement and analysis of inflow water,
outflow water, temperature, and desalinization ratio.
Main Technical Specifications
Measurement range: Inflow water measure range: 0~2000, 0~200μS/cm
Outflow water measure range:0~200, 0~20μS/cm
Auxiliary Electrode: Inflow water electrode constant: 1.0cm-1
Outflow water electrode constant: 0.1cm-1
Accuracy: 1.5 %( FS)
Stability: ± 2×10-3(FS)/24h
Medium temperature: 5~50℃
Medium pressure : 0~0.5 MPa
Thread dimension: 1/2 inch pipe thread
Temperature compensation: digital compensation with 25℃ as standard condition
Display mode: Red LED digit double windows Display, Conductivity: 3.5Bit, Temperature: 3 bit
Contact point mode: ON/OFF, 5A/250V AC
Digital communication: RS 485 data output.
Analog Signal: isolated 4-20 mA output analog quantity output (meter mode). The in-flow water,
outflow water channels could be selected.
Controlling mode: Inflow water conductivity Hi/Lo limit alarm, ON/OFF relay output.
Outflow Water conductivity Hi/Lo limit alarm, ON/OFF relay output.
Backlash treatment:Conductivity Hi-limit alarm; without action backlash, prevention of critical
shake.
Auxiliary printer: WDJ-4680 paperless recorder + printer
Environment conditions: temperature: 0~50℃;humidity ≤85%RH
Power supply: AC 220V±10% 50Hz
Outline dimensions: 96×96×130mm (height × width × depth)
Slot dimension for installation: 91×91mm (height × width) Installation: Jam-in
DCK-4230/4231/4232/4332 Conductivity Meter
Main features:
DCK-4000 series conductivity meter is an
online measuring and control instrument
for water quality conductivity of industrial
process. It is widely used for reverse
osmosis, electrolysis, desalination of sea
water; recycle water and continuously
monitoring for various water treatment
equipment.

DCK-4000 Series comparison Table

Model 4-20mA Output mode Relay output Measurement range Range switch
DCK-4230 None-isolated Instrument mode No 0-20,0-200,0-2000 Manual
DCK-4231 No No Yes 0-20,0-200,0-2000 Manual and Automatic
DCK-4232 None-isolated Instrument mode Yes 0-20,0-200,0-2000 Manual and Automatic
Instrument and
DCK-4332 Isolated Yes 0-20,0-200,0-2000 Manual and Automatic
Transmitter mode
Main Technical Specifications
Conductivity Measuring range: 0~20、0~200、0~2000μS/cm(1.0cm-1 electrode)
0~200、0~2000μS/cm、0~20mS/cm (10.0cm-1 electrode)
(Three steps of ranges, selected through keyboard)
Temperature measuring range: 0~60℃
Accuracy: 1.5%(FS)
Stability: ±2×10-3(FS)/24h
Operation pressure of conductance cell: 0~0.5Mpa
Medium temperature: 5~50℃
Automatic temperature compensation: calculate compensation according to mathematic model , with
25 ℃ as standard condition (when the temperature compensation factor is zero, there is no
temperature compensation for measurement)
Power supply: AC 220V±10% 50Hz
Power consumption: ≤2W
Output current signal: isolated output 4~20mA, switchable between active and passive output
(ex-factory setting is active output)
Display mode: 3½ digits for conductivity, 3 digits for temperature
Contact capacity: 3A/250V AC (for resistive load)
Environment conditions: temperature: 0~50℃;humidity: ≤85%RH
Electrode configured: 1.0cm-1 plastic electrode
Screw thread size: 1/2"NPT (pipe thread)
Cable structure: RVP+ coaxial cable 75-2 (double shielding)
Cable length: normal 5m or specified as ______m
Outline dimensions:96×96×130 mm ( height×width×depth)
Slot dimension for installation: 91×91 mm ( height×width) Installation: Jam-in
DCK-3900 High-temperature Conductivity/Resistivity Double Windows
Controller
Performance features
Temperature + conductivity + resistivity controller. Electrode consistent check can be met by jam-in
Microchip. Conductivity/resistivity can be
displayed optionally.
Conductivity/resistivity and
temperature over limit alarm can be set
optionally. Conductivity/resistivity can
be displayed at the same time with
double-line LED digital canal. With
function of digit calculating
temperature compensation, it can preset
and modify compensation parameters.
Conductivity/resistivity at temperature
of 25℃ or 90℃ can be displayed
optionally. It is with features of
stability of high temperature and reliable long time operation.
Main Technical Specifications
Measuring range: Conductivity : 0~20μS/cm Resistivity : 0.05~18.25 MΩ·cm
Accuracy: 1.0%(FS)
Stability: ±2×10-3(FS)/24h
Auxiliary electrode: 0.1cm-1 High temperature sanitation 316 L stainless steel
Medium temperature: 70~150℃
Temperature compensation : Automatic temperature compensation: calculate compensation with 90℃
as standard condition
Power supply: AC 220V±10% 50Hz
Power consumption: ≤4W
Data connection port: RS485 port, Modbus agreement
Output current signal: isolated output 4~20mA, switchable between active and passive output
Maximum load impedance: 500Ω Max@ 24V DC
Display mode: Red LED digit double-window display
Contact capacity: 5A/250V AC (for resistive load)
Environment conditions: temperature: 0~50℃;humidity: ≤85%RH
Screw thread size: 1/2"NPT (pipe thread)
Cable structure: RVP+ coaxial cable 75-2 (double shielding)
Cable length: normal 5m or specified as ______m
working pressure of conductance cel:0~1.0MPa
Control output: ON/OFF double channels relay output.
Load capacity of the relay: AC230V/7A Max; AC115V/10A Max.
Auxiliary printer: WDJ-4680 paperless recorder+ printer
Dimensions:96 × 96 × 130mm (height × width × depth)
Slot dimensions for installation:91 × 91mm (height × width) Installation: Jam-in
CM-230(330)X Series Intelligent Conductivity Meter

Performance features
CM-230(330)X series intelligent on-line conductivity meter, it is the upgrade substitute meter of
CM230、CM-230SX 、330、
240、340.
It has keyboard setting electrode
constant , high、low limit alarm,
transferable 4 ~ 20mA current
signal output , checking the
media temperature、μS/cm and
ppm (TDS)conversion through
the switching keys,automatic range conversion,three types of constant to be chosen
(0.1cm-1、1.0 cm-1、10.0 cm-1),larger measurement range.
It has ultra steady measurement collecting,large temperature range、low excursion design,can
switch conductivity/ temperature/TDS under the measurement condition,can give an alarm when the
water quality is over standard,high brightness back-light LCD display.
It is used for on-line monitoring and controlling of reverse osmosis 、electrodialysis、ion exchange
producing water system、cooling water control system and industrial water..
Model and performance function:
Non-isolated Automatic Hi/Lo
4mA signal measurement Hi-limited limited Units of the Probe
Function/model output range alarm setting alarm setting measurement Constant

CM-230A ● ● ● ●
CM-230C ● ● ● ●
CM-230D ● ● ● ● ●
CM-330C ● ● ● ●
Main technical specification:
Measurement range:
Conductivity: 0~19.99 0~199.9μS/cm (0.1cm-1 electrode)
0~19.99 0~199.9、0~1999μS/cm (1.0 cm-1 electrode)
0~199.9μS/cm 0~1999μS/cm 0~19.99mS/cm (10cm-1 electrode)
Temperature: 0-50℃
Auxiliary electrode:
1.00cm-1 plastic platinum gold electrode,1/2″(1/2 inch)pipe screw connection;
1.00cm-1 stainless steel electrode,1/2″(1/2 inch)pipe screw connection;
10.0 cm-1 Teflon platinum electrode,3/4″(3/4 inch)pipe screw connection;
The length of the cable:5m as ex work standard figure or according to the user’s specification;
Medium pressure:0~0.5MPa;
Medium temperature:0~50℃;
Component of temperature compensation:NTC;
Display mode:conductivity:3.5-bits LCD Digit display,temperature: 3- bits Digit display;
Accuracy:1.5%(FS)
Stability:±2×10-3(FS)/24h;
Temperature compensation : Digit calculating compensation , with 25 ℃ as the reference
temperature;
Output signal :non- isolated,transferable 4~20mAcurrent;
Maximum load impedance :300Ω Max@ DC 9V ;
Relay load capacity:AC 230V/5A Max (without electromagnetic induction);
Output control model:ON/OFF two contacts relay output;
Power supply :AC 220V±10%,50Hz;
Power consumption:2W
Environment conditions:Temperature:0~50℃; Humidity:≤85%RH;
Outline dimension:48×96×100mm(height×width×depth)
Slot dimension for installation:45×91mm(height×width)
Installation: Jam-in
CM-230 Conductivity Monitor
Performance features
This instrument is a panel instrument for
on-line monitoring of industrial process
conductivity. Range switch over and constant
check can both be freely set and adjusted
through the operation component on the rear
panel; unique signal collecting and processing
technology and special thick film circuit are
adopted to make measurement accurate and
operation stable; there are also other features such as linearzed data, automatic temperature
compensation, not subject to the length change of cable and maintenance-free. It’s an ideal auxiliary
instrument of various types of small pure water equipment.
Main technical specifications
Measurement range: 0~20 0~200 0~2000μS/cm
Accuracy 1.5% (FS)
Stability ±2 × 10-3 (FS) / 24h
Auxiliary electrode Plastic structure; constant: 1.0cm-1
Temperature compensation NTC
Medium temperature 5~50℃
Output signal Non-isolated 4-20mA signal output
Maximum load impedance 300Ω Max@ 24V DC, instrument mode
Thread dimension 1/2〃pipe thread
Medium pressure 0~0.5Mpa
Cable composition RVP + coaxial 75-2 double shielding
Cable length 5m or on other agreement (5~30m)
Temperature compensation Automatic compensation, with 25℃ as the reference temperature
Display Back light 3.5-bit LCD
Power supply AC 220V ±10% 50Hz
Power consumption ≤1W
Environment conditions Temperature: 5~50℃ ;Humidity: ≤85%RH
Dimensions 48 × 96 × 100mm (height × width × depth)
Slot dimensions for 45 × 91mm (height × width)
Installation Jam –in
CM-230SX Hi/Lo Limited Conductivity Controller
Performance features
This instrument is a panel instrument for
online monitoring of industrial process
conductivity. The measurement range and
constant has been set by original
manufacturer. It can be set alarm for high or
low limit of conductivity .It has automatic
temperature compensation with 25℃ as
reference temperature. It features stable
operation and accurate measurement. And it
is widely used in online monitoring of water quality for electrodialysis, reverse osmosis
system and common pure water producing system. It’s an ideal auxiliary instrument of various types
of small pure water equipment.
Main technical specifications
Measurement range: 0~20μS/cm,0~200μS/cm,0~2000μS/cm (Fixed range which has been set
by the manufacturer can not be changed by customers: So please indicate which measure range will
be needed before placing an order)
Accuracy:1.5% (FS)
Stability:±2 × 10-3(FS) / 24h
Auxiliary electrode: Plastic structure; constant: 1.0cm-1
Temperature compensation component: NTC
Medium temperature:5~50℃
Control output mode: ON/OFF relay output
Relay load capacity: AC 230V/7A Max ; AC 115V/10A Max
Thread dimension:1/2″pipe thread
Medium pressure:0~0.5Mpa
Cable composition: RVP + coaxial 75-2 double shielding
Cable length:5m or on other agreement (5~30m)
Temperature compensation: Automatic compensation, with 25℃ as the reference temperature
Display:3.5-bit LCD
Power supply: AC 220V ±10% 50Hz
Power consumption:≤1W
Environment conditions: Temperature: 5~50℃;Humidity: ≤85%RH
Dimensions:48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation:45 × 91mm (height × width)
Installation: Jam-in
CM-232 Double Channels Conductivity Monitor
Performance features
This instrument is a panel
instrument for on-line
monitoring of industrial
process conductivity.
Measurement range and
constant check have been
adjusted by manufacturer.
Easy installation and
operation, accurate
measurement and stable operation. There are also other features such as linearized data, automatic
temperature compensation, not subject to the length change of cable and maintenance-free. It’s an
ideal auxiliary instrument of various types of small pure water equipment.

Main technical specifications


Measurement range: Inflow water: 0~200μS/cm outflow water: 0~20μS/cm
Inflow water: 0~2000μS/cm outflow water: 0~200μS/cm

Accuracy 1.5% (FS)

Stability ±2 × 10-3 (FS) / 24h

Auxiliary electrode Plastic structure; constant: 1.0cm-1


316 L stainless steel constant: 0.1cm-1

Temperature compensation NTC


component

Medium temperature 5~50℃

Thread dimension 1/2〃pipe thread

Medium pressure 0~0.5Mpa; 0~1.0Mpa

Cable composition RVP+ coaxial 75-2 double shield

Cable length 5m or on other agreement(5~30m)

Temperature compensation Automatic compensation , with 25 ℃ as the reference


temperature
Display 3.5-bit LCD
Power supply AC 220V ±10% 50Hz
Power consumption ≤1W
Environment conditions Temperature: 5~50℃ ;Humidity: ≤85%RH
Dimensions 48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation 45 × 91mm (height × width)
Installation Jam-in
CMS-230 High Salinity Conductivity Monitor
Performance features
This instrument is a panel instrument for
on-line monitoring of industrial process
conductivity. Range switch over and
constant check can both be freely set and
adjusted through the operation component
on the rear panel; unique signal collecting
and processing technology and special thick
film circuit are adopted to make
measurement accurate and operation stable;
there are also other features such as
linearized data, automatic temperature compensation, not subject to the length change of cable and
maintenance-free. It’s an ideal auxiliary instrument of various types of small pure water equipment.

Main technical specifications


Measurement range: 0~20mS/cm (Note:1 mS/cm=1000μS/cm)
Accuracy:1.5% (FS)
Stability:±2 × 10-3 (FS) / 24h
Auxiliary electrode: Plastic structure; constant: 1.0cm-1
Temperature compensation component: NTC
Medium temperature:5~50℃
Output signal: Non-isolated 4-20mA signal output
Maximum load impedance:300Ω Max@ 24V DC, instrument mode
Thread dimension:1/2〃pipe thread
Medium pressure:0~0.5Mpa
Cable composition: RVP + coaxial 75-2 double shielding
Cable length:5m or on other agreement (5~30m)
Temperature compensation: Automatic compensation, with 25℃ as the reference temperature
Display: Back light 3.5-bit LCD
Power supply: AC 220V±10% 50Hz
Power consumption:≤1W
Environment conditions: Temperature: 0~50℃ ;Humidity: ≤85%RH
Dimensions:48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation:45 × 91mm (height × width)
Installation: Jam-in
:
TDS-230 Consistence Monitor
Performance features
This instrument is a panel instrument for
on-line monitoring of industrial process
consistence monitor. Range switch over and
constant check can both be freely set and
adjusted through the operation component
on the rear panel; unique signal collecting
and processing technology and special thick
film circuit are adopted to make
measurement accurate and operation stable;
there are also other features such as
linearized data, automatic temperature
compensation, not subject to the length change of cable and maintenance-free. It’s an ideal auxiliary
instrument of various types of small pure water equipment.

Main technical specifications


Measurement range: 0~20 0~200 0~2000ppm
Accuracy:1.5% (FS)
Stability:±2 × 10-3 (FS) / 24h
Auxiliary electrode: Plastic structure; constant: 1.0cm-1
Temperature compensation component: NTC
Medium temperature:5~50℃
Thread dimension:1/2〃pipe thread
Medium pressure:0~0.5Mpa
Cable composition: RVP + coaxial 75-2 double shielding
Cable length:5m or on other agreement (5~30m)
Temperature compensation: Automatic compensation, with 25℃ as the reference temperature
Display: Back light 3.5-bit LCD
Output signal: Non-isolated 4-20mA signal output
Maximum load impedance:300Ω Max@24V DC, instrument mode
Power supply: AC 220V±10% 50Hz
Power consumption:≤1W
Environment conditions Temperature: 5~50℃
Humidity: ≤85%RH
Dimensions:48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation:45 × 91mm (height × width)
Installation: Jam-in
CM-240 Conductivity Monitor

Performance features
This instrument is a panel instrument
for on-line monitoring of industrial
process conductivity. Range switch
over and constant check can both be
freely set and adjusted through the
operation component on the rear
panel; unique signal collecting and
processing technology and special
thick film circuit are adopted to
make measurement accurate and operation stable; there are also other features such as linearized data,
automatic temperature compensation, not subject to the length change of cable and maintenance-free.
It’s an ideal auxiliary instrument of various types of small pure water equipment.
Main technical specifications
Measurement range: 0~20 0~200 0~2000μS/cm
Accuracy:1.5% (FS)
Stability:±2 × 10-3 (FS) / 24h
Auxiliary electrode: Plastic structure; constant: 1.0cm-1
Temperature compensation component: NTC
Medium temperature:5~50℃
Output signal: Non-isolated 4-20mA signal output
Maximum load impedance:300Ω Max@ 24V DC, instrument mode
Thread dimension:1/2〃pipe thread
Medium pressure:0~0.5Mpa
Cable composition: RVP + coaxial 75-2 double shield
Cable length:5m or on other agreement (5~30m)
Temperature compensation: Automatic compensation, with 25℃ as the reference temperature
Display:3.5-bit Red LED
Power supply: AC 220V ±10% 50Hz
Power consumption:≤1W
Environment conditions: Temperature: 5~50℃ ;Humidity: ≤85%RH
Dimensions:48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation:45 × 91mm (height × width)
Installation: Jam-in
CM-330 Conductivity Controller
Performance features
This instrument is a panel instrument
for on-line monitoring of industrial
process conductivity. Range switch
over and constant check can both be
freely set and adjusted through the
operation component on the rear panel;
unique signal collecting and processing
technology and special thick film
circuit are adopted to make
measurement accurate and operation stable; there are also other features such as linearized data,
automatic temperature compensation, not subject to the length change of cable and maintenance-free.
It has control function, including setting of over limit of conductivity, and the outputs are control
contacts. It’s an ideal auxiliary instrument of various types of small pure water equipment.
Main technical specifications
Measurement range:0~20, 0~200, 0~2000 (μS/cm) optional
Accuracy:1.5% (FS)
Stability:±2 × 10-3 (FS) / 24h
Auxiliary electrode:1.0cm-1 plastic electrode
Temperature compensation component: NTC
Medium temperature:5~50℃
Thread dimension:1/2〃pipe thread
Medium pressure:0~0.5Mpa
Cable composition: RVP + coaxial 75-2 double shield
Cable length:5m or on other agreement (5~30m)
Temperature compensation: Automatic compensation, with 25℃ as the reference temperature
Display:3.5-bit LCD
Control output mode: ON/OFF relay output
Relay load capacity: AC 230V/7A Max ; AC115V/10A Max
Power supply: AC 220V ±10% 50Hz
Power consumption:≤1W
Environment conditions: Temperature: 0~50℃ ;Relative humidity: ≤85%
Dimensions:48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation:45 × 91mm (height × width)
Installation: Jam-in
CM-330D Conductivity Controller
Performance features
This instrument is a panel instrument for
on-line monitoring of industrial process
conductivity. Range switch over and
constant check can both be freely set and
adjusted through the operation component
on the rear panel; unique signal collecting
and processing technology and special thick
film circuit are adopted to make
measurement accurate and operation stable; there are also other features such as linearized data,
automatic temperature compensation, not subject to the length change of cable and maintenance-free.
It has control function, including setting of over limit of conductivity, and the outputs are control
contacts. It’s an ideal auxiliary instrument of various types of small pure water equipment.

Main technical specifications


Measurement range 0~20, 0~200, 0~2000 (μS/cm) optional

Accuracy 1.5% (FS)

Stability ±2 × 10-3 (FS) / 24h

Display mode Back light 3.5 LCD digital display

Auxiliary electrode 1.0cm-1 plastic electrode

Thread dimension 1/2〃pipe thread

Control output mode ON single contact relay output

Relay load capacity AC 230V/5A Max; AC115V/10A Max

Environment conditions Temperature: 0~50℃ ;Relative humidity: ≤85%


Temperature compensation Automatic compensation, with 25 ℃ as the reference
temperature
Power supply AC 220V ±10% 50Hz

Cable composition RVP + coaxial 75-2 double shielding


Operation pressure of 0~0.5MPa
conductance cell
Cable length 5m or on other agreement

Dimensions 48 × 96 × 100mm (height × width × depth)

Slot dimensions for installation 45 × 91mm (height × width)

Installation Jam-in
DDY-2327 Portable Conductivity Monitor
Performance features
This instrument is suitable for conductivity measurement of
outdoors. Multi-purpose software is adopted to make
measurement accurate and performance stable. It features
with such as floating digit, direct reading, and automatic
measurement range and temperature measurement.

Main technical specifications


Measurement range: 0~20μS/cm, 0~200μS/cm,
0~2000μS/cm (Measurement range switched over
automatically)
Temperature range:0~50℃

Conductivity accuracy:1.5% (FS)

Temperature accuracy:0.5℃

Stability:±2 × 10-3 (FS) / 24h

Auxiliary electrode: Plastic structure; constant: 1.0cm-1

Medium temperature:0~50℃

Display:3.5-bit LCD

Power supply: DC 9V battery

Weight: About 150g (batteries not included)


(1) Environment conditions Temperature: 0~50℃

(2) Humidity: ≤85%RH

(3) No strong electro-magnetic field interference except earth magnetic field

Dimensions:150 × 70 × 25mm

Temperature compensation factor No Temperature compensation and Temperature compensation


could be set, conductivity value under temperature compensation factor: 0-7%.

It is powered off automatically each time running 5 minutes.


SERIES OF RESISTIVITY METER
DRK-7361 Resistivity Controller
Features
DRK-7361 is an instrument for online monitoring
and controlling resistivity of industrial process
water quality. It is a combination of resistivity and
temperature measurement. With jam-in microchip it
has functions of electrode constant input, check,
setting of resistivity over limit alarm and control
through keyboard. It is widely used for industrial
online measuring and controlling of ultra-pure water,
high-pure water in pharmacy and electronic
industry.

Main Technical Specifications


Measurement range: 0~18.25MΩ·cm
Accuracy: 2.0 %( FS)
Stability: ±2×10-3(FS)/24h
Auxiliary Electrode: constant 0.05cm-1; sanitary 316L stainless steel titanium cylindrical electrode
Medium pressure: 0~0.5Mpa
Thread dimension: 1/2″pipe thread
Medium temperature: 5~50℃
Temperature compensation : Automatic compensation, with 25℃ as standard condition
Cable length: 10m or on other agreement _____m
Output signal: Isolated 4~20mA analog quantity output, (instrument mode).
Display mode: red LED digit double windows display, Resistivity: 3.5bit, Temperature: 3bit
Data communication: RS485 data connection port
With resistive load:500ΩMax@24V DC
Control output mode: ON/OFF relay output
Load capability of the relay: AC 230V/7A Max; AC 115V/10A Max
Auxiliary printer: WDJ-4680 paperless recorder + printer
Environment conditions: (1) temperature: 0~50℃ (2)humidity ≤85%RH
Power supply: AC 220V±10% 50Hz
Power spend: ≤4W
Dimensions:96×96×130mm (height × width × depth)
Slot dimension for installation: 91×91 mm ( height×width)
Installation: Jam-in
DRK-7461 Resistivity Controller

Features
DRK-7461 is an instrument for online monitoring and

controlling resistivity of Industrial process water quality.

With jam-in microchip it has functions of electrode

constant input, check, setting of resistivity high limit

alarm and control through keyboard .It is widely used for

comparing and monitoring the quality change before

treatment and after treatment of EDI and anion-cation

exchange bed.

Main Technical Specifications


Measurement range: 0~18.25MΩ·cm

Auxiliary Electrode constant: 0.05cm-1

Accuracy: 2.0 %( FS)

Stability: ±2×10-3(FS)/24h

Medium temperature: 5~50℃

Temperature compensation: automatic compensation with 25℃ as standard condition

Data communication: RS485 data connection port

Signal output: Analog signal 4~20mA (load characteristics :500Ω Max@24V DC)

Control output Mode: ON/OFF double relays output

Load capability of the relay: AC 230V/7A Max; AC 115V/10A Max

Alarm Mode: resistivity low limit alarm and setting of action backlash can avoid critical shake

Auxiliary printer: WDJ-4680 paperless recorder + printer

Environment conditions: temperature: 0~50℃;humidity ≤85%RH

Power supply: AC 220V±10% 50Hz

Outline dimensions: 96×96×130mm (height×width×depth)

Slot dimension for installation : 91×91mm (height×width)

Installation: Jam-in
DRK-7561 Resistivity Controller
Features
It is an instrument for online measuring and controlling
conductivity/resistivity of Industrial process water quality.
With jam-in microchip it has functions of electrode
constant input ,check ,setting of resistivity high limit
alarm and control through keyboard .It is widely used for
comparing and monitoring the quality change before
treatment and after treatment of EDI , anion-cation
exchange bed and two grade reverse osmosis.

Main Technical Specifications


Measurement range:
Resistivity : 0~18.25MΩ·cm Auxiliary electrode : 0.1 cm-1
Conductivity : 0~20μS/cm(conductivity) Auxiliary electrode: 0.05 cm -1
Accuracy: 1.5%(FS) (resistivity); 2.0 %( FS) (conductivity)
Stability: ±2×10-3(FS)/24h
Temperature compensation: automatic compensation with 25℃ as standard condition
Medium temperature: 5~50℃
Screw thread size: 1/2"NPT (pipe thread)
Medium pressure: 0~0.5Mpa
Cable structure: RVP+ coaxial cable 75-2 (double shielding)
Cable length: conductivity normal 5m or specified as ______m
Resistivity normal 10m or specified as ______m
Signal output: Analog signal 4~20mA (load characteristics :500Ω Max@24V DC), switchable
between active and passive output (ex-factory setting is active output)
Display: conductivity /resistiivity3.5 red LED, Temperature 3 red LED.
Control output Mode: ON/OFF double relays output
Environment conditions: temperature: 0~50℃ humidity ≤85%RH
Power supply: AC 220V±10% 50Hz
Power consumption: ≤4W
Load capacity of the relay:AC 230V/7A Max; AC115V/10A Max.
Auxiliary printer: WDJ-4680 paperless recorder + printer
Outline dimensions: 96×96×130mm (height×width×depth)
Slot dimension for installation : 91×91mm (height×width)
Installation: Jam-in
DRK-4000 Series of Resistivity Controller

Features
DRK-4000 series controllers are the kind of
intelligent industry on-line controllers. There is a
flush type CMOS chip inside the controller for
resistivity controlling, so the controller is rich of the
software function. The controller could be set and
controlled the Resistivity low-limited alarm; switch
over the value of conductivity and resistivity;
insulated transferable 4-20 MA current signal output;
work as controller / transformer; work with the PLC
/ servo system conveniently ; Connect with all the 4-20 MA current signal output
systems.
Due to the nice appearance and the friendly operation mode, the DRK-4000 controller
has special features.
The controller has different kinds of the functions, competitive price and excellent
performance; all these can meet the requirements of different level users.
The controller can widely used in the measurement of EDI, Ion exchange, Hi-pure water,
Ultra water…

Technical Specification
Measurement Range: Resistivity: 0~18.25MΩ·cm Conductivity: 0.050~2.0μS/cm
Accurate: 2.0 %( FS)
Stability: ±2×10-3(FS)/24h
Auxiliary Electrode: constant 0.05cm-1; sanitary 316L stainless steel titanium cylindrical
electrode
Medium temperature: 5~50℃
Temperature compensation : Automatic compensation, with 25℃ as standard condition
Display mode: LCD digit double windows display, Resistivity/Conductivity: 3.5bit,
(the conductivity value could be display transiently)
Contact point mode: ON/OFF, 5A/250V AC
Environment conditions: (1) temperature: 0~50℃ (2)humidity ≤85%RH
Power supply: AC 220V±10% 50Hz
Power spend: ≤3W
Outline dimensions: 96×96×130mm (height × width × depth)
Instrument panel hole: 92×92mm (height × width)
Installation: Jam-in
Technical Sheet

4-20mA signal output (Load characteristic)


Function Switch signal
Meter mode Transformer output
Type
Isolate output output

DRK-4220 ● ● ● ●

DRK-4220A ● ● ●

DRK-4220C ●
RM-220/320 CRM-420 CRC-520 Resistivity Monitor/Controller
Performance features
The instruments of this series are on-line panel-mode

high-purity water resistivity/conductivity instruments,

which is suitable for on-line water quality monitoring of

EDI and high-purity water produced by anion-cation

mixing and exchanging bed. It’s measurement accuracy

is high since it adopts unique signal collection and multi

automatic temperature compensation technologies; 316L stainless steel electrode is configured to

ensure long term and stable operation. It also has some optional functions such as control, alarm,

4~20mA electric current loop output, etc; its high-end

product adopts high performance SCM as processing

core for more stability and accuracy. It also has the

function of switching display between specific

conductance/resistance.

Type and basic function

Type
Option RM-220 RM-320 CRM-420 CRC-520
function

Control, alarm × √ × √

4-20mA output √ × √ ×
Switching display between
× × √ √
conductance/resistance

Main technical specifications


Measurement range: 0~18.2MΩ·cm
Accuracy: 2.0 %( FS)
Stability: ±2×10-3(FS)/24h
Supporting electrode parameters:
Material: sanitary level 316L stainless steel
Electrode constant: 0.05 cm-1
Output signal: 1) Switch quantity (a group
of switching contact)
2) Analog quantity 4 ~ 20mA (load
characteristics 0-300Ω)
Temperature compensation: automatic
compensation with 25℃ as standard condition
Medium temperature: 5~50℃
Thread size: 1/2" pipe thread
Medium pressure: 0~0.5MPa
Cable structure: RVP+ coaxial cable 75-2 (double
shielding)
Cable length: 10m or specified as ______m
Display mode: LCD display (ordinary
type/background-light type)
Power supply: AC 220V±10% 50Hz
Power consumption: ≤1W
Environment conditions: (1) temperature: 0~50℃ (2)humidity ≤85%RH
Outline dimensions: 48×96×100mm (height×width×depth)
Instrument panel hole: 45×91mm (height×width)
Installation: Jam-in
REVERSE OSMOSIS PROGRAM CONTROLLER
ROC-8221A Reverse Osmosis Controller
Performance Features
ROC-8221A is a combined control instrument of
a single-stage reverse osmosis controller and
double-channel on-line conductivity instrument.
It can perform the operational test, status control
and the on-line monitoring of inlet water,
producing water, the temperature of the water and
desalinization ratio of the water quality
conductivity, displayed by LCD large screen. The
interface is friendly, menu-driven operation is
used; multiple group parameter can be set and
modified. The requirement of automatic
operation of the multiple controlling ways of the
reverse osmosis system can be met.

Main Technical Indexes:


Reverse osmosis collection point:
Raw water tank high level, raw water tank low level, low pressure alarm, high pressure alarm, pure
water tank high level, pure water low level, pretreatment backflush chain;
Reverse osmosis control point: inflow valve, low pressure pump, high pressure pump, flushing valve,
conductivity over limit let valve
Collect input signal mode: direct current power supply, pull electrical digit, all terminals are isolated .
Conductivity Measurement Range:
1) inflow water 0~2000 μS/cm
2)Outflow water 0~20.00;0~200.0μS /cm (switched automatically)
Accuracy: 1.5 level
Auxiliary electrode: 1.0 cm-1
Working pressure of conduct cell: 0~0.5 MPa
Automatic temperature compensation:1~49°C
Effective distance:≤30m (standard 5 m ,or ordered ahead)
Displaying mode: LCD 128×64 backlight.
Load capability of the relay: AC 250V/3A Max
Power consumption: ≤3W
Power supply : DC24V (±4V)
Application environment : temperature 0~50 ℃; humidity ≤85%RH
Outline dimension:96×96×103mm (height×width×depth)
Slot dimension for installation: 91×91mm (height×width)
Installation: Jam-in
ROC-8221 Reverse Osmosis Controller
Performance Features
This instrument is a combined control instrument
of a single-grade reverse osmosis controller and
double-channel on-line conductivity instrument.
It can perform the operational test, status control
and the on-line monitoring of inflow water,
producing water, the temperature of the water and
desalinization ratio of the water quality
conductivity, displayed by LCD large screen. The
meter is easy to operate and menu-driven
operation is used; multiple group parameters can
be set and modified. The requirement of
automatic operation of the multiple controlling ways of the reverse osmosis system can be met.

Main Technology Index


Reverse osmosis collection point:
Raw water tank high level, raw water tank low level, low pressure alarm, high pressure alarm, pure
water tank high level, pure water low level, pretreatment backflush chain;
Reverse osmosis control point: inflow valve, low pressure pump, high pressure pump, flushing valve,
conductivity over limit let valve
Collect input signal mode: direct current power supply, pull electrical digit, all terminals are isolated.
Measurement range : inflow water 0~2000 μS/cm
outflow water 0~20、0~200μS/cm(switched automatically)
Accuracy:1.5level
Matching electrode: 1.0 cm-1
Working pressure of conduct cell:0~0.5 MPa
Automatic temperature compensation:1~49°C
Measuring distance:≤30m (standard 5 m ,or ordered ahead)
Displaying mode: LCD 128×64 backlight ,displaying in English
Load capacity of the relay: AC 250V/3A Max
Power consumption : ≤3W
Power supply :AC 220v ± 10% 50 HZ
Application environment : temperature 0~50 ℃; humidity ≤85%RH
Outline dimension: 96×96×130mm( height×width×depth)
Slot dimension for Installation :91×91 mm(height×width)
Installation : Jam-in
ROC-HY Reverse Osmosis Controller Operation Manual
Performance Features
The instrument is a combination

controller of reverse osmosis and online

conductivity/resistivity meter. It can perform

the operation test of system, state

control and online monitoring of

conductivity/resistivity value(combination of PLC

and conductivity/resistivity meter). ROC-HY is

widely used in the one stage of RO system for

automatic management of RO+DI produce water ; the

management of Lab ultra water system.

Main Technology Index

Reverse Osmosis collection point: Raw water no water protection, High pressure full water
protection,Operation reposition.
Reverse Osmosis control point: High pressure pump, Cycle pump, Flush valve, RO outlet
valve,Disinfection valve, Disinfection discharge valve, DI pure water outlet valve, Internal cycle
valve.
Power supply: DC24V (a power switch should be installed before designing the shell)
Power consumption: ≤7.2W
Environmental condition: 1) temperature: 0~60℃; 2) humidity: ≤ 85% RH.
Accuracy: 1.5 level
Output contact capacity load: 5A/250V AC 3A/24V DC
Updating rate of collecting result: ≤1sec/per time
Working pressure of conductance cell: 0~0.2Mpa
Automatic temperature compensation: 1~49℃
Interface mode: LCD display, English/sign display, touch key
Measurement range
TDS1 Raw water conductivity : 0-1000 ppm (auxiliary electrode 1.0 cm-1 )
TDS2 RO produce water conductivity: 0-100 ppm(auxiliary electrode 1.0cm-1)
DI produce water resistivity: 0-18.2 MΩ·cm (auxiliary electrode 0.05cm-1)
Return when over-time limit key. Under normal operation, not in the main interface, if there is no
any key were pressed within 2 minutes, it will come back to the main menu automatically .
Outline dimension: 90 × 150 × 46mm (height × width × depth)
Slot dimension: 57 × 106mm (height × width)
Installation: Panel
ROC-4313 Two stage reverse

osmosis conductivity controller

Performance Features
The instrument is combination of two stage
reverse osmosis controller and on-line
conductivity monitor. It is a special-purpose
measurement and control system. This system
has the functions of automatic test, operation
test, status control, display, letter hint, indicating light display etc. The controller
aggregates all the advantages of PLC controller and the meter for measuring water quality.
Main technical indexes
Raw water tank level, middle tank level, no water
protection, handle/automatic control, first stage
Reverse osmosis collecting point pressurization pump low/high pressure protection, second
stage pressurization pump high pressure protection, and so
on.
direct current power supply, pull electrical digit, all
Collecting input signal
terminals are isolated .
feed water pump, first-grade pressurization pump,
second-grade pressurization pump, inlet water valve,
Reverse osmosis controlling point
pretreatment valve, flushing valve, first-grade over-limit
outflow valve, second-grade over-limit outflow valve.
raw water conductivity collect ,first-stage outlet water
Measuring collection point conductivity collect, and second-stage outlet water as well
as temperature collection .
Raw water conductivity 0 ~ 20mS/cm 、 0 ~
2000μS/cm(match 10cm-1 or 1.0cm-1 electrode) first-stage
Measuring range reverse osmosis conductivity 0~200μS/cm(match 1.0 cm-1
electrode) second-stage reverse osmosis conductivity 0~
20μS/cm(match 0.1cm-1 electrode)
Power supply voltage 24V DC (switch should be installed outside when designing)
Accuracy 1.5 level
Output control mode ON single contactor output
Load capacity of output contact 5A/250V AC 3A/24V DC
Rate of renewal of connecting ≤1second\time
Operation pressure of conductance 0~0.5Mpa
Temperature compensation automatic temperature with 25℃ as reference temperature
Outline dimensions 130×180×60mm(height ×width ×depth)
Slot dimension for installation 122×172mm (height× width)
Installation control plate panel
ROC-3313 Reverse Osmosis Controller
Performance Features
The instrument is a combined control
instrument of a reverse osmosis controller and
an on-line conductivity instrument. It can
perform the operation test, status control and
on-line monitoring of water quality
conductivity (combining PLC controller and
conductivity meter). It takes multiple
anti-interference measures, adopts unique
process flow and graphical control panel with
LED indicator lamp embedded, the interface is
friendly; menu-driven operation is used, multiple groups of parameters can be set and modified, the
requirements of automatic operation are met.

Main technical specifications:


Reverse Osmosis collect point: raw water no water protection, low pressure protection, high
pressure protection, pure water tank high level protection, exterior operation, operation reposition
Reverse osmosis control point: raw water pump, high pressure pump, inflow valve, flush valve,
conductivity over limit let valve
Collecting input signal: direct current power supply, pull electrical digit, all terminals are isolated.
Power voltage: AC 220V±15% 50Hz Power consumption: ≤3W
Environment conditions: 1) temperature: 0~50℃; 2) humidity: ≤85%RH
Measuring range: 0~200μS /cm accuracy: 1.5 level
Controlling output mode: ON single contact relay output
Resistivity load impedance: AC 250V/3A Max.
Operation pressure of conductance cell: 0~0.5Mpa
Medium temperature:5~50℃
Temperature compensation: automatic temperature with 25℃ as reference temperature
Distance of measuring range: less than 30m (the ex-factory configuration of electrode cable is 5m
unless there is a special agreement)
Display mode: 3 1/2-digit LED digital display
Electrode selected: 1.0cm-1
Outline dimensions: 130×80×60mm (height×width×depth)
Slot dimension for installation: 122×172mm (height×width) Installation: Jam-in
ROC-2313 Reverse Osmosis Controller
Performance Features
The instrument is a combined control instrument of
a reverse osmosis controller and an on-line
conductivity instrument. It can perform the
operation test, status control and on-line monitoring
of water quality conductivity (combining PLC
controller and conductivity meter). It takes multiple
anti-interference measures, adopts unique process
flow and graphical control panel with LED
indicator lamp embedded, the interface is friendly;
menu-driven operation is used, multiple groups of
parameters can be set and modified, the
requirements of automatic operation are met.

Main technical specifications:


Reverse Osmosis collect point: raw water no water protection, low pressure protection, high
pressure protection, pure water tank high level protection, exterior operation, operation reposition
Reverse osmosis control point: raw water pump, high pressure pump, inflow valve, flush valve,
conductivity over limit let valve
Collecting input signal: direct current power supply, pull electrical digit, all terminals are isolated .
Power voltage: AC 220V±15% 50Hz Power consumption: ≤3W
Environment conditions: 1) temperature: 0~50℃; 2) humidity: ≤85%RH
Measuring range: 0~20μS /cm,0~200μS /cm,0~2000μS /cm (Fixed range which has been set by
the manufacturer can not be changed by customers: So please indicate which measure range will be
needed before placing an order. The ex-factory standard is 0-200μS /cm without prior indication.)
Note: 0~2000μS /cm is suitable for the equipment with conductivity of the outflow water 100~2000μS
/cm, with conductivity lower than 100μS /cm, measure range 0~200μS /cm or 0~20μS /cm should
be selected.
Accuracy: 1.5 levels
Controlling output mode: ON single contact relay output
Resistivity load impedance: AC 250V/3A Max.
Operation pressure of conductance cell: 0~0.5Mpa
Medium temperature:5~50℃
Temperature compensation: automatic temperature with 25℃ as reference temperature
Distance of measuring range: less than 30m (the ex-factory configuration of electrode cable is 5m unless
there is a special agreement)
Display mode: 3 1/2-digit LED digital display
Electrode selected: 1.0cm 1
-

Outline dimensions: 96×96×130mm (height×width×depth)


Meter board hole: 91×91mm (height×width) Installation: Jam-in
RO-2003 Reverse Osmosis Controller
Performance Features
RO-2003 controller combines the
typical operation modes of various
medium and small reverse osmosis
systems, adopts high-performance
computer chip and takes multiple
reliability measures, the technology
is mature and operation reliable; the
control panel visually displays the
operation status of the system by
visual flow chart with LED
indication lamp embedded. RO controller operates in a “five-in-four-out” way.

Main Technical Specifications


Reverse osmosis collect point: five in; no water protection, low pressure protection, high pressure
protection, water level protection, exterior operation.
Reverse osmosis control point: four out; raw water pump, high pressure pump, inflow valve, flush
valve
Collecting input signal: direct current power supply, pull electrical digit, all terminals are isolated .
Power voltage: AC 220V±15% 50Hz
Power consumption: ≤2W
Environment conditions: 1) temperature: 0~50℃;2) Humidity: ≤85%RH
Controlling output mode: ON single contact relay output
Resistivity load impedance: AC 250V/3A Max.
Outline dimensions: 48×96×100mm(height×width×depth)
Hole dimension: 45×91mm(height×width)
Installation: Jam-in
FLOW METER
WLG-8350 Series of Intelligent Network Flow Meter of Turbo Type
Model and Function

Function 2 channels
U disk Communication
Pulse input 4-20mA output OC door
connection connection
Model output
WLG-8350 ● ● ●
WLG-8351 ● ● ● ●
WLG-8352 ● ● ● ●
WLG-8353 ● ● ● ● ●

Input
Instantaneous value range: -9999~9999 radix point position could be set
Cumulation value range: 0~99999999
radix point position could be set
Resolution: 1/20000 Instantaneous value
Input signal type: pulse
Pulse: 0.1~150 KHz
Basic error: Less than ±0.2%F.S
Controlling period of measuring: 0.2
second
Record
Record capacity:4MB
Record interval:1second ~59 minutes 59 seconds could be selected. Cycle record or full record
suspends could be chose.
Record time:The computational formula between the record time and record interval :
Record days = (record capacity × record interval )/(24×3600)
72 hours is the shortest time record; 29 years is the longest time record.
Record content: instantaneous value
Alarm
Alarm output: instantaneous flow Hi-lo limited alarm mode and cumulative volume preset output.

OC door output ,voltage less than 30V, current less than 50mA
Transmit
isolated output
4mA~20mA,0mA~10mA,0mA~20mA DC current output, could be selected by setting . The
resistivity load is more than 600Ω. DC current output, select through setting. Load capacity should
larger than 600Ω

Output resolution:1/4000,error less than±0.5% F.S


Communication connection
isolated

RS485 domain communication

Instrument address : 0~99 ,which could be set


Communication rate: 2400、4800、9600、19200 could be selected by setting. It is should be note when
book the meter < 2400
There is a put-off when the meter reply the commend from the computer. The instrument will send the
relevant delay reply of the data when it received the order from the computer:
Be based on the “#” as the order of the rule, the delay reply <500μs ;other delay reply <100ms .

Auxiliary test software, and supply the Technical Support


Power supply of the transmitter
Normal power supply:power supply for the transmitter. The error of Output value is ±5% than the
standard value. The load is > 50mA
Power supply
24V DC,power consumption less than 10VA
PH/ORP METER
pH/ORP-8150 Series of Single/Double Channels Intelligent pH and
ORP Meter

Performance Features:
pH/ORP-8150 is a single/double channels pH/ORP meter, the
pH/ORP value of channel 1 or 2 can be displayed by single
channel, double-channel parameters can be also displayed
Simultaneously; Main parameters, temperature and mA
output value could be displayed on the screen synchronously,
the temperature compensation can be set as manual or
automatic mode.
This product is widely used for chemicals, pharmacy,
environmental protection, metallurgy, power factory, paper
making, food and water supply etc.

Main technical specifications:


Measure range: pH: 0~14pH;ORP: -1999mV ~ +1999mV
Temperature: 0~99.9℃
Resolution: pH: 0.01pH, mV: 1mV, T: 0.1℃;
Accuracy: pH: ±0.1pH, mV: ±0.5mV, T: ±1℃
Stability: ≤0.05pH/24h, ≤0.2℃/24h, ≤0.03mA/24h;
Automatic/Manual temperature compensation range:
0~99.9℃; Automatic three point calibration function;
Standard pH solution: 4.01, 6.86, 9.18;
Input resistivity resistance: larger than 1.5×1012;
The pressure resistance of the electrode: 0~0.6MPa
Control range: pH: 0.00~14.00; ORP: -1999~+1999mV
Power supply: DC 24V (±4V);
Environmental condition: temperature: 0~50℃;
Humidity: ≤85%RH;
Outline dimension: 96×96×103mm (height × width × depth);
Slot dimension for installation: 91×91mm (height × width)
Installation Jam-in
pH/ORP-8571 pH-meter/oxidation-reduction Potential Controller
Performance Features:
pH/ORP-8571 is on-line intelligent industrial pH (ORP) controller. It is suitable for online monitoring
of pH/ORP in water treatment, electronic power, chemical industry, pharmacy, environment protection,
breeding industry, and so on.

Main Technical Specifications

0~14 pH
pH measurement range

resolution 0.01 pH

accuracy ± 0.05 pH

measurement range -1999mV~+1999mV


ORP
resolution ± 1 mV

accuracy ± 2 mV

measurement range 0~99.9℃

TEMPERATURE resolution 0.1℃

accuracy ± 0.1℃
Display mode: with backlight 128×64
Control output: high limit, low limit double
lattice LCD display
rode ON/OFF double contact point output.
The range of automatic temperature
Capacity of contact point: AC230V/5A Max;
compensation: 0~99.9℃
AC 115V/10A Max
Stability: pH≤0.05pH/24H, ORP≤2mV/24h,
Communication: RS485 output
T≤0.2℃/24h
4~20mA current output: isolated, transferable,
≤0.03mA/24h
reverse, optional meter/transmitter output.
Identify automatically pH buffer and three
The maximum load impedance: 500 Ω
point calibration.
Max@24V DC
pH standard liquid: 4.01, 6.86, 9.18.
Power supply: AC 220V±10% 50Hz
ORP standard liquid: any
Environment conditions: humidity: ≤
Input impedance: >1.5×1012
85%/RH; no strong electro-magnetic field
Electrode pressure resistance: 0~0.6 MPa
interference except earth magnetic field
Measuring distance: ≤ 20m(standard
Outline dimensions: 96×96×130mm (height
configuration for electrode cable:5m).Please
×width×depth)
use pH transducer for overlong range.
Slot dimension for installation: 91×91mm
Control range: 0~14pH ; -1999mV~+1999
Installation: Jam-in
mV
pH/ORP-4571 pH/ORP Controller

Performance Features:
pH/ORP-4571 is on-line intelligent industrial pH (ORP)
controller. The instrument is suitable for online monitoring of
pH/ORP in water treatment, electronic power, chemical
industry, pharmacy, environment protection, breeding industry,
and so on.

Main technical indexes

— Control range: 0~14pH ;


measurement range 0~14 pH
-1999mV~+1999 mV
pH resolution 0.01 pH
— The mode of control
accuracy ±0.1 pH output: high limit, low

measurement range -1999mV ~ +1999mV


limit double rode
ON/OFF double contact
ORP resolution ±1mV
point output.
accuracy ±5mV — Capacity of contact
point: AC230V/5A Max;
measurement range 0~99.9℃
AC 115V/10A Max
TEMPERATURE resolution 0.1℃ — 4~20mA current output:
accuracy ±1℃ isolated, transferable,
reverse, optional
— Display: LCD.
meter/transmitter output.
— Automatic temperature compensation:
— Circular reisitivity: 500ΩMax@24V DC
0~99.9ºC.
— Power supply: AC 220V±10% 50Hz
— Stability : pH ≤ 0.05PH/24h ; ORP ≤
— Environment conditions: humidity: ≤
2mV/24h,T≤0.2℃/24h,≤0.03mA/24h。
85%/RH; no strong electro-magnetic field
— Identify automatically pH buffer and three
interference except earth magnetic field
point calibration. (Details in item
— Control mode: Relay control
5-calibration)
— Load capacity of the relay:AC230V/5A
— pH standard liquid: 4.01, 6.86, 9.18
Max; AC115V/10A Max
— ORP standard liquid: any
— Displaying:pH/ mV /temperature value
— Input impedance: >1.5×1012
— Searching: the Hi/Lo limited
— Electrode pressure resistance: 0~0.6 MPa
measurement range, the error marks
— Measuring distance: ≤ 20m (standard
— Outline dimensions: 96×96×120mm
configuration for electrode cable: 10m).
(height× width ×depth)
Please use pH transducer for overlong
— Instrument panel hole: 91×91mm
range.
— Installation: Jam-in
pH-4672 PID Intelligent Adjustment Controller
Performance Features:
pH-4672 is a kind of precision instrument with microcomputer controlling. The instrument has many
Technical features: the green color LCD screen with big character LCD display with backlight; the
instrument‘s measurement date could be set through
the menu and the data is accurate ; the instrument
can anti-jamming ,all digital operation;when the
instrument work with the dosing pump, the
operation system can be dosing automatically
which avoid the mistake of manual dosing.

Transferable, reversible, selectable between active


and passive mode, photoelectric isolated 4-20mA
output; identify the pH solution , three points
calibration; automatic temperature compensation.

Be used in the measurement and PID calibration for


the water treatment ﹑power﹑chemistry﹑medicine
making﹑environment –protection …

Main Technical Specification


— Measurement range: pH : 0-14 pH Temperature: 0- 99.9 ℃
— Resolution : pH:0.01 pH Temperature: 0.1 ℃
— Accurate: pH: ±0.1 pH Temperature: ±0.1 ℃
— Display : LCD big character display with backlight
— Automatic temperature compensation : 0-99.9 ℃
— Stability: ≤0.05 Ph/24 h ≤ 0.2 ℃/24h ≤ 0.03Ma /24h
— Automatic Three-point adjustment
— Standard Ph solution :4.01 6.86 9.18
— Input resistivity load: more than 1.5×1012
— Control range :pH 0-14
— The fastest rate of Frequency output : 400 pulse/minute ,used in driving the metering
pump
— Power supply: :AC 220V ± 10 % 50 HZ
— Environment conditions: temperature: 0-50 ℃ humidity: ≤85%/RH;
— Outline dimensions: 96×96×130mm (height×width×depth)
— instrument panel hole: 91×91mm(height×depth)
— Installation mode: jam-in
pH/ORP-6241 pH/ORP Meter

Performance Features:
pH/ORP-6241 controller is an industrial on-line analysis and monitoring instrument, with 51 series
Single Chip Microcomputer (SCM) and
CMOS interface chip adopted. It’s with various
software functions, and has such features as
easy installation and operation, strong
anti-interference capability and little amount of
maintenance work. High-accuracy temperature
compensation is also adopted. The pH -6241 is
suitable for environmental protection and
on-line measurement; the ORP-6241 is widely
used in OPR measurement of Water treatment,
electronics industry, pharmacy, chemical,
environment-protection…

Main Technical Specifications


pH measurement range : 0~14 pH ORP measurement range : -1000~+1000mV
pH resolution: 0.01 pH ORP resolution: 1mV
pH accuracy: 0.1 pH ORP accuracy ±1mV
Electrode pressure resistance: 0~0.6Mpa
Power supply: AC 220V±10% 50Hz
Distance limit of measurement: ≤40m (standard configuration for electrode cable: 10m). Please use
pH transducer for overlong range.
Contact capacity: 3A(240V AC)
Temperature of measured solution: 0~80℃
Environment conditions: humidity: ≤85%/RH; no strong electro-magnetic field interference except
earth magnetic field
Manual temperature compensation: 0~99℃
Stability: -1000-1000mV
In-put Impedance: ≥ 1×1012Ω
Output Signal: Isolated and transferable 4~20 mA current output.
The maximum load impedance: 500ΩMax@24V DC
Control output mode: ON single contact relay output
Load capacity of the relay:AC230V/5A Max; AC115V/10A Max
Outline dimensions: 96×96×130mm (height×width×depth)
Slot dimension for installation: 91×91mm (height × width)
Installation: Jam-in
pH-650 pH Controller
Performance Features:
pH-650 controller is an industrial on-line
analysis and monitoring instrument. The
instrument is suitable for online monitoring of
pH/ORP in water treatment, electronic power,
chemical industry, pharmacy, environment
protection, breeding industry, and so on.

Main Technical Specifications


pH measurement range: 0~14 pH
Resolution: 0.01 pH
Accuracy : ±0.1 pH
Electrode pressure resistance: 0~0.6Mpa
Power supply: AC 220V±10% 50Hz
Distance limit of measurement: ≤20m (standard configuration for electrode cable: 10m). Please use
pH transmitter for overlong range.
Contact capacity: 3A(220V AC)
Temperature of measured solution: 0~80℃
Environment conditions: humidity: ≤85%/RH; no strong electro-magnetic field interference except
earth magnetic field
Manual temperature compensation: 0~99℃
Output signal : non-isolated 4~20 mA
Manual compensation : 0~99℃
Display: 3.5 bit LCD
With resistive load:300ΩMax@24V DC
Control output: ON single contact double relays output
Relay load capacity:AC 230V/5A Max; AC115V/ 10A Max
Auxiliary: Plastic-shell double combination electrode.
Outline dimensions: 48×96×100mm (height×width×depth)
Slot dimension for installation : 45×91mm
Installation mode: Jam-in
ORP-651 Oxidation-reduction Potential controller
Performance Features:
We really appreciate your selection of
ORP-651 controller. It is an industrial
on-line analysis and monitoring instrument.
It’s with various software functions, and has
such features as easy installation and
operation, strong anti-interference capability
and little amount of maintenance work.

Main Technical Specifications


ORP measurement range: ±1000mV
Resolution: ±1mV
Accuracy: ±0.1 mV
Electrode pressure resistance: 0~0.6Mpa
Power supply: AC 220V±10% 50Hz
Distance limit of measurement: ≤40m (standard configuration for electrode cable: 10m). Please use
ORP transmitter for overlong range.
Temperature of measured solution: 0~80℃
Environment conditions: humidity: ≤85%/RH; no strong electro-magnetic field interference except
earth magnetic field
Display: 3.5 bit LCD
Signal: Non-isolated 4~20mA current.
With resistive load:300ΩMax@24V DC
Control output Mode: ON/OFF double relays output
Relay load capacity:AC 230V/5A Max; AC115V/ 7A Max
Auxiliary electrode: ORP Electrode.
Power supply: AC220V±10% 50HZ
Outline dimensions: 48×96×100mm (height×width×depth)
Slot dimension for installation : 45×91mm (height × width)
Installation: Jam-in
pH/ORP-542 pH /ORP Meter

Performance Features:
pH/ORP-542 meter is an industrial
on-line analysis and monitoring
instrument. It’s with various software
functions, and has such features as easy
installation and operation, strong
anti-interference capability and little
amount of maintenance work.
High-accuracy temperature
compensation and pH operation
compensation is also adopted.
Functions
— pH or ORP can be selected through menu.
— Back ground LCD digital display.
— Direct reading and accurate control with Micro chip for data processing
— Automatic or manual three-point calibration, which improves the measurement accuracy of the
instrument.
— 4~20mA current output for long-distance transmitting.
— It can optionally display pH mV value.
— Strong anti-interference capability and automatically reset in case of power off.

Main Technical Specifications

pH measurement range :0~14 pH


ORP measurement range :0~±1000mV
Resolution :0.01 pH, ±1mV
Accuracy :±0.05 pH, ±1mV
Electrode pressure resistance: 0~0.6Mpa
Power supply: AC 220V±10% 50Hz
Distance limit of measurement: ≤20m (standard configuration for electrode cable 10m). Please use
pH /ORP transmitter for overlong range.
Temperature of measured solution: 0~80℃
Environment conditions: humidity: ≤85%/RH; no strong electro-magnetic field interference except
earth magnetic field; no obvious acid or alkali mirage around .
Manual temperature compensation: 0~99℃
Output signal : non-isolated 4~20 mA
Load impedance:300Ω
Outline dimensions: 48×96×100mm (height×width×depth)
Instrument panel hole: 45×91mm
Installation: Jam-in
pH/ORP-540 pH/ORP Meter
Performance Features:
pH/ORP-540 meter is an industrial on-line analysis and monitoring instrument. It’s with various
software functions, and has such
features as easy installation and
operation, strong anti-interference
capability and little amount of
maintenance work. High-accuracy
temperature compensation and pH
operation compensation is also
adopted.
Functions
— pH or ORP can be selected
through menu.
— Back ground LCD digital display.
— Direct reading and accurate control with Micro chip for data processing
— Automatic or manual three-point calibration, which improves the measurement accuracy of the
instrument.
— It can optionally display pH mV value.
— Strong anti-interference capability and automatically reset in case of power off.
Main Technical Specifications
pH measurement range : 0~14 pH
ORP measurement range: 0~±1000mV
Resolution : 0.01 pH, ±1mV
Accuracy: ±0.05 pH, ±1mV
Electrode pressure resistance: 0~0.6Mpa
Power supply: AC 220V±10% 50Hz
Distance limit of measurement: ≤20m (standard configuration for electrode cable 10m). Please use
pH /ORP transmitter for overlong range.
Temperature of measured solution: 0~80℃
Environment conditions: humidity: ≤85%/RH; no strong electro-magnetic field interference except
earth magnetic field; no obvious acid or alkali mirage around .
Manual temperature compensation: 0~99℃
Outline dimensions: 48×96×100mm (height×width×depth)
Display: 3.5 bit LCD
Auxiliary: Plastic shell double combination electrode
Output signal: pH /ORP -540, It can optionally display pH mV value
Instrument panel hole: 45×91mm
Installation: Jam-in
TRANSMITTER
pHT-5431 pH Transmitter

Performance Features:
Welcome to use pH-5431 isolated pH transmitter. It apply to pH signal collect of long distance and pH
signal output , the direct output standard current signal is 4~20mA.
It’s with various software functions, and has such features as easy installation and operation, strong
anti-interference capability and little amount of
maintenance work. High-accuracy temperature
compensation and pH operation compensation is
also adopted.
Functions and Main Technical
Specifications
Functions
— Back ground LCD digital display.
— Direct reading and accurate control with
Micro chip for data processing
— Automatic or manual three-point calibration, which improves the measurement accuracy of the
instrument.
— 4~20 mA current output is isolate, transferable, reversal, and can switch output mode of the
meter and transmitter.
— It has functions of menu input and operation error compensation.
— It can optionally display pH, mV value.
— It has strong anti-interference and automatically breaks away the power.
— It has the proof –water panel and operation keyboard.
Main Technical Specifications
pH measurement range :0~14 pH
Resolution: 0.01 pH
Accuracy : ±0.1 pH
Electrode pressure resistance: 0~0.6Mpa
Display: 3.5 bit LCD digit display
Distance limit of electrode cable: ≤20m (standard configuration for electrode cable: 10m). The
maximum load impedance: 500Ω Max @ DC24V
Temperature of measured solution: 0~99℃
Manual temperature compensation: 0~99℃
Environment conditions: temperature:0~50℃, humidity: ≤85%/RH; no strong electro-magnetic field
interference except earth magnetic field
Power supply : DC 24V±10%
mA output: isolate, transferable, reversal 4~20 mA current, the switch output mode of meter and
transmitter.
Outline dimensions: 130×70×50mm (height×width×depth)
Installation: Pipe or plane installation
CT-121Conductivity Transmitter
Performance Features:
Conductivity Transmitter CT-121 is designed with one-piece
and hermetic, as a PLC controller and primary instrument of
monitor and controller, the transmitter has characters of
water-proof, damp-proof and installed directly at scene,
anti-interference, easy installation and good weatherability
etc.
Specifications
— Sealed, water-proof, one-piece design, fix settings
included.
— Double line transmission, non-polarity
connection(automatic identification of the polarity)
— Surface SMT technology
— 4~20mA standard current signal;
— DC24V power supply
— 316L/Ti metal electrode
— Automatic temperature compensation

Technical parameters:
— Measure range: 0~20;0~200;0~2000μS/cm
— Accuracy: ±1.5%(FS) of the readings
— Shell: epitheca: ASA; Lower casing: nylon
— Electrode: electrode:316L
— Weight: about 200g
— Operation environment: 0~50℃
— Storage temperature: -15~60℃
— Relative humidity: 0~100%RH
— Current output: 4~20mA, in series
— Power: DC 24V±5%
— Maximum circle resistance: 24V@600Ω
— Accuracy/precision: ±0.3mA@25℃
— Installation: pipe installation
DBY-5100/5200 Conductivity Transmitter
Performance features
5100 is an integration mode conductivity transmitter.
5200 is a fission mode conductivity transmitter. They can
meet long distance measurement of water solution
conductivity in the industrial processes. The all sealed
shell design meet the IP65 defending technology grade ,
can adapt to the wet environment .The any transferable
4~20mA isolated current sgnal can realize the operation
mode of meter/transmitter by change the connection
mode.
Technical Specification
Conductivity measurement range:
Electrode constant 0.1cm-1 : 0~20 μS/cm, 0~200 μS/cm
(optional)
Electrode constant 1.0cm-1 : 0~20 μS/cm, 0~200 μ S/cm 0~2000 μS/cm (optional)
Electrode constant 10.0cm-1 : 0~200 μS/cm, 0~2000 μS/cm 0~20 mS/cm (optional)
Temperature measurement range :0~50℃
Accuracy:1.5%(FS)
Stability: ±2×10-3 (FS)/24h
Signal output : isolate , transferable 4~20mA current ,
the optional output mode of meter/transmitter
Power supply: DC 24V±10%
Temperature of measured solution: 5~50℃
Defending types :IP65 defending grade
The max circulative resistance : DC 24V@600Ω
Display mode : Conductivity : 3.5bit LCD digital
display , Temperature : 3bit digital display
Outline dimensions: 130×70×50mm (height×width×depth)
Installation mode: pipeline installation(5100), plane installation(5200).
DBY-5600 Explosion-proof Conductivity Transmitter
Performance features
The conductivity transmitter can meet Inflammable,
explosive gas ‘s industrial environment design. With the
transferable 4~20mA isolated current signals, can change
the connection mode which realize meter /transmitter’s
operation mode .
It uses the micro processor to control the intelligent
operation. It’s with various software functions, and has
such features as choosing electrode mode, switch
measurement range, constant calibration, and
temperature compensation.
Technical Specification:
Conductivity measurement range:
Electrode constant 0.1cm-1 : 0~20 μS/cm, 0~200 μS/cm (optional)
Electrode constant 1.0cm-1 : 0~20 μS/cm, 0~200 μ S/cm ,0~2000 μS/cm (optional)
Electrode constant 10cm-1 : 0~200 μS/cm, 0~2000 μS/cm, 0~20 mS/cm (optional)
Accuracy :1.5%(FS)
Stability: ±2×10-3 (FS)/24h
Power supply: DC 24V±10%
Temperature of measured solution: 5~50℃
Environment conditions: Temperature :5~50℃
humidity:≤85%RH;
The max circulative resistance : DC 24V@600Ω
Display mode : Conductivity 3.5bit LED digital display ,
The signal output: Isolated, transferable current 4~20mA , optional output mode of meter and
transmitter.
Defending type : Exd ⅡcCT6 defending grade
Installation: jam-in or fission
HL-360 Loop Meter
Performance and applications:
The instrument can display and control the industrial process conductivity transmitter, resistivity
transmitter and pH transmitter; it has
functions of conductivity, resistivity, pH
value displaying, over limit alarm,
control output etc. This meter also can
be used as the second instrument for
displaying conductivity, resistivity, and
pH value. Double line mode 4-20mA
standard current transfer, and advanced
anti-interference capability were
adopted.
This instrument meets the needs of long-distance measure, display and control operation between the
control room and the industrial place.

Main technical specifications:


Micro CMOS chip for data processing read directly and control accurately, automatic replacement
when power off.
Automatic and freely calibration of two point ratio and selectable relay control output of high/low
limit alarm.
Display mode: 3½ bit backlight LCD digital display
Display(selectable): μS/cm、mS/cm、MΩ▪cm、pH、mA value.
Input signal: 4~20mA
Conductivity measure range: 0~20μS/cm, 0~200μS/cm, 0~2000μS/cm;
0~20 mS/cm, 0~200mS/cm, 0~2000mS/cm
Resistivity measure range: 0~20.00 MΩ▪cm
pH measure range: 0~14pH
mA value measure range: 0~19.99mA
Accuracy: ±1.0 %( FS)
Stability: ±2×10 -3(FS)/24h
Contact capacity: 5A/250V AC (for resistive load)
Environment Conditions: temperature: 0~50℃, relative humidity:≤85%/RH
Power supply: AC220V±10% 50HZ
Dimensions: 48×96×100mm (height ×width ×depth)
Slot dimensions for installation: 45×91mm (high × width) Installation: Jam-in
ELECTRODE
DCS1121—1.0cm-1 Conductivity Electrode

Usage: Conductivity measurement of weak electrolyte, include industrial water,


cooling water, pure water etc.

Features: ABS fast installation, screw thread, Pipeline installation and side
installation on the tank

Specification: Electrode constant: 1.0 cm-1

Performance:
Electrode type: two sensor system.
Material: engineering plastic framework, stainless steel underlay with platinum
black
Temperature compensation components: NTC 10KΩ
Connection: 1/2″NPT (ABS fast installation)
Pressure: 0.5 MPa
Medium temperature: 0-50 ℃
Coil out:outgoing cable directly
Cable Length: 5 meters long Ex-factory or made by requirement
DCG1121-1.0~0.01cm-1 Electrode

Usage: Conductivity measurement of industrial water, cooling water,


pure water, high-pure water, ultra water etc.

Performance:
Electrode type: Two sensor system
Material: 316 L Stain Steel
Temperature compensation components: NTC 10KΩor Pt100/1000
Connection: 1/2″NPT (ABS fast installation)
Pressure: 0.5 MPa
Medium temperature: 0-50 ℃
Cable Length: 5 meters long Ex-factory or made by requirement

Features:
316 L Stain Steel, corrosion proof, long-time using

Specification:
Electrode constant: 1.0 、0.1、0.05 、0.01cm-1
DCT1121-0.1~0.01cm-1 Electrode

Usage: Conductivity measurement of pure water, high-pure water, ultra


water etc.

Features: titanium metal, corrosion resistance, anti electricmagnetic


field interference, good hydration

Specification: Electrode constant: 0.1、0.01cm-1

Performance:
Electrode type: two sensor system
Material: titanium metal
Temperature compensation components: NTC 10K or Pt100/1000
Connection: 1/2″NPT (ABS fast installation)
Pressure: 0.5 MPa
Medium temperature: 0-50 ℃
Coil out:outgoing cable directly
Cable Length: 5 meters long Ex-factory or made by requirement
DCT3121-1.0~0.01cm-1 Electrode

Usage: Conductivity measurement of industrial water, cooling water, pure

water, high-pure water, ultra water etc.

Electrode type: 316 L Stain Steel, corrosion resistance, long useful life

Specification: Electrode constant: 1.0,0.1,0.05 0.01cm-1

Performance:

Electrode type: two sensor system

Material: 316 L Stain Steel

Temperature compensation components: NTC 10K or Pt100/1000

Connection: 1/2″NPT (Stain steel fast-installation joint)

Pressure: 0.5 MPa

Medium temperature: 0-50 ℃

Coil out:outgoing cable directly

Cable Length: 5 meters long Ex-factory or made by requirement


DCG2132-0.1~0.01cm-1 Electrode
Usage: Conductivity measurement of steam condensation water, bottom
water of boiler

Feature: 316 L Stain Steel, corrosion resistance, High temperature, and


high-pressure

Specification: Electrode constant: 0.1,0.01cm-1

Performance:
Electrode type: two sensor system
Material: 316 L Stain Steel
Temperature compensation components: NTC 10K or Pt100/1000
Connection: 1/2″NPT, Stain steel cube.
Pressure: 0.5 MPa
Medium temperature: 60~120 ℃
Coil out:outgoing cable directly
Cable Length: 5 meters long Ex-factory or made by requirement
DCS0120-1.0cm-1 Electrode
Usage: Conductivity measurement of weak electrolyte, include industrial
water, cooling water, tap water, pure water etc.

Features: solid shell, legerity, easy to carry.

Specification: Electrode constant: 1.0 cm-1

Performance:
Electrode mode: Two sensor system
Material: Plastic shell, stainless steel underlay with platinum black
Temperature compensation components: NTC 10KΩ
Medium temperature: 0-50 ℃
Coil out:outgoing cable directly
Cable Length: 5 meters long Ex-factory or made by requirement
DCG-7121 Microminiature Integration Conductivity
Sensor for Ultra Pure water

Usage
Be widely used in the Power House, Chemistry, Medicine Making,
Environment Protection, Paper Making, Food, Water Supply…

Technical Features
— Design in the integration
— Made by 316L S.S
— Effective measurement space, no backwater or dead angle,
improve the measure accuracy.
— Smaller size and convenient connection.

Main Technical Specification


— Electrode constant : 0.01 cm -1 , 0.05 cm -1
— Electrode mode: temperature compensation electrode.
— Material: 316 L SS
— Temperature compensation component:NTC or Pt
— Pressure : 0.6 MPa
— tangential : 0-50℃
— Coil out:outgoing cable directly and then screw on by cap.
— Cable length:0.5m Ex-factory.
DCS-4321 Conductivity Sensor

Usage

Used in the seawater desalination, bitter, acid solution, aqueous

alkali …

Main Technical specification:

Material: 316 L Stain Steel, Teflon, corrosion resistance, long useful life

Specification: Electrode Constant: 10.0 cm-1

Electrode mode: temperature compensation electrode

Temperature compensation component:NTC 10 KΩ or Pt100/1000

Connection: 3/4″ NPT.

Pressure: 0.5 MPa

Medium temperature: 0-50 ℃

Coil out:outgoing cable directly and then screw on by cap.

Cable Length: 5 meters long Ex-factory or made by requirement.


WOL-0321-5 Sensor of Turbo Flow

Usage
Petroleum, chemistry, metallurgy, water supply, paper making, industry
cooling system, water treatment system…

Technical parameter:
Material: ABS plastic
Measurement: tangential measurement
Medium temperature: 0-60 ℃
Storage temperature:-20 ~80 ℃
Pressure: 0.6 MPa
Power supply: 12 V DC
Pulse output: ≥ 8V
Transmit distance: ≥ 1000 M
Pipe diameter: DN-25 ~ DN 200
Pipe material: plastic, metal, glass fiber reinforced plastic, cement.
Environment: There is no strong alternative magnetic field around the
electrode.
Medium requirement: Install the Y filter when there is some granule exists in the pipeline.
PC202 Plastic pH Combination Electrode

Range:0-14pH Temperature:0-100℃
Pressure:0.6MPa Process connection:Top & bottom 3/4 inch NPT, threads
Material:PPS Cable connection:connected by low noise cable directly
Characteristics:
Adopt the most advanced solid electrolyte and Tetrafluoroethlene liquid junction which resist to be
blocked and maintenance conveniently.
Long distance diffusion path of reference solution extended the useful life under the harsh conditions.
Wider temperature range can be used in explosion-protection area.
New design of glass bulb, increase surface area of it and prevent inner buffer solution from interfere of
air bulb to gain reliable measurement.
Adopt PPS body, top/bottom 3/4 inch threads that easy to be installed and no housing needed, saving
the cost of installation.
Use high quality low noise cable, the distance of output signals is longer than 20 meters without
disturbance.
Application area:
Medicine, chlorine-alkali chemical-engineering, paint & dye, paper making, intermediate, fertilizer,
starch, environment-protection… ; temperature fluctuation less than 10℃.
PCORP Plastic ORP Combination Electrode

Measure range:±2000mV Temperature range:0-100℃


Pressure:0.6MP Installation dimension:Top & bottom 3/4 inch NPT, threads
Materials:PPS Connection:low noise cable directly
Characteristics:
Adopt the most advanced solid electrolyte and Tetrafluoroethlene liquid junction which resist to be
blocked and maintenance conveniently.
Long distance diffusion path of reference solution extended the useful life under the harsh conditions.
Wider temperature range can be used in explosion-protection area.
Adopt PPS body, top/bottom 3/4 inch threads that easy to be installed and no housing needed, saving
the cost of installation.
Use high quality low noise cable, the distance of output signals is longer than 20 meters without
disturbance.

Application area:
Be used for the ORP testing of Medicine, chlorine-alkali chemical-engineering, paint & dye, paper
making, intermediate, fertilizer, starch, environment-protection…
G102 pH Combination Electrode

Measure range:2-12pH Temperature range:0-60℃


Pressure:0.3MP Dimension:diameter12×120mm
Material: Glass Connection:AS7、PG13.5 threads international standard

Characteristics:
Apply big area low impedance sensitive membrane bulb, suitable for pure water application.
Apply gel type electrolyte, solid bridge electrolyte. Electrophoresis cell consists of two different kinds of
gel electrolytes, make sure longer working life of the electrode and reliable readings.
International standard connection, can replace imported electrodes directly.

Application area:
Water treatment, pure water industry.
——CREATE

Your reliable business partner!

You might also like