Compressor Trouble Shouting
Compressor Trouble Shouting
Check Remedy
Main disconnect
switch Close switch
open
Control transformer
Replace fuse
fuse blown
Reset. If trouble is
Motor starter persists, check whether
overload tripped motor starter contacts
are functioning or not
Emergency
Replace emergency
push button
push button/replace
locked/malfunction
Incoming R YB Change if
phase connection accordingly
17.0
Troubleshooting
Check Remedy
Stand by time
10 minutes Reset
(6 times start & stop accordingly
allowed.)in 1 Hr
17.1
Troubleshooting
Problem : High discharge temperature
Check Remedy
Proper ventilation in Make arrangement
for proper
exhaust and inlet Ventilation
Provide required
Insufficient space
space around the
around compressor compressor
emperature
T sensor
in ambient Calibrate it
17.2
Troubleshooting
Check Remedy
Loading/Unloading
Do proper compressor
pattern, if unloading is
selection
more than loading
Oil level
too high Drain the oil to
(off condition) correct level
17.3
Troubleshooting
Check Remedy
Replace pressure
Defective pressure
relief valve
relief valve
Replace separator
Defective separator
element
element
Set according to
Working pressure intended working
set in controller pressure
Replace the
High pressure separator element/
in the sump Clean the cooler
17.4
Troubleshooting
Check Remedy
Solenoid valve
malfunction Check and replace
17.5
Troubleshooting
Check Remedy
Defect in pressure
Check and replace
transmitter
Defective solenoid
Check and replace
valve
17.6