Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

61213.16.

23

18,579
8 7 6 5 4 3 2 1 825,579

REVISIONS
ZONE REV ECN DESCRIPTION DATE DRAWN APP'D

A 81554 ORIGINAL RELEASE 2013MAR04 R. REDMON J. BROWN

RED RED
2
DIS CON 3
WHT
GRN PCB3
WHT
GRN PCB2
5
BLK
PE L1 L2 L3 3FU
D BLK
D
1
1 1 12V

P10
J2
24V 2LT 7
2 2 gnd
L3 1FU 1Ma

24V
2Ma

J1
2 8
GND
9
5 PCB1 1Sa
T1 10
3 1 1OL-1
J3 11
L1 1FU

P4
110/120V 2FU 2 2 MMS-1

J4
BRN BRN 12
GND 1 2 3 4 1 3
13 CPS
RFI 1LT

GRN/YEL

P3
BRN
P

BLU

BLK
0V 14
BLU BLU
1TB-1 15

P7
1TB-10
16
ES-2
17
18

P8
200-460V
GND GND 3MTR RSP
19
UNITS MCB1 1TB-10 7SV 20 RST
0.5A 1 5
1TB-6 2 6 21
RST

P9
N/O L3 3 7 22
1TB-11 5SV 1TB-1
C L2 1Mc REMOVE WIRE 4 8 23
IF LVM INSTALLED RLL
C N/C L1 RC2 1PS
24 C
ES-1 1ATS P 25
1TB-11 4SV RLE
LVM 26
1
(OPTIONAL)
1TB-2 1TB-3 1TB-4 LVM 1TB-5 27 RLU
(OPT) 28
1M 2M 1S
1TB-12 1M 2 29
1Sb A1W
30
1Sc
1TB-12 2M 31
1Mb A2W
32
RC1
2Mb RED
L1 L2 L3 MMS 1TB-12 1S 3 1
BLK
2 1AVPT
WHT
1TB-13 3SV 5 3
RED
1OL 4
BLK

P1
5 3APT
WHT
6
RED
1TB-13 SAR 7 7
BLK
8 4APT
T1 T2 T3 T1 T2 T3 T6 T4 T5 WHT
1TB-14 CWO 8 9
RED

P5
B 13 B
BLK
1TB-14 PORO 9 14 6APT
WHT
15
2MTR 1MTR (OPTIONAL) 16
1TB-14 10 RED
22
BLK
23 RPS
WHT
L1 L2 L3 24
575V UNITS (OPTIONAL)

ONLY 305 1 N/O


1
WHT
6FU CTO 306 2 C BLK 2CTT
0.1A 2
307 3 N/C WHT
N/O L3 3

P2
2ATT

P6
308 4 N/O BLK
C L2 4
CWO 309 5 C
5
WHT
N/C L1 BLK 4ATT
310 6 N/C
6FU 6
LVM 0.1A
(OPTIONAL)
FOR NOTES AND LEGEND
SEE OPERATORS MANUAL. 24486219 REV A

A A
DO NOT SCALE DRAWING
402,81 615,81 825,81

STANDARD TOLERANCES WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED
BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. DRAWING CONFORMS TO
ALL DIMENSIONS ARE IN ASME Y14.5M - 1994
THIRD ANGLE PROJECTION

NOTES: MILLIMETERS
[INCHES (IF SHOWN)]
PROPRIETARY NOTICE
CAD GENERATED DRAWING,
DRAWN DATE

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET R. REDMOND 2013MAR04


INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED CHECKED DATE TITLE

1. DECAL MUST CONFORM TO THE LATEST UNSPECIFIED TOLERANCES: GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE UNLESS OTHERWISE SPECIFIED:
B. WARREN /J.M. 2013MAY22 DECAL, WIRING SCHEMATIC (Xe),
REVISION OF I-R SPECIFICATION 92-8.95 AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY APPROVED DATE

SD, LVM, PORO, REMOTE ALARM


- REMOVE ALL BURRS AND SHARP CORNERS
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY - WELD SYMBOLS TO BE IN ACCORDANCE J. BROWN 2013MAY22
WHOLE : 1 THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION
ONE PLACE (.X) : 0.5 WITH ANSI/AWS A2.4 DRAWING TYPE
DECAL, WIRING SCHEMATIC (Xe), SD, LVM, PORO, REMOTE ALARM

THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS SIZE ESTIMATED WEIGHT DWG NO. REV
TWO PLACE (.XX) : 0.25 Detail Drawing
A1 24486219 A
24486219

EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET (KG UNLESS OTHERWISE SPECIFIED)
ANGLES (.X) : 1 INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO COPYRIGHT @ 2013 NOMENCLATURE
0.0 kilogram
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL Ingersoll Rand
18,18
Ingersoll-Rand Industrial Technologies 402,18
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. ALL RIGHTS RESERVED
SCALE: UNIT:
SSR 250-500HP 2STG SHEET
1 OF 4For Internal Use:24486219|PART|A.4|Randy Redmond|31-May-13 10:01:56 AM|In Work

8 7 6 5 4 3 2 1
31-May-2013 10:06:23 (model A.4/A.2)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED A.2
61213.16.23

18,579
8 7 6 5 4 3 2 1 826,579

LEGEND LEGEND
ABBREV DESCRIPTION ABBREV DESCRIPTION
PE EARTH LEAD, MAIN TERMINAL 2ATT SENSOR, TEMPERATURE - AIREND DISCHARGE
GND EARTH/GROUND 2CTT SENSOR, TEMPERATURE - INJECTED COOLANT
DIS MAIN DISCONNECT (CUSTOMER SUPPLIED) 4ATT SENSOR, TEMPERATURE - PACKAGE DISCHARGE
D L1-L3 MAIN TERMINALS IPS SWITCH, INTERSTAGE PRESSURE D
1FU-3FU CONTROL FUSE (3FU MUST BE A FAST (TWO STAGE UNIT ONLY)
ACTING TYPE BBS FUSE) CPS SWITCH, COOLANT DELTA PRESSURE
T1 TRANSFORMER, 110-1-50 OR 120-1-60, 24V 1TB TERMINALS
TRANSFORMER/FUSE SIZE: P7 SERVICE TOOL PORT
T1(VA) 1FU(A) 2FU(A) 3FU(A) P8 ETHERNET
280 1.8 2.0 5.0 P9 EXTERNAL COMMUNICATIONS
380 2.5 3.2 5.0 RLL REMOTE LEAD/LAG SWITCH
580 3.5 5.0 5.0 RLE REMOTE LOAD ENABLE SWITCH
625 3.5 5.0 8.0 RLU REMOTE LOAD/UNLOAD SWITCH
A1W AUXILIARY WARNING INPUT #1
1M MAIN CONTACTOR
A2W AUXILIARY WARNING INPUT #2
1Ma- c MAIN CONTACTOR AUXILIARY CONTACTS
2M DELTA CONTACTOR
2Ma- d DELTA CONTACTOR AUXILIARY CONTACTS
1S STAR CONTACTOR LEGEND
1S a- c STAR CONTACTOR AUXILIARY CONTACTS ABBREV DESCRIPTION
1MTR MAIN DRIVE MOTOR
BLK BLACK
C 2MTR FAN MOTOR C
BLU BLUE
3MTR STEPPER MOTOR
GRN GREEN
1OL MAIN MOTOR OVERLOAD RELAY
RED RED
MMS FAN MANUAL MOTOR STARTER
WHT WHITE
RFI RFI FILTER
YEL YELLOW
1LT LAMP, POWER ON - BACKPANEL
BRN BROWN
2LT LAMP, POWER ON - INSTRUMENT PANEL
GRN/YEL GREEN/YELLOW
PCB1 PRINTED CIRCUIT BOARD, POWER SUPPLY
PCB2 PRINTED CIRCUIT BOARD, STEPPER LIMIT
PCB3 PRINTED CIRCUIT BOARD, STEPPER LIMIT ADAPTER
ES EMERGENCY STOP
3SV SOLENOID VALVE, BLOWDOWN OPTIONS
4SV SOLENOID VALVE, WATER SHUT OFF
(WATER COOLED UNIT ONLY) LVM LINE VOLTAGE MONITOR
5SV SOLENOID VALVE, COOLANT STOP PORO HORN, POWER OUTAGE RESTART
(NOT REQUIRED ON UNITS WITH OIL PUMP) MCB1 CIRCUIT BREAKER
7SV SOLENOID VALVE, PRESSURE RELIEF
(REMOTE COOLED UNIT ONLY)
B 1ATS SWITCH, HIGH AIR TEMPERATURE B
RC1-2 ARC SUPPRESSORS
NOTES:
CON CONTROLLER
CTO COMMON TRIP OUTPUT 1. MAIN DISCONNECT AND BRANCH CIRCUIT PROTECTION TO BE PROVIDED
CWO COMMON WARNING OUTPUT BY CUSTOMER.
RPS REMOTE PRESSURE SENSOR 2. DASHED LINES REPRESENT WIRING BY CUSTOMER.
RSP REMOTE STOP 3. SIZING OF ELECTRICAL COMPONENTS, NOT SUPPLIED BY INGERSOLL-RAND,
RST REMOTE START IS THE RESPONSIBILITY OF THE CUSTOMER AND SHOULD BE DONE IN
SAR STOPPED IN AUTO RESTART ACCORDANCE WITH THE INFORMATION ON THE COMPRESSOR DATA PLATE,
USE WITH CUSTOMER SUPPLIED RELAY HAVING COIL RATING OF NATIONAL AND LOCAL ELECTRICAL CODES.
110VAC-50HZ, 120VAC-60HZ, 250MA MAXIMUM 4. IPS IS REPLACED WITH A JUMPER WIRE FROM 1TB-3 TO ITB-4 ON UNITS
1AVPT TRANSDUCER, PRESSURE - INLET VACUUM NOT REQUIRING AN INTERSTAGE PRESSURE SWITCH.
3APT TRANSDUCER, PRESSURE - SEPARATOR TANK WET SIDE
4APT TRANSDUCER, PRESSURE - PACKAGE DISCHARGE
6APT TRANSDUCER, PRESSURE - SEPARATOR TANK DRY SIDE

A A

636,54 825,54

PROPRIETARY NOTICE TITLE

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET


INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DECAL, WIRING SCHEMATIC (Xe),
IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY
SD, LVM, PORO, REMOTE ALARM
DECAL, WIRING SCHEMATIC (Xe), SD, LVM, PORO, REMOTE ALARM

RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE


DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT SIZE DWG NO. REV

24486219 A
24486219

A1
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE: SHEET
18,18 636,18
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 2 OF 4

8 7 6 5 4 3 2 1
31-May-2013 10:06:23 (model A.4/A.2)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED A.2
61213.16.23

18,579
8 7 6 5 4 3 2 1 826,579

SPANISH
IDENTIFICACION IDENTIFICACION
ABBREV DESCRIPCION ABBREV DESCRIPCION
PE CONEXION DE TIERRA, TERMINAL PRINCIPAL 2ATT SENSOR DE TEMPERATURA - DESCARGA DE UNIDAD DE AIRE
D GND TIERRA 2CTT SENSOR DE TEMPERATURA - LUBRICANTE DE INYECCION D
DIS DESCONEXION PRINCIPAL (SUMINISTRADA POR EL CLIENTE) 4ATT SENSOR DE TEMPERATURA - DESCARGA DEL PAQUETE
L1-L3 BORNES DE ALIMENTACION DE FUERZA IPS INTERRUPTOR DE PRESION ENTRE ETAPAS
1FU-3FU FUSIBLES DE CONTROL - 3FU DEBERA SER UN FUSIBLE (UNICAMENTE UNIDADES DE DOS ETAPAS)
BBS DE ACCION RAPIDA. CPS INTERRUPTOR, LUBRICANTE VARIACION DE
T1 TRANSFORMADOR, 110-1-50 OR 120-1-60, 24V PRESIION
CAPACIDADES DE TRANSFORMADOR/FUSIBLES: 1TB TERMINALES
T1(VA) 1FU(A) 2FU(A) 3FU(A) P7 SERVICIO DE HERRAMIENTAS PUERTO
280 1.8 2.0 5.0 P8 ETHERNET
380 2.5 3.2 5.0 P9 COMUNICACIONES EXTERNAS
580 3.5 5.0 5.0 RLL INTERRUPTOR DE AVANCE/RETARDO REMOTOS
625 3.5 5.0 8.0 RLE SWITCH REMOTO DE PERMISIBILIDAD DE CARGA
1M CONTACTOR DE OPERACION/ARRANQUE RLU SWITCH REMOTO DE PERMISIBILIDAD DE DESCARGA
1Ma- c CONTACTORS AUXILIARES DEL CONTACTOR DE OPERACION/ARRANQUE A1W ADVERTENCIA AUXILIAR ENTRADA #1
2M CONTACTOR DE OPERACION A2W ADVERTENCIA AUXILIAR ENTRADA #2
2Ma- d CONTACTORS AUXILIARES DEL CONTACTOR DE OPERACION
1S CONTACTOR DE ARRANQUE
1S a- c CONTACTORS AUXILIARES DEL CONTACTOR DE ARRANQUE
C 1MTR MOTOR DEL COMPRESOR IDENTIFICACION C
2MTR MOTOR DEL VENTILADOR
3MTR MOTOR DEL PASO
ABBREV DESCRIPCION
1OL RELE TERMICO DEL MOTOR BLK NEGRO
MMS ARRANQUE MANUAL DEL MOTOR DEL VENTILADOR BLU AZUL
RFI FILTRO RFI GRN VERDE
1LT LAMPARA, CORRIENTE CONECTADA - PANEL POSTERIOR RED ROJO
2LT LAMPARA, CORRIENTE CONECTADA - PANEL DE INSTRUMENTOS WHT BLANCO
PCB1 TARJETA DE CIRCUITOS IMPRESOS, ALIMENTACION DE CORRIENTE YEL AMARILLO
PCB2 TARJETA DE CIRCUITOS IMPRESOS, LIMITADOR DE PASOS BRN MARRON
PCB3 TARJETA DE CIRCUITOS IMPRESOS, LIMITADOR DE PASOS ADAPTADOR GRN/YEL VERDE/AMARILLO
ES PARADA DE EMERGENCIA
3SV SOLENOIDES DE EVACUACION
4SV SOLENOIDE DE CORTE DE AGUA
(UNIDADES ENFRIADAS POR AGUA, UNICAMENTE) OPCIONS
5SV SOLENOIDE DE CORTE DE REFRIGERANTE
LVM MONITOR DE VOLTAE
(NO SE REQUIERE EN UNIDADES CON BOMBA DE LUBRICACION)
PORO SIRENA DE ARRANQUE POR
7SV SOLENOIDE DE ALIVIO DE PRESION INTERRUPCION/FALLO DE POTENCIA
B B
(UNIDADES CON ENFRIADORES REMOTOS, UNICAMENTE)
MCB1 INTERRUPTORES DEL CIRCUITO
1ATS INTERRUPTOR POR ALTA TEMPERATURA DE AIRE
RC1-2 SUPRESORES DEL ARCO
CON CONTROLADOR
CTO SALIDA DE ZANCADILLA COMÚN NOTAS:
CWO SALIDA DE ADVERTENCIA COMÚN
RPS TRANSDUCTO DE PRESION - REMOTA 1. EL INTERRUPTOR PRINCIPAL Y LA PROTECCION DEL CIRCUITO SERAN
RSP PARADA REMOTA SUMINISTRADOS POR EL CLIENTE.
RST ARRANQUE REMOTO 2. LINEAS DISCONTINUAS REPRESENTAN CABLEADO SUMINISTRADO POR EL CLIENTE.
SAR SALIDA DE AVISO REMOTA, SUMINISTRO DEL CLIENTE 3. LA SELECION DE COMPONENTES ELECTRICIOS NO SUMINISTRADOS POR INGERSOLL-
CALIBRANDO EL ENBOBINADO DE RAND ES RESPONSABILIDAD DEL CLIENTE Y DEBERA SER HECHA DE ACUERDO CON
110 VAC 50HZ, 120 VAC 60HZ, CON UN MAXIMO DE 250 MA DE PLACA DEL COMPRESOR, N.E.C. Y LOS CODIGOS ELECTRICOS LOCALES.
1AVPT TRANSDUCTOR DE PRESION - VACIO DE ADMISION 4. EL IPS ES REEMPLAZADO POR UN ALAMBRE CONECTOR DESDE 1TB-3 A 1TB-4 LAS
3APT TRANSDUCTOR DE PRESION - TANQUE SEPARADOR LADO HUMEDO UNIDADE QUE NO REQUIEREN UN INTERRUPTOR DE PRESION ENTRE ETAPAS.
4APT TRANSDUCTOR DE PRESION - DESCARGA DE LA UNIDAD
6APT TRANSDUCTOR DE PRESION - TANQUE SEPARADOR LADO SECO

A A

636,54 825,54

PROPRIETARY NOTICE TITLE

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET


INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DECAL, WIRING SCHEMATIC (Xe),
IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY
SD, LVM, PORO, REMOTE ALARM
DECAL, WIRING SCHEMATIC (Xe), SD, LVM, PORO, REMOTE ALARM

RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE


DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT SIZE DWG NO. REV

24486219 A
24486219

A1
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE: SHEET
18,18 636,18
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 3 OF 4

8 7 6 5 4 3 2 1
31-May-2013 10:06:23 (model A.4/A.2)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED A.2
61213.16.23

18,579
8 7 6 5 4 3 2 1 826,579

PORTUGUESE
LEGENDA LEGENDA
ABBREV DESCRIPTION ABBREV DESCRIPTION
D PE CABO DE TERRA, TERMINAL DE REDE 2ATT SENSOR, TEMPERATURA - DESCARGA UNIDADE D
GND TERRA 2CTT SENSOR, TEMPERATURA - INJECAO LUBRIFICANTE
DIS INTERRUPTOR PRINCIPAL (FORNECIDO PELO CLIENTE) 4ATT SENSOR, TEMPERATURA - DESCARGA COMPRESSOR
L1-L3 TERMINAIS PRINCIPAIS IPS PRESSOSTATO INTERESTAGIAL
1FU-3FU FUSIVEL DE CONTROLE - O FUSIVEL 3FU DEVERA SER (SOMENTE NAS UNIDADES DE DOIS ESTAGIOS)
TIPO BBS DE ACAO RAPIDA CPS INTERRUPTOR, DELTA-P LUBRIFICANTE
T1 TRANSFORMADOR, 110-1-50 OR 120-1-60, 24V 1TB REGUA DE BORNES
TAMANHO TRANSFORMADOR/FUSIVEL: P7 SERVIÇO DE FERRAMENTA PORT
T1(VA) 1FU(A) 2FU(A) 3FU(A) P8 ETHERNET
280 1.8 2.0 5.0 P9 COMUNICAÇÕES EXTERNAS
380 2.5 3.2 5.0 RLE BOTAO REMOTO DE ACIONAMENTO DO LIDER
580 3.5 5.0 5.0 RLL BOTAO REMOTA DE LIDER/ESCRAVO
625 3.5 5.0 8.0 RLU BOTAO REMOTO DE CARGA/ALIVIO
1M CONTATOR OPERAR/PARTIR A1W ADVERTENCIA DA ENTRADA AUXILIAR #1
1Ma- c CONTATOS AUXILIARES CONTATOR OPERAR/PARTIR A2W ADVERTENCIA DA ENTRADA AUXILIAR #2
2M CONTATOR OPERAR
2Ma- d CONTATOS AUXILIARES CONTATOR OPERAR
1S CONTATOR PARTIR
C C
1S a- c
1MTR
CONTATOS AUXILIARES CONTATOR PARTIR
MOTOR DO COMPRESSOR
LEGENDA
2MTR MOTOR DO VENTILADOR ABBREV DESCRIPTION
3MTR MOTOR DE PASSOS BLK PRETO
1OL TERMICO DE PROTECAO DO MOTOR BLU AZUL
MMS ARRANCADOR MANUAL DO MOTOR DE VENTILADOR GRN VERDE
RFI RELE DE RFI RED VERMELHO
1LT LUZ, CORRENTE LIGADA - PAINEL TRASEIRO WHT BRANCO
2LT LUZ, CORRENTE LIGADA - PAINEL DE INSTRUMENTOS YEL AMARELO
PCB1 PLACA DE CIRCUITO, ABASTECIMENTO DE CORRENTE BRN MARROM
PCB2 PLACA DE CIRCUITO, PASSO LIMITADORA GRN/YEL VERDE/AMARELO
PCB3 PLACA DE CIRCUITO, PASSO LIMITADORA ADAPTADOR
ES PARADA DE EMERGENCIA
3SV SOLENOIDE DE ALIVIO
4SV SOLENOIDE BLOQUEIO AGUA
(SOMENTE NAS UNIDADES REFRIGENRADAS A AGUA) OPCOS
5SV SOLENOIDE BLOQUEIO OLEO
(NAO NECESSARIO NAS UNIDADES COM BOMBA DE OLEO) LVM MONITOR LINHA DE VOLTAGEM
B PORO BUZINA, NOVA PARTIDA B
7SV SOLENOIDE ALIVIO PRESSAO
(SOMENTE NAS UNIDADES COM RESFRIADOR REMOTO) MCB1 DISJUNTORES
1ATS CONTATO ALTA TEMPERATURA DO AR
RC1-2 SUPRESSORES DE ARCO
CON CONTROLADOR
CTO SAÍDA TRIP COMUM NOTAS:
CWO SAÍDA AVISO COMUM
SAR PARTIDA-PARADA AUTOMATICA 1. CHAVE INTERRUPTORA PRINCIPAL E RAMAL DO CIRCUITO DE PROTECAO, A SEREM
RSP PARADA REMOTA FORNECIDOS PELO CLIENTE.
RST PARTIDA REMOTA 2. LINHAS TRACEJADAS REPRESENTAM FIACAO ELETRICA DO CLIENTE.
1AVPT TRANSDUTOR, PRESSAO - VACUO ADMISSAO 3. DIMENSIONAMENTO DOS COMPONENTES ELETRICOS, NAO E FORNECIDO PELA
3APT TRANSDUTOR, PRESSAO - PRESSAO TANQUE SEPARADOR UMIDO INGERSOLL-RAND, E DE RESPONSABILIDADE DO CLIENTE E DEVE SER
4APT TRANSDUTOR, PRESSAO - PRESSAO DESCARGA UNIDADE EXECUTADO DE ACORDO COM AS INFORMACOES DE PLACA DO COMPRESSOR E
6APT TRANSDUTOR, PRESSAO - PRESSAO TANQUE SEPARADOR SECO COM AS NORMAS ELETRICAS LOCAIS E NACIONAIS.
RPS TRANSDUTOR, PRESSAO - REMOTO 4. IPS E SUBSTITUIDO POR UM JUMPER ENTRE 1TB-3 E 1TB-4 NOS COMPRESSORES
SEM PRESSOSTATO INTERESTAGIAL.

A A

636,54 825,54

PROPRIETARY NOTICE TITLE

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET


INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DECAL, WIRING SCHEMATIC (Xe),
IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY
SD, LVM, PORO, REMOTE ALARM
DECAL, WIRING SCHEMATIC (Xe), SD, LVM, PORO, REMOTE ALARM

RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE


DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT SIZE DWG NO. REV

24486219 A
24486219

A1
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE: SHEET
18,18 636,18
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 4 OF 4

8 7 6 5 4 3 2 1
31-May-2013 10:06:23 (model A.4/A.2)