Brief description Due to short circuit in the relay, the wiring harness can be overheated,
insulation destroyed and short circuit to engine block can occur.
Before starting any work, check the engine serial number in Product Center
to determine if the engine is affected by this or any other campaign.
If the products have been exported from your market inform Volvo Penta
MU or VP importer in the receiving market.
Method 1. Replace the relay p/n 21928877 with relay p/n 23314469.
2. Install the wiring harness p/n 23841004 between the relay and the EMS.
3. Secure the harness with cable ties (see example pictures depending on
engine).
4. Perform test after repair.
Page Group Number Version AB Volvo Penta
2(3) 33-3 101 1 Service Bulletin
D5/D8 engine
P0033041
D11 engine
P0033042
Compensation Main op. 0000-00-09-00. Pre heat relay replace. 0.3h (M)
Additional op. 0000-00-09-01. Adapter harness, install. 0.3h (M)
Additional op. 0000-00-09-02. Perform test after repair. 0.3h (M)