Enclosed, Partially Enclosed Buildings: Gable Roofs θ ≤ 70

Notes:
1. Vertical scale denotes GCP to be used with qh.
2. Horizontal scale denotes effective wind area, in square meters.
3. Plus and minus signs signify pressures acting toward and away from the
surfaces, respectively.
4. Each component shall be designed for maximum positive and negative
pressures.
5. If a parapet equal to or higher than 0.9 m is provided around the perimeter of
the roof with θ ≤ 70, the negative values of GCp in Zone 3 shall be equal to
those for Zone 2 and positive values of GCP in Zones 2 and 4 shall be set
equal to those for wall Zones 4 and 5 respectively in Figure 6.2.11(a).
6. Values of GCP for roof overhangs include pressure contributions from both
upper and lower surfaces.
7. Notation:
a: 10 percent of least horizontal dimension or 0.4h, whichever is smaller, but
not less than either 4% of least horizontal dimension or 0.9 m.
h: Eave height shall be used for θ ≤ 100.
θ: Angle of plane of roof from horizontal, in degrees.

Figure 6.2.11(b) External pressure coefficients, GCp for components and cladding–
Method 2 (h ≤ 18.3 m)

BNBC 2020 Part VI Chapter 2


evsjv‡`k †M‡RU, AwZwi³, †deªæqvwi 11, 2021 3161

Enclosed, Partially Enclosed Buildings: Gable/Hip Roofs 70 < θ ≤ 270

Notes:
1. Vertical scale denotes GCP to be used with q h .
2. Horizontal scale denotes effective wind area, in square feet (square
meters).
3. Plus and minus signs signify pressures acting toward and away from the
surfaces, respectively.
4. Each component shall be designed for maximum positive and negative
pressures.
5. Values of GCP for roof overhangs include pressure contributions from
both upper and lower surfaces.
6. For hip roofs with 70 < θ ≤ 270, edge/ridge strips and pressure
coefficients for ridges of gabled roofs shall apply on each hip.
7. For hip roofs with 70 < θ ≤ 250, Zone 3 shall be treated as Zone 2.
8. Notation:
a: 10 percent of least horizontal dimension or 0.4h, whichever is smaller,
but not less than either 4% of least horizontal dimension or 0.9 m.
h: Mean roof height, in meters, except that eave height shall be used for θ
≤ 100.
θ: Angle of plane of roof from horizontal, in degrees.

Figure 6.2.11(c) External pressure coefficients, GCp for components and cladding–Method 2
(h ≤ 18.3 m)

BNBC 2020 Part VI Chapter 2


3162 evsjv‡`k †M‡RU, AwZwi³, †deªæqvwi 11, 2021

Enclosed, Partially Enclosed Buildings: Gable Roofs 270 < θ ≤ 450

Notes:
1. Vertical scale denotes GCP to be used with qh.
2. Horizontal scale denotes effective wind area, in square feet (square
meters).
3. Plus and minus signs signify pressures acting toward and away from the
surfaces, respectively.
4. Each component shall be designed for maximum positive and negative
pressures.
5. Values of GCP for roof overhangs include pressure contributions from
both upper and lower surfaces.
6. Notation:
a: 10 percent of least horizontal dimension or 0.4h, whichever is smaller,
but not less than either 4% of least horizontal dimension or 0.9m.
h: Mean roof height, in meters.
θ: Angle of plane of roof from horizontal, in degrees.
Figure 6.2.11(d) External pressure coefficients, GCp for components and cladding–Method 2
(h ≤ 18.3 m)

BNBC 2020 Part VI Chapter 2


evsjv‡`k †M‡RU, AwZwi³, †deªæqvwi 11, 2021 3163

Enclosed, Partially Enclosed Buildings: Stepped Roofs

Notes:
On the lower level of flat, stepped roofs shown in Figure 6.2.12, the zone
designations and pressure coefficients shown in Figure 6.2.11(b) shall apply,
except that at the roof-upper wall intersection(s), Zone 3 shall be treated as
Zone 2 and Zone 2 shall be treated as Zone 1. Positive values of GCp equal to
those for walls in Figure 6.2.11(a) shall apply on the cross-hatched areas shown
in Figure 6.2.12.
Notation:
b: 1.5h1 in Figure 6.2.12, but not greater than 30.5 m.
h: Mean roof height, in meters.
hi: h1 or h2 in Figure 6.2.12; h 5 h1 + h2; h1≥ 3.1 m; hi/h 5 0.3 to 0.7.
W: Building width in Figure 6.2.12.
Wi: W1 or W2 or W3 in Figure 6.2.12. W5 W1 + W2 or W1 + W2 + W3; Wi/W5
0.25 to 0.75.
e: Angle of plane of roof from horizontal, in degrees.
Figure 6.2.12 External pressure coefficients, GCp for components and cladding–Method 2
(h ≤ 18.3 m)

BNBC 2020 Part VI Chapter 2


3164 evsjv‡`k †M‡RU, AwZwi³, †deªæqvwi 11, 2021

Enclosed, Partially Enclosed Buildings: Multispan Gable Roofs

Notes:
1. Vertical scale denotes GCP to be used with qh.
2. Horizontal scale denotes effective wind area, in square meters.
3. Plus and minus signs signify pressures acting toward and away from the
surfaces, respectively.
4. Each component shall be designed for maximum positive and negative
pressures.
5. For θ ≤ 100 Values of GCP from Figure 6.2.11 shall be used.
6. Notation:
a: 10 percent of least horizontal dimension or 0.4h, whichever is smaller, but
not less than either 4% of least horizontal dimension or 0.9 m.
h: Mean roof height, in feet (meters), except that eave height shall be used for
θ ≤ 100.
W: Building module width, in meters.
θ: Angle of plane of roof from horizontal, in degrees.
Figure 6.2.13 External pressure coefficients, GCp for components and cladding–Method 2
(h ≤ 18.3 m)

BNBC 2020 Part VI Chapter 2


evsjv‡`k †M‡RU, AwZwi³, †deªæqvwi 11, 2021 3165

Enclosed, Partially Enclosed Buildings: Monoslope Roofs 30 < θ ≤ 100z

-3.0

Notes:
1. Vertical scale denotes GCP to be used with qh.
2. Horizontal scale denotes effective wind area A, in square meters.
3. Plus and minus signs signify pressures acting toward and away from the
surfaces, respectively.
4. Each component shall be designed for maximum positive and negative
pressures.
5. For θ ≤ 30 Values of GCP from Figure 6.2.11(b) shall be used.
6. Notation:
a: 10 percent of least horizontal dimension or 0.4h, whichever is smaller,
but not less than either 4% of least horizontal dimension or 0.9 m.
h: Eave height shall be used for θ ≤ 100.
W: Building width, in meters.
θ: Angle of plane of roof from horizontal, in degrees.

Figure 6.2.14(a) External pressure coefficients, GCp for components and cladding–
Method 2 (h ≤ 18.3 m)

BNBC 2020 Part VI Chapter 2


3166 evsjv‡`k †M‡RU, AwZwi³, †deªæqvwi 11, 2021

Enclosed, Partially Enclosed Buildings: Monoslope Roofs 100 < θ ≤ 300

-3.0

Notes:
1. Vertical scale denotes GCP to be used with qh
2. Horizontal scale denotes effective wind area A, in square feet (square
meters).
3. Plus and minus signs signify pressures acting toward and away from the
surfaces, respectively.
4. Each component shall be designed for maximum positive and negative
pressures.
5. Notation:
a: 10 percent of least horizontal dimension or 0.4h, whichever is smaller,
but not less than either 4% of least horizontal dimension or 0.9 m.
h: Mean roof height in meters.
W: Building width, in meters.
θ: Angle of plane of roof from horizontal, in degrees.

Figure 6.2.14(b) External pressure coefficients, GCp for components and cladding–
Method 2 (h ≤ 18.3 m)

BNBC 2020 Part VI Chapter 2