Download as pdf
Download as pdf
You are on page 1of 5
“G Consilium SAL NAVIGATION ANNUAL PERFORMANCE TEST OF CONSILIUM VOYAGE DATA RECORDER Note: Use only capital / block letters if written by hand! ‘Consilumret. no “SAL Navigation ref. no. Inspection dato Qyyy-mm-dd) 9036 2022-01-10 ‘Company ‘American Consulting Group S.A. Por ‘San Lorenzo MO number 9665700 ‘Gress tonnage Keel laid date(yyyy-mmad) 23,803 2011-12-08 Voyage data recorder details ‘VOR model E ‘S-VDR or VOR ‘Main unit serial number That: date yyy) Ft VOR ‘0057442 2012 Fixed capsule model Fixed capsule Serial number | Fixed capsule memory size | Float free serial number LsHvR stat 4Gb NA Alarms - According to MSO.1ICire. 1222-rev. yert an “X"in the field suitable forthe function teste. Pre-existing alarms No alarms ‘Alarms present [Alarms cleared | Note Confirm that no alarms are present on the VOR remote a display when staring the test procedure. a Power supply- According to MSC.1Circ.1222-rev.1 Power Supply model ‘Model WA ‘State Power Supply (PSU) model Only for S-VDRVDR M systems. Power supply alarm ‘Ok | Not ok | Noto Remove extemal power. Confirm that alarm is actvated. x 17:38 Reserve power source Confirm that equipment i stil operating after ‘hour SSminutes, with no additonal alarm /ecors x 19:30 ‘Reserve power source shutdown z Confirm that equipment automaticaly has shut down and stopped recording after atleast 2hours and | Ta minutes. Battery expiry dates- According to MSC. 1/Cir.1222-rev. ower supply battery dato (yyyy-mndd) Tastalation date, Expiry date Note rec powe sup baterysalaton andor expat date, Batis mu aes a oe in oate Page | 1 pou2018 cor Consifium SAL NAVIGATION ANNUAL PERFORMANCE TEST OF CONSILIUM VOYAGE DATA RECORDER Acoustic beacon- According to MSC.11Cite-1222-ev.4. ‘Acoustic beacon functionality oF Natok Note Using manufacturers test equipment confirm that acouslie Beacon functional or by the x 'ubstuton ofa certified fully operational uni. ‘Acoustic beacon version OK NA Note Correct version of acoustic beacon must be mounted on the fxed capsule. Eg. Novega PTS + Proof yellow label) on 2GB/4GB version & Ninety (red label) on 32GB version. | ‘Acoustic beacon battery date (yyyy-mim-aid) Installation date Ey date Note Check battery installation and / or expiration date. Batteries must be in date. 2020-09 2023-09 oK OPT on VOR F2 ‘On-board performance test ‘Ok | Notok | WA” [Note Perform OPT test on RCU to confirm all connections / recording are ok % Overall conaition of equipment. According to MSC.1ICie.1222-e¥.1 Protactive capsules (Fixed) ‘Ok | Notok [WA | Nate Inspect lockielease mechanisms, surface colour, reflective stickers and mounting bolts x Protective capsules (oat free) ‘Ok | Nota] NIA | Note Inspect retease mechanisms, locking bot and mounting bolts on automatic release bracket. x External abies ‘Ok | Notek | Nate Inspect all VOR external cables, shilds and groundings, x ‘Main unit Inspect intemal cables, shields, groundings and mounting bots, x Capsule and LTS recordings Recording on VOR M2 to Ms and S1/Fi Confirm thatthe tems tobe recorded are satisfactory slored for period of atleast f2hours without interruption Recording on VOR F2 CGnfim thatthe tems tobe recorded are salsfactory stored fora period of at east48 hours x without interruption Recording on LTS Confirm thatthe tems tobe recorded are satisfactory stored for period of atleast 90 days x without interuption Notok [NIA [Note x |gI Change or repair of sensors- According to MSC. Circ. 1222-0v.1 Maintenance of VOR ‘Ok | Notok [WA | Neto (Check maintenance records of VOR, x Defects rectified Conti any defects property rected. x Float fee capsule. According to MSC./Ore1222-ev 1, MSC-39(80), MSC.1/Cir. 1040 and SOLAS Regulason 16 9 (Hosni EPIRB Test ‘Ok | Notok [WA [Note Float-troe capsule to be examined and tested in accordance to regulation. See Appendix B x Page |2 apuoie cot @ Consilium SAL NAVIGATION ANNUAL PERFORMANCE TEST OF CONSILIUM VOYAGE DATA RECORDER Interfaces: recording & operation- According to MSC.A/Cie. 1222.4, Date & time Ok [ Notok [WA | Note ‘UTC time information x ‘Ship's position Electronic pestoning system. Longitude / latitude & date x [ ‘Speed (ough water and/or over ground) ‘Ship's designated speed and distance measuring equipment (speed lg). x Heading ‘Ship's gyro compass. rE Bridge audio ‘All bridge microphones. x ‘Communications audio Bridge VHF. x Radar Master radar display o be recorded. (one image every 15 sec) x Radar (second) ‘Second radar, (one image ery 15 $60) x ECDIS ECDIS image shal be recorded for VDR F2 systems, x as" AIS data. x ‘Water depth /Echo sounder ‘Shall include depth below keel Current depth displayed and other status where avaliable, x ‘Main alarms® ‘All mandatory alarms on bridge. x ‘Rudder order and response ™ ‘Steering gear and autopic x Engine order and responce: Telographs, contols and thrusters. x Hill openings status" ‘All mandatory status information displayed on bridge. x Watertight and fire door status © ‘Al mandatory status information displayed on bridge. x ‘ecoleration and hull stresses” Hull stress & response monitoring equipment x Wind speed and direction ‘Anemometer, relatve or true wind speed and direction may be recorded. x Rolling motion Inclinometer shal be recorded x Electronic logbook The electronic lagbcok shall be recorded. x {Only mandatory to be recorded on a VOR F2 system 2 On S-VDR If not possible to record or no interface avalable off the shelf for Radar, confirm that AIS i recorded ® Shall only be recorded on S-VDRIT avaliable as NMEA. It's mandatory for all VOR systems. See IEC 61995-ed.2.0 ‘Annex B, Table B.1 for mare details * Shall only be recorded if ited and available as NMEA Page |3 aro et & Consilium a) SAL NAVIGATION ANNUAL PERFORMANCE TEST OF CONSILIUM VOYAGE DATA RECORDER ‘Notes, Please remember that notes shail also be included on the service report. NL “This performance test was conducted in accordance with SOLAS regulation V18.8 and forms part of the procedure for the issue of the Annual Performance Test Certificate, The results, information and any comments should be relayed to the manufacturer in accordance with the instructions contained within the Operation Manual. Subject to satisfactory results, an Annual Performance Test Certificate will then be issued. In accordance with the principles of harmonization of Certificates, the Certificate, when issued, will remain valid unti the next ~annualre-validation of that Certificate, subject to the equipment being maintained in appropriate operational condition. a Te WD EOD By CONSID WARNE SATETY HERE CO aa eee Ceneaebtt scAN | S gy. < MV.J— PIONEER 4 ration BND Owe S Maer ssc eetaeyn) | ‘Signature of person authorized by Consilium | Signature of vessel representative Page |4 penoie eo i/ / & Consilium @ SAL NAVIGATION f APPENDIX A The following annex is only to ensure functionality and reliability ofthe Voyage Data Recorder. The below checks are not mandatory and will not affect the approval ofthe annual performance test BIOS & Firmware updatefor S-VOR/VDR $1, Ft & F2 cma ~[ROUE Prosap Oi ver Newer ‘Older Newer Old ver Newer 10 sasosts OK Nota [Wa OE Natok [WA ok Natok [Wk x x x Software update for S-VDRNVOR S1, F1 & F2 waz ROW [Pree Cis ver Newer Over Newver Older Newer B10 6410616, OK Notok [WA OF AD ee Natok [WA x x x Tae aT ven Old ver Newer Older Newer Od ver Newer a ee x x x VOR investigator's kt Investigator Kit avalaity OK Natok WK YVR installed on orate st of June 2008 shoud have a ssiod : Invstgatrsikeavalte on boar an placed ade VOR abrat : Flat fee Capsule Tron40 functionality Silcone grease ox WA Note Set water can cause communication problem between docking ard soraye mode Preven : water gress by apy scone esse Deteen doc an storage Revie Poston Confer EPIRB i seated corey in backelNo gap shoul be ve belweendodkng and z Storage module Backup Backup felon OK NatoK Conf backup funeion sworn. To USE fora, FIST and FE f ToDVD-Ram/ BMD‘ for Ma MS MBLs sete. | Down Download APY data OK Natok Dowload the APT dala om the capsule al shallbe submited e Consilum Marine & Safety AB, arizo1 — eo1 Page | |

You might also like