Professional Documents
Culture Documents
2021 - Flow Measurement in Canals Using Trapezoidal Flumes With Cylindrical Piers - IJSWR - Volume 52 - Issue 5 - Pages 1193-1207
2021 - Flow Measurement in Canals Using Trapezoidal Flumes With Cylindrical Piers - IJSWR - Volume 52 - Issue 5 - Pages 1193-1207
2021 - Flow Measurement in Canals Using Trapezoidal Flumes With Cylindrical Piers - IJSWR - Volume 52 - Issue 5 - Pages 1193-1207
ABSTRACT
Due to the high cost and the need for Experts to use advanced flow measuring equipment in canals, the use of
simple, inexpensive and low-cost methods has always been considered by researchers and operating companies
of irrigation and drainage networks. In this study, flow measurement in canals has been investigated
experimentally using trapezoidal flumes with cylindrical pier in four side slopes. By measuring the flow depth
at upstream and downstream of the flume throat, separate relationships and graphs were obtained to calculate
the discharge at each studied side slopes on the base of functional relationships (both in free and submerged
flow conditions). Also for the studied side slopes, one relation for free flow conditions and two relations for
submerged flow conditions were obtained. Mean absolute relative error (MARE) for calculation of
dimentionaless discharge using the obtained relationships under free flow conditions was obtained 6.2, 4.6, 8.1
and 9.4%, and under submerged flow conditions was obtained 25.17, 22.9, 19 and 14% respectively in side
slopes (z) of 1, 0.7, 0.4663 and 0.268. The value of MARE for calculation of dimensionless discharge using the
obtained relation for all studied side slopes was obtained 8.2% under free flow conditions and 35.9 and 34.3%
under submerged flow conditions (using two related equations). The maximum root mean square error (RMSE)
for calculation of dimensionless discharge for the all studied side slopes, was obtained 0.078 under free flow
conditions and 0.34 and 0.38 under submerged flow conditions (using two related equations). Then, using the
related relation to each side slope (separately) has less error compared to using a relation for all side slopes.
Keywords: Free Flow, Submerged Flow, Trapezoidal Canals, Cylindrical Piers, Dimensional Analysis.
چکيده
بدلیل هزینهبر بودن و احتیاج به نیروی متخصص جهت بهرهبرداری از تجهیزات پیشرفته اندازهگیری جریان در کانالها،
استفاده از روشهای ساده ،ارزان و کمهزینه همواره مورد توجه محققین و شرکتهای بهرهبرداری از شبکههای آبیاری و
زهکشی بوده است .در این پژوهش اندازهگیری جریان در کانالها با استفاده از فلومهای ذوزنقهای با پایههای استوانهای ،به
صورت آزمایشگاهی در چهار شیب جانبی بررسی شده است .با اندازهگیری عمق جریان در باالدست و پاییندست گلوگاه
فلوم و بر اساس روابط تابعی ،یک رابطه و نمودار جداگانه برای محاسبه دبی جریان در هر شیبهای جانبی بررسی شده
بدست آمد (هم در شرایط جریان آزاد و هم در شرایط جریان مستغرق) .همچنین برای تمام شیبهای جانبی بررسی شده
ی ک رابطه برای شرایط جریان آزاد و دو رابطه برای شرایط جریان مستغرق بدست آمد .میانگین قدرمطلق خطای نسبی
) (MAREبرای محاسبه دبی بیبعد در شرایط جریان آزاد در شیبهای جانبی ) 0/4663 ،0/7 ،1 (zو 0/268به ترتیب
8/1 ،4/6 ،6/2و 9/4و در شرایط جریان مستغرق در شیبهای جانبی مذکور به ترتیب 19 ،22/9 ،25/17و 14/9درصد
برآورد شده است .مقدار این پارامتر آماری برای محاسبه دبی بیبعد بر اساس رابطه بدست آمده در شرایط جریان آزاد (یک
رابطه برای تمام شیبهای جانبی بررسی شده) برابر با 8/2درصد و در شرایط جریان مستغرق (با استفاده از دو رابطه در
نظر گرفته شده) 35/9 ،و 34/3درصد محاسبه شدند .در بین شیبهای جانبی بررسی شده حداکثر مقدار خطای جذر
میانگین مربعات ) (RMSEبرای محاسبه دبی بیبعد در شرایط جریان آزاد 0/078و در شرایط جریان مستغرق(با استفاده
از دو رابطه در نظر گرفته شده) 0/34 ،و 0/38است .بنابراین استفاده از رابطه مربوط به هر شیب جانبی (رابطهای که بطور
جداگانه برای هر شیب جانبی بدست آمده است) دارای خطای کمتری نسبت به استفاده از یک رابطه برای تمام شیبهای
جانبی بررسی شده است.
واژههای کليدی :جریان آزاد ،جریان مستغرق ،کانالهای ذوزنقهای ،پایههای استوانهای ،آنالیز ابعادی.
پایهای استوانهای شکل در محور مرکزی کف کانال ذوزنقهای، پایین افتادگی کف مجرای جریان و یا ترکیبی از آنها بوجود
مقطع تنگ شده (گلوگاه) ایجاد میشود .این محققین پس از میآید .تحقیقات وسیعی در رابطه با چگونگی ایجاد تنگشدگی
انجام آزمایشهای متعدد ،رابطهای برای محاسبه جریان بدست مقطع جریان ،برآمدگی و پایین افتادگی کف مجرا و ترکیبی از
آوردند و اعالم نمودند که این رابطه را تا درجه استغراق 80درصد آنها توسط محققین انجام گرفته که منجر به ارائه انواع فلومها و
میتوان بکار برد رابطۀ مذکور ارتباط بین عمق جریان بیبعد و روابط و نمودارهای مربوطه شده است .از اولین تحقیقات انجام
دبی جریان بیبعد میباشد .در رابطه ارائه شده توسط این گرفته در رابطه با فلومها میتوان به تحقیقات بالنگر (Belanger,
محققین تاثیر درجه استغراق در نظر گرفته نشده است. ) ،1849بازین ) ،(Bazin, 1896پارشال ) (Parshal 1900و بالوفت
) Peruginelli and Bonacci (1997با ایجاد یک مقطع ) (Balloffet 1951اشاره نمود) .(Boss 1985در سالهای اخیر
کنترل با نصب کردن پایه منشوری در محور مرکزی کف کانال مطالعات متعددی درباره ایجاد مقطع کنترل جریان صرفا با تنگ
مستطیلی رابطه ای بین دبی و عمق جریان را با استفاده از رابطه کردن مقطع جریان و در نتیجه ایجاد گلوگاه صورت گرفته است.
عدد فرود در شرایط جریان آزاد و مستغرق بدست آوردند .آنها ) Hager (1985برای ایجاد تنگشدگی (گلوگاه) در
خطای محاسبه دبی جریان را با استفاده از رابطه بدست آمده سه کانالهای مستطیلی ،پایههای استوانهای را در محور مرکزی کف
درصد اعالم کردند. این کانالها نصب و پس از انجام آزمایشهایی رابطه محاسبه دبی
) Samani and Magallanez (2000فلوم موسوم به فلوم S- جریان را بدست آورد و خطای محاسبه دبی جریان با استفاده از
Mرا برای اندازهگیری جریان در کانالها معرفی نمودند .در این رابطه ارائه شده را 5درصد اعالم نمود .همچنین وی از این روش
فلومها با نصب دو نیم استوانه روبروی هم در دو طرف مقطع برای ایجاد گلوگاه در کانالهای ذوزنقهای استفاده نمود و منحنی
مستطیلی ،مقطع کنترل جریان ایجاد شده است .آنها معادله تعیین دبی جریان را ارائه کرد .این منحنی رابطه بین عمق جریان
محاسبه دبی جریان را بر اساس آنالیز ابعادی بدست آورند. بیبعد ( )) zy/(B-dودبی جریان بدون بعد()) Qz1.5/(g0.5(B-d)2.5
) Baiamonte and Ferro (2007نیز با انجام آزمایشهای متعدد میباشد که zشیب وجه جانبی کانال y ،عمق جریان باالدست
روی این فلوم توانستند معادله محاسبه دبی جریان را با استفاده گلوگاه B ،عرض کف کانال d ،قطر پایه استوانهای g ،شتاب ثقل
از آنالیز ابعادی و نظریه خود تشابه ناقص 1بدست آورند .به همین زمین و Qدبی جریان است.
دلیل این فلوم به فلوم SMBF2معروف شد. برای ایجاد گلوگاه Hager (1986) ،پایههای مخروطی را در
در تحقیقات ) Matter et al. (2017فلوم قابل حمل نیم محور مرکزی کف کانالهای مستطیلی نصب و آزمایشهایی را
دایرهای 3معرفی شد .در این فلوم مقطع کنترل جریان (گلوگاه) با انجام داد .وی بسته به اینکه مقدار انرژی مخصوص بیبعد (
با نصب پایه استوانهای شکل در محور مرکزی کف کانال نیم ) ) E*=zE/(B-dبزرگتر مساوی یک و مابین صفر و یک باشد دو
دایرهای ایجاد شده و عمق بحرانی در این مقطع تشکیل میگردد. رابطه برای محاسبه دبی بدست آورد.
این محققین با استفاده از معادالت انرژی مخصوص و عدد فرود، ) Hager (1988در کانالهای دایرهای نیز برای ایجاد
بر اساس نتایج آزمایشها رابطه محاسبه دبی جریان و رابطه گلوگاه ،از پایههای استوانهای استفاده نمود و با استفاده از مفهوم
محاسبه ضریب دبی جریان را بدست آورده و مقدار خطا در انرژی مخصوص و رابطه عدد فرود ،رابطه محاسبه دبی جریان را
محاسبه دبی جریان را حداکثر 8/7درصد گزارش نمودند (شکل ارائه کرد.
1الف). فلوم قابل حمل دایرهای که در آن برای ایجاد تنگشدگی
تنگشدگی مقطع جریان با نصب دو نیم پایه منشوری به از نصب پایهای استوانهای در وسط مقطع دایرهای استفاده شده،
صورت روبرو در دو طرف کانال مستطیلی توسط )Goel (2006 توسط ) Samani and Magallanez (1992برای اندازهگیری دبی
مورد آزمایش قرارگرفت (شکل 1ب) .عرض مقطع تنگ شده جریان در کانالها استفاده شد .معادله بدست آمده در تحقیق این
نصف عرض کف کانال در نظر گرفته شده است .تحقیقات ایشان محققین با استفاده از مفهوم اصل انرژی و آنالیز ابعادی بدست
منجر به ارائه رابطهای شد که برای محاسبه دبی جریان هم برای آمده است.
شرایط جریان آزاد و هم برای شرایط جریان مستغرق بکار میرود. ) Samani and Magallanez (1993فلومهای ذوزنقهای با
وی در جریان مستغرق منحنی تغییرات ضریب دبی جریان در پایههای استوانهای را معرفی نمودند .در این فلومها با قرار دادن
3 1
Semicircular Mobile Flume Incomplete Self-Similarity
2 Samani, Magallanez, Baiamonte, Ferro
1196تحقيقات آب و خاک ايران ،دوره ،52شماره ،5مرداد ( 1400علمی – پژوهشی)
میشود. برابر درجه استغراق و در جریان آزاد تغییرات ضریب دبی جریان
) ،Hayawi et al. (2013با نصب دو مثلث با زاویه راس 2 در برابر نسبت عمق جریان در باالدست گلوگاه به طول گلوگاه را
به صورت روبرو در طرفین یک مجرای مستطیلی و در نتیجه ایجاد ارائه نمود.
تنگشدگی ،مقطع کنترل جهت اندازهگیری دبی جریان را ایجاد ) Das et al. (2017با انجام آزمایشهایی روی فلوم گلوکوتاه
و رابطه محاسبه دبی جریان را بدست آورد (شکل 1د) .در (گلو بریده )1با عرض 0/127متر ( 5اینچ) که طبق اظهارات آن
تحقیقات آنها پارامترهای زاویه راس مثلثها ) ،(نسبت ها فلوم گل و کوتاه با این عرض کمتر مورد توجه قرار گرفته،
تنگشدگی ) (Bc/Bو شیب کف به عنوان متغیر در نظر گرفته معادالت جدیدی را برای محاسبه دبی جریان در شرایط جریان
شدند .نتایج تحقیقاتشان نشان داد که ضریب دبی جریان با شیب آزاد و مستغرق بدست آوردند .خطای محاسبه دبی با استفاده از
طولی کانال و نسبت تنگشدگی رابطه مستقیم دارد .همچنین معادله مربوطه حداکثر 5درصد گزارش شده است (شکل 1ج).
در یک نسبت تنگشدگی ثابت ،ضریب دبی جریان با زاویه نیز معادله محاسبه دبی جریان در شرایط جریان آزاد Q=0.344h1.695
متناسب است. است که hعمق جریان در باالدست گلوگاه است که توسط
چاهکی که در فاصلهای مشخص از گلوگاه قرار دارد اندازهگیری
ب الف
د ج
شکل -1تنگشدگی مقطع جريان ،الف Mattar et al (2017) .ب Goel (2006) .ج Das et al. (2017) .دHayawi et al. (2013) .
رابطهای برای محاسبه دبی جریان در کانالهای ذوزنقهای با شیب ) Rashwan and Idress (2013اندازهگیری جریان در
جانبی ( 1:1بجز رابطه ارائه شده توسط محقق مربوطه) را بدست کانالهای دایرهای نیمهپر ) (partially filledبا استفاده از
آورند .این محققین متوسط خطا و خطای استاندارد محاسبه دبی فلومهای دایره ای قابل حمل را بررسی نموده و رابطه محاسبه
جریان با استفاده از رابطه بدست آمده را به ترتیب 4/7و 5/34 ضریب دبی جریان را که به نسبت تنگشدگی و انرژی مخصوص
درصد و با استفاده از رابطه بدست آمده توسط Samani and بیبعد وابسته است ،بدست آوردند.
) Magallanez (1993را 5/1و 14/68درصد اعالم نمودند. ) Badar and Ghare (2012با استفاده از دادههای
) Ghare and Badar (2014با نصب پایههای استوانهای در آزمایشگاهی بدست آمده از تحقیقات Samani and Magallanez
محور مرکزی کف کانالهای مستطیلی ،با ایجاد مقطع تنگ شده، )( (1993که فلومهای ذوزنقهای با پایههای استوانهای را بررسی
آزمایشهایی را در شرایط جریان آزاد جهت بدست آوردن رابطه کردهاند) ،گروههای مختلف بدون بعد دبی و اشل را بررسی و
شیب وجه جانبی 1:1هم برای شرایط جریان آزاد و هم برای اندازهگیری دبی جریان انجام و دو رابطه برای محاسبه دبی جریان
شرایط جریان مستغرق ارائه شده بدون اینکه تاثیر درجه استغراق را بدست آورند .رابطه اول نسبت دبی تئوریک به دبی واقعی
در رابطه مذکور در نظر گرفته شود .همچنین در رابطه ارائه شده (همان ضریب دبی جریان) است و رابطه دوم با استفاده از آنالیز
توسط ) Ghare and Badar (2012که بر اساس دادههای رگرسیونی بین دو پارامتر بدون بعد دبی بیبعد و عمق جریان
آزمایشگاهی محققین دیگر از جمله Samani and Magallanez بیبعد بدست آمده است .این محققین حداکثر خطای محاسبه
) (1993استخراج شده نیز اثر درجه استغراق دیده نمیشود و این دبی با استفاده از این دو رابطه را به ترتیب 5و 20درصد اعالم
رابطه صرفا برای شیب جانبی 45درجه بدست آمده است .در این نمودند.
تحقیق سعی شده با نصب پایههای استوانهای در محور مرکزی قابلیت فلومهای گلوکوتاه در بدست آوردن دبی جریان فوق
کف کانالهای ذوزنقهای و در نتیجه ایجاد مقطع تنگ شده بحرانی توسط ) Tekade et al. (2016بررسی شد .آنها با توجه
(گلوگاه) ،روابط محاسبه دبی جریان هم در شرایط جریان آزاد و به وجود همبستگی باال بین دبی جریان و عمق جریان در باالدست
هم در شرایط جریان مستغرق با در نظر گرفتن تاثیر درجه گلوگاه فلوم ،رابطه بدست آمده برای محاسبه دبی جریان را
استغراق پس از انجام آزمایشهای متعدد به صورت جداگانه مناسب دانستند Kapoor et al. (2019) .بر اساس مفهوم انرژی،
بدست آیند. جریان اطراف پایههای مخروطی نصب شده در محور مرکزی کف
کانال مستطیلی را بررسی نموده و رابطه ارائه شده برای محاسبه
مواد و روشها دبی جریان را در چندین فلوم آزمایشگاهی مورد ارزیابی قرار
آناليز ابعادی دادند .حداکثر خطا در محاسبه دبی جریان را 9درصد گزارش
در صورتی که متغیرهای مؤثر در یک پدیده فیزیکی شناخته شده نمودند.
باشند اما ارتباط بین آنها معلوم نباشد ،با استفاده از آنالیز ابعادی ) Mohammadi and Vatankhah (2020شکل جدیدی از
میتوان پدیده را به صورت رابطهای بین چند گروه بیبعد که فلومهای اندازهگیری جریان را که دارای دیوارههای مخروطی و
تعدادشان کمتر از تعداد متغیرها است فرموله کرد .به این ترتیب استوانهای هستند و تاج آنها منطبق بر کف کانال مستطیلی است
تعداد آزمایشهای الزم برای تعیین رابطه بین متغیرها کمتر شده معرفی نمودند .این محققین ضمن اعالم اینکه که در این سازه
و غالباً نوع آزمایشها نیز سادهتر میشود .پارامترهای موثر در میزان افت انرزی و پسزدگی جریان ناچیز است ،معادالتی را برای
اندازهگیری دبی جریان در این پژوهش به صورت روابط تابعی زیر تخمین دبی در شرایط جریان آزاد با استفاده از آنالیز ابعادی
میباشند. بدست آوردند .خطای محاسبه دبی جریان با استفاده از رابطه
الف :جریان آزاد مربوط به فلوم با دیوارههای استوانهای 2/72و برای فلوم با
در این شرایط عوامل موثر در جریان در رابطه تابعی ( )1ارائه دیوارهای مخروطی 1/85درصد گزارش شده است .آنها
شدهاند. همچنین یک رابطه کلی که هم برای فلوم با دیوارههای مخروطی
(رابطه )1 و هم برای فلوم با دیوارههای استوانهای استفاده میشود بدست
f Q, y1 .g, B, d , z, , , 0 آوردند .مقدار خطای ابن رابطه در برآورد دبی جریان 3/09درصد
که در آن Qدبی جریان y1 ،عمق جریان در باالدست پایه، اعالم شده است.
gشتاب ثقل زمین B ،عرض کف کانال d ،قطر پایه استوانهایz ، با توجه به بررسیهای صورت گرفته در رابطه با تحقیقات
شیب وجه جانبی کانال ،جرم حجمی آب ،ویسکوزیته محققین مختلف ،مشخص میشود که اکثر محققین سعی در
دینامیک آب و σضریب نیروی کشش سطحی است. بدست آوردن رابطه محاسبه دبی جریان با استفاده از ایجاد
با در نظر گرفتن Bc=B-d+2zy1رابطه تابعی ( )1را به تنگشدگی عرضی در کانالهایی با مقاطع عرضی مختلف
صورت رابطه تابعی ( )2نیز میتوان نوشت. نمودهاند .اما با توجه به اینکه مقطع اکثر کانالهای آبیاری و
f Q, y1 .g , Bc , , , 0 (رابطه )2 آبرسانی به شکل ذوزنقهای طراحی و ساخته میشوند لذا
بر اساس تئوری باکینگهام ،با در نظر گرفتن متغیرهای ،Bc اندازهگیری جریان در این کانالها با استفاده از روشهای ساده و
gو به عنوان متغیرهای تکرار شونده ،پارامترهای بیبعد زیر ارزان قیمت از اهمیت باالیی برخوردار است .رابطه ارائه شده
بدست میآیند. توسط ) Samani and Magallanez (1993همانطوریکه پیشتر
بیان گردید برای محاسبه دبی جریان در فلومهای ذوزنقهای با
1198تحقيقات آب و خاک ايران ،دوره ،52شماره ،5مرداد ( 1400علمی – پژوهشی)
Q y1
کف قابل تنظیم) به عرض کف 46سانتیمتر و طول 6متر و ارتفاع 1 , 2 , 3 Re , 4 We ()3
gBc5 Bc
70سانتیمتر طراحی و ساخته شد و آزمایشها در این کانال
آزمایشگاهی انجام گردید .کف کانال از جنس ورق آهن گالوانیزه پس از حذف پارامترهای بیبعد بدون تاثیر عدد رینولدز
و دیوارههای آن از شیشه با چارچوب آهنی ساخته شده است. ) (Reو عدد وبر ) ،(Weرابطه تابعی بدون بعد ( )4بدست میآید.
کنترل سطح آب در کانال توسط یک دریچه که در انتهای کانال Q y (رابطه )4
f 1
نصب شده صورت میگرفت .برای اندازهگیری عمق جریان از عمق gBc5 Bc
سنجی با دقت ± 0/1میلیمتر استفاده شد .شیب کف فلوم توسط رابطه ( )5مبنای محاسبات در شرایط جریان آزاد در نظر
یک جک مکانیکی که در زیر آن قرار دارد قابل تنظیم بوده و دبی b گرفته شد.
Q y1
جریان به روش حجمی توسط مخزنی که در انتهای فلوم قرار داده a (رابطه )5
gBc5 Bc
شده قابل اندازهگیری است .شکل ( )2این فلوم را حین انجام
آزمایش نشان میدهد .در این تحقیق از چهار پایه استوانهای با ب :جریان مستغرق
قطرهای 38 ،40 ،42و 36سانتیمتر از جنس ورق آهن گالوانیزه، عوامل موثر در شرایط جریان مستغرق به صورت رابطه ()6
استفاده شده است. میباشند.
نحوه انجام آزمايشها f Q, y1 , yt , g , B, d , z, , , 0 (رابطه )6
(z=0.268 آزمایشها در چهار شیب جانبی صورت گرفتند و یا
))◦ (=75◦), 0.466 (=65◦), 0.7 (=55◦), 1 (=45که زاویه f Q, y1 , yt , g , Bc , , , 0 (رابطه )7
وجه جانبی کانال با افق میباشد .پس از تنظیم کانال در شیب که ytعمق پایاب است.
جانبی مورد نظر و نصب یکی از پایههای استوانهای در محور طبق تئوری باکینگهام پارامترهای بیبعد زیر بدست
مرکزی کف کانال و برقراری جریان درکانال ،پارامترهای مهم و میآیند.
مورد نیاز یعنی عمق جریان در باالدست و پایین دست پایه ( y1و (رابطه )8
Q y1 y
)ytو دبی جریان ( )Qدر شرایطی که دریچه کنترل سطح آب 1 , 2 , 3 t , 4 Re , 5 We
gB 5
c
Bc Bc
کامال باز است اندازهگیری شدند .سپس بدون تغییر دبی جریان
پس از حذف پارامترهای بیبعد بدون تاثیر ) (Re , Weو
حداقل دو و حداکثر سه درجه استغراق )( (yt/y1بسته به دبی
پس از تقسیم y1/Bcبه yt/Bcرابطه تابعی ( )9برای این شرایط
جریان) با تنظیم دریچه انتهایی ایجاد و پارامترهای مورد نیاز در
در نظر گرفته شد.
هر درجه استغراق اندازهگیری شدند .آزمایشهای فوق برای شش Q Bc y1
f , (رابطه )9
دبی جریان انجام شدند .پس در یک شیب جانبی معین 24 gyt 5
t t
y y
آزمایش در شرایط جریان آزاد ( 6آزمایش برای یک پایه
پس از بررسیهای متعدد روی روابط غیر خطی و گروههای
استوانهای) و 48آزمایش (حداقل) در شرایط جریان مستغرق
بدون بعد مختلف ،رابطه ( )10بر اساس رابطه ( ،)9به عنوان مبنای
انجام شد .پس از اتمام آزمایشهای فوق ،شیب جانبی کانال روی
انجام محاسبات در شرایط جریان مستغرق مد نظر قرار گرفت.
مقدار مورد نظر بعدی تنظیم و تمامی آزمایشهای مذکور ،در 2
Q B y B y
شیب جانبی جدید تکرار شدند. (رابطه a c 1 b c 1 c )10
برای بررسی دقت نمودارها و روابط بدست آمده ،از gyt5 yt yt yt yt
پارامترهای آماری میانگین قدرمطلق خطای نسبی) (MAREو همچنین در این شرایط عالوه بر رابطه ( ،)10تغییرات بین
خطای جذر میانگین مربعات ) (RMSEاستفاده شده است .پارامتر دو پارامتر بیبعد نسبت استغراق ) (yt/y1در برابر دبی بیبعد در
مذکور در روابط ( )12و ( )13نشان داده شدهاند. هر شیب جانبی طبق رابطه ( )11نیز بررسی شد.
1 n xi y i
MARE (رابطه )12 b
n i 1 xi Q y
a t (رابطه )11
n
gyt5 y1
x i yi
2
تجهيزات آزمايشگاهی
RMSE i 1
(رابطه )13
n برای انجام این تحقیق ،کانال آزمایشگاهی (با شیب جانبی و شیب
وليزادگان و اقدسی :اندازهگيری جريان در کانالها با استفاده از 1199 ... (علمی – پژوهشی)
آزمایشها در جدول ( )1و دادههای آزمایشگاهی در جدولهای که در آن xiو yiبه ترتیب مقادیر آزمایشگاهی و محاسباتی
( )2و ( )3ارائه شده است .در این جدول اندیسهای 1و 2به متغیر مورد نظر است.
ترتیب مربوط به مقاطع باالدست و پاییندست گلوگاه است. بر اساس دادههای اندازهگیری شده ،محدوده متغیرهای موثر در
z=0.4663 z=0.268
)B(m )d(m )y1(m Q )B(m )d(m )y1(m Q
0.46 0.42 0.03 0.00042759 0.46 0.36 0.04 0.000498464
0.46 0.42 0.046 0.00106798 0.46 0.36 0.058 0.00247092
0.46 0.42 0.061 0.0017629 0.46 0.36 0.068 0.003392
0.46 0.42 0.075 0.0030183 0.46 0.36 0.073 0.003878063
0.46 0.42 0.085 0.003345 0.46 0.36 0.08 0.00473749
0.46 0.42 0.092 0.00432 0.46 0.36 0.087 0.00505386
0.46 0.4 0.047 0.001255282 0.46 0.38 0.05 0.00173291
0.46 0.4 0.052 0.0015481 0.46 0.38 0.056 0.00198887
0.46 0.4 0.056 0.0018868 0.46 0.38 0.07 0.00313727
0.46 0.4 0.065 0.0024609 0.46 0.38 0.075 0.003435815
0.46 0.4 0.085 0.00394295 0.46 0.38 0.085 0.0044883
0.46 0.4 0.09 0.005225805 0.46 0.4 0.033 0.000582832
0.46 0.38 0.044 0.001580006 0.46 0.4 0.058 0.0016578
0.46 0.38 0.054 0.002379346 0.46 0.4 0.065 0.0020238
0.46 0.38 0.06 0.00303113 0.46 0.4 0.08 0.00298059
0.46 0.38 0.066 0.0034263 0.46 0.4 0.095 0.0045324
0.46 0.38 0.072 0.004304753 0.46 0.4 0.1 0.0050086
0.46 0.38 0.08 0.005136486 0.46 0.42 0.032 0.000369132
0.46 0.36 0.026 0.000557269 0.46 0.42 0.063 0.001393155
0.46 0.36 0.045 0.0016786 0.46 0.42 0.079 0.002285261
0.46 0.36 0.054 0.00265539 0.46 0.42 0.091 0.003256281
0.46 0.36 0.061 0.0032598 0.46 0.42 0.1 0.004020164
0.46 0.36 0.066 0.004080283 0.46 0.42 0.105 0.0042346
0.46 0.36 0.075 0.00480445
1200تحقيقات آب و خاک ايران ،دوره ،52شماره ،5مرداد ( 1400علمی – پژوهشی)
جدول -3دادههای آزمايشگاهی در شرايط جريان مستغرق در شيبهای جانبی z=0.7و z=1
z=1 z=0.7
)B(m )d(m )y1(m )yt(m )Q(m3/s )B(m )d(m )y1(m )yt(m )Q(m3/s
0.46 0.42 0.05 0.022 0.0017249 0.46 0.42 0.037 0.02 0.000845
0.46 0.42 0.052 0.035 0.0017249 0.46 0.42 0.041 0.034 0.000845
0.46 0.42 0.058 0.045 0.0017249 0.46 0.42 0.052 0.038 0.001737
0.46 0.42 0.057 0.03 0.0022118 0.46 0.42 0.053 0.039 0.001737
0.46 0.42 0.06 0.045 0.0022118 0.46 0.42 0.056 0.048 0.001737
0.46 0.42 0.07 0.058 0.0022118 0.46 0.42 0.06 0.045 0.002359
0.46 0.42 0.069 0.045 0.0030462 0.46 0.42 0.062 0.047 0.002359
0.46 0.42 0.072 0.06 0.0030462 0.46 0.42 0.065 0.059 0.002359
0.46 0.42 0.08 0.069 0.0030462 0.46 0.42 0.07 0.056 0.003265
0.46 0.42 0.07 0.035 0.0037240 0.46 0.42 0.072 0.058 0.003265
0.46 0.42 0.072 0.05 0.0037240 0.46 0.42 0.075 0.07 0.003265
0.46 0.42 0.085 0.073 0.0037240 0.46 0.42 0.078 0.062 0.00397
0.46 0.42 0.075 0.035 0.0043997 0.46 0.42 0.079 0.064 0.00397
0.46 0.42 0.08 0.06 0.0043997 0.46 0.42 0.085 0.077 0.00397
0.46 0.42 0.095 0.084 0.0043997 0.46 0.42 0.085 0.07 0.004796
0.46 0.42 0.081 0.04 0.0049584 0.46 0.42 0.086 0.073 0.004796
0.46 0.42 0.089 0.055 0.0049584 0.46 0.42 0.087 0.081 0.004796
0.46 0.42 0.095 0.085 0.0049584 0.46 0.4 0.03 0.012 0.000774
0.46 0.4 0.051 0.027 0.0022610 0.46 0.4 0.033 0.016 0.000774
0.46 0.4 0.06 0.037 0.0022610 0.46 0.4 0.044 0.027 0.001428
0.46 0.4 0.069 0.053 0.0022610 0.46 0.4 0.045 0.028 0.001428
0.46 0.4 0.056 0.033 0.0024030 0.46 0.4 0.046 0.038 0.001428
0.46 0.4 0.07 0.049 0.0024030 0.46 0.4 0.053 0.037 0.00225
0.46 0.4 0.08 0.067 0.0024030 0.46 0.4 0.054 0.041 0.00225
0.46 0.4 0.068 0.043 0.0027910 0.46 0.4 0.06 0.053 0.00225
0.46 0.4 0.076 0.055 0.0027910 0.46 0.4 0.059 0.044 0.002631
0.46 0.4 0.085 0.07 0.0027910 0.46 0.4 0.060 0.046 0.002631
0.46 0.4 0.065 0.04 0.0033560 0.46 0.4 0.065 0.058 0.002631
0.46 0.4 0.07 0.05 0.0033560 0.46 0.4 0.068 0.054 0.003623
0.46 0.4 0.082 0.07 0.0033560 0.46 0.4 0.069 0.056 0.003623
0.46 0.4 0.066 0.04 0.0038760 0.46 0.4 0.08 0.075 0.003623
0.46 0.4 0.075 0.054 0.0038760 0.46 0.4 0.077 0.063 0.004683
0.46 0.4 0.087 0.076 0.0038760 0.46 0.4 0.078 0.064 0.004683
0.46 0.4 0.075 0.049 0.0044330 0.46 0.4 0.11 0.105 0.004683
0.46 0.4 0.08 0.059 0.0044330 0.46 0.38 0.039 0.019 0.001259322
0.46 0.4 0.1 0.089 0.0044330 0.46 0.38 0.04 0.025 0.001259322
0.46 0.38 0.07 0.048 0.0020046 0.46 0.38 0.045 0.035 0.001259322
0.46 0.38 0.08 0.061 0.0020046 0.46 0.38 0.05 0.025 0.002142591
0.46 0.38 0.085 0.065 0.0025059 0.46 0.38 0.051 0.03 0.002142591
0.46 0.38 0.065 0.04 0.0030382 0.46 0.38 0.052 0.04 0.002142591
0.46 0.38 0.075 0.053 0.0030382 0.46 0.38 0.055 0.025 0.0024148
0.46 0.38 0.087 0.069 0.0030382 0.46 0.38 0.056 0.03 0.0024148
0.46 0.38 0.066 0.04 0.0036360 0.46 0.38 0.057 0.04 0.0024148
0.46 0.38 0.07 0.047 0.0036360 0.46 0.38 0.062 0.03 0.00322388
0.46 0.38 0.082 0.065 0.0036360 0.46 0.38 0.063 0.04 0.00322388
0.46 0.38 0.075 0.044 0.0051646 0.46 0.38 0.075 0.065 0.00322388
0.46 0.38 0.08 0.057 0.0051646 0.46 0.38 0.069 0.035 0.00387588
0.46 0.38 0.1 0.085 0.0051646 0.46 0.38 0.07 0.04 0.00387588
0.46 0.36 0.055 0.045 0.0015982 0.46 0.38 0.071 0.055 0.00387588
0.46 0.36 0.065 0.059 0.0015982 0.46 0.38 0.075 0.05 0.00451666
0.46 0.36 0.06 0.042 0.0020335 0.46 0.38 0.078 0.06 0.00451666
0.46 0.36 0.07 0.059 0.0020335 0.46 0.38 0.08 0.07 0.00451666
0.46 0.36 0.084 0.078 0.0020335 0.46 0.36 0.038 0.018 0.0012257
0.46 0.36 0.055 0.039 0.0025080 0.46 0.36 0.04 0.028 0.0012257
0.46 0.36 0.073 0.06 0.0025080 0.46 0.36 0.044 0.035 0.0012257
0.46 0.36 0.085 0.079 0.0025080 0.46 0.36 0.058 0.035 0.0025016
0.46 0.36 0.06 0.048 0.0030848 0.46 0.36 0.067 0.052 0.0025016
0.46 0.36 0.071 0.06 0.0030848 0.46 0.36 0.073 0.067 0.0025016
0.46 0.36 0.085 0.081 0.0030848 0.46 0.36 0.061 0.038 0.0033412
0.46 0.36 0.065 0.053 0.0036417 0.46 0.36 0.088 0.08 0.0033412
0.46 0.36 0.068 0.062 0.0036417 0.46 0.36 0.069 0.04 0.004188
0.46 0.36 0.085 0.08 0.0036417 0.46 0.36 0.078 0.063 0.004188
0.46 0.36 0.072 0.062 0.0042535 0.46 0.36 0.095 0.088 0.004188
0.46 0.36 0.089 0.08 0.0042535 0.46 0.36 0.074 0.045 0.005139
0.46 0.36 0.115 0.11 0.0042535 0.46 0.36 0.079 0.066 0.005139
0.46 0.36 0.1 0.094 0.005139
وليزادگان و اقدسی :اندازهگيری جريان در کانالها با استفاده از 1201 ... (علمی – پژوهشی)
ادامه جدول -3دادههای آزمايشگاهی در شرايط جريان مستغرق در شيبهای جانبی z=0.268و z=0.4663
z=0.4663 z=0.268
)B(m )d(m )y1(m )yt(m )Q(m3/s )B(m )d(m )y1(m )yt(m )Q(m3/s
0.46 0.42 0.039 0.03 0.000428 0.46 0.42 0.064 0.03 0.001393
0.46 0.42 0.041 0.036 0.000428 0.46 0.42 0.07 0.055 0.001393
0.46 0.42 0.05 0.035 0.001068 0.46 0.42 0.09 0.076 0.002285
0.46 0.42 0.055 0.048 0.001068 0.46 0.42 0.093 0.055 0.003256
0.46 0.42 0.06 0.055 0.001068 0.46 0.42 0.098 0.076 0.003256
0.46 0.42 0.062 0.048 0.001763 0.46 0.42 0.102 0.075 0.00402
0.46 0.42 0.07 0.063 0.001763 0.46 0.42 0.12 0.11 0.00402
0.46 0.42 0.087 0.081 0.001763 0.46 0.42 0.105 0.079 0.004235
0.46 0.42 0.078 0.066 0.003018 0.46 0.4 0.058 0.02 0.001658
0.46 0.42 0.08 0.072 0.003018 0.46 0.4 0.059 0.03 0.001658
0.46 0.42 0.085 0.08 0.003018 0.46 0.4 0.065 0.05 0.001658
0.46 0.42 0.087 0.081 0.003345 0.46 0.4 0.065 0.028 0.002024
0.46 0.42 0.09 0.085 0.003345 0.46 0.4 0.065 0.031 0.002024
0.46 0.42 0.095 0.091 0.003345 0.46 0.4 0.068 0.05 0.002024
0.46 0.42 0.092 0.082 0.00512 0.46 0.4 0.081 0.03 0.002981
0.46 0.42 0.096 0.09 0.00512 0.46 0.4 0.082 0.045 0.002981
0.46 0.42 0.097 0.092 0.00512 0.46 0.4 0.083 0.06 0.002981
0.46 0.4 0.047 0.03 0.001255 0.46 0.4 0.095 0.047 0.004532
0.46 0.4 0.05 0.04 0.001255 0.46 0.4 0.097 0.07 0.004532
0.46 0.4 0.057 0.052 0.001255 0.46 0.4 0.121 0.1 0.004532
0.46 0.4 0.052 0.035 0.001548 0.46 0.4 0.098 0.05 0.005009
0.46 0.4 0.055 0.047 0.001548 0.46 0.4 0.101 0.065 0.005009
0.46 0.4 0.065 0.06 0.001548 0.46 0.4 0.11 0.095 0.005009
0.46 0.4 0.061 0.045 0.001887 0.46 0.38 0.05 0.02 0.001733
0.46 0.4 0.065 0.057 0.001887 0.46 0.38 0.056 0.032 0.001989
0.46 0.4 0.075 0.07 0.001887 0.46 0.38 0.076 0.075 0.001989
0.46 0.4 0.069 0.055 0.002461 0.46 0.38 0.072 0.05 0.003137
0.46 0.4 0.072 0.062 0.002461 0.46 0.38 0.088 0.084 0.003137
0.46 0.4 0.091 0.083 0.002461 0.46 0.38 0.075 0.04 0.003436
0.46 0.4 0.085 0.07 0.003943 0.46 0.38 0.09 0.087 0.003436
0.46 0.4 0.087 0.079 0.003943 0.46 0.38 0.087 0.075 0.004488
0.46 0.4 0.105 0.098 0.003943 0.46 0.38 0.1 0.098 0.004488
0.46 0.4 0.09 0.078 0.005226 0.46 0.38 0.14 0.136 0.004488
0.46 0.4 0.091 0.081 0.005226 0.46 0.36 0.085 0.075 0.00247
0.46 0.4 0.108 0.1 0.005226 0.46 0.36 0.095 0.083 0.0039
0.46 0.38 0.044 0.016 0.00158 0.46 0.36 0.075 0.04 0.003878
0.46 0.38 0.044 0.018 0.00158 0.46 0.36 0.081 0.05 0.004737
0.46 0.38 0.045 0.025 0.00158 0.46 0.36 0.088 0.067 0.004737
0.46 0.38 0.054 0.022 0.002379 0.46 0.36 0.12 0.095 0.004737
0.46 0.38 0.055 0.03 0.002379 0.46 0.36 0.1 0.09 0.005053
0.46 0.38 0.056 0.045 0.002379
0.46 0.38 0.06 0.03 0.003031
0.46 0.38 0.06 0.035 0.003031
0.46 0.38 0.065 0.055 0.003031
0.46 0.38 0.066 0.035 0.003426
0.46 0.38 0.066 0.055 0.003426
0.46 0.38 0.075 0.065 0.003426
0.46 0.38 0.072 0.032 0.004305
0.46 0.38 0.072 0.04 0.004305
0.46 0.38 0.073 0.055 0.004305
0.46 0.38 0.08 0.028 0.005136
0.46 0.38 0.08 0.045 0.005136
0.46 0.38 0.082 0.07 0.005136
0.46 0.36 0.032 0.029 0.000557
0.46 0.36 0.045 0.02 0.001678
0.46 0.36 0.046 0.028 0.001678
0.46 0.36 0.055 0.05 0.001678
0.46 0.36 0.054 0.025 0.002655
0.46 0.36 0.055 0.03 0.002655
0.46 0.36 0.058 0.05 0.002655
0.46 0.36 0.061 0.032 0.003259
0.46 0.36 0.061 0.043 0.003259
0.46 0.36 0.065 0.06 0.003259
0.46 0.36 0.066 0.033 0.00408
0.46 0.36 0.068 0.05 0.00408
0.46 0.36 0.071 0.065 0.00408
0.46 0.36 0.075 0.045 0.004804
0.46 0.36 0.078 0.06 0.004804
0.46 0.36 0.095 0.088 0.004804
1202تحقيقات آب و خاک ايران ،دوره ،52شماره ،5مرداد ( 1400علمی – پژوهشی)
y
1
ب الف
شکل -2الف :کانال آزمايشگاهی حين انجام آزمايش در شرايط جريان آزاد ب :شکل شماتيک مقطع عرضی کانال و پايه استوانهای )(Badar and Ghare 2012
0.11 0.18
=y 0.573x1.9353 0.16 y = 0.488x1.7302
R² = 0.9657
Q/(gBc5)0.5
Q/(gBc5)0.5
0.4
Q/(gBc5)0.5
0.2
0.3
0.2
)◦z=0.268 (a=75 0.1
0.1 )◦z=0.4663 (a=65
0
0.2 0.4 0.6 0.8 1 1.2 0
0.2 0.3 0.4 0.5 0.6 0.7 0.8
y1/Bc y1/Bc
شکل -3تغييرات y1/Bcدر برابر Q/(gBc5)0.5در شيبهای جانبی مختلف در شرايط جريان آزاد
جریان بیبعد ) (Q/(gBc5)0.5برای شیبهای جانبی مختلف در تغییرات پارامتر بیبعد عمق جریان ) (y1/Bcدر برابر دبی
وليزادگان و اقدسی :اندازهگيری جريان در کانالها با استفاده از 1203 ... (علمی – پژوهشی)
y = 0.4563x1.675
0.4 R² = 0.972
Q/(gBc5)0.5
0.2
تمام شيب های جانبی بررسی شده
0
0.2 0.4 0.6 0.8 1 1.2
y1/Bc
شکل -4تغييرات y1/Bcدر برابر Q/(gBc5)0.5در شرايط جريان آزاد برای تمام شيبهای جانبی بررسی شده
جریان آزاد بدست آمده دارای دقت مناسبی است مقدار پارامتر آماری MAREو RMSEبر اساس شکل (،)4
جريان مستغرق
به ترتیب 8/2درصد و 0/017بدست آمده است.
در این شرایط بر اساس رابطه ( ،)10پس از انجام حداقل 192 با توجه به منحنی شکل ( ،)4رابطه بین محاسبه دبی جریان
آزمایش در چهار شیب جانبی مختلف (حداقل 48آزمایش در هر در شرایط جریان آزاد به صورت رابطه ( )14است.
شیب جانبی) ،تغییرات پارامتر بدون بعد Q/(gyt5)0.5در برابر
Q 0.4563 g 0.5 Bc0.825 y11.675 (رابطه )14
) (Bcy1/yt2برای هر چهار شیب جانبی بررسی شده در شکل ()5
بنابراین رابطه ( )14که برای محاسبه دبی جریان در شرایط
نشان داده شده است.
16 10
y = 0.0133x2 + 0.4013x - 0.1916 y = 0.0221x2 + 0.3037x - 0.709
R² = 0.9652 8 R² = 0.9372
12
Q/(gyt5)0.5
Q/(gyt5)0.5
6
8
4
4 2
z=0.7 z=1
0 0
0 2 4 6 8 10 12 14 16 18 20 22 0 3 6 9 12 15
)(Bc/yt)(y1/yt )(Bc/yt)(y1/yt
12 20
10 =y 0.0119x2 + 0.5928x - 0.4226 y = 0.0083x2 + 0.6123x - 0.6317
R² = 0.9946 R² = 0.9823
15
8
Q/(gyt5)0.5
Q/(gyt5)0.5
6 10
4
5 z=0.4663
2 z=0.268
0 0
0 5 10 15 0 5 10 15 20 25
)(Bc/yt)(y1/yt )(Bc/yt)(y1/yt
شکل -5تغييرات Q/(gyt5)0.5در برابر ) (Bc/yt)(y1/ytدر شيبهای جانبی مختلف در شرايط جريان مستغرق
1204تحقيقات آب و خاک ايران ،دوره ،52شماره ،5مرداد ( 1400علمی – پژوهشی)
ترتیب 0/27 ،0/32 ،0/34و 0/16میباشد .بنابراین دقت برآورد در منحنیهای شکل ( ،)5مالحظه میگردد با کاهش
دبی جریان در شرایط جریان مستغرق با استفاده از منحنیهای نسبت استغراق ) (yt/y1و یا با افزایش نسبت ،y1/ytدبی بیبعد
شکل ( )5نسبت به جریان آزاد پایین است. Q/(gyt5)0.5افزایش مییابد.
از همپوشانی نمودارهای شکل ( ،)5منحنی تغییرات مقدار پارامتر آماری MAREبر اساس منحنیهای شکل
Q/(gyt5)0.5در برابر ) (Bc/yt)(y1/ytبرای تمامی شیبهای جانبی ( )5برای شیبهای جانبی ) 0/4663 ،0/7 ،1 (zو 0/268به
بررسی شده بدست میآید (شکل .)6 ترتیب 19 ،22/9 ،25/17و 14/9درصد برآورد شده است.
همچنین پارامتر آماری RMSEبرای شیبهای جانبی مذکور به
20
y = 0.0193x2 + 0.3596x - 0.2251
15 R² = 0.9224
Q/(gyt5)0.5
10
5
تمام شيب های جانبی بررسی شده
0
0 5 10 15 20 25
)(Bc/yt)(y1/yt
شکل -6تغييرات Q/(gyt5)0.5در برابر ) (Bc/yt)(y1/ytدر تمامی شيبهای جانبی بررسی شده در شرايط جريان مستغرق
در شرایط جریان مستغرق مناسب به نظر نمیرسد. علیرغم مناسب بودن ضریب رگرسیونی رابطه بین
درQ/(gyt5)0.5بر اساس رابطه ( )11تغییرات yt/y1در برابر ) (Bc/yt)(y1/ytدر برابر Q/(gyt5)0.5در شکل ( )6که برابر 0/92
شکل ( ) 7ارائه شده است .از روی نمودارهای این شکل دیده بدست آمده ،محاسبه دبی جریان بیبعد با استفاده از این شکل
میشود که با افزایش نسبت استغراق ) (yt/y1دبی بیبعد دارای MAREو RMSEبه ترتیب برابر با 35/9درصد و 0/48
Q/(gyt5)0.5کاهش مییابد. میباشد .بنابراین استفاده از این شکل برای محاسبه دبی جریان
25 10
20 y = 0.579x-3.83 8 y = 0.4699x-3.712
R² = 0.927 R² = 0.8734
Q/(gyt5)0.5
Q/(gyt5)0.5
15 6
10 4
z=0.7 z=1
5 2
0 0
0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.4 0.5 0.6 0.7 0.8 0.9 1
yt/y1 yt/y1
20 15
R² = 0.921
10 R² = 0.9165
5 z=0.268
5 z=0.4663
0 0
0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
yt/y1 yt/y1
شکل -7تغييرات yt/y1در برابر Q/(gyt5)0.5در شيبهای جانبی مختلف
وليزادگان و اقدسی :اندازهگيری جريان در کانالها با استفاده از 1205 ... (علمی – پژوهشی)
ارائه شوند ،تغییرات yt/y1در برابر Q/(gyt5)0.5برای تمام مقدار MAREدر تعیین دبی جریان با استفاده از
شیبهای جانبی بررسی شده حاصل میشود .شکل ( )8این منحنیهای شکل ( )7برای شیبهای جانبی )0/4663 ،0/7 ،1 (z
تغییرات را نشان میدهد .ضریب رگرسیونی رابطه بین نسبت و 0/268به ترتیب برابر با 22/7 ،20/2 ،21/3و 23/8درصد و
استغراق ) (yt/y1و Q/(gyt5)0.5در شکل ( )8معادل 0/8484 مقدار RMSEبرای شیبهای جانبی مذکور به ترتیب برابر با
بدست آمده و مقادیر پارامترهای MAREو RMSEدر محاسبه 0/38 ،0/38 ،0/37و 0/28میباشد که نشان دهنده دقت نسبتا
دبی جریان بیبعد با استفاده از منحنی ارائه شده در این شکل پایین این منحنیها در مقایسه با شرایط جریان آزاد (رابطه )14
برابر 34/3درصد و 0/39است. است .چنانچه دادههای نمودارهای شکل ( )7در قالب یک نمودار
20
y = 0.5179x-3.368
15 R² = 0.8484
Q/(gyt5)0.5
10
0
0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
yt/y1
شکل -8تغييرات yt/y1در برابر Q/(gyt5)0.5در تمامی شيبهای جانبی بررسی شده در شرايط جريان مستغرق
رابطهای واحد برای محاسبه دبی جریان در شرایط جریان بنابراین استفاده از شکلهای مذکور برای محاسبه دبی
مستغرق در محدوده شیبهای جانبی بررسی شده انجام شده جریان ،دقت مورد انتظار را ندارد .دلیل باال بودن مقدار MARE
است. و RMSEدر این دو شکل( شکلهای 6و )8همپوشانی دادههای
دبیهای بیبعد اندازهگیری شده و محاسبه شده در شرایط مربوط به شیبهای جانبی بررسی شده در قالب یک نمودار
جریان آزاد بر اساس شکل (( )4رابطه )14در محدوده میباشد (نمودارهای شکل 5در قالب نمودار شکل 6و نمودارهای
خطای ±10درصد مقایسه و در شکل ( )9ارائه شده است. شکل 7در قالب نمودار شکل )8که با هدف بدست آوردن
0.6
0.5
Q/(gBc5)0.5 cal.
0.4
0.3
0.2
0.1
0
0 0.1 0.2 0.3 0.4 0.5
5 0.5
Q/(gBc ) exp.
شکل -9مقايسه دبیهای بیبعد اندارهگيری شده و محاسبه شده درشرايط جريان آزاد در تمام شيبهای جانبی بررسی شده در محدوده خطای ±10درصد بر
اساس رابطه ()14
توان و ضریب عمق جریان بدون بعد در رابطه ارائه شده با توجه به شکل ( )9مشخص میشود اکثر دبیهای بیبعد
توسط ) Samani and Magallanez (1993که هم برای شرایط محاسبه شده در محدوده خطای ±10درصد دبیهای بیبعد
جریان آزاد و هم برای شرایط جریان مستغرق (که بدون در نظر آزمایشگاهی قرار دارند.
1206تحقيقات آب و خاک ايران ،دوره ،52شماره ،5مرداد ( 1400علمی – پژوهشی)
Mohammadi and ) %3 ،Bonacci (1997و در تحقیقات گرفته شدن نسبت استغراق ارائه شده) ،به ترتیب 1/51و 0/226
) ،Vatankhah (2020در رابطه اول (استفاده از پایههای میباشد .اما در رابطه بدست آمده در تحقیق حاضر (رابطه )14
استوانهای) %2/72 ،و در رابطه دوم (استفاده از پایههای به ترتیب 1/675و 0/4563بدست آمده است .مشخص است که
مخروطی) %1/85 ،گزارش شده است .در تحقیق حاضر مقدار خطا مقادیر توان و ضریب بدست آمده در این تحقیق بیشتر از تحقیق
در محاسبه دبی جریان با استفاده از رابطه بدست آمده در شرایط ) Samani and Magallanez (1993است .این موضوع به این دلیل
جریان آزاد در کانال ذوزنقهای با شیب جانبی )،0/7 ،1 (z می تواند باشد که به ازای یک دبی جریان معین ،عمق جریان در
0/4663و 0/268به ترتیب برابر با با 8/1 ،4/6 ،6/2و %9/4و باالدست گلوگاه در شرایط جریان مستغرق بیشتر از شرایط جریان
در شرایط جریان مستغرق برای شیبهای جانبی مذکور به ترتیب آزاد خواهد بود (به دلیل تاثیر عمق پایاب روی عمق باالدست) .با
19 ،22/9 ،25/17و %14/9در روش اول (منحنیهای شکل،)5 توجه به اینکه در تحقیقات این محققین جهت بدست آوردن
و در روش دوم (منحنیهای شکل 22/7 ،20/2 ،21/3 )7و رابطه محاسبه دبی جریان ،از دادههای شرایط جریان مستغرق نیز
%23/8بدست آمده است. استفاده شده لذا در تحقیقات مذکور جهت بدست آوردن رابطه
محاسبه دبی جریان ،به ازای یک دبی جریان معین از مقادیر
نتيجهگيری بزرگتری برای عمق جریان باالدست (نسبت به شرایط جریان
جهت انجام این پژوهش ،کانال آزمایشگاهی با شیب جانبی قابل آزاد) استفاده شده است .به عبارت دیگر در شرایط مساوی از نظر
تنظیم و پایههای استوانهای(به تعداد چهار عدد در ابعاد مختلف) دبی جریان ،مقدار عمق جریان استفاده شده در رابطه محققین
در آزمایشگاه هیدرولیک ساخته شد .آزمایشات متعددی در مذکور بیشتر از عمق جریان استفاده شده در رابطه بدست آمده
شرایط جریان آزاد و مستغرق بر اساس روابط تابعی و بدون بعد در تحقیق حاضر باید باشد.
بدست آمده از آنالیز ابعادی صورت گرفتند و نتیجهگیری شد که در رابطه ارائه شده توسط ) Ghare and Badar (2012که بر
استفاده از این سازه در شرایط جریان آزاد قابل اطمینان بوده و اساس دادههای آزمایشگاهی دیگر محققان از جمله Samani and
رابطه بدست آمده جهت محاسبه دبی جریان بیبعد در هر شیب ) Magallanez (1993برای شیب جانبی z=1بدست آمده ،از
جانبی به طور جداگانه و رابطه ( )14که برای تمام شیبهای گروههای بدون بعدی که با گروههای بدون بعد بکار رفته در تحقیقات
جانبی بررسی شده بدست آمده از دقت مناسبی برخوردار است ) Samani and Magallanez (1993و تحقیق حاضر تفاوت دارد
به طوریکه میانگین قدر مطلق خطای نسبی ) (MAREو خطای استفاده شده است .همچنین در این رابطه نیز تاثیر نسبت استغراق
جذر میانگین مربعات ) (RMSEدر محاسبه دبی جریان با نادیده گرفته شده است .توان و ضریب عمق جریان بدون بعد در
استفاده از این رابطه به ترتیب برابر 8/2درصد و 0/017میباشد. رابطه ) Ghare and Badar (2012به ترتیب 2/438و 0/446
ساخت کانالهای ذوزنقهای با شیب وجه جانبی 1:1خیلی رایجتر میباشد .رابطه بدست آمده در تحقیق حاضر (رابطه ،)14یک رابطه
است ،لذا با توجه به اینکه مقادیر MAREو RMSEمربوط به با درجه 2/5نسبت به عمق جریان در باالدست گلوگاه میباشد که
این شیب جانبی که به ترتیب 6/2درصد و 0/006میباشد، باالتر از توان بار هیدرولیکی روی تاج سرریز در رابطۀ سرریزهای
استفاده از منحنی و رابطه ارائه شده در شکل ( )3مربوط به شیب مستطیلی لبه تیز (که 1/5میباشد) ،و مساوی توان بار هیدرولیکی
جانبی z=1دارای دقت باالتری نسبت به رابطه ( )14میباشد .در روی راس سرریز در رابطۀ سرریزهای مثلثی لبه تیز است .این موضوع
هر شیب جانبی دقت برآورد دبی در شرایط جربان مستغرق پایین نشان دهنده حساسیت باالی این سازه در محاسبه دبی جریان در
بوده و استفاده از این سازه در این شرایط بر اساس نتایج حاصل شرایط جریان آزاد نسبت به تغییرات عمق جریان در باالدست گلوگاه
از تحقیق حاضر پیشنهاد نمیگردد .استفاده از یک رابطۀ واحد است.
برای محاسبه دبی جریان که هم در شرایط جریان آزاد و هم در مقدار خطا در محاسبه دبی جریان با استفاده از رابطه
شرایط جریان مستغرق بکار رود مناسب نیست و باید رابطه مربوط بدست آمده در تحقیقات ) ،%5 ،Hager (1985در تحقیقات
به هریک از شرایط جریان آزاد و مستغرق بطورجداگانه استفاده ) ،%8/7 ،Mattar (2017در تحقیقات ) ،%5 ،Das et al. (2017در
شود .حساسیت این سازه نسبت به تغییرات عمق جریان در تحقیقات ) ،%9 ،Kapoor et al. (2019در تحقیقات Ghare and
باالدست گلوگاه ،همسطح سرریزهای مثلثی لبهتیز و باالتر از ) ،%4/7 ،Badar (2012در تحقیقات Samani and Magallanez
سرریزهای مستطیلی لبهتیز است .بهتر است از نتایج بدست آمده ) ،%5/1 ،(1993در تحقیقات ) Ghare and Badar (2014در رابطه
در محدوده متغیرهای موثر در این تحقیق استفاده شود. اول 5و در رابطه دوم ،%20در تحقیقات Peruginelli and
1207 ... اندازهگيری جريان در کانالها با استفاده از:وليزادگان و اقدسی )(علمی – پژوهشی