YOFC_10018_WP

Optical Cable Anti-rodent Performance


Ruan Yunfang, Lu Xingxing
July 2010

1. Introduction Optical Cable Damaged by Rats


Along with the further development of Along overhead communication cable line,
optical fibre communication, the use of optical areas subject to severe damage caused by rats
cable becomes more and more popular; but have a common feature: the vegetation is fairly
different service environments have different developed, the natural conditions are good and
cable protection requirements. In some areas very suitable for the survival of murine,
subject to severe damage caused by rats, optical especially for squirrels. Such rodent with
cables often get bitten off by murine, resulting tenacious vitality and fecundity has the habit of
great difficulty in line maintenance. biting something to keep its tooth sharp, because
Considering factors like ecological its incisors are extremely developed and
environment protection and feasibility, anti- continuously growing. The overhead optical
rodent measures like poisoning and trapping cable running through woods not only provides
cannot be used for optical cable lines; therefore, entertainment platform for murine, but also
optical cables with anti-rodent function have attracts them by the special hardness and
become the choice of telecommunication fragrance of the cable sheath; the cable
operators. As the equipment of communication therefore becomes the teeth-grinding target of
cable manufacturers are not unified, and the murine.
degrees of cognition on optical anti-rodent
study are different, and besides there is no
3. Study on Optical Cable Anti-
national standard for anti-rodent cables, the rodent Performance
enterprises therefore have made many anti- 3.1 Concept of Optical Cable Anti-rodent
rodent cables of various structures according to
Anti-rodent is to adopt various
the features of their own equipment. This
organization forms to control the damage of
article briefly analyzes why rats bite cables,
optical cables caused by rats within the
introduces the current situation of domestic and
specified extent. The basic condition of anti-
international cable anti-rodent technologies,
rodent performance is that the cable core
analyzes anti-rodent principles of different
cannot be damaged.
cable structures, compares anti-rodent effects
of different cable structures by rat bite tests, 3.2 Optical Cable Anti-rodent Approach
and solves the problem of optical cable damage Anti-rodent methods for optical cable
caused by rates in view of the optical cable mainly comprise chemical anti-rodent and
structure design and the material selection. physical anti-rodent methods.
2. Brief Analysis for Cause of Chemical anti-rodent methods: chemical

YOFC reserves the right to the final interpretation of the above terms
anti-rodent method is to add rat repellents in possibility of proper introduction when
outer sheath of optical cable by certain conditions mature is reserved in the wording of
proportion for the purpose of rat prevention; the standard.
commonly used rat repellents comprise Physical anti-rodent methods. In general,
synthetic lindane and synthetic capsaicine. physical anti-rodent method is guaranteed by
Physical anti-rodent methods: there are the structure and material of optical cable; and
two physical anti-rodent methods; one is to the anti-rodent performance can usually be
utilize the hardness of optical cable material to validated by tests and inspections. Therefore,
resist the rat bite, for examples, install rigid before comparing the anti-rodent performance
metal tape armor or fine round steel wire or of each structure, have a look at the laboratory
FRP rod and the like in optical cable; the other comparison test on rat bite control of each
is to utilize the sharpness of anti-rodent cable structure.
material to sting the rats, such that the rat teeth 3.4 Laboratory Anti-rodent Performance
can hardly penetrate the cable or rats may feel Comparison Test
uncomfortable after their mouth is stung by
glass fibre, and the cable core is therefore By far, there is no national or industrial
protected; commonly used devices include standard for test method of anti-rodent cables;
glass fibre yarn and glass fibre tape. and the validation is generally carried out with
reference to the 7-day anti-rodent test invented
3.3 Performance Comparison of Various Cable by the U.S. fish and wildlife service
Anti-rodent Methods organizations. The test standard is to compare
Chemical anti-rodent methods. Tests on and evaluate the damage degree of samples of
laboratory rat indicate that capsaicine can act test after the test; it should be noted that the
strong stimulation to the mouth mucosa and damage degree of sample means the damage
gustatory nerves of rats and make them give up degree of the rat barrier layer. Among the given
chewing, so as to effectively prevent damage set of 10 samples, if the damage index is 2 or
caused by rats. In view of economic efficiency less than 2, it should be deemed as pass. Such
and easy operation, adding certain proportion test is only a conformity test. The damage
of rat repellent (capsaicine) in cable sheath index of optical cable is given in Table 1.
should be the best choice, if the long-lasting Table 1 Damage Index of Optical Cables in anti-
anti-rodent effect could be achieved. But in Rodent Test
view of environmental protection and
durability, the following problems must be Index Definition
solved for using capsaicine: first, the 0 No damage
volatilization of capsaicine during production; l Single partial penetration in outer sheath
a large quantity of spicy gas volatilizes when 2 Multiple penetrations in outer sheath
extruding the mixture of capsaicine and sheath 3 Penetration in armor layer
material by extruding machine; such gas 4 Optical fibre damaged
spreads quickly in workshop and hurts the
respiratory tract and eyes of operators, which is According to this standard, we have made
against the people oriented idea of current the anti-rodent performance comparison test at
enterprises; second, capsaicine is gradually lost Laboratory Animal School of Medicine of
from sheath material after a long period in Tongji Medical College of Huazhong
outdoor environment; therefore the anti-rodent University of Science and Technology; fifty
effect and effective time of such cable can hardly 250-300g SD male rats were selected and
be guaranteed. Therefore, on the discussion for randomly raised in 10 cages, with 5 in each
establishment of national standard of anti- cage; 10 pieces of 30cm optical cable samples
rodent cables, all participating experts with sheath A (GYTA), steel belt sheath
expressed that the chemical anti-rodent method (GYTS), FRP band and fibreglass yarn sheath
should not be encouraged, in principle; and the were put into the 10cages respectively; the
YOFC reserves the right to the final interpretation of the above terms
samples were fixed by steel wire; and the rats checked.
were provided with sufficient food and water. The following table describes results.
During the experiment, SD rats were free of
any poisoning/death, and their diet was normal;
after 14days, the damage of each sample was
Table 2
Type of optical Damage Quantity of
Definition Sample number
cable index sample
0 No damage
Partial penetration in
1
outer sheath
Multiple penetrations in
Sheath A 2
outer sheath
3 Penetration in armor layer 1#, 7#, 2
2#, 3#, 4#, 5#, 6#,
4 Optical fibre damaged 8
8#, 9#, 10#
0 No damage
Partial penetration in
1 3#, 5#, 2
outer sheath
Steel belt sheath Multiple penetrations in 1#, 2#, 4#, 5#, 7#,
2 8
outer sheath 8#, 9#, 10#
3 Penetration in armor layer
4 Optical fibre damaged
0 No damage
Partial penetration in
1 1#, 5#, 2
FRP tape or outer sheath
fibreglass yarn Multiple penetrations in 2#, 3#, 4#, 6#, 7#.
2 8
sheath outer sheath 8#, 9#, 10#
3 Penetration in armor layer
4 Optical fibre damaged

Cable samples of various structures are as shown in Figure 1.

Sheath A optical cable

YOFC reserves the right to the final interpretation of the above terms
Steel belt sheath cable

Fibreglass yarn or belt cable

Figure 1 Cable Samples of Different Structures

Based on comparison of these damaged materials, which is not economically efficient;


samples, it can be seen that sheath A cable has second, the repeated anti-rodent ability is poor,
no anti-rodent ability at all; steel belt sheath because only for the reason of difficult to bite,
and FRP belt sheath both have anti-rodent rats will not stop attacking the cables, and the
abilities. line will be damaged sooner or later. Third,
Steel belt sheath has utilized the hardness such cables are heavy, leading great loads to
of the steel belt. Based on this principle, poles and towers; and the cables are fairly rigid,
manufacturers have developed the GYTS resulting in inconvenient laying and
structure of general anti-rodent function, the maintenance. Fourth, metals are good electric
GYTS53 and GYTA53 and GYTY53 cables conductors; after the cable is damaged, exposed
with better anti-rodent performance; and some metal may cause significant danger to the line.
even use fine round steel wire as the armor of Fibreglass anti-rodent method uses the
cable. In view of structure, all these cables have principle that the rat gives up biting after its
anti-rodent ability, but they also have mouth being stung by the fibreglass. Fibreglass
disadvantages. First, conventional chrome anti-rodent method is often reported and used
plated steel belt or phosphate steel wires rust abroad. Fibreglass is very small and fragile,
very soon and lose the protection ability after when rats bite the optical cable, the fine glass
being bitten by rats and exposed in air; but if fibre will sting the mouth of rats, make them
stainless steel wires are used, the material cost extremely unconformable; meanwhile, the
will be much more expensive than conventional specific memory and information exchange
YOFC reserves the right to the final interpretation of the above terms
among biotic population makes the rats fear the are all non-metal materials, thus no adverse
optical cables in some extent, so as to realize the effect will be caused to the optical cable
anti-rodent effect. This anti-rodent structure has maintenance after the outer sheath is penetrated
two forms; one is to use fibreglass yarn, i.e., by rats; therefore, these are much better choices.
many fibreglass yarns are wrapped clockwise
and counterclockwise on the inner sheath 4. Conclusion
surface to a certain thickness prior to extruding In general, chemical method is economical,
the outer sheath. This form has high equipment but not recommended, because of the
requirement, and needs many awls to arrange environmental protection and durability
the fibreglass yarns. The other is to use problems. In terms of physical anti-rodent
fibreglass belt; i.e., the extremely fine method, all optical cables having rigid metal
fibreglass yarns are bonded into belt of uniform structure have certain anti-rodent ability, with
thickness and suitable width; and modified only different in repeatability and durability of
capsaicine (microencapsulated capsaicine anti-rodent effect, and with certain hidden
wrapped by organic matters) is mixed into the dangers in line maintenance; when using
belt when curing the belt. During production of fibreglass yarn, it must be wrapped on the cable
optical cable, the fibreglass belt is wrapped core by certain thickness to achieve good anti-
outside the inner sheath, and then the outer rodent effect, and certain amount of yarn
sheath is extruded thereof. The capsaicine is equipment is required, the anti-rodent method
between the inner and the outer sheaths, even may not be very economical, but the resultant
the microcapsule breaks under high optical cable is of flexibility and bending
temperature, there is no irritant gas leaking performance; using fibreglass in anti-rodent
during production; and in long-term use, the method of optical cable has relatively simple
capsaicine migrates into the outer sheath, requirement on paying off equipment, and the
which enables better anti-rodent effect in optical cable shaping is more easier, the cost is
association with the fibreglass. The two anti- relatively economical.
rodent forms can effectively improve the
problem of continuous rat attack on optical
fibre; meanwhile, the used protective materials