VeLINO FT 822 - 823 - 824 FT 922- 923-924 e-escalator Operating manual 6 Operation using the control panel 6.1 General ‘The control panel comprises: + atwosine display field and = akeypad with 4 Keys. The keys are assigned digits and functions (s0e ilustraton). Display field (1)Up (8) Serol ems Infra-red interface 2) Down (4) Enter ‘The keypad on the contol panel is protected against unauthorised use by a password. This password is set on delivery to: 1 2.3.4.3 For security, the password can be New password changed by the user (see chapter 6.7.5) and should be writen in the space alongside. itn operator commands ate entered over a period of § minutes, the control panel reverts to report level (current status report or fault report will be displayed). Aer a further 5 minutes, the control panel wil blank out, This does not cause any information to be lost Pressing any key will bring back the latest display. When @ new report is generated, the control panel becomes lve again automaticaly. / 20 Man 02-260-08-E ‘xem E50 6.2 (3) 6.3 Enter password erste LE te, The text OPassword?™ will be displayed Enter the 5-cigt password (see chapter 6.1). ‘The figures are obtained by use of the keys as inthe diagram alongside In the upper line the frst main menu ‘Oconto wil appear In the lower ine the curtent time and date will appear. Summary of main menus The following main menus can be called up on the control pane! ~ Control - Statistics Veut NO FT 822 - 823 - 824 FT 922-923-924 e-escalator Operating manual @ Control 14:40:45 15.01.01 = Diagnostic ig (only for maintenance staff, protected by service password). ~ Language selection ~ Configuration Each main menu contains a set of sub-menus. The following diagrams illustrate how the menu levels are constructed, and how you ‘can move around within them to program the escalator (see also chapter 6.4 to chapter 6.7). Man 02-260-08-E a1 an VeLINO FT 822-923 - 824 FT 922 - 923 - 924 eescalator Operating manual QO “ThyssenKrupp Escalators Pe ee ee ‘Subsmenu see chapter 6.4 Control 14:40:45 15.01.01 Statistics 0:45 15.01.01 ‘see chapter 6.5 La Li [}+—~| Ley amet ‘Sub-menu K LY rarer ‘Sub-menu Language sclection 14:40:45 15.01.01 : see chapter 6.6 ; a lay = } (~ Configuration at ‘Sub-menu t 14:40:45 15.01.01 ‘see chapter 6.7 i Ley L -- Main menu level --- 2 Man 02-260-09-E ones FT 822-828-804 FT 922-923-924 e-escalaior : oO Operating marwal ‘@) 6.4 Control Control t Control a 14:40:45 15.01.01 2 Operation stop Teleservice OFF Energy Control OFF ae + Main menu level ~ Man 02-260-08-E 23 ‘S VeLINO F782 - 823 - 824 FT 922 - 923 - 924 e-escalator oO Operating manual OQ 6.5 Statistics Statistics y, Statistics 5 digit ‘View memory number ~ 0.99999 5 digit auraber = 0.99999 5 digit sumnber = 0.99999 Statistics Oo 3 digit lability : 100% ) number = 010% 4 digit number = 0.9999 24 Man 02-260-09-€ tte oe Pee VeLINO FT 822 - 823 - 824 FT 922 - 923 - 924 e-escalator oO Operating manual 6.6 — Language selection Language selection ~) + Language selection 14:40:45 15.01.01 2 | Deutsei Language selection Frangais Language selection Traliano further languages Man 02-260-08-€ 25 ee te ao Pe ee VeLINO FT 822 - 823 - 824 FT 822 - 923 - 924 e-escalaior (a. Operating manual 8.7 Configuration Configuration Set time, date 1 15.01.01 see chapter 6.7.1 Ley r 4 | Interface configuration | i a {only with sonics password) = (Only active if the function Enter times interm. intermittent’ is set to CON" By soe chapter 6.7.2 inthe OControl" menu. oe Enter times TEC i see chapter 6.7.3, ; + Only active ifthe function Settimer 1 | Timer is set to CON" in 7 800 chapter 6.7.4 | the CConttot” menu a ‘Only active i the function Settimer 2 Timer isso to GON" in > see chapter 6.7.4 | the OContro!" menu. Ley gq ! ba i ‘Change password i see chapter 6.75 : Ley 7 2% Man 02-260-08-E Sno UO FT 922 - 923 -924 e-escalator ‘Operating manual 6.7.1 Settime, date Selec! OContiguration’ from the main meng, then select the sub-function CSet time, date" {see chapter 6.7). The text OSet time, date" end the ‘current time and date settings will be displayed. 14:40:45 15.01.01 The second digit of the hours display wil lash, tree] key to setit to (0-28) press tte key. Set time, date: WED 14:40:45 15.01.01 The first digit of the minutes display wil flash Use tneAbey to setit to (0-5). Press the ty Set time, date: WED 14:40:45 15.01.01 ‘The second digit ofthe minutes display wil flash, Use the Calhay setts (9). press the 7 key Set time, date: WED 14:40:45 15.01.01 ‘The first digit of the seconds display will lash, use tne (al key 0 sat it to (0-5) Man 02-260-08-E 2 “host en VeLINO F1-822 - 823 - 824 FT 922 - 923 - 924 e-escalator Operating manual pes to ty esting ie: WED 14:40:43 15.01.01 ‘The second digit of the seconds display wil flash, usette hey setito 09), 7 Set time, date: WED Press the "key. 14:40:45 15.01.01 The first digi flash. of the date display wil Use the + Jkey to set the frst digit of the date to (0-3). YP Setting aot WED Bement 14:40:45 15.01.01 ‘The second digit ofthe date splay will fash, ure teal Key to set the second digit oO of the date to (0-9). Inthe same way, set the month and the year. Alter this, the display reverts tothe day of the week. Use te ley ste the cores day See ofthe week (MON-SUN). z 01. press trol key. ‘That completes the setting procedure. IF you need only change @ few settings, you can ext the satup procedure at any point by pressing the [ay key. 28 Man 02-260-03-E ‘hk ek 672 VELINO FT 822 - 823 - 824 FT 922 - 928 -924 e-escalator Operating manual Setting times for intermittent operation Note: Intermittent operation is available only i the escalator is fitted with signal lights and either contact mats or light barier, Note: To activate intermittent operation, goto the OControl" menu and set the DDintermittet” function to GON" (see chapter 6.4). For intermittent operation, the following times must be entered (see also chapter 4.5): 'D+* (positive time): Running time for the escalator (permitted range: 010 s to 999s). ‘Note: For safety, the running time must be min. 10 s longer than the bare transittime of auser between activating the entry switch {contact mat o ight barrier) and reaching the end of the escalator! + D+ (negative ime): Blocking time (Demonstration time) for persons that have attempted to use the escalator in the wrong direction (permitted range: 10 s to 99 s). ‘Note: The blocking time cannot be less than 10 st To set the times: Select OConfiguation” from the main menu, then select the sub-funeion Enter times inter.” (see chapter 6.7) ‘The text DEnter times inter.” and the current settings forthe times willbe displayed. ress the Enter times interm. presse ey ot nes int The first digit ofthe C+" ie wil flash, mrss te lor They xetody unt the desived figure is cisplayed Enter times interm. oat #10608 -: 10s The second digit wll fash. ors ne Calor Tia opentedy until the desired second figure is displayed Man 02-260-03-€ 29 sae en VeLIno FT 822 - 828 - 824 FT 922 - 923 - 924 e-escalator Operating manual oO 673 30 In the same way, set the third figure ofthe 0+" time also. Then the display reverts tothe O-" time, The frst digit of the O-" time wil fash, F Enter times interm. #:060s -: 105 mess tao “Tey petedy Until the desired figure is displayed. press he ty Inthe same way, set te second figure ofthe O- time also, That completes the setting procedure, Setting times for ThyssenKrupp Energy Control (TEC) Note: To activate Thyssenkrupp Energy Contto, go to the (Conirol” menu and set the Energy Control function to CION" (see chapter 6.4). For operation with Energy Control, the folowing times must be set: = D4" (postive time): Running time ofthe escalator at ull speed (setting range: 000 s to 999 s). O To set the time: ‘Select (Configuration* from the main menu, then select the sub-functc time” (see chapter 6.7). ‘The text Center times TEC" and the current settings for the times willbe displayed. Press the key. ‘The frst digit of the C+" time will flash. Enter TEC Press the G ‘or Qj key repeatedly until the desired figure is displayed. Press the ey key. In the same way, set the second and third figures of the O" time also, ‘That completes the setting procedure. ‘Man 02-260-08-E paarasy Setting timers 7 and 2 Vetino FT 822 - 828 - 824 FT 922 - 923 - 924 e-escalator Operating manual Note: To activate the timers, go to the OControf' menu and set the OTimers" function 10 00N" Note: The setting procedure is the same for beth timers. Using the two timers in combination, with different setings formes and days ofthe week, a wide variety of ime settings can be achioved. Select UConiiguration" from the main menu, then select the sub-tunction Set timer 1” (see chapter 6.7) ‘The text OSet timer 1" and the current time and date settings will be displayed. Press te bey ‘The hours display Con" wil fash. vsettealoyio ease he switching on time, or the Q] key to reduce i, untl the desired hours are displayed. pastel ey, ‘The minutes display Con’ will fash, use te Calkeyioinsease te vison be, or tte hay reduce i, until the desired minutes are displayed, Set the switching off times Goffin the same way. Man 02-260-09-E erence Set timer 1: Daily on: 08:00 off: 18:00 Set timer 1: Daily on: 08:00 off: 18:00 31 VEeLINO 1822-825 -e24 FT 922 - 923-924 e-escalator (ay Operating manual ‘Then the lay will Then the day dspay wil flesh, Set timer 1: Daily bn: 08:00 of 18:00 Use ee cy to set the costed day: ~ Daily: Daily, + MON /.../ SUN: individual days of the week, Monday thru Sunday, ~ MON-ERI: combination Monday to Friday, ~ SAT-SUN: combination Saturday to Sunday, + OFF: Timer 1 not used. ress to ty ‘The setting of mer 1 is complete. To set timer 2: — The settings for ier 2 willbe “ “ cisplayed. Set timer 2 in the same way as described a) for timer 1 7 32 Man 02-260-08-E re 67.5 VeLIno FT 822 - 829 - 824 FT 922 - 923 - 924 e-escalator Operating manual Change password ‘Select GConfiguration* irom the main ‘menu, then select the sub-function GChange password" (see chapter 6.7). ‘Tho text GChange password" and the ‘ld password wil be displayed. nea va ane cei ret ogtetOe e psw W flash. Note: The figures 1, 2, 8 and 4 can be Used in any order to from a password, however the figure 4 may not be used as the first digit. Enter the new password inthe folowing way: Press the Grey Luni the desired figure 's displayed. old:12343 new:1?222 ‘The second cit will lash. Enter the other cilts in the same way. Chauge password: Done ! After entering the last digit, and pressing wel key, the text ‘UGhange password: Done Mwill be displayed. Press the. ey key once. That completes he etn poe Note: For seoutity, the new password should be written into the space provided in chapter 6.1 Man 02-260-08-E 33 VeLIno FT 822 - 823 - 824 FT 922 - 923 - 924 e-escalator Operating manual Faults Attention: Ifa fault occurs, put bartiers around the escalator, and ensure that no tunauthorised person can obstruct the remedying of the fault ‘Thyssenkrupp customer service for rectification or repair. When a fault has occurred, the control panel will display a flashing fault report. ‘The fault report wil give information in plaintext regarding the existing faut and recommend the next step of action. It the recommendation Is to contact customer service, tel them word for word the fault report. 7 “BF Now: tno opr carecty ho caise the tt mb esto. a 1f DEqupment fault, Teleservice active" appears in the display fel, the ‘escalator is connected to a central contcl room. The precise faut report is then cisplayed inthe contol room. Man 02-260-08-E ba ‘on Ver NO FT 822 - 823 - 824, FT 922 - 928 - 924 e-escalator y (Operating manual 7.1 Fault reports ‘The following table lists fault reports, the causes of whieh you can reetity yoursat: Fauleport Fecifcaion of he cause Handrail ile ‘Alosign pay (hes goe ro top left = F253. ‘the specified har inlet. (See. Inspect the palots chapters 2 and 3.7 for deals of andra top area res) Handrail net + Reeve the foreign body! topright Fe = Glose the flaps by pressing both closure Inspect the pallets, levers at the same time: top area Handrail inlet bottom left F40 Inspect the pallets bottom area Handral inet Bottom right £41 Inspect the pallets = Swich the escalator on again. otiom area (see chapter 5:1) Emergecy Stop [Anemeigancy sop bution has been F25 actvated. (29. because people found Emergecy Stop Themselves in a hazardous situation), Oo top 26 Release the people fom the hazardous : Emergecy Stop wae ‘Switch the escalator on again “Top wall F27 (see chapter 5.1) Emergecy Stop bottom © F26 [Emergscy Stop | Bottom wall F2 JEmorgecy Stop Middle» F30 {other reporsy Trforn Thyssenkrupp customer Sone es “al them word for word the fait report, Including noting ard Keeping ready te fault urbe (). fy ) Man 02-260-08-E 35 spas ELINO FT 822 - 823-824 FT 922 - 928-924 e-escalator Operating manual 8 Cleaning To ensure that the escalator operates correctly, it must be regularly cleaned. A Attention: Do not use any caustic, solvent-based or abrasive cleaning agents or polishes. Please: = Switch the escalator off before cleaning. = Make sure no water or other quid penetrates to the inner parts of the escalator. ‘This wil avoid corrosion of components inside the escalator, ~ Plastic surfaces should be cleaned only with soapy water. If other media (e.g. with high alcohol content) are used, the material wil become dull and brit = Painted parts and aluminium surfaces should simply be wiped with a damp cloth and rubbed dry with a cotton cloth, ~ Chrome plated parts should simply be wiped clean using a dry cotton cloth We recommend cleaning at the following intervals: Interval Scope Method Daly Remove din, especialy Pickit up around the éomb plates Weekly (ean the plate glass | Giean with a damp balustrades cloth weeny lean the handralls (Glean with a damp eth Monthy [Giean the grooves inthe palet surface ‘Sweep off wih a broom * Use 2 broom with plastic or natural fibre bristles! Never use a broom with steel brsties. Man 02-260-08-E fa helo Enger ret VeLINO FT 822 - 823 - 824 FT 922-923-924 e-escalator Operating manual Servicing Attention: Casings, covers or electrical switch boves may not be opened other than by trained specialists. ‘Maintenance work or repairs may be carried out only by trained specialists “Thyssenkrupp recommend that this work is carried out by Thyssenkrupp service ‘engineers (see chapter 2). Like any other place of technical equipment, this escalator requires: = proper operation, = regular checking by the operator, + regular maintenance and technical safety checks, ~ when necessary, repair withthe least possible delay. By these measures you will obtain the best availabilty and operational safety from your escalator, They are also your duty under accident prevention regulations, as operator of a escalator. ‘Service comprises checking, which the operator must carry out, plus maintenance ‘and repair, which on the basis of service contracts or service orders may be cartiod ‘out by ThyssenKrupp or on thelr behalt by persons expressly authorised by them, Cheoking ‘Whilst checking, the operator must check the escalator fr obvious defects (see table) IF functional defects or ather deviations from normal operation arse, he must switch off the escalator and inform customer service. The escalator may not be used again uni it thas been repaired. Operation with defective components can cause increased safely hazards and is therefore forbidden, interval [Scope Method Daly Defective indicator lamps, inspection damaged parts, labe's, ]waming signs and deflectors Weekly Damage, breakage Inspection [Weekly (Oil leaks and unusual noises Inspection Man 02-260-08-E 37 ke O Veut NO FT 822 - 823 - 824 FT 922 - 928 - 924 o-escalator Operating manual Oo 9.2 38 Maintenance Escalators contain mechanical components such as chains, bearings, rollers and gears which are subjoct 10 wear during use. After extended operation the wear can ‘such as to affect the safely of the escalator. Correct adjustment of electromechanical and electronic subassemblies is important for their functioning and electrical safety. ‘ThyssenKrupp recommend that maintenance work Is carried out by Thyssenkrupp service engineers, Entering into a service contract with Thyssenkrupp will safeguard the value and safety of your escalator. This will ensure that all necessary maintenance work is cared out at regular intervals, including technical safety checks in the sense of preventative maintenance and necessary adjustments. The period intervals willbe agreed wth ‘Thyssenkrupp having regard to the statutory requirements ‘The maintenance work wil include: ~_ visual checks for completeness, evident damage and defects, together wth crt, sticking parts and wear affecting safely, ~ checks of necessary monitoring, safely, display and reporting devices, @) ~ measurement of parameters relevant for saety, = checks of electrical safety and functionality, ~ for each product further special checks in accordance with generally recognised technical rules, further necessary checks in accordance withthe manufacturer's data. Preventative maintenance is divided into safety check preventative maintenance and safely inspection preventative maintenance: Safety check preventative maintenance includes all work necessary forthe functionality and operational safety ofthe escalator. + Safety inspection preventative maintenance includes additionally the safety technical checks. Safely inspection preventative maintenance must be carried out atleast once a year. Man 02-260-03-E on 9.24 9.2.2 9.3 9.4 VELINO FT 822 - 823-824 FT 922 - 928 -924 e-escalator Operating manual Maintenance intervals Recommended maintenance intervals according to climate table: Glass Indoors [Class I outdoors [Class V, tropios Temperature Her S5C [+2 43°C aT 45°C el hurriity max. 76% Tax. 90% 100% Expose 0 none indirect indirect Dust extreme average Tow exposure exposure to to household dust household dust Sat/granulates7 _|Iow exposure average Tigh exposure to high sand / other humidity at high temperatures Maint. interval SCP [8 months 2 months 2 months Maint. interval SIPM_ [12 months 12 months 12 months To ba conducted Thyssenkrupp customer service Warranty conditional on maintenance The lasting availablity ofa escalator can be guaranteed only if it receives regular and properly carried out maintenance. ‘The warranty contractually agreed for pars fited applies only inthe context of regular performance of maintenance. Repairs Defective components which affect the safety ofthe escalator must be replaced with original spare parts obtainable from customer serve. Record keeping Maintenance and repair work must be recorded, listing the following data: ~ type and scope of work, ~ where necessary data regarding changes to rated values or area of work, ~ date, person undertaking the work, signature. Man 02-260-09-€ paket baa O VeLINo FT 822 - 823 - 824 FT 922 - 923 -924 e-escalator Operating manual Oo 10 Disposal ‘A escalator is a complete self-contained unitary machine, which when fitted with propery mounted covers and when corey cared for poses no hazards to users oro the envionment, Operation of the escalator requires the use of lubricants that are environmentally harmful and therefore must be disposed of correctly in accordance with regulations. ils, greases, olly cleaning cloths and any oily water must not be included in normal industrial or household waste. ‘ThyssenKrupp ~ will be happy to advise you regarding correct disposal of these materials, - and itself retums reusable material to certified disposal points for recycling, thus reducing the burden on our environment, ‘You can have full confidence in ThyssenKrupp customer service. Man 02-260-03-E a ee Eich Pe ee ae ThyssenKrupp Norte, SA. MESSAGE VIEWER USER LEVEL INDICE INTRODUCTION ACCESS. ALARMS MANAGEMENT DATA CHANGES PROCESS ‘SUBMENU CONTROL ‘SUBMENU WATCH NoaeobS NT2S DIAGNOSTIC SYSTEM Rev. 00 ( 08/01/2006 ) Page | of 7 ThyssenKrupp Norte, SA. @) 1.4 INTRODUCTION Introduction ‘The key panel is an optional extra on Avante models. It may be located on the upper left end of the escalator (on the outside, on the opposite side of the balustrade to the start-up key switch and the STOP buttor), on the upper right end of the escalator (on the inside) or in some cases, when requested by the ‘customer, inside the electrical cabinet [| OY AE) The key panel has the following main menus: - STATUS + CONTROL + CLOCK + SETTINGS AND MAINTENANCE The user can access all these menus by using a code, except forthe settings and maintenance menu which requires a special cade end the status menu which does not require any code. Each main menu may in turn include several sub-menu, NT2S DIAGNOSTIC SYSTEM. Rev. 00 ( 08/01/2006 ) Page 2 of 7 ThyssenKrupp Norte, SA. 12 ACCESS Under normal conditions, the following text is displayed, with the system date and time. If*Intro® (enter) is pressed, the display will show the escalators status. Ifthe escalator has a breakdown, the text vill indicate the breakdown. ‘The control unit has a keyboard (6 keys) for user interaction, ‘A description of each key is given below: PREVOUS SDE Move # rou) 8 menus For d any os + To move through the different menus at each level, use the keys “next key — downwards arrow’ or “prev. key — upwards arrow’. This allows you to move to the next menu or submenu, or to the previous one. When in a submenu, press the key "CLR Exit’ to move up a level = _ By pressing the key “Intro® (entes) itis possible to go to the subment directly select the described operation, if possible. = _ Press the keys “side” and up" to change the values of the menu, where possible. = Furthermore, the control panal has two light signals (leds), one red and one green. These leds indicate the escalator’ status, as explained below: = Conlinuous red: escalator in recoverable stop. = Flashing red: escalator breakdown. Continuous green: escalator in use. we are In the main menus, oF to ‘NT2S DIAGNOSTIC SYSTEM Rev. 00 (08/01/2006 ) Page 3 of 7 ThyssenKrupp Norte, SA. 13 ALARMS MANAGEMENT When the escalator bresks down, the screen automatically displays a message indicating the breakdown ‘hat has occurred, This takes priority over any previous message: ‘Once the breakdown has been resolved, follow the aforementioned procedure to go to the menus, Furthermore, the red led will fash if there is @ breakdown and it will be continuously lit up i the stor recoverable. 1.4 DATA CHANGES When data can be changed on a screen (for instance, the password), follow the steps given below: = Pross "Intro" (enter). The text wil start flashi = By using the “up” key, the value ofthe digit where the cursor is located can be Increased one by one. + To move onto the next digit, press the “side” key. The cursor will move to the left. = Toconfirm a value, press the “Intro” key again. The value will be set. NI2S DIAGNOSTIC SYSTEM Rey. 00 ( 08/01/2006 ) Page 4 of 7 oO ThyssenKrupp Norte, SA. Pe ee 18 PROCESS THY SSEN NORTE Eater STATUS ee —{— LOCAL REMOTE haa REVIS Next ee -ASSH continuous toot Th AUTOMATIC in password ‘Automatic ext if the password iat cee has net been entered afer 30 CONTROL seconds Control subme! DATE Baer trol submenu clock Date subme Pe Enter fant j ma veeaE alnenane eben Enter™* * For safety reasons, the password may be changed by our comrrissioning/maintenance staff upon request from the user. " Restricied access by means of special maintenance staff password NT2S DIAGNOSTIC SYSTEM Rev. 00 ( 08/01/2006 ) Page 5 of 7 O TryssenKnapp Norte, SA. 18 CONTROL SUBMENU. By means of this submenu, specific processes regarding the escalator or passenger conveyor status or operation may be adjusted, CONTROL — || Enter 1 DATE }

You might also like