Celda de Carga L6H5

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Type L6H5 Load Cell

Short description

• Aluminium-alloy IP65 single point load cell Test certificate no. TC7839 Revision 0
• Colourless anodized C of C no R60/2000-NL1-10.23
• Suitable for single or double load cell structured
platform scales
• Maximum platform size: 200 x 200 mm

Available models

Capacity Accuracy Full article description


4kg C3 L6H5-C3-4kg-0.5B
5kg C3 L6H5-C3-5kg-0.5B
G
8kg C3 L6H5-C3-8kg-0.5B
10kg C3 L6H5-C3-10kg-0.5B
20kg C3 L6H5-C3-20kg-0.5B
30kg C3 Excluded from OIML L6H5-C3-30kg-0.5B

Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.
Zemic Europe B.V. T: +31 76 50 39480
Leerlooierstraat 8 Nr. 2018.02 L6H5 Rev7 F: +31 76 50 39481
4871 EN Etten-Leur info@zemic.nl
The Netherlands 1/3 www.zemiceurope.com
Type L6H5 Load Cell
Technical specifications L6H5

Accuracy class OIML R60 C3 C3


Output sensitivity ( = FS ) mV/V 2.0 ± 0.2
OIML R60 C3
Maximum capacity ( Emax ) kg 4, 5, 8, 10, 20 30
2.0 ± 0.2
Max. number of load cell intervals nLC 3000
Ratio of min. LC verification interval Y = Emax / vmin 15000
3000
Combined Error %FS ≤± 0.0230
10000
Minimum dead load Of Emax 0%
4000
≤± 0.0175
Safe overload of Emax 150
15000%
5000
Ultimate overload of Emax ≤±300 %
0.0140
20000
Zero balance of FS < ± 2.0 %
Excitation, recommended voltage V 5 ~ 12
Excitation maximum V 18
Input resistance Ω 409 ± 6
Output resistance Ω 350 ± 3
Insulation resistance MΩ ≥5000 ( at 50VDC )
Compensated temperature °C -10 ~+40
Operating temperature °C -35 ~ +65
Storage temperature °C -40 ~ +70
Element material Aluminium
Ingress Protection (acc. to EN 60529) IP65
Recommended torque on fixation Nm M8: 25
bolts
> 30kg: 10

Wiring

Features:
Shielded, 4 conductor cabl.
Cable diameter: Ø3.8mm
Standard cable length: 0.5m
Shield not connected to element
Cable jacket in PVC

4-wire diagram
Input(+) Red

Output(-) White

Input(-) Black
Output(+) Green

Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.
Zemic Europe B.V. T: +31 76 50 39480
Leerlooierstraat 8 Nr. 2018.02 L6H5 Rev7 F: +31 76 50 39481
4871 EN Etten-Leur info@zemic.nl
The Netherlands 2/3 www.zemiceurope.com
Type L6H5 Load Cell
Dimensions in mm

Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.
Zemic Europe B.V. T: +31 76 50 39480
Leerlooierstraat 8 Nr. 2018.02 L6H5 Rev7 F: +31 76 50 39481
4871 EN Etten-Leur info@zemic.nl
The Netherlands 3/3 www.zemiceurope.com

You might also like