Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

A genda

• Broad usage by industry of capillar y


Tubing Retrievable Safety Valve W ells
Can Now Receive A Micro String W ithout • Re-cap of present technologies using capillar y in
conjunction with SCSSV’s.
The Insertion Of AW ireline Insert Valve Or
A W ork-over
• Latest advancements and derivatives.

• Newest technology of capillar y with SCSSV’s


which save time and expense, adds flexibilit y.

Jeff Boldi ng – BJ Dy na-Coil Ser vices

Br oad Usage of Capillary Str ings


QUESTION ??????????

• Land based producers have long benefited from


G iven: That Capillary S trings have had great
the use of capillary string chemical injection.
success on land w ith smaller reserv oir wells.

– Today capillary is the fastest grow ing form of


artificial lift. S houldn’t w e get more dramatic results w ith a
larger pay back, offshore, w ith large reserv oir
wells?
– A total of 10,000 completions in the w orld
w ithin the last 9 years.
But …..these offshore wells and many land
based wells have SCSSV’s

Typical Well Schematic

Safety Valves

&

Ho w Capillary is Integrated

Past and present

1
Running the InjectSafe TM SV and Capillary Tubing
Wireline Retrievable InjectSafe™ Valve
• Lock out the TRSSSV and communicated the hydraulic
piston chamber. The long string is
ferrell connected to the
• The Tubing Retrievable SCSSV is now the equivalent to a injection port
hydraulic nipple.
Suspension slips and a
• Now deploy the “long” Capillary string (SSSV - perfs), load shoulder prevent
connect the InjectSafe valve and deploy to SSSV depth on tensional loads being
wireline. transferred to the
compression fitting

• R/D wireline, R/U Capillary unit and deploy “short” string


though the “Y” body modification on the wellhead and
hang off / terminate.

InjectSafeTM Operation InjectSafeTM Valve With Stinger Insert


InjectSafeTM Valve is Check Valve Injection
run, set, and pulled Mandrel deploye d on
with traditional Capill ary Tubing
wireline tools

InjectSafeTM Valve
Locked into the
SCSSV or Nipple

Stinger Stinger for Surface Control

• The stinger will also r egain “SURFACE


The stinger is used to
CONTROL” for a lost integrity control line.
stab into the PBR on the
short string through the • Storm Chokes or velocity valves are not needed.
“Y” Body • This connection can effectively become the new
control, negating a possible workover.

The PBR receives the


stinger, connected to the
short string

2
Safety V alve and Wellhead Solution
“Y ” Body Design
InjectSafe™ SCSSV Inte gr ates wit h t he
Previously Required existi n g E SD syste m

Wellhead Modifications
Allo ws t he u pp er t ree
valv es to be sh ut wit ho ut
dam ag in g th e Micr o
tub in g

Bottom maste r ca n she ar


Micro str in g if fu ncti on ed

Perf orm anc e cert ifi ed f or


offsho re use p er AP I
6AV1 & AP I 1 4D (A PI
Lic. No. 07 61 )

M icr o-Hanger & sealing off the


Wellhead Solution “Y ” Body Design C hemical Injection Line
Before A top cap protects
Micro-Hanger
the micro string
After

Previous Wellhead Modifications


InjectSafe™ SCSSV
• Obstructed a minimum of one master
Latest Wellhead
valve. Modification Greatly
Improved
• Were cost prohibitive to uni- block
wellheads.

• Obstructed the BPV profile.

3
A Micro-String Hanger Solution for Uni-Block Wellheads
(Back Pressure Thread Capillary Hanger)

This S olution………...

• Avoids the need to straddle the LMGV with Capillary CT

• Requires the flow line / kill line to be raised a few inches

• Means the “Y” Body modification is not required

• Provides the use of a BPV profile.

4
A Micro-String Hanger Solution for Uni-Block Wellheads
(Back Pressure Thread Capillary Hanger)

Recently performed trial was very successful……

BPV MAND REL RUNN ING T OO L AND HANGE R


CHECKING MANDREL THROUGH SPOOL

SPOOL, H ANGER & MANDREL HANGER SPOOL, H ANGER & MANDREL

BPV MANDREL - 3-f t LONG BPV FOR TOP OF BP V M ANDREL

HANGER & RUNNING TOOL FLOW AREA THROUGH HANGER HANGER & RUNNING TOOL FLOW AREA THROUGH HANGER

5
Latest Advancem ents on Capillary
w ith SCSSV’s

• How can you install a capillar y system into a well


without locking out or communicating your
Tubing Retrievable SCSSV?
SPOOL, H ANGER & MANDREL

HANGER & RUNNING TOOL FLOW AREA THROUGH HANGER

Nipple Profile InjectSafe TM


System Typical Hydraulic Nipple

This System
– Negates all wellhead modifications

– Allows micro-string chemical injection to any


depth in the well

– Prevents the need to lock out and


communicate a tubing retrievable safety valve
(SCSSV)

InjectSafe™ Suspe nsion Hanger Com pression Fitting and Slip


Sleeve Window

6
Slip Assem bly Recently Successfully Installed

• This operator had two Hydraulic nipples in


series.
• Both nipples had it’s own dedicated control line
to the nipple
• The lower nipple was used to “suspend” the
capillar y CT to the perforations.
• The Upper nipple received the WRSCSSV

New est Technology Moving


Forw ard Com m unicative Hydraulic Nipple

Selectively communicativ e, Inj ectSafe


Hydraulic Nipples, (Patent Pendi ng).

Nipple w ith Hanger Sleeve


Hydraul ic Nipple Communication Installed
Existing Hydraulics Communication Tool
need to be used by is run into the Well
the Hanger Sleeve

Hydraulics are
opened
Hydraulic Nipp le is
permanently
“Communicated” Hydraulics are
availabl e for the
Hanger Sleeve

7
Selectively com m unicative,
Cut a Way View InjectSafe Hydraulic Nipples ,
Pending) .
(Patent

• Should be installed on all wells Requiring an


SCSSV at time of completion or workover.
• Yields flexibilit y to apply a capillar y string to any
location of the well.
• Is retrievable and replaceable.

All thru-tubing hardware is below the W RSCSSV or


the TRSCSSV.

Thank you for attending… Q uestions ?

You might also like